Professional Documents
Culture Documents
Thermal Mass Flow Meters Broch For LFG
Thermal Mass Flow Meters Broch For LFG
FOR INDUSTRY
MASS
PERFORMANCE
productivity, reduce energy costs, and maximize product yields. The Sage FLOW
Metering, Inc. management team has over 100 years of combined experi-
ence in delivering quality in-line and insertion thermal mass flow meters
for a wide variety of industrial needs – and is dedicated to provide you
SUPPORT
with the performance and customer support that you deserve.
SIG–Integral General Purpose WHAT ARE THE BENEFITS THAT SAGE THERMAL
MASS FLOW METERS OFFER YOU?
■ Verify sensor operation and validate calibration with self-check routine
■ Touch Display Screen Technology.The cover does not need to be opened to access
Menuing System (actual changes are password protected and accessible
by authorized personnel only).
■ Lead-Length Compensation.Remote electronics up to 1000 feet from probe
■ Probe Junction Box requires no electronics.Suitable for harsh environments
■ Available with up to four totally independent calibrations (four different gases,
sensitivities, or configurations). Channels A–D selectable by keypad, laptop or
external switch closure
■ Powerful microprocessor technology designed for high performance mass flow
measurement and field rangeability
■ Proprietary sensor drive circuit provides enhanced signal stability and provides
extraordinary temperature compensation
■ Menu driven user configurability, including full scale setting, units of measure, pipe
SRG–Remote General Purpose area, channel selection, and diagnostics
■ Easy to read 2-line back-lit flow rate/totalizer and temperature display. Also serves
as dialog window for menu selection of user options
■ RS232 PC interface and free navigational software (Sage VIP) – user friendly
■ Flow conditioning built in to in-line flow meters (3/4 inch and up)
■ Choice of explosion proof or general purpose, integral or remote electronics
■ User-selectable relays (Trip High, Low or Pulsed Outputs) – standard on Industrial
product, optional on General Purpose (GP) product
GENERAL
■ Function: Microprocessor-based Insertion or In-Line Mass
Flow Meters for gases
LBS/D, SLPM, SLPH; Velocity– SFPM, SFPS, NMPM, NMPS, NMPH
(other combinations available); Temperature–°C and °F
■ Insertion Meters: Full Scale up to 35,000 SFPM (i.e.,
are blind.) Keypad uses Touch Display Screen Technology on
General Purpose Meters (SIG & SRG) and can be activated
without removing cover.
■ Flow Element: Constant Temperature Thermal Mass Flow up to 12,000 SCFM in an 8" Sch. 40 Pipe). Higher velocities
WETTED PARTS
Element consists of two 316 SS clad platinum-wound RTDs optionally available. Resolve as low as 10 SFPM. Standard probe
■ Flow Rate Output Signal 7: 4-20mA isolated linear flow signal
316L Stainless Steel for Flow Bodies, Sensor Flow Elements
is 1/2" diameter, with optional 3/4". Standard lengths are
on all products. Pulsed outputs optional 8 6", 12", 15", 18" or 24" and optional up to 48" and Flow Conditioners. Hastelloy (recommended for Chlorine
■ Temperature Output Signal7: 4-20mA isolated linear tem- ■ In-Line Meters: Full Scale up to 3150 SCFM (4" Flow Meter).
Gas) and other materials optional.
perature signal from 40°F to 200°F (-40°F to 750°F optional) is Resolve as low as .003 SCFM (1/4" Flow Meter). Male NPT FLOW CONDITIONING
second output on SIG & SRG Series; menu selectable in lieu of fittings standard. 150# and 300# flanged ends optional. All In-Line Flow Meters 3/4 inch and above include built-in flow
flow outputs on SIE & SRE Series. A second temperature output is (See chart below) conditioning.
also available on the SIL and SRL Series, but it is 0–5VDC linear PERFORMANCE AGENCY APPROVALS
instead of 4–20mA ■ Standard Flow Accuracy 6: +/-1% of Reading +0.5% of Full
■ Pulsed Outputs9: Pulsed Outputs of Totalized Flow is soft-
UL. Contact Sage or visit our website (www.sagemetering.com)
Scale over 100:1 turndown.(Contact Sage for special accuracy) for details.
ware configurable on the SIL and SRL Series; Configurable off of ■ Repeatability: 0.2% of Full Scale
the SIE and SRE Series Relay; and Configurable with optional ■ Turndown: 100:1 of Full Scale minimum (1000:1 with
ETHERNET COMPATIBILITY
Relays on the SIG and SRG Series Pending. Contact Sage or visit our website (www.sagemeter-
multiple channels)
■ Relays: Two 1-amp relay channels (each SPDT) optionally ing.com) for details.
■ Calibration: Sage Metering’s National Institute of Standards
available on SIG & SRG Series. One 1-amp relay is standard on SIE Traceable (NIST) calibration facility LIMITED WARRANTY
& SRE Series. Menu configurable (see description under Sage ■ Gas Temperature11: Std.: -40°F to 200°F (-40°C to 93°C );
Thermal Mass Flow Meters on page 3). Sage Metering's Series of Thermal Mass Flow Meters are war-
HTO1: 200°F to 350°F (93°C to 177°C ); HTO2: 350˚F to 500˚F ranted against faulty materials or workmanship for one year
■ Communication: RS232. (Ethernet pending)
■ Sensor Drive Circuit: Proprietary Sensor Drive Circuit provides
(177˚C to 260˚C); HTO3: 500˚F to 750˚F (260˚C to 399˚C) from the date of delivery to the buyer. After issuance of a Return
■ Integral or Remote Enclosure Temperature: 0° to 150°F Meter Authorization (RMA) by Sage, and upon receipt of the
enhanced flow signal stability and insensitivity to process tem-
(-18°C to 65°C ). Contact Sage for lower temperature ranges. defective meter, Sage will either repair or replace the defective
perature changes
■ Display: 2-line LCD back-lit Flow Rate (top line),Total and
Note: Remote Enclosure can be mounted up to 1000 feet away meter at its sole option and at no cost to the purchaser.
from sensor and its Junction Box in order to be located in a suit-
Temperature (bottom line) is standard on all Mass Flow Meters
able temperature environment
(except for SIL and SRL Series which have no displays)
■ Junction Box Temperature: Suitable for harsh environments
■ Menu Navigation: 4-Button Touch Display Screen8 Keypad
(except SIL & SRL) and RS232 with navigational software (Sage – contains no electronics PLEASE NOTE
■ Pressure Rating: 500 psig (1000 psig optional)
VIP) standard (software optional on SIL & SRL).With Touch Performance specifications are effective with date
■ Response Time: 1 second (each time constant) for flow change
Display Screen technology, the cover does not need to be opened of issue and are subject to change without prior
■ Subsystem Interface: Full duplex digital using SLIP protocol
to access Menuing System. notice.The metering devices and other equipment
■ Multiple Channel Capability: Up to four totally independent ENCLOSURES
Integral General Purpose, Integral Explosion Proof, Remote
pictured in this brochure are for identification and
calibrations available on all products except SIL & SRL. Calibrate
for four different gases, different sensitivities, and/or different General Purpose, and Remote Explosion Proof. Remote styles illustration purposes only.The appearance and
configurations (Channels A–D). Channels can be keypad, laptop do not require electronics at sensor Junction Box and can be dimensions of the actual products may differ slightly
or externally selectable (via contact closures). located up to 1000 feet away from the sensor.(See dimensional from those shown but will perform as represented.
■ Power: 24VDC (250 ma with back light off, 350mA max with drawings on page 5 for classifications.) Sage Metering, Inc. reserves the right, at any time,
back light on),115VAC or 230VAC (Switchable) on SIG & SRG Series. DISPLAY / KEYPAD to make such modifications and changes to the
250mA max on SIE, SRE, SIL or SRL Series General Purpose SIG & SRG Transmitter have large format 2 x 16 products shown herein as it deems appropriate,
FLOW RANGE / SIZES LCD back-lit display with large format 4-Button Keypad. Explo-
■ Units of Measurement: Flow–SCFM, SCFH, SCFD, SCCM,
without prior notice to the customer.
sion Proof SIE & SRE Transmitter has 2 x 16 small format back-lit
NCMM, NCMH, KG/S, KG/M, KG/H, KG/D, LBS/S, LBS/M, LBS/H, display with standard 4-Button Keypad. (SIL & SRL transmitter
Expl. Proof
(B)
Pipe
Size
Gen. Purpose
(A)
Expl. Proof
(B)
DISPLAY
flanged mounting is optionally available. 4.69 In-Line Style1, 7
Available probe lengths (C) are 6", 12", 15", B Explosion Proof Enclosure (Cast Aluminum).
17.50
18", 24", 30", 36" or 48". Class I, Division I, Group B, C, D. 150# or 300#
C flanged ends are optionally available.
8.00
(1" Flow Body shown)
4.50
7.94 SIE SERIES INTEGRAL EXPLOSION PROOF12
5.31
MASS FLOW METER
DISPLAY
4.96 9.30
SRG SERIES REMOTE GENERAL PURPOSE 4.69 Insertion Style2, 7
MASS FLOW METER15 Explosion Proof Enclosure (Cast Aluminum).
7.31 Insertion Style2, 8, 9 Class I, Division I, Group B, C, D. 150# or 300#
(Also available as In-Line Style) flanged mounting is optionally available.
NEMA 4X Enclosure (Fiberglass14). 150# or 300# 17.10 Available probe lengths (C) are 6", 12", 15",
CONDUIT flanged mounting is optionally available. C 18", 24", 30", 36" or 48".
HUB
Available probe lengths (C) are 6", 12", 15",
18", 24", 30", 36" or 48".
25' CABLE SUPPLIED
3.00 dia Can be shortened or even
lengthened in the field
by up to 1000' without
JUNCTION BOX (XP1) affecting calibration
Explosion Proof 4.50 SRE SERIES REMOTE EXPLOSION PROOF 12
(Cast Aluminum)
(No Electronics Required) MASS FLOW METER
4.69 In-Line Style1, 7
SRL SERIES REMOTE LITE (BLIND) 25' CABLE SUPPLIED (Also available as Insertion Style)
5.00
Can be shortened or Explosion Proof Enclosure (Cast Aluminum).
MASS FLOW METER even lengthened
5.00 Insertion Style2, 8, 9, 10 in the field by Class I, Division I, Group B, C, D. 150# or 300#
up to 1000' with-
(Also available as In-Line Style) 3.00 dia. out affecting flanged ends are optionally available.
calibration (1" Flow Body shown)
NEMA 4X Enclosure (ABS Plastic). 150# or 300#
flanged mounting is optionally available. JUNCTION BOX (XP1) (Mounting Bracket is included)
CORD GRIP Explosion Proof
COMPRESSION Available probe lengths (C) are 6", 12", 15", (Cast Aluminum)
FITTING (No Electronics
3.00 dia 18", 24", 30", 36" or 48". 8.00 Required)
25' CABLE SUPPLIED
Can be shortened or even
lengthened in the field
by up to 1000' without SVA SERIES ISOLATION VALVE ASSEMBLY
affecting calibration SAFETY CHAIN5 MOUNTING HARDWARE FOR
INSERTION METERS 13
4.50 COMPRESSION FITTING
SIL SERIES INTEGRAL EXPLOSION PROOF12 10.004 The Isolation Valve Assembly permits insertion
(BLIND) MASS FLOW METER or removal of probe without shutting down
4.69
In-Line Style1, 8 ISOLATION VALVE
B the gas line.
(Also available as Insertion Style) 3/4" WELD-LET
2.55
Explosion Proof Enclosure (Cast Aluminum), Class I,
Division I, Group C, D. 150# or 300# flanged ends
8.00
are optionally available. (1" Flow Body shown) STCF SERIES TEFLON FERRULE COMPRESSION
FITTING MOUNTING HARDWARE
1/2" tube x 1/2" pipe fitting (shown, not to
1 NPT Fittings standard (150# or 300# flanges optional) 11 When flanges specified, face-to-face dimensions same as 1.92
1.92 scale), is used for low pressure insertion appli-
2 Flanged Mounting available for high pressure operation Length on Table on page 4. cations to 125 psig (Stainless Steel Ferrule
4 10" nominal when collar clamps are together 12 All Explosion Proof Meters are Class I, Group B, C, D, Class II
5 Safety chain is sized depending on probe length to Group E, F, G and Class IV and have Cenelec, EExd Enclosure optional for higher pressure applications –
prevent probe from escaping above compression fitting. IIC, IP66 ratings and are NEMA 4X, 7BCD and 9EFG rated. up to 225 psig). Also available in 3/4" tube x
6 At 650 psig,force exerted on 1⁄2 diameter probe is approx. (All Junction Boxes, when applicable, are Class I, Group C
125 psig. & D; Class II, Group E, F, G, and NEMA 7 and NEMA 9 rated.) 3/4" pipe size.
7 3/4" Female NPT access holes for wiring (conduit 13 Used for pressures to 650 psig (shown for use with 1⁄2" x
3
compatible) ⁄4" NPT and 3⁄4" x 1" NPT.
8 Access holes are 1⁄2" NPT (supplied capped) 14 Other materials available
9 All NEMA 4X Enclosures have 4" depth 15 NOTE: Only one Conduit Hub is supplied, and one Cord
10 Circuit board available separately, 3" diameter. Grip is supplied with SRG Series.
1/4”
Sage In-Line Meters
S( _ _ )-025
Sage Insertion Meters
N/A
Building a Model Number
1. Select Style
■ Integral (I) or Remote (R)
■ General Purpose (G), Explosion Proof (E) or Sage Lite (L)
3/8” S( _ _ )-030 N/A ■ In-Line (-XXX) or Insertion (-XX-XX)
2. If In-Line, select pipe size (see table on page 4 for Flow Body Length)
1/2” S( _ _ )-050 N/A
3. If Insertion, select probe diameter, and length
3/4” S( _ _ )-075 N/A ■ [(-05 = 1/2" tube (standard); -07 = 3/4" tube (optional)]
S( _ _ )-100 4. Select probe length based on mounting hardware choice (the chart assumes
1” S( _ _ )-05-12 utilizing Sage Isolation Valve Assembly mounting hardware)
S( _ _ )-125 ■ -12 = 12" length; -15 = 15" length
1-1/4" S( _ _ )-05-12
■ -18 = 18" length; -24 = 24" length; -30 = 30" length
1-1/2” S( _ _ )-150 S( _ _ )-05-12 ■ -06 = 6" length (assumes utilizing Sage Teflon Compression Fitting
mounting hardware)
2” S( _ _ )-200 S( _ _ )-05-15
5. If Insertion, select mounting hardware (Valve or Compression Fitting)
2-1/2" S( _ _ )-250 S( _ _ )-05-15 ■ SVA05 = Sage Isolation Valve Assembly for 1/2" probe
■ SVA07 = Sage Isolation Valve Assembly for optional 3/4" probe
3” S( _ _ )-300 S( _ _ )-05-15 ■ STCF05 = Sage Teflon Compression Fitting for 1/2" probe
■ SSCF05 = Sage Stainless Steel Compression Fitting for 1/2" probe
4” S( _ _ )-400 S( _ _ )-05-15 ■ STCF07 = Sage Teflon Compression Fitting for optional 3/4" probe
6”-14” N/A S( _ _ )-05-18 6. Select operating voltage: -DC24 = 24VDC; -AC115 = 115VAC;
-AC230 = 230VAC
16”-24” N/A S( _ _ )-05-24 7. Add symbol of gas being measured at end of part number
26”-36” N/A S( _ _ )-05-30 8. Add Options (such as RG2: Dual Range; HTO1 = High Temperature Operation)
9. Include Full Scale Flow Rate and operating temperature and pressure
>36” N/A Consult Factory in description
currently offered by
including General
SIG-XXX SIG-XX-XX SRG-XXX SRG-XX-XX
Purpose, Explosion
INTEGRAL EXPLOSION PROOF REMOTE EXPLOSION PROOF
Proof and Remote
IN-LINE INSERTION IN-LINE INSERTION
Configurations.
Rev. 0806