SAGE GAS MASS FLOW METERS

FOR INDUSTRY

Make the Wise Choice. Choose Sage Flow Meters.


DEDICATION
Sage Metering, Inc. is your source for monitoring, measuring and con-
trolling the gas mass flow in your industrial process. Our high perform-
ance, NIST traceable, thermal mass flow meters will help you increase
QUALIT Y

MASS
PERFORMANCE

productivity, reduce energy costs, and maximize product yields. The Sage FLOW
Metering, Inc. management team has over 100 years of combined experi-
ence in delivering quality in-line and insertion thermal mass flow meters
for a wide variety of industrial needs – and is dedicated to provide you
SUPPORT
with the performance and customer support that you deserve.

HOW DOES THERMAL MASS FLOW


MEASUREMENT BENEFIT YOU?
■ Direct Mass Flow – No need for separate temperature or pressure transmitters
■ High Accuracy and Repeatability – Precision measurement and optimal control
of your process
■ Rangeable over 100:1 Turndown (1000:1 with multiple calibrations)
Accommodates the extremes of your process with one instrument
■ Extreme Low-End Sensitivity – Detects leaks, and measures flow, even on start-up
(measures as low as 10 SFPM)
■ Negligible Pressure Drop – Will not impede the flow nor waste energy
■ No Moving Parts – Eliminates costly bearing replacements, and prevents
undetected accuracy shifts
■ Dirt Insensitive – Rugged stainless steel sensors provide sustained performance
■ Ease of installation, and convenient mounting hardware

SIG–Integral General Purpose WHAT ARE THE BENEFITS THAT SAGE THERMAL
MASS FLOW METERS OFFER YOU?
■ Verify sensor operation and validate calibration with self-check routine
■ Touch Display Screen Technology.The cover does not need to be opened to access
Menuing System (actual changes are password protected and accessible
by authorized personnel only).
■ Lead-Length Compensation.Remote electronics up to 1000 feet from probe
■ Probe Junction Box requires no electronics.Suitable for harsh environments
■ Available with up to four totally independent calibrations (four different gases,
sensitivities, or configurations). Channels A–D selectable by keypad, laptop or
external switch closure
■ Powerful microprocessor technology designed for high performance mass flow
measurement and field rangeability
■ Proprietary sensor drive circuit provides enhanced signal stability and provides
extraordinary temperature compensation
■ Menu driven user configurability, including full scale setting, units of measure, pipe
SRG–Remote General Purpose area, channel selection, and diagnostics
■ Easy to read 2-line back-lit flow rate/totalizer and temperature display. Also serves
as dialog window for menu selection of user options
■ RS232 PC interface and free navigational software (Sage VIP) – user friendly
■ Flow conditioning built in to in-line flow meters (3/4 inch and up)
■ Choice of explosion proof or general purpose, integral or remote electronics
■ User-selectable relays (Trip High, Low or Pulsed Outputs) – standard on Industrial
product, optional on General Purpose (GP) product

MULTIPLE CHANNEL CAPABILITY


■ Four different gas calibrations in one meter (optional)
■ Switch channels to switch sensitivities for greater than 1000 to 1 turndown
(Channel A: 0-10 SCFM; Channel B: 0-100 SCFM, etc. – externally selectable) – Ideal
for Flare Gas applications
■ Pre-configure for four different pipe sizes and full scale flow rates (i.e.: 2", 4”, 6”, 8")
■ One meter can be a spare for dozens of differing applications: Simply select from
SIE–Integral Explosion Proof four gas calibrations, enter pipe area, and enter full scale

{2} SAGE METERING, INC.


QUALITY
SAGE THERMAL MASS FLOW METERS

Sage Thermal Mass Flow Meters are designed for


high performance mass flow measurement of flow
meters provide the average flow rate for the prior
hour at any time. If you require relay outputs,
rate and consumption of gases such as air, oxygen, Sage offers the option of two independent, 1 amp
natural gas, nitrogen, digester gas, bio gas, flare gas, SPDT relays on the SIG and SRG Series that can
hydrogen, argon, carbon dioxide and other gases be configured by laptop or keypad for a variety
and gas mixes.They are field rangeable and have of settings (one relay is standard on the SIE or SRE
a convenient user interface. Series), including trip-high, trip-low (with or
without delays), window alarms, pulsed outputs,
FEATURES AND BENEFITS timer outputs, etc.
The innovative Sage design features an easy-to-use The Series SRG includes a more robust latched
menuing system, a large format mass flow, total and 9.3"x7.3" Fiberglass Windowed Remote Enclosure
temperature display, and easy-to-use,Touch Display that can be mounted 1000 feet away from the
Screen, 4-button keypad to integrate the functions sensor’s measurement point.The 6-conductor
of flow measurement with your specific needs. cable separating the sensor probe (or flow body)
You will have the flexibility to use the local display/ from the electronics is lead-length compensated,
keypad, or a laptop, to change configurations or to allowing the user to change wire length without
conduct basic diagnostics, including a calibration affecting the meter’s accuracy or performance.
PRINCIPLE OF OPERATION OF
self-check, with the Sage navigational software In addition, the probe has an Explosion Proof
THE THERMAL MASS FLOW METER
Sage Thermal Mass Flow Meters have two sensors
(Sage VIP).At any time you can use the convenient Junction Box that does not require any electronics
constructed of reference grade platinum windings
menuing system to change full scale values, digitally (all the electronics, as well as the meter display
(RTDs).The two RTDs are clad in a protective 316SS
filter the flow signal, change decimal points, set zero and menuing Touch Display Screen keypad, are in
sheath and are driven by a proprietary sensor drive
cutoffs, check diagnostics, or reconfigure an insertion the Remote Enclosure).Thus, this easy-to-wire
circuit. One sensor is self-heated (flow sensor), and
meter for a different pipe size. Junction Box is suitable for harsh environments
the other (temperature/reference sensor) measures
In addition, you can order your meter configured (see photo on page 2).
gas temperature.The pair is referred to as the sens-
for up to four different gas calibrations, and simply Sage also offers an OEM version of our proven,
ing element, and is either installed in a probe as an
select the desired channel (A-D) at any time (e.g. high performance gas mass flow meter product line
Insertion style, or inserted into a pipe section as an
four different gases, sensitivities, or configurations). (Series SIL or SRL). “Sage Lite” has many features
In-Line style flow meter. As gas flows by the flow
Or you can order the meter calibrated for one gas of the standard product line, but does not have a
sensor, the gas molecules carry heat away from the
(e.g. compressed air), but have it pre-configured for display, does not have a menuing keypad, does not surface, and the sensor cools down as it loses ener-
up to four different pipe sizes and full scales, so you support multiple channels, and does not support gy.The sensor drive circuit replenishes the lost ener-
can simply select the desired channel (A-D) based relay outputs. However it has linear outputs of flow gy by heating the flow sensor until it is a constant
on the application. Channels are totally independent rate and temperature, and is configurable to have temperature differential above the reference sensor.
and each have their own full scale accuracy state- one output that provides pulsed outputs of totalized The electrical power required to maintain a constant
ment and settings. flow. It is offered in a 5x5x4 NEMA 4X temperature differential is directly proportional to
There are numer- enclosure, or Explosion the gas mass flow rate and is linearized to be the
ous other features Proof Enclosure, or as a output signal of the meter.
built in to most single circuit board for It is essential that this constant temperature
Sage Flow Meters. customized end-user differential be maintained, even if there are wide
For example, continu- packaging. fluctuations in gas temperature. It is the “job”of
ous tracking of the If there are any features the Sage proprietary sensor drive circuit to maintain
highest and lowest that you require, or if you the differential, whether or not the gas temperature
mass flow rate with need application assistance, changes, or however quickly molecules cool off the
built in time and date feel free to contact our local flow sensor. It is also necessary to properly calibrate
stamps.This is a very factory trained representative the device with the actual gas (or close equivalent
practical feature for in your area.Visit us online at with certain gases),in the Sage National Institute of
determining unusual www.sagemetering.com, Standards certified (NIST) calibration facility. By ac-
peaks in a gas process, or telephone someone in complishing these two critical objectives, the Sage
or for identifying ex- the Sage Sales or Service meters provide an extremely repeatable (0.2% of
cess usage by certain SIG Series Integral General Purpose Mass Flow Meter Staff for assistance at full scale) and accurate output directly proportional
departments.Sage (In-Line Style shown). (866-677-7243). to the mass flow rate of the gas being measured.

SAGE METERING, INC. {3}


SPECIFICATIONS
GENERAL SPECIFICATIONS FOR SAGE MASS FLOW METERS

GENERAL
■ Function: Microprocessor-based Insertion or In-Line Mass
Flow Meters for gases
LBS/D, SLPM, SLPH; Velocity– SFPM, SFPS, NMPM, NMPS, NMPH
(other combinations available); Temperature–°C and °F
■ Insertion Meters: Full Scale up to 35,000 SFPM (i.e.,
are blind.) Keypad uses Touch Display Screen Technology on
General Purpose Meters (SIG & SRG) and can be activated
without removing cover.
■ Flow Element: Constant Temperature Thermal Mass Flow up to 12,000 SCFM in an 8" Sch. 40 Pipe). Higher velocities
WETTED PARTS
Element consists of two 316 SS clad platinum-wound RTDs optionally available. Resolve as low as 10 SFPM. Standard probe
■ Flow Rate Output Signal 7: 4-20mA isolated linear flow signal
316L Stainless Steel for Flow Bodies, Sensor Flow Elements
is 1/2" diameter, with optional 3/4". Standard lengths are
on all products. Pulsed outputs optional 8 6", 12", 15", 18" or 24" and optional up to 48" and Flow Conditioners. Hastelloy (recommended for Chlorine
■ Temperature Output Signal7: 4-20mA isolated linear tem- ■ In-Line Meters: Full Scale up to 3150 SCFM (4" Flow Meter).
Gas) and other materials optional.
perature signal from 40°F to 200°F (-40°F to 750°F optional) is Resolve as low as .003 SCFM (1/4" Flow Meter). Male NPT FLOW CONDITIONING
second output on SIG & SRG Series; menu selectable in lieu of fittings standard. 150# and 300# flanged ends optional. All In-Line Flow Meters 3/4 inch and above include built-in flow
flow outputs on SIE & SRE Series. A second temperature output is (See chart below) conditioning.
also available on the SIL and SRL Series, but it is 0–5VDC linear PERFORMANCE AGENCY APPROVALS
instead of 4–20mA ■ Standard Flow Accuracy 6: +/-1% of Reading +0.5% of Full
■ Pulsed Outputs9: Pulsed Outputs of Totalized Flow is soft-
UL. Contact Sage or visit our website (www.sagemetering.com)
Scale over 100:1 turndown.(Contact Sage for special accuracy) for details.
ware configurable on the SIL and SRL Series; Configurable off of ■ Repeatability: 0.2% of Full Scale
the SIE and SRE Series Relay; and Configurable with optional ■ Turndown: 100:1 of Full Scale minimum (1000:1 with
ETHERNET COMPATIBILITY
Relays on the SIG and SRG Series Pending. Contact Sage or visit our website (www.sagemeter-
multiple channels)
■ Relays: Two 1-amp relay channels (each SPDT) optionally ing.com) for details.
■ Calibration: Sage Metering’s National Institute of Standards
available on SIG & SRG Series. One 1-amp relay is standard on SIE Traceable (NIST) calibration facility LIMITED WARRANTY
& SRE Series. Menu configurable (see description under Sage ■ Gas Temperature11: Std.: -40°F to 200°F (-40°C to 93°C );
Thermal Mass Flow Meters on page 3). Sage Metering's Series of Thermal Mass Flow Meters are war-
HTO1: 200°F to 350°F (93°C to 177°C ); HTO2: 350˚F to 500˚F ranted against faulty materials or workmanship for one year
■ Communication: RS232. (Ethernet pending)
■ Sensor Drive Circuit: Proprietary Sensor Drive Circuit provides
(177˚C to 260˚C); HTO3: 500˚F to 750˚F (260˚C to 399˚C) from the date of delivery to the buyer. After issuance of a Return
■ Integral or Remote Enclosure Temperature: 0° to 150°F Meter Authorization (RMA) by Sage, and upon receipt of the
enhanced flow signal stability and insensitivity to process tem-
(-18°C to 65°C ). Contact Sage for lower temperature ranges. defective meter, Sage will either repair or replace the defective
perature changes
■ Display: 2-line LCD back-lit Flow Rate (top line),Total and
Note: Remote Enclosure can be mounted up to 1000 feet away meter at its sole option and at no cost to the purchaser.
from sensor and its Junction Box in order to be located in a suit-
Temperature (bottom line) is standard on all Mass Flow Meters
able temperature environment
(except for SIL and SRL Series which have no displays)
■ Junction Box Temperature: Suitable for harsh environments
■ Menu Navigation: 4-Button Touch Display Screen8 Keypad
(except SIL & SRL) and RS232 with navigational software (Sage – contains no electronics PLEASE NOTE
■ Pressure Rating: 500 psig (1000 psig optional)
VIP) standard (software optional on SIL & SRL).With Touch Performance specifications are effective with date
■ Response Time: 1 second (each time constant) for flow change
Display Screen technology, the cover does not need to be opened of issue and are subject to change without prior
■ Subsystem Interface: Full duplex digital using SLIP protocol
to access Menuing System. notice.The metering devices and other equipment
■ Multiple Channel Capability: Up to four totally independent ENCLOSURES
Integral General Purpose, Integral Explosion Proof, Remote
pictured in this brochure are for identification and
calibrations available on all products except SIL & SRL. Calibrate
for four different gases, different sensitivities, and/or different General Purpose, and Remote Explosion Proof. Remote styles illustration purposes only.The appearance and
configurations (Channels A–D). Channels can be keypad, laptop do not require electronics at sensor Junction Box and can be dimensions of the actual products may differ slightly
or externally selectable (via contact closures). located up to 1000 feet away from the sensor.(See dimensional from those shown but will perform as represented.
■ Power: 24VDC (250 ma with back light off, 350mA max with drawings on page 5 for classifications.) Sage Metering, Inc. reserves the right, at any time,
back light on),115VAC or 230VAC (Switchable) on SIG & SRG Series. DISPLAY / KEYPAD to make such modifications and changes to the
250mA max on SIE, SRE, SIL or SRL Series General Purpose SIG & SRG Transmitter have large format 2 x 16 products shown herein as it deems appropriate,
FLOW RANGE / SIZES LCD back-lit display with large format 4-Button Keypad. Explo-
■ Units of Measurement: Flow–SCFM, SCFH, SCFD, SCCM,
without prior notice to the customer.
sion Proof SIE & SRE Transmitter has 2 x 16 small format back-lit
NCMM, NCMH, KG/S, KG/M, KG/H, KG/D, LBS/S, LBS/M, LBS/H, display with standard 4-Button Keypad. (SIL & SRL transmitter

Pipe Size x 10 Minimum Resolution10 Typical FS3 Max FS4


Flow Body Length1 or Model 2 (Standard Cubic Feet (Standard Cubic Feet (Standard Cubic Feet
Flange (Face-to-Face) per Minute5) per Minute5) per Minute5)
1/4" x 6" S( _ _ )-025 0.003 3 8
3/8" x 6" S( _ _ )-030 0.006 6 15
1/2" x 7" S( _ _ )-050 0.013 13 30
3/4" x 7" S( _ _ )-075 0.06 60 140
1" x 8" S( _ _ )-100 0.09 90 200
1-1/4" x 10" S( _ _ )-125 0.15 150 300
1-1/2" x 12" S( _ _ )-150 0.20 200 470
2"xx15"
2" 15" S( _ _ )-200 0.35 350 820
2-1/2" x 18" S( _ _ )-250 0.50 500 1000
3" x 20" S( _ _ )-300 0.75 750 1750
4" x 25" S( _ _ )-400 1.35 1350 3150
1 Flow Conditioning Built in to Flow Meter Pipe Sizes 3/4" and up. Contact Sage for optional 1/4" tube flow body 6 At zero or low flow, meter(s) may experience a slight pressure sensitivity
2 (_ _) determined by Meter style and enclosure (i.e., SRG: Remote Style, General Purpose Enclosure) 7 The SIL & SRL Series has two outputs, a 4-20mA and a 0-5VDC signal. They each can be configured for either
3 Full Scale (FS) can be specified as low as 1/10 of typical full scale to retain 100:1 turn down. flow or temperature
For example, a 3/4" Meter can be specified as high as 0-140 SCFM, or as low as 0-6 SCFM, or anything in 8 Touch Display Screen not available on SIE or SRE Series
between (i.e., 0-40 SCFM) 9 The SIL and SRL Series pulses drive loads not to exceed 20 ma (e.g.,TTL logic, opto-isolators and low power
4 Max Full Scale available for many gases, such as pressurized Air or Nitrogen. Some gases such as Hydrogen may relays), however, the pulsed outputs on the SIE, SRE, SIG and SRG Series drive 1 amp Relays). See RELAYS
be limited to the Typical FS value.Calibrations above 500 SCFM may be extrapolated. 10 Minimum Resolution based on 15 SFPM, but can be resolved as low as 5 SFPM
5 1 SCFM = 1.7 NCMH. Sage standard conditions for calibration are 70˚F and 29.92" Hg. 11 HTO1, HTO2, and HTO3 options apply to Insertion Meters only

{4} SAGE METERING, INC.


DETAIL DIMENSIONAL DRAWINGS FOR SAGE MASS FLOW METERS
Note: Flanged Flow Bodies Optional 11
(All Dimensions in Inches)
7.00 4.00 SIG SERIES INTEGRAL GENERAL PURPOSE
Pipe
Size
Gen. Purpose
(A)
IN-LINE METER DIMENSIONS
Flow Body Length Shown on Page 4

Expl. Proof
(B)
Pipe
Size
Gen. Purpose
(A)
Expl. Proof
(B)

MASS FLOW METER 1/4" 8.03" 7.33" 1-1/2" 8.65" 7.95"


5.03
In-Line Style1, 8, 9 3/8" 8.09" 7.39" 2" 8.90" 8.20"
A NEMA 4X Enclosure (ABS Plastic). 150# or
1/2" 8.15" 7.45" 2-1/2" 9.15" 8.45"
300# flanged ends are optionally available.
(1" Flow Body shown) 3/4" 8.28" 7.58" 3" 9.40” 8.70"
8.00 1" 8.40" 7.70" 4" 9.90" 9.20"
1-1/4" 8.53" 7.83"
7.00 4.00
SIG SERIES INTEGRAL GENERAL PURPOSE
MASS FLOW METER
5.03 Insertion Style2, 8, 9 7.94 SIE SERIES INTEGRAL EXPLOSION PROOF12
4.50 5.31
NEMA 4X Enclosure (ABS Plastic). 150# or 300# MASS FLOW METER

DISPLAY
flanged mounting is optionally available. 4.69 In-Line Style1, 7
Available probe lengths (C) are 6", 12", 15", B Explosion Proof Enclosure (Cast Aluminum).
17.50
18", 24", 30", 36" or 48". Class I, Division I, Group B, C, D. 150# or 300#
C flanged ends are optionally available.
8.00
(1" Flow Body shown)

4.50
7.94 SIE SERIES INTEGRAL EXPLOSION PROOF12
5.31
MASS FLOW METER

DISPLAY
4.96 9.30
SRG SERIES REMOTE GENERAL PURPOSE 4.69 Insertion Style2, 7
MASS FLOW METER15 Explosion Proof Enclosure (Cast Aluminum).
7.31 Insertion Style2, 8, 9 Class I, Division I, Group B, C, D. 150# or 300#
(Also available as In-Line Style) flanged mounting is optionally available.
NEMA 4X Enclosure (Fiberglass14). 150# or 300# 17.10 Available probe lengths (C) are 6", 12", 15",
CONDUIT flanged mounting is optionally available. C 18", 24", 30", 36" or 48".
HUB
Available probe lengths (C) are 6", 12", 15",
18", 24", 30", 36" or 48".
25' CABLE SUPPLIED
3.00 dia Can be shortened or even
lengthened in the field
by up to 1000' without
JUNCTION BOX (XP1) affecting calibration
Explosion Proof 4.50 SRE SERIES REMOTE EXPLOSION PROOF 12
(Cast Aluminum)
(No Electronics Required) MASS FLOW METER
4.69 In-Line Style1, 7
SRL SERIES REMOTE LITE (BLIND) 25' CABLE SUPPLIED (Also available as Insertion Style)
5.00
Can be shortened or Explosion Proof Enclosure (Cast Aluminum).
MASS FLOW METER even lengthened
5.00 Insertion Style2, 8, 9, 10 in the field by Class I, Division I, Group B, C, D. 150# or 300#
up to 1000' with-
(Also available as In-Line Style) 3.00 dia. out affecting flanged ends are optionally available.
calibration (1" Flow Body shown)
NEMA 4X Enclosure (ABS Plastic). 150# or 300#
flanged mounting is optionally available. JUNCTION BOX (XP1) (Mounting Bracket is included)
CORD GRIP Explosion Proof
COMPRESSION Available probe lengths (C) are 6", 12", 15", (Cast Aluminum)
FITTING (No Electronics
3.00 dia 18", 24", 30", 36" or 48". 8.00 Required)
25' CABLE SUPPLIED
Can be shortened or even
lengthened in the field
by up to 1000' without SVA SERIES ISOLATION VALVE ASSEMBLY
affecting calibration SAFETY CHAIN5 MOUNTING HARDWARE FOR
INSERTION METERS 13
4.50 COMPRESSION FITTING
SIL SERIES INTEGRAL EXPLOSION PROOF12 10.004 The Isolation Valve Assembly permits insertion
(BLIND) MASS FLOW METER or removal of probe without shutting down
4.69
In-Line Style1, 8 ISOLATION VALVE
B the gas line.
(Also available as Insertion Style) 3/4" WELD-LET
2.55
Explosion Proof Enclosure (Cast Aluminum), Class I,
Division I, Group C, D. 150# or 300# flanged ends
8.00
are optionally available. (1" Flow Body shown) STCF SERIES TEFLON FERRULE COMPRESSION
FITTING MOUNTING HARDWARE
1/2" tube x 1/2" pipe fitting (shown, not to
1 NPT Fittings standard (150# or 300# flanges optional) 11 When flanges specified, face-to-face dimensions same as 1.92
1.92 scale), is used for low pressure insertion appli-
2 Flanged Mounting available for high pressure operation Length on Table on page 4. cations to 125 psig (Stainless Steel Ferrule
4 10" nominal when collar clamps are together 12 All Explosion Proof Meters are Class I, Group B, C, D, Class II
5 Safety chain is sized depending on probe length to Group E, F, G and Class IV and have Cenelec, EExd Enclosure optional for higher pressure applications –
prevent probe from escaping above compression fitting. IIC, IP66 ratings and are NEMA 4X, 7BCD and 9EFG rated. up to 225 psig). Also available in 3/4" tube x
6 At 650 psig,force exerted on 1⁄2 diameter probe is approx. (All Junction Boxes, when applicable, are Class I, Group C
125 psig. & D; Class II, Group E, F, G, and NEMA 7 and NEMA 9 rated.) 3/4" pipe size.
7 3/4" Female NPT access holes for wiring (conduit 13 Used for pressures to 650 psig (shown for use with 1⁄2" x
3
compatible) ⁄4" NPT and 3⁄4" x 1" NPT.
8 Access holes are 1⁄2" NPT (supplied capped) 14 Other materials available
9 All NEMA 4X Enclosures have 4" depth 15 NOTE: Only one Conduit Hub is supplied, and one Cord
10 Circuit board available separately, 3" diameter. Grip is supplied with SRG Series.

SAGE METERING, INC. {5}


APPLICATIONS
COMMON APPLICATIONS FOR SAGE THERMAL MASS FLOW METERS

Compressed Air Monitoring Perform Audits


Detect Leaks
Improve overall cost effectiveness of compressed air system
Eliminate waste – Improve efficiency of overall system
Sub-Meter for Conservation Reduce energy expense
Monitor Plant Nat. Gas Consumption Plant Monitoring Track billing meter, assess daily flow peaks, determine demand for each shift
Sub-Metering Monitor department usage, and analyze associated expenses
Natural Gas Distribution Check Meters Natural gas distribution lines require “check” meters to measure usage (downstream of gate valves)
Source Control Monitor NG exhaust (Dual Channel Meters—Low Flow and High Flow)
Specialty Gas Monitoring Nitrogen and Argon Plant Metering Monitor flow rate and consumption of N2, AR and other specialty gases in a plant’s gas distribution system
Nitrogen and Argon Sub-Metering Sub-Meter N2, AR, etc. by department to determine cost savings
Nitrogen, Argon & Hydrogen Consumption Totalize mass flow for customer billing
Flare Gas Exhaust Flow Monitor normal and upset condition (Dual Channel Meters)
Monitor individual flare header pipes
Wastewater Treatment Aeration Flow Monitor and adjust the air flow bubbling into aeration tanks to control the critical dissolved oxygen level
Digester Gas Monitor the flow of CH4/CO2 mix in the digesters to facilitate the sewage treatment
Biogas Measure the excess gas for storage as backup fuel, and monitor emissions
Odorizing Monitor Oxygen flow in odorizing (fragrancing)
Water Purification Oxygen Monitoring Monitor O2 flow rate in ozone generator systems that purify municipal water supplies
Incineration Exhaust Flow Measure exhaust flow in incinerators
Combustion Control Natural Gas, Oxygen, Air Flow Monitoring and controlling of combustion air or oxygen and natural gas ratios are critical for optimal boiler efficiency
Stoichiometric ratio control
Tablet and Pill Coating Monitor Atomizing Gas Monitor the atomizing air or nitrogen flow rate in the pharmaceutical pill coating process
Monitor Exhaust Gas Monitor the flow rate of the downstream side of the pill coating process to determine the by-product emission
Nitrogen Blanketing Tank Blanketing Measure the nitrogen flow layering over the contents of the tank to “insulate” the product
Surface Blanketing Move product, such as pills, along a layer of nitrogen on a conveyer. Fluidized beds
Fuel Cells Air Flow Monitor the air flow to control the efficiency of fuel cell power plants
Hydrogen Flow Monitor the hydrogen generated in the fuel cell process
Landfill Gas Methane CO2 Mix Monitor gas to engines for electrical power
Testing Hydrogen Cooled Turbines Hydrogen Leak Detection Measure air flow rate that is analyzed for hydrogen presence
Natural Gas Odorizing Scent Control Monitor NG flow to control ratio of liquid scent injection
Plastic Production Argon, Nitrogen Flow Monitor AR & N2 flow rate involved in certain plastics production
Fiberglass Production Combustion Control Monitor flow rate of natural gas and oxygen to control air-fuel ratio to optimize burners resulting in higher
quality product and greater product yields
Pump Manufacturing Test Pumps Monitor air flow to test pumps for manufacturing quality control
Natural Gas Furnace Natural Gas Consumption Measure NG consumption for furnaces that burn NG in a nitrogen environment
Steel Fabrication Argon and Nitrogen Flow Rate Monitor and control AR & N2 flow rate for bottom stirring and purification
Coke/Oven Gas Monitor the refined end of the coke oven gas process
Metals Recovery Air Flow Rate Air flow rate is critical in forming bubbles that capture precious metals that otherwise are not recoverable
Plastics Molding Nitrogen Flow Nitrogen flow rate controls the forming of plastic shapes such as gas tanks
Spray Drying Uniform Air Flow Monitor air flow to uniformly dry components in pharmaceutical, food processing, fertilizer and chemical industries
Aluminum Smelters Natural Gas and Air Flow Combustion control for boilers and furnaces
Chlorine and Argon Flow Hastelloy flow meter monitors the CL2 and AR in the smelting process
Remediation Air Flow Meter the air intake used to detect contaminated soil
Powder Painting Painting Cars with Robotics Monitor air flow, including turbine air, atomizing air and shaping air to control automotive paint quality
Heat Treating Air Flow Monitor air flow in heat treating furnaces to improve quality
Glass Manufacturing Combustion Control Monitor oxygen and natural gas flow to control burners for optimal glass production
Pulp and Paper Drying Air Flow Improve product quality by monitoring drying air flow
Food Process Hydrogen Flow Hydrogen flow rate involved in producing vegetable oil
Nitrogen Flow Nitrogen flow measurement for food preservation
Coal Fired Power Plant Primary and Secondary Air Flow Monitoring the primary & secondary (reheat) air flow in coal fired utilities for boiler efficiency
Exhaust Flow Monitor stack exhaust for environmental compliance
Nitrogen Purge Nitrogen Flow Rate Numerous processes require a purging of the process to clear out residual gases and contamination.
Leak Detection Low Air Flow Rate Measuring small amounts of air flow detects product flaws in many industries, including filter manufacturing
{6} SAGE METERING, INC.
VERSATILITY
SAGE GAS MASS FLOW METERS – CONFIGURED FOR ANY APPLICATION

Your Pipe Size

1/4”
Sage In-Line Meters
S( _ _ )-025
Sage Insertion Meters

N/A
Building a Model Number
1. Select Style
■ Integral (I) or Remote (R)
■ General Purpose (G), Explosion Proof (E) or Sage Lite (L)
3/8” S( _ _ )-030 N/A ■ In-Line (-XXX) or Insertion (-XX-XX)

2. If In-Line, select pipe size (see table on page 4 for Flow Body Length)
1/2” S( _ _ )-050 N/A
3. If Insertion, select probe diameter, and length
3/4” S( _ _ )-075 N/A ■ [(-05 = 1/2" tube (standard); -07 = 3/4" tube (optional)]

S( _ _ )-100 4. Select probe length based on mounting hardware choice (the chart assumes
1” S( _ _ )-05-12 utilizing Sage Isolation Valve Assembly mounting hardware)
S( _ _ )-125 ■ -12 = 12" length; -15 = 15" length
1-1/4" S( _ _ )-05-12
■ -18 = 18" length; -24 = 24" length; -30 = 30" length
1-1/2” S( _ _ )-150 S( _ _ )-05-12 ■ -06 = 6" length (assumes utilizing Sage Teflon Compression Fitting
mounting hardware)
2” S( _ _ )-200 S( _ _ )-05-15
5. If Insertion, select mounting hardware (Valve or Compression Fitting)
2-1/2" S( _ _ )-250 S( _ _ )-05-15 ■ SVA05 = Sage Isolation Valve Assembly for 1/2" probe
■ SVA07 = Sage Isolation Valve Assembly for optional 3/4" probe
3” S( _ _ )-300 S( _ _ )-05-15 ■ STCF05 = Sage Teflon Compression Fitting for 1/2" probe
■ SSCF05 = Sage Stainless Steel Compression Fitting for 1/2" probe
4” S( _ _ )-400 S( _ _ )-05-15 ■ STCF07 = Sage Teflon Compression Fitting for optional 3/4" probe

6”-14” N/A S( _ _ )-05-18 6. Select operating voltage: -DC24 = 24VDC; -AC115 = 115VAC;
-AC230 = 230VAC
16”-24” N/A S( _ _ )-05-24 7. Add symbol of gas being measured at end of part number
26”-36” N/A S( _ _ )-05-30 8. Add Options (such as RG2: Dual Range; HTO1 = High Temperature Operation)
9. Include Full Scale Flow Rate and operating temperature and pressure
>36” N/A Consult Factory in description

Example of a Model Number


S I G - 0 5 - 1 5 - S VA 0 5 - A C 1 1 5 - N G This model number describes a Sage Integral Style General Purpose Insertion
Mass Flow Meter for Natural Gas with a Sage Isolation Valve Assembly,
Base Model Probe Probe Mounting Power Gas 1/2" x 15" long probe, and 115VAC power
(i.e., I=Integral, Diameter Length Hardware
G=General Purpose)

This diagram depicts INTEGRAL GENERAL PURPOSE REMOTE GENERAL PURPOSE 2


IN-LINE INSERTION IN-LINE INSERTION
the various styles

and base models

currently offered by

Sage Metering, Inc.

including General
SIG-XXX SIG-XX-XX SRG-XXX SRG-XX-XX
Purpose, Explosion
INTEGRAL EXPLOSION PROOF REMOTE EXPLOSION PROOF
Proof and Remote
IN-LINE INSERTION IN-LINE INSERTION
Configurations.

1 “Lite”refers to “Sage Lite”Product Line


for OEM customers (consisting of blind
SIE-XXX SIE-XX-XX SRE-XXX SRE-XX-XX
enclosures) or optionally offered as a
single round circuit board only. Also 1
INTEGRAL LITE GENERAL PURPOSE 1
REMOTE LITE GENERAL PURPOSE OPTIONAL
available upon request with explosion EXPLOSION PROOF 3
proof enclosures. IN-LINE INSERTION IN-LINE INSERTION IN-LINE OR INSERTION
2 Remote General Purpose style has an
Explosion Proof Junction Box (with no
electronics) as well as the General
Purpose (NEMA 4X) Remote Fiberglass
Enclosure.
3 Available in any style, although
Integral Insertion is shown.

SIL-XXX SIL-XX-XX SRL-XXX SRL-XX-XX SIL or SRL

SAGE METERING, INC. {7}


Make the Wise Choice.
Choose Sage Flow Meters.

Sage Metering, Inc.


8 Harris Court, D1
Monterey, CA 93940
866-677-SAGE (7243)
Tel 831-242-2030
Fax 831-655-4965
www.sagemetering.com

Rev. 0806