Floor Plan Legend General Notes Abbreviations List Standard Mounting Heights

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

For information on employee work area accessibility, please see policy paper "Employee Work Area

STANDARD MOUNTING HEIGHTS - Accessibility" located here: http://www.med.umich.edu/facilities/plan/dg/doc/policy/memo_16Sep01.pdf ABBREVIATIONS LIST FLOOR PLAN LEGEND GENERAL NOTES
ACT ACOUSTICAL CEILING TILE
EXISTING WALLS TO BE REMOVED 1. DO NOT SCALE DRAWING REPRODUCTIONS.

SOAP DISPENSER/ HAND


AFF ABOVE FINISH FLOOR

EXAM ROOM FLAG


2. THIS DRAWING REPRESENTS TYPICALLY ENCOUNTERED
BFS BUREAU OF FIRE SAFETY EXISTING WALLS TO REMAIN
ITEMS. NOT ALL ITEMS SHOWN MAY OCCUR WITHIN THE

PHONE RECEPTACLES
PAPER TOWEL
DISPENSERS CE CAPITAL EQUIPMENT SCOPE OF THIS PROJECT. REFER TO COMPLETE

LIGHT SWITCHES

FIRE ALARM PULL


NEW WALLS

HVAC CONTROL
SANITIZER
SPECIFICATIONS AND DRAWING DOCUMENTATION SET.

POWER/DATA/
CFI CONTRACTOR FURNISHED/ INSTALLED

INTERCOM
EXISTING WINDOW SYSTEM
CG CORNER GUARD
PTD MOUNTING
HEIGHT IS TO
15" MIN 20"
CH CEILING HEIGHT NEW WINDOW SYSTEM REFLECTED CEILING PLAN LEGEND
SD SPOUT OUTLET
cL HEIGHT cL CJ CONTROL JOINT CORNER GUARD 2'x2' FLUORESCENT LIGHT FIXTURE

72"

17" MAX
CL CENTER LINE CG

15" MIN
44" TYPICAL
44" MAX

44" MAX
9" MIN
36" MAX

34" MAX
END CAP

27" MIN
CJ CONTROL JOINT EC 2'x2' FLUORESCENT INDIRECT LIGHT FIXTURE
CLG CEILING FEC
9" MIN 6" MAX
FIRE EXTINGUISHER CABINET - SEMI-RECESSED
OR MATCH EXISTING DEVICE CPT CARPET 2'x4' FLUORESCENT LIGHT FIXTURE
HEIGHTS WHERE APPROPRIATE

MOUNTING HEIGHT FOR MOUNTING BARRIER FREE SINKS & URINAL CR CARD READER CUBICLE CURTAIN TRACK 2101 Commonwealth, Suite B
DISPENSERS IS TO TOP HEIGHT IS TO EWC & DRINKING LAVATORIES ACCESSIBLE CT CERAMIC TILE RECESSED DOWN LIGHT FIXTURE Ann Arbor, Michigan 48105-5759
EXISTING DOOR TO BE REMOVED www.med.umich.edu/facilities/plan/
OF DISPENSER OR TOP OF HIGHEST FOUNTAIN
EA EACH
HIGHEST OPERABLE OPERABLE PART TREATMENT ROOM LIGHT FIXTURE File Name/Archive No.
PART E/EXIST EXISTING EXISTING DOOR TO REMAIN 6/27/17 mcintyre, thomas
EXT EXTERIOR t:\fpd_shared\planning-standards\cad\prototypes
EXIT LIGHT (CEILING MOUNTED)
EJ EXPANSION JOINT NEW DOOR W/ DOOR NUMBER
SIX-VALVE BOX DR #

MIN 1-1/2" BETWEEN


ASSEMBLY SHOWN,
TYPICAL CENTER LINE ELEV ELEVATOR, ELEVATION EXISTING SUSPENDED ACOUSTICAL CEILING TO BE
TOP OF TP HOLDER FOR ALL SIZES. EXISTING DOUBLE DOOR TO BE REMOVED REMOVED
41"
AND BOT. OF GRAB
6"
EQ EQUAL TERMS & CONDITIONS FOR DOCUMENT USE
BAR
6"
FA FIRE ALARM EXISTING SUSPENDED ACOUSTICAL CEILING PROPERTY OF THE UNIVERSITY OF MICHIGAN
cL EXISTING DOUBLE DOOR TO REMAIN
TPD FD FLOOR DRAIN SUBJECT TO RESTRICTIONS
18"

TYPICAL
36"
12" 42" cL HANDRAIL NEW SUSPENDED ACOUSTICAL CEILING @ 8'-0" AFF
74"

12"
FND FEMININE NAPKIN DISPENSER NEW DOUBLE DOOR W/ DOOR NUMBER U.N.O. These plans are the confidential property of the University of Michigan.
48" MAX

58"
FND SHELF,
DR # These plans have been provided to you for the limited purpose of
GA GAUGE
45"

44"
40"

WHERE bidding and/or providing construction work at the University of


GYPSUM BOARD CEILING @ 7'-6" AFF U.N.O.
33"

SPECIFIED
Michigan. You acknowledge that these plans are the confidential
GL GLASS TEMPORARY 1-HR PARTITION AND DOOR

18"
18"

FND NOT
BELOW TPD property of the University of Michigan. You will keep the plans
18" GYP BD GYPSUM BOARD confidential and will not discuss with or provide these plans to any
SMOKE DETECTOR

~
third party, other than those employees, subcontractors, or
TOILET, GRAB BAR MIRRORS - SHOWER SHOWER MED GAS ZONE HDWR HARDWARE LAVATORY SINK consultants who are essential to completing your bid and/or work.
& TOILET PAPER COORDINATE NICHE SEAT/ TOWEL VALVE BOX Unless your company is selected to perform a part of the work, you will
HOLDER, FND TO BE WITH BAR HFES HEALTH FACILITIES ENGINEERING SECTION CLINICAL SINK S SPEAKER destroy all copies of the plans within 90 days of the bid due date.
INSTALLED IN BACKSPLASH, HR HOUR, HAND RAIL
FAUCET, SQUARE SINK
MULTI-STALL HM HOLLOW METAL FIRE SPRINKLER HEAD - NEW SPRINKLER HEADS
LOCATIONS. WRISTBLADES ROUND SINK ARE SHOWN FOR COORDINATION PURPOSES ONLY.
HT HEIGHT
FINAL SPRINKLER HEAD LOCATIONS SHALL BE
ID INTERIOR DESIGN MOP/CORNER SINK DETERMINED BY A CERTIFIED FIRE PROTECTION
JC JANITORS CLOSET FIRM, AND COORDINATED WITH ARCHITECT.
JT JOINT FLOOR TOILET FA FIRE ALARM - SEE ELECTRICAL DWG.
4" MAX
KP KICK PLATE
WALL HUNG TOILET
LAV LAVATORY M MICROPHONE - SEE ELECTRICAL DWG.
URINAL
ACCESSIBLE
THAN 40 LBS

LF LINEAL FEET
48" MAX AT
FOR MORE

78"

44" @ ADA
TO 40 LBS

72"
42" MAX

60" MAX
FOR UP
TO CABINET

WA WIRELESS ANTENNA - SEE ELECTRICAL DWG.


60"
48" MAX

HANDLE

58"

LT LIGHT TANK STYLE TOILET


WHEN
OPEN
34"

MAX MAXIMUM
GRAB BAR SUPPLY GRILLE - SEE MECHANICAL DWG.
MFR MANUFACTURER
FLOOR DRAIN
SEMI-RECESSED WALL MOUNTED FOLD DOWN SHOWER MOP & BROOM HOOK HAIR MIN MINIMUM FD
RETURN GRILLE - SEE MECHANICAL DWG.
FIRE FIRE BABY CHANGING CURTAIN ROD, HOLDER - NO DRYER MO MASONRY OPENING
EXTINGUISHER EXTINGUISHER TABLE HOOKS, AND SHELF
N NEW EXHAUST GRILLE - SEE MECHANICAL DWG.
CABINET CURTAIN FIRE RATING LEGEND
NTS NOT TO SCALE
CD's Issued To:
OF/CI OWNER FURNISHED/ CONTRACTOR INSTALLED SUITE EXTENTS BFS: HFES:
OH OVERHEAD NFPA 101, 2012: 18/19.2.5.7
REFERENCE SYMBOLS LEGEND
BFS Shop Drawing Submission Req'd:
OPP OPPOSITE HAND PLAN TITLE FA: SUPP:
SB SB SMOKE BARRIER 1 PLAN IDENTIFICATION W/ NORTH ARROW
PLAM PLASTIC LAMINATE (CREATES COMPARTMENTS)
0 1/2 1/1 2/1
Project Delivery Method:
DUPLEX RECEPTACLE
BEHIND WALL BOARD
24"

PT PAINT NFPA 101, 2012: 18/19.3.7.1 1 DETAIL TITLE


DETAIL IDENTIFICATION
A-1
0 1/2 1/1 2/1
UM Design Manager:
PTD PAPER TOWEL DISPENSER SP SP CORRIDOR WALL A. Martinez
Designed:
TO BOTTOM

TO CENTERLINE

PVC POLYVINYL CHLORIDE (SMOKE PARTITION)


OF TV

1
SECTION LOCATION IDENTIFICATION Drawn: A. Martinez
X"

STANDING

NFPA 101, 2012: 18/19.3.6 A-1


61 1/2"

49" - 56"

QTY QUANTITY
42" VARIES

60"

Coordination Checked:
SEATED

48"

42"
38"

RB RESILIENT BASE 1 1 ONE HOUR FIRE BARRIER Checked: A. Desmarais


24"

ELEVATION
X'-X" ELEVATION LOCATION IDENTIFICATION
RO ROUGH OPENING NFPA 101, 2012: 18/19.3.2 Approved: B. Harris
SF SQUARE FEET 2 2 TWO HOUR FIRE BARRIER Location:
TV WALL BOARD SHARPS GLOVE & GLOVE SPECIMEN BED PAN IV PUMP
BRACKET HOLDER BAR @MRI SIM SIMILAR NFPA 101, 2012: 18/19.1.3 1 DETAIL LOCATION IDENTIFICATION AT Keyword: Legend
(FOR OTOSCOPE/ CONTAINER APRON RACK DISPENSER PASS-THRU
18/19.2.2.3
A-1
ENLARGED SCALE
SPHYGOMOM- (NON-FERROUS) ST STL STAINLESS STEEL
ANOMETER/ 18/19.2.2.5 A
SSM SOLID SURFACE MATERIAL Project
THERMOMETER) D A-1 B ELEVATION LOCATION IDENTIFICATION
SPEC SPECIFICATIONS 3 3 THREE HOUR FIRE BARRIER C STANDARD
TPD TOILET PAPER DISPENSER
KEYNOTE IDENTIFICATION
TYP TYPICAL 1 1 1
DEMO / NEW / MISC
FLIP DOWN
UL UNDERWRITERS LABORATORY INC
WORKSTATION ADDITIONAL UNO UNLESS NOTED OTHERWISE 1
BULLETIN IDENTIFICATION WITH REVISION
BRACKET
SEGMENTS ADDED
CLOUD
36"X48" AS REQUIRED VCT VINYL COMPOSITION TILE Sheet Title
U.N.O.
VIF VERIFY IN FIELD ABC
ROOM NAME & NUMBER ARCHITECTURAL LEGENDS,
86"
ACCESSIBLE

123
VWC VINYL WALL COVERING
BRACKET)

STANDARD MOUNTING
48" AT

(SINGLE
60"

54"

WC WATER CLOSET
42"

42"
40"

X COLUMN GRID BUBBLE HEIGHTS, AND


WD WOOD
W/ WITH
ABBREVIATIONS
MARKER BOARD/ CHART COAT SURFACE WALL-MOUNTED MONITOR & 123 DOOR NUMBER TAG
W/O WITHOUT Project Number Sheet Number
TACK BOARD OR BRACKET MOUNTED WORKSTATION BRACKET
MAGAZINE & SHELF PROJECTION WP WALL PROTECTION
RACK SCREEN
X'-X"

X'-X"
CEILING HEIGHT TAG
EXISTING / NEW A-0