1.YM217 Saturated Calomel Electrode (Double Salt Bridge) : Ionometers and Various

You might also like

Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 4

Beberapa Reference Electrode:

1.YM217 Saturated calomel electrode(Double salt bridge)

This electrode , as a PH electrode , can be used as a measuring element for analysis devices like
ionometers
and various indicator electrodes can form batteries to measure the ion concentration in
various solution, and to do potentiometric titration analysis
Technological index:
Mode Temp.rang Salt bridge materi Filled solution Jacket Dimentio connecto
l e al (mol/l) materia n r
(°C) l (mm)
217 5-55 ceramic grit core saturated KCL + optional soluti glass Φ12*120 instertio
on n

Electrode preservation
Polishing, ultrasonic process is completed, in room temperature dry to avoid light environment
preservation.
If you need to use ultrasound for further processing of the electrode , the following points should
be
noted
(a) is not appropriate electrodes placed directly on the bottom of the washer , to avoid too strong
ultrasonic electrode damage ;
(b) poly tetrafluoroethylene coat electrodes should avoid the use of hot cleaning liquid ;
(c) polyether ether ketone the electrode should avoid the use of strong acid -
type cleaning solution ( refer to the corrosion resistance of the PEEK material ) ;
(d) ultrasonic time not too long, generally not exceed 30s ;
(e) the container with the solution to be kept clean.
2. Y232 Saturated calomel electrode(single salt bridge)

This electrode , as a PH electrode , can be used as a measuring element for analysis devices like
ionometers and various indicator electrodes can form batteries to measure the ion concentration i
n various solution, and to do potentiometric titration analysis
Technological index:
Model Temp.range Salt bridge material Filled solution Jacket Dimention connector
(°C) (mol/l) material (mm)
Y232 5-55 ceramic grit core saturated KCL glass Φ12*120 instertion

3. Hg-Hg2SO4 electrode

Electrod
Reference electro temperature coefficie Filling
structure e application
de nt solution
potential
Hg- acid mediu
Hg/Hg2SO4/ SO4 0.1M K2S
Hg2SO4 electrode 0.615 -0.80 m
2-(a=0.1) O

Electrode preservation
Polishing, ultrasonic process is completed, in room temperature dry to avoid light environment p
reservation.
If you need to use ultrasound for further processing of the electrode , the following points should
be noted
(a) is not appropriate electrodes placed directly on the bottom of the washer , to avoid too strong
ultrasonic electrode damage ;
(b) poly tetrafluoroethylene coat electrodes should avoid the use of hot cleaning liquid ;
(c) polyether ether ketone the electrode should avoid the use of strong acid -
type cleaning solution ( refer to the corrosion resistance of the PEEK material ) ;
(d) ultrasonic time not too long, generally not exceed 30s ;
(e) the container with the solution to be kept clean.

4. 218 Ag/AgCl Reference electrode


This electrode can be used as a measuring element for analysis devices like ionometers and
variousindicator electrodes can form batteries to measure the ion concentration in various solution,
and to do potentiometric titration analysis
Technical parameters

Model No. 217 SCE 218 Ag/AgCl 232SCE K2SO4-1 RE-1A HgO
(double salt (single salt Mercury sulphate
bridges) bridge)
internal ≤10 ≤10 ≤10 ≤10 ≤10
resistanceK
compared ±3 ±4 ±3 ±3 ±3
potential Mv
Liquid ≤0.05 ≤0.05 ≤0.05 ≤0.05
circulation

Salt bridge saturated KCL saturated KCL saturated KCL Saturated K2SO4-
solution 1
Size Ø9*133mm Ø9*145mm Ø9*130mm Ø9*120mm Ø9*120mm
5. R0501 Mercury - mercury oxide electrode

Electrode Temperature
General
Name potential Coefficient
purpose
/V / mV
The standard mercuric Alkaline
0.098 -1.12
oxide electrode medium

Electrode preservation
Polishing, ultrasonic process is completed, in room temperature dry to avoid
light environment preservation.
If you need to use ultrasound for further processing of the electrode , the
following points should be noted
(a) is not appropriate electrodes placed directly on the bottom of the washer ,
to avoid too strong ultrasonic electrode damage ;(b) poly tetrafluoroethylene
coat electrodes should avoid the use of hot cleaning liquid ;(c) polyether ether ketone the electro
de should avoid the use of strong acid -type cleaning
solution ( refer to the corrosion resistance of the PEEK material ) ;
(d) ultrasonic time not too long, generally not exceed 30s ;
(e) the container with the solution to be kept clean.