Diesel Generator Set Pjps-9 WP: 50 Hz/Prime Power/Fuel Consumption Optimized/ Water Cooled/Turbo/Charge Air Cooling

You might also like

Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 5

DIESEL GENERATOR SET

PJPS-9 WP
50 Hz/Prime Power/Fuel Consumption Optimized/
Water Cooled/Turbo/Charge Air Cooling

Optional equipment and finishing shown. Standard may vary.

PRODUCTHIGHLIGHTS
// Benefits // Complete range of accessories available
Easy starting and quick response Control panel
Long service intervals Circuit breaker/power distribution
High reliability Fuel system
High availability of power Fuel connections with shut-off valve mounted to base frame
Easy maintenance Starting/charging system
Exhaust system
Mechanical driven radiators
// Support
Low voltage alternators
Nationwide product support offered

// Power Rating
System prime ratings: 9 kVA
System standby rating up to 110% prime ratings with
maximum of 1 hour within 12 hours

// Voltage Regulation
Maintains voltage output to within +/-0.5%
At any factor between 0.8 lagging and unity
At any variation from no load to full load
At any variations from cold to hot temperature
2 / / / PJPS-9 WP / 50 Hz / 380V – 9kVA

APPLICATIONDATA

// Engine //CoolingRadiatorSystem
Manufacturer WuxiPerkins Fanpowerformech.radiator(40°C):kWm 0.3
Model 403A-11G1
Type 4-cycle //FuelConsumption
Arrangement 3in-line At100%ofpower rating:l/hr 3
Displacement:l 2.216 At75%ofpowerrating:l/hr 2.3
Bore:mm 77 At50%ofpowerrating:l/hr 1.7

Stroke: mm 81
Rated speed: rpm 1500 // System Ratings (kW/kVA)

Enginegovernor Mechanical Alternator PrimeRating


Voltage
Maxpower:kWm 8.6 Model kVA kWe
Aircleaner Dry Stamford
380 9 7.2
PI144D
// FuelSystem * cos phi = 0,8

Type Fuel Injection Pump


Fuel Tank Capacity : l 40

// Liquid Capacity (Lubrication)


Total oil system capacity: l 4.9

STANDARDANDOPTIONALFEATURES
Engine
// // Generator Cooling System
//
■ 4-Cycle Self-excited by PMG ■ Radiator Coolant
■ Standard single stage air filter ■ Superior voltage waveform ■ Jacket water pump
Oil drain extension & shut-off ■ Solid state, volts-per-Hertz ■ Thermostat(s)
valve regulator ■ Water charge air cooling
■ Closed crankcase ventilation ■ No load to full load regulation ■ Mechanical radiator
■ Governor-electronic isochronous ■ ±0.5% voltage regulation no load Electrical driven front-end cooler
■ Direct fuel injection to full load Jacket water heater
■ 12V DC starter ■ Brushless alternator with
brushless pilot exciter
■ 4 pole, rotating field
■ Class H insulation
■ IP 23 standard enclosure
■ Epoxy coated stator
Class F insulation
3 / / / PJPS-9 WP / 50 Hz / 380V – 9kVA

// Control Panel

■ Main control panel ■ AMF without ATS Mains parallel operation of


■ Digital metering Island operation multiple gensets

■ Engine parameters Automatic mains failure operation Expansion modules


■ Generator protection functions incl. control of generator and Remote annunciator
■ Engine protection mains breaker Generator winding temperature
Island parallel operation of monitoring
■ Parametrization software
multiple gensets Generator bearing temperature
■ Multilingual capability monitoring
Automatic mains failure operation
■ Multiple programmable contact
with short mains parallel overlap Differential protection relay
inputs synchronization Modbus RTU-TCP gateway
■ Multiple contact outputs Mains parallel operation of a SCADA system remote controller
■ Event recording single genset

Circuit Breaker/ Power


// // Fuel System // Starting/Charging System
Distribution

Daily tank control ■ 12V starter


■ 3-pole circuit breaker
Base frame mounted daily tank ■ Starter batteries
■ Manual-actuated circuit breaker
Electrical-actuated circuit ■ Flexible fuel connectors mounted ■ Battery rack & cables
breaker to base frame Battery charger
Fuel filter with water separator
Switchable fuel filter
with water separator

// Mounting System // Exhaust System // Others

■ Welded base frame Exhaust bellows with connection ■ Manual book


■ Modular base frame design flange ■ Spare part book
■ Engine and generator rubber ■ Industrial silencer ■ Warranty card
mounting Residential silencer ■ Factory test report
4 / / / PJPS- 9 WP / 50 Hz / 380V – 9 kVA

WEIGHTSANDDIMENSIONS

Drawing above for illustration purposes only, based on standard open power engine-generator set. Lengths may vary with other variances.

System Dimensions (L x W x H) Weight (dry/less tank)


Open Type 1650 x 730 x 1130 mm 352 kg
Silent Type 2100 x 1000 x 1530 mm 573 kg
Weights and dimensions are based on open type and are estimates only.

SOUNDDATA
// Consult PT. Conductorjasa Suryapersada energy consultant for sound data

EMISSIONSDATA
// Consult PT. Conductorjasa Suryapersada energy consultant for emission data

RATINGDEFINITIONSANDCONDITIONS
// Prime power ratings apply to installations where utility power is unavailable or unreliable. At varying load, the number
of generator set operating hours is unlimited. A 10% overload capacity is available for one hour in twelve. Ratings are
in accordance with ISO 8528-1, ISO 3046-1, BS 5514 and AS 2789. Average load factor: ≤ 75%.
// Deration factor:
Altitude: each 100 meter will cause power derating of 1%.
Temperature: Consult PT. Conductorjasa Suryapersada energy consultant for temperature derations.

Rated power is available up to 40°C and 400m above sea level.

Materials and specifications subject to change without notice.

PT CONDUCTORJASA SURYAPERSADA
A JERBINDO Systems Brand

www.conductorjasa.co.id

You might also like