Fit Calculation For Alternator Shaft
Fit Calculation For Alternator Shaft
&
COUPLER HUB
Given Data:
Shaft Dia. of Alternator:
Dmax = 85.712 mm
Dmin = 85.687 mm
TYPE OF FIT:
Clearance fit:
The max. diameter of the shaft is smaller than the min. diameter of the bore/hole.
Therefore;
Transition fit:
The max. diameter of the bore/hole is greater than the min. diameter of the shaft.
Also, the min. diameter of the bore/hole is smaller than the max. diameter of the shaft.