Pool Change Rate 4 HRS.: Input Data

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

Input Data

Pool Area 47.25 m2


Pool Depth 1.4 m
Pool Change Rate 4 hrs.
Filter Rate 30 m3/hr./m2
Area / Bather (a) 2.5 m2/person
Overflow Length (l) 35 m
Static Head (Pump Room to Pool Top 2 m
Total Pipe Length 40 m
Total Pipe Fittings Equivalent Length 25 m
Friction Loss 40 mm/m
Pressure Drop thru Filter 10 m
Pressure Drop thru Heat Exchanger 5 m
Pressure Drop thru DRV 0 m
Pressure Drop thru Inlet Fitting 5 m
Time for Initial Heating of Pool 24 Hours
Pool Required Temperature 28 C
Water Average Temperature 10 C

Output Data
Pool Volume 66.15 m3
Total Circulation Flow 16.5375 m3/hr.
Filter Area 0.55125 m2
Filter Diameter 0.9 m
No. of INLET FITTINGS 6
No. of OVERFLOW POINTS 3
Vv (Bathers Water Flow) 1.42 m3
Vw (Swell Water) 2.11 m3
Vr (Backwash Flow) 3.31 m3

Total Surge Tank Volume 6.84 m3


Circulation Pump Flow 16.5375 m3/hr
Circulation Pump Head 27.06 m
Heat Exchanger Capacity
PickUP Load 58 kW
Surface Losses 21.98 kW
Total Cap. 79.98 kW