Download as pdf or txt
Download as pdf or txt
You are on page 1of 5

DESIGN OF FOUNDATION F4 UNBRACED BAY

ALLOW.N.S.B.C = 150 kN/m2


ALLOW. N.S.B.C (SEISMIC CASE) = 187.5 kN/m2 Fck = 40 N/mm2
ALLOW. N.S.B.C (WIND CASE) = 187.5 kN/m2 Fy = 460 N/mm2
Unit Weight of Soil = 18 kN/m3 Clear Cover at Top = 75 mm
ALLOW. G.S.B.C = 204.0 kN/m2 Clear Cover at Bottom = 75 mm
ALLOW. G.S.B.C (SEISMIC CASE) = 241.5 kN/m2 Height of pedestal = 3.45 m
ALLOW. G.S.B.C (WIND CASE) = 241.5 kN/m2 Depth of foundation below FGL = 3.00 m
Increase in bearing capacity factor for Seis Load = 1.25 Lz = 5.00 m
Increase in bearing capacity factor for Wind load = 1.25 Lx = 3.50 m
t = 0.50 m (Thickness of Footing)
P1x = 0.80 m
P1z = 0.90 m
X Foundation CG P2x = 0.80 m
Load CG P2z = 0.90 m
3.50

1.75 FGL
Lx = 3.50 ex 0.80
0.80 P1 P2
ez Z 3.00 m
1.75 0.90 0.90

0.50 m
0.75 1.75 1.75 0.75

Lz = 5.00
Self Wt of Footing W1 = 218.75 kN
Wt of soil above Fdn W2 =(L X B-P1x X P1y - P2x X P2y)X(H-t)X18 = 722.70 kN
Wt of pedestal W3 =P1XXP1ZX(H-t)x25+P2XXP2ZX(H-t)x25 = 106.20 kN
Total Wt. = 1047.65 kN
RCC Design (Self Wt. of Footing+Wt. of Surrounding Soil)
Design for 1m width of slab 57.5 KN/m P1 P2
Design for maximum net soil pressure under the footing 0.75 3.50 0.75
Load factor for concrete design = 1.4

Design along longitudinal direction :

Max. Cant Bm at face of column = 16.2x(0.75-0.45)^2/2 0.7 kNm 73.65 KN/m per m run

Negative BM.at Center = 16.2x 3.5 ^2 /8 24.7 kNm 5.00 m


Factored Mu (+Ve) = 1.022 kNm
Factored Mu (-Ve) = 34.72 kNm
Foundation Depth D = 500 mm
Effective Depth d = 417 mm
Width B = 1000 mm
DESIGN OF FOUNDATION F4 UNBRACED BAY
Mu = 1.022 kNm Mu = 34.72 kNm
Mu/bd² = 0.006 N/mm² Mu/bd² = 0.200 N/mm²
pt = 0.100 % pt = 0.100 %
Bottom Reinf. Top reinforcement :
Reqd. Reqd.
Dia of spacing Ast Pro. Dia of rein spacing Ast Pro.
Mu/bd2 % pt Ast,mm2 spacing pt,prov Mu/bd2 % pt Ast,mm2 spacing pt,prov
rein bar provided mm2 bar provided mm2
mm mm
0.006 0.130 542.1 16 371 150 1340.413 0.32 0.20 0.13 542.1 16 371 150 1340.413 0.32

Max S.F along Z axis =16.2 x (0.75-0.9/2-0.417)x1 = 1.89 kN


Max factored Shear Stress = 0.01 N/mm² Tv=(Vu/bd)
pt, provided = 0.32 %
As per BS 8110-1:1997,Table 3.8 = 0.42 N/mm² OK
Design along transverse direction :
Effective Depth d = 403 mm (Self Wt. of Footing+Wt. of Surrounding Soil)
Max BM at face of column =16.2 x (1.75-0.4)^2/2 = 14.7 kNm 57.5 Kn/m per m run
Max Shear at distance d =16.2 x (1.75-0.8/2-0.403)x1 = 15.294 kN 1.75 1.75
Mu/bd2 = 0.127 N/mm2
pt Reinf. = 0.100
Bottom Reinforcement
Reqd.
Dia of spacing Ast Pro.
Mu/bd2 % pt Ast,mm2 spacing pt,prov
rein bar provided mm2
mm 73.65 kN/m per m run
0.127 0.13 523.90 12 216 150 753.9822 0.187 3.50
Top Reinforcement
Provide Minimum Steel = 0.13 x 1000 x 403 /100 = 483.6 mm2/ m run
Provide 12 mm dia at 150 c/c
Punching shear perimeter (U1),
Astprovided 753.98 mm2 / m run OK (Refer figure 3.23, BS-
(Pt)prov. 0.187 % 8110:1997)
Max factored Shear Stress =15.3x1.4x1000/(1000x403) = 0.05 N/mm2
1.5d
Allow. Shear Stress(Tc ) = 0.36 N/mm2 OK
Refer Table 3.8 BS 8110-1:1997 Punching shear perimeter (U0),
(Refer figure 3.23, BS-
Check for Punching Shear for U0 : 8110:1997)
For Punching Shear Critical Section is considered at '1.5d' from the face of column all around.
Factored vertical load in column = 242 kN
Perimeter of the critical section = 3400 mm
Effective depth = 403 mm
Factored Shear Stress = 0.22 N/mm2 OK
Shear Stress <.8Sqrt(Fck) & 5N/mm 2
Refer CL 3.7.7.2 BS 8110-1:1997
Check for Punching Shear for U1 :
For Punching Shear Critical Section is considered at '1.5d' from the face of column all around.
Factored vertical load in column = 242 kN
Perimeter of the critical section = 5617 mm
Effective depth = 403 mm
Factored Shear Stress = 0.13 N/mm2
Corrosponding τc = 0.36 N/mm2 OK
SHELL MARINA LOBP-GMP PROJECT

DESIGN CALCULATION FOR PIPE RACK PR5 - LOBP AREA

DESIGN OF COMBINED FOOTING CF1

ALLOW.GROSS S.B.C = 200 kN/m2


ALLOW. GROSS S.B.C (WIND CASE) = 250 kN/m2 Fck = 35 N/mm2
Unit Weight of Concrete = 25 kN/m2 Fy = 420N/mm2
Unit Weight of Soil = 18 kN/m3 Clear Cover at Top = 50mm
ALLOW. NET S.B.C = 160.5 kN/m2 Clear Cover at Bottom = 75mm
ALLOW. NET S.B.C (WIND LOAD) = 210.5 kN/m2 Height of pedestal = 2.10m
Depth of foundation below FGL = 2.00m
INCREASE IN SBC FACTOR FOR WIND LOAD = 1.25 Lz = 6.00m
Lx = 2.60m
t = 0.50m (Thickness of Footing)
P1x = 1.00m
P1z = 1.00m
X Foundation CG P2x = 1.00m
Load CG P2z = 1.00m
3.00

1.30 FGL
Lx = 2.60 ex 1.00
1.00 P1 P2
ez Z 2.00 m
1.30 1.00 1.00

0.50 m
1.50 1.50 1.50 1.50

Lz = 6.00
Self Wt of Footing W1 = 195.00 kN
Wt of soil above Fdn W2 =(L X B-P1x X P1y - P2x X P2y)X(H-t)X18 = 367.20 kN
Wt of pedestal W3 =P1XXP1ZXHx25+P2XXP2ZXHx25 = 105.00 kN
Total Wt. = 667.20 kN

20-007-CS-8180-00098 Revision 01Q Annexure - II Design Calculation of Combined Footing CF1 3 of 5


SHELL MARINA LOBP-GMP PROJECT

DESIGN CALCULATION FOR PIPE RACK PR5 - LOBP AREA

RCC Design (Self Wt. of Footing+Wt. of Surrounding Soil)


Design for 1m width of slab 39.5 kN/m P1 P2
Design for maximum net soil pressure under the footing 1.50 3.00 1.50
Load factor for concrete design = 1.5

Design along longitudinal direction :

Max. Cant Bm at face of column = 171.5x(1.5-0.5)^2/2 85.8 kNm 211.00 kN/m per m run

Negative BM.at Center = 171.5x 3 ^2 /8 -171.5x1.5^2/2 192.9 kNm 6.00 m


Factored Mu (+Ve) = 128.625 kNm
Factored Mu (-Ve) = 289.5 kNm
Foundation Depth D = 500 mm
Effective Depth d = 417 mm
Width B = 1000 mm
K = M/fcbd2 K = M/fcbd2
= 0.02113 = 0.047567
Z = Min(d((0.5+Sqrt(0.25-K/0.9)),0.95d) Z = Min(d((0.5+Sqrt(0.25-K/0.9)),0.95d)
= 396.15 mm = 393.6534 mm
As = M/0.87fyZ As = M/0.87fyZ
= 888.581 mm2 = 2012.64 mm2
Mu = 128.625 kNm Mu = 289.50 kNm
M/fcbd² = 0.021 N/mm² M/fcbd² = 0.048 N/mm²
pt = 0.130 % (Refer Table 3.25, SS CP65: Part1: 1999) pt = 0.130 %
Bottom Reinf. Top reinforcement :
Reqd. Reqd.
Dia of spacing Ast Pro. Dia of rein spacing Ast Pro.
Mu/fcbd² Min. % pt Ast,mm2 spacing pt,prov Mu/fcbd² Min % pt Ast,mm2 spacing pt,prov
rein bar provided mm2 bar provided mm2
mm mm
0.021 0.130 888.6 16 226 150 1340.413 0.32 0.05 0.13 2012.6 20 156 150 2094.395 0.5

Max S.F along Z axis =171.5 x (1.5-1/2-0.417)x1 = 99.98 kN


Max factored Shear Stress = 0.36 N/mm² Tv=(Vu/bd)
pt, provided = 0.32 %
For values of τc Refer Table 3.8, SS CP65: Part1: 1999 = 0.53 N/mm² OK
Design along transverse direction :
K = M/fcbd2
= 0.00984918
Z = Min(d((0.5+Sqrt(0.25-K/0.9)),0.95d)

20-007-CS-8180-00098 Revision 01Q Annexure - II Design Calculation of Combined Footing CF1 4 of 5


SHELL MARINA LOBP-GMP PROJECT

DESIGN CALCULATION FOR PIPE RACK PR5 - LOBP AREA

= 379.05 mm
As = M/0.87fyZ
= 396.231555 mm2

Width = 1000
Effective Depth d = 399 mm (Self Wt. of Footing+Wt. of Surrounding Soil)
Max BM at face of column =171.5 x (1.3-0.5)^2/2 = 54.9 kNm 39.5 kN/m per m run
Max Shear at distance d =171.5 x (1.3-1/2-0.399)x1 = 68.772 kN 1.30 1.30
Mu/fcbd² = 0.010 N/mm2
pt Reinf. = 0.130
Bottom & Top Reinforcement
Reqd.
Dia of spacing Ast Pro.
Mu/fcbd² Min. % pt Ast,mm2 spacing pt,prov
rein bar provided mm2
mm 211.00 kN/m per m run
0.010 0.13 396.23 20 793 150 2094.395 0.525 2.60

Max factored Shear Stress =68.78x1.5x1000/(1000x399) = 0.26 N/mm2


Allow. Shear Stress(Tc ) = 0.53 N/mm2 OK
For values of τc Refer Table 3.8, SS CP65: Part1: 1999

Check for Punching Shear

The shear capacity is checked first on a perimeter 1.5d1 from the face of column.
If the calculated shear stress does not exceed Design shear stress then
No further checks are required. (Refer Clause 3.7.7.7, SS CP65: Part1: 1999)

20-007-CS-8180-00098 Revision 01Q Annexure - II Design Calculation of Combined Footing CF1 5 of 5