Fault Code 155: Intake Manifold 1 Temperature - Data Valid But Above Normal Operating Range - Most Severe Level
Fault Code 155: Intake Manifold 1 Temperature - Data Valid But Above Normal Operating Range - Most Severe Level
Intake Manifold 1 Temperature - Data Valid But Above Normal Operating Range - Most
Severe Level
Fault Code: 155 Intake Manifold 1 Temperature - Possible reduced engine performance.
PID(P), SID(S): P105 Data Valid But Above Normal
SPN: 105 Operational Range - Most Severe
FMI: 0/0 Level. Intake manifold air
Lamp: Red temperature signal indicates
SRT: intake manifold air temperature
above engine protection critical
limit.
Circuit Description:
The Engine Control Module (ECM) provides 5 volts to the intake manifold temperature signal circuit, and monitors the
change in voltage caused by changes in the resistance of the sensor to determine the intake manifold temperature.
When the intake air is cold, the sensor (or thermistor) resistance is high. The ECM signal voltage only pulls down a
small amount through the sensor to a ground. Therefore, the ECM senses a high signal voltage or low temperature.
When the intake air is warm, the sensor resistance is low. The signal voltage pulls down a large amount. Therefore,
the ECM senses a low signal voltage, or a high temperature.
Component Location:
The intake manifold 1 pressure/temperature sensor is located in the air intake horn.
© 2008 Cummins Inc., Box 3005, Columbus, IN 47202-3005 U.S.A. Printed from QuickServe® Online.
All Rights Reserved. Last Modified: 19-Aug-2014
File: 176-fc155 Page 2 of 3
Conditions for Setting the Fault Codes:
The Engine Control Module (ECM) detected the intake manfiold air temperature was greater than 132°C [270°F] for 5
seconds.
Shop Talk:
The intake manifold air temperature sensor measures the temperature of the charge-air as it passes through the
intake manifold.
Possible causes of this fault code include:
• Restricted air flow through the charge-air cooler
• Undersized charge-air cooler
• High turbocharger compressor outlet temperature.
© 2008 Cummins Inc., Box 3005, Columbus, IN 47202-3005 U.S.A. Printed from QuickServe® Online.
All Rights Reserved. Last Modified: 19-Aug-2014
File: 176-fc155 Page 3 of 3
© 2008 Cummins Inc., Box 3005, Columbus, IN 47202-3005 U.S.A. Printed from QuickServe® Online.
All Rights Reserved. Last Modified: 19-Aug-2014