Download as pdf or txt
Download as pdf or txt
You are on page 1of 106

PASOLINK NEO

INTRODUCTION

Provided for Training / June 2007

TOPC-E4010E-01-07371
TOPC-E4010E-01-07371 PASOLINK NEO 1
PASOLINK PDH FAMILY

FREQUENCY BAND 6GHz 7/8GHz 10/11GHz 13GHz 15GHz 18GHz 23GHz 26GHz 28GHz 32GHz 38GHz 52GHz

SERIES/MODEL MODULATION INTERFACE 5.925-7.125 7.125-8.5 10.15-11.7 12.75-13.25 14.2-15.35 17.7-19.7 21.2-23.6 24.25-27 27.5-29.5 31.8-33.4 37-40 51.4-52.6

PASOLINK V3 4PSK 2x2MB


4x2MB
8x2MB
16x2MB
1x8MB
1x34MB

PASOLINK V4 4PSK 4x2MB


2/4/8/16x2MB
(2x10/100Base-T)

4PSK+RS 10MB (5E1) QPSK


PASOLINK Mx 16QAM+RS 20MB (10E1)
40MB(20E1)
80MB(40E1)
(2x10/100Base-T)

PASOLINK NEO 4PSK+RS 10MB (5E1) QPSK


16QAM+RS 20MB (10E1)
32 QAM+RS 40MB(20E1)
80MB(40E1)
100MB(48E1)
1 / 2 E3
(2x10/100Base-T)
(4x10/100Base-T)
16E1 + DXC

16QAM + RS 8x2MB
PASOLINK+
16x2MB

1x34MB

TOPC-E4010E-01-07371 PASOLINK NEO 2


PASOLINK SDH FAMILY

FREQUENCY BAND 6 GHz 7/8GHz 10/11GHz 13GHz 15GHz 18GHz 23GHz 26GHz 28GHz 32GHz 38GHz
SERIES/MOD SYSTEM MODULATI INTERFAC 5.925- 7.125- 10.15- 12.75- 14.2- 17.7- 21.2- 24.25- 27.5- 31.8- 37-40
EL ON E 7.125 8.5 11.7 13.25 15.35 19.7 23.6 27 29.5 33.4

PASOLINK+ SDH 32QAM+RS 21x2MB


(STM-0) (STM-1)
SDH 32MLCM STM-1
(STM-1) +RS 2Port LAN
SDH 128QAM+R STM-1
(STM-1) S 2Port LAN

PASOLINK+ SDH 128QAM+R STM-1


(Enhanced) (STM-1) S 2Port LAN

SDH 128QAM+R STM-1


PASOLINK+ (2xSTM- S (XPIC)
(XPIC) 1) 2Port LAN
PASOLINK SDH 128QAM+R STM-1(E)
NEO (2XSTM- S STM-1(O)
1) (APS)
2Port LAN
GbEther
(XPIC)

TOPC-E4010E-01-07371 PASOLINK NEO 3


FEATURES
ADVANCED TECHNOLOGIES AND SUPERB PERFORMANCE

HIGH SPECTRUM EFFICIENCY / HIGH SYSTEM GAIN

FREQUENCY AGILITY AND EASY TUNING

CONFORMITY WITH ANSI, ITU-R, ITU-T AND ETSI STANDARDS

ELECTRO MAGNETIC COMPATIBILITY (EMC)

EASY AND QUICK INSTALLATION

TX POWER CONTROL

MULTIPLE SERVICE CHANNELS

SYSTEM FLEXIBILITY

EASY MAINTENANCE FACILITIES

PASOLINK NETWORK MANAGEMENT SYSTEM (PNMSj) (OPTION)

PASOLINK NETWORK MANAGEMENT TERMINAL (PNMTj) (OPTION)

TOPC-E4010E-01-07371 PASOLINK NEO 4


FEATURES-1

ADVANCED TECHNOLOGIES AND SUPERB PERFORMANCE

• MMIC, HIC AND VLSI

• Low Power Consumption

• 10Base-T/100Base-TX, 1000Base-SX, 1000Base-T (LAN Interface)

• High reliability and Quality

• APS for STM-1 Optical Interface

• Excellent field proven MTBF

• PDH Cross Connect


• Nodal solutions (future) E1 Line Digital Cross Connect

TOPC-E4010E-01-07371 PASOLINK NEO 5


FEATURES-2
HIGH SPECTRUM EFFICIENCY / HIGH SYSTEM GAIN

• High Spectrum efficiency


QPSK to 128 QAM modulation (S/W selectable)
• High Performance LNA-MIX (Superior receiver sensitivity)

• High System Gain achieved by:


Forward Error Correction
Base Band Linearizer

FREQUENCY AGILITY AND EASY TUNING


• Field tunable local oscillators (Synthesizer)

• RF Point Frequency can be changed through Local Craft Terminal (LCT)

• ODU Sub-band changeable by simply replacing the RF Filter.

TOPC-E4010E-01-07371 PASOLINK NEO 6


FEATURES-3
CONFORMITY WITH ANSI, ITU-R, ITU-T AND ETSI STANDARDS
ETSI STANDARDS
ITU-T STANDARDS
ITU-R, STANDARDS
ANSI STANDARDS
ELECTRO MAGNETIC COMPATIBILITY (EMC)

• Complies with ETS EN301 489-4

EASY AND QUICK INSTALLATION

• Very compact and light ( 1+1 IDU only 1 rack unit size)
• Only one coaxial cable interconnection
• Automatic Cable Equalization
• Different mounting methods for IDU, ODU and Antenna
• Easy antenna pointing adjustments (RX level monitor point in ODU)

TOPC-E4010E-01-07371 PASOLINK NEO 7


FEATURES-4

TX POWER CONTROL

• Automatic Transmit Power Control (ATPC) or


• Manual Transmit Power Control (MTPC)
• Variable : from 0 up to 30 dB, in 1 dB steps (6-52 GHz)
(Depending on the Frequency and Modulation scheme)

MULTIPLE SERVICE CHANNELS


• Engineering Order Wire (OW)
• Digital Service Channels - Two RS-232C
Two V.11 (Contra/Co direction selectable)

• WS E1 & SC LAN (64/128/256/2048Kbps) (Depend on the INTFC Card used)

• NMS Service Channel for PASOLINK Monitoring

• In SDH configuration access to E1, F1, DCCr bytes in the STM-1 SOH
TOPC-E4010E-01-07371 PASOLINK NEO 8
FEATURES - 5
SYSTEM FLEXIBILITY

• (1 + 0 ) unprotected or ( 1+ 1) protected using the same IDU

• Hot Standby/ Space Diversity / Twin Path systems are available with Hitless switch

• Common IDU for different RF frequencies (6/7/8/10/11/13/15/18/23/26/28/32/38/52GHz)

• Software variable transmission bit rates and modulation


(QPSK/16QAM/32QAM/128QAM)
• Common ODU for different bit rates (5 to 48E1, 1 to 2 E3, 155Mbps, 2x155Mbps)

• Common IDU and ODU for PDH/SDH/LAN including 2xSTM-1 XPIC

• Common IDU and ODU for Repeater with 16E1 DXC interface card

• Wide input line voltage -40.5~57Vdc (optional Power supply Interface +/- (20 ~ 60)Vdc)

TOPC-E4010E-01-07371 PASOLINK NEO 9


FEATURES - 6
EASY MAINTENANCE FACILITIES

• Full front panel access for all cabling and user interfaces

• Near End, Far End Base-band Loop back + IF Loop back facilities

• OW calling facility between IDU – IDU Party Line

• Pre-settable BER alarm point: 10-3, 10-4 10-5 or 10-6 (alarm and AIS injection)

• Easy Local monitor and maintenance using LCT (USB connection & IE Browser)

• Local and Remote monitoring of IDU & ODU operating condition from PNMTj

• Network Monitor by PNMSj or PC-MG

TOPC-E4010E-01-07371 PASOLINK NEO 10


FEATURES - 7
PASOLINK NETWORK MANAGEMENT SYSTEM (PNMSj) (OPTION)
• User friendly operation

• Free from OS limitations, PNMSj runs on both Windows and UNIX

• Remote access and control of any PASOLINK Terminal in the network

• Link oriented monitor and control ( both sides of a microwave link)

• Multi level security

• Real Time Event Logging and Event History

• ITU-T G.826/G.828 Performance Monitor (Table /graph presentation)

• Auto Discovery of NEO Network Elements

• SNMP Interface (Option)

• Real-time monitor of Network Elements (NE)

• Monitor & Control using Remote Client


TOPC-E4010E-01-07371 PASOLINK NEO 11
FEATURES - 8
PASOLINK NETWORK MANAGEMENT TERMINAL (PNMTj) (OPTION)

• User friendly operation as maintenance terminal

• Link oriented monitor and control for both Local and Remote terminals

• Uses Windows XP/2000 with mobile PC

• NE Setup and Provisioning

• NE Network property setting

• Configuration & Program file download/upload

TOPC-E4010E-01-07371 PASOLINK NEO 12


SYSTEM & MODULATION

SDH
SDH

PDH
PDH LAN
LAN

QPSK 128QAM
128QAM
QPSK

16QAM
16QAM 32QAM
32QAM
TOPC-E4010E-01-07371 PASOLINK NEO 13
TRANSMISSION CAPACITY

20Mbps

10Mbps 40Mbps

2x156Mbps 80Mbps

156Mbps 100Mbps

TOPC-E4010E-01-07371 PASOLINK NEO 14


TRANSMISSION CONFIGURATIONS

(1+1)

(1+0) SD

2x(1+1) TwinPath

2x(1+0) Repeater

TOPC-E4010E-01-07371 PASOLINK NEO 15


NEO CAPABILITY

Modulation
256QAM

128QAM •
STM-1
XPIC
64QAM
PASOLINK NEO


(Standard version)
32QAM
100MB/48E1

16QAM • • • •
5E1 10E1 20E1 40E1

8PSK
5E1 10E1 20E1
4PSK • • •
0 3.5 7.0 14.0 28.0 40.0 56.0 [MHz]
Adjacent CH Spacing
TOPC-E4010E-01-07371 PASOLINK NEO 16
NEO CAPABILITY

INTF Card Bitrate 16E1 16E1 48E1 4Port STM-1 STM-1 2Port GbE GbE
(Number of E1s) DXC Ether Elec. Opt.S1/L.1 LAN SX LX
1 10Mbps(5E1) ○ ○ ○ ○ --- --- --- --- ---
2 20Mbps(10E1) ○ ○ ○ ○ --- --- --- --- ---
3 40Mbps(16E1) ○ ○ --- --- --- --- --- --- ---
3’ 40Mbps(20E1) ○ ○ ○ ○ --- --- --- --- ---
4 80Mbps(40E1) ○ ○ ○ ○ --- --- --- --- ---
5 100MB(48E1) ○ ○ ○ --- --- --- --- ---
5 STM-1 --- --- --- ○ ○ ○ ○ ○

Ethernet

Capacity (E1/STM-1) 5E1 10E1 20E1 40E1 48E1 STM-1


Transmission capacity (Mbps) 10 20 40 80 100 155
Modulation Scheme Channel Separation (MHz)
QPSK 7 14(13.75) 28(27.5)
16QAM 3.5 7 14(13.75) 28(27.5)
32QAM 28(27.5)
128QAM 28(27.5)
16E1 +2Port LAN
16E1 +2Port LAN with DXC
48 X E1 Module
4 port LAN
CHANGE MODULE
STM-1 Module
2 port LAN
Gb Ether

TOPC-E4010E-01-07371 PASOLINK NEO 17


LAN Function Summary

2way ASYNC LAN/WS INTFC LAN/WS INTFC


Interface Card 16E1 INTFC E3 INTFC 4P LAN INTFC GbE INTFC
DXC (MAIN SLOT) (SUB SLOT)

10BASE-T 10BASE-T 10BASE-T 10BASE-T 10BASE-T 10BASE-T 1000BASE-SX


Interface
100BASE-TX 100BASE-TX 100BASE-TX 100BASE-TX 100BASE-TX 100BASE-TX 1000BASE-T

Number of LAN Port 2 (RJ-45) 2 (RJ-45) 2 (RJ-45) 4 (RJ-45) 2 (RJ-45) 2 (RJ-45) 1 (SFP or RJ-45)

64/128/256 Kbps
Supported Capacity PDH(10M~80M) PDH (40 ~ 80 M) PDH(10M~80M) PDH(100M) SDH(156M) SDH(156M)
(2 Mbps)*

80Mbps(Main) 16Mbps (WS) 80Mbps(Main) 100Mbps(Main) 150Mbps(Main) 150Mbps(Main)


Maximum Throughput 2Mbps (WS/SC)
256Kbps(SC) 256 Kbps (SC) 256Kbps(SC)

Maximum Frame Length 1548 bytes 1548 bytes 1548 bytes 1548 bytes 1548 bytes 1548 bytes 9600 bytes

RMON O O O O O O O

2WAY DXC (Async.) X X O X X X X

O: Supported X: Not Available

TOPC-E4010E-01-07371 PASOLINK NEO 18


APPLICATIONS

TOPC-E4010E-01-07371 PASOLINK NEO 19


APPLICATIONS

TOPC-E4010E-01-07371 PASOLINK NEO 20


PDH – CROSS CONNECT
Air Capacity
Max. 80Mbps(40E1)

16E1+LAN

2x8E1(D-Sub)

TERMINAL - DXC 2 WAY -TREE


A) Term DXC C) 2way-tree
Dir-A
Dir-B Dir-A
Rep

DXC
DXC Dir-A > Dir-B
D/I for A
D/I for A

2 WAY -STAR 2 WAY -REPEATER


B) 2way-Star D) 2way-Rep
Dir-B Dir-A
Dir-B Dir-A
Rep

DXC DXC Dir-A >= Dir-B Dir-A = Dir-B


D/I = 0
D/I for B D/I for A

TOPC-E4010E-01-07371 PASOLINK NEO 21


ETHERNET CONFIGURATION

TOPC-E4010E-01-07371 PASOLINK NEO 22


NETWORK MONITORING SYSTEM
Web based Client/Server concept Upper NMS
Server Mode
Remote Terminal

Remote
Client

PNMTj

Remote
Client

PNMTj
PNMTj

In addition to the 15 Remote Clients, one more Remote Terminal can be configured
with Server Mode. Server Mode allows network configuration functions.

TOPC-E4010E-01-07371 PASOLINK NEO 23


TOPC-E4010E-01-07371 PASOLINK NEO 24
PASOLINK (1+0) SYSTEM

(Blank) (Blank)

(Blank)

PASOLIN NEO (FRAME)

PASOLIN NEO (1+0) COMMON MODULES

TOPC-E4010E-01-07371 PASOLINK NEO 25


PASOLINK (1+0) SYSTEMS PDH

PASOLIN NEO (1+0) WITH PDH 16E1 + 2PORT LAN INTFC

PASOLIN NEO (1+0) PDH WITH 48E1 INTFC

PASOLIN NEO (1+0) PDH WITH E3 + WS and 2Port LAN INTFC

PASOLIN NEO (1+0) PDH WITH 4 Port LAN INTFC + E1

TOPC-E4010E-01-07371 PASOLINK NEO 26


PASOLINK (1+1) SYSTEMS PDH

PASOLIN NEO (1+1) WITH PDH 16E1+2Port LAN INTFC

PASOLIN NEO (1+1) WITH PDH 48E1 INTFC

PASOLIN NEO (1+1) with PDH E3 INTFC + WS and 2Port LAN INTFC

PASOLIN NEO (1+1) PDH WITH 4 Port LAN INTFC + E1

TOPC-E4010E-01-07371 PASOLINK NEO 27


PASOLINK (1+0) SYSTEMS SDH

PASOLIN NEO (1+0) WITH STM-1 (Electrical) INTFC

PASOLIN NEO (1+0) WITH STM-1 (Optical) INTFC

PASOLIN NEO (1+0) WITH STM-1 (Optical) INTFC (APS CONFIGURATION)

PASOLIN NEO (1+0) WITH STM-1 (Optical) INTFC AND WS/SC LAN INTFC

TOPC-E4010E-01-07371 PASOLINK NEO 28


PASOLINK NEO (1+1) SYSTEMS SDH

PASOLIN NEO (1+0) WITH STM-1 (Electrical) INTFC

PASOLIN NEO (1+0) WITH STM-1 (Optical) INTFC

PASOLIN NEO (1+0) WITH STM-1 (Optical) INTFC

PASOLIN NEO (1+0) WITH STM-1 (Optical) INTFC with WS/SC LAN

TOPC-E4010E-01-07371 PASOLINK NEO 29


PASOLINK NEO XPIC CONFIGURATION

PASOLIN NEO (1+0) WITH 2x STM-1 INTFC with XPIC

PASOLIN NEO (1+1) WITH 2x STM-1 INTFC with XPIC

TOPC-E4010E-01-07371 PASOLINK NEO 30


PASOLINK NEO OTHER CONFIGURATIONS

PASOLIN NEO (1+1) WITH PDH 16E1+2Port LAN INTFC AND 2 WAY / XC
OPT

PASOLIN NEO (1+0) WITH GbE INTFC with WS/SC LAN (SDH)

M.S

PASOLIN NEO (1+0) WITH 2 PORT LAN INTFC (SDH)

PASOLIN NEO (1+0) WITH DC-DC CONV (PDH & SDH)

TOPC-E4010E-01-07371 PASOLINK NEO 31


PASOLINK NEO IDU MODULES
6

2 4 5
1
3 7

PASOLINK NEO IDU RACK AND MODULES

NO. CODE NO. MODULE NAME REMARKS

1 H2931 RACK COMMON

2 H2940 MODEM COMMON (1+0)

3 H2940 MODEM COMMON (1+1)

3 H3040 DC-DC CONV COMMON (1+0) (with EHG ODU)

4 H2960 [A] STM-1 INTFC Electrical SDH Main Slot

4 H2960 [B] STM-1 INTFC Optical (S 1.1) SDH Main Slot

4 H2960 [C] STM-1 INTFC Optical (L 1.1) SDH Main Slot

4 H2965 [C] LAN / WS INTFC SDH Main Slot (2 Port LAN)

4 H3021 [A] GbE INTFC (1000 BASE-SX /1000 BASE-T) SDH Main Slot

4 H3021 [C] GbE INTFC (1000 BASE-LX/1000 BASE-T) SDH Main Slot

5 H2960 [B] STM-1 INTFC Optical (S 1.1) SDH Sub-Slot (APS)

5 H2960 [C] STM-1 INTFC Optical (L 1.1) SDH Sub-Slot (APS)

5 H2965 [A] LAN / WS INTFC SDH Sub-Slot (WS/SC LAN)

5 H2965 [B] LAN / WS INTFC SDH Sub-Slot (WS)

5 H2965 [C] LAN / WS INTFC SDH Main (2 PORT LAN) / Sub-Slot (WS/SC LAN)

6 H2980 [A] 16E1 INTFC + 2 Port LAN PDH

6 H2980 [B] 16E1 E/W 2 Way DXC INTFC PDH With 2 Port LAN

6 H3000 48E1 INTFC PDH

6 H3010 E3 INTFC PDH Two E3, up to 8 WS

6 H3020 4P LAN INTFC PDH With E1s

7 H2950 CTRL COMMON

TOPC-E4010E-01-07371 PASOLINK NEO 32


PASOLINK NEO PDH BLOCK DIAGRAM

PASOLIN NEO (1+1) (PDH)

PASOLIN NEO (1+0) (PDH)

*.OPTION

TOPC-E4010E-01-07371 PASOLINK NEO 33


PASOLINK NEO SDH BLOCK DIAGRAM

PASOLIN NEO (1+1) (SDH)

PASOLIN NEO (1+0) (SDH)

*OPTION 1. STM-1 ELECTRICAL OR OPTICAL OR LAN

2. STM-1 OPTICAL ON SUB SLOT FOR APS

3. WS/ LAN AUXILIARY SIGNALS

TOPC-E4010E-01-07371 PASOLINK NEO 34


PASOLINK NEO XPIC (SDH) BLOCK DIAGRAM
PASOLIN NEO (1+0) FOR XPIC (SDH)

*OPTION 1. STM-1 ELECTRICAL OR OPTICAL OR LAN

2. STM-1 OPTICAL ON SUB SLOT FOR APS

3. WS/ LAN AUXILIARY SIGNALS

TOPC-E4010E-01-07371 PASOLINK NEO 35


PASOLINK NEO REPEATER BLOCK DIAGRAM
PASOLIN NEO TWO WAY XC CONFIGURATION FOR PDH

*OPTION

TOPC-E4010E-01-07371 PASOLINK NEO 36


TOPC-E4010E-01-07371 PASOLINK NEO 37
PERFORMANCE
ITEM 6-7GHz 8GHz 10-11GHz 13 GHz 15 GHz 18 GHz 23 GHz 26 GHz 28GHz 32GHz 38GHz 52 GHz

Transmit Power Measured at ODU TX port

Guaranteed TX Power 128QAM 25 25 21 21 21 19 19 18 18 17 14.5 -

6-38 GHz +/- 1.5 dB 32QAM 25 25 21 21 21 19 19 18 18 17 14.5 -

6-38 GHz +/- 1.5 dB 16QAM 27 27 21.5 22.5 22.5 22 22 20 18 17 14.5 -

6-38 GHz +/- 1.5 dB QPSK 29 29 25 25 23 24 24 22 22 22 18 3

6-26GHz +/- 1.5dB Receiver Threshold Measured at ODU RX port (dBm)t at 10 BER [BER at 10 value below -1.5 dB]
-6 -3

28-52GHz +1.5/-2.5 dB
156MB/128 QAM -69.5 -69.5 -68.5 -68.5 -69.0 -69.0 -69.0 -68.5 -68.5 -67.0 -67.0 -

100MB/32QAM -75.0 -75.0 -74.5 -74.5 -75.0 -75.0 -75.0 -74.5 -74.5 -73.0 -73.0 -
Guaranteed Threshold 80MB/16QAM -77.0 -77.0 -76.0 -76.0 -76.5 -76.5 -76.5 -76.0 -76.0 -74.5 -74.5 -
Rx Threshold at 10-6 BER 40MB/16QAM -80.0 -80.0 -79.0 -79.0 -79.5 -79.5 -79.5 -79.0 -79.0 -77.5 -77.5 -
6-52 GHz +3 dB 20MB/16QAM -83.0 -83.0 -82.0 -82.0 -82.5 -82.5 -82.5 -82.0 -82.0 -80.5 -80.5 -

10MB/16QAM -86.0 -86.0 -85.0 -85.0 -85.5 -85.5 -85.5 -85.0 -85.0 -83.5 -83.5 -
Rx Threshold values given
are with the ODU mounted 40MB/QPSK -84.0 -84.0 -83.0 -83.0 -83.5 -83.5 -83.5 -83.0 -83.0 -81.5 -81.5 -78.0
directly to the antenna for
(1+0) or (1+1) two antenna 20MB/QPSK -87.0 -87.0 -86.0 -86.0 -86.5 -86.5 -86.5 -86.0 -86.0 -84.5 -84.5 --81.0
configuration.
10MB/QPSK -90.0 -90.0 -89.0 -89.0 -89.5 89.5 -89.5 -89.0 -89.0 -87.5 -87.5 -84.0
For (1+1) configuration with
one Antenna, the losses in System Gain Measured at ODU RX port at 10 BER [BER at 10 value below +1.5 dB]
-6 -3

the Hybrid combiner/divider 156MB/128 QAM 94.5 94.5 89.5 89.5 90.0 88.0 88.0 86.5 86.5 84.0 81.5 -
must be considered.
Typically about 7dB loss in 100MB/32QAM 100.5 100.5 95.5 95.5 96.0 94.0 94.0 92.5 92.5 90.0 87.5 -
the link.
80MB/16QAM 103.0 103.0 97.5 98.5 99.0 98.5 98.5 96.0 94.0 91.5 89.0 -
Guaranteed System Gain 40MB/16QAM 106.0 106.0 100.5 101.5 102.0 101.5 101.5 99.0 97.0 94.5 92.0 -
128QAM: 6-38 GHz -3 dB 20MB/16QAM 109.0 109.0 103.5 104.5 105.0 104.5 104.5 102.0 100.0 97.5 95.0 -
32QAM: 6-38 GHz -3 dB 10MB/16QAM 112.0 112.0 106.5 107.5 108.0 107.5 107.5 105.0 103.0 100.5 98.0 -
16 QAM: 6-38 GHz -3 dB 40MB/QPSK 113.0 113.0 108.0 108.0 106.5 107.5 107.5 105.0 105.0 103.5 99.5 81.0
QPSK: 6-26GHz -3 dB 20MB/QPSK 116.0 116.0 111.0 111.0 109.5 110.5 110.5 108.0 108.0 106.5 102.5 84.0
28-52GHz -4 dB
10MB/QPSK 119.0 119.0 114.0 114.0 112.5 113.5 113.5 111.0 111.0 109.5 105.5 87.0

TOPC-E4010E-01-07371 PASOLINK NEO 38


PERFORMANCE
6GHz 7-8GHz 10-11GHz 13 GHz 15 GHz 18 GHz 23 GHz 26 GHz 28GHz 32GHz 38GHz 52 GHz

5.925-7.125 7.125-8.5 10.15-11.7 12.75-13.25 14.2-15.35 17.7-19.7 21.2-23.6 24.2-27 27.5-29.5 31.8-33.4 37-40 51.4-52.6

Direct Mount N/A N/A NEC ORIGINAL

N-TYPE N-TYPE
Remote Mount PDR 100 PBR 120 PBR 140 PBR 220 PBR 220 PBR 260 PBR 320 PBR 320 PBR 320
PDR 70 PDR 84

FREQUENCY STABILITY +/- 6 ppm (Guaranteed: +/- 10 ppm)

QPSK 29 29 25 25 23 24 24 22 22 22 18 3

TX PWR 16QAM 27 27 21.5 22.5 22.5 22 22 20 18 17 14.5 -


(dBm) 32QAM 25 25 21 21 21 19 19 18 18 17 14.5 -

128QAM 25 25 21 21 21 19 19 18 18 17 14.5

QPSK 0 – 30 dB 0 – 25 dB 0-10dB
TX PWR 16QAM 0 -24 dB
Control
(1 dB Step) 32QAM 0 – 23 dB

128QAM 0 – 20 dB

IFL signals (IDU-ODU) TX IF : 340 MHz RS IF: 140 MHz, Control signal : 10 MHz (5 MHz Ref: XPIC only)

Max RSL QPSK RF RX Level -15 dBm ( no error) / Residual BER: Less than 10-12 at RSL = -30 dBm
and
Residual 16QAM RF RX Level – 20dBm for the BER less than 10-3 / Residual BER: Less than 10-12 at RSL = -30 dBm
BER
32QAM RF RX Level – 20dBm for the BER less than 10-3 / Residual BER: Less than 10-12 at RSL = -30 dBm

128QAM RF RX Level – 20dBm for the BER less than 10-3 / Residual BER: Less than 10-12 at RSL = -30 dBm

DC Power -48 V DC (-40.5 TO 57 V DC)

TOPC-E4010E-01-07371 PASOLINK NEO 39


PERFORMANCE - PDH
SYSTEM PERFORMANCE (PDH)

CAPACITY UPTO 100MBPS

D-Sub 37: 16E1/ MDR68: 48E1/ IEC 169-29 (1.0/2.3) E3


INTERFACE
RJ-45 (2/4 Ports) LAN: 10/100Base-T(X)

Inter connecting ODU Side: N Type female, 50 ohms (Coaxial)


Connector, Cable IDU Side: TNC Type female, 50 ohms (Coaxial)
Impedance and cable 300 m (in case of 8D-FB cable or equivalent cable)
length

QPSK 7 MHz, 14 (13.75) MHz, 28 (27.5) MHz

16QAM 3.5 MHz, 7 MHz, 14 (13.75) MHz, 28 (27.5) MHz


CH SPACING
32QAM 28 (27.5) MHz

128 QAM N/A

Guaranteed operation ODU:-33 TO + 50 OC IDU: -5 TO + 50 OC

Workable operation ODU:-40 TO + 55 OC IDU: -10 TO + 55 OC


Environmental
requirement Transportation/storage IDU, ODU:-40 TO + 70 OC

Relative humidity ODU: 100% Applicable


IDU: Less than 90% at +50 OC(non-condensing)

EMC Conforms to EN 301 489-4

Safety Conforms to EN 60950

Power Requirement -48VDC (-40.5 to -57 VDC), Conforms to EN300 132-2

ODU Unit 30W (6 to 11 GHz) 23W (13 to 52 GHz)


Power Consumption
IDU Cards Modem: 10W, 48E1 INTFC: 8W, 16E1 INTFC: 8W, E3 INTFC : 8W, CTRL: 7W

Weight/ Card Modem: 0.5kg, 48E1 INTFC: 0.4kg, 16E1 INTFC: 0.4kg, E3 INTFC: 0.4kg, CTRL: 0.4kg

ODU 237(W) x 237 (H) x 101 (D) mm: Approx. 3.5 KG/UNIT
Mechanical Dimensions
IDU 482 (W) x 44 (H) x 240 (D) mm: Approx. 4 kg

Note: 13.75 or 27.5 MHz is applied for 18 GHz / LAN is not available on 48 E1 INTFC

TOPC-E4010E-01-07371 PASOLINK NEO 40


PERFORMANCE - SDH
SYSTEM PERFORMANCE (SDH)

CAPACITY STM-1: 155 Mbps, (up to 2 x STM-1) LAN : Up to 150 Mbps

Optical: LC, Electrical: IEC 169-29 (1.0/2.3)


Interface
LAN, RJ-45 (2 Ports) : 10/100 Base-T(X) , RJ-45: 1000 Base-T, LC: 1000 Base-SX

Inter connecting ODU Side: N Type female, 50 ohms (Coaxial)


Connector, Cable IDU Side: TNC Type female, 50 ohms (Coaxial)
Impedance and cable 300 m (in case of 8D-FB cable or equivalent cable)
length

QPSK N/A

16QAM N/A
CH SPACING
32QAM N/A

128 QAM 28 (27.5) MHz

Guaranteed operation ODU:-33 TO + 50 OC IDU: -5 TO + 50 OC

Workable operation ODU:-40 TO + 55 OC IDU: -10 TO + 55 OC


Environmental
requirement Transportation/storage IDU, ODU:-40 TO + 70 OC

Relative humidity ODU: 100% Applicable


IDU: Less than 90% at +50 OC(non-condensing)

EMC Conforms to EN 301 489-4

Safety Conforms to EN 60950

Power Requirement -48VDC (-40.5 to -57 VDC), Conforms to EN300 132-2

ODU Unit 30W (6 to 11 GHz) 23W (13 to 52 GHz)


Power Consumption
IDU Cards Modem: 10W, STM-1O INTFC: 8W, 16E1 INTFC: 8W, E3 INTFC : 8W, CTRL: 7W

Weight/ Card Modem: 0.5kg, 48E1 INTFC: 0.3kg, STM-1E INTFC: 0.3kg, LAN/WS INTFC: 0.3kg,
CTRL: 0.4kg

ODU 237(W) x 237 (H) x 101 (D) mm: Approx. 3.5 KG/UNIT
Mechanical Dimensions
IDU 482 (W) x 44 (H) x 240 (D) mm: Approx. 4 kg

Note: 27.5 MHz IS APPLIED FOR 18 GHz, / 2x 155 Mbps using 2 sets for XPIC / Two STM-1 Optical Interfaces for APS

TOPC-E4010E-01-07371 PASOLINK NEO 41


CTRL MODULE

MODEM MODULE

TOPC-E4010E-01-07371 PASOLINK NEO 42


CTRL MODULE – CONNECTORS & SWITCHES
CTRL MODULE IN THE PASOLINK NEO MONITOR THE OPERATING STATUS OF OTHER
MODULES IN THE IDU . AND CONTROL THE MODULES ACCORDING TO THE SETUP
INFORMATION. IT INTERFACE THE EXTERN ALARMS & CONTROLS, CLUSTER ALARMS,
BACK TO BACK CONNECTIONS, NMS CONNECTION AS WELL AS INTERFACING THE LCT
AND PNMTj.
CTRL MODULE CONTAIN THE ALL THE MANAGEMENT FUNCTIONS OF THE NE . IT ALSO
CONTAINS THE SNMP AGENT, MIB AND SOFTWARE FOR HANDLING ITS OWN ALARMS
AND COLLECTING STATISTICAL DATA.
CTRL MODULE STORE THE NETWORK CONFIGURATION & EQUIPMENT CONFIGURATION
FILES

EOW JACK

NE (RJ-45) OW HEAD SET CONNECTION

BACK TO BACK LAN CONNECTION

NMS (RJ-45) MMC SLOT


CONNECT TO PNMS (ROOT NE) MMC MEMORY CARD SLOT
BACK TO BACK LAN CONNECTION

LCT (USB-B) PROTECT SW CALL BUTTON


LCT CONNECTION ON - FOR UP LOADING EQUP CFG FILE TO MEMORY CARD OW CALL BUTTON
PNMT CONNECTION ON - FOR DOWN LOADING EQUP CFG FROM MEMORY CARD
ON - WHEN REMOVING AND MOUNTING CTRL WITH POWER ON
OFF - FOR NORMAL OPERATION

TOPC-E4010E-01-07371 PASOLINK NEO 43


CTRL MODULE - INDICATORS

MAINT LED
MAINT MODE ON
Fast Blink: data transfer to / from Memory Card
MEMORY LED
Slow Blink: Protect SW ON for CTRL Card replacement
ON: Enable Access to Memory Card
Blinks: Accessing Memory Card
OFF: Disable access to MMC Card

IDU LED
IDU Summary Alarm
Blinks: CPU or Peripheral event occurred
Modem unit alarms
Any INTFC module alarm
CTRL module alarm

TOPC-E4010E-01-07371 PASOLINK NEO 44


CTRL MODULE- CONNECTORS
1 NMS TXD(+) 1 NMS TXD(+)
2 NMS TXD (-) 2 NMS TXD (-)
3 NMS RXD (+) 3 NMS RXD (+)
4 Not Connected 4 Not Connected
1 Vbus 5 Not Connected 5 Not Connected
2 D (-) 6 NMS RXD (-) 6 NMS RXD (-)
3 D (+) 7 Not Connected 7 Not Connected
4 Ground 8 Not Connected 8 Not Connected
LCT (USB-B) NMS (RJ-45) NE (RJ-45)

ALM / AUX IN/OUT (High Density D-Sub 44 Pins, Female) SC IN/OUT (High Density D-Sub 44 Pins, Female)
1 EOW input 1(+) 16 EOW input 1(-) 31 CALL OUTPUT 1 1 NE2 TXD(+) 16 NE2 RXD (TERM) 31 NE2 RXD(-)
2 EOW output 1 (+) 17 EOW output 1 (-) 32 BUZZER INPUT 2 2 NE2 TXD(-) 17 Ground 32 Ground
3 EOW input 2 (+) 18 EOW INOUT 2(-) 33 CALL OUTPUT 2 3 GROUND 18 Ground 33 V.11-1 FP input(+)
4 EOW output 2 (+) 19 EOW output 2 (-) 34 4 V.11-1 Data in(+) 19 V.11-1 clock in(+) 34 V.11-1 FP input(-)
5 Ground 20 RL-6 (COM) 35 RL-6 (NC) 5 V.11-1Data in(-) 20 V.11-1 clock in (-) 35 V.11-1 FP output(+)
6 RL-6 (NO) 21 RL-5 (COM) 36 RL-5 (NC) 6 V.11-1 Data out(+) 21 V.11-1 clock out(+) 36 V.11-1 FP output(-)
7 RL-5 (NO) 22 RL-4 (COM) 37 RL-4 (NC) 7 V.11-1Data out(-) 22 V.11-1 clock out(-) 37 V.11-2 FP input(+)
8 RL-4 (NO) 23 RL-3 (COM) 38 RL-3 (NC) 8 V.11-2 Data in(+) 23 V.11-2 clock in(+) 38 V.11-2 FP input(-)
9 RL-3 (NO) 24 RL-2 (COM) 39 RL-2 (NC) 9 V.11-2Data in(-) 24 V.11-2 clock in (-) 39 V.11-2 FP output(+)
10 RL-2 (NO) 25 RL-1 (COM) 40 RL-1 (NC) 10 V.11-2 Data out(+) 25 V.11-1 clock out(+) 40 V.11-2 FP output(-)
11 RL-1 (NO) 26 HK4/CLST3 INPUT(-) 41 HK6/CLST4 INPUT(-) 11 V.11-2 Data out(-) 26 V.11-1 clock out(-) 41 RS232C-1 data out(+)
12 HK2 INPUT(-) 27 HK4/CLST3INPUT(+) 42 HK6/CLST4 INPUT(+) 12 RS-232C-1Data in 27 Ground 42 RS232C-1 data out(-)
13 HK2 INPUT(+) 28 HK3/CLST4 INPUT(-) 43 HK5/CLST3 INPUT(-) 13 RS-232C-1Data in (G) 28 Ground 43 RS232C-2 data out(+)

14 HK1 INPUT(-) 29 HK3/CLST4 INPUT (+) 44 HK5/CLST3 INPUT(+) 14 RS-232C-2Data in 29 Ground 44 RS232C-2 data out(-)

15 HK1 INPUT(+) 30 BUZZER INPUT 1 15 RS-232C-2Data in (G) 30 NE2 RXD (+)

TOPC-E4010E-01-07371 PASOLINK NEO 45


NEO CTRL Interface

LCT/PNMT PNMS/NE MMC Slot


USB Type B RJ-45

SV1
Radio SV line
SV2 4 3
384kbps
NMS
SW
2
HUB
Port Name Role
NE LAN CPU NMS (EM1) This port is used for PNMSj or Back –to Back 10Base-
1 5 T( Half duplex)
CONT
NE (EM2) This port is used for Back-to-Back equipment connection.
Store & forward
ASYNC (NE2) 19.2kbps
ASYNC
ASYNC
USB LCT/PNMT

USB NEO SV1 This port is used for radio connection of equipment.

SV2 In 2-WAY composition, this port is used.

TOPC-E4010E-01-07371 PASOLINK NEO 46


MODEM

QPSK/16QAM/32QAM/128QAM MODULATION/DEMODULATION
SYSTEM POWER ON/OFF
IDU POWER SUPPLY
FORWARD ERROR CORRECTION RS (INTERLEAVER)
HIGH BER/LOW BER DETECTION
EQUALIZATION USING TRANSVERSAL EQUALIZER
BB LINEARIZER
XPIC FUNCTION FOR DUAL POL TRANSMISSION
REF OSCILLATOR FOR XPIC ODU SYNCHRONIZATION

Transmission
MODULATION REMARKS
Capacity
10MB QPSK 16QAM PDH E1 LAN
20MB QPSK 16QAM PDH E1 LAN
40MB QPSK 16QAM PDH E1/E3 LAN
80MB 16QAM PDH E1/E3 LAN
100MB 32QAM PDH LAN
156MB 128QAM SDH STM-1 LAN
2 X 156MB 128QAM SDH 2 X STM-1 LAN

TOPC-E4010E-01-07371 PASOLINK NEO 47


INDICATORS - MODEM

POWER (GREEN)
DC POWER ON

TX STATUS (Green) ODU (RED)


TX STATUS OF (1+1) TX RF POWER LOW ALM
RX RF LEVEL LOW ALM
INPUT IF LOW ALM (From IDU)
APC ALM
IF CABLE OPEN (BLINKS)
RX STATUS (Green)
RX STATUS OF (1+1) ODU MIS-MATCH

XPIC RESET MD/CBL (RED)


XPIC FUNCTION OFF
MOD ALM
DEM ALM
HBER ALM
LOW BER ALM
IF CABLE SHORT (BLINKS)
Loss of Radio Frame Sync

TOPC-E4010E-01-07371 PASOLINK NEO 48


MODEM – CONNECTORS & SWITCHES

XIF IN/ OUT SELV (DC IN) 4 Pin


Frequency: 140 MHz 1 Ground
REF FREQ: 5 MHz 2 -48 V (-40.5 to -57)
Connector: IEC 169-29(1.0/2.3) 3 Ground
Impedance: 75 Ohms 4 -48 V (-40.5 to -57)
FOR XPIC BETWEEN IDUs Molex M5569-04A1
Connector
GROUND TERMINAL
FRAME GROUND

XPIC CONTROL( D-SUB 15 PIN Female) POWER


IF IN / OUT
1 XPIC SV TXD(+) 9 XPIC SEL IN(-) ON / OFF SWITCH
TX frequency: 340 MHz
2 XPIC SC RXD(+) 10 XPIC SEL OUT(-)
RX Frequency: 140 MHz
3 Ground 11 Ground
DC Power : -48V
4 XPIC SEL IN(+) 12 XPIC Reset IN(-)
Connector: TNC (Female)
5 XPIC SEL OUT(+) 13 XPIC Reset out (-)
Impedance: 50 Ohms
6 XPIC SV TXD(-) 14 XPIC Reset Out(+)
7 XPIC SV RXD(-) 15 Ground
8 XPIC Reset IN (+)
FOR XPIC BETWEEN IDUs

TOPC-E4010E-01-07371 PASOLINK NEO 49


16E1 & 2PORT LAN INTFC FOR PDH
48E1 INTFC FOR PDH
2X E3 & 3 PORT LAN INTFC FOR PDH
4 PORT LAN INTFC FOR PDH

TOPC-E4010E-01-07371 PASOLINK NEO 50


PDH INTFC – 16E1 & 2PORT LAN
E1 INTFC

Input / Output signal Up to 16 E1s


PDH
Bit Rate 2.048Mpps +/_ 50ppm E1 x 16 Channels (D-Sub(37pin) x 2,
Impedance 75 Ohms, Unbalance
(S/W Selectable) 120 Ohms Balance 75/120 ohm (S/W selectable)
Connector 2 x D-Sub (37 pin)

10/100BASE-T(X) x 2 Ports (RJ-45 x 2),


Auto-Negotiation / Auto-MDI/MDIX

LAN INTFC (2 ports)

Input / Output 10/100 Base-T(X)


signal

Flow Control Full Duplex or Half


Duplex

Forwarding Mode Store and Forwarding

Connector 2 x RJ-45

Transmission Shared with E1


Rate Channels

Transmission Capacity QPSK 16 QAM 32 QAM 128 QAM


10MB
20MB QPSK
16QAM
40MB
N/A N/A
80MB
100MB N/A
N/A
156MB

TOPC-E4010E-01-07371 PASOLINK NEO 51


PDH INTFC – 48E1

PDH

E1 INTFC E1 x 48 Channels (MDR(68pin) x 3


Input / Output signal Up to 48 E1s

Bit Rate 2.048Mpps +/_ 50ppm 75/120 ohm S/W selectable)


Impedance 75 Ohms, Unbalance
(S/W Selectable) 120 Ohms Balance LAN function is not available.
Connector 3 x MDR (68 pin)

Transmission
QPSK 16 QAM 32 QAM 128 QAM
Capacity
10MB
20MB QPSK
16QAM
40MB
N/A
80MB
100MB 32QAM
156MB

TOPC-E4010E-01-07371 PASOLINK NEO 52


PDH INTFC – 2E3 / WS / 2PORT LAN
TOTAL CAPACITY

E3 Capacity Wayside/ LAN Capacity SC LAN Capacity


2 CHANNEL E3 INTERFACE PDH
2 Channels 8x E1 Channels 64 Kbps to 256
Input / Output signal (main) One or two E3 signals Kbps
Bit Rate 34.368 Mbps +/_20ppm
Transmission Capacity QPSK 16 QAM 32 QAM 128 QAM
Impedance 75 Ohms, Unbalance
10MB
Connector IEC 169-29 (1.0/2.3) 20MB
40MB QPSK
16QAM N/A N/A
WAYSIDE(WS) E1 INTFC 80MB
Input / Output signal Up to 8 E1s 100MB

Bit Rate 2.048Mpps +/_ 50ppm 156MB

Impedance 75 Ohms, Unbalance


(S/W Selectable) 120 Ohms Balance

Connector D-Sub 37 pins

Remarks 1 x E3: 4 x E1 wayside CH

2 x E3:8 x E1 wayside CH

2 Port LAN INTFC

Input/Output signal 10/100 Base-T(X)

Auto Sensing or Fixed E3 x 1/2 Channels (IEC-Mini, 75 ohm)


Flow Control Full duplex or half duplex
WS(E1) x 4/8 Channels (D-Sub(37pin),
Forwarding Mode Store and Forwarding

Share Wayside 2 to 8 Mbps (1 x E2)


75/120 ohm (S/W selectable)
2 to 16 Mbps (2 x E3)

SC1 to SC4 64Kbps, 128Kbps, 256Kbps 10/100BASE-T(X) x 2 Ports (RJ-45 x 2),


Connector 2 X RJ 45

TOPC-E4010E-01-07371 PASOLINK NEO 53


PDH INTFC –4PORT LAN & E1

E1 INTFC PDH
Input / Output signal Up to 8 E1s E1 x 4/8 Channels (D-Sub(37pin)
Bit Rate 2.048Mpps +/_ 50ppm
75/120 ohm (S/W selectable)
Impedance 75 Ohms, Unbalance
(S/W Selectable) 120 Ohms Balance
10/100BASE-T(X) x 4 Ports (RJ-45 x 4)
Connector D-Sub 37 pins
Auto-Negotiation / Auto-MDI/MDIX)
4 Port LAN INTFC

Input/Output signal 10/100 Base-T(X)

Auto Sensing or Fixed

Flow Control Full duplex or half duplex

Forwarding Mode Store and Forwarding

Connector 4 X RJ 45

Transmission
QPSK 16 QAM 32 QAM 128 QAM
Capacity
10MB 5E1 LAN NOT SUPPORTED
20MB LAN & 8E1 SHARED (4M TO 20M)
40MB LAN & 8E1 SHARED (24M TO 40M N/A
LAN & 8E1 SHARED N/A
80MB N/A
(64M TO 80M)
100MB N/A LAN & 4E1 FIXED
156MB N/A

TOPC-E4010E-01-07371 PASOLINK NEO 54


INDICATORS – PDH INTFC
LAN link established/Blink when packets are transferred (Green)
16 E1 & 2-PORT LAN INTFC PDH
Duplex mode lights / Flash when in Collision (Amber)

LAN signal is in 100BASE-TX Mode (Green)

•Loss of Signal from MUX


•Loss of Output signal to MUX is detected
•Channel Usage Error
•Module Mismatch
•LAN Link failure
48 E1 INTFC •AIS Send
•AIS Received

•Loss of Signal from MUX


•Loss of Output signal to MUX is detected
•Channel Usage Error
•Module Mismatch
•AIS Send
•AIS Received

TOPC-E4010E-01-07371 PASOLINK NEO 55


INDICATORS – 2E3 / WS / 2PORT LAN
LAN link established/Blink when packets are transferred (Green)

Duplex mode lights / Flash when in Collision (Amber)


PDH
LAN signal is in 100BASE-TX Mode (Green)

•Loss of Signal (E3 & WS) from MUX


•Loss of Output signal to MUX is detected
•Channel Usage Error
•Module Mismatch
LAN link established/Blink when packets are transferred (Green)
•LAN Link failure
Duplex mode lights / Flash when in Collision (Amber)
•AIS Send
•AIS Received
LAN signal is in 100BASE-TX Mode (Green) •Module Failure

•Loss of signal(E1) from MUX


•Loss of output signal to MUX detected
•Channel Usage Error
•LAN link failure
•Module mismatch error

TOPC-E4010E-01-07371 PASOLINK NEO 56


16E1 & 2PORT LAN - Connectors

19 1

37 20

2M IN / OUT-A D-SUB (37 PIN) 2M IN / OUT-B D-SUB (37 PIN) LAN PORTS 1 & 2 (RJ-45 8-Pin)
CH 8 - INPUT (+) 1 20 CH 8 - OUTPUT (+) CH 16 - INPUT (+) 1 20 CH 16 - OUTPUT (+)
CH 8 - INPUT (-) 2 21 CH 8 - OUTPUT (-) CH 16 - INPUT (-) 2 21 CH 16 - OUTPUT (-) 1 LAN TD+ (LAN RD+)
CH 7 - INPUT (+) 3 22 CH 7 - OUTPUT (+) CH 15 - INPUT (+) 3 22 CH 15 - OUTPUT (+) 2 LAN TD –(LAN ED-)
CH 7 - INPUT (-) 4 23 CH 7 - OUTPUT (-) CH 15 - INPUT (-) 4 23 CH 15 - OUTPUT (-) 3 LAN RD+ (LAN TD+)
GROUND 5 24 GROUND GROUND 5 24 GROUND 4 Not Connected
CH 6 - INPUT (+) 6 25 CH 6 - OUTPUT (+) CH 14 - INPUT (+) 6 25 CH 14 - OUTPUT (+)
5 Not Connected
CH 6 - INPUT (-) 7 26 CH 6 - OUTPUT (-) CH 14 - INPUT (-) 7 26 CH 14 - OUTPUT (-)
CH 5 - INPUT (+) 8 27 CH 5 - OUTPUT (+) CH 13 - INPUT (+) 8 27 CH 13 - OUTPUT (+) 6 LAN RD- (LAN TD -)
CH 5 - INPUT (-) 9 28 CH 5 - OUTPUT (-) CH 13 - INPUT (-) 9 28 CH 13 - OUTPUT (-) 7 Not Connected
GROUND 10 29 CH 4 - OUTPUT (+) GROUND 10 29 CH 12 - OUTPUT (+) 8 Not Connected
CH 4 - INPUT (+) 11 30 CH 4 - OUTPUT (-) CH 12 - INPUT (+) 11 30 CH 12 - OUTPUT (-)
CH 4 - INPUT (-) 12 31 CH 3 - OUTPUT (+) CH 12 - INPUT (-) 12 31 CH 11 - OUTPUT (+) Do not connected any cable to the
CH 3 - INPUT (+) 13 32 CH 3 - OUTPUT (-) CH 11 - INPUT (+) 13 32 CH 11 - OUTPUT (-) “not connected” pins
CH 3 - INPUT (-) 14 33 GROUND CH 11 - INPUT (-) 14 33 GROUND
GROUND 15 34 CH 2 - OUTPUT (+) GROUND 15 34 CH 10 - OUTPUT (+)
CH 2 - INPUT (+) 16 35 CH 2 - OUTPUT (-) CH 10 - INPUT (+) 16 35 CH 10 - OUTPUT (-)
CH 2 - INPUT (-) 17 36 CH 1 - OUTPUT (+) CH 10 - INPUT (-) 17 36 CH 9 - OUTPUT (+)
CH 1 - INPUT (+) 18 37 CH 1 - OUTPUT (-) CH 9- INPUT (+) 18 37 CH 9 - OUTPUT (-)
CH 1 - INPUT (-) 19 CH 9 - INPUT (-) 19

TOPC-E4010E-01-07371 PASOLINK NEO 57


48E1 INTFC - Connectors

34 1

68 35

2M IN / OUT-A MDR (68 PIN) 2M IN / OUT-B


OUT-A MDR (68 PIN) 2M IN / OUT-C
OUT-A MDR (68 PIN)
Ground 1 35 Ground Ground 1 35 Ground Ground 1 35 Ground
CH 16 - INPUT (+) 2 36 CH 16 - INPUT (-) CH 32
16 - INPUT (+) 2 36 CH 32
16 - INPUT (-) CH 48
16 - INPUT (+) 2 36 CH 48
16 - INPUT (-)
CH 16 - OUTPUT (+) 3 37 CH 16 - OUTPUT (-) CH 32
16 - OUTPUT (+) 3 37 CH 32
16 - OUTPUT (-) CH 48
16 - OUTPUT (+) 3 37 CH 48
16 - OUTPUT (-)
CH 15 - INPUT (+) 4 38 CH 15 - INPUT (-) CH 31
15 - INPUT (+) 4 38 CH 31
15 - INPUT (-) CH 47
15 - INPUT (+) 4 38 CH 47
15 - INPUT (-)
CH 15 - OUTPUT (+) 5 39 CH 15 - OUTPUT (-) CH 31
15 - OUTPUT (+) 5 39 CH 31
15 - OUTPUT (-) CH 47
15 - OUTPUT (+) 5 39 CH 47
15 - OUTPUT (-)
CH 14- INPUT (+) 6 40 CH 14 - INPUT (-) CH 30-
14- INPUT (+) 6 40 CH 30
14 - INPUT (-) CH 46-
14- INPUT (+) 6 40 CH 46
14 - INPUT (-)
CH 14- OUTPUT (+) 7 41 CH 14 - OUTPUT (-) CH 30- OUTPUT (+) 7 41 CH 30
14 - OUTPUT (-) CH 46- OUTPUT (+) 7 41 CH 46
14 - OUTPUT (-)
CH 13 - INPUT (+) 8 42 CH 13 - INPUT (-) CH 29
13 - INPUT (+) 8 42 CH 29
13 - INPUT (-) CH 45
13 - INPUT (+) 8 42 CH 45
13 - INPUT (-)
CH 13- OUTPUT (+) 9 43 CH 13- OUTPUT (-) CH 29-
13- OUTPUT (+) 9 43 CH 13-- OUTPUT (-)
CH29 CH 45-
13- OUTPUT (+) 9 43 CH 13-- OUTPUT (-)
CH45
CH 12 - INPUT (+) 10 44 CH 12 - INPUT (-) CH 28
12 - INPUT (+) 10 44 CH 28
12 - INPUT (-) CH 44
12 - INPUT (+) 10 44 CH 44
12 - INPUT (-)
CH 12 - OUTPUT (+) 11 45 CH 12 - OUTPUT (-) CH 28
12 - OUTPUT (+) 11 45 CH 28
12 - OUTPUT (-) CH 44
12 - OUTPUT (+) 11 45 CH 44
12 - OUTPUT (-)
CH 11 - INPUT (+) 12 46 CH 11- INPUT (-) CH 27
11 - INPUT (+) 12 46 CH 27-
11- INPUT (-) CH 43
11 - INPUT (+) 12 46 CH 11-
437-INPUT
INPUT(-)(-)
CH 11 - OUTPUT (+) 13 47 CH 11- OUTPUT (-) CH 27
11 - OUTPUT (+) 13 47 CH 27-
11- OUTPUT (-) CH 43
11 - OUTPUT (+) 13 47 CH 43-
11- OUTPUT (-)
CH 10- INPUT (+) 14 48 CH 10 - INPUT (-) CH 26-
10- INPUT (+) 14 48 CH 26
10 - INPUT (-) CH 42-
10- INPUT (+) 14 48 CH 42
10 - INPUT (-)
CH 10- OUTPUT (+) 15 49 CH 10- OUTPUT (-) CH 26-
10- OUTPUT (+) 15 49 CH 26-
10- OUTPUT (-) CH 42-
10- OUTPUT (+) 15 49 CH 42-
10- OUTPUT (-)
CH 9 - INPUT (+) 16 50 CH 9 - INPUT (-) CH 9
25- -INPUT
INPUT(+)
(+) 16 50 CH 9
25- -INPUT
INPUT(-)(-) CH 9
41- -INPUT
INPUT(+)
(+) 16 50 CH 41
9 - -INPUT
INPUT(-)(-)
CH 9- OUTPUT (+) 17 51 CH 9- OUTPUT (-) CH 9-
25-OUTPUT
OUTPUT(+) (+) 17 51 CH 9-
25-OUTPUT
OUTPUT(-)(-) CH 9-
41-OUTPUT
OUTPUT(+) (+) 17 51 CH 9-
41-OUTPUT
OUTPUT(-)(-)
CH 8 - INPUT (+) 18 52 CH 8 - INPUT (-) CH 8
24- -INPUT
INPUT(+)
(+) 18 52 CH 8
24- -INPUT
INPUT(-)(-) CH 8
40- -INPUT
INPUT(+)
(+) 18 52 CH 40
8 - -INPUT
INPUT(-)(-)
CH 8 - OUTPUT (+) 19 53 CH 8 - OUTPUT (-) CH 8
24- -OUTPUT
OUTPUT(+) (+) 19 53 CH 8
24- -OUTPUT
OUTPUT(-)(-) CH 8
40- -OUTPUT
OUTPUT(+) (+) 19 53 CH 8
40- -OUTPUT
OUTPUT(-)(-)
CH 7 - INPUT (+) 20 54 CH 7 - INPUT (-) CH 7
23- -INPUT
INPUT(+)
(+) 20 54 CH 7
23- -INPUT
INPUT(-)(-) CH 7
39- -INPUT
INPUT(+)
(+) 20 54 CH 39
7 - -INPUT
INPUT(-)(-)
CH 7 - OUTPUT (+) 21 55 CH 7 - OUTPUT (-) CH 7
23- -OUTPUT
OUTPUT(+) (+) 21 55 CH 7
23- -OUTPUT
OUTPUT(-)(-) CH 7
39- -OUTPUT
OUTPUT(+) (+) 21 55 CH 7
39- -OUTPUT
OUTPUT(-)(-)
CH 6- INPUT (+) 22 56 CH 6 - INPUT (-) CH 6-
22-INPUT
INPUT(+)
(+) 22 56 CH 6
22- -INPUT
INPUT(-)(-) CH 6-
38-INPUT
INPUT(+)
(+) 22 56 CH 38
6 - -INPUT
INPUT(-)(-)
CH 6- OUTPUT (+) 23 57 CH 6 - OUTPUT (-) CH 6-
22-OUTPUT
OUTPUT(+) (+) 23 57 CH 6
22- -OUTPUT
OUTPUT(-)(-) CH 6-
38-OUTPUT
OUTPUT(+) (+) 23 57 CH 6
38- -OUTPUT
OUTPUT(-)(-)
CH 5 - INPUT (+) 24 58 CH 5 - INPUT (-) CH 5
21- -INPUT
INPUT(+)
(+) 24 58 CH 5
21- -INPUT
INPUT(-)(-) CH 5
37- -INPUT
INPUT(+)
(+) 24 58 CH 37
5 - -INPUT
INPUT(-)(-)
CH 5- OUTPUT (+) 25 59 CH 5- OUTPUT (-) CH 5-
21-OUTPUT
OUTPUT(+) (+) 25 59 CH 5-
21-OUTPUT
OUTPUT(-)(-) CH 5-
37-OUTPUT
OUTPUT(+) (+) 25 59 CH 5-
37-OUTPUT
OUTPUT(-)(-)
CH 4 - INPUT (+) 26 60 CH 4 - INPUT (-) CH 4
20- -INPUT
INPUT(+)
(+) 26 60 CH 4
20- -INPUT
INPUT(-)(-) CH 4
36- -INPUT
INPUT(+)
(+) 26 60 CH 36
4 - -INPUT
INPUT(-)(-)
CH 4- OUTPUT (+) 27 61 CH 4 - OUTPUT (-) CH 4-
20-OUTPUT
OUTPUT(+) (+) 27 61 CH 4
20- -OUTPUT
OUTPUT(-)(-) CH 4-
36-OUTPUT
OUTPUT(+) (+) 27 61 CH 4
36- -OUTPUT
OUTPUT(-)(-)
CH 3 - INPUT (+) 28 62 CH 3- INPUT (-) CH 3
19- -INPUT
INPUT(+)
(+) 28 62 CH 3-
19-INPUT
INPUT(-)(-) CH 3
35- -INPUT
INPUT(+)
(+) 28 62 CH 35-
3- INPUT
INPUT(-)(-)
CH 3 - OUTPUT (+) 29 63 CH 3- OUTPUT (-) CH 3
19- -OUTPUT
OUTPUT(+) (+) 29 63 CH 19-
3- OUTPUT
OUTPUT(-)(-) CH 3
35- -OUTPUT
OUTPUT(+) (+) 29 63 CH 3-
35-OUTPUT
OUTPUT(-)(-)
CH 2- INPUT (+) 30 64 CH 2 - INPUT (-) CH 2-
18-INPUT
INPUT(+)
(+) 30 64 CH 18
2 - -INPUT
INPUT(-)(-) CH 2-
34-INPUT
INPUT(+)
(+) 30 64 CH 34
2 - -INPUT
INPUT(-)(-)
CH 2- OUTPUT (+) 31 65 CH 2- OUTPUT (-) CH 2-
18-OUTPUT
OUTPUT(+) (+) 31 65 CH 18-
2- OUTPUT
OUTPUT(-)(-) CH 2-
34-OUTPUT
OUTPUT(+) (+) 31 65 CH 2-
34-OUTPUT
OUTPUT(-)(-)
CH 1 - INPUT (+) 32 66 CH 1 - INPUT (-) CH 1
17- -INPUT
INPUT(+)
(+) 32 66 CH 17
1 - -INPUT
INPUT(-)(-) CH 1
33- -INPUT
INPUT(+)
(+) 32 66 CH 33
1 - -INPUT
INPUT(-)(-)
CH 1- OUTPUT (+) 33 67 CH 1- OUTPUT (-) CH 1-
17-OUTPUT
OUTPUT(+) (+) 33 67 CH 17-
1- OUTPUT
OUTPUT(-)(-) CH 1-
33-OUTPUT
OUTPUT(+) (+) 33 67 CH 1-
33-OUTPUT
OUTPUT(-)(-)
Ground 34 68 Ground Ground 34 68 Ground Ground 34 68 Ground

TOPC-E4010E-01-07371 PASOLINK NEO 58


2E3 / WS / 2PORT LAN- CONNECTORS

PDH

19 1

37 20

WS IN /OUT D-SUB (37 PIN) LAN PORTS 1 & 2 (RJ-45 8-Pin)


E3 CH#
CH-8 INPUT (+) 1 20 CH-8 OUTPUT (+)
IN IEC 169-29 (1.0/2.3) 1 LAN TD+ (LAN RD+)
CH-8 INPUT (-) 2 21 CH-8 OUTPUT (-)
OUT IEC 169-29 (1.0/2.3) CH-7 INPUT (+) 3 22 CH-7 OUTPUT (+) 2 LAN TD –(LAN RD-)
CH-7 INPUT (-) 4 23 CH-7 OUTPUT (-) 3 LAN RD+ (LAN TD+)
GROUND 5 24 GROUND
4 Not Connected
CH-6 INPUT (+) 6 25 CH-6 OUTPUT (+)
CH-6 INPUT (-) 7 26 CH-6 OUTPUT (-) 5 Not Connected
CH-5 INPUT (+) 8 27 CH-5 OUTPUT (+) 6 LAN RD- (LAN TD -)
CH-5 INPUT (-) 9 28 CH-5 OUTPUT (-)
7 Not Connected
GROUND 10 29 CH-4 OUTPUT (+)
CH-4 INPUT (+) 11 30 CH-4 OUTPUT (-) 8 Not Connected
CH-4 INPUT (-) 12 31 CH-3 OUTPUT (+) Do not connected any cable to the
CH-5 INPUT (+) 13 32 CH-3 OUTPUT (-) “not connected” pins
CH-3 INPUT (-) 14 33 GROUND
GROUND 15 34 CH-2 OUTPUT (+)
CH-2INPUT (+) 16 35 CH-2 OUTPUT (-)
CH-2INPUT (-) 17 36 CH-1 OUTPUT (+)
CH-1INPUT (+) 18 37 CH-1 OUTPUT (-)
CH-1 INPUT (-) 19

TOPC-E4010E-01-07371 PASOLINK NEO 59


4PORT LAN & E1 - CONNECTORS

PDH

19 1

37 20

E1 IN /OUT D-SUB (37 PIN)


CH-8 INPUT (+) 1 20 CH-8 OUTPUT (+) LAN PORTS (1 to 4) (RJ-45 8-Pin)
CH-8 INPUT (-) 2 21 CH-8 OUTPUT (-)
1 LAN TD+ (LAN RD+)
CH-7 INPUT (+) 3 22 CH-7 OUTPUT (+) 2 LAN TD –(LAN RD-)
CH-7 INPUT (-) 4 23 CH-7 OUTPUT (-)
3 LAN RD+ (LAN TD+)
GROUND 5 24 GROUND 4 Not Connected
CH-6 INPUT (+) 6 25 CH-6 OUTPUT (+)
5 Not Connected
CH-6 INPUT (-) 7 26 CH-6 OUTPUT (-) 6 LAN RD- (LAN TD -)
CH-5 INPUT (+) 8 27 CH-5 OUTPUT (+)
7 Not Connected
CH-5 INPUT (-) 9 28 CH-5 OUTPUT (-) 8 Not Connected
GROUND 10 29 CH-4 OUTPUT (+) Do not connected any cable to the
CH-4 INPUT (+) 11 30 CH-4 OUTPUT (-) “not connected” pins

CH-4 INPUT (-) 12 31 CH-3 OUTPUT (+)


CH-5 INPUT (+) 13 32 CH-3 OUTPUT (-)
CH-3 INPUT (-) 14 33 GROUND
GROUND 15 34 CH-2 OUTPUT (+)
CH-2INPUT (+) 16 35 CH-2 OUTPUT (-)
CH-2INPUT (-) 17 36 CH-1 OUTPUT (+)
CH-1INPUT (+) 18 37 CH-1 OUTPUT (-)
CH-1 INPUT (-) 19

TOPC-E4010E-01-07371 PASOLINK NEO 60


STM-1 ELECTRICAL FOR SDH
STM-1 OPTICAL FOR SDH
STM-1 2 PORT LAN FOR SDH
WS/ SC LAN FOR SDH
GBIT ETHER FOR SDH

TOPC-E4010E-01-07371 PASOLINK NEO 61


INTERFACE - SDH
STM-1 INTFC (ELECTRICAL) -SPECIFICATIONS SDH
TYPE G.703
BITRATE 155.520 Mbps
STM-1 ELECTRICAL INTFC
LEVEL 1 Vp_p RSOH TERMINATION
CODE CMI
STUFFING CONTROL
CONNECTOR IEC 169-29 (1.0/2.3)
IMPEDANCE 75 Ohms (Unbalanced) RX HITLESS SWITCHING FOR (1+1) PROTECTION CONFIGURATION

MAIN SLOT SUB (PROT) SLOT

STM-1 INTFC (OPTICAL) -SPECIFICATIONS


TYPE G957 STM-1 OPTICAL INTFC
BITRATE 155.520 Mbps

LEVEL
L-1.1: 0 TO -8dBm (TX) / -10 TO -34 dBm (RX) AUTOMATIC LASER SHUTDOWN (OPTICAL)
S-1.1: -8 TO -15dBm (TX) / -8 TO -28 dBm (RX)
CODE NRZ
AUTOMATIC PROTECTION SWITCHING (OPTICAL)
WAVELENGTH 1310 NM
CONNECTOR LC Transmission
QPSK 16 QAM 32 QAM 128 QAM
Capacity
10MB N/A
20MB N/A
40MB N/A N/A
80MB N/A
100MB N/A
156MB N/A 128QAM

TOPC-E4010E-01-07371 PASOLINK NEO 62


SDH INTFC – INDICATORS
SDH
MAIN SLOT SUB (PROT) SLOT

•Loss of STM-1 from MUX


•Loss of Frame of STM-1 signal from MUX or DMR
•E-BER from MUX or DMR
•SD from MUX or DMR
•Module Failure
•Module Mismatch

LIGHTS GREEN W/O APS


LIGHTS GREEN when Online with APS
LIGHTS GREEN when Online with APS

TOPC-E4010E-01-07371 PASOLINK NEO 63


SDH INTFC – OPTICAL
TWO STM-1 INTFC : ELECTRICAL AND OPTICAL SDH
RSOH TERMINATION
STUFFING CONTROL
RX HITLESS SWITCHING FOR (1+1) PROTECTION CONFIGURATION
PERFORMANCE MONITOR (G.826/G.828)
AUTOMATIC PROTECTION SWITCHING (OPTICAL)
AUTOMATIC LASER SHUTDOWN (OPTICAL)
CHANGE THE SFP MODULE FOR L-1.1 / S-1.1 LED OFF when standby with APS

LIGHTS GREEN W/O APS


WITHOUT APS
WITH APS
LIGHTS GREEN when Online with APS

Transmission STM-1 INTFC (OPTICAL) -SPECIFICATIONS


QPSK 16 QAM 32 QAM 128 QAM
Capacity
TYPE G957
10MB N/A BITRATE 155.520 Mbps
20MB N/A L-1.1: 0 TO -8dBm (TX) / -10 TO -34 dBm (RX)
LEVEL
40MB N/A N/A S-1.1: -8 TO -15dBm (TX) / -8 TO -28 dBm (RX)
80MB N/A CODE NRZ

100MB N/A WAVELENGTH 1310 NM

156MB N/A 128QAM CONNECTOR LC

TOPC-E4010E-01-07371 PASOLINK NEO 64


GIGABIT ETHER - INTERFACE
GIGABIT ETHER INTERFACE ELECTRICAL OR OPTICAL SDH
LAN SIGNAL IS ENCAPSULATED IN STM-1 SIGNAL
RSOH BYTES AVAILABLE BETWEEN RADIO STATIONS
RMON AVAILABLE FOR LINE SIDE NOT RADIO SIDE
MAX PACKET SIZE 9600 BYTES
LAN /WS INTFC IN SUB SLOT
MAIN SLOT SUB (PROT) SLOT
OPT

Gigabit Ether Interface (Optical) Gigabit Ether Interface (Electrical)

Input / Output signal 1000 BASE-SX Input / Output signal 1000 BASE-SX

Speed & Duplex 1000 Mbits Full Duplex Speed & Duplex 1000 Mbits Full Duplex
Auto Negotiation fixed Auto Negotiation fixed

Flow Control ON or OFF (Selectable) Flow Control ON or OFF (Selectable)

Link Loss Forwarding Disable/Enable (Selectable) Link Loss Forwarding Disable/Enable (Selectable)

Connector SFP Optical Interface Transmission 16 32 Connector RJ-45


QPSK 128 QAM
Capacity QAM QAM
Transmission Rate 150 Mbps Transmission Rate 150 Mbps
10MB N/A
20MB N/A
40MB N/A N/A
80MB N/A
100MB N/A
156MB N/A 128QAM

TOPC-E4010E-01-07371 PASOLINK NEO 65


GIGABIT ETHER - INTERFACE
ALARM SDH
MODULE MISMATCH
MODULE FAILURE
LOS FROM DMR
LOF FROM DMR
EXCESSIVE BER FROM DMR
SD FROM DMR
GbE OPTICAL OUTPUT
INTERRUPTED
LAN LINK FAILURE

MAIN SLOT SUB (PROT) SLOT

LAN PORTS (1 to 4) (RJ-45 8-Pin)


Gigabit Ether Interface (Optical) 1 DATA-A(+) / DATA-B (+)

Input (Right) 1000 BASE-SX Input 2 DATA-A (-) / DATA-B (-)


3 DATA-B(+) / DATA-A (+)
Output (Left) 1000 BASE-SX Output
4 DATA-C (+) / DATA-D (+)
5 DATA-C(-) / DATA-D (-)
6 DATA-B (-) / DATA-A (+)
7 DATA-D(+) / DATA-C (+)
8 DATA-D (-) / DATA-C (-)
Do not connected any cable to the “not
connected” pins

TOPC-E4010E-01-07371 PASOLINK NEO 66


SDH INTFC – INDICATORS

SDH
STM-1 INTFC (ELECTRICAL) -
SPECIFICATIONS
TYPE G.703
BITRATE 155.520 Mbps
LEVEL 1 Vp_p
CODE CMI
CONNECTOR IEC 169-29 (1.0/2.3)
IMPEDANCE 75 Ohms (Unbalanced)

MAIN SLOT SUB (PROT) SLOT

ALARM
MODULE MISMATCH
MODULE FAILURE
LOS FROM DMR
LOF FROM DMR
EXCESSIVE BER FROM DMR
SD FROM DMR
GbE OPTICAL OUTPUT INTERRUPTED
LAN LINK FAILURE

TOPC-E4010E-01-07371 PASOLINK NEO 67


SDH INTFC – 2 PORT LAN
(Installed in Main slot)
TWO LAN PORTS 10/100 BASE – Tx SDH
LAN SIGNAL IS ENCAPSULATED IN STM-1 SIGNAL
LAN SIGNAL IS USED IN 2-PORT SHARED MODE
WS CHANNEL NOT USED

MAIN SLOT SUB (PROT) SLOT

M.S

TYPE - C

LAN PORTS (1 to 4) (RJ-45 8-Pin) 2 Port LAN INTFC


1 LAN TD+ (LAN RD+) LAN PORT 1 & 2 SEPARATED MODE
2 LAN TD –(LAN RD-)
Input/Output signal 10/100 Base-T(X)
3 LAN RD+ (LAN TD+)
Auto Sensing or Fixed
4 Not Connected
5 Not Connected Flow Control Full duplex or half duplex

6 LAN RD- (LAN TD -) Forwarding Mode Store and Forwarding


7 Not Connected Connector 2 X RJ 45
8 Not Connected
Port 1& 2 75 Mbps + 75 Mbps
Do not connected any cable to the 100 Mbps + 50 Mbps
“not connected” pins
Best effort + Best effort

TOPC-E4010E-01-07371 PASOLINK NEO 68


SDH INTFC – INDICATORS
(Installed in Sub slot)
TWO LAN PORTS 10/100 BASE – Tx USED AS SC LAN SDH
2.O48 Mbps WAY SIDE SIGNAL
75 /120 ohm (S/W SELECTABLE)

Type -B

Type -A

MAIN SLOT SUB (PROT) SLOT

E1 WS INTFC 2 Port LAN INTFC

Input / Output signal One E1 LAN PORT 1 & 2 SHARED MODE

Bit Rate 2.048Mpps +/_ 50ppm Input/Output signal 10/100 Base-T(X)

Impedance 75 Ohms, Unbalance Auto Sensing or Fixed


(S/W Selectable) 120 Ohms Balance Flow Control Full duplex or half duplex
Connector D-Sub 37 pins Forwarding Mode Store and Forwarding

Connector 2 X RJ 45

Transmission Rate 64/128/256 Kbps (RFCOH)


2.048 Mbps (WS not used)

TOPC-E4010E-01-07371 PASOLINK NEO 69


SDH INTFC – INDICATORS

SDH

MAIN SLOT SUB (PROT) SLOT

LAN PORTS (1 to 2) (RJ-45 8-Pin)

1 LAN TD+ (LAN RD+)

2 LAN TD –(LAN RD-)

3 LAN RD+ (LAN TD+) WS IN /OUT D-SUB (37 PIN)


WS CH INPUT (+) 1 6 WS CH INPUT (-)
4 Not Connected
GROUND 2 7 GROUND
5 Not Connected
WS CH OUTPUT (+) 3 8 WS CH OUTPUT (-)
6 LAN RD- (LAN TD -) GROUND 4 9 GROUND
7 Not Connected GROUND 5

8 Not Connected

Do not connected any cable to the


“not connected” pins

TOPC-E4010E-01-07371 PASOLINK NEO 70


SDH INTFC – INDICATORS

SDH

SUB (PROT) SLOT

MAIN SLOT

LAN signal is in 100BASE-TX Mode (Green)

Duplex mode lights / Flash when in Collision (Amber)

LAN link established/Blink when packets are transferred (Green)

Lights when wayside channel is used


ALARM
Loss of signal (LOS) from DTE
Module Mismatch
LAN Link Failure
Module Failure
WS AIS Received / send

TOPC-E4010E-01-07371 PASOLINK NEO 71


OUT DOOR UNIT

TOPC-E4010E-01-07371 PASOLINK NEO 72


OUT DOOR UNIT

UP CONV RF AMP

LO
TX RF
BPF
MPX
DOWN CONV

RX RF
LNA BPF

CONTROL

DC-DC CONV

TOPC-E4010E-01-07371 PASOLINK NEO 73


OUT DOOR UNIT (6-52 GHz)

RF IN/OUT COAXIAL TYPE (6-8 GHz) RF IN/OUT WG TYPE (6-8 GHz)

RX LEV MONITOR
IF IN/OUT

Turn OFF the IDU DC


Turn OFF the IDU DC
power before removing RF IN/OUT 10 – 52 GHz
power before removing
the IF cable
the IF cable Frame Ground ANTENNA DIRECT MOUNT TYPE

TOPC-E4010E-01-07371 PASOLINK NEO 74


ODU OUT LINE
RF IN / OUT
•6/7/8 GHz: N-TYPE (Female) Coaxial interface
•6 GHz: PDR-70
•7/8 GHz: PDR-84
•10/11 GHz: PDR-100
•13 GHz: PBR-120 or PBR-140
•15 GHz:PBR-140
•18-23 GHz: PBR-220
•26 GHz: PBR-260
•28/32/38 GHz: PBR-320

OUT DOOR UNIT - TRP [ ]G – 1B

Module Name RF CKT IF CKT PS

6GHz NWA-009024[ ] H2202[ ]

7GHz NWA-009026[ ] H2203[ ]

8GHz NWA-009028[ ] H2204[ ]

10GHz NWA-009030[ ] H2225[ ]

11GHz NWA-009032[ ] H2205[ ]

13GHz NWA-009034[ ] H2227[ ]

15GHz NWA-009036[ ] H2228[ ]

18GHz NWA-009038[ ] H2229[ ]

23GHz NWA-009040[ ] H2230[ ]

26GHz NWA-009042[ ] H2231[ ]

28GHz NWA-009044[ ] H2232[ ]

32GHz NWA-009046[ ] H2233[ ]

38GHz NWA-009048[ ] H2234[ ]

Layout and arrangement may vary with frequency band 52GHz NWA-009050[ ] H0416[ ]

TOPC-E4010E-01-07371 PASOLINK NEO 75


TYPICAL ODU BLOCK DIAGRAM

IF INPUT ALM TX PWR ALM

APC ALM

RX LEV ALM

Input IF signal consists of:


Each of the input IF signal components are separated in the MULTIPLEXER using
•340 MHz TX IF separation filters. DC voltage is supplied to the DC-DC CONV to produce
•10MHz Control regulated DC voltages required in the ODU.
•DC power -48V The 10 MHz control signal which is ASK modulated is sent to the Control circuit,
Output IF signal consists of: where the ODU controls like TX Power, RF Frequencies etc. are implemented. The
Alarms in ODU are collected in the Control module and sent to the IDU using the
•140 MHz RX IF ASK modulated 10 MHz signal.
•10MHz Alarm/Response

TOPC-E4010E-01-07371 PASOLINK NEO 76


PASOLINK CONNECTORS

DC 10MHz Control RX 140 MHz TX 340 MHz


ASK

TOPC-E4010E-01-07371 PASOLINK NEO 77


TOPC-E4010E-01-07371 PASOLINK NEO 78
Possible Configurations
Single Antenna HS System

MOD ODU-1 ODU-1 MOD


(TX) F 1 M M F1' (TX)
P P
X X
DEM ODU-1 ODU-1 DEM
(RX) F 1 ' F1 F1 (RX)
HL HL
SW
HYB HYB SW
ODU-2 ODU-2
DEM
(RX) F 1 '
F1' (RX)
DEM
M M F1
P P
ODU-2 X X ODU-2
MOD MOD
(TX) F 1 F1' (TX)

Two Antenna HS System

ODU-1 ODU-1
MOD
(TX) F 1 F1 F1' (TX)
MOD
M M
P P
X X
DEM ODU-1 ODU-1 DEM
(RX) F 1 ' F1' F1 (RX)
HL HL
SW SW
ODU-2 ODU-2
DEM DEM
(RX) F 1 ' M M F1 (RX)
P P
ODU-2 X X ODU-2
MOD MOD
(TX) F 1 F1' (TX)

TOPC-E4010E-01-07371 PASOLINK NEO 79


Possible Configurations
Hybrid Diversity System

F1
MOD ODU-1 ODU-1 MOD
(TX) F 1 M M F1' (TX)
P HYB F1' P

DEM ODU-1 X
F2 X
ODU-1 DEM
(RX) F 1 ' F1 (RX)
HL HL
SW SW
ODU-2 ODU-2
DEM DEM
(RX) F 2 ' M M F2 (RX)
P P
ODU-2 X X ODU-2
MOD MOD
(TX) F 2 F2' F2' (TX)

Two Antenna Twin Path System

ODU-1 ODU-1 MOD


MOD (TX)
(TX) F 1 M F1 M
P
F1'

P X
ODU-1 X ODU-1 DEM
DEM
(RX) F 1 ' F1' F1 (RX)
HL HL
SW SW
ODU-2
DEM
ODU-2 F2 F2 (RX)
DEM
(RX) F 1 ' M
M
P
P
X ODU-2
MOD
ODU-2 X
F2' F2' (TX)
MOD
(TX) F 1

TOPC-E4010E-01-07371 PASOLINK NEO 80


Possible Configurations
(2+0) System using OMT

MOD ODU-1 ODU-1 MOD


(TX) F1 M M F1' (TX)
P P
X X
DEM ODU-1 F1 ODU-1 DEM
(RX) F1 ' V V F1 (RX)

OMT F2 F 1' OMT


ODU-2 H H ODU-2
DEM F 2' DEM
(RX) F2 ' M M F2 (RX)
P P
ODU-2 X X ODU-2
MOD MOD
(TX) F2 F2' (TX)

TOPC-E4010E-01-07371 PASOLINK NEO 81


ODU MOUNTING FOR (1+0)
ANTENNA INDIRECT MOUNTING COAXIAL (1+0) ANTENNA INDIRECT MOUNTING WAVEGUIDE (1+0)

6/7/8 GHz

ANTENNA DIRECT MOUNTING (1+0)

TOPC-E4010E-01-07371 PASOLINK NEO 82


ODU MOUNTING FOR 2 (1+0)
ANTENNA DIRECT MOUNTING 2 (1+0)

ANTENNA INDIRECT MOUNTING

ANTENNA INDIRECT MOUNTING COAXIAL 6/7/8 GHz 2 (1+0)

WAVEGUIDE CONNECTION 2 (1+0)

TOPC-E4010E-01-07371 PASOLINK NEO 83


ODU MOUNTING FOR 2(1+1)

ANTENNA INDIRECT MOUNTING


WAVEGUIDE CONNECTION
2(1+1)

TOPC-E4010E-01-07371 PASOLINK NEO 84


ODU MOUNTING FOR (1+1)
ANTENNA INDIRECT MOUNTING ANTENNA INDIRECT MOUNTING
COAXIAL 6/7/8 GHz (1+1) WAVEGUIDE CONNECTION (1+1 SD)

ANTENNA DIRECT MOUNTING (1+1)

6/7/8 GHz
11 – 52 GHz

Loss
11/13/15/18/23 GHz – 3.5 dB
Loss 3.7 dB 26/32/38 GHz – 3.8 dB
52 GHz – 4.5 dB

TOPC-E4010E-01-07371 PASOLINK NEO 85


TOPC-E4010E-01-07371 PASOLINK NEO 86
AUTOMATIC TX POWER CONTROL
Automatic Transmit Power Control Operation
The automatic transmit power control (ATPC) function automatically varies the TX output power
according to path conditions. Fading exerts heavy influences on propagation, causing the receive signal
level at the opposite station to vary. The ATPC function operates by controlling the transmit output
power of the opposite station according to the variation of the received signal level at the local station.
The receive signal level variation at the opposite station is informed to the local station using the ATPC
bits in the overhead. To implement ATPC, the receiving level (RX IN LEV) is detected by the receiver
(RX) and passed on to the CPU in the CTRL circuit of the MODEM module. The CPU then determines
whether the transmit output power needs to be controlled. This is based on the transmit output power,
the minimum and maximum values of the output control range, and the receiving threshold level that
were previously specified using the LCT or PNMT.
The function of the control signal (POWER CONT), is to maintain the RX signal level by lowering or
raising the TX output power of the opposite station. This control signal is based on the result of
comparison between the current receiver input level and the preset receiving threshold level.
Transmission level control can be used not only for setting the same operation (ATPC-ATPC) between
own station and opposite station but also for operation in combination of stations with different
operation (MTPC-ATPC, ATPC-MTPC) between own station and opposite station. The station set in
MTPC mode is not controlled by the information from opposite station but is fixed in its transmitting
output level.
Even if the station is set in the MTPC mode, the opposite station is likely to be set in the ATPC mode.
Therefore setting of the RX Threshold (Receiving threshold level) is required for controlling the
transmission level of the opposite station. Between the stations that are respectively set in the MTPC
mode, however, the setting is disabled.

TOPC-E4010E-01-07371 PASOLINK NEO 87


ATPC Operation

STN - A STN - B Station - A


ATPC TX MAX
ATPC MTPC

TX OUT
RX Threshold = -60dBm

When RSL reaches -60dBm at STN –B STN- ATPC TX MIN


A starts to increase the TX power in 1 dB
steps, this process continues until the ATPC deep shallow
TX MAX level is reached. Any RSL drop
below this point is not compensated. In the
UP Mode ATPC operation starts at -55dBm

RX Level
because of the fixed 5dB hysteresis. Up Mode
-55dBm
The ATPC Control transmits the information

(5dB Fixed)
Hysteresis
on the receiving level to the opposite station
and controls the transmission level of its
own station in accordance with the receiving RX Threshold
(-60dBm)
level of the opposite station. Down Mode
The ATPC Control can be used in several configurations:
Station - B
ATPC - ATPC
MTPC - ATPC Fading depth
deep shallow
ATPC - MTPC

TOPC-E4010E-01-07371 PASOLINK NEO 88


ATPC Operation
Advantages
1. Reduced interference to adjacent/other
systems
Since the transmitted power may be be lower
with ATPC, the amount of interference that may
be introduced to adjacent/other systems will also
be lower. However, adjacent systems that do not
employ ATPC may cause interference to systems
that use ATPC.
2. " Up-fading " characteristic is improved
Since the system normally transmits at a lower
power level, it is more resilient to " UP-fading "
conditions.
3. Residual BER performance is improved
The residual BER performance is improved
because of reduced non-linear distortion since
the amplifier can be operated well within the
linear region at lower transmitter output levels.
4. Increased capacity for star network
configurations
Lower transmitting levels reduces the required
angular discrimination required at the receiving
station. This allows transmission of more RF
channels
TOPC-E4010E-01-07371 PASOLINK NEO 89
SERVICE CHANNELS

Available Service Channels in PASOLINK NEO radio overhead frame

OVERHEAD SERVICE CHANNELS


SC LAN* RSOH (SDH)
SC1 V.11-1 64Kbit/s ( Contra / Co-directional selectable) 100 ohms 64k 128K 256K E1, F1, DCCr

SC2 V.11-2 64Kbit/s( Contra / Co-directional selectable) 100ohms E1, F1, DCCr
SC3 RS-232C-1 9.6 Kbps E1, F1,
SC4 RS-232C-2 9.6 Kbps E1, F1,
SC5 EOW Engineering Order Wire (IDU-IDU), Level: -6 dBm, 600 ohms
NMS 384 kbps
WAYSIDE PDH E3 INTFC Up to 8 E1 Shared with SC LAN
LAN /WS INTFC 1 X E1 ( In Sub Slot) SC LAN

* Service Channels are available from High density D-Sub 44-pin connector
* When the mounted interface card support LAN ports, then SC LAN traffic can be assigned
* Service channels can be connected back-to-back at repeater stations.
TOPC-E4010E-01-07371 PASOLINK NEO 90
SERVICE CHANNELS

MUX PASOLINK NEO PASOLINK NEO MUX

V.11 & RS-232C E1 (MUX) E1 (DMR) E1 (MUX)


S V.11 & RS-232C F1 (MUX) F1 (DMR) F1 (MUX)
D V.11 DCCr (MUX) DCCr (DMR) DCCr (MUX)
V.11 & RS-232C DSC1 TO 4
H SC LAN DSC1 TO 4

V.11 & RS-232C


P SC LAN
DSC1 TO 4

D
H

TOPC-E4010E-01-07371 PASOLINK NEO 91


Principle of BB Linearlizer
IDU ODU

INTFC DPU BB LRZ MIX MIX AMP MIX AMP

Gain/Phase compensate AM-AM and AM-


PM of power amplifier Gain/Phase
AM-AM AM-PM

INPUT INPUT
AM-AM
AM-PM

improve Spectrum characteristic NOT FOR QPSK

TOPC-E4010E-01-07371 PASOLINK NEO 92


LOOP-BACK -PDH

(a) E1 CH # near-end loopback at the PDH INTFC module from the LCT
(b) E1 CH# far-end loopback at the PDH INTFC module from the LCT
(c) IF loopback (IF-LB) at the MODEM module (Local only)
(d) E1 CH# far-end loopback at the PDH INTFC Module from PNMTj/PNMSj

•Note: While the IF loopback is in execution, monitoring of the opposite and the subsequent stations from
the PNMSj and PNMTj are disabled.

TOPC-E4010E-01-07371 PASOLINK NEO 93


ETHERNET CONFIGURATIONS

TOPC-E4010E-01-07371 PASOLINK NEO 94


ETHERNET CONFIGURATIONS

TOPC-E4010E-01-07371 PASOLINK NEO 95


ETHER OVER E1 3

G732 Frame Structure


32TS:256bits/125us
8bit
TS0 TS1-15 TS16 TS17-31

Framing & CRC etc. Signaling CH


Multi frame structure Channel Associated Signaling(CAS)
Multi frame structure

Framing CRC CAS Type Description


Off - - Unframed All data bits are multiplexed
On Off Off PCM-31 All data multiplexed except TS0, no CRC
On On Off PCM-31C All data multiplexed except TS0,CRC yes
On Off On PCM-30 All data multiplexed except TS0/TS16, no CRC
On On On PCM-30C All data multiplexed except TS0/TS16, CRC yes

MDI MDI MDIX MDI


Wiring Wiring Wiring Wiring
1 TXD + 1 TXD + 1 RXD + 1 TXD +
21 TXD -+ 21 TXD -+ 21 TXD +-
RXD 21 TXD -+ The cable selection between the
3 RXD + 3 RXD + 3 TXD + 3 RXD +
41 TXD +
Cross
41 TXD + 41 TXD + 41 TXD +
LAN port and the external
Cable Straight Cable
5 5 5 5 equipment depends on the Mode
61 TXD +-
RXD 61 TXD +-
RXD 61 TXD -+ 61 TXD +-
RXD
setting. If Auto Negotiation is
selected it is possible to use either
MDI MDIX MDIX MDIX Straight or Cross cable.
Wiring Wiring Wiring Wiring
1 TXD + 1 RXD + 1 RXD + 1 RXD + If MID / MIDX is selected it is
21 TXD -+ 21 TXD +-
RXD 21 TXD +-
RXD 21 TXD +-
RXD necessary to select the correct
3 RXD + 3 TXD + 3 TXD + 3 TXD +
41 TXD + Straight Cable 41 TXD + 41 TXD +
Cross
41 TXD +
cable for connection
Cable
5 5 5 5
61 TXD +-
RXD 61 TXD -+ 61 TXD -+ 61 TXD -+

TOPC-E4010E-01-07371 PASOLINK NEO 96


ALARM TABLE
ALM ITEM DESCRIPTION ALM ITEM DESCRIPTION
ODU SDH INTFC
ODU ALM ODU TOTAL ALARM UNEQUIPPED SDH INTFC NOT MOUNTED
TX PWR ALM ODU OUT POWER DECREASED TYPEMISMATCH MOUNTED INTFC DIFFERENT FROM CONFIGURED
TX INPUT ALM TX IF INPUT LEVEL DECREASED MODULE ALM INTFC UNIT FAILURE
APC ALM ODU LOCAL OSCCILATOR UNLOCKED LOS (MUX) LOSS OF STM-1 SIGNAL FROM MUX
ODU CPU/CBL OPN ALM ODU CPU FAILURE OR IF CABLE OPEN LOF (MUX) LOSS OF STM-1 FRAME FROM MUX
RX LEV ALM ODU RECEIVED RF LEVEL LOW E-BER (MUX) EXCESSIVE BER DETECTED FROM MUX
LO REF ALM (XPIC) REFERENCE LO SIGNAL IS LOST E-BER (DMR) EXCESSIVE BER DETECTED FROM RADIO DIRECTION
MODEM SD (MUX) SIGNAL DEGRADE DETECTGED FROM MUX
UN EQUIPPED MODEM UNIT NOT MOUNTED LOS (DMR) LOSS OF STM-1 SIGNAL DETECTED FROM RADIO
MODULE ALM MODEM UNIT AILURE LOF (DMR) LOSS OF STM-1 FRAME DETECTED FROM RADIO
LOF LOSS OF RADIO FRAME SYNCHRONZATION IN MODEM SD (DMR) SIGNAL DGRADE DETECTED FROM RADIO
FRAME ID FRAME ID MISMATCH TF ALM TX FAIL ; NO STM-1 OUT PUT TO MUX
HIGH BER HIGH BER LEVEL DETECTED IN MODEM UAE (MUX) UNAVAILABLE COMDITION FROM MUX EXISTS
LOW BER LOW BER LEVEL DETECTED IN MODEM UAE (DMR) UNAVAILABLE CONDITION FROM RADIO EXISTS
EARLY WARNING EARLY WARNING CONDITION DETECTED IN CH # APS SW FAIL APS SW FAILURE
MOD ALM MODEM PLL UNLOCK, OUTPUT DOWN, CLOCK LOSS OUTPUT CONTROL STM-1 OUTPUT CONTROL APPLIED (MS-AIS GENERATION)
DEM ALM CARRIER / FRAME ASYNCH AT MODEM
INPUT VOLTAGE INPUT DC VOLTAGE HIGH OR LOW XPIC
POWERSUPPLY POWER SUPPLY FAILURE (1+1) ONLY XCTRL ALM XPIC CONTROL FAILURE
IF CABLE SHORT IF CABLE CONNECTED TO ODU IS SHORT CIRCUIT X IF ALM XIF SIGNAL IS LOW OR LOST
CABLE EQUALIZER CABLE EQUALIZER CONTROL IS LOST IN MODEM XREF ALM XPIC REF FREQUENCY IS LOST
LINEARIZER BB LNZ CONTROL IS LOST WS
PDH INTFC WS CH INPUT LOSS LOSS OF WS CH # INPUT SIGNAL
UNEQUIPPED INTFC NOT MOUNTED WS AIS RCVD AIS RECEIVED ON WS CH #, FROM MUX
TYPE MISMATCH MOUNTED INTFC DIFFERENT FROM CONFIGURED WS AIS GENERATED AIS IS GENERATED IN WS CH#
MODULE ALM INTFC HARDWARE FAILURE WS CH USAGE ERROR WS SIGNAL DETECTED IN NOT USED WS CH
INPUT LOSS CH # LOSS OF INPUT SIGNAL CH# FROM MUX ( E1 OR E3) LAN
AIS RCVD CH # AIS RECEIVED FROM CH # FROM MUX (E1 OR E3) LAN LINK LAN LINK FAILURE
AIS GENERATED CH # AIS GENERATED ON CH # (E1 OR E3) LAN COLLISION COLLISION OCCURRED IN LAN
CH USAGE ERROR CH# E1 SIGNAL DETECTED IN CH SET TO NOT USED LINK LOSS FORWARDING REMOTE LAN LINK FAILURE DETECTED
UAE UN AVAILABLE CONDITION FROM RADIO EXISTS

CTRL ALM CONTROL UNIT TOTAL ALARM

TOPC-E4010E-01-07371 PASOLINK NEO 97


Polarization Change

When shipped from factory the Guide


Pin is fixed to the Vertical plate. To
change polarization rotate the ODU and
screw in the Guide Pin to the hole in the
plate marked H.

V - Polarization
When ODUs are mounted on to
the NEC Hybrid, only V
polarization is used. The Hybrid
is set to V polarization when
shipped from the factory.
Rotate the TRANSITION HUB
plates as shown in the figure to
the right to change polarization.

H - Polarization

Note – Polarization can be changed if required to avoid interference


TOPC-E4010E-01-07371 PASOLINK NEO 98
I/0 BOARD FOR 48 E1 & 16E1

MDR(16E1) Æ D-Sub (2x8E1) Conversion Card

I/O BOARD FOR BNC (75 OHMS UNBALANCE)

TOPC-E4010E-01-07371 PASOLINK NEO 99


NEO POWER SUPPLY

SPARE FUSE

TOPC-E4010E-01-07371 PASOLINK NEO 100


NEO POWER SUPPLY WITH DC-DC CONV

TOPC-E4010E-01-07371 PASOLINK NEO 101


DC-DC CONV

SPARE FUSE

TOPC-E4010E-01-07371 PASOLINK NEO 102


LCT - MENU
PDH E1
Equipment Setup
LCT MAIN MENU PDH E1 with LAN
Alarm / Status Provisioning User Interface 4 Port LAN with E1
Equipment Setup PDH E3 with LAN
E3 Setting
Inventory SDH STM-1
AUX I/O CH # Used Not Used
CH Setting-1 1 + 0 (TERM)
Maintenance CH # LAN ( Status) 1 + 1 (Hot Standby TERM)
Provisioning Redundancy Setting
1 + 1 (Twin Path TERM)
Metering CH Usage Error Report
Report Not Report 2 WAY PDH (REP)
PMON (Current) AIS Generation Report
PMON (History) CH Setting-2
AIS Received Report 16 x E1 Standard PKG (E/W LAN)
AIS Received Condition Alarm Status INTFC (Work) 48 x E1 PKG
AIS Activation Condition LOF+HBER LOF 4 Port LAN with E1
E1 Port Impedance (CH#) 120 Ohms 75 Ohms
STM-1 (Optical)
High BER Threshold STM-1 (Electrical)
Low BER Threshold 1 x E3 +4E1 PKG (E/W LAN)
E-BER (DMR) 2 x E3 +8E1 PKG (E/W LAN)
BER Threshold Setting
SD (DMR)
Maintenance -1 E-BER (MUX) Not Used
CPU Reset SC Assignment SD (MUX) INTFC (Prot) STM-1 (Optical) for APS
Download Configuration File WS / LAN
Download Program File LAN PORT SETTING
Download Equip Config File Switching Function Disabled Enabled Not Used
Upload Configuration File 2M Frame XPIC Usage Used (Main Master)
Upload Equip Config File 2 Port Usage Used Not Used Used (SUB Master)
t
r
Date / Time Setting o Speed & Duplex
P APS Function Unavailable
Password Setting LAN Port Setting Flow Control ON OFF
1 Available
PMON Clear t
r Collision Report Report Not Report
o
P Link Loss Forwarding QPSK
Disabled Enabled
Modulation Scheme 16QAM
Maintenance -2 STM-1 Setting MS - AIS Generation Disabled Enabled 32QAM
Maintenance 128QAM
RX SW Manual Control ALS Function Disabled Enabled
ALS Function 10 [MB]
TX SW Manual Control ALS Interval 60Sec 180Sec 300Sec
TX Mute Control 20 [MB]
CW Control MTPC TX Power [dB] Transmission Capacity 40 [MB]
APS Manual Control ATPC Trehsold Level [dBm] 80 [MB]
IF Loopback Additional ATT [dB] 80 [MB]
TX RF Frequency[MHz] 100 [MB]
Main Loopback(Near End) TX Power Control ATPC Trehsold Level [dBm] RX RF Frequency[MHz]
Main Loopback(Far End) 156 [MB]
Additional ATT [dB]
Linearizer Control ATPC Range [MAX] [dB] Frame ID Frame ID 1 - 32
ALS Restart ATPC Range [MIN] [dB]
XPIC Control ATPC Power Mode Hold Max Min
MTPC
OFFLine Maintenance TX Power Control
TX SW Priority ATPC
DADE Adjust Non Priority Priority No.1
RF Setting RX SW Maintenance Mode NOT USED
Condition for TX/RX SW
Antenna Alignment Mode RX SW Priority Manual Forced P1-2 Shared/1 Port Only(Main)
LAN Port Usage (Main)
RX SW Condition Early Warning Include EW Exclude EW P1-2 Shared/1 Port Only(SC)
APS Maintenance Mode Manual Forced P1-2 Separated(Main)
APS Condition-SF(PROT) Priority High Priority Low
LAN Capacity (Main)
APS Condition-SD (B1) Include SD Exclude SD
Condition for APS Lock in Usage Used Notused
Lock in Count (times)
Lock in Detect Time (mins)
Lock in Hold Time (mins)

HK OUT 1 to 4 setting RL-3


RL-4
CLUSTER ALM OUT 1 to 4 setting RL-5
Relay Setting
PASOLINK ALM OUT setting RL-6
TCN Threshold (15min) CLUSTER ALM IN 1 to 4 setting Disabled Enabled
TCN Threshold (1day)
RX Level TCN Threshold [dBm]
PMON Select
SES Activation 30% 15%

XPIC Condition - Local Fail Mute REF LO>>Self LO


Others EOW2 Wxternal Setting Normal Invert
Alarm Correlation Capability OFF OFF

TOPC-E4010E-01-07371 PASOLINK NEO 103


Thank you

This training document describes the current version of the equipment.


The specifications or configuration contained in this document are subject to change
without notice.

TOPC-E4010E-01-07371 PASOLINK NEO 104


Release note (internal use only/Remove this page for distribution.)

070708:Issue 1 / Modified on draft by development Dept. check.


Page32/PASOLINK NEO IDU MODULES, Added H3031A/H3021C
Page68/SDH INTFC 2PORT LAN, LAN PORT 1&2 port control →SEPARATED MODE

TOPC-E4010E-01-07371 PASOLINK NEO 105

You might also like