Maintenance Schedule
Maintenance Schedule
Maintenance Schedule
Filter Maintenance
All filters should be replaced with filters of the original type or with filters that have the
same specifications, otherwise performance of the equipment will be compromised. For
Accudraft original filters please call 800-524-0340.
Pre-Filter – Clean every 50 hours. After every 50 hours of use, remove (pocket filters)
from the air-generating group. Vacuum all accumulated particles. Replace these filters
after 400 hours of use.
Ceiling Filter – Replace every 1200 hours. These filters need to be replaced after a
maximum of 1200 hours of use. Depending on location of the facility and quality of air
being drawn into the system, some of these filters may need to be replaced sooner
than others.
Floor Filter – Replace every 50 hours or when workspace pressure stays above 1 in
the SRAY/WORK cycle and cannot be adjusted any lower. These filters need to be
replaced after 50 hours of use or when the pressure is unable to be lower than 1 (in
SPRAY/WORK period) whichever comes first.
Exhaust Filter – Replace every 50 hours or when workspace pressure stays above 1 in
the SRAY/WORK cycle and cannot be adjusted any lower. Always change Floor Filter
before changing the Filters in the Exhaust Unit.
Burner Maintenance
Every six months a professionally trained technician must tune the burner. For
Accudraft original parts please call 800-524-0340.
Cabin Maintenance