FIT CALCULATION FOR ALTERNATOR SHAFT

&
COUPLER HUB

Given Data:
Shaft Dia. of Alternator:
Dmax = 85.712 mm
Dmin = 85.687 mm

Bore Dia. of Coupler Hub:


Dia. = 85.687 H6
IT Grade Deviation Limit
Dmax = 85.709 mm
+0.022 85.709
H6
Dmin = 85.687 mm 0 85.687

TYPE OF FIT:
Clearance fit:
The max. diameter of the shaft is smaller than the min. diameter of the bore/hole.
Therefore;

 (Dmax) shaft < (Dmin) hole


Or;
85.687mm – 85.712mm = -0.025mm
Hence, there is no min. clearance available.
Interference fit:
The min. diameter of the shaft exceeds the max. allowable diameter of the bore/hole.
Therefore;

 (Dmin) shaft > (Dmax) hole


Or;
85.709mm – 85.687mm = 0.022mm
Hence, there is no interference.

Transition fit:
The max. diameter of the bore/hole is greater than the min. diameter of the shaft.
Also, the min. diameter of the bore/hole is smaller than the max. diameter of the shaft.

 (Dmax) hole > (Dmin) shaft


 (Dmin) hole < (Dmax) shaft
Or;
85.709mm – 85.687mm = 0.022mm
85.687mm – 85.712mm = -0.025mm

Hence, the type of fit is Transition.

Prepared by: Checked by:


Maarij Anjum Awad Atif