Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

NOTES

A A B B C C D E D F G H I J
ALL DIMENSIONS ARE IN mm
UNLESS OTHERWISE STATED
DRAWINGS ARE NOT TO BE
6,000 6,000 6,000 6,000 6,000 6,000 6,000 6,000 6,000 SCALED.ALL FIGURED
TENSILE ROOF STRUCTURE TO TENSILE ROOF STRUCTURE TO TENSILE ROOF STRUCTURE TO TENSILE ROOF STRUCTURE TO DIMENSIONS TO BE USED
SPECIALIST DESIGN AND SPECIALIST DESIGN AND SPECIALIST DESIGN AND SPECIALIST DESIGN AND
INSTALATION DETAIL INSTALATION DETAIL INSTALATION DETAIL INSTALATION DETAIL THE CONTRACTOR MUST CHECK
AND VERIFY ALL DIMENSIONS
1 1

STEEL ROOF TRUSS BY ROOFING SPECIALIST

STEEL ROOF TRUSS BY ROOFING SPECIALIST


STEEL ROOF TRUSS BY ROOFING SPECIALIST
STEEL ROOF TRUSS BY ROOFING SPECIALIST
BEFORE COMMENCEMENT
OF ANY WORK
CONSTRUCTION
ALL SLAB AT GROUND LEVEL TO
BE POURED OVER 1000 GAUGE
POLYTHENE SHEET ON 50MM
THICK MURRAM BLINDING
ON HARDCORE
ALL SOIL UNDER SLAB,AROUND
AND UNDER FOUNDATION TO
BE POISONED FOR TERMITE
CONTROL
CIVIL
2 2 ALL SOIL ON CUT EMBANKMENT
TO BE STABILIZED.THE SLOPE
NOT TO EXCEED THE NATURAL
ANGLE OF REPOSE
STRUCTURAL
A B C D E F G H I J ALL BLACK COTTON SOIL TO BE

A B C D REMOVED FROM ALL BUILDINGS


AND PAVED SURFACES
FOR ALL R.C. WORK REFER TO
S.E.'S DETAILS
DEPTH OF FOUNDATION TO BE

ROOF TRUSS LAYOUT SCALE 1:100 DETERMINED ON SITE TO S.E.'S


APPROVAL
ALL WALLS LESS THAN 150MM
THICK TO BE REINFORCED WITH
HOOP IRON AT EVERY ALTERNATE
COURSE
ALL ADJACENT R.C. WORK AND
MASONRY WALLS TO BE TIED
WITH STRIP IRON AT EVERY
ALTERNATE
MECHANICAL
ALL PLUMBING AND DRAINAGE
TO COMPLY WITH RELEVANT
FALL FALL FALL FALL FALL FALL LOCAL AUTHORITY
SVP DENOTES SOIL VENT PIPE
TO BE PROVIDED AT THE END OF
THE DRAINAGE SYSTEM
DRAIN PASS BENEATH
BUILDINGS AND DRIVEWAYS
FALL FALL FALL FALL FALL TO BE ENCASED IN 150MM
CONCRETE SURROUND
STORM DRAIN PIPES TO COMPLY
WITH BS556 SPECIFICATIONS
ALL UNDERGROUND FOUL AND

ROOF PLAN LAYOUT SCALE 1:100 WASTE DRAIN PIPES SHALL BE


uPVC TO COMPLY WITH BS 5255
ALL INSPECTION CHAMBER
TENSILE ROOF STRUCTURE TO COVERS AND FRAMING SHALL

2 SPECIALIST DESIGN AND 1 BE CAST IRON


MINIMUM SLOPE IN THE DRAIN
INSTALATION DETAIL TO SUPPORT PIPES TO BE IN 100
NO CHASES WILL BE ALLOWED
ROOFING MATERIAL FOR PIPES ,SLEEVES WILL BE
ALLOWED WITH WRITTEN
APPROVAL OF STRUCTURAL
ENGINEER.NO CUTTING OF
CONCRETE WITHOUT EXPRESS
RIDGE CAP AND WRITTEN INSTRUCTIONS
FROM THE STRUCTURAL
100x100MM TIE BEAM ENGINEER
ALL TESTING OF PIPES MUST
BE COMPLETED BEFORE
75x50MM PURLINS 50x50MM STRUTS&TIES PLASTERING
ALL MECHANICAL WORKS
COLOURED GCI ROOFING SHEETS MUST BE COORDINATED
WITH ELECTRICAL AND ANY
CONFLICT MUST BE CLARIFIED
BEFORE WORK BEGINS
+8.300 100x50MM RAFTER +8.300 PV DENOTES PERMANENT
VENTILATION

RAIN WATER GUTTER ELECTRICAL


ALL CONDUITS MUST BE LAUD
BEFORE PLASTERING
RAIN WATER DOWN PIPE VALLYVAL LTD.
Street:Popo Street
City:Nairobi
State/Country:Kenya
Postal Code:00100

+6.150 +6.150 JOB TITLE:PROPOSED MINI


STADIUM ON LR. NO. 209/18221,
NAIROBI FOR UNIVERSITY OF
NAIROBI P.O BOX 29288-00100
+5.300 +5.300 NRB
DRAWING TITLE:
ROOF DETAILS
Drawn by Date: 31/5/2012
Valentine Makena Munyua

2 1 Checked by
Drawing Scale 1:100
JOB NO. LL1/2012
Date

Drawing no.007

You might also like