Descritption Unit Quantit Rate Amount

LEVELLING & FINISHING

Truss Screed with Laser guided Flooring System;-


Levelling & compacting (FM 2 FLOORING) using
Truss Screed Machine & finishing, concrete
surface totolreances of FM 2 Floor as per TR 34
(UK , Technical Report Guidelines), carry out flatness
by using Ride On trowels, bump-cutter and check
rod etc. complete workable RMC at site, in panels of
approved size as per approved drawing and as
directed by the Engineer in charge. Rate inclusive of
making joints & filling with PU sealent as per drawing
complete in all respect

Sqm 12010 175 2101750


Extra for vacuum dewatering the concrete floors
using TREMIX or equivalent over above C-4.1 item
and finishing the top surface to required level/ slope
and grade with rough / polish finish using power
trowels (both fan & disc) of standard make including
curing etc. complete as per specification and
drawing.Rate inclusive of making joints & filling with
PU sealent as per drawing complete in all respect .

Sqm 6390 150 958500


Extra for vacuum dewatering the concrete floors
using TREMIX or equivalent over above C-4.1 item
and finishing the top surface to required level/ slope
and grade with rough / polish finish using power
trowels (both fan & disc) of standard make including
curing etc. complete as per specification and
drawing.Rate inclusive of making joints & filling with
mastic sealing compound as per drawing complete
in all respect .
Sqm 11837 140 1657180
Providing & laying of non metallic FLOOR
HARDNER of SIKKA or equivalent @ 5 kg / sqm to
be laid as per manufacturers spececifications as
directed by Engineer-in-charge

Sqm 16862 85 1433270

Please Note
Includes
Robotic Boom Screed / Truss Setup for Works
Channel Setting as per levels prvoided
Screeding, Vibrating, Compacting, Levelling Floating
& Finishing using ROTs & Tools like Bull Float etc

Diamond Saw Cut Joints


Panel Size Considered 4mby4m
Work in RMC provided in enmarked panels
Doesn’t Includes
Vapour Barrier Installation
Dowel Bar Installation
RMC Doesn’t Have Steel Fiber
Dewatering is Not needed with RMC havin 0.40 wc
ratio
Remarks

Considering
150mm thickness

Considering
150mm thickness

Considering
150mm thickness

Considering
150mm thickness