PRODUCTHIGHLIGHTS
// Benefits // Complete range of accessories available
Easy starting and quick response Control panel
Long service intervals Circuit breaker/power distribution
High reliability Fuel system
High availability of power Fuel connections with shut-off valve mounted to base frame
Easy maintenance Starting/charging system
Exhaust system
Mechanical driven radiators
// Support
Low voltage alternators
Nationwide product support offered
// Power Rating
System prime ratings: 9 kVA
System standby rating up to 110% prime ratings with
maximum of 1 hour within 12 hours
// Voltage Regulation
Maintains voltage output to within +/-0.5%
At any factor between 0.8 lagging and unity
At any variation from no load to full load
At any variations from cold to hot temperature
2 / / / PJPS-9 WP / 50 Hz / 380V – 9kVA
APPLICATIONDATA
// Engine //CoolingRadiatorSystem
Manufacturer WuxiPerkins Fanpowerformech.radiator(40°C):kWm 0.3
Model 403A-11G1
Type 4-cycle //FuelConsumption
Arrangement 3in-line At100%ofpower rating:l/hr 3
Displacement:l 2.216 At75%ofpowerrating:l/hr 2.3
Bore:mm 77 At50%ofpowerrating:l/hr 1.7
Stroke: mm 81
Rated speed: rpm 1500 // System Ratings (kW/kVA)
STANDARDANDOPTIONALFEATURES
Engine
// // Generator Cooling System
//
■ 4-Cycle Self-excited by PMG ■ Radiator Coolant
■ Standard single stage air filter ■ Superior voltage waveform ■ Jacket water pump
Oil drain extension & shut-off ■ Solid state, volts-per-Hertz ■ Thermostat(s)
valve regulator ■ Water charge air cooling
■ Closed crankcase ventilation ■ No load to full load regulation ■ Mechanical radiator
■ Governor-electronic isochronous ■ ±0.5% voltage regulation no load Electrical driven front-end cooler
■ Direct fuel injection to full load Jacket water heater
■ 12V DC starter ■ Brushless alternator with
brushless pilot exciter
■ 4 pole, rotating field
■ Class H insulation
■ IP 23 standard enclosure
■ Epoxy coated stator
Class F insulation
3 / / / PJPS-9 WP / 50 Hz / 380V – 9kVA
// Control Panel
WEIGHTSANDDIMENSIONS
Drawing above for illustration purposes only, based on standard open power engine-generator set. Lengths may vary with other variances.
SOUNDDATA
// Consult PT. Conductorjasa Suryapersada energy consultant for sound data
EMISSIONSDATA
// Consult PT. Conductorjasa Suryapersada energy consultant for emission data
RATINGDEFINITIONSANDCONDITIONS
// Prime power ratings apply to installations where utility power is unavailable or unreliable. At varying load, the number
of generator set operating hours is unlimited. A 10% overload capacity is available for one hour in twelve. Ratings are
in accordance with ISO 8528-1, ISO 3046-1, BS 5514 and AS 2789. Average load factor: ≤ 75%.
// Deration factor:
Altitude: each 100 meter will cause power derating of 1%.
Temperature: Consult PT. Conductorjasa Suryapersada energy consultant for temperature derations.