Data Sheet Wöhr Parklift 413

Single unit = 3 cars Suitable for condominium and office buildings.


Double unit = 6 cars For permanent use only!*
free space for door 25 50 60 free space
* In case of short time user
– only possible on upper platform 25
40 38
and only if technically adjusted,
ask WÖHR!
Or with attendant or valet parking all
levels are possible for short time user.

door lintel
All platforms are in a horizontal
position to drive on.
The execution of the installation
can only be done with a roofing
provided from the customer h
side or within a building.
Load per platform max. 2000 kg
(load per wheel max. 500 kg)
X
X = only applicable if
garage doors are clear height
to be fitted for a lintel
Roller doors:
X = 15 max. + 3% slope
Sectional doors: max. -10% slope
X = 25 (single doors) 10
X = 30 (double doors)
15
X = to be clarified with 70 for
ning 15
door supplier ope and es
wallctrical servic
ele raulic
Dimensions in cm e hyd
ac
sp
le n
s si b c t i o
po r su

0
0 ss
fo

x2
x 5 ce
p s ge
m plu na
50 re
pu 2 ai
p 0 x d dr
um l 1 de
r s e en
fo ann mm
ch co
re

1–2% slope1–2% min.18


50
530–540

Standard type Compact type

C +30
C +30

Please attend to
+3 +3
restricted car- and
+3 +3 A 0 B 0 platform distance
A 0 B 0
height!

A B C h car height* A B C h car height*


Parklift 413-385/380: 385 380 555 180 175 Parklift 413-345/340: 345 340 495 160 155
Parklift 413-375/370: 375 370 540 175 170 Parklift 413-335/330: 335 330 480 155 150
* upper level, entrance level and lower level for cars and station wagons * upper level, entrance level and lower level for cars and station wagons

Clearance profile (car/station wagon)


40 170
50 50 170/ *The total car height
includes roof rail
175* and antenna fixture
(150/ and must not exceed
155*) the mentioned max.
275 22
60 14 38 height dimension.
Parklift 413 | 10.2012 | C027-4304 | © Otto Wöhr GmbH

120 max. 290 90


500

Notes
41. Clear platform width of 250 cm for car widths of 190 cm (see width dimensions stated on page 2). For large touring sedans we recommend
a clear platform width of at least 260–270 cm for single and 500 cm for double systems.
2. Due to recent increases in car length dimensions, and potential future developments, a pit length of 540 cm is advisable.
This offers bigger safety distances also for future cars.
3. At the edge of the pit a 10cm wide, yellow-black marking according to ISO 3864 has to be provided by the purchaser (see “statics and construction
requirements“ on page 3).
4. It is not possible to have channels or undercuts and/or concrete haunches along the pit floor-to-wall joints. In the event that channels or undercuts
are necessary, the system width needs to be reduced or the pit needs to be wider.
5. The manufacturer reserves the right to construction or model modifications and/or alterations. Furthermore, the right to any subsequent part
modification and/or variations and amendments in procedures and standards due to technical and engineering progresses in the art or due to
environmental regulation changes, are also hereby reserved.

Otto Wöhr GmbH Ölgrabenstrasse 14 Fon +49 [0] 7044 46 -0 www.woehr.de


01 Auto-Parksysteme 71292 Friolzheim | Germany Fax +49 [0] 7044 46 -149 info@woehr.de We compact parking space
Electrical datas Installation diagram
Item Performance Quantity Designation Position Frequency
1 by customer 1 unit electric meter in the feed cable 1 Electric meter
2 Fuse or automatic circuit breaker 3 x 25A slow blow
2 by customer 1 unit fuse or automatic circuit in the feed cable 1 per according to DIN VDE 0100 part 430
breaker 3 x 25 A slow blow power pack 3 Feed line to the main switch
acc. to DIN VDE 0100 p. 430 7 PVC control cable 5 x 2,52
6 Lockable main switch from main switch to assembly
3 by customer as locally acc. to local power supply feed cable to 1 per
required regulations main switch power pack
3 Ph + N + PE* 13 PVC control
conduit cable 7 x 1.5 2 8 Hydraulic unit with three-phase
4 by customer each equipotential bonding sa- corner pit floor/ motor, 230/400 V, 50 Hz, 5.5 kW.
10 m fety lead-out connection rear wall conduit Switching cabinet with motor,
protection, wired already for
5 by customer 1 unit equipotential bonding sa- from the lead-out 1 per installation
fety compliant to the connection to the Parklift 120 cm 110 cm 9 PVC control cable 5 x 1.52
DIN EN 60204 standard system
6 by customer 1 unit marked main switch, above operating 1 per 10 Branch connector
lockable to prevent device power pack
unauthorized switching on 14 Cylinder valve cable
PVC control cable 3 x 1.5 2
7 by customer 10 m PVC control cable with from main switch 1 per
marked strands and pro- to hydraulic power power pack 4 Equipotential bonding safety
tective conductor 5 x 2,52 pack lead-out connection
Items 8–14 are included in Wöhr’s scope of delivery unless otherwise specified in the 5 Equipotential bonding safety
from the lead-out connection
offer/order.
to the system
* DIN VDE 0100 part 410 + 430 (not under permanent load) 3PH+N+PE 12 Operating device for UP/DOWN with
EMERGENCY-STOP. If possible on the 11 PVC control cable 5 x 1.52
(three-phase current) Note: Where a door is used to close the garage, the left, but always outside the platform’s to the next facility
manufacturer of the door must be consulted before the electric cable is laid. movement range. Cables always feed in
from below. (2 keys per parking place.)
The electrical components enable our fitters to complete
suppliedbythemanufacturer their work satisfactorily and to
must be connected in accord- check the correct functioning
ance with the appropriate wiring of the units. Recesses and conduits for rotary
diagram and local regulations.
German VDE electrical require-
In compliance with the DIN EN switches with rolling and sectional gates
60204 standard provisions, all
ments must be adhered to, in systems must be connected Above plaster Under plaster
order to validate the TÜV tested directly on site with an earthed
circuit. equipotential bonding. The lead-
The electrical supply to the out connection must be at a
power pack(s) must be provided 10 m distance! 15
prior to or during installation to

Noise protection 115 above access level


Basis is the German DIN 4109 At differing constructional
“Noise protection in buildings”. conditions additional sound = = min.20 = =
With the following conditions absorbing measures are B B
required 30 dB (A) in rooms necessary. A A
can be provided: The best results are reached 7 +0,5
– noise protection package by separated sole plates from 8 8
from our accessory the construction.
Increased noise protection: A Plastic or steel armoured conduit M 20
– insulation figure of the
construction of min. R’w = 57dB If increased noise protection B Flexible plastic insulation pipe M 20
– walls which are bordering must be provided planning has
the parking systems must be to be confirmed on a project
done as single wall and basis by Wöhr (further building
measures are required). Railings
deflection resistant with min.
m’= 300 kg/m2 The units need to be provided acc. EN ISO 13857 with safety railings
if the gap between unit and wall exceeds 20 cm. If walkways are arranged
– solid ceiling above the directly to the side or behind the systems, railings have to be provided by
parking systems with min. client acc. to local requirements, height min. 200 cm – this is applicable
m’= 400 kg/m2 during the construction phase too.

Temperature
Parking place width
The installation is designed to operate between +5°and +40°C.
Atmospheric Humidity: 50% at +40°C. If the local circumstances We recommend a clear platform width of at least 250 cm and/or of
differ from the above please contact Wöhr. at least 500 cm for double systems.

Drainage Maintenance
We recommend the provision accessible for manual drainage, Regular maintenance by qualified personnel can be provided by means
of a drainage channel at the the client must provide a pump of an Annual Service Contract.
front of the pit which can either on site to empty the pump sump.
incorporate a pump sump To prevent any possibility Protection against corrosion
50 x 50 x 20 cm, or a connection of contamination of the ground-
into the storm water sewerage water we recommend that the Independent of a maintenance workings has to be carried out acc. to
system via a petrol/oil intercep- pit floor is coated with an oil Wöhr Cleaning and Maintenance Instruction regularly.
tor. If the pump sump is not proof paint. Clean up galvanized parts and platforms of dirt and road salt as well
Parklift 413 | 10.2012 | C027-4304 | © Otto Wöhr GmbH

as other pollution (corrosion danger)!


Conformity test Pit must be always ventilated and dearated well.
All our systems are checked according to EC machinery directive
2006/42/EC and EN 14010. Dimensions
All dimensions shown are minimum. Construction tolerances must
Illumination be taken into consideration. All dimensions in cm.
Illumination has to be considered acc. to local requirements by client.
Fire safety
Free spaces Each and every fire safety requirement and all possible mandatory item(s)
Special drawings for free spaces to accommodate air ducts or other and equipment(s) (fire extinguishing systems and fire alarm systems, etc.)
pipes can be requested at Wöhr Agent! are to be provided by the customer.

04
Width dimensions · Underground garages
All dimensions shown are minimum. Construction tolerances must be taken into consideration.
All dimensions in cm.
The access to the Parklift is possible with max. 3% declination and max. 10% inclination.

Wall to wall
Single unit (3 cars) Double unit (6 cars) Combinated unit (9 cars)
Wall openings required between
partitions for electrical and hydraulic
conduits must be provided where
applicable. Wall openings may not
S D D S be closed after installation.

B B B
T driving aisle width to
The
be compliant with country
Space required gives clear Space required gives clear Space required gives clear regulations locally in force.
B platform width B platform width B platform width
270 230 500 460 765 460+230
280 240 520 480 795 480+240
290 250 540 500 825 500+250
300 260 835 500+260
310 270 845 500+270
Other width combinations as well
as smaller widths are possible.

Pillars outside pit


Single unit (3 cars) Double unit (6 cars) Combinated unit (9 cars)

S S D D D S D S
min. 20 min. 20 min. 20

B B1 B B1 B B1
The driving aisle width to
be compliant with country
Space required Space required
S Space required regulations locally in force.
wall- pillar- gives clear wall- pillar- gives clear wall- pillar- gives clear
pillar pillar platform width pillar pillar platform width pillar pillar platform width
B B1 B B1 B B1
260
2 245 230 490 475 460 750 740 460+230
270 255 240 510 495 480 780 770 480+240
280 265 250 530 515 500 810 800 500+250
290 275 260 820 810 500+260
300 285 270 830 820 500+270
Other
O width combinations as well
as smaller widths are possible.

Pillars inside pit


Single unit (3 cars) Double unit (6 cars) Combinated unit (9 cars)

S S D D D S D S
min. 20 min. 20 min. 20

max.140 max.140 max.140


B B1 B B1 B B1
The driving aisle width to
be compliant with country
S
Space required Space required Space required regulations locally in force.
wall- pillar- gives clear wall- pillar- gives clear wall- pillar- gives clear
pillar pillar platform width pillar pillar platform width pillar pillar platform width
B B1 B B1 B B1
2
260 245 230 490 475 460 750 740 460+230
270 255 240 510 495 480 780 770 480+240
Parklift 413 | 10.2012 | C027-4304 | © Otto Wöhr GmbH

280 265 250 530 515 500 810 800 500+250


290 275 260 820 810 500+260
300 285 270 830 820 500+270
O
Other width combinations as well
as smaller widths are possible.

Important notes
If maximum platform widths are not installed, difficulties might For parking slots at edges or between walls, we recommend going
arise when entering or exiting the cars on the parking units. for our maximum platform widths.
This depends on the car type, the access and the individual For cars wider than 190 cm, platform width of 270/500 cm is
driving behaviour. required to enter and exit the car at drivers-side.

02
Width dimensions · Garages with doors
All dimensions shown are minimum. Construction tolerances must be taken into consideration.
All dimensions in cm.
The access to the Parklift is possible with max. 3% declination and max. 10% inclination.

Single garages (3 cars) Double garages (6 v)


B B x = for doors. See page 1

Wall openings required between


partitions for electrical and hydraulic
conduits must be provided where
S D applicable. Wall openings may not
be closed after installation.

X
B1 B1
20 20 20 20 The driving aisle width to
Space required gives clear Space required gives clear be compliant with country
B B1 platform width B B1 platform width regulations locally in force.
270 230 230 500 460 460
280 240 240 520 480 480
290 250 250 540 500 500
300 260 260
310 270 270

Serial garages with single doors (3 cars) Serial garages with double doors (6 cars)
B B1 B1 B B1

S S S D D

X
B2 B2 B2 B2 B2
20 32 32 32 20 32 32 The driving aisle width to
Space required gives clear Space required gives clear be compliant with country
B B1 B2 platform width B B1 B2 platform width regulations locally in force.
266 262 230 230 496 492 460 460
276 272 240 240 516 512 480 480
286 282 250 250 536 532 500 500
296 292 260 260
306 302 270 270

Statics and construction requirements


Single unit
P1 = +60 kN * Bearing loads are transmitted
+ P2 – P1 to the pit floor by base plates of
P3
clear P2 = + 9 kN approximately 700cm2, fixed by
– 3 kN heavy duty anchor bolts to a depth
platform of approximately 10–12 cm.
width +20 P3 = + 3 kN
Base plate thickness min. 18 cm.
+ P2 – P1 P3 Concrete quality according to the
static requirements of the building,
Marking according to ISO 3864 325 but for the dowel fastening we
13–30

require a concrete quality of min.


Double unit C20/25. When fixing to waterproof
P1 = +100 kN * concrete floors chemical anchors
+ P2 –
+ P2 – are employed (to be advised by
P1 P3 P3
P2 = +12 kN Wöhr).
– 6 kN The walls of the pit must be
P3 = + 3 kN formed of concrete and must
clear be perfectly flat and vertical
platform without any protrusions.
width +20
P1 The specified lengths to the
Parklift 413 | 10.2012 | C027-4304 | © Otto Wöhr GmbH

support points are mean values.


*all static loadings Please contact us for exact
+ P2 – P1 P3 include the weight 270 positions for any variations on
of the car the standard units.

Hydraulic power pack


The location of the hydraulic power pack is determined according to your Dimensions 1 single unit or 2–5 single units or
plan – space requirements are as follows: in cm 1 double unit 2–3 double units
Length: 100 200
Height: 140 140
Depth: 30 30

03