Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

293-PI-T-001 293-PP-403 293-PP-410 293-TK-401 293-PP-401 293-PP-402 293-FL-401 NOTES:

RAW WATER COPPER SX COPPER PLS FILTER COPPER PLS FILTER COPPER PLS FILTER COPPER PLS FILTER
BOOSTER PUMP SUBMERSIBLE PUMP FEED TANK FEED PUMP FEED PUMP 1. FOR GENERAL NOTES, SEE DRAWING 000-PI-T-001.
(STANDBY)

PI V
1001

FROM PLANT AIR


DISTRIBUTION
3"-PA-293-127-L8B-IC 1"-A-15
2795 265-PI-T-006
LFF1 V
S/D 3"-A-16 3"-C-22 FV
XU +

1002
I I LCS
PP403M
1/2"-PA-293-120-L8B
VENT TO ATM

M
FROM 293-LIC-0041
FROM RAW WATER 4"x3" 4"-RW-293-061-L1B 293-PI-T-002 2788
HEADER
6"-RW-262-049-L1B 6"x4" I
2791 262-PI-T-007 4"-A-16 4"-C-22 V
6"-A-16 4"-SPJ-1 PCV
+

1003
293-PP-403

FROM PRIMARY V
GYPSUM THICKENER
LSLL HV
+
285-TK-097 0002 1004
6"-ASL-293-022-P7 LAHH
2701 285-PI-T-020
LIC LAH
V1Z
0002
LAL
LALL

OVERFLOW
I
TO COPPER PLS TANKS
293-TK-404/416
LVF1 6"-ASLL-293-016-S1
2792 293-PI-T-003
PSH
XU 6"-A-15-GO
8"-ASL-293-073-P4

I 0012
PP401M NC
PAH
PI
0012 PAL
LCS I
FIC FAH
0011 V V
FAL ZS ZS
V V
LIT PIT HV HV
VFD 1013 1014
0002
+ +

1005

3"x1-1/2"
0012 1006
FE FIT V
V1Z LSH
HV +

V1Z M + 0011 0011 FC FC


HV 0007 1015
+
3 1"-A-15
3"-A-15 0005
4"x2" 6"x4" NC 6"x4" 6"x4"
6"x3" 3"-SPJ-1H
M
6"-ASLL-293-074-S1 4"-RW-293-061-L1B
4"-C-23 4"-A-15 4"-A-15
1"-A-15 V
NC V

6"-ASLL-293-075-S1
6"-A-15-GO 6"-A-15-GO
1"-A-15 NC LSM
TO FLOOR NC 293-TK-401 V1Z NC 1"-A-15 1016
ZS
3 PDIT
293-PP-401 1022
NC
LVF1 4"-E-18 1017
HV NC
+ XU V
0006 I
PP402M HV TO COPPER FILTER
V
+

1007 HV PRECOAT TANK


293-FL-401

6"-ASLL-293-077-S1
+ 293-TK-403
1009 6"-PSH-293-018-S1
FC
6"-ASLL-293-076-S1

2789 293-PI-T-002
LCS I

V
HV
VFD FC +
V I 1012
HV
+
V V1Z
V1Z 1008 HV
V
M 3 HV LSL + TO COPPER PLS FILTER
3
+ 1010 SLUICE TANK
0008 FC 1023 293-TK-405
4"x2" 6"x4" 6"-ASLL-293-004-S1
2797 293-PI-T-002
6"x3" 3"-SPJ-1H V FC
NC AI AIT
4"-C-23
1"-A-15 1021 1021 V
HV
1"-A-15 NC +
TO COPPER PLS TANKS
TURBIDITY 1011
FROM COPPER PLS FILTER
PRECOAT PUMP
NC 293-PP-402 6"x4" 6"x4" 293-TK-404/416

293-PP-404 (STANDBY) TURBIDITY 2790 293-PI-T-003

2798 293-PI-T-002
6"-ASLL-293-079-S1 V V FC
AE V
1021
LFF1 I V
LAHL
0001 XU
I 4"-E-18
PP410M NC
LI
0001 TO COPPER RAFFINATE TANK
LCS I 3"-SU-293-074-P7
293 TK-406
3"-SU-293-074-P7
2909 293-PI-T-004
3"-A-15 3"-A-15
LIT LE 3"-C-23
NC
0001 0001
3"-SPH-15

TO COLLECTION DITCH
3"-SU-293-025-P7
2793 255-PI-T-007
3"-A-15
M NC
DRAW ING NOT VALID W ITHOUT SIGN AND STAMP OF DOCUMENT CONTROL
3"x2"
QUALITY CONTROL

DISCIPLINE MANAGER NAME SIGN


293-PP-410 DOCUMENT CONTROL

THIS DRAW ING NOT VALID UNLESS THE LATEST REVISION INITIALS ARE HANDW RITTEN NAME SIGN AND STAMP

SCALE : PROJECT
REFERENCES REVISIONS REVISIONS NOTICE SHEET SIZE

DWG. NO. TITLE NO. DESCRIPTION BY CHECK APPROVED DATE NO. DESCRIPTION BY CHECK APPROVED DATE
A1 TOROMOCHO PROJECT
THIS IS A COMPUTER GENERATED DRAWING. ALL
000-PT-T-001 PIPING LEGEND P & ID A ISSUED FOR REVIEW MKM JHL JHL 04/29/11 CHANGES HERE TO SHALL BE PERFORMED USING
AREA
CADD ONLY. DRAW N BY: ZDM/MKM DATE : 04/11/11 293-Copper Solvent Extraction C-560 REVISION
000-PI-T-002 INSTRUMENTATION LEGEND P & ID B ISSUED FOR CLIENT APPROVAL MKM PT JHL RC 05/03/11 THIS DRAWING IS THE PROPERTY OF AND EMBODIES
PROPRIETARY INFORMATION BELONGING TO AKER TITLE CAD NO.
SOLUTIONS AND MUST BE RETURNED IMMEDIATELY CHECKED BY: JHL DATE : 06/23/11
000-EL-M-001 MECHANICAL EQUIPMENT LIST,REV. 1. C RE-ISSUED FOR APPROVAL JMR JHL JHL RC 05/10/11 UPON REQUEST. IT MUST NOT BE COPIED IN WHOLE
OR IN PART, NOR THE INFORMATION SHOWN THERE
ON DISCLOSED TO THIRD PARTIES EXCEPT WITH THE
293-FS-T-002 COPPER EW FLOWSHEET 0 ISSUED FOR CONSTRUCTION MKM JHL JHL RC 05/23/11 JHL DATE : 06/23/11 560-293-PI-T-001
WRITTEN PERMISSION. APPROVED BY: COPPER PLS 3
1 UPDATED & RE-ISSUED FOR CONSTRUCTION MKM JHL JHL RC 06/23/11
AUTHORIZED BY: RC DATE : 06/23/11 FILTRATION
UPDATED AND RE-ISSUED FOR CONSTRUCTION. CAC JHL JHL RC 08/26/11 DWG. NO.
2
MINERA CHINALCO PERU S.A. P & ID
3 UPDATED AND RE-ISSUED FOR CONSTRUCTION. SMF MMB JHL RC 05/02/12
MCP APPROVED: TO DATE : 05/23/11 293-PI-T-001
09-05-2012 10:35:48
293-HS-401 293-BG-401 293-SC-401 293-CH-401 293-TK-403 293-AG-403 293-TK-405 293-PP-404 293-AG-405 293-PP-407 NOTES:
293-PI-T-002
COPPER PLS FILTER COPPER PLS FILTER COPPER PLS FILTER COPPER PLS FILTER COPPER PLS FILTER COPPER PLS FILTER PRECOAT COPPER PLS COPPER PLS FILTER COPPER PLS FILTER SLUICE COPPER PLS FILTER
PRECOAT HOIST PRECOAT PRECOAT PRECOAT PRECOAT TANK TANK AGITATOR SLUICE TANK PRECOAT PUMP TANK AGITATOR SLUICE PUMP 1. FOR GENERAL NOTES, SEE DRAWING 00-PI-T-001.
BAG UNLOADER SCREW FEEDER FEED CHUTE 2. REMOVABLE SPLIT COVER, FRP.

TO PLS FILTER PLC


293-PI-T-001 2788

SAL
0050
FROM COPPER PLS FILTER
293-PI-T-401
6"-ASLL-293-018-S1
2789 293-PI-T-001
6"-A-15-GO

LFF1
XU
293-HS-401 AG403M

LVF1 I
293-BG-401
XU LAH
I V LSH
SC401M SSL
0041
0050
I LCS
293-SC-401
LCS I VFD M
M LFF1
LSL LAHH XU
SIC 293-CH-401 0041 PP404M
SC401M LALL
(NOTE 2)
LSLL
0041
I
PI PAH
0046 PAL
8"-ASLH-293-081-P4

LIC FI
I LCS
0041 0048
PIT
0046
LIT FIT
FE
0041 +
0048
M 3 0048
6"-ASLL-293-080-S1 1"-A-15 TO COPPER PLS FILTER
6"x4" 293-FL-401
6"x3" 6"x4" 6"-ASLL-293-079-S1
3"-A-15 6"x4" M 2798 293-PI-T-001

6"-C-23 2"-A-15 6"-A-15-GO


NC 1"-A-15
6"-A-15-GO 2"-A-15 4"-SPJ-8 NC
TO FLOOR 4"-A-15 NC
NC 293-TK-403 293-PP-404
293-AG-403
LFF1
XU
AG405M

FROM COPPER PLS FILTER


293-FL-401
6"-ASLL-293-004-S1
2797 293-PI-T-001
LCS I
6"-A-15-GO
LSH LSL LI LAHH

M 0047 0047 0047

START

STOP
LFF1
8"-ASLL-293-005-F1

XU
LIT PP407M
0047
I I LCS
PAHH
PSHH
0049
3"-A-15 PAH
4"-ASLL-293-011-S2 PI
4"-A-15 1M 0049
NC 4"-A-15
1"-A-15
TO FLOOR 293-TK-405 NC
PIT
293-AG-405
4"x3" 0049

S1 P7
TO COPPER SX

M
1"-A-15 RAFFINATE TANK
293-TK-406
3"x2" 3"-ASLL-293-013-S1 3"-ASLL-293-012-P7 2805 293-PI-T-004

3"-C-23 3"-A-15 1"-A-15


293-PP-407 1"-A-15
NC NC

DRAW ING NOT VALID W ITHOUT SIGN AND STAMP OF DOCUMENT CONTROL

QUALITY CONTROL

DISCIPLINE MANAGER NAME SIGN


DOCUMENT CONTROL

THIS DRAW ING NOT VALID UNLESS THE LATEST REVISION INITIALS ARE HANDW RITTEN NAME SIGN AND STAMP

SCALE : PROJECT
REFERENCES REVISIONS REVISIONS NOTICE SHEET SIZE

DWG. NO. TITLE NO. DESCRIPTION BY CHECK APPROVED DATE NO. DESCRIPTION BY CHECK APPROVED DATE
A1 TOROMOCHO PROJECT
THIS IS A COMPUTER GENERATED DRAWING. ALL
000-PI-T-001 PIPING LEGEND P & ID A ISSUED FOR REVIEW MKM JHL JHL 04/29/11 CHANGES HERE TO SHALL BE PERFORMED USING
AREA
CADD ONLY. DRAW N BY: ZDM/MKM DATE : 04/11/11 293-Copper Solvent Extraction C-560 REVISION
000-PI-T-002 INSTRUMENTATION LEGEND P & ID B ISSUED FOR CLIENT APPROVAL MKM PT JHL RC 05/03/11 THIS DRAWING IS THE PROPERTY OF AND EMBODIES
PROPRIETARY INFORMATION BELONGING TO AKER TITLE CAD NO.
SOLUTIONS AND MUST BE RETURNED IMMEDIATELY CHECKED BY: JHL DATE : 06/23/11
000-EL-M-001 MECHANICAL EQUIPMENT LIST, REV. 1. C RE-ISSUED FOR APPROVAL JMR JHL JHL RC 05/10/11 UPON REQUEST. IT MUST NOT BE COPIED IN WHOLE COPPER
OR IN PART, NOR THE INFORMATION SHOWN THERE
ON DISCLOSED TO THIRD PARTIES EXCEPT WITH THE
293-FS-T-001 COPPER SX FLOWSHEET 0 ISSUED FOR CONSTRUCTION MKM JHL JHL RC 05/23/11 JHL DATE : 06/23/11 560-293-PI-T-002
WRITTEN PERMISSION. APPROVED BY: PLS FILTER 3
1 UPDATED & RE-ISSUED FOR CONSTRUCTION MKM JHL JHL RC 06/23/11
AUTHORIZED BY: RC DATE : 06/23/11 PRECOAT & SLUICE
UPDATED AND RE-ISSUED FOR CONSTRUCTION. CAC MMB JHL RC 08/26/11 DWG. NO.
2
MINERA CHINALCO PERU S.A. P & ID
3 UPDATED AND RE-ISSUED FOR CONSTRUCTION. SMF MMB JHL RC 05/02/12
MCP APPROVED: TO DATE : 05/23/11 293-PI-T-002
09-05-2012 10:55:17
293-TK-404 293-TK-416 293-PP-405 293-PP-406 293-SA-041 NOTES:
293-PI-T-003
COPPER PLS TANK COPPER PLS TANK COPPER PLS FEED PUMP COPPER PLS FEED PUMP COPPER PLS SAMPLER
(STANDBY) 1. FOR GENERAL NOTES, SEE DRAWING 000-PI-T-001.
2. FOR COMMISSIONING, BYPASS BACK TO 293-FL-401,
COPPER PLS FILTER FEED TANK, REF.: 293-PI-T-001.
3. TO BE SPECIFIED BY AKER SOLUTIONS INTERLOCK TABLE,
000-LT-I-205, AT A LATER DATE.

FROM COPPER PLS FILTER


293-FL-401 (NOTE 2)
6"-PSH-293-017-S1 6"-PSH-293-017-S1
2790 293-PI-T-001
6"-A-15-GO

6"-A-15-GO

FROM COPPER FILTER


FEED PUMPS HS
293-PP-401/402 0085
6"-ASLL-293-016-S1
2792 293-PI-T-001
FILTER BYPASS

LSL LIC LAH LSL LIC LAH


0082 0082 0083 0083
LAL LAL

6"-PSH-293-019-S1
I
S/D

8"-PSH-293-027-P4
TI
TI

8"-PSH-293-026-P4
0088
0089
LIT LIT
TIT 0082 0083
TIT
0088
0089

3"-A-15 3"-A-15
TE TE
6"-PSH-293-020-S1 6"-PSH-293-021-S1
0088 0089

6"-A-15-GO 6"-A-15-GO 6"-A-15-GO 6"-A-15-GO

6"-A-15-GO 6"-A-15-GO
TO FLOOR NC 293-TK-404 293-TK-416 TO FLOOR
NC

LVF1
FROM SX PLANT S/D INTERLOCK
S/D XU
3034 (NOTE 3) I
PP705M
(VENDOR FOAM SYSTEM)

FAH TO 293-FIC-0128
FIC
2809 293-PI-T-005
LCS I 0085
FAL

6"-PSH-293-022-S1
RATIO CONTROL

VFD
FIT
0085 FE
M 3 PP1"-SPH-6A +

0085
1"-A-15 TO E-1 PUMP MIX TANK
4"x3" NC 6"x4" 6"-PSH-293-023-S1
293-TK-412
M 2806 293-PI-T-004
6"x4"
4"-C-23 4"-A-15 4"-A-15 4"-A-15 1"-A-15
1"-A-15 NC
1"-A-15 4"-SPJ-1H NC
NC 1"-A-15 4"-A-15
293-PP-405 NC NC
4"-E-18
NC 293-SA-041
6"-A-15-GO

LVF1 SAMPLING
S/D XU
1"-A-15 I 706M
NC 6"-A-15-GO
NC

LCS I

VFD

M 3

4"x3" 4"-C-23
6"x4"

4"-SPJ-1H
1"-A-15
1"-A-15 293-PP-406 NC
NC (STANDBY) DRAW ING NOT VALID W ITHOUT SIGN AND STAMP OF DOCUMENT CONTROL

QUALITY CONTROL

DISCIPLINE MANAGER NAME SIGN


DOCUMENT CONTROL

THIS DRAW ING NOT VALID UNLESS THE LATEST REVISION INITIALS ARE HANDW RITTEN NAME SIGN AND STAMP

SCALE : PROJECT
REFERENCES REVISIONS REVISIONS NOTICE SHEET SIZE

DWG. NO. TITLE NO. DESCRIPTION BY CHECK APPROVED DATE NO. DESCRIPTION BY CHECK APPROVED DATE
A1 TOROMOCHO PROJECT
THIS IS A COMPUTER GENERATED DRAWING. ALL
000-PI-T-001 PIPING LEGEND P & ID A ISSUED FOR REVIEW MKM JHL JHL 04/29/11 CHANGES HERE TO SHALL BE PERFORMED USING
AREA
CADD ONLY. DRAW N BY: ZDM/MKM DATE : 04/11/11 293-Copper Solvent Extraction C-560 REVISION
000-PI-T-002 INSTRUMENATION LEGEND P & ID B ISSUED FOR CLIENT APPROVAL MKM PT JHL RC 05/03/11 THIS DRAWING IS THE PROPERTY OF AND EMBODIES
PROPRIETARY INFORMATION BELONGING TO AKER TITLE CAD NO.
SOLUTIONS AND MUST BE RETURNED IMMEDIATELY CHECKED BY: JHL DATE : 06/23/11
000-EL-M-001 MECHANICAL EQUIPMENT LIST, REV.U C RE-ISSUED FOR APPROVAL JMR JHL JHL RC 05/10/11 UPON REQUEST. IT MUST NOT BE COPIED IN WHOLE
OR IN PART, NOR THE INFORMATION SHOWN THERE
ON DISCLOSED TO THIRD PARTIES EXCEPT WITH THE
293-FS-T-001 COPPER SX FLOW SHEET 0 ISSUED FOR CONSTRUCTION MKM JHL JHL RC 05/23/11 JHL DATE : 06/23/11 560-293-PI-T-003
WRITTEN PERMISSION. APPROVED BY: COPPER 3
1 UPDATED & RE-ISSUED FOR CONSTRUCTION MKM JHL JHL RC 06/23/11
AUTHORIZED BY: RC DATE : 06/23/11 PLS FEED
UPDATED AND RE-ISSUED FOR CONSTRUCTION. CAC MMB JHL RC 08/26/11 DWG. NO.
2
P & ID
3 UPDATED AND RE-ISSUED FOR CONSTRUCTION. SMF MMB JHL RC 05/02/12
MCP APPROVED: TO DATE : 05/23/11 MINERA CHINALCO PERU S.A. 293-PI-T-003
03-05-2012 8:52:31
NOTES:
293-PI-T-004 293-TK-409 293-AG-409 293-TK-410 293-AG-410 293-TK-411 293-TK-412 293-AG-412 293-TK-413 293-AG-413 293-TK-414 293-TK-406 293-PP-408 293-PP-409 293-SA-042 293-SA-032
E-2 PUMP MIX E-2 PUMP MIX E-2 AUXILIARY E-2 AUXILIARY E-2 SETTLER E-1 PUMP E-1 PUMP E-1 AUXILIARY E-1 AUXILIARY E-1 SETTLER COPPER RAFFINATE COPPER RAFFINATE COPPER RAFFINATE COPPER RAFFINATE E-1 ORGANIC 1. FOR GENERAL NOTES, SEE DRAWING 000-PI-T-001.
TANK TANK AGITATOR MIX TANK MIX TANK TANK MIX TANK MIX TANK MIX TANK MIX TANK TANK TANK PUMP PUMP SAMPLER SAMPLER 2. ORGANIC RECOVERY DISCHARGE TO SETTLER FEED LAUNDER DIP PIPE.
AGITATOR AGITATOR AGITATOR (STANDBY) 3. SEE MECHANICAL DRAWINGS FOR WEIR ACCESS HATCH DETAILS.
FROM ELECTROLYTE
HEAT EXCHANGER TO S-1 PUMP MIX TANK
294-TK-401 293-TK-418
6"-ABS-293-008-S1 6"-ABS-293-008-S1
2851 294-PI-T-001 2849 293-PI-T-005

FROM AQUEOUS RECLAIM PUMP 1"-A-15


293-PP-441
1"-AQA-293-004-S1 (NOTE 2)
2835 293-PI-T-005
LAH
LI
TO SX PLANT
TO SX PLANT 0117 S/D INTERLOCK
CAH S/D INTERLOCK LAL CAH
CI CI CAH CI
LVF1 LVF1 LVF1 LVF1
CI CAH TO SX PLANT
0111 CAL 0112 CAL TO SX PLANT XU 0116 CAL I
XU XU I XU S/D INTERLOCK
I I S/D INTERLOCK 0114 I I
AG409M AG410M CAL AG412M AG413M
LIT
0117 LI LAH LIT
I LCS I LCS LAHH LCS LAHH
LSHH I I LCS 0118 0118 LSHH
LAL
CIT CIT CIT CIT 0115
0113
0111 0112 0114 0116
SAH
SIC SIC SAH SIC SAH SIC SAH LE
1"-ABS-293-009-S1 VFD VFD LE VFD VFD
AG409M SAL AG410M SAL AG412M SAL AG413M SAL 0118
0117 LS LS
FROM STRIP 1 SETTLER TANK CE CE CE CE
293-TK-420 0113 0116 0115
8"-SBO-293-004-S1 0111 0112 0114
2883 293-PI-T-005 293-TK-409 293-TK-410 293-TK-412 293-TK-413
M 293-AG-409 M 293-AG-410 M 293-AG-412 M 293-AG-413
( NOTE 3) (NOTE 3)
INSPECTION PORT INSPECTION PORT INSPECTION PORT INSPECTION PORT

AQ OR AQ OR
3

6"-B-4-GO

8"-B-4-GO

6"-B-4-GO

8"-B-4-GO
4"-A-15

4"-A-15
4"-A-15 293-TK-411 8"-B-4-GO 4"-A-15 293-TK-414

NC

NC
NC NC NC

4"-PSH-293-046-S1

4"-PSH-293-045-S1

6"-ABS-293-004-S1

8"-SXLO-293-032-S1

8"-SXLO-293-030-S1
4"-PSH-293-042-S1
4"-PSH-293-043-S1

6"-PSH-293-041-S1
8"-B-4-GO 6"-B-4-GO 6"-B-4-GO
NC NC NC
8"-B-4-GO
NC
3 2"-A-15
2"-A-15 2"-A-15 2"-A-15 TO LOADED ORGANIC TANK
NC NC NC NC 293-TK-407
8"-SXLO-293-032-S1 8"-SXLO-293-031-S1 8"-SXLO-293-030-S1 8"-SXLO-293-033-S1
2830 293-PI-T-005

1"-A-15 8"x6" 1"-A-15


6"-PSH-293-041-S1 NC 6"-SXLO-293-029-S1
6"-B-4-GO 6"-PSH-293-028-S1 NC
6"-PSH-293-041-S1 NC

FROM COPPER PLS FEED PUMPS 6"-B-4-GO 6"-B-4-GO

2"-PSH-293-049-S1
293-PP-405/406 NC NC 293-SA-032
6"-PSH-293-023-S1 6"-PSH-293-023-S1
2806 293-PI-T-003

FROM COPPER SX 6"-B-4-GO

2"-PSH-293-047-S1

2"-PSH-293-044-S1
SUBMERSIBLE SUMP PUMP NC
293-PP-410
3"-SU-293-074-P7 SAMPLING
2"-PSH-293-048-S1

2909 293-PI-T-001

FROM COPPER PLS


FILTER SLUICE PUMP
293-PP-407
3"-ASLL-293-012-P7
2805 293-PI-T-002

FROM ELECTROLYTE FILTER


294-FL-401/402
6"-LE-293-003-S1
2867 294-PI-T-002

FROM CATHODE WASH TANK E 10"-PD-293-004-S1 E


294-TK-404 10"-PD-293-004-S1 SLOP SLOP

2872 294-PI-T-004
2"-RF-294-021-S1-PP DRAIN DRAIN
6"-ABS-293-004-S1
FROM COPPER ELECTROWINING
SUBMERSIBLE SUMP PUMP
294-PP-480 LSLL S/D
2895 294-PI-T-002
4"-SU-293-020-P7
0019
I
FROM SULFURIC ACID SUMP PUMP
293-PP-450 LIC LAH
2"-ASL-293-001-S1 0119
2937 293-PI-T-006 LAL
LALL

EW CELL SYSTEM SCRUBBER LVF1


RECIRCULATION PUMP FAH
294-PP-415 XU FIC
I I LCS
3078 294-PI-T-004 PP408M 0020 FAL
6"-RF-293-022-L1B

VFD
LIT
3 0119 FIT FE
S1 P7 +

M 0020 0020
3 TO COPPER RAFFINATE
6"-RF-293-031-S1 SEEDING TANK
6"-RF-293-030-S1 285-TK-115
6"x3" 6"x4" 6"x4" 6"-RF-293-034-P7
6"-RF-293-034-P7
3"-A-15 6"x4"
M 2742 285-PI-T-022

6"-C-23 1"-A-15 6"-B-4-GO 4"-A-15A 4"-A-15A


6"-A-15-GO 1"-A-15A
NC 6"-B-4-GO 6"-B-4-GO 1"-A-15 4"-SPH-6A NC NC
TO FLOOR NC 6"-B-4-GO
293-TK-406 6"-B-4-GO 293-PP-408 NC
LVF1
NC 4"-E-18A
XU
I I LCS NC 293-SA-042
PP409M
6"-RF-293-032-S1

6"-RF-293-033-S1

VFD
SAMPLING
M 3 DRAW ING NOT VALID W ITHOUT SIGN AND STAMP OF DOCUMENT CONTROL

6"x3" QUALITY CONTROL

6"x4"
6"-C-23 1"-A-15
1"-A-15 4"-SPH-6A NC DISCIPLINE MANAGER NAME SIGN
DOCUMENT CONTROL
NC 293-PP-409
THIS DRAW ING NOT VALID UNLESS THE LATEST REVISION INITIALS ARE HANDW RITTEN (STANDBY) NAME SIGN AND STAMP

SCALE : PROJECT
REFERENCES REVISIONS REVISIONS NOTICE SHEET SIZE

DWG. NO. TITLE NO. DESCRIPTION BY CHECK APPROVED DATE NO. DESCRIPTION BY CHECK APPROVED DATE
A1 TOROMOCHO PROJECT
THIS IS A COMPUTER GENERATED DRAWING. ALL
000-PI-T-001 PIPING LEGEND P & ID A ISSUED FOR REVIEW MKM JHL JHL 04/29/11 CHANGES HERE TO SHALL BE PERFORMED USING
AREA
CADD ONLY. DRAW N BY: ZDM/MKM DATE : 04/29/11 293-Copper Solvent Extraction C-560 REVISION
000-PI-T-002 INSTRUMENTATION LEGEND P & ID B ISSUED FOR APPROVAL MKM PT JHL RC 05/03/11 THIS DRAWING IS THE PROPERTY OF AND EMBODIES
PROPRIETARY INFORMATION BELONGING TO AKER TITLE CAD NO.
SOLUTIONS AND MUST BE RETURNED IMMEDIATELY CHECKED BY: JHL DATE : 06/23/11
000-EL-M-001 MECHANICAL EQUIPMENT LIST, REV. 1. C RE-ISSUED FOR APPROVAL JMR JHL JHL RC 05/10/11 UPON REQUEST. IT MUST NOT BE COPIED IN WHOLE
OR IN PART, NOR THE INFORMATION SHOWN THERE
ON DISCLOSED TO THIRD PARTIES EXCEPT WITH THE
293-FS-T-002 COPPER SX FLOWSHEET 0 ISSUED FOR CONSTRUCTION MKM JHL JHL RC 05/23/11 JHL DATE : 06/23/11 560-293-PI-T-004
WRITTEN PERMISSION. APPROVED BY: COPPER 3
1 UPDATED & RE-ISSUED FOR CONSTRUCTION MKM JHL JHL RC 06/23/11
AUTHORIZED BY: RC DATE : 06/23/11 EXTRACTION
UPDATED AND RE-ISSUED FOR CONSTRUCTION. CAC MMB JHL RC 08/26/11 DWG. NO.
2
P & ID
3 UPDATED AND RE-ISSUED FOR CONSTRUCTION. SMF MMB JHL RC 05/05/12
MCP APPROVED: TO DATE : 05/23/11 MINERA CHINALCO PERU S.A. 293-PI-T-004
09-05-2012 11:05:53
293-PI-T-005 293-PP-441 293-PP-430 293-PP-431 293-PP-426 293-PP-427 293-TK-407 293-AG-418 293-TK-418 293-AG-419 293-TK-419 293-TK-420 293-SA-033 293-SA-031 NOTES:
COPPER AQUEOUS REAGENT DILUENT COPPER LOADED COPPER LOADED LOADED ORGANIC STRIP 1 PUMP STRIP 1 PUMP STRIP 1 AUXILIARY STRIP 1 AUXILIARY STRIP 1 COPPER SX COPPER SX
RECLAIM PUMP BARREL PUMP BARREL PUMP ORGANIC PUMP ORGANIC PUMP TANK MIX TANK MIX TANK MIX TANK MIX TANK SETTLER TANK STRIPPED ORGANIC STRIP RICH AQUEOUS 1. FOR GENERAL NOTES SEE DRAWING 000-PI-T-001.
2. AQUEOUS ADVANCE INTAKE THROUGH A STAND PIPE IN AQ WEIR.
(STANDBY) AGITATOR AGITATOR SAMPLER SAMPLER
3. VORTEX BREAKER LOCATED IN AQ RECYCLE INTAKE.
4. AQUEOUS RECLAIM DISCHARGE INTO SETTLER FEED LAUNDER.
5. SEE MECHANICAL DETAIL DRAWINGS FOR WEIR ACESS DETAILS.
6. TO BE SPECIFIED BY AKER SOLUTIONS INTERLOCK TABLE,
000-LT-I-205, AT A LATER DATE.

1/2"-S.S. TUBING

LFF1 LFF1
XU XU
1/2"-C-10 1/2"-C-10
PP430M PP431M

1/2"-A-37 I 1/2"-A-37 I
LCS LCS HS
0136

M I M I HV FROM SULFURIC ACID


+

0136 S METERING PUMP


293-PP-447
HIC HIC
VSD VSD 293-PI-T-006 3017
293-PP-430 0130 293-PP-431 0131 FC NOTE: ONLY REQUIRED
FOR COMMISSIONING
TO SX PLANT
S/D INTERLOCK
CAH LVF1 CAH LVF1
CI CI

1/2"-S.S. TUBING
LI LAH TO SX PLANT
0121 XU 0122 XU I
CAL I CAL I S/D INTERLOCK
2"-SXLO-293-005-S1 AG418M AG419M 0123 LAL

1"-SXLO-293-011-S1
REAGENT DILUENT I LCS I LCS LSHH LAHH
LIT
CIT CIT
RO 0123 0136
1"-SXLO-293-010-S1 +
0121 0122 TI TIT
0129
LVF1 0135 0135

2"-SXLO-293-005-S1
SAH SAH

3/4"-C-8A
SIC SIC TAL
VFD VFD
XU AG418M AG419M SAL LE LS
CE SAL CE
PP426M 0123 0136
0121 0122 TE
6"-PD-293-010-P4 S/D 293-AG-418 293-AG-419
I LCS M 293-TK-418 M 293-TK-419 0135 3/4"-A-4
LI LAH LSL I
NC

1"-AQA-293-010-S1
0126 LAL 0126 INSPECTION PORT INSPECTION PORT
S/D VFD
I PSV
3 LIT
1 M OVERFLOW +

0132
TOTE BIN 0126 (NOTE 2)
M (NOTE 3)
AQ OR
FROM E-1 SETTLER TANK 8"-SXLO-293-002-S1
293-TK-414
3 3
2830 293-PI-T-004
8"-SXLO-293-033-S1 6"x3" 8"x6"
3"-A-15

8"-B-4-GO
2"-A-15

6"-A-15-GO
6"-B-4-GO
8"x4" 2"-A-15 293-TK-420

NC
6"-C-23 8"-B-4-GO 8"-B-4-GO NC
8"-B-4-GO 8"-B-4-GO
1"-A-15
4"-SPJ-1H 3 NC
2"-A-15 8"-B-4-GO
2"-AQA-293-008-S1

293-TK-407 8"-B-4-GO NC 293-PP-426 3 1"-A-15 NC 4"-B-4 6"-B-4-GO


NC
6"-A-15
LVF1

1"-SXLO-293-011-S1

8"-SXLO-293-002-S1
8"-SXLO-293-004-S1
8"-SXLO-293-003-S1

LFF1
XU
3 XU

2"-A-15
2"-A-15

6"-RS-293-013-S1
PP427M

NC
PP441M

NC
FROM SX PLANT S/D INTERLOCK S/D
S/D I I LCS
3035 (NOTE 6) I I LCS
(VENDOR FOAM SYSTEM)
PSV
+

0134 1"-AQA-293-010-S1

6"-ABS-293-008-S1
TO E-2 PUMP MIX TANK
VFD 293-TK-409
M

8"-SXLO-293-002-S1
6"-RS-293-014-S1 8"-SBO-293-004-S1
1"-AQA-293-004-S1 PSV 2883 293-PI-T-004
3 +

M 3 0133
3 K
2"x1-1/2"
1"-C-10 1"-A-15 6"x3" 8"x6" FIC FIT
1"-A-15
1-1/2"-SPJ-1H FE
1"-A-15 NC 8"x4" 0128
FAL
0128 +
4"-SBO-293-005-S1
NC 6"-C-23 0128
293-PP-441 1"-A-15 293-SA-033
1"-A-15 4"-SPJ-1H NC
NC
293-PP-427 3
8"-A-15-GO 8"-A-15-GO 8"-B-4-GO
(STANDBY) 1"-A-15A NC SAMPLING
NC

2"-PD-293-013-S1
TO RICH ELECTROLYTE TANK
FROM 293-FIC-0085

2"-PD-293-015-S1
2"-PD-293-016-S1
2"-PD-293-014-S1
293-TK-424
2809 293-PI-T-003 6"-RS-293-013-S1
2850 294-PI-T-001
8"-E-18
NC 6"-B-4-GO
FROM ELECTROLYTE NC
HEAT EXCHANGER
294-HX-401
6"-ABS-293-008-S1
2849 293-PI-T-004

293-SA-031

SAMPLING
T RICH ELECTROLYTE TANK
293-TK-424
10"-PD-293-011-S1 10"-PD-293-011-S1
2825 294-PI-T-001

TO E-2 SETTLER TANK


293-TK-411
1"-AQA-293-004-S1
2835 293-PI-T-004

DRAW ING NOT VALID W ITHOUT SIGN AND STAMP OF DOCUMENT CONTROL

QUALITY CONTROL

DISCIPLINE MANAGER NAME SIGN


DOCUMENT CONTROL

THIS DRAW ING NOT VALID UNLESS THE LATEST REVISION INITIALS ARE HANDW RITTEN NAME SIGN AND STAMP

SCALE : PROJECT
REFERENCES REVISIONS REVISIONS NOTICE SHEET SIZE

DWG. NO. TITLE NO. DESCRIPTION BY CHECK APPROVED DATE NO. DESCRIPTION BY CHECK APPROVED DATE
A1 TOROMOCHO PROJECT
THIS IS A COMPUTER GENERATED DRAWING. ALL
000-P-T-001 PIPING LEGEND P & ID A ISSUED FOR REVIEW MKM JHL JHL 04/29/11 CHANGES HERE TO SHALL BE PERFORMED USING
AREA
CADD ONLY. DRAW N BY: ZDM/MKM DATE : 04/11/11 293-Copper Solvent Extraction C-560 REVISION
000-PI-T002 INSTRUMENTATION LEGEND P & ID B ISSUED FOR CLIENT APPROVAL MKM PT JHL RC 05/03/11 THIS DRAWING IS THE PROPERTY OF AND EMBODIES
PROPRIETARY INFORMATION BELONGING TO AKER TITLE CAD NO.
SOLUTIONS AND MUST BE RETURNED IMMEDIATELY CHECKED BY: JHL DATE : 06/23/11
000-EL-M-001 MECHANICAL LIST, REV.U C RE-ISSUED FOR APPROVAL JMR JHL JHL RC 05/10/11 UPON REQUEST. IT MUST NOT BE COPIED IN WHOLE
OR IN PART, NOR THE INFORMATION SHOWN THERE
293-FS-T-002 COPPER SX FLOWSHEET 0 ISSUED FOR CONSTRUCTION MKM JHL JHL RC 05/23/11 ON DISCLOSED TO THIRD PARTIES EXCEPT WITH THE
JHL DATE : 06/23/11 560-293-PI-T-005
WRITTEN PERMISSION. APPROVED BY: COPPER 3
1 UPDATED & RE-ISSUED FOR CONSTRUCTION MKM JHL JHL RC 06/23/11
AUTHORIZED BY: RC DATE : 06/23/11 LOADED ORGANIC STRIP
UPDATED AND RE-ISSUED FOR CONSTRUCTION. CAC MMB JHL RC 08/26/11 DWG. NO.
2
P & ID
3 UPDATED AND RE-ISSUED FOR CONSTRUCTION. SMF MMB JHL RC 05/07/12
MCP APPROVED: TO DATE : 05/23/11 MINERA CHINALCO PERU S.A. 293-PI-T-005
09-05-2012 11:10:29
293-PP-450 293-TK-427 293-MP-447 1
NOTES:

293-PI-T-006
SULFURIC ACID SULFURIC ACID SULFURIC ACID
1. FOR GENERAL NOTES, SEE DRAWING 000-PI-T-001.
SPILLAGE SUMP PUMP STORAGE TANK METERING PUMP
2. ENTIRE SULFURIC ACID CONTAINMENT SHALL BE LINED WITH
ACID BRICK.

PI
1 0140
FROM PLANT AIR
DISTRIBUTION
1"-PA-265-158-L8B 3"-SAC-293-001-H1
2888 265-PI-T-006
1"-U-1 3"-A-4

VACUUM LE LIT LI LSLL


RELIEF 0141 0141 0141 0141

3"-SAC-293-004-H1
1 TO STRIP 1 AUXILIARY
MIX TANK
FI FQI 293-TK-419
S/D LFF1
0142 0142 3017 293-PI-T-005
XU
LCS I I NOTE: ONLY REQUIRED
PP447M FOR COMMISSIONING.

400 MM MIN.
FIT
FE
+ 0142
M 0142
3/4"-A-4 TO ELECTROWINING CELL
FEED TANK
NC 294-TK-401
1"-SAC-293-003-H1
M 2887 294-PI-T-002

3"-A-15 293-TK-427 1"-A-15 1"-C-8A 1"-A-4


NC 2"-SAC-293-002-H1 2"x1" NC
VENT TO SAFE AREA 2"-A-4 1"-A-15 293-MP-447
NC
1

1
LFF2
XU
I PP450M
LCS
TO COPPER
I RAFFINATE TANK
293-TK-406
LSLL 2"-ASL-293-001-S1 2"-ASL-293-001-S1
2937 293-PI-T-004
f(t) 0143

LI LIT LE 2"-C-23
0143 0143 0143

LAHL 2"-A-15
0143
M 2"-SPH-6A
(NOTE 2)
SULFURIC ACID
CONTAINMENT
293-PP-450

DRAWING NOT VALID WITHOUT SIGN AND STAMP OF DOCUMENT CONTROL

QUALITY CONTROL

DISCIPLINE MANAGER NAME SIGN


DOCUMENT CONTROL

THIS DRAWING NOT VALID UNLESS THE LATEST REVISION INITIALS ARE HANDWRITTEN NAME SIGN AND STAMP

SCALE : PROJECT
REFERENCES REVISIONS REVISIONS NOTICE SHEET SIZE

DWG. NO. TITLE NO. DESCRIPTION BY CHECK APPROVED DATE NO. DESCRIPTION BY CHECK APPROVED DATE
A1 TOROMOCHO PROJECT
THIS IS A COMPUTER GENERATED DRAWING. ALL
000-PI-T-OO1 PIPING LEGEND P & ID A ISSUED FOR REVIEW MKM JHL JHL RC 06/23/11 CHANGES HERE TO SHALL BE PERFORMED USING
AREA
CADD ONLY. DRAWN BY: ZDM DATE : 04/28/11 293-Copper Solvent Extraction C-560 REVISION
000-PI-T-002 INSTRUMENTATION LEGEND P & ID B ISSUED FOR CLIENT APPROVAL MKM JHL JHL RC 06/27/11 THIS DRAWING IS THE PROPERTY OF AND EMBODIES
PROPRIETARY INFORMATION BELONGING TO AKER TITLE CAD NO.
SOLUTIONS AND MUST BE RETURNED IMMEDIATELY CHECKED BY: JHL DATE : 06/30/11
000-EL-M-001 MECHANICAL EQUIPMENT LIST, REVU 0 ISSUED FOR CONSTRUCTION MKM JHL JHL RC 06/30/11 UPON REQUEST. IT MUST NOT BE COPIED IN WHOLE
OR IN PART, NOR THE INFORMATION SHOWN THERE
ON DISCLOSED TO THIRD PARTIES EXCEPT WITH THE
1 UPDATED AND RE-ISSUED FOR CONSTRUCTION. CAC MMB JHL RC 08/26/11 JHL DATE : 06/30/11 293-PI-T-006
WRITTEN PERMISSION. APPROVED BY: SULFURIC 1
AUTHORIZED BY: RC DATE : 06/30/11 ACID
DWG. NO.

MINERA CHINALCO PERU S.A. P & ID


MCP APPROVED: TO DATE : 06/27/11 293-PI-T-006
8/17/2011 11:24:33 AM

You might also like