Doc No.

STRUCTURAL CALCULATIONS (Project No.) - ST-DSR-0001 r1


TCO - Buried Chamber .

FLOATATION .

Ref Docs:
TCO Standard Q-ST-2016 rev 2
"9.15..2 - The factor of safety against floatation shall be a
minimum of 1.1 calculated taking ground water at existing grade ."

Consider Chamber Floatation

Depth of Roof Top below Grade = 0m


Thickness of Roof Slab = 0m
Internal Depth or Depth Below Grade = 2.775 m
Internal Length = 4.3 m
Internal Width = 3.2 m
Base Thickness = 0.7 m
Wall Thickness = 0.4 m

External Volume = 70.89 m3


Internal Volume = 38.18 m3
Concrete volume = 32.71 m3

Concrete Density 24 kN/m3

Chamber Self Weight = 784.9 kN


Floatation Force = 708.9 kN

FoS = 1.11

Floatation FoS is satisfactory

Designed: (Name) Date: XX-XX-XX


Checked: (Name) Sheet 1 of 1.