Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

9/18/2019 Untitled Document

> Fermer la page

Equipment included in a CO2 plant

AXIMA REFRIGERATION offers the following equipment :

For CO2 production.


- Absorber : Absorption of CO2 contained in flue gas, e.g. in an amine solution.
- Stripper : Extraction of CO2 from amine solution.

For any CO2 purification installation


with an output between a few tens kg/h to several tens of t/h, AXIMA REFRIGERATION can supply the following equipment : catalytic
oxydation tower, Foam trap, scrubber tower, gasometer, CO2 compressor, dryer, purifier, liquefaction unit, distillation tower, liquid CO2
storage, vaporiser, bottle or lorry filling station.
Diagram of brewery CO2 purification installation :

www.aximaref.com/dyn/imprimer.php?link=/english/co2/recuperateur/equipements/index_equipements.php 1/3
9/18/2019 Untitled Document

- Catalytic* oxydation tower : catalytic oxydation for removal of hydrocarbons


components.
- Foam trap : Traps the foam issuing from fermentation vats, etc.
- Scrubber tower : CO2 is cleaned with water in order to remove yeast residues and
impurities
- Gasometer : Adjustment of average CO2 flowrate to be treated.
- Separator : Separation of water contained in gas.
-
CO2 compressor : The gaseous CO2 at atmospheric pressure is compressed, and
condensed. AXIMA REFRIGERATION offers oil-free reciprocating compressors (self-
manufactured for high flowrate) and oil lubricated screw compressors for over 2 t/h, with
total oil separation system.
- Dryer : Elimination of water vapour fromthe gaseous CO2 in order to avoid corrosion or
hydrous ice formation. It consists of 2 distinct vertical columns, one in operation, the other
in regeneration.
- Purifier : Removal of odorous compounds (ester, aldehyde and hydrogen sulphide, etc)
and oil in case of using screw compressors, with activated carbon filter.
- Liquefaction unit : Gaseous CO2 condensation passing through the refrigerating unit
evaporator.
- Distillation tower* : With distiller and condenser, to get extremely pure CO2.
- Liquid CO2 storage : Under pressure at low temperature in a thermally insulated
cylindrical tank, often refrigerated, with a capacity between 1.5 tons and 100 tons. A

www.aximaref.com/dyn/imprimer.php?link=/english/co2/recuperateur/equipements/index_equipements.php 2/3
9/18/2019 Untitled Document
system allowing to keep the required pressure in the tank with emergency power may be
installed, in case the main installation should stop.
- Vaporiser : The vaporisers vary according to the source of heat required for vaporising :

· Steam : CO2 output 500 kg/h, 1t/h and 2t/h.


· Electrical : CO2 output from 50 to 500 kg/h per unit.
· Ambient air : CO2 output up to 1500 kg/h.
- Bottle or truck filling station, including :

· Filling pump.
· Electronic weighing machine (for bottles).
· Valves station

*: special application

AXIMA REFRIGERATION FRANCE


6 rue de l'Atome B.P. 9 67801 BISCHHEIM / Tél : +33 3.88.19.19.00 / Fax : +33 3.88.19.19.49

www.aximaref.com/dyn/imprimer.php?link=/english/co2/recuperateur/equipements/index_equipements.php 3/3

You might also like