Geometry:
A := 3.85 m Dimension Normal to Ridge θ := 0 Roof Angle
B := 8.5 m Dimension Parallel to Ridge
heave := 5.3 m Height of eave
hridge := 5.3 m Height of ridge
heave + hridge
h := = 5.3 m Mean Roof Height
2
2 s
2
qze := 0.613 Kze Kzt Kd V ( Pa) = 2.392 103 Pa
m2
2 s
2
qz := 0.613 Kz Kzt Kd V ( Pa) = 2.392 103 Pa
m2
2 s
2
qh := 0.613 Kh Kzt Kd V ( Pa) = 2.392 103 Pa
m2
Pressure Coefficients (NSCP Fig. 207B.4-1)
BN := B LN := A BP := A LP := B
pnww := pnww1 if (
max pnww1 , pnww2 )= pnww1
pnww2 otherwise
3
pnww = 2.057 10 Pa
3
Leeward Wall: pnlw1 := qh G Cpnlw - qh GCpi1 = -1.447 10 Pa
pnlw := pnlw1 if (
max pnlw1 , pnlw2 )= pnlw1
pnlw2 otherwise
3
pnlw = -1.447 10 Pa
3
Side Wall: pnsw1 := qh G Cpnsw - qh GCpi1 = -1.854 10 Pa
pnsw := pnsw1 if (
max pnsw1 , pnsw2 )= pnsw1
pnsw2 otherwise
3
pnsw = -1.854 10 Pa
pn1a := pn11a if (
max pn11a , pn12a )= pn11a
pn12a otherwise
3
pn1a = -3.073 10 Pa
Roof Pressure Coefficient, Cp: Case A
3
h/2 to h pn21a := qh G Cpn2a - qh GCpi1 = -1.854 10 Pa
pn2a := pn21a if (
max pn21a , pn22a )= pn21a
pn22a otherwise
3
pn2a = -1.854 10 Pa
3
h to 2h pn31a := qh G Cpn3a - qh GCpi1 = -1.854 10 Pa
pn3a := pn31a if (
max pn31a , pn32a )= pn31a
pn32a otherwise
3
pn3a = -1.854 10 Pa
3
> 2h pn41a := qh G Cpn4a - qh GCpi1 = -1.854 10 Pa
pn4a := pn41a if (
max pn41a , pn42a )= pn41a
pn42a otherwise
3
pn4a = -1.854 10 Pa
pn1b := pn11b if (
max pn11b , pn12b )= pn11b
pn12b otherwise
pn1b = -796.431 Pa
pn22b otherwise
pn2b = -796.431 Pa
pn3b := pn31b if (
max pn31b , pn32b )= pn31b
pn32b otherwise
pn3b = -796.431 Pa
pn4b := pn41b if (
max pn41b , pn42b )= pn41b
pn42b otherwise
pn4b = -796.431 Pa
ppww := ppww1 if (
max ppww1 , ppww2 )= ppww1
ppww2 otherwise
3
ppww = 2.057 10 Pa
3
Leeward Wall: pplw1 := qh G Cpplw - qh GCpi1 = -1.019 10 Pa
pplw2 otherwise
3
pplw = -1.019 10 Pa
3
Side Wall: ppsw1 := qh G Cppsw - qh GCpi1 = -1.854 10 Pa
ppsw := ppsw1 if (
max ppsw1 , ppsw2 )= ppsw1
ppsw2 otherwise
3
pnsw = -1.854 10 Pa
pp1a := pp11a if (
max pp11a , pp12a )= pp11a
pp12a otherwise
3
pp1a = -2.463 10 Pa
3
h/2 to h pp21a := qh G Cpp2a - qh GCpi1 = -2.158 10 Pa
3
pp22a := qh G Cpp2a - qh GCpi2 = -1.297 10 Pa
pp2a := pp21a if (
max pp21a , pp22a )= pp21a
pp22a otherwise
3
pp2a = -2.158 10 Pa
3
h to 2h pp31a := qh G Cpp3a - qh GCpi1 = -1.549 10 Pa
pp3a := pp31a if (
max pp31a , pp32a )= pp31a
pp32a otherwise
3
pp3a = -1.549 10 Pa
Roof Pressure Coefficient, Cp: Case A
3
> 2h pp41a := qh G Cpp4a - qh GCpi1 = -1.244 10 Pa
pp4a := pp41a if (
max pp41a , pp42a )= pp41a
pp42a otherwise
3
pp4a = -1.244 10 Pa
pp1b := pp11b if (
max pp11b , pp12b )= pp11b
pp12b otherwise
pp1b = -796.431 Pa
pp2b := pp21b if (
max pp21b , pp22b )= pp21b
pp22b otherwise
pp2b = -796.431 Pa
pp3b := pp31b if (
max pp31b , pp32b )= pp31b
pp32b otherwise
pp3b = -796.431 Pa
pp42b otherwise
pp4b = -796.431 Pa
h/2 to h -1.854
h to 2h -1.854
> 2h -1.854
Roof
0 to h/2 -0.796
Case B
h/2 to h -0.796
h to 2h -0.796
> 2h -0.796
Wind Direction Parallel to Ridge
Member Side Pressure (kPa)
Windward 2.057
Wall Leeward -1.019
Side -1.854
0 to h/2 -2.463
Case A
h/2 to h -2.158
h to 2h -1.549
> 2h -1.244
Roof
0 to h/2 -0.796
Case B
h/2 to h -0.796
h to 2h -0.796
> 2h -0.796