Data heater_CMFS150M__FCS

Coriolis Flowmeter Calculation Summary Quote/Rev No: -/-

Date: 2019-08-28
Company: -
Project Name: -
Service: Medición de flujo de pozo
Sensor Model Name : CMFS150M
Sensor Model #: -
Sensor Tag(s): FIT-0001
Transmitter Model Name : -
Transmitter Model #: -
Transmitter Tag(s): -
Wetted Material: 316L
Fluid: Crude oil, Ratawi (24.5 API, 11.8 K-factor)
Fluid State: Liquid
Mass Flow Accuracy at Operating Flow (+/- % of Rate) 0.1000
Pressure Drop at Operating Flow 9.3099 psig
Velocity at Operating Flow 19.7349 ft/sec
Min Operating* Max Design Units
Barrels(Oil)/da
Flow Rate: 1,000.0000 2,000.0000 3,000.0000 -
y
Pressure: 300.0000 600.0000 1,200.0000 - psig
Process Fluid Temperature: 20.0000 30.0000 100.0000 - C
Ambient Temperature: 15.0000 30.0000 45.0000 - C
Density: 7.5524 7.5051 7.1642 0.0000 lb/Gallon(US)
Viscosity: 50.4920 36.0249 5.6273 - cP
-
Base Reference Temperature: C

Gas Only Base Reference Pressure: bar-a -


Base Reference Density: kg/m3 -
Process Connection: -
Process Connection Pressure Rating: -
@Temperature: 100 C
Velocity at
Mass Flow Accuracy at Operating Pressure
Flow Rate Barrels(Oil)/day psig Operating ft/sec Re
Flow (+/- % of Rate) Drop*
Flow

0.12 24
Pressure Drop (psi...

0.10 20
Flow Accuracy

0.08 16 Flow
Accuracy
0.06 12
Pressure
0.04 8 Drop
0.02 4
0.00 0
2000.0000
1080.0000
1160.0000
1240.0000
1320.0000
1400.0000
1480.0000
1560.0000
1640.0000
1720.0000
1800.0000
1880.0000
1960.0000
2040.0000
2120.0000
2200.0000
2280.0000
2360.0000
2440.0000
2520.0000
2600.0000
2680.0000
2760.0000
2840.0000
2920.0000
3000.0000

Flow Rate (Barrels(Oil)/day)

* All pressure drop and velocity results are based on the process conditions (except flow rate) that are entered in the Operating column.