Kent

You might also like

Download as pdf
Download as pdf
You are on page 1of 14
NSN Mineral RO™ HOUSE of PURITY KENT ACE* Mineral RO™ Water Purifier Instructions Handbook KENT RO TECHNOLOGY ‘Maintains minerals while reducing dissolved lmpuritis with double purification Kent RO Deta Hai Sabse Shudh Paani Mineral RO™ he Process Kent RO Systems Limited. tented vide Patent No.: 199716 Welcome to KENT Dear Customer Welcome to the worid of KENT, leaders of water purification industry in India. With a KENT product you have all the reasons to smile, since at KENT we take pride in the quality and laboratory-tested performance of our products. We are confident that your decision to own KENT ACE* Mineral RO™ will go a long way in serving you with pure and mineral enriched drinking water — thus keeping you and your family in good health. We assure you, that you will be satisfied with its trouble-free performance and quality which comes without any compromise. This manual is an effort towards familiarizing you with the operation and maintenance of KENT ACE* Mineral RO™, Before operating the unit, please read it thoroughly and retain it for future reference, To ensure that the warranty of your water purifier is effective, fill up the enclosed warranty card and send the installation report within 15 days of purchase. Should you need further assistance, do not hesitate to contact your nearest KENT dealer or branch. Best Wishes KENT RO SYSTEMS LTD. Table of Contents =s3 00 NOOO © = Kent Technology Salient Features of Kent ACET Items in the Box Important Instructions Reverse Osmosis Process UF Process Water Flow Diagram Electrical Circuit Diagram Automatic Operation Installation Instructions TDS Adjustment Starting-up the Purifier Recommended Usage of Rejected Water Maintenance Technical Specifications NSN Mineral RO” HOUSE of PURITY O©MNVNNAGDA AHN KENT TECHNOLOGY - A Breakthrough in Water Purification* Presenting the KENT ACE" Mineral RO™ Water Purifier; it uses futuristic and state-of-the-art technology to provide purer & healthier drinking water. The heart of KENT ACE” Mineral RO™ Water Purifier is a Reverse Osmosis membrane having capilaries as small as 0.0001 microns that reduces even dissolved impurities (salts and heavy metals) and even converts hard water to sweet and purer drinking water. KENT ACE” Mineral RO™ Water Purifier also allows the user to contol the Total Dissolved Solids (TDS) level of purfied water. Reduces Dissolved Impurities ity Water ‘Raw Water cal Retains zzanta ee Purer Water Reduce Bacteria & Viruses Salient Features of KENT ACE* Mineral RO™ Water Purifier * Double treatment by RO + UF processes © RO Membrane fused inside membrane housing * Inbuit TDS Controller that alows adjustment of to prevent tampering TDS level of purified water © Vertically mounted SMPS for protection from * Suilable for Purtication of Brackish /Tap Water/ water Municipal Water Supply © Use of push fitings for leakage and * Wall mounted design; best suited for Indian maintenanos free performance homes and offices © Anew eye appealing design * 7 rs, storage tank ABS construction for corrosion free use * Fully automatic operation, with auto-on and auto-off function Items in the Box 1. KENT ACE® Mineral RO™ 01 No, 2. 3-Way Connector 01 No. 3. SS. Ball Valve 01 No, 4, Food Grade Pipe - Blue 1/4 inch 2.5 meter 5. Food Grade Pipe - White 3/8 inch 2.5 meter 6. Instruction Manual 01 No. 7. Sorews & Plastic Inserts 02 Nos, each 8. Sticker Center Drill 01 Nos. “Tested & Certified by TUV-SUD South Asia (P) Ltd. aN Mineral RO” pcre HOUSE of PURITY Important Instructions ‘Avoid exposure to direct sunlight and installtion in damp areas, Make sure that the temperature of water entering the purifiers within 10-35 of Moke eure thatthe rejected water BI) 'S not placed at a lel higher than the system, cthewise rected water ray flow backwards into the parr, Meximum distance between the water source and the pusier should not be mere than 3 meters, aaEe ‘Avoid sharp bends in the pipe fitings. Do not bend er block. the reject water pipe ‘case of not using the punter for move than ‘wo days, kndly satch ofthe power supely and crainthe storage tank, KENT Use Genine Kent spares for ‘optmum performance: Donot contine the purer in a cabinet To keep the storage tank ean, it should be drained once In 16 days, fe Do not tr to serve the puri on your own. Instead call sevica technician fer help. Reverse Osmosis Process The Reverse Osmosis process, also known as hyper fitration, is the finest fitration process known til date The process ensures reduction of particles as small as ions from a solution. Reverse Osmosis uses a ure j- permeable membrane to reduce salts from potable / brackish water. in Reverse Osmosis, water; applied to the concentrated side forces the pracess of osmosis into reverse. Under enough pressure, treated ‘water is "squeezed through the membrane from the concentrated side to the diluted side. Salts dissolved in water as charged ions are repelled by the RO membrane. The rejected impurities on the concentrated side of the membrane are washed away in a stream of waste water and thus, donot get accumulated as in a traditional fiter, Feed Water Storage Tank Under Pressure : REJECTED TREATED : Z. [CONTAMINANTS WATER (DILUTE) Water Flow Semipermeable Waste Stream Membrane to Drain UF Process Ultra Fitration is a separation process that uses membranes with pore sizes of 0.01 micron. UF membranes reduce high molecular-weight substances, colloidal materials, and organic and inorganic polymeric molecules including bacteria and viruses. Low applied pressures are therefore sufficient to achieve high flux rates from an Ultra Filtration membrane. Water Flow Diagram KENT we Mineral RO™ ater 7 Dees 4 HOUSE of PURITY cM 20020) coos [10 7 ue 9 i @ C= =] —— any { TIP eons) 5 TIEN DESCRIPTION Reject [sons [Low nessun soot Was i DE = [se | seo sy 5 [ina | socenoro va + aot — eer CEN us a re anc =| sono or mene (20005) 20148] WATER STORNGE TAN sis —[ RoR RS ST dl 3 em LIT eee nor — Electrical Circuit Diagram [ED] ves Jezooss CaN ateno Sine | 0029 ica] —— + 2606 } [Cas — a reson x3] CEP INOTE: The above specifications are subject to modifications for improvement without notice] 4 Installation Report Product : KENT ACE* MINERAL RO™ WATER PURIFIER Serial No.: Customer's Name: Customer's Address + Invoice No.: Invoice Date: Installation Date: Service Provider's Name: Service Provider's Address Customer's Ph.: TDS of Purified Water: Customer's Signature : Service Provider's Ph.: TDS of Raw Water: Service Provider's Stamp: By signing on this installation report, the customer hereby agrees to the terms & conditions of warranty mentioned on the back side of the warranty card. Automatic Operation ©The purifier automatically shuts off when the ‘The purifier automatically restarts when water storage tank is full level drops below the maximum, * The purifier does not start when inlet water * The purifier does not allow any water relection in supply pressure falls below 0.3 kg/om. absence of electricity /when tank is full Installation Instructions ‘The KENT ACE* Mineral RO™ Water Purifier is a convenient and easy-to-install wall mounting model, Recommended Site Preparations : © Single Phase 100 - 250 V AC, 50-60 Hz not more than 3m away from the point of installation. © Raw water supply with ¥ inch nipple not more than 3m away. © Drain for reject water not more than 3m away. Installation space as per the dimensions of the purifier © Wall/plane surface for mounting screws and holding the machine, Avoid installation on wooden and metalic stands. «For optimum inlet pressure, source water tank should be at least 10 ft. above the Purifier installed, ‘Install the purifier near a sink for easy availabilty of inlet and reject water lines. + The system and installation must comply with state and local laws and regulations Installation Procedure : 1. Sorew in two 10x50 seif taping screws, 5.4 inches (138 mm) apart horizontally. 2. Wall-mount the purifier with the help of slot holes given on back side. NSN Mineral RO™ Deieaees HOUSE of PURITY e Fasten the SS ball valve to % inch port of S-way connector. 4. Attach threaded end of 3-way connector to raw water supply and plug-off the ‘other end or connect to a tap. Now connect one end of white pipe to SS ball valve and other end to lower eloow fiting connector labeled as WATER IN, on the left side of purifier 6. Connect one end of biue pipe to upper elbow fiting connector labeled as | REJECT WATER and lead the other end to drain. 7. Tum en the lever given on SS ball valve to initiate the water flow to purifier. 8. Allow the fiters to pre-soak in water for 2-3 minutes. 9. Connect the power supply. 10. installation is complete TDS Adjustment* ‘The unique TDS Control System enables customers to retain the contents of natural minerals (TDS) in Purified water, as per their requirement. © Tuming the screw of the valve anti-clockwise, © —Tuming the screw of the valve clockwise, results in an increased mineral content. results in a decreased mineral content, Starting Up the Purifier ‘© Switch on the power supply dust particles present in different pipes and Allow the storage tank to filo its maximum Bete capacty"* * Plug back the drain plug ‘© Switch off the power supply * Switch on the power supply '* Open the drain plug present at the bottom of —* Purifier is now ready to use the storage tank and drain the tank ‘completely. This would remove the residual Recommended Uses of Rejected Water ‘Athough the rejacted waterhas high concentra- can be used for gardening purpose. The high tion of salts, it is absolutely clean and free from concentration of salts and minerals accelerates impurities such as chlorine, dirt, sand, etc, This the plant growth, Rejected water can also be rejected water usually goes down the drain but Used for cleaning utensis, mopping etc. “Tested & Certified by TUV-SUD South Asia (P} Ltd. ™ Tested or certified flushing time - 24hrs. KENT Mineral RO” ria HOUSE of PURITY Maintenance To ensure that the purifier operates at its optimum level, a routine maintenance must be performed. The frequency of the maintenance will greatly depend upon the raw water quality and consumption of treated water. * Storage tank must be drained once in 2 weeks. * Replace sediment filter and activated carbon To do 50, switch off the power supply, open the fiter once in a year or eater if they get clogged, drain plug at the bottom of the tank & allow the Itis recommended to change the FRT along with water to drain. Then sorew back the plug and the fters. switch on the power supply. Replace UF membrane onos in a year or earlier i © Replace the RO memibrane once in a year. it gets clogged. * Ifyou are not going to use the purifier for a long time | in case you are on a holiday, tour or out of home}, make sure that you disconnect the power supply, turn off the raw water supply and drain the storage tank. The reverse osmosis system contains a replaceable treatment component crtical for the effective reduction of total dissolved solids and that product water shall be tested periodically to verfy that the system is Performing properly. Replacement of spare parts are as under -20010 SP Inline Sediment Fiter 8 -20009 SP_ Inline Carbon Block Filter 8" -20002 SP RO Membrane Welded 8" Housing -20018 SP FRT 550 -20004 ‘SP UF Membrane 8" housing Note: Fiters and membrane are consumables, Their replacement time depends upon the quality of raw water and water consumption. They ere not covered under the waranty. However, ia fiter chokes within six months and a membrane within a yeer, wil be cleaned/repaired/replaced free of cost. Changing the fiters and system inspection Is available on call, The treatment capacity of RO membrane will reduce wih time due to cogging of pores of membranes. “Tris reverso osmosis system contains a replaceable component critical to the efficiency of the system. Replacement Of the reverse osmosis component should be with one of identical specifications as defined by the manufacturer, to ensure the same efficiency and contaminant reduction performance.” ‘Technical Specifications ‘Modi! No. 11036 Purification Production Rate Upto 15 nr or 0.26 Limint ‘Mounting Wall Mounted Inlet Water Pressure/Temp (Min) 0.3kg / om? or 4.267psi / 10°C Fier Cartridge ‘Sediment, Activated Carbon, UF Fitter UF Membrane 0.1-0.01 Micron Storage Capacity 7 Booster Pump Voltage 24V DC Input Power Supply ‘Single Phase 100-250 V, AC, 50 - 60 Hz * Puriication capacity tested for raw water having TDS level of 750 ppm at room temperature. KENT Mineral RO™ HOUSE of PURITY GOLD MEMBER For customer complaints, contact customer care officer at: A-2, Sector-59, Noida, UP-201 309, India Call:09582-123456 or Fixed line: +91-120-4669666 E-mail; service@kent.co .in or Visit us at www.kent.co.in Manufactured by: KENT RO SYSTEMS LTD. Khasra No.9, Vilage-Bantakhedi, Tehsi-Roorkee, District Haridwar, Uttarakhand-247668, India Marketed by: KENT RO SYSTEMS LTD. A-2, Sector-59, Noida, U.P-201309, India Iwoatgntr Ph,: +91-120-3075075 E-mail: sales@kent.co.in Website: www.kent.co.in February, 2015

You might also like