1

Rectangular Insulated Inline Fan


Application : CRIF fresh air fans design gives
opportunity to use them in intake or exhaust air
ventilation systems in the applications where
noise level are more concerned and restricted Equipments India Pvt. Ltd.
space for mounting. For example, it is possible
to place it directly over the counter ceiling in
the premises. It is intended for mounting with
air ducts with diameter of 100, 125, 150, 200,
250 and 315 mm.

Design : Fan casing is made of galvanized steel


sheet insulated with polyurethane foam which
is having good sound absorbing and moisture
resistance features. Connection pipes of
circular section are equipped with rubber seals.

Motor :Two-pole induction motors with


external rotor and impeller with backward
curved blades is used. Motors have built-in heat
protection with automatic restart. Due to the
application of the motor with ball bearings,
with selective lubricating oil the low-noise fan
operating regime, which requires no servicing,
is guaranteed. The motor is mounted on the
rubber isolators inserts in order to reduce Series CRIF
vibrations. Rectangular Insulated Inline Fan
Speed control : Speed control can be achieved
with thyristorcontroller. RPM is changed by
achieved changing voltage. Air quantity
changes according to the change of motor
RPM. Several fans can be connected to one
control device provided that the overall power
and operating current will not exceed the
nominal parameters of the controller.

Mounting : Duct fans are meant for mounting


with round ducts. Fans are mounted in the
blowout of air ducts. In the event of connection
via flexible connectors the fan is necessary to fix Sound and heat isolated centrifugal
to the building construction with the mounts, fans with air flow capacity up to
suspension mounts or holding brackets. Fan 2150 m3/h.
can be mounted in any position taking into
account the air flow direction (it is indicated
with the pointer on the fan case). Free access
for fan servicing is required to attend fan.
2
Rectangular Insulated Inline Fan

Description CRIF - 100 CRIF - 125 CRIF - 150 CRIF - 200 CRIF - 200S CRIF - 250 CRIF - 315

Voltage, V/50Hz 230 230 230 230 230 230 230

Power consumption, W 73 73 72 103 195 198 322

Current, A 0,32 0,32 0,32 0,45 0,85 0,87 1,40

Maximum air consumption, m3/h 240 330 420 730 950 1300 2150

RPM 2560 2590 2600 2560 2590 2600 2600

Noise level at 3m, dBA 33 35 36 38 41 41 43

Maximum temperature of
transferred air, °C -25+55 -25+55 -25+55 -25+50 -25+45 -25+50 -25+45

Index of protection IPX4 IPX4 IPX4 IPX4 IPX4 IPX4 IPX4

Dimensions, mm
Weight,
Type
kg
ØD B B1 H L L1 L2

CRIF - 100 99 322 280 192 447 380 350 5,4

CRIF - 125 124 322 280 192 447 380 350 5,4

CRIF - 150 149 352 310 212 477 410 380 6,4

CRIF - 200 199 432 368 287 588 506 480 10,0

CRIF - 200 S 199 432 368 287 588 506 480 12,0

CRIF - 250 249 432 368 287 588 506 480 12,5

CRIF - 315 314 502 438 397 648 566 540 15,5

Fan Performance Curves


Pressure, P (Pa)

G.A. Drawing 300 CRIF-100

250

200

150

100

50

0
0 50 100 150 200 250
Air flow, (m 3/h)

Sound-power level Octave-frequency band, (Hz)


CRIF - 100 Hz Total 63 125 250 500 1000 2000 4000 8000
L to inlet
WA dBA 59 53 57 54 52 51 54 51 47
LWA to oulet dBA 68 49 50 53 56 66 63 56 54
LWA to environment dBA 40 27 29 32 31 34 29 29 20
Fan Fan
Performance
Performance
Curves
Curves RectangularInsulated
Rectangular Insulated Inline
Inline Fan

3
Pressure, P (Pa) 350 350

Pressure, P (Pa)
CRIF-125 CRIF-150
300 300

250 250

200 200

150 150

100 100

50 50

0 0
0 50 100 150 200 250 300 350 0 50 100 150 200 250 300 350 400 450
3 3
Air flow, (m /h) Air flow, (m /h)

Sound-power level Octave-frequency band, (Hz) Sound-power level Octave-frequency band, (Hz)
CRIF - 125 Hz Total 63 125 250 500 1000 2000 4000 8000 CRIF - 150 Hz Total 63 125 250 500 1000 2000 4000 8000
LWA to inlet dBA 64 51 51 54 56 54 55 53 51 LWA to inlet dBA 62 49 50 58 56 54 55 52 50
LWA to oulet dBA 65 50 49 59 55 61 61 58 51 LWA to oulet dBA 66 43 44 59 55 62 60 55 53
LWA to environment dBA 38 29 32 33 33 33 31 28 25 LWA to environment dBA 41 26 30 35 34 34 30 26 25

400

Pressure, P (Pa)
Pressure, P (Pa)

CRIF-200 500 CRIF-200 S


350

300 400

250
300
200

150 200

100
100
50

0 0
0 100 200 300 400 500 600 700 800 0 200 400 600 800 1000
Air flow, (m 3/h) Air flow, (m 3/h)

Sound-power level Octave-frequency band, (Hz) Sound-power level Octave-frequency band, (Hz)
CRIF - 200 Hz Total 63 125 250 500 1000 2000 4000 8000 CRIF - 200S Hz Total 63 125 250 500 1000 2000 4000 8000
LWA to inlet dBA 52 37 38 45 45 39 39 36 26 LWA to inlet dBA 53 41 43 53 51 47 44 44 36
LWA to oulet dBA 67 49 46 55 64 59 60 53 41 LWA to oulet dBA 70 48 49 57 68 65 63 58 51
LWA to environment dBA 43 33 35 33 38 25 31 25 25 LWA to environment dBA 45 29 32 37 40 27 29 26 27

700
Pressure, P (Pa)

Pressure, P (Pa)

500 CRIF-250 CRIF-315


600

400 500
sales@perfectimpact.net
300 400

300
200
200

100
100

0 0
0 200 400 600 800 1000 1200 1400 0 500 1000 1500 2000
3 3
Air flow, (m /h) Air flow, (m /h)
CARYAIRE reserves the right for technical modifications without notice.

Sound-power level Octave-frequency band, (Hz) Sound-power level Octave-frequency band, (Hz)
CRIF - 250 Hz Total 63 125 250 500 1000 2000 4000 8000 CRIF - 315 Hz Total 63 125 250 500 1000 2000 4000 8000
LWA to inlet dBA 59 44 45 54 51 47 45 45 38 LWA to inlet dBA 59 45 47 56 47 48 50 44 40
LWA to oulet dBA 74 51 51 62 70 67 64 61 55 LWA to oulet dBA 75 52 51 59 68 68 65 62 54
LWA to environment dBA 46 33 36 41 42 30 26 23 27 LWA to environment dBA 48 41 41 44 43 36 28 32 29

Due to continuous improvement in product quality, technical data may change without any prior notice
¬
CA/03/09/2012/700/R2

Head Office : A-10, Sector-59, NOIDA - 201 301 U.P. (India) Tel.: + 91 120 2580553, 54, 55, 56 Fax : + 91 120 2580557
E-mail : sales@caryaire.com, dgupta@caryaire.com WEBSITE : http://www.caryaire.com
Equipments India Pvt. Ltd. MUMBAI Tel. : +91 22 65702056, 65702057 Fax : +91 22 28547314 E-mail : vpdmumbai@caryaire.com
BANGALORE Tel. : +91 80 25727830, 31 Fax : +91 80 25727833 E-mail : salesbangalore@caryaire.com

You might also like