Mobile Moisture Meter for Plastics

AQUATRAC - 3E
®
Moisture Meter for Plastics

The water content of High-Tech

AQUATRAC®-3E
plastic material has a great influ-
ence on the quality of the finished
product. The test should be made
swiftly on an instrument with a
simple test procedure.
With the AQUATRAC® - 3E different
AQUATRAC - 3E is the result of
® ranges are obtained by different
continuous development of the sample weights. AQUATRAC® - 3E
popular AQUATRAC® product, is able to detect even the most
which has been on the market minute traces of moisture (less
for over 20 years. Developed pri- than 0,01% H2O) in large, repre-
marily for the plastics-processing sentative testing samples (up to

Ranges
industry, the device measures 100 g). In the case of lower-weight
the moisture content of granular samples, the measuring range can
solids. be increased to detect very high
degrees of moisture.
AQUATRAC® - 3E is robust, com-
pact and easily transportable. Since AQUATRAC® - 3E is now
This means there are many differ- able to achieve ultra-precise read-
ent ways to use AQUATRAC® - 3E ings using a single measuring cup,
directly at the production site, for it is no longer necessary to switch
example: from one measuring cup to another.

- To check incoming granulates


- To monitor and optimise the
drying of granulates
- To measure granulates right The measuring volume consists
Measuring procedure

at the machine mainly of the sample container,


- To take measurements from a which contains the sample and the
finished component, e.g. after reagent.
conditioning Weighing the sample there is no
- To take laboratory need to meet the exact value.
measurements The actual weight is fed into the
- And many more! instrument. This simplifies the
handling. The sample is placed
As the principle of operation is into the sample container which
an absolute chemical method, no is then evacuated by the built - in
calibration is required for each dif- vacuum pump, which takes approx.
ferent substance tested. 30 sec. The pressure obtained is
AQUATRAC® - 3E can be used lower than 10mbar. The sample
independently of a computer or container is then heated up to the
other peripheral. selected temperature (between
60°C to 200°C).
Operating the AQUATRAC® - 3E
involves only a few simple steps,
which are executed via the device’s
touch screen. If the user prefers,
he can also have the touch screen
guide him step by step through the
measurement process.

AQUATRAC®-3E with open reaction vessel


Measuring principle Water and calcium hydride react
according the following equation,
producing hydrogen:
CaH2+2H2OCa(OH)2+2H2
This reaction takes place in
the sealed reaction vessel of
AQUATRAC® - 3E. It is evacuated The reagent calcium hydride used
by using a built - in vacuum pump, by AQUATRAC® - 3E is in a gra-
before the measurement. The nular form and is specific to water.
container is then heated up to It is non-polluting and non-toxic, so
the measuring temperature. The no special disposal is required. By
evaporating water reacts with the using the dosing spoon, the mesh
reagent calcium hydride to gen- based insert is filled with a certain

Reagent
erate a gas. The gas produced is amount of the reagent. The quantity
hydrogen; the gas pressure is of one filling is sufficient material for

AQUATRAC -3E
proportional to the water content a couple of measurements and the
in the sample and is monitored amount of hydrogen produced by
by means of a piezoelectric trans- each measurement is very low. The
ducer. AQUATRAC® - 3E calcu- calcium hydride can be supplied in
lates the ratio of pressure to sam- quantities of 250g, which is suffi-
ple weight and displays the result cient for approx. 1000 tests.
in terms of H2O content, either as
a percentage or in parts per million
(ppm). Volatiles other than water do

®
not react with the reagent and will
condense, hence not influencing
the reading. The reagent is placed
in a mesh based insert above the AQUATRAC® - 3E contains an ex-
sample. The partial pressure in the
Product data bank

tensive product data bank with the


gas system is zero; therefore the required default settings for bulk
total water content is accurately density and measuring tempera-
measured. This, in combination with ture. This allows measurements
the heat applied and the vacuum, to be taken quickly, without having
means results are obtained in a to input the necessary parameters
short time. Furthermore the test is each time.
not affected by the presence of ox-
The databank can be expanded
ygen and no carrier gas is needed.
or updated at any time, ensuring
a perfect fit for individual customer
needs!

All dimensions in mm
Thermoplastics, e.g.:
Acrylonitrile butadiene styrene ABS
Polybutyleneterephthalate PBT
Polyamide 6.6 PA 6.6 For calibration of AQUATRAC® - 3E

Applications
Polyamide 6 PA 6 GF 30 the standard sodium molybdate
Polyamide 12 PA 12 dihydrat according DIN EN ISO
Polycarbonate PC 15512 is used.
Polyester PET
Calibration is made like a standard

Calibration
Polyester elastomer TPE
test and can be done on site.
Polyetherimide PEI
Polyethylene HDPE
Polyethylene LDPE
Polyethyleneterephtalate PETP
Polymethylmethacrylate PMMA
Polypropylene PP
Duroplastics, e.g.:
Epoxide resin
Acrylate The AQUATRAC® - 3E’s internal
Silicon resin hard drive can store up to 500 read-
Vinyl resin ings. Measurement results can be
Elastomers, e.g.: easily transferred to a computer for

Data storage
Styrene-butadiene rubber SBR further processing via an USB stick.
Chloroprene rubber CR The AQUATRAC® - 3E is optional
Polyurethane rubber PUR via an Ethernet interface network-
compatible, too.
By connecting a printer, results
data can be directly printed from
AQUATRAC® - 3E.

Technical data
Measuring principle Chemical reaction with calcium hydride

Sample weight 0,1 g - 100 g according to range

Test temperature 80 °C - 200 °C in 1 °C - steps

• Measurement accuracy:
+ 2% of reading / + 1% of range
Accuracy
• Reproductibility:
approx. + 1% of reading

3 different ranges:
• lower 0,1%
Ranges
• 0,1% - 0,5%
Brabender • higher 0,5%

Messtechnik® Test time 10 - 45 min. dependent on material


GmbH & Co. KG
Display % H2O or ppm
Kulturstraße 51-55
Power supply 100 - 230V (50/60 Hz, 450W) / dependent on version
D- 47055 Duisburg
Dimensions (W x D x H) 51 * 32,5 * 23 cm
Tel.: +49 203 99819-0
Fax: +49 203 99819-22 Weight 13,0 kg / 14,8 kg

www.brabender-mt.de
sales@brabender-mt.de
AQUATRAC-3E / GB / 06 / 2013