Agenda
›Assessment / Findings
›Challenges
›Conclusions
RDK 4 Power plant
RDK 4 Projekt Data
Rheinhafen Dampfk
ampfkraftwerk:
› Karlsruhe, Germany
› Small o&m contract - end with the C-inspection performed
› Plant scope covered by EnBW
RDK 4,
Karlsruhe
Zürich
CH
RDK 4 – 2nd C-inspection
This C-inspection:
inspection:
Scope:
Scope:
› Gasturbine C-Inspektion
›Assessment / Findings
›Challenges
›Conclusions
Gas Turbine scope – scheduled exchange of HGPP
SEV Combustor:
- SEV Inner Liner segments
- SEV Outer Liner segments Structural parts & Rotor:
- SEV Burners
- SEV Diffusors (OGV) - MBH40 Internal Cooling Air Pipes
- SEV Lances (one chip design)
Agenda
›Assessment / Findings
›Challenges
›Conclusions
Low Pressure Compressor - blades
Small dent at
airfoil
Cleaning done thoroughly
Small dents were blended and polished
Low Pressure Compressor - vanes
Wear
Front segments
Sieve
EV Combustor
LPT Blade 1
Low Pressure Turbine
LPT Blade 2
LPT Vane 2
Low Pressure Turbine
LPT Blade 3
LPT Vane 3
LPT Blade 4
Blade and vane row 4 found in good condition and therefore re-used
LPT Vane 4
Low Pressure Turbine
RHS A
RHS B
RHS B assessed – good for re-use
Minor rubbing from honeycombs seen
RHS C
RHS A assessed – good for re-use
Gas Turbine Rotor
A few
deformed
seals seen
Rotor re-conditioned
Agenda
›Assessment / Findings
›Challenges
›Conclusions
Scope split between site and factory Mannheim
Combustors
Cold side
bearing tunnel
as found repaired
Hot spot repair at exhaust duct
“MBH-
MBH-tunnel”
tunnel” special cooler not any more required !
☺
bearing tunnel
fan
Hot spot repair at exhaust duct
Diffusor outer
insulation
as found repaired
Once Through Cooler (OTC)
›Assessment / Findings
›Challenges
›Conclusions
Conclusions
912 MW
KWG TR
Frank-Peter Kirschning
June 15th, 2011 Energie
braucht Impulse
Site-
Site-View
Boiler-
Boiler-House
Electrical Precipitator
400 kV-
kV-Portal FGD-
FGD-Plant
Discharge Cooling Tower
Mechanical Draft Circular cooling/
cooling/ 28 Fans
Discharge Cooling Tower
Thank You
for your attention !