Professional Documents
Culture Documents
Flowmeters TA 0810 E
Flowmeters TA 0810 E
in-line weighing of dry bulk solids with accurate, repeatable results. Conve-
nient, accurate, and dust-tight, flowmeters offer field proven technology for
consistent performance.
Weighing Technology
Answers for industry.
1
Trends in Weighing
by improving quality and lowering costs. span of the integrator. They generally do
Solids flowmeters have proven to be a not require maintenance or recalibration
convenient, accurate, and dust-tight after the initial installation and material
Material flow alternative for continuous in-line weigh- tests. Finally, most solids flowmeters
ing. By measuring the impact of material have dust-tight construction, making
flow, these alternatives to conventional them suitable for use in hazardous areas
weighing devices provide accurate, con- or in applications that require minimal
tinuous measurement of free-flowing cleanup and reduced housekeeping, such
solids. To accomplish this it is important as milling and food processing.
Flowguide to understand how to properly select,
Sensing plate
install, calibrate, and interface a solids Solids flowmeters continuously weigh
flowmeter for a particular application. a variety of materials, from powders to
granules larger than one inch in diam-
Horizontal force dependent eter. Suitable material densities range
Horizontal
from puffed wheat to iron ore. Flowabil-
force
Solids flowmeters are impact-weighing ity suitable for solids flowmeters covers
devices that measure the mass flow rate the spectrum from fluidized powder,
of a free-flowing, continuous stream of such as fly ash, to lathe turnings. Suc-
dry solids material. The principle of op- cessful applications include grain tailings
eration is simple: The material produces and screenings, cement, soybean and
a mechanical deflection as it strikes the rice hulls, gravel, unshelled peanuts,
flowmeter's sensing plate. The flowmeter wood chips, starch, coke, sugar, potato
Diagram 1: Solids flowmeters monitor dry bulk converts the deflection into an electrical flakes, coal, and plastic pellets.
materials in sizes from powders to granulates up to signal that feeds into an accompanying
25 mm (1") in diameter, measurement is only made integrator, which instantaneously displays Models are available in flow rate ranges
in the horizontal plane
the flow rate and integrated total weight. from 500 pounds per hour to 900 tons
per hour. By using material samples,
The flowmeter measures only the hori- solids flowmeters calibrate to ±1% of full
zontal component of the force of the ma- scale and provide ±0.2% repeatability.
Silica terial flow striking the plate. It is critical Many applications have accuracies of
sand these following factors remain constant ±0.5% or better. Users can commonly
PID for reliable and repeatable measure- expect a 3 to 1 flow rate turn-down ratio
ment. The horizontal force is dependent from most suppliers.
Rotary feeder
on particle mass, velocity of the particle,
angle of impact of the particle against Types of flowmeters
the plate, and the energy absorbing char-
acteristics of the particle. There are two basic types of impact flow-
meters: the linear variable differential
Flowmeter
Thus, with these factors held constant, transformer (LVDT) and the strain gauge
Integrator the flowmeter responds to the mass or load cell. Each type uses a different
weight of the material striking the plate. sensor to convert the horizontal force
Because the flowmeter measures only applied to the sensing plate. In general,
Pebble mill
the horizontal force, it is unaffected by selecting the appropriate flowmeter de-
vertical force changes caused by material pends upon both the flow rate and the
buildup on the non-sensing area of the temperature of the weighed material.
sensing plate. Consequently, there is no
zero drift, which in turn eliminates the LVDT models use a range spring, which
need for frequent recalibration. offers an opposing force to the material
Diagram 2: To control feed for the grinding process
flow, and a viscous fluid damper, which
in a silica sand application, the flowmeter and The current generation of solids flow- eliminates pulses in the movement of the
integrator control a rotary airlock feed to maintain meters available on the market provides sensing plate. The weighing mechanics
a set rate of material flow. several advantages over earlier models, are externally located, so they are unaf-
including lower cost and improved mate- fected by the material being processed.
rial flow for more accurate measurement. A mechanical stop serves for overload
As weighing devices, solids flowmeters protection. These flowmeters measure
offer several advantages over other sys- materials with temperatures up to 450°F
tems. They can work in situations where when silicon gaskets are used. Capacities
other weighing devices are inappropri- range from 40 tons per hour to 300 tons
ate. Their compact size allows you to per hour, depending on the model.
install them without major modification.
They easily and accurately calibrate by Inherent opposing force
comparing the weight of a measured
material sample to the weight totalized Strain gauge load cell models support,
by the flowmeter and then correcting the or assist in supporting, the sensing plate
2
Applying impact flowmeters
3
Trends in Weighing
Siemens flowmeters are heavy-duty and require little maintenance. They have a totally
enclosed design to eliminate product waste or contamination and reduce plant maintenance.
Since the units are dust-tight, they create a healthier work environment, especially when
hazardous substances are monitored.
Information considered by the factory in particularly the velocity of the material, You should calibrate the solids flowmeter
applying the most appropriate solids flow- impact angle on the sensing plate, energy in accordance with the manufacturer's
meter includes: absorbing characteristics, and coefficient guidelines and timetable. Like any type of
• Material of friction. Solids flowmeters are rela- continuous weighing device, it is impor-
• Flow rate tively immune to vibration. The rules for tant that consistency is of primary impor-
• Type of preferred device application when vibration exists are as tance and then accuracy. Generally cali-
• Bulk density follows: If you can only feel the vibration, bration procedures include the following:
• Temperature don't be concerned; if you can see the • Ensure the integrity of flowmeter in-
• Particle size vibration, take measures to reduce it. The stallation
• Abrasiveness, particularly if it is a spe- same guideline may apply to air flow past • Determine calibration weight value in
cialty material the sensing plate. If the air flow is great accordance with factory specifications
• Accuracy required enough to feel directly on the skin then it • Perform zero calibration
• Possibility for a material test will likely affect accuracy. • Perform test weight span calibration
• Airflow • Recheck to verify the zero calibration
• Material aeration You should install a solids flowmeter on • Perform material tests if possible
• Corrosiveness the level and securely. Wiring should be in • Perform at least three tests before the
• Moisture content accordance with local laws as well as gen- final adjustment happens
• Hazardous area classification erally accepted principles for instrumenta-
tion and continuous weighing equipment. If the device is repeatable, perform a
Application and installation are critical to The wiring should have protection from manual span adjustment and factor the
reliable and accurate solids flowmeter op- damage and electrical noise. test weight to the material test.
eration. It is certain that the performance
of a solids flowmeter is only as good as the One of the most critical aspects of solids Dry solids flowmeters help to enhance
application and installation of the device. flowmeter performance is the use of an process control, improving
appropriate prefeed device. A prefeed product quality and saving on operational
Factors affecting accuracy include mate- device conditions the material prior to costs. Flowmeters provide continuous
rial consistency, air flow past the sensing weighing. A user may also control the in-line weighing of dry bulk solids with
plate, vibration, and installation. The ma- flow rate by controlling the speed of the repeatablity and accuracy.
terial consistency must remain constant, prefeed device.