Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 2

1) PRECAST CONC.

POSTS
Size: 112mmx 112mm Ht =2.5m
Area of cross section of post = 0.112 x 0.112 =0.012544 m2
Chain link mesh: 50 x 50 mm
Diameter of wire 14 SWG = 2.032mm
DL
 Self-weight of post = 24 x 0.012544 x 2.5 kN
= 0.75264kN
 Self-weight of fencing =
1000𝑥1000
No. of openings in per sq meter of fencing =
52.032𝑥52.032

= 369.3677
No. of openings m a 2 x 3m panel = 369.3677(2x3) = 2216.206
Total length of wire in the panel =2216.206x2x0.052032
=230.6273m
Weight of 2x3 m wire mesh panel
1
=𝜋 (0.002032)2 X X 230.6273X 77 kN
4

=0.058 kN
 Self-weight of line wires (12 SWG) = 2 642 mm dia
π
= 6x3x (0.002642)2 x 77 kN/m3
4

= 0.0076kN
= say 0.008 (including barbs and fittings) Ref: BS CP3 -Chapter V

Total dead load =0.75264 + 0.058+0.008 kN Reynold'sHandbook

=0.81864 kN
WL

You might also like