Occurrence
Detection
Severity
Potential
Op. Potential Failure
Process Function Potential Effect(s) of Failure Cause(s) of Current Controls RPN
No. Mode
Failure
Incomplete
On product: product can be reject
information to Varification of Mill TC
Raw Material Wrong grade of material On next process:none
10 5 supplier about 2 with p.o. provided to 3 30
receiving reeived At customer's end:part can be
raw material supplier
reject
grade
Incoming
inspection not
Wrong material composition On product: product can be reject
done / unskilled
& Grade recived according to On next process:none sample to be send
DAIMLER Raw material 5 inspector lack of 2 3 30
At customer's end:part can be to third party spectro
standard- E-500 knowldege to
reject
comapre mill tc
with std
50 Inprocess Inspection
On product:part rejects
part not qualified in receiving On next process:part reject first part approvel not 100% inspection to be
60 final inspection
gauge 5 2 2 20
At customer's end:part reject & done in bending done
customer dissatisfied
On product:part rejects
On next process:part reject inspection not done 100% qualify with reciving
70 Pre dispatch inspection wrong dimension observed 5 at final stage 3 gauge 2 30
At customer's end:part reject &
customer dissatisfied
Revised
Responsibility
Recommended
& Completion Action(s) Taken
Occ.
Sev.
Det.
RPN
Action(s)
Date
OVED BY : RAM PRASAD