Inspektionreport
Service - Kom.
Report-Nr. 2 von 2 208707
Kunde: Alstom -Argentina Anlage: CPB Unit 30 Bahia Blanca
Ansprechpartner: Ricardo Sanchez Negrette Telefon-Nr.:
Kunden-Bestell-Nr.: tel. Fax: / E -Mail:
Hersteller: Babcock Vorort-Bez. : HP-Bypass Control-Valve
Armaturentyp: 342-152 AKZ / KKS : right site
Werk-Nr.: 4-84690-710 Bauteilkennzeichen:
DN E / A: 200 / 450 Seat 110 Gehäusewerkstoff :
reason of inspektion: visual examination
Report :
Valve komplet dismantled
inside parts cleaned and inspected
cage (pos.10) broken around 200 mm behind the seat
bodyseat have big pressuremarks
bodyseat grindet by HVS-2 system as god as possible
plug seat machined by lathe
assembled with new gaskets
after commissioning, tight the bolts (pos.71)

status
surface of the stem is damamaged by corrosion (pos. 20, 82) renew
bodyseat have pressuremarks and elutriations (pos. 16) renew
stuffigbox is in old disign (to mutch rings) , reequipment in new disign (pos. 22, 78)
repair of the cage is not possible (pos.10) renew
plese get in touch with Sempell to order spareparts soon as possible