Usa PGPL 2019

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 390

Innovations in Comfort,

Energy Efficiency,
and Safety Solutions
for Buildings

2019
Product Guide and Price List Americas (USD)
Effective April 1, 2019
Small Devices, Big Impact
Since our inception in 1975, Belimo has been focused on delivering
innovative and reliable solutions to the HVAC industry. Our products are
designed to provide buildings with superior levels of comfort, energy
efficiency and safety while minimizing installation and maintenance costs.
Continually driving ongoing improvements related to these five elements
(Comfort, Energy Efficiency, Safety, Installation, and Maintenance) is the
focus of all product developments.

We use the term CESIM to describe these elements.

Our relationships with our customers, partners, shareholders, and


employees are based on trust, performance, and adding value, with a
focus on sustained prosperity rather than short-term gains. We continue
to stay true to our vision with innovative products designed to help our
customers achieve their objectives better, faster and more economically.

Investing in new technology has been key to our success, and Belimo
is proud to highlight the following products:

• Belimo Energy Valves deliver energy efficient operation utilizing


advanced cloud-based analytics to improve building performance
and generate savings.

• Sensors provide seamless integration with other Belimo devices


and Building Automation Systems. Our sensors offer a screw-less
snap cover housing design for quick installation and provide NEMA
4X/IP65 protection.

• Internet of Things (IoT) Actuators offer continuous connectivity


to the cloud and/or to Building Automation Systems.

• Butterfly Valve Assemblies provide intelligent, energy efficient,


and extremely reliable solutions for higher flow applications.

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


These products are simple to set up and enable superior access
to application data using BACnet, Modbus, and Near Field
Communication (NFC) capabilities.

• Belimo ZoneTight™ Zone Valves are designed for maximum

All prices are in US Dollars (USD)


efficiency in tight spaces while consuming up to 95% less energy
than comparable models. Our zero leakage ball valve design is
self-cleaning for long-term worry-free operation.

Thank you for your continued support, and I encourage you to provide
us with any suggestions on improving or expanding our product range
or the quality of service we offer.

Sincerely,

James Furlong
President, BELIMO Americas
Small Devices,
Big Impact

CESIM is the Belimo method to innovate building technology with sensors, valves, and
actuators. As a member of the UN Global Compact, Belimo is an active stakeholder
contributing to the Sustainable Development Goals (SDG) directly. By incorporating the
UN Global Compact principles into strategies, policies, and procedures, Belimo is not only
upholding their basic responsibilities to people and the planet, but also setting the stage
for long-term success of our industry.
CESIM ensures that the “small” Belimo devices have a big impact on Comfort, Energy
Efficiency, Safety, Installation, and Maintenance.

Find out more


belimo.us/cesim
Table of Contents
DAMPER ACTUATORS
NON-FAIL SAFE DAMPER ACTUATORS
PMB Series (1400 in-lbs) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
GMB(X) Series (360 in-lbs) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
AMB Series (180 in-lbs) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
AMX Series (180 in-lbs) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
AHB(X) Linear Series (101 lbf) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
AMQB(X) Series (140 in-lbs) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
AHQB(X) Linear Series (44 lbf) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
NMB(X) Series (90 in-lbs) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
NMQB(X) Quick Running Series (70 in-lbs). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
LMB(X) Series (45 in-lbs) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
LHB Linear Series (34 lbf) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
LHX Linear Series (34 lbf) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
LMQB(X) Quick Running Series (35 in-lbs) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
LHQB(X) Linear Series (22 lbf) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
LUB(X) Series (27 in-lbs) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
CMB Series (18 in-lbs) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Actuator Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
PMB and PKB FAIL-SAFE DAMPER ACTUATORS
PKB Series (1400 in-lbs) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Damper Actuators GKB(X) Series (360 in-lbs) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
EFB Series (270 in-lbs) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Intelligent and Powerful EFX Series (270 in-lbs) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
AFB Series (180 in-lbs) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
AFX Series (180 in-lbs) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
AHKX Series (101 lbf). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
NFB Series (90 in-lbs). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
NFX Series (90 in-lbs). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
NKQB(X) Series (54 in-lbs) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
LF Series (35 in-lbs) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
TFB(X) Series (22 in-lbs) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Actuator Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
FIRE AND SMOKE DAMPER ACTUATORS
FSAF*A Series (180 in-lbs) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
FSAFB Series (180 in-lbs) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
FSNF Series(70 in-lbs) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
FSLF Series (30 in-lbs) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
FSTF Series (18 in-lbs) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Actuator Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
DAMPER ACTUATOR ACCESSORIES
MFT and NFC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Mechanical . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Electronic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48

U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


Specialized Fire and Smoke . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Standard and Customizable Damper Actuation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51

Belimo Energy Valve™ VALVES


ENERGY VALVES
Energy Valve Product Range Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
2-way (½” to 2”) with Non Fail-Safe and Electronic Fail-Safe Actuators . . . . . . . . . . . . . . . . . . . . . . . 64
Solving Low Delta T Leveraging IoT

All prices are in US Dollars (USD)


2-way (2½” to 6”) with Non Fail-Safe and Electronic Fail-Safe Actuators . . . . . . . . . . . . . . . . . . . . . . . 65
2-way (2½” to 6”) ANSI 250 with Non Fail-Safe and Electronic Fail-Safe Actuators . . . . . . . . . . . . . . . . . 66
ELECTRONIC PRESSURE INDEPENDENT CONTROL VALVES (ePIV)
ePIV Product Range Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
(½’’ to 2’’) 2-way with Non Fail-Safe Actuators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72
(2½’’ to 6’’) 2-way with Non Fail-Safe Actuators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73
(½’’ to 2”) 2-way with Fail-Safe Actuators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
(2½’’ to 6’’) 2-way with Fail-Safe Actuators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77
(2½’’ to 6’’) 2-way ANSI Class 250 with Non Fail-Safe and Fail-Safe Actuators . . . . . . . . . . . . . . . . . . . . 79
6-way Electronic Pressure Independent Characterized Control Valve Product Range Overview . . . . . . . . . . . 82
(½’’ to ¾”) 6-way with Non Fail-Safe Actuators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83
ZONETIGHT PRESSURE INDEPENDENT ZONE VALVES (PIQCV)
Pressure Independent Zone Valve (PIQCV) Product Range Overview . . . . . . . . . . . . . . . . . . . . . . . . . 87
(½’’ to ¾”) 2-way with Non Fail-Safe Actuators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
(½’’ to ¾”) 2-way with Fail-Safe Actuators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
ZONETIGHT ZONE VALVES (QCV)
ZoneTight Zone Valve (QCV) Product Range Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97
(½’’ to ¾”) 2-way/3-way with Non Fail-Safe Actuators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
(½’’ to ¾”) 2-way/3-way with Fail-Safe Actuators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 101
6-WAY CHARACTERIZED CONTROL VALVES
6-way Characterized Control Valve Product Range Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
Pressure Independent (½’’ to 1”) 6-way with Non Fail-Safe Actuators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107
ZONE VALVES
Zone Valves Zone Valve Product Range Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111
(½” to 1”) 2-way/3-way with Spring Return Actuators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113
High Performance Solution
All information subject to change. Visit www.belimo.us for the latest version.
Table of Contents
CHARACTERIZED CONTROL VALVES (CCV)
CCV Product Range Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120
Default and MFT Programming Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126
Brass Trim (½” to ¾”) 2-way/3-way with Non Fail-Safe Actuators . . . . . . . . . . . . . . . . . . . . . . . . . 127
Brass Trim (½” to ¾”) 2-way/3-way with Fail-Safe Actuators . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128
Stainless Steel Trim (½” to 3”) 2-way/3-way with Non Fail-Safe Actuators . . . . . . . . . . . . . . . . . . . . . 129
Stainless Steel Trim (½” to 3”) 2-way/3-way with Fail-Safe Actuators . . . . . . . . . . . . . . . . . . . . . . . 133
Stainless Steel Trim (2½” to 6”) 2-way with Non Fail-Safe Return Actuators . . . . . . . . . . . . . . . . . . . . 137
Stainless Steel Trim (2½” to 6”) 2-way with Fail-Safe Actuators . . . . . . . . . . . . . . . . . . . . . . . . . . 138
Stainless Steel Trim (½” to 3”) 2-way/3-way with NEMA 4X Non Fail-Safe Actuators . . . . . . . . . . . . . . . 139
Stainless Steel Trim (1¼” to 3”) 2-way/3-way with NEMA 4X Fail-Safe Actuators . . . . . . . . . . . . . . . . . 141
Stainless Steel Trim (2½” to 6”) 2-way with NEMA 4X Non-Fail and Fail-Safe Actuators . . . . . . . . . . . . . . 142
Stainless Steel (½” to 2”) 2-way/3-way with Quick Running Non Fail-Safe Actuators . . . . . . . . . . . . . . . 144
LR Series Valve Non Fail-Safe Actuators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 146
AR Series Valve Non Fail-Safe Actuators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 147
AKR and AFR Series Fail-Safe Valve Actuators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148
HIGH TEMPERATURE CHARACTERIZED CONTROL VALVES (HTCCV)
HTCCV Product Range Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 151
(½’’ to 1’’) 2-way with Non Fail-Safe Actuators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 154
6-way Pressure (½’’ to 1’’) 2-way with Fail-Safe Actuators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 155
Independent Valve INDUSTRIAL BALL VALVES
Ball Valve Product Range Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 159
Default and MFT Programming Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 163
Energy Efficient Design VS Series (½’’ to 2’’) 2-way with Non Fail-Safe Actuators. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 164
VS Series (½’’ to 2’’) 2-way with Fail-Safe Actuators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 166
L Series (½’’ to 2’’) 3-way with Non Fail-Safe Actuators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 168
L Series (½’’ to 2’’) 3-way with Fail-Safe Actuators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 169
VS Series (½’’ to 2’’) 2-way with NEMA 4X Non Fail-Safe Actuators . . . . . . . . . . . . . . . . . . . . . . . . 170
VSS Series (½’’ to 2’’) 2-way with Non Fail-Safe Actuators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 171
VSS Series (½’’ to 2’’) 2-way with Fail-Safe Actuators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 172
VSS Series (½’’ to 2’’) 2-way with NEMA 4X Non Fail-Safe Actuators . . . . . . . . . . . . . . . . . . . . . . . 173
V BALL VALVES
V Ball Product Range Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 177
VB Series (1” to 6”) 2-way with Non Fail-Safe Actuators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 181
VB Series (1” to 4”) 2-way with Fail-Safe Actuators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 182
GLOBE VALVES
Globe Valve Product Range Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 185
Default and MFT Programming Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 190
Bronze Trim (½” to 2”) 2-way/3-way with Non Fail-Safe Actuators . . . . . . . . . . . . . . . . . . . . . . . . . 191
Bronze Trim (½” to 2”) 2-way/3-way with Electronic Fail-Safe Actuators . . . . . . . . . . . . . . . . . . . . . . 192
ANSI Class VI Stainless Steel Trim (½” to 2”) 2-way with Non Fail-Safe Actuators . . . . . . . . . . . . . . . . . . . . . . . . 193
Leakage Stainless Steel Trim (½” to 2”) 2-way with Electronic Fail-Safe Actuators . . . . . . . . . . . . . . . . . . . . . 194
Bronze Trim / Stainless Steel Trim (½” to 2”) 2-way/3-way with Spring Return Actuators . . . . . . . . . . . . . 195
Bronze Trim (2½” to 6”) 2-way/3-way, ANSI Class 125 with Non Fail-Safe Actuators . . . . . . . . . . . . . . . 197
U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

Bronze Trim (2½” to 6”) 2-way/3-way, ANSI Class 125 with Spring Return and Electronic Fail-Safe Actuators . . 198
Stainless Steel Trim (2½” to 6”) 2-way/3-way, ANSI Class 125 with Non Fail-Safe Actuators . . . . . . . . . . . 200
New Globe Valves Stainless Steel Trim (2½” to 6”) 2-way/3-way, ANSI Class 125 with Spring Return
and Electronic Fail-Safe Actuators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 201
Stainless Steel Trim (2½” to 6”) 2-way, ANSI Class 125 with Non Fail-Safe Actuators . . . . . . . . . . . . . . . 203
Stainless Steel Trim (2½” to 6”) 2-way, ANSI Class 125 with Spring Return and Electronic Fail-Safe Actuators . . 204
Greater Force and Flexibility
All prices are in US Dollars (USD)

Bronze Trim (2½” to 6”) 2-way/3-way, ANSI Class 250 with Non Fail-Safe Actuators . . . . . . . . . . . . . . . 206
Bronze Trim (2½” to 6”) 2-way/3-way, ANSI Class 250 with Spring Return and Electronic Fail-Safe Actuators . . 207
Stainless Steel Trim (2½” to 6”) 2-way/3-way, ANSI Class 250 with Non Fail-Safe Actuators . . . . . . . . . . . 209
Stainless Steel Trim (2½” to 6”) 2-way/3-way, ANSI Class 250 with Spring Return
and Electronic Fail-Safe Actuators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 210
BUTTERFLY VALVES
Butterfly Valve Product Range Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 215
Butterfly Valve Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 218
Butterfly Valve Actuators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 221
Default and MFT Programming Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 224
HD and HDU Series (2’’ to 6’’) 2-way/3-way with Non Fail-Safe Actuators . . . . . . . . . . . . . . . . . . . . . 225
HD Series (2” to 5”) 2-way/3-way with Fail-Safe Actuators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 226
HD, HDU, L Series (3” to 12”) 2-way/3-way with NEMA 4X Non Fail-Safe Actuators . . . . . . . . . . . . . . . . 227
HD, L Series (4’’ to 12’’) 2-way/3-way with NEMA 4X Fail-Safe Actuators . . . . . . . . . . . . . . . . . . . . . 228
HD Series (2’’ to 5’’) 2-way/3-way with NEMA 4X Non Fail-Safe Actuators . . . . . . . . . . . . . . . . . . . . 229
HD Series (2’’ to 5’’) 2-way with NEMA 4X Fail-Safe Actuators . . . . . . . . . . . . . . . . . . . . . . . . . . . 230
HD Series (14’’ to 24’’) 2-way/3-way with NEMA 4X Non Fail-Safe Actuators . . . . . . . . . . . . . . . . . . . 231
Grooved Series (2’’ to 6’’) 2-way/3-way with Non Fail-Safe Actuators . . . . . . . . . . . . . . . . . . . . . . . 233
Grooved Series (2’’ to 6’’) 2-way/3-way with Fail-Safe Actuators . . . . . . . . . . . . . . . . . . . . . . . . . . 234
Grooved Series (2’’ to 12’’) 2-way/3-way with NEMA 4X Non Fail-Safe Actuators . . . . . . . . . . . . . . . . . 235
SHP Series (2’’ to 4’’) 2-way/3-way ANSI Class 150 with Non Fail-Safe Actuators . . . . . . . . . . . . . . . . . 237
SHP Series (2’’ to 6”) 2-way/3-way ANSI Class 150 with Fail-Safe Actuators. . . . . . . . . . . . . . . . . . . . 238
SHP Series (2’’ to 24’’) 2-way/3-way ANSI Class 150 with NEMA 4X Non Fail-Safe Actuators . . . . . . . . . . . 239
SHP Series (2’’ to 4’’) 2-way/3-way ANSI Class 300 with Non Fail-Safe Actuators . . . . . . . . . . . . . . . . . 241
Advanced Butterfly SHP Series (2’’ to 6”) 2-way/3-way ANSI Class 300 with Fail-Safe Actuators. . . . . . . . . . . . . . . . . . . . 242
Valve Assembly SHP Series (2’’ to 16”) 2-way/3-way ANSI Class 300 with NEMA 4X Non Fail-Safe Actuators
Manual Handles and Gear Operators for HD, L, SHP Series . . . . . . . . . . . . . . . . .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
243
245

Intuitive
All information subject to change. Visit www.belimo.us for the latest version.
Table of Contents
PIPE PACKAGES
Component Pricing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 251
For 2-way ePIV and EV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 252
For 2-way PIQCV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 254
For 2-way QCV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 256
For 2-way CCV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 258
For 3-way CCV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260
For Zone Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 262
VALVE ACCESSORIES
Weather Shields . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 266
ePIV Sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 267
Energy Valve Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 268
Battery Backup, Covers, PR/PKR Temperature Sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 269
Temperature Sensors, Replacement Cables, Programming Tools. . . . . . . . . . . . . . . . . . . . . . . . . . 270
Auxiliary Switches & Potentiometers, Extension Bracket, Electric Disconnect, Hand Crank . . . . . . . . . . . . 271
ZoneTight Valve Accessories, Mounting Bracket (6-way CCV), PR/PKR Retrofit Linkages . . . . . . . . . . . . . 272

Sensors SENSORS
Duct / Immersion, Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 275
Duct / Immersion and Duct Averaging, Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 277
Cable and Low Limit Dection, Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 279
Seamless Integration Duct, Temperature/Humidity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 281
Duct, Air Quality. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 283
Duct Switch and Duct Sensor, Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 285
Pipe, Temperature/Condensation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 287
Pipe, Pressure, Differential Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 289
Pipe, Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 291
Outdoor Air, Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 293
Outdoor Air, Temperature/Humidity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 295
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 296
ZIP ECONOMIZER
Selection Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 302
ZIP Economizer Product Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 303
Optional Add-on Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 304
Retrofit Kits and ZIP Packs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 305
Retrofit Solutions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 306

RETROFIT SOLUTIONS
DAMPER ACTUATORS
Replacement of Discontinued Belimo Products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 309
Replacement of Competitor Fire and Smoke Actuators . . . . . . . . . . . . . . . . . . . . . . . . . . . 312
VALVES
Retrofit Solutions How to Select a Globe Valve Retrofit Solution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 316
Retrofit and Replacement, Siemens 599 MT/MZ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 317
Retrofit Linkages for NPT and Flanged Globe Valves with Non Fail-Safe Actuators . . . . . . . . . . . . . 320

U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


Less Down Time, Retrofit Linkages for NPT and Flanged Globe Valves with Fail-Safe Actuators . . . . . . . . . . . . . . . . 321
More Operating Time Globe Valve Retrofit Actuators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Retrofit Components (various manufacturers) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
.
.
.
.
.
.
322
323
Globe Valve Retrofit Solutions - (Honeywell, Johnson Controls, Robertshaw,
Siebe\Invensys\Barber Colman\Schneider, Siemens\Landis\Powers, Warren Controls) . . . . . . . . . . . 324
Custom Globe Valve Retrofit Solutions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 348

All prices are in US Dollars (USD)


Custom Globe Valve Retrofit Solutions Form . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 349
How to Select a Butterfly Valve Retrofit Solution . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 351
Butterfly Valve Retrofit Actuators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 352
Butterfly Valve Retrofit Solutions (Bray, Centerline, Johnson Controls, Keystone, Milwaukee,
Nibco, PDC, Victaulic) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 354
Specialty Retrofit Solutions for Valve Manufacturers (Apollo, Belimo, Challenger, Chemtrol, Dezurik,
Flowseal, FNW, Gruvlok, Hammond, Jamesbury, Jenkins, Metraflex, Mueller, PDC,
Quartermaster, Watts) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 363
Custom Butterfly Valve Retrofit Solutions Form . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 364
Custom Butterfly Valve Retrofit Solutions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 366
Custom Ball Valve Retrofit Solution Form . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 367
Custom Ball Valve Retrofit Solutions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 369
APPENDIX
How to Select a Damper Actuator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 372
Valve Sizing - Water and Steam Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 374
ANSI/FCI Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 383
ZIP Economizer Water Guidelines . . . . . . . . . . . . . . . . . . . . . .
Valve Quotation Form . . . . . . . . . . . . . . . . . . . .
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
384
385
Terms and Conditions of Sale and Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 386
Valve and Actuator Specifications (online at www.belimo.us)
www.belimo.us . . . . . . . . . . . . . . . . . . . . . . . . . . . . 388
Energy Efficient Indoor Air Quality
Platinum Distributors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 389

All information subject to change. Visit www.belimo.us for the latest version.
DAMPER ACTUATORS
DAMPER ACTUATORS
AND ACCESSORIES
Leading Energy Efficiency
• Extensive actuator offering provides high
performance with up to 80% less power
consumption than others.
• Minimum torque guaranteed over the entire
operating range and design life, no loss in
performance due to temperature or supply
voltage.
• Multi-Function Technology (MFT) allows
you to adapt an actuator for replacement
or changes in your system.

Yoraida Dilone, Assembler II, Line Leader


DAMPER ACTUATORS

Making Systems
Transparent

IoT Actuators
Belimo now offers a line of Internet of Things (IoT) damper and valve actuators. These IoT
products include two universal inputs along with BACnet, Modbus and Belimo Cloud
connectivity providing fast and easy commissioning, remote monitoring and the ability to
log in and share system data with your Building Management System. They can seamlessly
integrate with Belimo sensors to measure temperature, pressure, humidity, CO2, VOC’s or
flow to create a more efficient and comfortable environment.

Discover the advantages


www.belimo.us
1
NON FAIL-SAFE
DAMPER ACTUATORS
Versatile Performance
with Low Power Consumption
• Comprehensive torque offering 18 to
1,400 in-lbs with direct coupled, linear, and
rotary actuators.
• Patented brushless DC motor technology
ensuring long reliable operation beyond our
5-year warranty.
• Minimum torque guaranteed over entire
specified operation range.

Michael Bracero, Manager, Market Channel Solutions


Non Fail-Safe Damper Actuator Nomenclature

LM C B 24 -3 -T
Torque Rating Speed Version Power Control Options
PM = 1400 in-lbs Q = Quick B = Basic Required -1 = On/Off -T = Terminal Block .1 =
GM = 360 in-lbs Running X = Customized 24 = 24 VAC/DC, -3 = On/Off, Floating Point Blank = Cable Version Bulk Pack
AM = 180 in-lbs C = Fast 50/60 Hz -3-P5 = On/Off, Floating Point -S = Switch N4 = NEMA 4
NM = 90 in-lbs Running 120 = 100 to w/5 kΩ Feedback
N4X =
LM = 45 in-lbs No Designation 240 VAC, -3-P10 = On/Off, Floating Point
= Normal Speed 50/60 Hz NEMA 4X
CM = 18 in-lbs w/10 kΩ Feedback
(LMB24-3) UP = 24 to -SR = 2-10 VDC N4H =
AH = 101 lbf
LH = 34 lbf 240 VAC* -PC = Phasecut (0-20V) NEMA 4 with
LU = 27 in-lbs -MFT = Multi-Function Technology Heater
-MFT95 = 0 to 135 Ω
-IP = BACnet/IP, Modbus TCP
-MOD = BACnet MS/TP, Modbus
RTU

Note: Q versions have a slightly lower torque rating.


*24 to 125 VDC

Ordering Example

1 Choose the actuator.* LMCB 24 -3 -T 4


Select
connection
type
2 Specify power supply.

3 -T = Terminal
Designate Block
control
24 = 24 VAC/DC

On/Off, Floating Point

5 Complete Ordering Example: LMCB24-3-T

*All functions and packaging are not available with all versions.
NON-SPRING
NON FAIL-SAFE
PMB, GMB(X), Power Power Running Housing Drive Custom
Control Input
Control Input Position Bulk List

RETURN
Supply Consumption Time Type Type Options Feedback Pack Price
and AMB MFT

Optional Accessories:Aux. Switch (S1A, S2A),


Non Fail-Safe

2-10 VDC or 4-20 mA (w/500 Ω Resistor)

2-10 VDC (Default) Adjustable with MFT


Start and Span adj., Start 0.5 to 30 VDC
Damper Actuator

24 to 240 VAC +10%/- 20%, 50/60 Hz

1 SPDT, 3A (0.5A Inductive) @ 250V


24 VAC ± 20%, 50/60 Hz VDC ±10%

Rotary "M", Linear "L", Multi-turn "U"

BACnet: MS/TP or Modbus RTU (1)

Quantity of Actuators in Bulk Pack


PWM adj., 0.02 to 50.0 Seconds
Product Range

Digital (1), Resistive Feedback


Honeywell Series 90, 0-135 Ω

BACnet/IP or Modbus TCP (2)


Wattage Running (Holding)
100 VAC to 240 VAC ±10%

Select Mechanical Coupler


Select Electrical Connection
NEMA 4/4X, (with Heater)

Potentiometer (PxxA GR)


24 to 125 VDC ± 10%

Motor Drive (Default)

Span 2.5 to 32 VDC


0-20v Phasecut
Floating Point

Floating Point
NEMA 1 or 2
VA Rating

On/Off
On/Off
PMB Series PMBUP-3-T ● 23 18 35 4X (H) M ● ● $2,421
1400 in-lbs
[160 Nm] PMBUP-MFT-T ● 19 19 (3.5) 35 4X (H) M ● ● ● 1 ● ● ● $4,639
GMB24-3 ● 6 4.0 (2.0) 150 2 M ● ● ● $551
GMB24-3-T N4 ● 6 4.0 (2.0) 150 4X M ● ● ● $1,251
GMB24-3-T N4H ● 6 4.0 (2.0) 150 4X (H) M ● ● ● $1,751
GMB Series
GMB24-SR ● 6.5 4.5 (2.0) 150 2 M ● ● ● $734
360 in-lbs
[40 Nm] GMB24-SR-T N4 ● 6.5 4.5 (2.0) 150 4X M ● ● ● $1,435
Approx.
GMB24-SR-T N4H ● 6.5 4.5 (2.0) 150 4X (H) M ● ● ● $1,935
90 sq.ft.
GMB24-IP ● 8 5.5 (5) 150 1 M 2 ● 1 ● $843
GM24A-MOD ● 7 4 (1.6) 150 M 1 1 ● $942
GMB24-MFT ● 7 4.0 (1.5) 150 2 M ● ● ● ● ● ● $815
GMX24-3 ● 6 4.0 (2.0) 150 2 M ● ● ● ● ● $551
GMX24-3-T N4 ● 6 4.0 (2.0) 150 4X M ● ● ● ● ● $1,251
GMX24-3-T N4H ● 6 4.0 (2.0) 150 4X (H) M ● ● ● ● ● $1,751
GMX24-SR ● 6.5 4.5 (2.0) 150 2 M ● ● ● ● ● $734
GMX24-SR-T N4 ● 6.5 4.5 (2.0) 150 4X M ● ● ● ● ● $1,435
GMX24-SR-T N4H ● 6.5 4.5 (2.0) 150 4X (H) M ● ● ● ● ● $1,863
Customizable*

GMX Series
360 in-lbs GMX24-PC ● 7 4.0 (1.5) 150 2 M ● ● ● ● ● $885
[40 Nm]
Approx. GMX120-3 ● 7 4.0 (2.0) 150 2 M ● ● ● ● ● $602
90 sq.ft. 75-300
GMX24-MFT ● 7 4.0 (1.5) 2 M ● ● ● ● ● ● ● ● $815
(150)
O16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

75-300
GMX24-MFT-T ● 7 4.0 (1.5) 1 M ● ● ● ● ● ● ● ● $789
(150)
75-300
GMX24-MFT N4 ● 7 4.0 (1.5) 4X M ● ● ● ● ● ● ● ● $1,545
(150)
75-300
GMX24-MFT N4H ● 7 4.0 (1.5) 4X (H) M ● ● ● ● ● ● ● ● $1,973
All prices are in US Dollars (USD)

(150)
AMB24-3 ● 5.5 2.5 (0.5) 95 2 M ● ● ● $389
AMB24-3-T N4 ● 5.5 2.5 (0.5) 95 4X M ● ● ● $708
AMB24-3-T N4H ● 5.5 2.5 (0.5) 95 4X (H) M ● ● ● $1,208
AMB24-3-S ● 5.5 2.5 (0.5) 95 2 M ● ● ● ● $511
AMB24-SR ● 5 2.5 (0.4) 95 2 M ● ● ● $567
AMB Series
AMB24-SR-T ● 5 2.5 (0.4) 95 1 M ● ● ● $539
180 in-lbs
[20 Nm] AMB24-SR-T N4 ● 5 2.5 (0.4) 95 4X M ● ● ● $885
Approx.
AMB24-SR-T N4H ● 5 2.5 (0.4) 95 4X (H) M ● ● ● $1,385
45 sq.ft.
AMB24-IP ● 8 6 (3) 150 1 M 2 ● 1 ● $636
SM24A-MOD ● 6 3.5 (1.4) 150 M 1 1 ● $750
AMB24-MFT ● 6 3.5 (1.3) 150 2 M ● ● ● ● ● ● $613
AMCB24-MFT ● 6 3.5 (1.3) 35 2 M ● ● ● ● ● ● $659
AMB120-3 ● 7 3.0 (0.6) 95 2 M ● ● ● $485

See pages 1-6 through 1-9 for additional generic product series specifications. Visit www.belimo.us for detailed product specifications and downloadable data sheets.
*See pages 4-13 to 4-16 for customization options.

1-1
NON FAIL-SAFE

AMX, AHB(X), Power Power Running Housing Drive Custom


Control Input
Control Input Position Bulk List
Supply Consumption Time Type Type Options Feedback Pack Price
AMQB(X), AHQB(X) MFT

Optional Accessories:Aux. Switch (S1A, S2A),


Non Fail-Safe

2-10 VDC or 4-20 mA (w/500 Ω Resistor)

2-10 VDC (Default) Adjustable with MFT


Start and Span adj., Start 0.5 to 30 VDC
Damper Actuator

24 to 240 VAC +10%/- 20%, 50/60 Hz

1 SPDT, 3A (0.5A Inductive) @ 250V


24 VAC ± 20%, 50/60 Hz VDC ±10%

Rotary "M", Linear "L", Multi-turn "U"

BACnet: MS/TP or Modbus RTU (1)

Quantity of Actuators in Bulk Pack


PWM adj., 0.02 to 50.0 Seconds
Product Range

Digital (1), Resistive Feedback


Honeywell Series 90, 0-135 Ω

BACnet/IP or Modbus TCP (2)


Wattage Running (Holding)
100 VAC to 240 VAC ±10%

Select Mechanical Coupler


Select Electrical Connection
NEMA 4/4X, (with Heater)

Potentiometer (PxxA GR)


24 to 125 VDC ± 10%

Motor Drive (Default)

Span 2.5 to 32 VDC


0-20v Phasecut
Floating Point

Floating Point
NEMA 1 or 2
VA Rating

On/Off
On/Off
AMX24-3 ● 5.5 2.5 (0.5) 95 2 M ● ● ● ● ● $389
AMX24-3-T ● 5.5 2.5 (0.5) 95 1 M ● ● ● ● ● $362
AMX24-3-T N4 ● 5.5 2.5 (0.5) 95 4X M ● ● ● ● ● $708
AMX24-3-T N4H ● 5.5 2.5 (0.5) 95 4X (H) M ● ● ● ● ● $1,208
AMX24-SR ● 5 2.5 (0.4) 95 2 M ● ● ● ● ● $567
AMX24-SR-T ● 5 2.5 (0.4) 95 1 M ● ● ● ● ● $539
AMX24-SR-T N4 ● 5 2.5 (0.4) 95 4X M ● ● ● ● ● $885
AMX24-SR-T N4H ● 5 2.5 (0.4) 95 4X (H) M ● ● ● ● ● $1,385
Customizable*

AMX Series
180 in-lbs AMX24-PC ● 5.5 3.5 (1.3) 90 2 M ● ● ● ● ● $641
[20 Nm]
Approx. AMX120-3 ● 7 3.0 (0.6) 95 2 M ● ● ● ● ● $485
45 sq.ft.
AMX120-SR ● 7.5 4.0 (1.0) 95 2 M ● ● ● ● ● $666
90-300
AMX24-MFT ● 6 3.5 (1.3) 2 M ● ● ● ● ● ● ● ● $613
(150)
90-300
AMX24-MFT N4 ● 6 3.5 (1.3) 4X M ● ● ● ● ● ● ● ● $960
(150)
90-300
AMX24-MFT N4H ● 6 3.5 (1.3) 4X (H) M ● ● ● ● ● ● ● ● $1,460
(150)
35-120
AMCX24-MFT ● 6 3.5 (1.3) 2 M ● ● ● ● ● ● ● ● $659
(35)
75-150
AMX24-MFT95 ● 6 3.5 (1.3) 2 M ● ● ● ● ● $641
(150)

AHB Series AHB24-3-100 ● 4.5 2.0 (0.5) 150 2 L, 4" ● ● $482


101 lbf AHB24-3-200 4.5 2.0 (0.5) 150 2 L, 8" $514

O16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


● ● ●
[450 N Force]
4” or 8” AHB24-SR-100 ● 4.5 2.5 (0.5) 150 2 L, 4" ● ● $667
stroke
AHB24-SR-200 ● 4.5 2.5 (0.5) 150 2 L, 8" ● ● $696
150-450
AHX24-3-100 ● 4.5 2.0 (0.5) 2 L, 4" ● ● ● $482
(150)

All prices are in US Dollars (USD)


150-450
AHX24-3-200 ● 4.5 2.0 (0.5) 2 L, 8" ● ● ● $514
(150)
150-450
AHX24-3-300 ● 4.5 2.0 (0.5) 2 L, 12" ● ● ● $535
(150)
150-450
AHX120-3-100 ● 4.5 2.5 (0.5) 2 L, 4" ● ● ● $519
(150)
150-450
AHX120-3-200 ● 4.5 2.5 (0.5) 2 L, 8" ● ● ● $548
Customizable*

AHX Series (150)


101 lbf
150-450
[450 N Force] AHX120-3-300 ● 4.5 2.5 (0.5) 2 L, 12" ● ● ● $617
(150)
4”, 8”, 12”
stroke 150-450
AHX24-SR-100 ● 4.5 2.5 (0.5) 2 L, 4" ● ● ● $667
(150)
150-450
AHX24-SR-200 ● 4.5 2.5 (0.5) 2 L, 8" ● ● ● $696
(150)
150-450
AHX24-MFT-100 ● 6 3.5 (1.3) 2 L, 4" ● ● ● ● ● ● $687
(150)
150-450
AHX24-MFT-200 ● 6 3.5 (1.3) 2 L, 8" ● ● ● ● ● ● $733
(150)
150-450
AHX24-MFT-300 ● 6 3.5 (1.3) 2 L, 12" ● ● ● ● ● ● $750
(150)
AMQB24-1 ● 26 15 (1.5) 7 2 M ● ● $650
AMQB(X)
140 in-lbs AMQB24-MFT ● 26 15 (1.5) 7 2 M ● ● ● ● $691
[16 Nm]
AMQX24-MFT 26 15 (1.5) 7-15 (7) 2 M $691
C*

● ● ● ● ● ● ●

AHQB24-1-100 ● 23 13 (1.5) 7 2 L, 4" ● $793


AHQB(X)
44 lbf AHQB24-MFT-100 ● 23 13 (1.5) 7 2 L, 4" ● ● ● $848
[200 N Force]
AHQX24-MFT-100 ● 23 13 (1.5) 7-20 (7) 2 L, 4" $848
C*

● ● ● ●

See pages 1-6 through 1-9 for additional generic product series specifications. Visit www.belimo.us for detailed product specifications and downloadable data sheets.
*See pages 4-13 to 4-16 for customization options.
1-2
NON FAIL-SAFE
NMB(X), Power Power Running Housing Drive Custom
Control Input
Control Input Position Bulk List
Supply Consumption Time Type Type Options Feedback Pack Price
NMQB(X) MFT

Optional Accessories:Aux. Switch (S1A, S2A),


Non Fail-Safe

2-10 VDC or 4-20 mA (w/500 Ω Resistor)

2-10 VDC (Default) Adjustable with MFT


Start and Span adj., Start 0.5 to 30 VDC
Damper Actuator

24 to 240 VAC +10%/- 20%, 50/60 Hz

1 SPDT, 3A (0.5A Inductive) @ 250V


24 VAC ± 20%, 50/60 Hz VDC ±10%

Rotary "M", Linear "L", Multi-turn "U"

BACnet: MS/TP or Modbus RTU (1)

Quantity of Actuators in Bulk Pack


PWM adj., 0.02 to 50.0 Seconds
Product Range

Digital (1), Resistive Feedback


Honeywell Series 90, 0-135 Ω

BACnet/IP or Modbus TCP (2)


Wattage Running (Holding)
100 VAC to 240 VAC ±10%

Select Mechanical Coupler


Select Electrical Connection
NEMA 4/4X, (with Heater)

Potentiometer (PxxA GR)


24 to 125 VDC ± 10%

Motor Drive (Default)

Span 2.5 to 32 VDC


0-20v Phasecut
Floating Point

Floating Point
NEMA 1 or 2
VA Rating

On/Off
On/Off
NMB24-3 ● 4 2.0 (0.2) 95 2 M ● ● ● $276
NMB24-3-T N4 ● 4 2.0 (0.2) 95 4X M ● ● ● $597
NMB24-3-T N4H ● 4 2.0 (0.2) 95 4X (H) M ● ● ● $1,097
NMCB24-3 ● 4 2.5 (0.2) 45 2 M ● ● ● $329
NMB24-SR ● 5 2.5 (0.4) 95 2 M ● ● ● $389
NMB Series
90 in-lbs NMB24-SR-T ● 5 2.5 (0.4) 95 1 M ● ● ● $357
[10 Nm]
Approx. 22 NMB24-SR-T N4 ● 5 2.5 (0.4) 95 4X M ● ● ● $708
sq. ft.
NMB24-SR-T N4H ● 5 2.5 (0.4) 95 4X (H) M ● ● ● $1,208
NMCB24-SR ● 5 2.5 (0.4) 45 2 M ● ● ● $445
NMB24-IP ● 6 4 (3) 150 1 M 2 ● 1 ● $533
NM24A-MOD ● 6 3.5 (1.4) 150 M 1 1 ● $617
NMB24-MFT ● 6 3.5 (1.3) 150 2 M ● ● ● ● ● ● ● ● $492
NMX24-3 ● 4 2.0 (0.2) 95 2 M ● ● ● ● ● $276
NMX24-3-T ● 4 2.0 (0.2) 95 1 M ● ● ● ● ● $249
NMX24-3-T N4 ● 4 2.0 (0.2) 95 4X M ● ● ● ● ● $597
NMX24-3-T N4H ● 4 2.0 (0.2) 95 4X (H) M ● ● ● ● ● $1,097
NMX24-SR ● 5 2.5 (0.4) 95 2 M ● ● ● ● ● $389
NMX24-SR-T ● 5 2.5 (0.4) 95 1 M ● ● ● ● ● $357
NMX24-SR-T N4 ● 5 2.5 (0.4) 95 4X M ● ● ● ● ● $708
O16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

Customizable*

NMX Series
NMX24-SR-T N4H ● 5 2.5 (0.4) 95 4X (H) M ● ● ● ● ● $1,208
90 in-lbs
[10 Nm] NMX120-3 ● 5.5 2.5 (0.6) 150 2 M ● ● ● ● ● $321
Approx. 22
sq. ft. NMX120-SR ● 6.5 3.5 (1.0) 150 2 M ● ● ● ● ● $455
45-150
All prices are in US Dollars (USD)

NMX24-MFT ● 6 3.5 (1.3) 2 M ● ● ● ● ● ● ● ● $492


(150)
45-150
NMX24-MFT N4 ● 6 3.5 (1.3) 4X M ● ● ● ● ● ● ● ● $841
(150)
45-150
NMX24-MFT N4H ● 6 3.5 (1.3) 4X (H) M ● ● ● ● ● ● ● ● $1,341
(150)
45-150
NMX24-MFT95 ● 6 3.5 (1.3) 2 M ● ● ● ● ● $572
(150)
20-75
NMCX24-MFT ● 5 3.0 (0.6) 2 M ● ● ● ● ● ● ● ● $577
(45)
NMQB24-1 ● 20 13 (1.5) 4 2 M ● ● $581
NMQB(X)
70 in-lbs NMQB24-MFT ● 20 13 (1.5) 4 2 M ● ● ● ● $634
[8 Nm]
NMQX24-MFT 23 13 (1.5) 4-20 (4) 2 M $634
C*

● ● ● ● ● ● ●

See pages 1-6 through 1-9 for additional generic product series specifications. Visit www.belimo.us for detailed product specifications and downloadable data sheets.
*See pages 4-13 to 4-16 for customization options.

1-3
NON FAIL-SAFE

LMB(X), LHB Power Power Running Housing Drive Custom


Control Input
Control Input Position Bulk List
Supply Consumption Time Type Type Options Feedback Pack Price
Non Fail-Safe MFT

Optional Accessories:Aux. Switch (S1A, S2A),


Damper Actuator

2-10 VDC or 4-20 mA (w/500 Ω Resistor)

2-10 VDC (Default) Adjustable with MFT


Start and Span adj., Start 0.5 to 30 VDC
Product Range

24 to 240 VAC +10%/- 20%, 50/60 Hz

1 SPDT, 3A (0.5A Inductive) @ 250V


24 VAC ± 20%, 50/60 Hz VDC ±10%

Rotary "M", Linear "L", Multi-turn "U"

BACnet: MS/TP or Modbus RTU (1)

Quantity of Actuators in Bulk Pack


PWM adj., 0.02 to 50.0 Seconds

Digital (1), Resistive Feedback


Honeywell Series 90, 0-135 Ω

BACnet/IP or Modbus TCP (2)


Wattage Running (Holding)
100 VAC to 240 VAC ±10%

Select Mechanical Coupler


Select Electrical Connection
NEMA 4/4X, (with Heater)

Potentiometer (PxxA GR)


24 to 125 VDC ± 10%

Motor Drive (Default)

Span 2.5 to 32 VDC


0-20v Phasecut
Floating Point

Floating Point
NEMA 1 or 2
VA Rating

On/Off
On/Off
LMB24-3 ● 2 1.5 (0.2) 95 2 M ● ● ● $196
LMCB24-3 ● 2.5 1.5 (0.2) 35 2 M ● ● ● $242
LMB24-3.1 ● 2 1.5 (0.2) 95 2 M ● ● ● 24 $173
LMB24-3-S ● 2 1.5 (0.2) 95 2 M ● ● ● ● $292
LMB24-3-T ● 2 1.5 (0.2) 95 1 M ● ● ● $169
LMCB24-3-T ● 2.5 1.5 (0.2) 35 1 M ● ● ● $221
LMB24-3-T.1 ● 2 1.5 (0.2) 95 1 M ● ● ● 36 $129
LMB24-3-P5-T ● 2 1.5 (0.2) 95 1 M ● ● 5kΩ ● $292
LMB24-3-P5-T.1 ● 2 1.5 (0.2) 95 1 M ● ● 5kΩ ● 36 $278
LMB24-3-P10-T ● 2 1.5 (0.2) 95 1 M ● ● 10kΩ ● $292
LMB Series
45 in-lbs LMB120-3 ● 4 2.0 (0.5) 150 2 M ● ● ● $248
[5 Nm]
Approx. 11 LMB24-SR ● 3 1.5 (0.4) 95 2 M ● ● ● $313
sq. ft.
LMCB24-SR ● 3 1.5 (0.4) 35 2 M ● ● ● $371
LMB24-SR.1 ● 3 1.5 (0.4) 95 2 M ● ● ● 24 $299
LMB24-SR-T ● 3 1.5 (0.4) 95 1 M ● ● ● $280
LMCB24-SR-T ● 3 1.5 (0.4) 35 1 M ● ● ● $344
LMB24-SR-T.1 ● 3 1.5 (0.4) 95 1 M ● ● ● 36 $261
LMB24-IP ● 4.5 3 (2) 150 1 M 2 ● 1 ● $510
LM24A-MOD ● 5 2.5 (1.3) 150 2 M 1 1 ● $566

O16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


LMB24-MFT ● 5 2.5 (1.2) 150 2 M ● ● ● ● ● ● $413
LMB24-HM ● 2 1.5 (0.2) 95 1 M ● $264
LMB24-10P-HM ● 2 1.5 (0.2) 95 1 M 10kΩ ● $287

All prices are in US Dollars (USD)


LMX24-3 ● 2 1.5 (0.2) 95 2 M ● ● ● ● ● $196
LMX24-3-T ● 2 1.5 (0.2) 95 1 M ● ● ● ● ● $175
LMX24-SR ● 3 1.5 (0.4) 95 2 M ● ● ● ● ● $313
Customizable*

LMX Series
45 in-lbs LMX24-SR-T ● 3 1.5 (0.4) 95 1 M ● ● ● ● ● $283
[5 Nm] LMX120-3 ● 4 2.0 (0.5) 150 2 M ● ● ● ● ● $248
Approx. 11
sq. ft. LMX120-SR ● 4.5 2.5 (1.0) 150 2 M ● ● ● ● ● $383
35-200
LMX24-MFT ● 5 2.5 (1.2) 2 M ● ● ● ● ● ● ● ● $413
(150)
35-150
LMX24-MFT95 ● 5 2.5 (1.2) 2 M ● ● ● ● ● $476
(150)
LHB24-3-100 ● 3 1.5 (0.5) 150 2 L, 4" ● ● $299
LHB Series LHB24-3-T-100 ● 3 1.5 (0.5) 150 2 L, 4" ● ● $285
34 lbf
[150 N Force] LHB24-3-200 ● 3 1.5 (0.5) 300 2 L, 8" ● ● $329
4” or 8”
stroke LHB24-SR-100 ● 3 1.5 (0.5) 150 2 L, 4" ● ● $432
LHB24-SR-200 ● 3 1.5 (0.5) 300 2 L, 8" ● ● $463

See pages 1-6 through 1-9 for additional generic product series specifications. Visit www.belimo.us for detailed product specifications and downloadable data sheets.
*See pages 4-13 to 4-16 for customization options.

1-4
NON FAIL-SAFE
LHX, LMQB(X), Power Power Running Housing Drive Custom
Control Input
Control Input Position Bulk List
Supply Consumption Time Type Type Options Feedback Pack Price
LHQB(X), LUB(X), MFT

Optional Accessories:Aux. Switch (S1A, S2A),


and CMB

2-10 VDC or 4-20 mA (w/500 Ω Resistor)

2-10 VDC (Default) Adjustable with MFT


Start and Span adj., Start 0.5 to 30 VDC
Non Fail-Safe

24 to 240 VAC +10%/- 20%, 50/60 Hz

1 SPDT, 3A (0.5A Inductive) @ 250V


24 VAC ± 20%, 50/60 Hz VDC ±10%

Rotary "M", Linear "L", Multi-turn "U"

BACnet: MS/TP or Modbus RTU (1)

Quantity of Actuators in Bulk Pack


PWM adj., 0.02 to 50.0 Seconds
Damper Actuator

Digital (1), Resistive Feedback


Honeywell Series 90, 0-135 Ω

BACnet/IP or Modbus TCP (2)


Wattage Running (Holding)
100 VAC to 240 VAC ±10%

Select Mechanical Coupler


Select Electrical Connection
NEMA 4/4X, (with Heater)
Product Range

Potentiometer (PxxA GR)


24 to 125 VDC ± 10%

Motor Drive (Default)

Span 2.5 to 32 VDC


0-20v Phasecut
Floating Point

Floating Point
NEMA 1 or 2
VA Rating

On/Off
On/Off
70-270
LHX24-3-100 ● 3 1.5 (0.5) 2 L, 4" ● ● ● $299
(150)
140-540
LHX24-3-200 ● 3 1.5 (0.5) 2 L, 8" ● ● ● $329
(300)
200-810
LHX24-3-300 ● 3 1.5 (0.5) 2 L, 12" ● ● ● $345
(450)
70-270
LHX120-3-100 ● 2.5 1.5 (0.5) 2 L, 4" ● ● ● $334
(150)
140-540
LHX120-3-200 ● 2.5 1.5 (0.5) 2 L, 8" ● ● ● $362
Customizable*

LHX Series (300)


34 lbf
200-810
[150 N Force] LHX120-3-300 ● 2.5 1.5 (0.5) 2 L, 12" ● ● ● $391
(450)
4”, 8”, 12”
stroke 70-270
LHX24-SR-100 ● 3 1.5 (0.5) 2 L, 4" ● ● ● $432
(150)
140-540
LHX24-SR-200 ● 3 1.5 (0.5) 2 L, 8" ● ● ● $463
(300)
70-270
LHX24-MFT-100 ● 5 2.5 (1.2) 2 L, 4" ● ● ● ● ● ● $480
(150)
140-540
LHX24-MFT-200 ● 5 2.5 (1.2) 2 L, 8" ● ● ● ● ● ● $512
(300)
200-810
LHX24-MFT-300 ● 5 2.5 (1.2) 2 L, 12" ● ● ● ● ● ● $540
(450)
LMQB24-1 ● 20 13 (1.5) 2.5 2 M ● ● $497
LMQB(X)
Series LMQB24-MFT ● 20 13 (1.5) 2.5 2 M ● ● ● ● $556
35 in-lbs
[4 Nm] 2.5-10
LMQX24-MFT 20 13 (1.5) 2 M $555
C*

● ● ● ● ● ● ●
(2.5)
O16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

LHQB24-1-100 ● 23 13 (1.5) 3.5 2 L, 4" ● $619


LHQB(X)
22 lbf LHQB24-MFT-100 ● 23 13 (1.5) 3.5 2 L, 4" ● ● ● $699
[100 N
Force] 3.5-15
LHQX24-MFT-100 ● 23 13 (1.5) 2 L, 4" $699
C*

● ● ● ●
(3.5)
All prices are in US Dollars (USD)

LUB Series LUB24-3 ● 2.5 1.0 (0.5) 600 2 U, 360° ● ● $317


27 in-lbs
[3 Nm] LUB24-SR ● 3 3.0 (0.5) 600 2 U, 360° ● ● $434
LUX24-3 ● 2.5 1.0 (0.5) 150 2 U, 360° ● ● ● ● $317
Customizable*

LUX Series
27 in-lbs LUX24-SR ● 3 1.5 (0.5) 150 2 U, 360° ● ● ● ● $434
[3 Nm] 75-150
LUX24-MFT ● 5 2.5 (1.2) 2 U, 360° ● ● ● ● ● ● ● $499
(150)
CMB24-3 ● 1.5 1.0 (0.2) 35 2 M ● ● $195
CMB24-3.1 ● 1.5 1.0 (0.2) 35 2 M ● ● 20 $188

CMB Series CMB120-3 ● 3.5 1.5 (1.0) 35 2 M ● ● $279


18 in-lbs CMB24-3-T ● 1.5 1.0 (0.2) 35 1 M ● ● $170
[2 Nm]
Approx. 4.5 CMB24-3-T.1 ● 1.5 1.0 (0.2) 35 1 M ● ● 20 $140
sq. ft. CMB24-SR-R ● 2.5 1.5 (0.5) 35 2 M ● $313
CMB24-SR-L ● 2.5 1.5 (0.5) 35 2 M ● $313
CHB24-3-T-100.1 ● 1 0.5 (0.2) 380 1 L, 4" ● ● 20 $281

See pages 1-6 through 1-9 for additional generic product series specifications. Visit www.belimo.us for detailed product specifications and downloadable data sheets.
*See pages 4-13 to 4-16 for customization options.

1-5
PMB, GMB, GMX, AMB, AMX Series, NEMA 4/4X Series Housing
NON FAIL-SAFE

Direct Coupled, Non Fail-Safe Damper Actuators

Actuator Specifications

PMB GMB / GMX AMB / AMX


Series Series Series
360 in-lbs 180 in-lbs
1400 in-lbs
[40 Nm] [20 Nm]
[160 Nm]
Approx. 90 sq.ft. Approx. 45 sq.ft.

Angle of rotation 95°, with built-in end stops; Angle of rotation 95°, adjustable with mechanical Angle of rotation 95°, adjustable with mechanical
Max MFT electronically variable 33-100% end stops end stops
Min MFT electronically variable 0-67% MFT electronically variable 0-100% MFT electronically variable 0-100%
Mid MFT electronically variable based on Fits shaft diameter ½” to 1.05” (centers on ¾” shaft Fits shaft diameter ½” to 1.05” (centers on ½” and ¾”
min/max with insert and on 1” without insert) shafts with insert and 1.05” without
Fits shaft diameter 17 mm square interface Position indication reflective visual indicator (snap-on) insert)
Position indication integral pointer in cover Manual override external push-button Position indication reflective visual indicator (snap-on)
Manual override 7 mm hex crank, supplied Direction of rotation external switch Manual override external push-button
Direction of rotation reversible with App Electrical connection 3 ft., 18 GA plenum cable, ½” Direction of rotation external switch
Power Consumption conduit fitting Electrical connection 3 ft., 18 GA plenum rated cable, ½”
24 VAC 19 VA Overload protection electronic throughout rotation conduit fitting; terminal strip (-T)
120 VAC 23 VA models
Auxiliary switch(es) add-on: 1 or 2 SPDT, 3A (0.5A
230 VAC 49 VA inductive) @ 250V adjustable 5° Overload protection electronic throughout rotation
Wattage to 85° Auxiliary switch(es) (-S) models: 1 SPDT, 3A (0.5A
running/holding Housing NEMA 2/IP54, enclosure Type 2 inductive) @ 250V adjustable 5° to
24 VAC 19/3.5 W 85°
120 VAC 18/4 W Agency listings cULus according to UL 60730-1A/-
add-on: 1 or 2 SPDT, 3A (0.5 A
230 VAC 19/6 W 2-14, UL2043, CAN/CSA E60730-
inductive) @ 250V adjustable 5° to 85°
1:02, CE according to 2004/108/EC
Electrical connection terminal block Housing NEMA 2/IP54 (NEMA 1/IP20 for -T
and 2006/95/EC
Overload protection electronic throughout rotation models), enclosure Type 2
Auxiliary switch(es) 2x SPDT 3A resistive (0.5 inductive) Agency listings cULus according to UL 60730-1A/-
@ 24-250V, one set at 10° and one 2-14, UL 2043, CAN/CSA E60730-
field adjustable 0-95° (85° default) 1:02, CE according to 2004/108/EC
and 2006/95/EC
Housing NEMA 4X (IP66/67), UL enclosure
Type 4
Agency listings cULus according to UL 60730-1A/-
2-14, UL2043, CAN/CSA E60730-
1:02, CE according to 2004/108/EC
and 2006/95/EC

 Variable with MFT.

O16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


NEMA 4/4X
Series

All prices are in US Dollars (USD)


Housing

Angle of rotation 95°, adjustable with mechanical


end stops
MFT electronically variable 0-100%
Fits shaft diameter NM, AM- ½” to ¾”
GM- ½” to 1.05”
Manual override push-button (NM and AM only)
Direction of rotation switch (NM and AM only)
Electrical connection terminal strip (-T)
Overload protection electronic throughout rotation
Auxiliary switch(es) add-on: 1 or 2 SPDT, 3A (0.5A
inductive) @ 250V adjustable 5°
to 85°
Housing NEMA 4/4X, IP66/IP67
Agency listings cULus according to UL 60730-
1A/-2-14, CAN/CSA E60730-1:02,
CE according to 2004/108/EC and
2006/95/EC
Control shaft length NM, AM- minimum ¾”
maximum 2¼”
GM- minimum 1”
maximum 3”

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

1-6
AHB, AHX, AMQB, AMQX, AHQB, AHQX Series

NON FAIL-SAFE
Direct Coupled, Non Fail-Safe Damper Actuators

Actuator Specifications

AMQB / AHQB /
AHB / AHX
AMQX AHQX
Series
Series Series
101 lbf
[450 N Force] 44 lbf
140 in-lbs
4”or 8” stroke [200 N Force]
[16 Nm]
4” stroke
Power supply 24 VAC/DC Angle of rotation 95°, adjustable with mechanical Power supply 24 VAC/DC
Manual override external push-button end stops Manual override external push-button
MFT electronically variable 0-100%
Direction of stroke external switch Direction of rotation external switch
Fits shaft diameter ½” to 1.05” (centers on ¾” shafts
Runtime 150 seconds with insert and 1.05” without insert) Runtime 7 seconds
Electrical connection 3 ft., 18 GA plenum cable, ½” Position indication reflective visual indicator (snap-on) Electrical connection 3 ft., 18 GA plenum cable, ½”
conduit fitting Manual override external push-button conduit fitting
Overload protection electronic throughout full stroke Overload protection electronic throughout rotation
Direction of rotation external switch
Auxiliary switch(es) not available Auxiliary switch(es) not available
Runtime 7 seconds
Housing NEMA 2/IP54, enclosure Type 2 Housing NEMA 2/IP54, enclosure Type 2
Electrical connection 3 ft., 18 GA plenum cable, ½”
Agency listings cULus according to UL 60730-1A/- conduit fitting Agency listings cULus according to UL 60730-1A/-
2-14, UL 2043, CAN/CSA E60730- Overload protection electronic throughout rotation 2-14, UL 2043, CAN/CSA E60730-
1:02, CE according to 2004/108/EC 1:02, CE according to 2004/108/EC
and 2006/95/EC Auxiliary switch(es) add-on: 1 or 2 SPDT, 3A (0.5A and 2006/95/EC
inductive) @ 250V adjustable 5°
to 85°
Housing NEMA 2/IP54, enclosure Type 2
Agency listings cULus according to UL 60730-1A/-
2-14, UL2043, CAN/CSA E60730-
1:02, CE according to 2004/108/EC
and 2006/95/EC

 Variable with MFT.


O16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.
All prices are in US Dollars (USD)

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

1-7
NMB, NMX, NMQB, NMQX, LMB, LMX, LHB, LHX Series
NON FAIL-SAFE

Direct Coupled, Non Fail-Safe Damper Actuators

Actuator Specifications

NMB / NMX NMQB / LMB / LMX


Series NMQX Series
90 in-lbs Series 45 in-lbs
[10 Nm] 70 in-lbs [5 Nm]
Approx. 22 sq.ft. [8 Nm] Approx. 11 sq.ft.

Angle of rotation 95°, adjustable with mechanical Angle of rotation 95°, adjustable with mechanical Angle of rotation 95°, adjustable with mechanical
end stops end stops end stops
MFT electronically variable 0-100% MFT electronically variable 0-100% MFT electronically variable 0-100%
Fits shaft diameter ½” to 1.05” (centers on ½” and ¾” Fits shaft diameter ½” to 1.05” (centers on ½” and ¾” Fits shaft diameter ¼” to 5/8” (self-centers on 5/8” shaft)
shafts with insert and 1.05” without shafts with insert and 1.05” without Position indication reflective visual indicator (snap-on)
inserts) insert)
Manual override external push-button
Position indication reflective visual indicator (snap-on) Position indication reflective visual indicator (snap-on)
Direction of rotation external switch
Manual override external push-button Manual override external push-button
Electrical connection 3 ft., 18 GA plenum rated cable, ½”
Direction of rotation external switch Direction of rotation external switch
conduit fitting; terminal strip (-T)
Electrical connection 3 ft., 18 GA plenum rated cable, ½” Runtime 4 seconds models
conduit fitting; terminal strip (-T) Electrical connection 3 ft., 18 GA plenum cable, ½” Overload protection electronic throughout rotation
models conduit fitting Auxiliary switch(es) (-S) Models: 1 SPDT, 3A (0.5A
Overload protection electronic throughout rotation Overload protection electronic throughout rotation inductive) @ 250V adjustable 5°
Auxiliary switch(es) add-on: 1 or 2 SPDT, 3A (0.5A Auxiliary switch(es) add-on: 1 or 2 SPDT, 3A (0.5A to 85°
inductive) @ 250V adjustable 5° inductive) @ 250V adjustable 5° add-on: 1 or 2 SPDT, 3A (0.5A
to 85° to 85° inductive) @ 250V adjustable 5° to 85°
Housing NEMA 2/IP54 (NEMA 1/IP20 for -T Housing NEMA 2/IP54, enclosure Type 2 Housing NEMA 2/IP54 (NEMA 1/IP20 for -T
models), enclosure Type 2 models), enclosure Type 2
Agency listings cULus according to UL 60730-1A/-
Agency listings cULus according to UL 60730-1A/- Agency listings cULus according to UL 60730-1A/-
2-14, UL2043, CAN/CSA E60730-
2-14, UL2043, CAN/CSA E60730- 2-14, UL2043, CAN/CSA E60730-
1:02, CE according to 2004/108/EC
1:02, CE according to 2004/108/EC 1:02, CE according to 2004/108/EC
and 2006/95/EC
and 2006/95/EC and 2006/95/EC

 Variable with MFT.

LHB / LHX
Series

O16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


34 lbf
[150 N Force]
4”or 8” stroke

All prices are in US Dollars (USD)


Power supply 24 VAC/DC
Manual override external push-button
Direction of stroke external switch
Runtime 150 seconds
Electrical connection 3 ft., 18 GA plenum cable, ½”
conduit fitting
Overload protection electronic throughout full stroke
Auxiliary switch(es) not available
Housing NEMA 2/IP54, enclosure Type 2
Agency listings cULus according to UL 60730-1A/-
2-14, UL2043, CAN/CSA E60730-
1:02, CE according to 2004/108/EC
and 2006/95/EC

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

1-8
LMQB, LMQX, LHQB, LHQX, LUB, LUX, CMB Series

NON FAIL-SAFE
Direct Coupled, Non Fail-Safe Damper Actuators

LHQB /
LMQB / LHQX LUB / LUX
LMQX Series Series
Series 22 lbf 27 in-lbs [3 Nm]
35 in-lbs [4 Nm] [100 N Force]
4” stroke
Angle of rotation 95°, adjustable with mechanical Power supply 24 VAC/DC Power supply 24 VAC/DC
end stops Manual override external push-button Manual override external push-button
MFT electronically variable 0-100%
Direction of rotation external switch Angle of rotation endless for -3 models
Fits shaft diameter ½” to 1.05” (centers on ½” and ¾”
Runtime 3.5 seconds 330° for -SR models
shafts with insert and 1.05” without
insert) Fits shaft diameter ⁵₁₆” to ¹³⁄₃₂” [8 to 12 mm] square
Electrical connection 3 ft., 18 GA plenum cable, ½”
Position indication reflective visual indicator (snap-on) conduit fitting Manual override external push-button
Manual override external push-button Overload protection electronic throughout rotation Direction of rotation external switch
Direction of rotation external switch Auxiliary switch(es) not available Runtime 150 seconds
Runtime 2.5 seconds Housing NEMA 2/IP54, enclosure Type 2 Electrical connection 3 ft., 18 GA plenum cable, ½”
Agency listings cULus according to UL 60730-1A/- conduit fitting
Electrical connection 3 ft., 18 GA plenum cable, ½”
conduit fitting 2-14, UL2043, CAN/CSA E60730- Overload protection electronic throughout rotation
Overload protection electronic throughout rotation 1:02, CE according to 2004/108/EC Auxiliary switch not available
and 2006/95/EC
Auxiliary switch(es) add-on: 1 or 2 SPDT, 3A (0.5A Housing NEMA 2/IP54 enclosure Type 2
inductive) @ 250V adjustable 5° Agency listings cULus according to UL 60730-1A/-
to 85° 2-14, UL 2043, CAN/CSA E60730-
Housing NEMA 2/IP54, enclosure Type 2 1:02, CE according to 2004/108/EC
Agency listings cULus according to UL 60730-1A/- and 2006/95/EC
2-14, UL2043, CAN/CSA E60730-
1:02, CE according to 2004/108/EC
and 2006/95/EC

 Variable with MFT.

CMB
Series
O16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

18 in-lbs [2 Nm]
Approx. 4.5 sq.ft.
All prices are in US Dollars (USD)

Angle of rotation limitless without end stops, 315°


with one end stop, 287.5° with two
stops
L = counter clockwise rotation,
R = clockwise rotation
Fits shaft diameter ¼” to ½” (self-centers on 3/8” shaft)
Position indication reflective visual indicator (snap-on)
with magnet
Manual override engages with magnet
magnet built-in to position indicator
Electrical connection 3 ft., 18 GA plenum rated cable
terminal strip (-T) models
Overload protection electronic throughout rotation
Auxiliary switch N/A
Housing NEMA 2/IP54 (NEMA 1/IP20 for -T
models), enclosure Type 2
Agency listings cULus according to UL 60730-1A/-
2-14, UL 2043, CAN/CSA E60730-
1:02, CE according to 2004/108/EC
and 2006/95/EC

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

1-9
Efficiency
Through Training

Belimo University
Belimo University provides comprehensive training in HVAC fundamentals. Our portfolio
includes classroom trainings, online learning modules, webinars, and continuing
education courses for Professional Engineers.
For more information or to schedule training please contact your Belimo sales
representative or visit belimouniversity.com.

Discover the advantages


www.belimouniversity.com

BELIMO
UNIVERSITY
2
FAIL-SAFE
DAMPER ACTUATORS
Reliability and Safety Performance
• Torque, linear, and quick running offerings to
handle challenging applications.
• Patented motor technology with Application
Specific Integrated Circuit reduces energy
consumption and ensures longevity.
• MFT is available giving users the flexibility
to customize and adapt a single actuator to
various controllers and applications.

Chris Jones, Product Manager


Mechanical Fail-Safe Damper Actuator Nomenclature
EF X 24 -MFT -S N4
Torque Rating Speed † Options Power Supply Control -S = Built-in US
Auxiliary N4♦ =
EF = 270 in-lbs C = Fast Running B = Basic 24 = 24 VAC/DC Blank = On/Off
Switch NEMA 4
AF = 180 in-lbs L = Low Noise X = Customized 120 = 120 VAC* -3 = Floating Point
N4X♦ =
NF = 90 in-lbs Blank = Normal Blank = None 230 = 230 VAC -SR = 2-10 VDC
NEMA 4X
LF = 35 in-lbs Speed UP = 24 to 240 VAC** -PC = 0 to 20 Volt
N4H♦ =
TF = 22 in-lbs (Phasecut)
NEMA 4
-ECON-RO3 = 3 kΩ NTC with
Type 10 Heater
Thermistor
Ordering Example -MFT = Multi-Function
5 Technology
1 Choose the actuator.* EFX 24 -MFT -S N4 NEMA 4 option -MFT95 = 0 to 135 Ω
(if available)
-MFT-20 = 6 to 9 VDC,
20 VDC
Specify power supply. 3
2 Power Supply
Designate
control -IP = BACnet/IP, Modbus TCP
4
-MOD = BACnet MS/TP,
Designate -S = Built-in ♦ NEMA 4 option on select models.
24 = 24 VAC/DC MFT (2-10 VDC default) switch Modbus RTU † Only available on certain LF
auxiliary
switch and TF models.
*EF and TF series have 100 to

6 Complete Ordering Example: EFX24-MFT-S N4 240 VAC nominal power supply.


**24 to 125 VDC.

*All functions and options are not available with all versions

Electronic Fail-Safe Damper Actuator Nomenclature


GK B 24 -SR
Torque Rating Speed Version Power Supply Control
PK = 1400 in-lbs Q = Quick Running B = Basic 24 = 24 VAC/DC* -1 = On/Off N4 = NEMA 4
GK = 360 in-lbs Blank = Normal Speed X = Customized UP = 24 to 240 -3 = On/Off, Floating Point N4X♦ = NEMA 4X
NK = 54 in-lbs VAC** -SR = 2-10 VDC N4H = NEMA 4
AHK = 101 lbf -MFT = Multi-Function with Heater
Technology -T = Terminal
-IP = BACnet/IP, Modbus TCP Block
-MOD = BACnet MS/TP, 
Modbus RTU NEMA 4 option on select
models.
Ordering Example *GK...24-3 is 24 VAC only.
**24 to 125 VDC

1 Choose the actuator.* GKB 24 -SR

2 Specify power supply.

3 4 Complete Ordering Example: GKB24-SR


Designate
control *All functions and packaging are not available with all versions.
24 = 24 VAC/DC
2-10 VDC
PKB, GKB(X), Power Power Running Housing Drive Custom
Control Input
Control Input Position List
Supply Consumption Time Type Type Options Feedback Price
EFB Fail-Safe MFT

Optional Accessories: Aux. Switch (S1A, S2A),


Damper Actuator

Start and Span adj., Start 0.5 to 30 VDC (2.0)

SPDT, 3A (0.5A Inductive) @ 250V, (1 or 2)


2-10 VDC or 4-20 mA (w/500 Ω Resistor)

2-10 VDC (Default) Adjustable with MFT


Product Range

24 to 240 VAC +10%/- 20%, 50/60 Hz


24 VAC ± 20%, 50/60 Hz VDC ±10%

BACnet: MS/TP or Modbus RTU (1)


3kΩ (1), 10KΩ (2) NTC Thermistor
Wattage Running/Heater (Holding)

6-9 VDC , 20 VDC Output Voltage

PWM adj., 0.02 to 50.0 Seconds

Digital (1), Resistive Feedback


Honeywell Series 90, 0-135 Ω

BACnet/IP or Modbus TCP (2)


VA Rating (Actuator/Heater)

Select Mechanical Coupler


Select Electrical Connection
NEMA 4/4X, (with Heater)

Span 2.5 to 32 VDC (8.0)

Potentiometer (PxxA GR)

FAIL-SAFE
24 to 125 VDC ± 10%

Motor Drive (Default)

Rotary "M", Linear "L"

0-20v Phasecut
120 VAC ±10%
230 VAC ±10%

Floating Point

Floating Point
NEMA 1 or 2
Fail-Safe

On/Off
On/Off
PKB Series
1400 in-lbs PKBUP-MFT-T ● 49 47 (4) 35 30 2 4X(H) M 1 ● ● ● ● $5,639
[160 Nm]
GKB24-3 ● 21 11 (3) 150 35 2 M ● ● ● $1,280
GKB24-3-T N4H ● 21/21 11/21 (3) 150 35 4X(H) M ● ● ● $2,395
GKB Series GKB24-SR ● 21 11 (3) 150 35 2 M ● ● ● $1,595
360 in-lbs
[40 Nm] GKB24-SR-T N4H ● 21/21 11/21 (3) 150 35 4X(H) M ● ● ● $2,710
Approx. 90
sq. ft. GKB24-IP ● 21 11 (3) 150 35 1 M 2 ● 1 ● $1,766
GKB24-MFT ● 21 11 (3) 150 35 2 M ● ● ● ● ● $1,759
GKB24-MFT-T N4H ● 21/21 11/21 (3) 150 35 4X(H) M ● ● ● ● ● $2,876
GKX24-3 ● 21 11 (3) 150 35 2 M ● ● ● ●3 ● $1,278
GKX24-3-T N4 ● 21/21 11/21 (3) 150 35 4X M ● ● ● ●3 ● $1,895
Customizable*

GKX Series
360 in-lbs GKX24-SR ● 21 11 (3) 150 35 2 M ● ● ● ● ● $1,594
[40 Nm]
Approx. 90 GKX24-SR-T N4 ● 21/21 11/21 (3) 150 35 4X M ● ● ● ● ● $2,210
sq. ft.
GKX24-MFT ● 21 11 (3) 150 35 2 M ● ● ● ● ● ● ● $1,759
GKX24-MFT-T N4 ● 21/21 11/21 (3) 150 35 4X M ● ● ● ● ● ● ● $2,376
EFB24 ● 16 9.5 (4.5) 75 <20 2 M ● $1,001
EFB24 N4 ● 16 9.5 (4.5) 75 <20 4 M ● $1,182
EFB24-S ● 16 9.5 (4.5) 75 <20 2 M ● 2 $1,199
EFB120 ● ● 21 9.5 (4.5) 75 <20 2 M ● $1,114
O16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

EFB120-S ● ● 21 9.5 (4.5) 75 <20 2 M ● 2 $1,317


EFB Series EFB120-S N4 ● ● 21 9.5 (4.5) 75 <20 4 M ● 2 $1,497
270 in-lbs
[30 Nm] EFB24-SR ● 14 8.0 (4.5) 95 <20 2 M ● ● $1,248
All prices are in US Dollars (USD)

EFB24-SR N4 ● 14 8.0 (4.5) 95 <20 2 4 M ● ● $1,428


EFB24-SR-S ● 14 8.0 (4.5) 95 <20 2 M ● ● 2 $1,446
60-150
EFB24-MFT ● 16 9.5 (4.5) <20 2 M ● ● ● ● ● $1,375
(150)
60-150
EFB24-MFT-S ● 16 9.5 (4.5) <20 2 M ● ● ● ● ● 2 $1,573
(150)
3
24 VAC only

See pages 2-7 and 2-8 for additional generic product series specifications. Visit www.belimo.us for detailed product specifications and downloadable data sheets.
*See pages 4-13 to 4-16 for customization options.

2-1
EFX and AFB Power Power
Running Time
Housing Drive Custom
Control Input
Control Input Position List
Supply Consumption Type Type Options Feedback Price
Fail-Safe MFT

Optional Accessories: Aux. Switch (S1A, S2A),


Damper Actuator

Start and Span adj., Start 0.5 to 30 VDC (2.0)

SPDT, 3A (0.5A Inductive) @ 250V, (1 or 2)


2-10 VDC or 4-20 mA (w/500 Ω Resistor)

2-10 VDC (Default) Adjustable with MFT


Product Range
24 to 240 VAC +10%/- 20%, 50/60 Hz
24 VAC ± 20%, 50/60 Hz VDC ±10%

BACnet: MS/TP or Modbus RTU (1)


3kΩ (1), 10KΩ (2) NTC Thermistor
Wattage Running/Heater (Holding)

6-9 VDC , 20 VDC Output Voltage

PWM adj., 0.02 to 50.0 Seconds

Digital (1), Resistive Feedback


Honeywell Series 90, 0-135 Ω

BACnet/IP or Modbus TCP (2)


VA Rating (Actuator/Heater)

Select Mechanical Coupler


Select Electrical Connection
NEMA 4/4X, (with Heater)

Span 2.5 to 32 VDC (8.0)

Potentiometer (PxxA GR)


FAIL-SAFE

24 to 125 VDC ± 10%

Motor Drive (Default)

Rotary "M", Linear "L"

0-20v Phasecut
120 VAC ±10%
230 VAC ±10%

Floating Point

Floating Point
NEMA 1 or 2
Fail-Safe

On/Off
On/Off
EFX24 ● 16 9.5 (4.5) 75 <20 2 M ● ● ● $1,001
EFX24-S ● 16 9.5 (4.5) 75 <20 2 M ● ● ● 2 $1,199
EFX24-S N4 ● 16 9.5 (4.5) 75 <20 4 M ● ● ● 2 $1,381
EFX24-S N4H ● 16 (21) 9.5/21 (4.5) 75 <20 4(H) M ● ● ● 2 $1,520
EFCX24-S N4 ● 16 9.5 (4.5) 75 <10 4 M ● ● ● 2 $1,473
EFX120 ● ● 21 9.5 (4.5) 75 <20 2 M ● ● ● $1,119
EFX120-S ● ● 21 9.5 (4.5) 75 <20 2 M ● ● ● 2 $1,317
EFX120-S N4 ● ● 21 9.5 (4.5) 75 <20 4 M ● ● ● 2 $1,499
EFX120-S N4H ● ● 21/22 9.5/22 (4.5) 75 <20 4(H) M ● ● ● 2 $1,639
Customizable*

EFX
EFCX120-S N4 ● ● 21 9.5 (4.5) 75 <10 4 M ● ● ● 2 $1,591
Series
270 in-lbs EFX24-SR ● 14 8.0 (4.5) 95 <20 2 M ● ● ● ● $1,248
[30 Nm]
EFX24-SR-S ● 14 8.0 (4.5) 95 <20 2 M ● ● ● ● 2 $1,446
EFX24-SR-S N4 ● 14 8.0 (4.5) 95 <20 4 M ● ● ● ● 2 $1,628
EFX24-SR-S N4H ● 14/21 8.0/21 (4.5) 95 <20 4(H) M ● ● ● ● 2 $1,769
EFX120-SR N4 ● ● 21 9.0 (5.5) 95 <20 4 M ● ● ● ● $1,550
EFX120-SR-S N4 ● ● 21 9.0 (5.5) 95 <20 4 M ● ● ● ● 2 $1,746
EFX24-MFT ● 16 9.5 (4.5) 60-150 (150) <20 2 M ● ● ● ● ● ● ● $1,375
EFX24-MFT-S ● 16 9.5 (4.5) 60-150 (150) <20 2 M ● ● ● ● ● ● ● 2 $1,573
EFX24-MFT-S N4 ● 16 9.5 (4.5) 60-150 (150) <20 4 M ● ● ● ● ● ● ● 2 $1,754

O16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


EFX24-MFT-S N4H ● 16/21 9.5/21 (4.5) 60-150 (150) <20 4(H) M ● ● ● ● ● ● ● 2 $1,895
AFB24 ● 7.5 5 (2) <75 <20 2 M ● $559
AFB24 N4H ● 7.5 5 (2) <75 <20 4X(H) M ● $2,360

All prices are in US Dollars (USD)


AFB24-S ● 7.5 5 (2) <75 <20 2 M ● 2 $666
AFB24-S N4H ● 7.5 5 (2) <75 <20 4X(H) M ● 2 $2,468
AFBUP ● 8.5 7 (3.5) <75 <20 2 M ● $623
AFBUP N4H ● 8.5/25 7/25 (3.5) <75 <20 4X(H) M ● $2,427
AFBUP-S ● 8.5 7 (3.5) <75 <20 2 M ● 2 $730
AFBUP-S N4H ● 8.5/25 7/25 (3.5) <75 <20 4X(H) M ● 2 $2,536
AFB24-SR ● 8.5 5.5 (3) 95 <20 2 M ● ● $694
AFB AFB24-SR N4H ● 8.5/25 5.5/25 (3) 95 <20 4X(H) M ● ● $2,499
Series
AFB24-SR-S ● 8.5 5.5 (3) 95 <20 2 M ● ● 2 $801
180 in-lbs
[20 Nm] AFB24-SR-S N4H ● 8.5/25 5.5/25 (3) 95 <20 4X(H) M ● ● 2 $2,608
Approx.
45 sq. ft. AFB24-PC ● 10 7.5 (3) 150 <20 2 M ● ● $870
AFB24-IP ● 13 5.5 (5) 150 <20 1 M 2 ● 1 $790
AKB24-IP ● 21 13 (9) 150 35 1 M 2 ● 1 $848
SF24A-MOD ● 11 8.5 (3.5) 150 <20 M 1 1 $985
AFB24-MFT ● 10 7.5 (3) 70-220 (150) <20 2 M ● ● ● ● ● ● $764
AFB24-MFT N4H ● 10/25 7.5/25 (3) 70-220 (150) <20 4X(H) M ● ● ● ● ● ● $2,571
AFB24-MFT-S ● 10 7.5 (3) 70-220 (150) <20 2 M ● ● ● ● ● ● 2 $871
AFB24-MFT-S N4H ● 10/25 7.5/25 (3) 70-220 (150) <20 4X(H) M ● ● ● ● ● ● 2 $2,680
AFB24-MFT95 ● 10 7.5 (3) 70-220 (150) <20 2 M ● ● $793
AFB24-MFT95 N4H ● 10/25 7.5/25 (3) 70-220 (150) <20 4X(H) M ● ● $2,600

2-2 See pages 2-7 and 2-8 for additional generic product series specifications. Visit www.belimo.us for detailed product specifications and downloadable data sheets.
*See pages 4-13 to 4-16 for customization options.
AFX, AHKX, Power Power Running Housing Drive Custom
Control Input
Control Input Position List
Supply Consumption Time Type Type Options Feedback Price
and NFB MFT

Optional Accessories: Aux. Switch (S1A, S2A),


Fail-Safe

Start and Span adj., Start 0.5 to 30 VDC (2.0)

SPDT, 3A (0.5A Inductive) @ 250V, (1 or 2)


2-10 VDC or 4-20 mA (w/500 Ω Resistor)

2-10 VDC (Default) Adjustable with MFT


Damper Actuator

24 to 240 VAC +10%/- 20%, 50/60 Hz


24 VAC ± 20%, 50/60 Hz VDC ±10%

BACnet: MS/TP or Modbus RTU (1)


3kΩ (1), 10KΩ (2) NTC Thermistor
Wattage Running/Heater (Holding)

6-9 VDC , 20 VDC Output Voltage

PWM adj., 0.02 to 50.0 Seconds


Product Range

Digital (1), Resistive Feedback


Honeywell Series 90, 0-135 Ω

BACnet/IP or Modbus TCP (2)


VA Rating (Actuator/Heater)

Select Mechanical Coupler


Select Electrical Connection
NEMA 4/4X, (with Heater)

Span 2.5 to 32 VDC (8.0)

Potentiometer (PxxA GR)

FAIL-SAFE
24 to 125 VDC ± 10%

Motor Drive (Default)

Rotary "M", Linear "L"

0-20v Phasecut
120 VAC ±10%
230 VAC ±10%

Floating Point

Floating Point
NEMA 1 or 2
Fail-Safe

On/Off
On/Off
AFX24 ● 7.5 5 (2.5) <75 <20 2 M ● ● ● $559
AFX24 N4 ● 7.5 5 (2.5) <75 <20 4X M ● ● ● $1,281
AFX24-S ● 7.5 5 (2.5) <75 <20 2 M ● ● ● 2 $666
AFX24-S N4 ● 7.5 5 (2.5) <75 <20 4X M ● ● ● 2 $1,389
AFXUP ● 8.5 7 (3.5) <75 <20 2 M ● ● ● $623
AFXUP N4 ● 8.5 7 (3.5) <75 <20 4X M ● ● ● $1,348
AFXUP-S ● 8.5 7 (3.5) <75 <20 2 M ● ● ● 2 $730
AFXUP-S N4 ● 8.5 7 (3.5) <75 <20 4X M ● ● ● 2 $1,457
AFX24-SR ● 8.5 5.5 (3) 95 <20 2 M ● ● ● ● $694
Customizable*

AFX Series
180 in-lbs AFX24-SR N4 ● 8.5 5.5 (3) 95 <20 4X M ● ● ● ● $1,420
[20 Nm]
Approx. 45 AFX24-SR-S ● 8.5 5.5 (3) 95 <20 2 M ● ● ● ● 2 $801
sq.ft.
AFX24-SR-S N4 ● 8.5 5.5 (3) 95 <20 4X M ● ● ● ● 2 $1,529
70-220
AFX24-MFT ● 10 7.5 (3) <20 2 M ● ● ● ● ● ● ● ● $764
(150)
70-220
AFX24-MFT N4 ● 10 7.5 (3) <20 4X M ● ● ● ● ● ● ● ● $1,492
(150)
70-220
AFX24-MFT-S ● 10 7.5 (3) <20 2 M ● ● ● ● ● ● ● ● 2 $871
(150)
70-220
AFX24-MFT-S N4 ● 10 7.5 (3) <20 4X M ● ● ● ● ● ● ● ● 2 $1,601
(150)
70-220
AFX24-MFT95 ● 10 7.5 (3) <20 2 M ● ● ● ● $793
(150)
O16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

70-220
AFX24-MFT95 N4 ● 10 7.5 (3) <20 4X M ● ● ● ● $1,521
(150)
AHKX
Series 90-150
AHKX24-MFT-100 22 11 (3) 35 2 L, 4 $1,734
C*

● ● ● ● ● ● ● ●
101 lbf (150)
[450 N]
All prices are in US Dollars (USD)

NFB24 ● 8.5 6 (2.5) <75 <20 2 M ● $456


6/25
NFB24 N4H ● 8.5/25 <75 <20 4X(H) M ● $2,214
(2.5)
NFB24-S ● 8.5 6 (2.5) <75 <20 2 M ● 2 $563
6/25
NFB24-S N4H ● 8.5/25 <75 <20 4X(H) M ● 2 $2,322
(2.5)
NFBUP ● 6.5 6 (2.5) <75 <20 2 M ● $516
6/25
NFBUP N4H ● 6.5/25 <75 <20 4X(H) M ● $2,273
(2.5)
NFBUP-S ● 6.5 6 (2.5) <75 <20 2 M ● 2 $623
NFB Series 6/25
NFBUP-S N4H ● 6.5/25 <75 <20 4X(H) M ● 2 $2,380
90 in-lbs (2.5)
[10 Nm] NFB24-SR ● 6 3.5 (2.5) 95 <20 2 M ● ● $609
Approx. 22
sq.ft. 3.5/25
NFB24-SR N4H ● 6/25 95 <20 4X(H) M ● ● $2,368
(2.5)
NFB24-SR-S ● 6 3.5 (2.5) 95 <20 2 M ● ● 2 $716
3.5/25
NFB24-SR-S N4H ● 6/25 95 <20 4X(H) M ● ● 2 $2,475
(2.5)
40-150
NFB24-MFT ● 9 6.5 (3) <20 2 M ● ● ● ● ● $677
(150)
6.5/25 40-150
NFB24-MFT N4H ● 9/25 <20 4X(H) M ● ● ● ● ● $2,436
(3) (150)
40-150
NFB24-MFT-S ● 9 6.5 (3) <20 2 M ● ● ● ● ● 2 $784
(150)
6.5/25 40-150
NFB24-MFT-S N4H ● 9/25 <20 4X(H) M ● ● ● ● ● 2 $2,543
(3) (150)
See pages 2-7 and 2-8 for additional generic product series specifications. Visit www.belimo.us for detailed product specifications and downloadable data sheets. 2-3
*See pages 4-13 to 4-16 for customization options.
NFX and Power Power Running Housing Drive Custom
Control Input
Control Input Position List
Supply Consumption Time Type Type Options Feedback Price
NKQB(X) MFT

Optional Accessories: Aux. Switch (S1A, S2A),


Fail-Safe

Start and Span adj., Start 0.5 to 30 VDC (2.0)

SPDT, 3A (0.5A Inductive) @ 250V, (1 or 2)


2-10 VDC or 4-20 mA (w/500 Ω Resistor)

2-10 VDC (Default) Adjustable with MFT


Damper Actuator

24 to 240 VAC +10%/- 20%, 50/60 Hz


24 VAC ± 20%, 50/60 Hz VDC ±10%

BACnet: MS/TP or Modbus RTU (1)


3kΩ (1), 10KΩ (2) NTC Thermistor
Wattage Running/Heater (Holding)

6-9 VDC , 20 VDC Output Voltage

PWM adj., 0.02 to 50.0 Seconds


Product Range

Digital (1), Resistive Feedback


Honeywell Series 90, 0-135 Ω

BACnet/IP or Modbus TCP (2)


VA Rating (Actuator/Heater)

Select Mechanical Coupler


Select Electrical Connection
NEMA 4/4X, (with Heater)

Span 2.5 to 32 VDC (8.0)

Potentiometer (PxxA GR)


FAIL-SAFE

24 to 125 VDC ± 10%

Motor Drive (Default)

Rotary "M", Linear "L"

0-20v Phasecut
120 VAC ±10%
230 VAC ±10%

Floating Point

Floating Point
NEMA 1 or 2
Fail-Safe

On/Off
On/Off
NFX24 ● 8.5 6 (2.5) <75 <20 2 M ● ● ● $456
NFX24 N4 ● 8.5 6 (2.5) <75 <20 4X M ● ● ● $1,135
NFX24-S ● 8.5 6 (2.5) <75 <20 2 M ● ● ● 2 $563
NFX24-S N4 ● 8.5 6 (2.5) <75 <20 4X M ● ● ● 2 $1,243
NFXUP ● 6.5 6 (2.5) <75 <20 2 M ● ● ● $516
NFXUP N4 ● 6.5 6 (2.5) <75 <20 4X M ● ● ● $1,194

NFXUP-S ● 6.5 6 (2.5) <75 <20 2 M ● ● ● 2 $623


Customizable*

NFX Series NFXUP-S N4 ● 6.5 6 (2.5) <75 <20 4X M ● ● ● 2 $1,301


90 in-lbs
[10 Nm] NFX24-SR ● 6 3.5 (2.5) 95 <20 2 M ● ● ● ● $609
Approx. 22
sq.ft. NFX24-SR N4 ● 6 3.5 (2.5) 95 <20 4X M ● ● ● ● $1,289
NFX24-SR-S ● 6 3.5 (2.5) 95 <20 2 M ● ● ● ● 2 $716
NFX24-SR-S N4 ● 6 3.5 (2.5) 95 <20 4X M ● ● ● ● 2 $1,396
40-150
NFX24-MFT ● 9 6.5 (3) <20 2 M ● ● ● ● ● ● ● $677
(150)
40-150
NFX24-MFT N4 ● 9 6.5 (3) <20 4X M ● ● ● ● ● ● ● $1,357
(150)
40-150
NFX24-MFT-S ● 9 6.5 (3) <20 2 M ● ● ● ● ● ● ● 2 $784
(150)
40-150
NFX24-MFT-S N4 ● 9 6.5 (3) <20 4X M ● ● ● ● ● ● ● 2 $1,464
(150)
NKQB

O16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


Series NKQB24-1 ● 22 11 (3) 4 4 2 M ● ● $884
54 in-lbs
[6 Nm]
Approx. 12 NKQB24-SR ● 22 11 (3) 4 4 2 M ● ● ● $936
sq.ft.

All prices are in US Dollars (USD)


4,7,10
NKQX24-1 ● 22 11 (3) 4 2 M ● ● ● ● $883
Customizable*

NKQX (4)
Series 4,7,10
NKQX24-SR ● 22 11 (3) 4 2 M ● ● ● ● ● $935
54 in-lbs (4)
[6 Nm] 4,7,10
NKQX24-MFT ● 22 11 (3) 4 2 M ● ● ● ● ● ● ● ● $1,013
(4)
See pages 2-7 and 2-8 for additional generic product series specifications. Visit www.belimo.us for detailed product specifications and downloadable data sheets.
*See pages 4-13 to 4-16 for customization options.

2-4
LF Fail-Safe Power Power Running Housing Drive Custom
Control Input
Control Input Position List
Supply Consumption Time Type Type Options Feedback Price
Damper MFT

Optional Accessories: Aux. Switch (S1A, S2A),


Actuator

Start and Span adj., Start 0.5 to 30 VDC (2.0)

SPDT, 3A (0.5A Inductive) @ 250V, (1 or 2)


2-10 VDC or 4-20 mA (w/500 Ω Resistor)

2-10 VDC (Default) Adjustable with MFT


Product Range

24 to 240 VAC +10%/- 20%, 50/60 Hz


24 VAC ± 20%, 50/60 Hz VDC ±10%

BACnet: MS/TP or Modbus RTU (1)


3kΩ (1), 10KΩ (2) NTC Thermistor
Wattage Running/Heater (Holding)

6-9 VDC , 20 VDC Output Voltage

PWM adj., 0.02 to 50.0 Seconds

Digital (1), Resistive Feedback


Honeywell Series 90, 0-135 Ω

BACnet/IP or Modbus TCP (2)


VA Rating (Actuator/Heater)

Select Mechanical Coupler


Select Electrical Connection
NEMA 4/4X, (with Heater)

Span 2.5 to 32 VDC (8.0)

Potentiometer (PxxA GR)

FAIL-SAFE
24 to 125 VDC ± 10%

Motor Drive (Default)

Rotary "M", Linear "L"

0-20v Phasecut
120 VAC ±10%
230 VAC ±10%

Floating Point

Floating Point
NEMA 1 or 2
Fail-Safe

On/Off
On/Off
LF24 US ● 7 5 (2.5) <40-75 <25 2 M ● $381
LF24-S US ● 7 5 (2.5) <40-75 <25 2 M ● 1 $447
LF120 US ● 7.5 5.5 (3.5) <40-75 <25 2 M ● $422
LF120-S US ● 7.5 5.5 (3.5) <40-75 <25 2 M ● 1 $489
LF230 US ● 7 5 (3) <40-75 <25 2 M ● $520
LF230-S US ● 7 5 (3) <40-75 <25 2 M ● 1 $587
LF24-SR US ● 5 2.5 (1) 150 <25 2 M ● ● $520
LF24-SR-S US ● 5 2.5 (1) 150 <25 2 M ● ● 1 $587

LF Series LF24-SR-E US ● 5 2.5 (1) 150 <25 2 M ● ● $562


35 in-lbs LF24-3 US ● 5 2.5 (1) 150 <25 2 M ● ● $463
[4 Nm]
Approx. LF24-3-S US ● 5 2.5 (1) 150 <25 2 M ● ● 1 $530
8.5 sq.ft.
LF24-ECON-R03 US ● 5 2.5 (1) 95 <25 2 M 1 ● $591
LF24-ECON-R10 US ● 5 2.5 (1) 95 <25 2 M 2 ● $591
75-300
LF24-MFT US ● 5 2.5 (1) <25 2 M ● ● ● ● ● $591
(150)
75-300
LF24-MFT-S US ● 5 2.5 (1) <25 2 M ● ● ● ● ● 1 $658
(150)
LF24-MFT-20 US ● 6 3.5 (1.5) 150 <25 2 M ● ● ● ● ● ● $656
LF24-MFT-S-20 US ● 6 3.5 (1.5) 150 <25 2 M ● ● ● ● ● ● 1 $723
LFC24-3-R US ● 5 2.5 (1) 90 <25 2 M ● $526
O16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

LFC24-3-S US ● 5 2.5 (1) 90 <25 2 M ● 1 $591

See pages 2-7 and 2-8 for additional generic product series specifications. Visit www.belimo.us for detailed product specifications and downloadable data sheets.
All prices are in US Dollars (USD)

2-5
TFB(X) Fail-Safe Power Power Running Housing Drive Custom
Control Input
Control Input Position List
Supply Consumption Time Type Type Options Feedback Price
Damper Actuator MFT

Optional Accessories: Aux. Switch (S1A, S2A),


Product Range

Start and Span adj., Start 0.5 to 30 VDC (2.0)

SPDT, 3A (0.5A Inductive) @ 250V, (1 or 2)


2-10 VDC or 4-20 mA (w/500 Ω Resistor)

2-10 VDC (Default) Adjustable with MFT


24 to 240 VAC +10%/- 20%, 50/60 Hz
24 VAC ± 20%, 50/60 Hz VDC ±10%

BACnet: MS/TP or Modbus RTU (1)


3kΩ (1), 10KΩ (2) NTC Thermistor
Wattage Running/Heater (Holding)

6-9 VDC , 20 VDC Output Voltage

PWM adj., 0.02 to 50.0 Seconds

Digital (1), Resistive Feedback


Honeywell Series 90, 0-135 Ω

BACnet/IP or Modbus TCP (2)


VA Rating (Actuator/Heater)

Select Mechanical Coupler


Select Electrical Connection
NEMA 4/4X, (with Heater)

Span 2.5 to 32 VDC (8.0)

Potentiometer (PxxA GR)


FAIL-SAFE

24 to 125 VDC ± 10%

Motor Drive (Default)

Rotary "M", Linear "L"

0-20v Phasecut
120 VAC ±10%
230 VAC ±10%

Floating Point

Floating Point
NEMA 1 or 2
Fail-Safe

On/Off
On/Off
TFB24 ● 5 2 (1.3) <75 <25 2 M ● $310
TFB24-S ● 5 2 (1.3) <75 <25 2 M ● 1 $376
TFLB24 ● 5 2 (1.3) <75 <75 2 M ● $311
TFB120 ● ● 5 2.5 (1.3) <75 <25 2 M ● $362
TFB120-S ● ● 5 2.5 (1.3) <75 <25 2 M ● 1 $427
TFLB120 ● ● 5 2.5 (1.3) <75 <75 2 M ● $363
TFB Series
22 in-lbs TFCB120-S ● ● 6 3 (1.5) <30 <25 2 M ● 1 $451
[2 Nm] TFB24-SR ● 4 2 (1) 95 <25 2 M ● ● $442
Approx. 5.5
sq.ft. TFB24SR-S ● 4 2 (1) 95 <25 2 M ● ● 1 $508
TFB120-SR ● ● 5.5 2.5 (2) 95 <25 2 M ● ● $493
TFB24-3 ● 4 2.5 (1) 95 <25 2 M ● ● $404
TFB24-3-S ● 4 2.5 (1) 95 <25 2 M ● ● 1 $469
75-300
TFB24-MFT ● 4 2.5 (1) <25 2 M ● ● ● ● ● $512
(150)
75-300
TFB24-MFT-S ● 4 2.5 (1) <25 2 M ● ● ● ● ● 1 $578
(150)
TFX24 ● 5 2 (1.3) <75 <25 2 M ● ● ● $310
TFX24-S ● 5 2 (1.3) <75 <25 2 M ● ● ● 1 $376
TFX120 ● ● 5 2.5 (1.3) <75 <25 2 M ● ● ● $362
TFX120-S ● ● 5 2.5 (1.3) <75 <25 2 M ● ● ● 1 $427

O16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


TFCX120-S ● ● 6 3 (1.5) <30 <25 2 M ● ● ● $451
Customizable*

TFX Series
22 in-lbs TFX24-SR ● 4 2 (1) 95 <25 2 M ● ● ● ● $442
[2 Nm]
Approx. 5.5 TFX24-SR-S ● 4 2 (1) 95 <25 2 M ● ● ● ● 1 $508
sq.ft.
TFX24-3 ● 4 2.5 (1) 95 <25 2 M ● ● ● ● $404

All prices are in US Dollars (USD)


TFX24-3-S ● 4 2.5 (1) 95 <25 2 M ● ● ● ● 1 $469
75-300
TFX24-MFT ● 4 2.5 (1) <25 2 M ● ● ● ● ● ● ● $512
(150)
75-300
TFX24-MFT-S ● 4 2.5 (1) <25 2 M ● ● ● ● ● ● ● 1 $578
(150)
See pages 2-7 and 2-8 for additional generic product series specifications. Visit www.belimo.us for detailed product specifications and downloadable data sheets.
*See pages 4-13 to 4-16 for customization options.

2-6
PKB, GKB, GKX, EFB, EFX, AFB, AFX, AHKX Series
Direct Coupled, Fail-Safe Damper Actuators

Actuator Specifications

PKB GKB / GKX EFB / EFX


Series Series Series
1400 in-lbs 360 in-lbs [40 Nm] 270 in-lbs [30 Nm]

FAIL-SAFE
[160 Nm] Approx. 90 sq.ft. Approx. 66 sq.ft.

Angle of rotation 95°, with built-in end stops; Angle of rotation 95°, adjustable with mechanical Angle of rotation 95°, adjustable with mechanical
Max MFT electronically variable 33-100% end stops end stops
Min MFT electronically variable 0-67% MFT electronically variable 0-100% MFT electronically variable 0-100%
Mid MFT electronically variable based on Fits shaft diameter ½” to 1.05” (center on ¾” shaft with Fits shaft diameter ½” to 1.05” (clamp centers on ¾”
min/max insert and on 1” without insert) and 1.05”)
Fits shaft diameter 17 mm square interface (custom Position indication reflective visual indicator (snap on) Position indication visual indicator
coupler may be required)
Manual override external push button Manual override 5 mm hex crank (3/16” allen),
Position indication integral pointer in cover supplied
Direction of rotation external switch
Manual override 7 mm hex crank, supplied Direction of rotation external switch with -SR and MFT
Fail-safe setting
Direction of rotation reversible with App -3, -SR 0°-95° at 10° intervals Spring return CW/CCW mounting (reversible)
Power Consumption MFT 0-100% at 10% intervals Electrical connection 3 ft., 18 GA appliance cable, ½”
24 VAC 49 VA Electrical connection 3 ft., 18 GA plenum rated cable, ½” conduit fitting (default)
120 VAC 43 VA conduit fitting Overload protection electronic throughout rotation
230 VAC 66 VA Overload protection electronic throughout rotation Ambient temperature -22°F to +122°F [-30°C to +50°C]
Wattage
Ambient temperature -22°F to +122°F [-30°C to +50°C] N4H models:
running/holding
Auxiliary switch(es) add on: 1 or 2 SPDT, 3A (0.5A -40°F to +122°F [-40°C to +50°C]
24 VAC 47/4 W
120 VAC 40/8 W inductive) @ 250V adjustable 5° Auxiliary switch(es) (-S) NEMA 2 models: 2 SPDT, 3A
230 VAC 38/6 W to 85° (0.5A inductive) @ 250V, one switch
Housing NEMA 2, IP54, UL enclosure Type 2 fixed at 10°, one adjustable 10°
Fail-safe setting adjustable with App
to 85°
Electrical connection terminal block Agency listings cULus according to UL 60730-1A/-
Housing NEMA 2/IP54, UL enclosure Type 2
2-14, UL 2043, CAN/CSA E60730-
Overload protection electronic throughout rotation N4, N4H models: NEMA 4/IP66,
1:02, CE according to 2004/108/EC
Auxiliary switch(es)2x SPDT 3A resistive (0.5 inductive) Enclosure Type 4
and 2006/95/EC
@ 24-250 VAC, one set at 10° and Agency listings cULus according to UL 60730-1A/-
one field adjustable 0-95° (85° 2-14, UL 2043, CAN/CSA E60730-
default) 1:02, CE according to 2004/108/EC
Ambient temperature -22°F to +122°F [-30°C to +50°C] and 2006/95/EC
Housing NEMA 4X, IP66/67, UL enclosure  Variable with MFT.
Type 4
Agency listings cULus according to UL 60730-1A/-
2-14, UL 2043, CAN/CSA E60730-
1:02, CE according to 2004/108/EC
O16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

and 2006/95/EC

AFB / AFX AHKX


Series Series
180 in-lbs [20 Nm] 101 lbf
All prices are in US Dollars (USD)

Approx. 45 sq.ft. [450 N force]

Angle of rotation 95°, adjustable with mechanical Linear stroke 4” [100 mm]
end stops Manual override external push button
MFT electronically variable 0-100%
Direction of stroke reversible with switch
Fits shaft diameter ½” to 1.05” (clamp centers on ½”,
¾”, and 1.05”) Fail-safe setting 0-100% at 10% intervals
Position indication visual indicator Electrical connection
3 ft., 18 GA plenum rated cable, ½”
Manual override 5 mm hex crank (3/16” allen), conduit fitting
supplied Ambient temperature -22°F to +122°F [-30°C to +50°C]
Direction of rotation external switch with -SR and MFT Overload protection electronic throughout full stroke
Spring return CW/CCW mounting (reversible) Housing NEMA 2, IP54, UL enclosure Type 2
Electrical connection 3 ft., 18 GA appliance cable, ½” Agency listings cULus according to UL 60730-1A/-
conduit fitting (default) 2-14, UL 2043, CAN/CSA E60730-
Overload protection electronic throughout rotation 1:02, CE according to 2004/108/EC
and 2006/95/EC
Ambient temperature -22°F to +122°F [-30°C to +50°C]
Auxiliary switch(es) (-S) models: 2 SPDT, 3A (0.5A
inductive) @ 250V, one switch fixed
at 10°, one adjustable 10° to 90°
Housing NEMA 2/IP54, UL enclosure Type 2
Agency listings cULus according to UL 60730-1A/-
2-14, UL 2043, CAN/CSA E60730-
1:02, CE according to 2004/108/EC
and 2006/95/EC

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

2-7
NFB, NFX, NKQB, NKQX LF, TFB, TFX Series
Direct Coupled, Fail-Safe Damper Actuators

Actuator Specifications

NKQB /
NFB / NFX LF
NKQX
Series Series
Series
90 in-lbs [10 Nm] 35 in-lbs [4 Nm]
54 in-lbs [6 Nm]
FAIL-SAFE

Approx. 22 sq.ft. Approx. 8.5 sq. ft.


Approx. 12 sq.ft.

Angle of rotation 95°, adjustable with mechanical Angle of rotation 95°, adjustable with mechanical end Angle of rotation 95°, adjustable with mechanical
end stops stops. MFT electronically variable 0-100% end stops
MFT electronically variable 0-100% Fits shaft diameter ½” to 1.05” (center on ½” and ¾” MFT electronically variable 0-100%
Fits shaft diameter ½” to 1.05” (clamp centers on ½”, shaft with insert and on 1” without Fits shaft diameter 3/ ”-½” standard (centers on ½”);
8
¾”, and 1.05”) insert) ½”-¾” with K6-1 clamp accessory
Position indication visual indicator Position indication reflective visual indicator (snap on) Position indication visual indicator
Manual override 5 mm hex crank (3/16” allen), Manual override external push button Direction of rotation CW/CCW external switch
supplied Direction of rotation external switch (proportional models)
Direction of rotation external switch with -SR and MFT Spring return CW/CCW mounting
Fail-safe setting
Spring return CW/CCW mounting (reversible) reversible
-1, -SR 0°-95° at 10° intervals
MFT 0-100% at 10% intervals Electrical connection 3 ft., 18 GA plenum cable
Electrical connection 3 ft., 18 GA appliance cable, ½”
(modulating), 3 ft., 18 GA appliance
conduit fitting (default) Electrical connection 3 ft., 18 GA plenum rated cable, ½”
cable (on/off, MFT, -S types), ½”
Overload protection electronic throughout rotation conduit fitting
conduit fitting
Ambient temperature -22°F to +122°F [-30°C to +50°C] Ambient temperature -22°F to +122°F [-30°C to +50°C]
Overload protection electronic throughout rotation
Auxiliary switch(es) (-S) models: 2 SPDT, 3A (0.5A Overload protection electronic throughout rotation
Ambient temperature -22°F to +122°F [-30°C to +50°C]
inductive) @ 250V, one switch fixed Auxiliary switch(es) add on: 1 or 2 SPDT, 3A (0.5A
Auxiliary switch(es) (-S) models: 1 SPDT, 3A (0.5 A
at 10°, one adjustable 10° to 90° inductive) @ 250V adjustable 5°
inductive) @ 250V adjustable 0°
Housing NEMA 2/IP54, UL enclosure Type 2 to 85°
to 95°
Agency listings cULus according to UL 60730-1A/- Housing NEMA 2, IP54, UL enclosure Type 2
Housing NEMA 2 (IP54) any orientation
2-14, UL 2043, CAN/CSA E60730- Agency listings cULus according to UL 60730-1A/-
Agency listings cULus according to UL 873, UL
1:02, CE according to 2004/108/EC 2-14, UL 2043, CAN/CSA E60730-
2043 and CAN/CSA C22.2 No. 24-93
and 2006/95/EC 1:02, CE according to 2004/108/EC
and 2006/95/EC

 Variable with MFT.

TFB / TFX

O16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


Series
22 in-lbs [2.5 Nm]
Approx. 5.5 sq. ft.

All prices are in US Dollars (USD)


Angle of rotation 95°, adjustable with mechanical
end stops
MFT electronically variable 0-100%
Fits shaft diameter ¼”- ½” (centers on ½”)
Position indication visual indicator
Direction of CW/CCW external switch
rotation (proportional models)
Spring return CW/CCW mounting
reversible
Electrical connection 3 ft., 18 GA plenum cable
(modulating), 3 ft., 18 GA appliance
cable (on/off, -S types), ½” conduit
fitting
Overload protection electronic throughout rotation
Ambient temperature -22°F to +122°F [-30°C to +50°C]
Auxiliary switch(es) (-S) models: 1 SPDT, 3 A (0.5 A
inductive) @ 250V adjustable 0°
to 95°
Housing NEMA 2 (IP42), UL enclosure Type
2, any orientation
Agency listings cULus according to UL60730-
1A/-2-14, UL 2043, CAN/CSA
E60730-1:02, CE according to
2004/108/EC and 2006/95/EC

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

2-8
3
FIRE AND SMOKE
DAMPER ACTUATORS
Technology that Saves Lives
• Lowest power consumption life safety
actuators available in the market.
• ISO 9001 Certified Quality Control and a
5-year warranty assure reliable operation
with exceptional customer support.
• Extensive product range offers 18 in-lbs
to 180 in-lbs for 250°F and 350°F elevated
temperatures in UL 555S applications.

Mike Knipple, Manager, Product Management


Air and Actuator Solutions
Fire and Smoke Damper Actuator Nomenclature

FS L F 120 -S US
Fire and Torque Rating Actuator Type Power Supply Generation Control
Smoke A = 180 in-lbs F = Fail-Safe 24 = 24 VAC/DC Blank = Original Blank = On/Off -S = Built-in
N = 70 in-lbs FB = Fail-Safe, 120 = 120 VAC A = New Generation -SR = 2-10 VDC* Auxiliary
Modulating On/Off Switches
L = 30 in-lbs 230 = 230 VAC
(180 in-lb only)
T = 18 in-lbs

*Available in FSAFB24-XX series only

Ordering Example

1 Choose the actuator. FSLF 120 -S US

2 Specify power supply.

3
Designate
control

120 = 120 VAC -S = Built-in Auxiliary Switches

4 Complete Ordering Example: FSLF120-S US


PROBLEM

SOLUTION
Optimized
Functionality and
Maximum Safety

Fire and Smoke Damper Actuator Replacement Solutions


Belimo fire and smoke damper actuators are specifically designed for operation with fire, smoke and combination fire, and smoke
dampers in ventilation and air-conditioning systems. An integral part of the life safety system, Belimo fire and smoke actuators provide
high performance, low power consumption, and are compliant with Life Safety Codes and Standards.
• Fire and smoke actuators meet UL555 and UL555S listing with all damper manufacturers
• UL 2043 suitable for use in air handling spaces (plenums)
• Meets New York City OTCR and MEA requirements; California State Fire Marshall Listed
• Compact solutions for area-constrained locations
• Extensive range of torque offerings to fit a variety of applications (18, 30, 70, and 180 in-lbs)
• Saves energy and cost with lowest current draws versus the competition

Retrofit installation instructions available online or for assistance with your project; contact Belimo Technical Support at 800-543-9038
(USA) or 866-805-7089 (Canada).

Discover the advantages


www.belimo.us/firesmoke
FSAF*A, FSAFB, FSNF,
FSLF, FSTF Power
Supply
Power
Consumption
Running
Time
Control
Input
Auxiliary
Switches
List
Price

Fire and Smoke


Fail-Safe Damper
Actuator Product Range

VA Rating Running

Motor Drive
24 VAC/DC

120 VAC

230 VAC

Fail-Safe

2 SPDT
2 SPST
On/Off
FSAF24A ● 32‡ <25 <15 ● $722
FSAF24A-S ● 32‡ <25 <15 ● ● $843
FSAF*A Series FSAF120A ● 38 ‡
<25 <15 ● $794
FIRE AND SMOKE

180 in-lbs [20 Nm]


Approx. 18 sq. ft. @ 350°F FSAF120A-S ● 38‡ <25 <15 ● ● $914
FSAF230A ● 37 ‡
<25 <15 ● $940
FSAF230A-S ● 37‡ <25 <15 ● ● $1,060
FSAFB Series FSAFB24-SR ● 9 <75 <20 2-10 VDC $903
180 in-lbs [20 Nm]
Approx. 18 sq. ft. @ 250°F FSAFB24-SR-S ● 9 <75 <20 2-10 VDC ● $1,024

FSNF24 US ● 27‡ <15 <15 ● $585


FSNF24-S US ● 27 ‡
<15 <15 ● ● $704
FSNF Series FSNF120 US ● 27‡ <15 <15 ● $643
70 in-lbs [8 Nm]
Approx. 12 sq. ft. @ 350°F FSNF120-S US ● 27‡ <15 <15 ● ● $763
FSNF230 US ● 27 ‡
<15 <15 ● $771
FSNF230-S US ● 27‡ <15 <15 ● ● $891
FSLF24 US ● 15 ‡
<15 <15 ● $452
FSLF24-S US ● 15‡ <15 <15 ● ● $539
FSLF Series FSLF120 US ● 17 ‡
<15 <15 ● $498
30 in-lbs [3.5 Nm]
Approx. 4 sq. ft. @ 350°F FSLF120-S US ● 17‡ <15 <15 ● ● $585
FSLF230 US ● 17 ‡
<15 <15 ● $592
FSLF230-S US 17‡ <15 <15 $679

U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


● ● ●

FSTF24 US ● 3 <75 <25 ● $327


FSTF24-S US ● 3 <75 <25 ● ● $410
FSTF Series♦ FSTF120 US ● 3.5 <75 <25 ● $363
18 in-lbs [2 Nm]

All prices are in US Dollars (USD)


Approx. 1.5 sq. ft. @ 250°F FSTF120-S US ● 3.5 <75 <25 ● ● $445
FSTF230 US ● 5.5 <75 <25 ● $450
FSTF230-S US ● 5.5 <75 <25 ● ● $533

VA Rating Note:
The FSAF*A, FSNF, and FSLF series actuators draw more current when driving against any stops. Neither UL nor Belimo require any local fusing or breakers. If used, see
individual data sheets for End Stop current draws and current limit values.

See retrofit installation instructions for details.
Use FSTF actuators only for dampers less than 1.5 sq.ft. at 250°F.
Use FSLF for dampers 4 sq.ft. and less at 350°F. No linkages are currently available.
Use FSNF for dampers 4-12 sq.ft. at 350°F and use FSAF*A for larger dampers and multisection applications. Linkages are available for FSAF*A & FSAFB, FSNF, and FSTF.

3-2
FSAF*A, FSAFB, FSNF, FSLF, FSTF Series
Direct Coupled, Fire and Smoke Fail-Safe Damper Actuators

Actuator Specifications

FSAF*A FSAFB FSNF


Series Series Series
180 in-lbs 180 in-lbs 70 in-lbs
[20 Nm]** [20 Nm]*** [8 Nm]**
Approx. 18 sq. ft. Approx. 18 sq. ft. Approx. 12 sq. ft.
@ 350°F  @ 250°F  @ 350°F 
Control on/off Control modulating Control on/off
Angle of rotation 95° Angle of rotation 95° Angle of rotation 95°
Fits shaft diameter ½”-1.05” (clamp self-centers on Fits shaft diameter ½”-1.05” (clamp self-centers on ½”, Fits shaft diameter ½”-1.05” (clamp self-centers on ½”,
½” and 1.05”. Order 23115-00001 ¾” and 1.05”) ¾” and 1.05”)
insert for ¾”). Position indication visual indicator, 0 to 95° Position indication visual indicator, 0 to 95°
Position indication visual indicator, 0 to 95° Manual override 5 mm hex crank Manual override none

FIRE AND SMOKE


Manual override none Direction of rotation reversible with built-in switch Direction of rotation CW/CCW mounting
Direction of rotation CW/CCW mounting Dimensions 9.69” x 3.86” x 3.42” Dimensions 10.2” x 3.86” x 3.23”
Dimensions 10.2” x 3.86” x 3.23” [246 x 98 x 86 mm] [259 x 98 x 82 mm]
[259 x 98 x 82 mm] Electrical connection 3 ft., 18 GA, ½” conduit fitting Electrical connection 3 ft., 18 GA, ½” conduit fitting
Electrical connection 3 ft., 18 GA, ½” conduit fitting Overload protection electronic throughout rotation Overload protection electronic throughout rotation
Overload protection electronic throughout rotation Auxiliary switches 2 SPDT, 3A (0.5A inductive) Auxiliary switches 2 SPDT, 7A (2.5A inductive) @
Auxiliary switches 2 SPST 6A (2.5A inductive) @ 120/250V 125/250V 125/250V
Housing NEMA 1 Housing NEMA 2/IP54, enclosure Type 2 Housing NEMA 1
Agency listings cULus listed according to UL60730- Agency listings cULus listed acc. to UL60730-1A/-2-14, Agency listings cULus listed according to UL873
1A/-2-14, CAN/CSA E60730-1 CAN/CSA E60730, Listed to UL 2043 and CAN/CSA C22.2 No. 24-93.
andCSA22.2 No. 24-93. Listed to UL per requirements of NEC 300.22 (c) and Listed to UL 2043 per requirements
2043 per requirements of NEC 300.22 IMC 602 for plenum use. of NEC 300.22 (c) and IMC 602 for
(c) and IMC 602 for plenum use. plenum use.

**For UL555S, torque is the same for ½ hour at 350°F. ***For UL555S, torque is the same for ½ hour at 250°F. **For UL555S, torque is the same for ½ hour at 350°F.

FSLF FSTF
Series Series
30 in-lbs 18 in-lbs
[3.5 Nm]** [2 Nm]***
Approx. 4 sq. ft. Approx. 1.5 sq. ft.
U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

@ 350°F  @ 250°F 
Control on/off Control on/off
Angle of rotation 95° Angle of rotation 95°
Fits shaft diameter 3/ ”to ½” (K6 clamp standard); ½” Fits shaft diameter ¼” to ½” (clamp self-centers on ½”)
8
to ¾” (with K6-1 clamp optional) Position indication visual indicator, 0 to 95°
All prices are in US Dollars (USD)

Position indication visual indicator, 0 to 95°


Manual override none
Manual override none
Direction of rotation CW/CCW mounting
Direction of rotation CW/CCW mounting
Dimensions 6.28” x 3.0” x 3.30”
Dimensions 7.03” x 3.86” x 3.23” [159 x 76 x 84 mm]
[179 x 98 x 82 mm] Electrical connection 3 ft., 18 GA, ½” conduit fitting
Electrical connection 3 ft., 18 GA, ½” conduit fitting
Overload protection electronic throughout rotation
Overload protection electronic throughout rotation
Auxiliary switches 2 SPST, 3A (0.5A inductive) @
Auxiliary switches 2 SPST, 3A (0.5A inductive) @ 120 VAC, UL approved
125/250V, 1 mA @ 5 VDC Housing NEMA 2/IP42
Housing NEMA 1
Agency listings cULus listed according to UL60730-1
Agency listings cULus listed according to UL60730-1 A/-2-14, CAN/CSA E60730-1 and
Accessories
A/-2-14, CAN/CSA E60730-1 and CSA 22.2 No. 24-93. Listed to UL located on page 4-12
CSA 22.2 No. 24-93. Listed to UL 2043 per requirements of NEC 300.22
2043 per requirements of NEC 300.22 (c) and IMC 602 for plenum use.
(c) and IMC 602 for plenum use.
**For UL555S, torque is the same for ½ hour at 350°F. ***For UL555S, torque is the same for ½ hour at 250°F.

 Specific models and sizes vary with each damper manufacturer.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

3-3
Be Prepared

Safety Codes Require Periodic Testing of Fire and Smoke Dampers


It is the building owner’s responsibility to keep a log or other documents for periodic testing and any corrective actions taken regarding
fire and smoke dampers. The fire marshal or building official may demand the records required by NFPA 80 (fire) & NFPA 105 (smoke)
when inspecting a building.

Containment Dampers require commissioning and testing at the end of the first year of occupancy, and testing every four years except
in hospitals, every six years. Smoke Control System Dampers require dedicated systems be tested at commissioning and then
semi-annually, and non-dedicated systems at commissioning and then annually. If a damper actuator does not pass your required test,
contact a Belimo Sales Manager to acquire information or to find the accurate replacement solution for your application.

Retrofit installation instructions available online at www.belimo.us/firesmoke or for assistance with your project; contact Belimo
Technical Support at 800-543-9038 (USA) or 866-805-7089 (Canada).

Discover the advantages


www.belimo.us
4
DAMPER ACTUATOR
ACCESSORIES
Enhance Performance
and Add Value
• Universal mounting brackets are designed
for applications where the actuator cannot
be mounted directly to the shaft.
• Jackshaft linkage (ZG-JSL) or crank
arm adaptor kits allow for easy retrofit
applications.
• Programming of any MFT actuator is
possible with ZTH interface, PC-Tool
software, or if equipped with Near Field
Communication (NFC) using the Belimo
Assistant App.

Robin Bristol, Product Specialist


Intelligent
and Powerful

Non Fail-Safe and Electronic Fail-Safe Damper Actuators


Belimo’s PMB and PKB damper actuator series are innovative, energy efficient, and
reliable with its durable construction, reduced weight, high torque (1400 in-lbs), and NEMA
4X rating housing for medium to high velocity and pressure applications. The actuator
series offer Near Field Communication (NFC) for easy programming, commissioning and
troubleshooting, universal power supply capability, and two passive sensor inputs. The
actuator communicates directly with Building Automation System (BAS) and offers cloud
connectivity to ensure optimal performance.

Discover the advantages


www.belimo.us
MFT and NFC Damper Actuator Accessories

EFB AFB NFB TFB PKB GKB NKQB GMB AMB NMB LMB AHB LHB LUB List
PROGRAMMING TOOLS LF
EFX AFX NFX TFX PMB GKX NKQX GMX AMX NMX LMX AHX LHX LUX Price
PC-Tool
Belimo MFT configuration
software (V3.x)
Free download at www.belimo.us No
● ● ● ● ● ● ● ● ● ● ● ● ● ● ●
Charge

INTERFACES, CABLES

ZTH US
Handheld interface module that
allows field programming. Available for all MFT Actuators $808
Includes ZK1-GEN, ZK2-GEN,
and ZK6-GEN cables

ZK1-GEN
Cable for use with ZTH-GEN,
ZTH US, or ZIP-USB-MP US ● ● ● ● ● ● ● ● ● ● ● $123
to connect to actuator via
diagnostic/programming socket

DAMPER ACCESSORIES
ZK2-GEN
Cable for use with ZTH-GEN,
ZTH US, or ZIP-USB-MP US
● ● ● ● ● ● ● ● ● ● ● ● ● ● ● $57
to connect to actuators not
equipped with diagnostic/
programming socket

ZK4-GEN
Cable for use with ZTH US to
Available for all MFT Actuators $123
connect to UK24... gateways and
VRP-M
U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

UK24LON
LON gateway that can connect Available for all MFT Actuators $1,086
up to 8 MFT actuators
All prices are in US Dollars (USD)

UK24BAC
BACnet gateway that can Available for all MFT Actuators $1,086
connect up to 8 MFT actuators

UK24MOD
Modbus gateway that can Available for all MFT Actuators $1,086
connect up to 8 MFT actuators

NFC INTERFACE

ZIP-BT-NFC
Bluetooth® to NFC converter for
temporary wireless operation Available for NFC Labeled Actuators Only $273
of Belimo devices with NFC
capabilities

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

4-1
Mechanical Damper Actuator Accessories

EFB AFB NFB TFB GKB NKQB GMB AMB NMB LMB AHB LHB LUB List
CLAMPS LF
EFX AFX NFX TFX GKX NKQX GMX AMX NMX LMX AHX LHX LUX Price

K9-2
● $55
Standard EFB clamp (½” to 1.05”)

K7-2
Standard AFB/NFB clamp ● ● $34
(½” to 1.05”)

K6 US
● $25
Standard LF clamp (3/8” to ½”)
K6-1
● $21
Jackshaft clamp (½” to ¾”)
K8 US
● $21
Standard TF clamp (¼” to ½”)

K-GM20
● ● $40
Reversible clamp (½” to 1.05”)

K-AM25
● ● ● $27
Standard clamp (½” to 1.05”)
DAMPER ACCESSORIES

K-SA
● ● $34
Reversible clamp (½” to ¾”)
K-NA
● $34
Reversible clamp (½” to ¾”)

K-LM20
● $19
Clamp (¾”)

K-LM16
● $19
Standard clamp (5/8”)

U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


K-LM12
● $19
Clamp (½”)

All prices are in US Dollars (USD)


K-LM10
● $19
Clamp (3/8”)

K-LU
● $36
Spindle clamp (5/16” to ½”)

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

4-2
Mechanical Damper Actuator Accessories

EFB AFB NFB TFB GKB NKQB GMB AMB NMB LMB AHB LHB LUB List
POSITION INDICATORS / ROTATION LIMITERS LF
EFX AFX NFX TFX GKX NKQX GMX AMX NMX LMX AHX LHX LUX Price

IND-EFB
● $20
Position indicator

IND-AFB
● ● $14
Position indicator

IND-LF
● $14
Position indicator
IND-TF
● $14
Position indicator

ZDB-LF
● $14
Angle of rotation limiter for LF

ZDB-TF
● $14
Angle of rotation limiter for TF

DAMPER ACCESSORIES
ZDB-LU
● $18
Angle of rotation limiter for LU

MOUNTING BRACKETS

ZG-100
Right angle ● ● ● ● ● ● ● ● $99
(17” H x 111/8” W x 6” base)
U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

ZG-101
Right angle ● ● ● ● ● ● ● $99
(13” H x 11” W x 77/16” base)
All prices are in US Dollars (USD)

ZG-102
Multiple actuator mounting ● ● ● $97
bracket

ZG-103*
Right angle ● ● ● ● ● $73
(7½” H x 11” W x 2¾” base)

ZG-104
Right angle ● ● ● ● ● $73
(135/8” H x 7½” W x 4” base)

* Positions crank arm in same relative position as crank arm on electric foot mount-type linkage actuators.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

4-3
Mechanical Damper Actuator Accessories

EFB AFB NFB TFB GKB NKQB GMB AMB NMB LMB AHB LHB LUB List
MOUNTING BRACKETS LF
EFX AFX NFX TFX GKX NKQX GMX AMX NMX LMX AHX LHX LUX Price
ZG-105
● $40
Right angle
ZG-112*
Right angle ● $40
(4½” H x 5½” W x 2½” base)

ZG-113*
Right angle ● $40
(4½” H x 5½” W x 2½” base)

ZG-118*
Channel ● ● $66
(5 7/8” H x 5½” W x 219/32” base)

ZG-120
● ● ● ● ● ● ● ● $97
Jackshaft mounting bracket

Z-AF
AF/NF to AFB, AFX/NFB, NFX ● ● $25
DAMPER ACCESSORIES

retrofit mounting bracket

Z-SF
● ● $447
20 piece Z-AF kit

Z-GMA
GM to GMB, GMX retrofit
● ● $21
mounting bracket (supplied with
non fail-safe actuators)

U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


Z-SMA
AM, SM to AMB, AMX retrofit
● $21
mounting bracket (supplied with
non fail-safe actuators)

All prices are in US Dollars (USD)


Z-NMA
NM to NMB, NMX retrofit
● ● $21
mounting bracket (supplied with
non fail-safe actuators)

* Positions crank arm in same relative position as crank arm on electric foot mount-type linkage actuators.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

4-4
Mechanical Damper Actuator Accessories

EFB AFB NFB TFB GKB NKQB GMB AMB NMB LMB AHB LHB LUB
CRANK ARM ADAPTOR KITS LF List Price
EFX AFX NFX TFX GKX NKQX GMX AMX NMX LMX AHX LHX LUX

KH-EFB
● $51
Crank arm

KH-AFB
Crank arm for shafts ● ● $34
to ¾”

KH-LF
Crank arm for shafts ● $32
to ½”

KH-LFV
V-bolt kit for direct ● $14
coupling with KH-LF

KH-TF US
● $36
Crank arm with 5/16” slot

DAMPER ACCESSORIES
KH-TF-1 US
● $36
Crank arm with ¼” slot
AH-GMA
● ● $42
GMB, GMX crank arm
AH-25
NKQ, NMB, NMX and ● ● ● $36
AMB, AMX crank arm

ZG-EFB
● $123
Crank arm adaptor kit
U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

ZG-AFB
● ● $102
Crank arm adaptor kit
All prices are in US Dollars (USD)

ZG-AFB118
● ● $99
Crank arm adaptor kit

ZG-LF112
Crank arm adaptor kit
● $64
(includes ZG-112 &
KH-LF)

ZG-LF2
Crank arm adaptor kit
● $75
(includes mounting
hardware)

ZG-LFC114
Trane Voyager retrofit kit ● $121
(includes retrofit bracket)

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

4-5
Mechanical Damper Actuator Accessories

EFB AFB NFB TFB GKB NKQB GMB AMB NMB LMB AHB LHB LUB
CRANK ARM ADAPTOR KITS LF List Price
EFX AFX NFX TFX GKX NKQX GMX AMX NMX LMX AHX LHX LUX

ZG-ECON1
Honeywell economizer
retrofit kit (includes ● $108
20477-00001 retrofit
bracket)

ZG-ECON2
Honeywell economizer
● $86
retrofit kit (logic module
bracket not included)

20477-00001
Honeywell logic module ● $64
bracket

ZG-TF112
DAMPER ACCESSORIES

Crank arm adaptor kit


● $66
(includes ZG-113 and
KH-TF-1)

ZG-TF2
Crank arm adaptor kit
● $57
(includes mounting
hardware)

ZG-GMA
● ● $108
Crank arm adaptor kit

ZG-NMA

U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


● ● ● $73
Crank arm adaptor kit

LINKAGES

ZG-JSL

All prices are in US Dollars (USD)


Jackshaft linkage
Note: LF requires K6-1
● ● ● ● ● ● ● ● ● $292
clamp
Note: EFB, EFX requires
ZG-121

ZG-JSLA + “Actuator”
Select actuators available
Visit
preassembled to the
www.belimo.us
ZG-JSL. At the factory, ● ● ● ● ●
for Individual
there is a cost savings on
List Prices
the ZG-JSL if assembled
with the actuator

ZG-121
Support plate for ● $64
ZG-JSL with EF actuator

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

4-6
Mechanical Damper Actuator Accessories

EFB AFB NFB TFB GKB NKQB GMB AMB NMB LMB AHB LHB LUB List
BALL JOINTS, DAMPER CLIPS, PUSH RODS LF
EFX AFX NFX TFX GKX NKQX GMX AMX NMX LMX AHX LHX LUX Price
KH6
Universal crank arm for KG6 ball
joint. Slot width ¼” [6.2 mm]. For
● ● ● ● ● $25
damper shafts: 3/8” to 11/16” diameter
[10 to 18 mm] or 3/8” to 9/16” sq.
[10 to 14 mm]
KH8
Universal crank arm for KG8 or
KG10A ball joint. Slot width 21/64”
● ● ● ● ● ● ● $25
[8.2 mm]. For damper shafts: 3/8”
to 11/16” diameter [10 to 18 mm] or
3/ ” to 9/ ” sq. [10 to 14 mm]
8 16

KH10
Universal crank arm.
Slot width 21/64” [8.2 mm]. ● ● ● ● ● $57
For damper shafts 9/16” to 1”
diameter [14 to 25 mm]

KH12
Universal crank arm.
Slot width 21/64” [8.2 mm]. ● ● ● ● ● ● ● $33
For damper shafts ¾” to 1”

DAMPER ACCESSORIES
diameter [20 to 25 mm]

KG6
Ball joint (5/16” diameter rod) ● ● ● ● ● ● $21
zinc plated

KG8
Ball joint (5/16” diameter rod, 90°) ● ● ● ● ● ● ● ● ● ● $27
galvanized steel

KG10A
Ball joint for KH8 (3/8” diameter rod) ● ● ● ● ● ● ● ● ● ● ● $30
zinc plated
U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

SH8
Push rod for KG6 & KG8 ball joints ● ● ● ● ● ● ● ● ● ● $32
(36”, 5/16” diameter)
SH10
All prices are in US Dollars (USD)

Push rod for KG10 ball joints ● ● ● ● ● ● ● ● ● $40


(36”, 3/8” diameter)

ZG-DC1
Damper clip for damper blade, ● ● ● ● ● ● ● ● ● ● $47
3½” width

ZG-DC2
Damper clip for damper blade, ● ● ● ● ● ● ● ● ● ● $52
6” width

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

4-7
Mechanical Damper Actuator Accessories

EFB AFB NFB TFB GKB NKQB GMB AMB NMB LMB AHB LHB LUB List
HOUSINGS LF
EFX AFX NFX TFX GKX NKQX GMX AMX NMX LMX AHX LHX LUX Price

ZS-T
Terminal cover for NEMA 2 ● ● ● $27
(-T models)

ZS-100
Weather shield - galvanneal ● ● ● ● ● ● ● ● ● ● ● $179
(13” L x 8” W x 6” D)

ZS-101
● ● ● ● ● ● ● ● ● ● ● $40
Base plate for ZS-100

ZS-150
Weather shield - polycarbonate
● ● ● ● ● ● ● ● ● ● ● $200
with foam seal
(16” L x 8 3/8” W x 4” D)
DAMPER ACCESSORIES

ZS-260
● ● ● ● ● ● ● $2,983
Explosion proof housing

ZG-109
● ● ● ● ● ● ● $142
Right angle bracket for ZS-260

U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


ZG-110
● ● ● ● ● ● ● $170
Stand-off bracket for ZS-260

ZS-300

All prices are in US Dollars (USD)


NEMA 4X, 304 stainless steel ● ● ● ● ● ● ● $2,459
enclosure

ZS-300-5
NEMA 4X, 316L stainless steel ● ● ● ● ● ● ● $2,975
enclosure

ZS-300-C1
½” Shaft adaptor (standard with ● ● ● ● ● ● ● $374
ZS-300)

ZS-300-C2
● ● ● ● ● ● ● $375
¾” Shaft adaptor

ZS-300-C3
● ● ● ● ● ● ● $546
1” Shaft adaptor

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

4-8
Mechanical Damper Actuator Accessories

EFB AFB NFB TFB GKB NKQB GMB AMB NMB LMB AHB LHB LUB List
SHAFT ADAPTORS LF CM
EFX AFX NFX TFX GKX NKQX GMX AMX NMX LMX AHX LHX LUX Price
AV6-20
6.7” Shaft extension fits ¼” to ● ● ● ● $59
¾” diameter shafts
AV8-25*
9.8” Shaft extension fits 5/16” to ● ● ● ● ● ● ● ● ● ● $70
1” diameter shafts
ZG-JSA-1
● ● ● ● ● ● ● ● $231
1” Jackshaft adaptor [11”]
ZG-JSA-2
● ● ● ● ● ● ● $508
15/16” Jackshaft adaptor [12”]
ZG-JSA-3
● ● ● ● ● ● ● ● $426
1.05” Jackshaft adaptor [12”]
ZG-NMSA-1
Shaft extension for ½” diameter ● ● $64
shafts [3.8” long]

ZG-LMSA
Shaft extension for ½” diameter ● $73
shafts [3” long]

ZG-LMSA-1
Shaft extension for 3/8” ● ● $73
diameter shafts [4” long]

DAMPER ACCESSORIES
ZG-LMSA-½”-5
Shaft extension for ½” diameter ● ● $81
shafts [5” long]

MISCELLANEOUS
EF-P
● ● ● $12
Anti-rotation bracket

AF-P
● ● $12
Anti-rotation bracket

LF-P
● $12
Anti-rotation bracket
TF-P
● ● ● ● ● $9
Anti-rotation bracket
U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

Z-DS1
Rotary support for lateral force ● ● $42
compensation

Z-KSA
● $54
All prices are in US Dollars (USD)

5/ ” Shaft clevis
16

Z-KSC
3/ ”- 16 Shaft clevis
● $54
8

ZG-119
● ● $62
Bracket for linear actuators

Tool-06 No
● ● ● ● ● ● ● ●
8 mm and 10 mm wrench Charge
Tool-07 No
● ● ●
13 mm wrench Charge

Z-ARCM
Anti-rotation bracket ● $7
(product sold in quantities of 20)

Z-PICM
Position indicator ● $9
(product sold in quantities of 20)

*K6-1 Accessory clamp is needed for use with LF actuators.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

4-9
Electronic Damper Actuator Accessories

EFB AFB NFB TFB GKB NKQB GMB AMB NMB LMB AHB LHB LUB List
AUXILIARY SWITCHES & POTENTIOMETERS LF
EFX AFX NFX TFX GKX NKQX GMX AMX NMX LMX AHX LHX LUX Price

S1A
Auxiliary switch, 1x SPDT, 3A ● ● ● ● ● ● $101
resistive (0.5A inductive) @ 250 VAC

S2A
Auxiliary switch, 2x SPDT, 3A ● ● ● ● ● ● $151
resistive (0.5A inductive) @ 250 VAC

P475
Shaft mount, non-Mercury
● ● ● ● ● ● ● ● ● ● ● ● $196
auxiliary switch for ½” diameter
shafts
P475-1
Shaft mount, non-Mercury
● ● ● ● ● ● ● ● ● ● ● ● $211
auxiliary switch for 1” diameter
shafts
P140A GR
● ● ● ● ● ● $165
Feedback potentiometer 140 Ω
P500A GR
● ● ● ● ● ● $165
Feedback potentiometer 500 Ω
DAMPER ACCESSORIES

P1000A GR
● ● ● ● ● ● $165
Feedback potentiometer 1000 Ω

P2800A GR
● ● ● ● ● ● $165
Feedback potentiometer 2800 Ω
P5000A GR
● ● ● ● ● ● $165
Feedback potentiometer 5000 Ω
P10000A GR
● ● ● ● ● ● $165
Feedback potentiometer 10000 Ω

P15000A-F GR
● ● ● $371
Feedback potentiometer 15000 Ω

U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


Z-SPA*
Adaptor for auxiliary switches and ● ● $20
potentiometers

CONTROL & POSITIONING

All prices are in US Dollars (USD)


SGA24 (surface mount)
Positioner for remote control ● ● ● ● ● ● ● ● ● ● ● ● ● ● $181
(modulating models)

SGF24 (flush mount)


Positioner for remote control ● ● ● ● ● ● ● ● ● ● ● ● ● ● $155
(modulating models)

ZG-SGF
● ● ● ● ● ● ● ● ● ● ● ● ● ● $30
Mounting plate for SGF

IRM-100
Input rescaling module ● ● ● ● ● ● ● ● ● ● ● ● ● ● $252
(modulating models)

PTA-250
Pulse width modulation interface ● ● ● ● ● ● ● ● ● ● ● ● ● ● $320
(modulating models)

*For use on all NKQ actuators with switches and potentiometers.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

4-10
Electronic Damper Actuator Accessories

EFB AFB NFB TFB GKB NKQB GMB AMB NMB LMB AHB LHB LUB List
CONTROL & POSITIONING LF
EFX AFX NFX TFX GKX NKQX GMX AMX NMX LMX AHX LHX LUX Price
ZG-R01
4 to 20 mA adaptor, 500 Ω, ¼” W ● ● ● ● ● ● ● ● ● ● ● ● ● ● $25
resistor with 6” pigtail wires

ZG-R02
● ● ● ● ● ● ● ● ● ● ● ● ● ● $36
50% voltage divider

ZG-R03
Resistor kit for -MFT95 actuators ● ● ● ● ● $25
in a 0 to 135 Ω control application

MISCELLANEOUS

PS-100
● ● ● ● ● ● ● ● ● ● ● ● ● ● $1,631
Actuator power supply simulator

NSV24 US
● ● ● ● ● ● ● $940
Battery back-up module

DAMPER ACCESSORIES
NSV-BAT
12V 1.2AH battery ● ● ● ● ● ● ● $143
(2 required for NSV24 US)

ZG-X40
● ● ● ● ● ● ● ● ● ● ● ● ● ● $106
120 to 24 VAC, 40 VA transformer

TF-CC US
● ● ● ● ● ● ● ● ● ● ● ● ● $18
Conduit connector
U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

43442-00001
Cable gland ● ● ● ● ● ● $17
(for NEMA 4 models)
All prices are in US Dollars (USD)

11097-00001
Gasket for cable gland ● ● ● ● ● ● $6
(for NEMA 4 models)

ZG-CBLS
Electrical junction box for LF ● $106
actuators

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

4-11
Specialized Fire and Smoke Damper Actuator Accessories

List
FIRE AND SMOKE ACCESSORIES FSAFB FSAF*A FSNF FSLF FSTF
Price

BAE165 US
● ● ● ● ● $239
165°F Electric thermal sensor. SPST, NC

IND-AF2
● $18
Position indicator

KH-AF US
● $41
Actuator arm

KH-AF-1 US
● $75
Crank arm for up to 1.05” shaft

K4-1 US
● $40
Jackshaft clamp for up to 1.05”

SGA24 (with enclosure)


DAMPER ACCESSORIES

Remote potentiometer 0-10 VDC ● $181


for FSAF24-SR & FSAFB24-SR

SGF24 (no enclosure)


Remote potentiometer 0-10 VDC ● $155
for FSAF24-SR & FSAFB24-SR

S2A-F US
Auxiliary switch, 2x SPDT, 3A resistive ● ● ● ● $354
(0.5A inductive) @ 250 VAC

ZDB-AF2 US
● $31
Angle of rotation limiter

U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


ZG-AF US
● $121
Crank arm adaptor kit

All prices are in US Dollars (USD)


ZG-AF108
● $126
Crank arm adaptor kit

ZG-AFA108
Mounting bracket, crank arm, and ● $146
hardware for FSAF*A actuators

ZG-AFA
Leg kit, angle brackets, crank arm, and ● $141
hardware for FSAF*A actuators

See individual Fire and Smoke data sheets for a complete list of accessories for each actuator.
NOTE: FSAFB24-SR(-S) uses the same accessories as the AFB series actuators.
FSAF*A uses legacy generation linkage kits and the new generation KH-AFB crank arm. No rotation limiter exists.
FSAFB uses AFB/NFB accessories.
FSAF and FSNF series actuators use legacy generation linkages.
FSLF series actuators have no linkage capability.
FSTF series actuators use TF and TFB series linkage kits and accesories. FSTF does not have linkage or rotation limiting capability. Use IND-LF on page 4-3.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

4-12
Standard and Customizable Damper Actuation
The damper actuator section now showcases products in an easy-to-read layout for quicker
product selection. All actuator models are grouped first by non fail-safe then fail-safe GMB...
functionality followed by torque from highest to lowest. Basic (“B“ model) and Customizable
B = Basic stocked product
(“X“ model) actuators are now consecutively listed including the NEMA 4/4X model offerings.

Belimo actuators are designed for compatibility with many different control signals and GMX...
requirements of HVAC equipment. Belimo is an innovator in IoT based actuation with many X = Customizable product
new products offering connectivity to BACnet/IP and MS/TP and Modbus RTU and TCP. These
IP and MOD designated products enable sensor integration directly into the actuator for
digitization and processing. Refer to page 22-2 on “How to Size and Select“ a damper actuator.

Basic actuators provide fixed functionality according to typical application requirements. Accessories can be added in the field such as the
mechanical interfaces, mounting brackets, and crank arms.

Customizable actuators allow for factory configuration, selection of mechanical and electrical interfaces, control options, and with
Multi-Function Technology (MFT) will enable you to modify voltage control (VDC), time proportional control (PWM), floating point (-3),
and on/off control signals. In addition, MFT makes it easy to set parameters for feedback position (VDC), running time, mechanical
working range, address, status, and diagnostics.

CUSTOMIZED OPTIONS
Factory ordered customizable product(s) contain an actuator re-order number allowing for fast reordering of the same configuration.
The re-order number is printed on the actuators label, shipping documents, and on the invoice.

To expedite orders, some customizable products are automatically converted to the basic (B) version when the selected mechanical
interface, wiring connection, and programming codes are equal to the basic product.

Select MFT actuators are field configurable with the ZTH handheld tool, MFT PC-Tool software and Near Field Communication (NFC) with
the Belimo Assistant App (ZIP-BT-NFC converter for Apple devices).

The customization process has four selection criteria.

1 Actuator model (page 4-14)


U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

2 Select the desired mechanical interface (page 4-15)


3 Select the desired electrical interface (page 4-15)
4 Select the desired configurable control options, if an MFT actuator is selected, select the desired control input, position feedback,
and runtime (page 4-15)
All prices are in US Dollars (USD)

Each customizable selection has a code associated and these codes are combined to create the re-order number. Some options have an
additional fee.

Reorder # for a EFX24-MFT-S


EF N4 Reorder # for a GMX24-MFT
GM
2 is: EFKL0100A01 2 is: GM1101C3A01

1 4 No Charge 4 No Charge
3 No Charge 1 3 $31
4
2 No Charge 2 No Charge
1 $1,754 4
1 $815
$1,754 Final Price $846 Final Price
3
3

4-13
Base Actuator to Customize Model

1 Select an Actuator.

Model Base Actuator ID Model Base Actuator ID Model Base Actuator ID


AFX24 AF200 EFX120-S N4H EFK30 LUX120-SR LU460
AFX24 N4 AFG200 EFX120-SR N4 EFKR0 LUX24-3 LU010
AFX24-MFT AF600 EFX120-SR-S N4 EFKT0 LUX24-MFT LU100
AFX24-MFT N4 AFG600 EFX24-MFT EF600 LUX24-SR LU040
AFX24-MFT95 AFE10 EFX24-MFT-S EF620 NFX24 NF200
AFX24-MFT95 N4 AFGE10 EFX24-MFT-S N4 EFKL0 NFX24 N4 NFG200
AFX24-MFT-S AF620 EFX24-MFT-S N4H EFKM0 NFX24-MFT NF600
AFX24-MFT-S N4 AFG620 EFX24-S EF220 NFX24-MFT N4 NFG600
AFX24-S AF220 EFX24-S N4 EFK60 NFX24-MFT-S NF620
AFX24-S N4 AFG220 EFX24-S N4H EFK70 NFX24-MFT-S N4 NFG620
AFX24-SR AF400 EFX24-SR EF400 NFX24-S NF220
AFX24-SR N4 AFG400 EFX24-SR-S EF420 NFX24-S N4 NFG220
AFX24-SR-S AF420 EFX24-SR-S N4 EFKE0 NFX24-SR NF400
AFX24-SR-S N4 AFG420 EFX24-SR-S N4H EFKF0 NFX24-SR N4 NFG400
AFXUP AF000 GKX24-3 GK4K0 NFX24-SR-S NF420
AFXUP N4 AFG000 GKX24-3-T N4 GKG4T0 NFX24-SR-S N4 NFG420
AFXUP-S AF020 GKX24-3-T N4H GKG4T0 NFXUP NF000
AFXUP-S N4 AFG020 GKX24-MFT GK4J0 NFXUP N4 NFG000
CUSTOMIZED OPTIONS

AHKX24-MFT-100 AHK4J0 GKX24-MFT-T N4 GKG4N0 NFXUP-S NF020


AHX120-3-100 AH060 GKX24-MFT-T N4H GKG4N0 NFXUP-S N4 NFG020
AHX24-MFT-200 AH280 GKX24-SR GK6K0 NKQX24-1 NKQDL0
AMCX24-MFT AMC110 GKX24-SR GR GKEE0 NKQX24-MFT NKQDJ0
AMCX24-MFT95 AMC0M0 GKX24-SR-T N4 GKG4F0 NKQX24-SR NKQDM0
AMCX24-MFT-T N4 AMP3K0 GMX120-3 GM580 NMCX24-MFT NMC110
AMQX24-1 AMQD60 GMX24-3 GM540 NMQX24-1 NMQD60
AMQX24-MFT AMQD00 GMX24-3-T N4 GMGHT0 NMQX24-MFT NMQD00
AMX120-3 AM060 GMX24-3-T N4H GMGHT0 NMX120-3 NM060
AMX120-SR AM450 GMX24-MFT GM110 NMX120-SR NM450
AMX24-3 AM000 GMX24-MFT N4 GMG110 NMX24-3 NM000
AMX24-3-S AM020 GMX24-MFT-T N4 GMG3K0 NMX24-3-F NM010
AMX24-3-T AMT00 GMX24-PC GM0P0 NMX24-3-T NMT00

U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


AMX24-3-T N4 AMPT00 GMX24-SR GM560 NMX24-3-T N4 NMPT00
AMX24-3-T N4H AMPT00 GMX24-SR-T N4 GMGGT0 NMX24-3-T N4H NMPT00
AMX24-MFT AM100 LHX120-3-200 LH070 NMX24-MFT NM100
AMX24-MFT N4 AMP100 LHX120-3-300 LH180 NMX24-MFT N4 NMP100

All prices are in US Dollars (USD)


AMX24-MFT95 AM0L0 LHX24-MFT-100 LH100 NMX24-MFT95 NM0L0
AMX24-MFT-T N4 AMPUN0 LHX24-MFT-200 LH280 NMX24-MFT-T NMUN0
AMX24-PC AM0N0 LHX24-MFT-300 LH790 NMX24-MFT-T N4 NMPUN0
AMX24-SR AM030 LHX24-SR-200 LH040 NMX24-SR NM030
AMX24-SR-T AMT40 LMQX24-MFT LMQD00 NMX24-SR-T NMT40
AMX24-SR-T N4 AMPT40 LMX120-3 LM060 NMX24-SR-T N4 NMPT40
AMX24-SR-T N4H AMPT40 LMX120-3-F LM070 NMX24-SR-T N4H NMPT40
EFCX120-S N4 EFGH0 LMX120-SR LM450 TFCX120-S TF2D0
EFCX24-S N4 EFGL0 LMX120-SR-F LM460 TFX120 TF650
EFX120 EF650 LMX24-3 LM000 TFX120-S TF660
EFX120-S EF670 LMX24-3-F LM010 TFX24 TF200
EFX120-S N4 EFK20 LMX24-3-F-T LMT10 TFX24-3 TFB10
LMX24-3-S LM020 TFX24-3-S TFB24
LMX24-3-T LMT00 TFX24-MFT TF950
LMX24-MFT LM100 TFX24-MFT-S TF9A0
LMX24-MFT95 LM0L0 TFX24-S TF210
LMX24-SR LM030 TFX24-SR TF400
LMX24-SR-F LM040 TFX24-SR-S TF410
LMX24-SR-T LMT40

4-14
2 Select a Mechanical Interface.
Mechanical Interface Non Fail-Safe Fail-Safe
ID Description GMX AMX NMX LMX AHX LHX LUX GKX EFX AFX NFX TFX NKQX
0 No insert in hollow shaft ● ● ● ● ● ● ● ● ● ● ● ●

1 Clamp standard ● ● ● ● ● ● ● ● ● ●

2 Clamp 3⁄8” ● ●

4 Clamp ½” ●

6 Clamp ¾” ●

8 Clamp LU 8 to 12 mm ●

9 Clamp LU 8 to 12 mm with endstops ● ● ●

A Formfit 8 x 8 mm ●

B Formfit 8 x 8 mm position indicator ● ● ●

D Formfit 10 x 10 mm position indicator ●

J Clamp 1” D-shaft ●

3 Select the Electrical Interface.


Mechanical Interface Non Fail-Safe Fail-Safe
ID Description GMX AMX NMX LMX AHX LHX LUX GKX EFX AFX NFX NKQX TFX
01 Cable, 3 ft. [1 m] PVC ●

31 Cable, 3 ft. [1 m] plenum, without connector ● ● ● ● ● ● ●

33 Cable, 10 ft. [3 m] plenum, without connector ● ● ● ●

CUSTOMIZED OPTIONS
35 Cable, 16 ft. [5 m] plenum, without connector ● ●

111 Cable, 16 ft. [5 m] plenum, without connector ●

00 Terminals ●

01 Cable, 3 ft. [1 m] PVC ● ● ● ● ●

02 Cable, 10 ft. [3 m] PVC ● ●

03 Cable, 16 ft. [5 m] PVC ● ●

1A1 Cable, 16 ft. [5 m] FRNC ●

31 Cable, 16 ft. [5 m] FRNC ● ● ●

33 Cable, 16 ft. [5 m] FRNC ●

35 Cable, 16 ft. [5 m] FRNC ●

A1 Cable, 3 ft. [1 m] PVC connector


U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

● ● ● ● ● ● ● ● ● ● ●

A3 Cable, 10 ft. [3 m] PVC connector ● ● ● ● ● ● ●

A5 Cable, 16 ft. [5 m] PVC connector ● ● ● ● ● ●

C1 Cable, 3 ft. [1 m] plenum, with connector, without SL ● ● ● ● ● ● ● ● ● ● ● ● ●


All prices are in US Dollars (USD)

C3 Cable, 10 ft. [3 m] plenum, with connector, without SL ● ● ● ● ● ● ● ● ● ●

C5 Cable, 16 ft. [5 m] plenum, with connector, without SL ● ● ● ● ● ● ● ● ● ●

E3 Cable, 10 ft. [3 m] plenum 20mA connector ●

T1 Terminal unprotected ● ● ● ● ●

T2 Terminal cover connector ●

4 Select a Control Option.


Program Codes Non Fail-Safe Fail-Safe
ID Description GMX AMX AMQX NMX NMQX LMX LMQX AHX LHX LUX GKX EFX AFX NFX NKQX TFX
A01 VDC; In 2-10V; Out 2-10V; 150s ● ● ● ● ● ● ● ● ● ● ●
A02 VDC; In 0.5-10V; Out 0.5-10V;150s ● ● ● ● ● ● ● ● ● ● ●
A03 VDC; In 2-10V; Out 0.5-5V; 150s ● ● ● ● ● ● ● ●
A06 VDC; In 10.5-13.5V; Out 2-10V; 150s ●
A08 VDC; In 0.5-5V; Out 0.5-10V; 150s ●
A09 VDC; In 5-10V; Out 2-10V; 150s ●
A11 VDC; In 0.5-5V; Out 0.5-5V; 150s ●
A13 VDC; In 0.5-10V; Out 2-10V; 150s ●
A16 VDC; In 2-6V; Out 2-10V; 150s ●
A17 VDC; In 6-10V; Out 2-10V; 150s ●
A19 VDC; In 2-10V; Out 2-10V; 100s ● ●
A28 VDC; In 0.5-10V; Out 0.5-10V; 100s ● ● ● ● ●
A37 VDC; In 0.5-10V; Out 0.5-10V; 120s ●

4-15
4 Control Options continued.

Program Codes Non Fail-Safe Fail-Safe


ID Description GMX AMX AMQX NMX NMQX LMX LMQX AHX LHX LUX GKX EFX AFX NFX NKQX TFX
A39 VDC; In 10-14V; Out 2-10V; 150s ●
A42 VDC; In 0.5-10V; Out 2-10V; 75s ● ●
A55 VDC; In 2-5V; Out 2-10V; 75s ●
A62 VDC; In 2-10V; Out 2-10V; 90s ● ● ● ●
A63 VDC; In 0.5-4.5V; Out 0.5-4.5V; 150s ●
A64 VDC; In 5.5-10V; Out 5.5-10V; 150s ● ●
A72 VDC; In 2-10V; Out 2-10V; 95s ●
A91 VDC; In 2-10V; Out 2-10V; 95s ●
AAA VDC; In 2-22V; Out 2-10V; 150s ●
AAT VDC; In 2-10V; Out 2-10V; 20s ●
AAX VDC; In 2-10V; Out 2-10V; 35s ● ● ●
AC0 VDC; In 2-10V; Out 2-10V; 45s ●
AC1 VDC; In 2-10V; Out 2-10V; 90s ● ●
AC5 VDC; In 2-10V; Out 2-10V; 75s ● ● ● ●
AD6 VDC; In 2-10V; Out 0.5-5V; 100s ● ●
AE0 VDC; In 2-10V; Out 2-10V; 90s ●
AE2 VDC; In 2-10V; Out 2-10V; 150s ●
F01 Floating; In Float; Out 2-10V; 150s ● ● ● ● ● ● ●
F05 Floating; In Float; Out 0.5-10V; 100s ● ● ●
F06 Floating; In Float; Out 0.5-5V; 150s ●
F14 Floating; In Float; Out 2-10V; 90s ●
CUSTOMIZED OPTIONS

F19 VDC; In Float; Out 2-10V; 45s ●


F1A VDC; In Float; Out 2-10V; 35s ●
H01 VDC; In 2-10V; Out 2-10V; 95s ● ● ● ●
H02 VDC; In 2-10V; Out 2-10V; 150s ● ● ●
H06 VDC; In 2-10V; Out 2-10V; 90s ● ●
H07 VDC; In 2-10V; Out 2-10V; 75s ● ●
H15 VDC; w/o Close-Off Func; 2-10V; 35s ●
H34 Floating; In Float,Out 2-10V; 95s ●
J01 On/Off; In On/Off; Out 2-10V; 75s ●
R01 R95; In 135Ohm; Out 2-10V; 150s ● ● ● ●
R04 R95; In 135Ohm; Out 2-10V; 75s ● ●
R05 R95; In 135Ohm; Out 0.5-10V; 100s ● ●

U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


R09 R95; In 135Ohm; Out 2-10V; 90s ● ●
R0A R95; In 135Ohm; Out 2-10V; 37s ●
S01 PC; In Phasecut; Out 2-10V; 150s ●
S04 PC; In Phasecut; Out 2-10V; 90s ●

All prices are in US Dollars (USD)


T01 Q-VDC; In 2-10V; Out 2-10V; 2.5s ●
T02 Q-VDC; In 2-10V; Out 2-10V; 4s ● ●
T03 Q-VDC; In 2-10V; Out 2-10V; 7s ●
T04 Q-VDC; In 2-10V; Out 2-10V; 10s ●
T07 Q-VDC; In 0.5-10V; Out 0.5-10V; 2.5s ●
T08 Q-VDC; In 0.5-10V; Out 0.5-10V; 4s ● ●
T09 Q-VDC; In 0.5-10V; Out 0.5-10V; 7s ●
T0A Q-VDC; In 0.5-10V; Out 0.5-10V; 10s ● ● ●
T0C Q-VDC; In 0.5-10V; Out 0.5-10V; 15s ●
T0H Q-OC; In Open/Close; Out 2-10; 4s ● ●
T0J Q-OC; In Open/Close; 7s ●
T0L Q-VDC; In 2-10V; Out 2-10V; 4s ●
T0N Q-VDC; In 2-10V; Out 2-10V; 10s ●
T0S Q-OC; In Open/Close; Out 2-10V; 15s ●
T0T Q-OC; In Open/Close; Out 2-10V; 20s ●
W01 PWM; In 0.59-2.93s; 2-10V; 150s ● ●
W02 PWM; In 0.02-5s; Out 2-10V; 150s ● ● ● ● ● ●
W03 PWM; 0.1-25.5s; Out 2-10V; 150s ● ● ●
W06 PWM; 0.59-2.93s; 0.5-5V; 150s ●
W32 PWM; 0.1-25.5s; Out 2-10V; 100s ●
W34 PWM; In 0.59-2.93s; 2-10V; 100s ● ●
W3F PWM; In 0.1-25.5s; Out 0.5-5V; 150s ●
W3L PWM; In 0.2-5s; Out 2-10V; 150s ● ● ●

4-16
PRESSURE INDEPENDENT VALVES
ENERGY VALVES
PRESSURE INDEPENDENT
VALVES (ENERGY VALVES,
ePIV & PIQCV)
Perfectly Balanced Room Comfort
• Pressure independent valve technology
provides better comfort while saving energy.
• Automatic dynamic balancing optimizes
system performance at all times.
• Improves Delta T reducing pumping and
chiller costs.

Rodrigo Marques de Sá, Product Manager


PRESSURE INDEPENDENT VALVES
ENERGY VALVES

Perfect Dynamic
Balancing

6-Way Energy
Features PIQCV ePIV
ePIV Valve
Glycol Monitoring •
True Flow • • •
Dynamic Balancing • • • •
Energy Meter •
Power Control •
Pressure Independent Valves Delta T Manager •
Belimo pressure independent valves combine the function of a balancing Cloud Analytics •
valve and a control valve to supply an accurate and stable flow independent Live Data • • •
of changes in pressure. The valves stabilize variable flow hydronic systems Coil History •
for a lifetime of efficiency and worry-free operation. With Belimo pressure CCV Technology • • • •
independent technology, every system performs to its full potential – saving 0% Leakage • • • •
time, money, and energy resources. Field Configuration • • • •
BACnet MS/TP or IP, Modbus
• • •
RTU or TCP/IP
Discover the advantages
www.belimo.us 5-Year Warranty • • • •
7-Year Warranty with Cloud

Access
5
ENERGY VALVES

Solving Low Delta T Leveraging IoT


• IoT cloud-connected device utilizes
advanced analytic technology to leverage
system data to improve coil and system
performance.
• Delta T Manager algorithm reduces pumping
and chiller/boiler operating costs by
increasing plant efficiency by maintaining a
higher Delta T.
• Integrated energy meter provides accurate
coil data to verify performance during
commissioning and system optimization.

Marc Noteware, Purchasing Manager Americas


Energy Valve Nomenclature

EV 250S -127 +ARB 24 -EV

Energy Valve Size Flow Rate Pressure Actuator Type Power


Valve 050 = ½” 1.65 - 713 GPM Rating Non Fail-Safe Supply EV = ½” to 6” -L = 2½”
NPT 2-way 075 = ¾” Refer to valve Blank = ANSI 125 LRB, LRX 24 = 24 VAC/DC to 3”*
(½” to 2”) pages for a -250 = ANSI 250 NRB, NRX -B = 4”
100 = 1”
Flanged 2-way full list ARB, ARX to 6”*
125 = 1¼” GRB, GRX
(2½” to 6”) -G = Glycol
150 = 1½” EVX* Measurement
200 = 2” Electronic Fail-Safe
250 = 2½” AKRB, AKRX
300 = 3” GKRB, GKRX
400 = 4” AVKX*
500 = 5”
600 = 6” “X” models are customizable.
S = Stainless Refer to page 5-3 for programming options.

Steel Ball and


Stem

*ANSI 250 electromagnetic models only

Energy Valve Set Up Options- Default Ordering Example


The Energy Valve can be ordered two different ways once the valve and actuator are selected in the
valve section starting on page 5-8.
1. Default. The product is shipped already programmed with the default settings below. The default
models use actuators that contain a B in the actuator part number i.e. EV250S-127+ARB24-EV.
2. Programmed. The product will ship to the specific settings ordered by the customer using the
Program Codes in steps 1 through 7 on the next page. The programmed models use actuators that
contain an X in the actuator part number i.e. EV250S-127+ARX24-EV.
NOTE: If no specific settings are selected, the product will ship with the default settings below.

DEFAULT SETTINGS
Installation Control and
Maximum Flow Delta T Manager Delta T Setpoint Actuator Setup
Position Feedback Signal
Maximum flow of Return Off 10°F [5.6°C] Non Fail-Safe Control Signal (Y)
the valve Normally Closed (NC) DC 2 to 10V
Electronic Fail-Safe Feedback Signal (U)
Normally Closed (NC) / DC 2 to 10V
Fail Closed (FC)

COMPLETE DEFAULT ORDERING EXAMPLE:


EV250S-127+ARB24-EV
Energy Valve Set Up Options
Programmed Ordering Example

Follow steps 1 through 7.


1. SELECT CODE FOR MAXIMUM FLOW
The maximum GPM can be factory set to the values below. Select the flow code for the desired GPM of the corresponding valve size.

2” 2”
Flow Code ½” GPM ¾” GPM 1” GPM 1¼” GPM 1½” GPM 2½” GPM 3” GPM 4” GPM 5” GPM 6” GPM
(76.1 GPM) (100 GPM)
30 1.65 3.1 5.5 8.6 11.9 22.8 30 38 54 95 149 214
37 2 3.8 6.7 10.5 14.7 28.2 37 47 67 117 183 264
45 2.5 4.6 8.2 12.8 17.8 34.2 45 57 81 143 223 321
55 3 5.7 10 15.7 21.8 41.9 55 70 99 174 272 392
63 3.5 6.5 11.5 18 24.9 47.9 63 80 113 200 312 449
65 3.6 6.7 11.8 18.5 25.7 49.5 65 83 117 206 322 463
68 3.7 7 12.4 19.4 26.9 51.7 68 86 122 216 337 485
71 3.9 7.3 12.9 20.2 28.1 54 71 90 128 225 351 506
72 4 7.4 13.1 20.5 28.5 54.8 72 91 130 228 356 513
75 4.1 7.7 13.7 21.4 29.7 57.1 75 95 135 238 371 535
76 4.2 7.8 13.8 21.7 30.1 57.8 76 97 137 241 376 542
78 4.3 8 14.2 22.2 30.9 59.4 78 99 140 247 386 556
80 4.4 8.2 14.6 22.8 31.7 60.9 80 102 144 254 396 570
82 4.5 8.4 14.9 23.4 32.5 62.4 82 104 148 260 406 585
83 4.6 8.5 15.1 23.7 32.9 63.2 83 105 149 263 411 592
85 4.7 8.8 15.5 24.2 33.7 64.7 85 108 153 269 421 606
87 4.8 9 15.8 24.8 34.5 66.2 87 110 157 276 431 620
89 4.9 9.2 16.2 25.4 35.2 67.7 89 113 160 282 441 635
91 5 9.4 16.6 25.9 36 69.3 91 116 164 288 450 649
93 5.1 9.6 16.9 26.5 36.8 70.8 93 118 167 295 460 663
95 5.2 9.8 17.3 27.1 37.6 72.3 95 121 171 301 470 677
97 5.3 10 17.7 27.6 38.4 73.8 97 123 175 307 480 692
00 5.5 10.3 18.2 28.5 39.6 76.1 100 127 180 317 495 713

2. SELECT CODE FOR INSTALLATION POSITION 3. SELECT CODE FOR DELTA T MANAGER STATUS
Where the Energy Valve is installed in a system either on the supply or return. The Delta T Manager provides a fixed delta T setpoint.
Delta T Scaling varies the setpoint.

ENERGY VALVE
Code Description
A Supply Code Description
U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

Z Return 0 OFF
1 ON Delta T Manager
2 ON Delta T Scaling
All prices are in US Dollars (USD)

4. SELECT CODE FOR DELTA T SETPOINT


This is the Delta T limit of the coil

Code Description Code Description Code Description Code Description Code Description Code Description Code Description
02 02°F / 1.1°C /K 17 17°F / 9.4°C/K 32 32°F / 17.8°C/K 47 47°F / 26.1°C/K 62 62°F/ 34.4°C/K 77 77°F/ 42.7°C/K 92 92°F/ 51.1°C/K

03 03°F / 1.7°C/K 18 18°F / 10.0°C/K 33 33°F / 18.3°C/K 48 48°F / 26.7°C/K 63 63°F/ 35.0°C/K 78 78°F/ 43.3°C/K 93 93°F/ 51.6°C/K

04 04°F / 2.2°C/K 19 19°F / 10.6°C/K 34 34°F / 18.9°C/K 49 49°F / 27.2°C/K 64 64°F/ 35.5°C/K 79 79°F/ 43.8°C/K 94 94°F/ 52.2°C/K
05 05°F / 2.8°C/K 20 20°F / 11.1°C/K 35 35°F / 19.4°C/K 50 50°F / 27.8°C/K 65 65°F/ 36.1°C/K 80 80°F/ 44.4°C/K 95 95°F/ 52.7°C/K
06 06°F / 3.3°C/K 21 21°F / 11.7°C/K 36 36°F / 20.0°C/K 51 51°F / 28.3°C/K 66 66°F/ 36.6°C/K 81 81°F/ 45.0°C/K 96 96°F/ 53.3°C/K
07 07°F / 3.9°C/K 22 22°F / 12.2°C/K 37 37°F / 20.6°C/K 52 52°F / 28.9°C/K 67 67°F/ 37.2°C/K 82 82°F/ 45.5°C/K 97 97°F/ 53.8°C/K
08 08°F / 4.4°C/K 23 23°F / 12.8°C/K 38 38°F / 21.1°C/K 53 53°F / 29.4°C/K 68 68°F/ 37.7°C/K 83 83°F/ 46.1°C/K 98 98°F/ 54.4°C/K
09 09°F / 5.0°C/K 24 24°F / 13.3°C/K 39 39°F / 21.7°C/K 54 54°F / 30.0°C/K 69 69°F/ 38.3°C/K 84 84°F/ 46.6°C/K 99 99°F/ 55.0°C/K
10 10°F / 5.6°C/K 25 25°F / 13.9°C/K 40 40°F / 22.2°C/K 55 55°F / 30.6°C/K 70 70°F/ 38.8°C/K 85 85°F/ 47.2°C/K 100 100°F/ 55.5°C/K
11 11°F / 6.1°C/K 26 26°F / 14.4°C/K 41 41°F / 22.8°C/K 56 56°F / 31.1°C/K 71 71°F/ 39.4°C/K 86 86°F/ 47.7°C/K
12 12°F / 6.7°C/K 27 27°F / 15.0°C/K 42 42°F / 23.3°C/K 57 57°F / 31.7°C/K 72 72°F/ 40.0°C/K 87 87°F/ 48.3°C/K
13 13°F / 7.2°C/K 28 28°F / 15.6°C/K 43 43°F / 23.9°C/K 58 58°F / 32.2°C/K 73 73°F/ 40.5°C/K 88 88°F/ 48.8°C/K
14 14°F / 7.8°C/K 29 29°F / 16.1°C/K 44 44°F / 24.4°C/K 59 59°F / 32.8°C/K 74 74°F/ 41.1°C/K 89 89°F/ 49.4°C/K
15 15°F / 8.3°C/K 30 30°F / 16.7°C/K 45 45°F / 25.0°C/K 60 60°F / 33.3°C/K 75 75°F/ 41.6°C/K 90 90°F/ 50.0°C/K
16 16°F / 8.9°C/K 31 31°F / 17.2°C/K 46 46°F / 25.6°C/K 61 61°F/ 33.8°C/K 76 76°F/ 42.2°C/K 91 91°F/ 50.5°C/K

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

5-3
Energy Valve Set Up Options
Programmed Ordering Example Continued

5. SELECT CODE FOR ACTUATOR SETUP 6. SELECT CODE FOR CONTROL AND FEEDBACK SIGNAL

NON FAIL-SAFE Code Description


Code Description 0 Control Signal (Y)
DC 0.5 to 10V
1 NO
Feedback Signal (U)
2 NC DC 0.5 to 10V
ELECTRONIC FAIL-SAFE 2 Control Signal (Y)
Code Description DC 2 to 10V

3 NO/FO Feedback Signal (U)


DC 2 to 10V
4 NO/FC
This selection does not affect BACnet functions.
5 NC/FO
6 NC/FC

7. DOES THE ORDER REQUIRE TAGGING?


Part number for tagging: 99981-00101
Valves may be tagged per customer specification. ($12.00 charge per tag)
Example: AHU-1
FCU-2

Part Number for tagging:


99981-00101

COMPLETE PROGRAMMED ORDERING EXAMPLE


ENERGY VALVE

EV250S-127+ARX24-EV(00, Z,0,10, 2, 2)

U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


2 - Control and Feedback Signal, 2 to 10V
2 - Normally Closed

All prices are in US Dollars (USD)


10 - Delta T Setpoint, 10°F [5.6°C]
0 - Delta T Manager, OFF
Z - Installed on Return Side
00 - Maximum Flow, 127 GPM

COMPLETE DEFAULT ORDERING EXAMPLE:


EV250S-127+ARB24-EV

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

5-4
Energy Valve Product Range

Valve Nominal
Type Suitable Actuators
Size
DN Non Electronic
GPM Range Inches 2-way
[mm] Fail-Safe Fail-Safe

1.65 - 5.5* ½ 15 EV050S-055 EV

LRB(X)24-EV(-G)
Mode of Operation
3.1 - 10.3* ¾ 20 EV075S-103 The Energy Valve is an energy metering pressure independent
control valve that optimizes, documents, and proves water coil
performance.
5.5 - 18.2* 1 25 EV100S-182
Product Features
Measures Energy: using its built-in electronic flow sensor and

AKRB(X)24-EV(-G)
NRB(X)24-EV(-G)
NPT

8.6 - 28.5* 1¼ 32 EV125S-285 supply and return temperature sensors.


Controls Power: with its Power Control logic, providing linear
heat transfer regardless of temperature and pressure variations.
11.9 - 39.6* 1½ 40 EV150S-396 Manages Delta T: by solving Low Delta T Syndrome. In addition,
it reduces pumping costs while increasing chiller/boiler efficiency
by optimizing coil efficiency.
22.8 - 76.1* 2 50 EV200S-761
Actuator Specifications
ARB(X)24-EV(-G)

Control type modulating


30-100* 2 50 EV200S-1000** Manual override LR, NR, AR, GR, AKR, GKR, EV, AVK
Electrical connection 3 ft. [1 m] cable with ½” conduit fitting
38 - 127* 2½ 65 EV250S-127
Valve Specifications
54 - 180* 3 80 EV300S-180 Service chilled or hot water, 60% glycol
Flanged ANSI 125

(open loop and steam not allowed)


Flow characteristic equal percentage/linear
95 - 317* 4 100 EV400S-317
GKRB(X)24-EV(-G)
GRB(X)24-EV(-G)

Controllable flow range 75°


Action stem up - open A to AB
149 - 495* 5 125 EV500S-495 Sizes ½”, ¾”, 1”, 1¼”, 1½”, 2”, 2½’’, 3’’, 4’’, 5’’, 6’’
End fitting NPT female (½”- 2”)
pattern to mate with ANSI 125 or 250 flange (2½”- 6”)
214 - 713* 6 150 EV600S-713 Materials
U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

Body
Valve forged brass, nickel plated (½”- 2”)
cast iron - GG25 (2½”- 6”)
AVKX24-EV-L
EVX24-EV-L

38 - 127* 2½ 65 EV250S-127-250
Sensor housing forged brass, nickel plated (½”- 2”)
ductile iron - GGG50 (2½”- 6”)
Ball stainless steel
Flanged ANSI 250
All prices are in US Dollars (USD)

54 - 180* 3 80 EV300S-180-250 Stem stainless steel


Plug stainless steel (-250)
Seats Teflon® PTFE, stainless steel (-250)
95 - 317* 4 100 EV400S-317-250 Characterizing disc Tefzel® (½”- 2”)
AVKX24-EV-B
EVX24-EV-B

stainless steel (2½”- 6”)


149 - 495* 5 125 EV500S-495-250 Stem packing EPDM (lubricated), NLP (-250)
Media temp range 14°F to 250°F [-10°C to +120°C],
39°F to 250°F [4°C to 120°C](EV200S-1000)
214 - 713* 6 150 EV600S-713-250 Body pressure rating 360 psi (½”- 2”), ANSI 125, Class B (2½”- 6”)
ANSI 250 (2½”-6”)
*V’nom = Maximum flow for each valve body size. Close-off pressure 200 psi (½”- 2”), 100 psi (2½”- 6”),
** Media temperature range is 39°F to 250°F [4°C to 120°C] varies by size (-250)
Differential pressure
range (∆P) see application pages
Leakage 0%, ANSI Class IV (-250)

Inlet length to meet


specified measurement
accuracy 5x nominal pipe size (NPS)
Communication BACnet IP, BACnet MS/TP, listed by BTL, web
server, Modbus RTU/IP, Belimo MP-Bus
Remote temperature
sensor length
½”- 2” 2 ft. 7.5 in. [0.8 m] short, 9.8 ft. [3 m] long
2½”- 6” 32.8 ft. [10 m]

5-5
Energy Valves
Operation/Installation

SET-UP - Specify Upon Ordering

2-WAY VALVE
LRX...Series NC: Normally Closed- NO: Normally Open-
NON FAIL-SAFE

NRX...Series valve will open as voltage valve will close as voltage


STAYS IN LAST
POSITION

ARX...Series increases. increases.


GRX...Series Y Signal controls the valve position.
EVX...Series Y Signal
Y Signal controls
controls the
the valve
valve position.
position.
STAYS IN FAIL-SAFE POSITION

AKRX...Series NO/FO Valve: Normally NO/FC Valve: Normally NC/FO Valve: Normally NC/FC Valve: Normally
ELECTRONIC FAIL-SAFE

GKRX...Series Open-valve will close as Open-valve will close as Closed-valve will open as Closed-valve will open
AVKX...Series voltage increases. voltage increases. voltage increases. as voltage increases.
Fail Action: Will fail open Fail Action: Will failthe flow.
Y Signal controls Fail Action: Will fail open Fail Action: Will fail
upon power loss. closed uponcontrols
Y Signal
Y Signal power
controls
theloss.
flow.
the flow. upon power loss. closed upon power
loss.
T2
*Feedback signal is always NC T2
T2

T1
T1
T1
FUNCTIONALITY Y Signal controls the coil thermal power
The Energy Valve offers different operating modes which can be selected using the Web(BTU/hr
setpoint
Y Signal View or
controls orkW).
the ZTHthermal
coil US. power
Y Signal (BTU/hr
setpoint controlsor
thekW).
coil thermal power
setpoint (BTU/hr or kW).
Delta T Manager OFF Delta T Manager ON
T2
Position Control T2 Position Control + Delta T Manager
T2
The Energy Valve works as a normal The Energy Valve works as a pressure
Position Control

pressure dependent valve. The dependent valve. If the measured ∆T is lower


actuator is positioned based on the T1 than the ∆T setpoint the flow will be reduced
DDC control signal. T1 by the Delta T Manager logic to achieve the
ENERGY VALVE

T1
setpoint, regardless of the control signal Y.
Y Signal controls the valve position as long Note: In position control, only ∆T Manager can be
Y Signal controls the valve position. Y
asSignal
the ∆Tcontrols
is abovethe
thevalve position as long
∆T setpoint. selected, ∆T Manager Scaling will not be available.

U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


YY Signal Y the ∆Tcontrols
asSignal is abovethe ∆T setpoint.
thevalve position as long
Signal controls the valve
controls the valveposition.
position.
as the ∆T is above the ∆T setpoint.

T2
Pressure Independent Flow Control T2 Pressure Independent Flow Control+
The Energy Valve works as an ePIV T2 Delta T Manager

All prices are in US Dollars (USD)


Flow Control

(Electronic Pressure Independent The Energy Valve works as an ePIV. However,


Valve). The valve reacts to any T1
if the measured ∆T is lower than the ∆T
change in pressure and modulates T1 setpoint, the flow will be reduced by the Delta
the actuator to maintain the flow T1 T Manager logic to achieve the ∆T setpoint,
Y Signal controls the flow. setpoint based on the DDC control regardless of the control signal Y.
Y Signal controls the flow as long as the ∆T
Y
is Signal
above controls the flow as long as the ∆T
YY Signal
Signal controls
controls the
the flow.
flow. signal. the ∆T setpoint.
is above the
Y Signal ∆T setpoint.
controls the flow as long as the ∆T
is above the ∆T setpoint.
T2
Power Control Power Control + Delta T Manager
T2 T2
T2 The Energy Valve adjusts flow to T2 The Energy Valve adjusts flow to maintain
maintain the thermal power setpoint. T2 the thermal power setpoint. If the measured
Power Control

If the measured coil power is below coil power is below setpoint, flow will be
T1
setpoint, flow will be increased. If increased. If the measured coil power is
T1 T1
T1
the measured coil power is above T1 above setpoint, flow will be decreased as long
setpoint, flow will be decreased as T1
as the defined V’max is not exceeded. If the
Y Signal controls the coil thermal power
setpoint long as the defined V’max is not measured ∆T is lower than the ∆T setpoint,
Y Signal(BTU/hr
controlsorthekW).
coil thermal power Y Signal controls the thermal power
Ysetpoint
Signal (BTU/hr
controlsorthekW).
coil thermal power exceeded. Y Signal as
setpoint controls
long asthethe
thermal power the ∆T
∆T is above flow will be reduced by the Delta T Manager
setpoint as long as the ∆T is above the ∆T
setpoint (BTU/hr or kW). setpoint.
Y Signal
setpoint. controls the thermal power logic and will override the thermal power
setpoint as long as the ∆T is above the ∆T control setpoint.
T2 setpoint.
T2

T2

T1
T1

T1
Y Signal controls the valve position as long
as
Y Signal 800-543-9038
the ∆Tcontrols
is above ∆T setpoint.
thevalve
the USA
position as long 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN
as the ∆T is above the ∆T setpoint.
5-6 Y Signal controls the valve position as long
as the ∆T is above the ∆T setpoint.
Energy Valves
Operation/Installation

INSTALLATION
Inlet Length
The Energy Valve requires a section of straight pipe on the valve inlet to guarantee sensor accuracy. This section
should be at least 5 pipe diameters long with respect to the size of the valve.

½” [DN15] 5 x nominal pipe size = 2½” [64 mm] ½” - 2” [DN15-DN50]


¾” [DN20] 5 x nominal pipe size = 3¾” [95 mm]
1” [DN25] 5 x nominal pipe size = 5” [127 mm]
1¼” [DN32] 5 x nominal pipe size = 6¼” [159 mm]
1½” [DN40] 5 x nominal pipe size = 7½” [191 mm]
2” [DN50] 5 x nominal pipe size = 10” [254 mm]
5 x Nominal Pipe Size (NPS)

Flow
2½” [DN65] 5 x nominal pipe size = 12½” [317 mm]
3” [DN80] 5 x nominal pipe size = 15” [381 mm]
4” [DN100] 5 x nominal pipe size = 20” [508 mm] 2½” - 6” [DN65-DN150]
5” [DN125] 5 x nominal pipe size = 25” [635 mm]
6” [DN150] 5 x nominal pipe size = 30” [762 mm]

Outlet Length
No requirements for outlet length. 5 x Nominal Pipe Size (NPS)

Elbows can be installed directly after the valve.


Flow

PIPING

The Energy Valve is recommended to be installed on the return side of the coil. This diagram illustrates a typical application. Consult engineering specification and
drawings for particular circumstances.

For 2½” through 6” valves, install the provided


thermowell on the other side of the coil (T1). For ½”
through 2” valves, both temperature sensors are remote
and are supplied with female NPT threaded pipe body.

ENERGY VALVE
The (T2) sensor should be installed downstream in
the direction of flow after the valve assembly. The (T1)
sensor should be installed on the other side of the coil.
U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

Belimo recommends installing one strainer per system. If


the system has multiple branches, it is recommended to
install one strainer per branch.
All prices are in US Dollars (USD)

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

5-7
Energy Valves with Non Fail-Safe and Electronic Fail-Safe Actuators
2-way Valves with Stainless Steel Ball and Stem, Threaded NPT

Valve Specifications
chilled or hot water, up to 60%
Service glycol max (open loop/steam not
allowed)
Flow Characteristic equal percentage/linear
End Fitting NPT female
Body forged brass, nickel plated with cloud
Sensor Housing forged brass, nickel plated connectivity
Ball stainless steel
Stem stainless steel
Seat Teflon® PTFE
Stem Packing EPDM
Media Temp. Range
14°F to 250°F [-10°C to +120°C]
1.65 to 76.1 GPM
Media Temp. Range
39°F to 250°F [4°C to 120°C]
EV200S-1000
Diff. Pressure Range 5 to 50 psid or 1 to 50 psid with
1.65 to 76.1 GPM flow reductions*
Diff. Pressure Range 8 to 50 psid or 1 to 50 psid with
EV200S-1000 (100 GPM) flow reductions*
Leakage 0%
Inlet Length to Meet
Specified Measurement 5X nominal pipe size (NPS)
Accuracy
ultrasonic with glycol and
Flow Sensor Technology
temperature compensation
Power Supply for the
actuator is powered by the sensor
Flow Sensor
Remote Temperature standard: 2 ft 7.5 in [0.8m],
Sensor Length 9.8 ft. [3m]

ACTUATOR PART # LRX24-EV LRX24-EV-G NRX24-EV NRX24-EV-G ARX24-EV ARX24-EV-G AKRX24-EV AKRX24-EV-G
Glycol Measurement • • • •
Control Modulating Modulating Modulating Modulating Modulating Modulating Modulating Modulating
Manual Override • • • • • • • •
Running Time (Motor) 90 seconds 90 seconds 90 seconds 90 seconds 90 seconds 90 seconds 90 seconds 90 seconds
18 GA plenum 18 GA plenum 18 GA plenum 18 GA plenum 18 GA plenum 18 GA plenum 18 GA plenum 18 GA plenum
rated cable and rated cable and rated cable and rated cable and rated cable and rated cable and rated cable and rated cable and
Electrical Connection
RJ45 socket RJ45 socket RJ45 socket RJ45 socket RJ45 socket RJ45 socket RJ45 socket RJ45 socket
ENERGY VALVE

(Ethernet) (Ethernet) (Ethernet) (Ethernet) (Ethernet) (Ethernet) (Ethernet) (Ethernet)


2-Way
Body Close-Off
Size

U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


Model # GPM Pressure Pressure
[mm]
Rating [psi] [psi]
EV050S-055 5.5 ½” [15] $1,436 $1,864 $2,087 $2,515
EV075S-103 10.3 ¾” [20] $1,484 $1,912 $2,182 $2,609
EV100S-182 18.2 1” [25] $1,578 $2,005 $2,442 $2,869

All prices are in US Dollars (USD)


EV125S-285 28.5 1¼” [32] 360 200 $2,085 $2,513 $2,522 $2,949
EV150S-396 39.6 1½” [40] $2,239 $2,667 $2,755 $3,182
EV200S-761 76.1 2” [50] $2,648 $3,075 $3,093 $3,520
EV200S-1000 100 2” [50] $2,648 $3,075 $3,093 $3,520

Electronic Fail-Safe actuators: AKRX24-EV, AKRX24-EV-G


* See flow reduction chart in technical documentation.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

5-8
Energy Valves with Non Fail-Safe and Electronic Fail-Safe Actuators
2-way Valves with Stainless Steel Ball and Stem, Flanged Ends

Valve Specifications
chilled or hot water, up to 60%
Service glycol max (open loop/steam not
allowed)
Flow Characteristic equal percentage/linear
pattern to mate with ANSI 125
End Fitting
flange with cloud
Body cast iron - GG25 connectivity
Sensor Housing ductile iron - GGG50
Ball stainless steel
Stem stainless steel
Seat PTFE
Stem Packing EPDM (lubricated)
Media Temperature Range
14°F to 250°F [-10°C to +120°C]
(Water)
5 to 50 psid or 1 to 50 psid with
Differential Pressure Range
flow reductions*
Leakage 0%
Inlet Length to Meet
Specified Measurement 5X nominal pipe size (NPS)
Accuracy
Flow Sensor Technology electromagnetic
Power Supply for the
actuator is powered by the sensor
Flow Sensor
standard: 32.8 ft. [10m]
Remote Temperature
optional: 4.9 ft. [1.5m], 9.8 ft. [3m],
Sensor Length
16.4 ft. [5m]

ACTUATOR PART # ARX24-EV GRX24-EV AKRX24-EV GKRX24-EV


Control Modulating Modulating Modulating Modulating
Manual Override • • • •
Running Time (Motor) 90 seconds 90 seconds 90 seconds 90 seconds

18 GA plenum rated cable and 18 GA plenum rated cable and 18 GA plenum rated cable and 18 GA plenum rated cable and
Electrical Connection
RJ45 socket (Ethernet) RJ45 socket (Ethernet) RJ45 socket (Ethernet) RJ45 socket (Ethernet)

2-Way
Body Close-Off
Size
Model # GPM Pressure Pressure

ENERGY VALVE
[mm]
Rating [psi] [psi]
EV250S-127 127 2½” [65] $9,053 $10,455
EV300S-180 180 3” [80] $11,749 $13,152
U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

ANSI 125,
EV400S-317 317 4” [100] Standard 100 $13,633 $15,372
EV500S-495 495 5” [125] Class B $16,870 $18,609
EV600S-713 713 6” [150] $21,565 $23,305

Electronic Fail-Safe actuators: AKRX24-EV and GKRX24-EV


All prices are in US Dollars (USD)

* See flow reduction table in technical documentation.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

5-9
Energy Valves with Non Fail-Safe and Electronic Fail-Safe Actuators
2-way Valves with Stainless Steel Plug and Stem, ANSI 250 Flanged Ends

Valve Specifications
chilled or hot water, up to 60%
Service glycol max (open loop/steam not
allowed)
Flow Characteristic equal percentage/linear
pattern to mate with ANSI 250
End Fitting
flange with cloud
Body cast iron - GG25 connectivity
Sensor Housing ductile iron - GGG50
Plug stainless steel
Stem stainless steel
Seat stainless steel
Stem Packing EPDM NLP (no lip packing)
Media Temperature Range
14°F to 250°F [-10°C to +120°C]
(Water)
7.5 to 50 psid or 1 to 50 psid with
Differential Pressure Range
flow reductions*
Leakage ANSI IV
Inlet Length to Meet
Specified Measurement 5X nominal pipe size (NPS)
Accuracy
Flow Sensor Technology electromagnetic
Power Supply for the
actuator is powered by the sensor
Flow Sensor
standard: 32.8 ft. [10m]
Remote Temperature
optional: 4.9 ft. [1.5m], 9.8 ft. [3m],
Sensor Length
16.4 ft. [5m]

ACTUATOR PART # EVX24-EV-L EVX24-EV-B AVKX24-EV-L AVKX24-EV-B


Control Modulating Modulating Modulating Modulating
Manual Override • • • •
Running Time (Motor) 90 seconds 90 seconds 90 seconds 90 seconds
18 GA plenum rated cable and 18 GA plenum rated cable and 18 GA plenum rated cable and 18 GA plenum rated cable and
Electrical Connection
RJ45 socket (Ethernet) RJ45 socket (Ethernet) RJ45 socket (Ethernet) RJ45 socket (Ethernet)
2-Way
Body
Close-Off
GPM Size Pressure
Model # Pressure
Range [mm] Rating
[psi]
ENERGY VALVE

[psi]
EV250S-127-250 38-127 2½” [65] 310 $13,079 $14,735
EV300S-180-250 54-180 3” [80] 310 $15,784 $17,439

U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


EV400S-317-250 95-317 4” [100] ANSI 250, 310 $18,172 $19,827
EV500S-495-250 149-495 5” [125] Standard 296 $22,854
EV500S-495-250 149-495 5” [125] Class B 202 $24,509
EV600S-713-250 214-713 6” [150] 215 $26,922
EV600S-713-250 214-713 6” [150] 135 $28,577

All prices are in US Dollars (USD)


Electronic Fail-Safe actuators: AVKX24-EV-L, AVKX24-EV-B
* See flow reduction table in technical documentation.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

5-10
6
ELECTRONIC PRESSURE
INDEPENDENT CONTROL
VALVES (ePIV)
High Performance Solution
• Valve maintains flow set point regardless of
system pressure variations based on its true
flow measurement.
• Automatic dynamic balancing optimizes
system performance at all times.
• Simplifies commissioning and eliminates the
need for a manual balance valve.

Tricia Bruenn, Senior Manager, Strategic Initiatives


Electronic Pressure Independent Valve (ePIV) Nomenclature

P6 250SU -127 +ARX 24 -EP2 -MOD


Electronic Valve Size Flow Rate Pressure Actuator Type Power
Pressure 050 = ½” 127 GPM Rating Non Fail-Safe Supply EP = ½” to 2” -L = 2½” Modbus &
Independent 075 = ¾” Refer to valve Blank = ANSI LRX 24 = 24 EP2 = ½” to 6” to 3”** BACnet
Valve 125 VAC/DC (SU) -B = 4” communication*
100 =1” pages for full list NRX PI = 2½” to 6” to 6”**
P2- NPT 2-way 125 = 1¼” -250 = ANSI ARX
(½” to 2”) 250 Modulating
150 = 1½” GRX Control
P6- Flanged 2-way
(2½” to 6”) 200 = 2” EVX**
250 = 2½” Electronic
300 = 3” Fail-Safe
400 = 4” AKRX
500 = 5” GKRX
600 = 6” AVKX**
S = Stainless Steel
Ball and Stem
SU = Ultrasonic
Flow Sensor

*Only available with non fail-safe actuators (NPT and ANSI 125 models - ANSI 250 is SU version only).
**ANSI 250 models only

Ordering Example

3 Select programming code

1 Choose the valve actuator combination.

P6250SU-127+ARX24-EP2 NC Tagging (if needed)


4
2 Specify preference or configuration.
Does order
require
Set-Up tagging?

D01
Non Fail-Safe Models Tagging:
NO = Normally Open D00 0.5 to 10 VDC
Valves may be
NC = Normally Closed D01 2 to 10 VDC tagged per customer
specification. ($12.00
Electronic Fail-Safe Models charge per tag)
NO/FO = Normally Open/Fail Open
NO/FC = Normally Open/Fail Closed Example:
AHU-1
NC/FO = Normally Closed/Fail Open FCU-2
NC/FC = Normally Closed/Fail Closed
Part number for tagging:
Refers to valve ports from inlet to outlet, 99981-00101
per flow arrow.

5 Complete Ordering Example: P6250SU-127+ARX24-EP2


Configuration:
+NC
Programming: +D01

NOTE: All SU models should be entered with the GPM designed - in case GPM is not provided this will come with V'nom set up.
Electronic Pressure Independent Control Valve (ePIV) Product Range

Valve Nominal Size Type Suitable Actuators


Electronic
GPM Range Inches DN [mm] 2-way Non Fail-Safe
Fail-Safe

LRX24-EP(2)(-MOD)
1.65 - 5.5* ½ 15 P2050S(U)

3.1 - 10.3* ¾ 20 P2075S(U) Equal Percentage


ePIV Characteristic

5.5 - 18.2* 1 25 P2100S(U) Mode of Operation


The Electronic Pressure Independent Control Valve

AKRX24-EP(2)
(ePIV) is a two-way valve which is unaffected by pressure

NRX24-EP(2)
variations in a system.
NPT

8.6 - 28.5* 1¼ 32 P2125S(U)

(-MOD)
Product Features
Provides constant flow regardless of pressure variations
11.9 - 39.6* 1½ 40 P2150S(U) in the system. Simplified valve sizing and selection, no Cv
calculations required.
ARX24-EP(2)
22.8 - 76.1* 2 50 P2200S(U) (-MOD) Actuator Specifications
Control type modulating
Manual override LR, NR, AR, GR, AKR, GKR, EV, AVK
30-100** 2 50 P2200S(U) Electrical connection 3 ft. [1 m] cable with
½” conduit fitting
Communication analog, BACnet MS/TP, Modbus RTU
(EP2)(-MOD)

38 - 127* 2½ 65 P6250S(U)
AKRX24-PI and Belimo MP-Bus (-MOD actuators)
ARX24-PI

(EP2)
Valve Specifications
54 - 180* 3 80 P6300S(U) Service chilled or hot water, 60% glycol
Flanged ANSI 125

(open loop and steam not allowed)


Flow characteristic*** equal percentage/linear
95 - 317* 4 100 P6400S(U)
½”, ¾”, 1”, 1¼”, 1½”, 2”, 2½’’, 3’’,
GKRX24-PI(EP2)

Sizes
GRX24-PI(EP2)

4’’, 5’’, 6’’


(-MOD)

End fitting NPT female (½”-2”)


149 - 495* 5 125 P6500S(U)
pattern to mate with ANSI 125
U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

or 250 flange (2½”- 6”)


Materials
214 - 713* 6 150 P6600S(U) Body
Valve brass, nickel plated (½”-2”)
cast iron-GG25 (2½”-6”)
AVKX24-PI-L,
AKRX24-EP2
EVX24-PI-L,
ARX24-EP2

38 - 127* 2½ 65 P6250S(U)-250 Sensor housing forged brass, nickel plated (½”-2”)


(-MOD)
All prices are in US Dollars (USD)

ductile iron- GGG50 (2½”-6”)


Ball stainless steel
54 - 180* 3 80 P6300S(U)-250 Plug stainless steel (-250)
Flanged ANSI 250

Stem stainless steel


Seats Teflon® PTFE, stainless steel (-250)
95 - 317* 4 100 P6400S(U)-250 Characterizing disc Tefzel® (½”- 2”)
GRX24-EP2(-MOD)

stainless steel (2½”-6”)


AVKX24-PI-B,
GKRX24-EP2
EVX24-PI-B,

Stem packing EPDM (lubricated), NLP (-250)


149 - 495* 5 125 P6500S(U)-250 Media temp range 14°F to 250°F [-10°C to +120°C],
39°F to 250°F [4°C to 120°C]
(P2200S-1000)
Body pressure rating 360 psi (½” to 2”)
214 - 713* 6 150 P6600S(U)-250
ANSI 125, Class B (2½”-6”)
ANSI 250 (2½”-6”) (-250)
*V’nom = Maximum flow for each valve body size. Close-off pressure 200 psi (½”- 2”)
** Applies to 2” ePIV models P2200S-800 through P2200S-1000 only. 100 psi (2½”-6”)
Note: For NPT, ANSI 125 and ANSI 250 versions, flows can be field set to 30% of nominal flow rate. varies by size (-250)
Differential pressure
range (∆P) see technical documentation
Leakage 0%, ANSI Class IV (-250)
Flow sensor technology ultrasonic (½”- 6”)
magnetic (2½”-6”)
Inlet length to meet
specified measurement
accuracy 5x nominal pipe size (NPS)
Conductivity of media min. 20uS/cm (Applies to sizes 2½”
[DN65] to 6” [DN150] only.)
(Electromagnetic Sensor only)
***The flow characteristic can be changed by using the
Belimo PC-Tool software.
6-3
Electronic Pressure Independent Control Valves
P2/P6 Series

SET-UP - Specify Upon Ordering

2-WAY VALVE
STAYS IN LAST POSITION

LRX...Series NC: Normally Closed- NO: Normally Open-


NRX...Series valve will open as voltage valve will close as voltage
NON FAIL-SAFE

ARX...Series increases. increases.


GRX...Series
EVX...Series
STAYS IN FAIL-SAFE POSITION

AKRX...Series NO/FO Valve: Normally NO/FC Valve: Normally NC/FO Valve: Normally NC/FC Valve: Normally
GKRX...Series Open-valve will close as Open-valve will close as Closed-valve will open as Closed-valve will open
ELECTRONIC FAIL-SAFE

AVKX...Series voltage increases. voltage increases. voltage increases. as voltage increases.


Fail Action: Will fail open Fail Action: Will fail Fail Action: Will fail open Fail Action: Will fail
upon power loss. closed upon power loss. upon power loss. closed upon power
loss.

NOTE: Feedback signal is always direct acting (2V close, 10V open). Feedback signal can be set to true flow or valve position. The default is true flow. Actuator default setting is NC or NC/FC.
Changing this setting requires the use of the PC-Tool software.

INSTALLATION
Inlet Length
The ePIV requires a section of straight pipe on the valve inlet to guarantee sensor accuracy. This section should be at least 5 pipe diameters long
with respect to the size of the valve.

DN15-DN50

U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


½” [DN15] 5 x nominal pipe size = 2½” [64 mm]
¾” [DN20] 5 x nominal pipe size = 3¾” [95 mm] NPT Version
1” [DN25] 5 x nominal pipe size = 5” [127 mm]
1¼” [DN32] 5 x nominal pipe size = 6¼” [159 mm]
1½” [DN40] 5 x nominal pipe size = 7½” [191 mm]
2” [DN50] 5 x nominal pipe size = 10” [254 mm] 5 x Nominal Pipe Size (NPS)

All prices are in US Dollars (USD)


2½” [DN65] 5 x nominal pipe size = 12½” [317 mm]
ePIV

3” [DN80] 5 x nominal pipe size = 15” [381 mm] DN65-DN150


4” [DN100] 5 x nominal pipe size = 20” [508 mm] Flanged Versions
5” [DN125] 5 x nominal pipe size = 25” [635 mm]
6” [DN150] 5 x nominal pipe size = 30” [762 mm]

Outlet Length
No requirements for outlet length. 5 x Nominal Pipe Size (NPS)
Elbows can be installed directly after the valve.

NOTE: All tolerances on flow measurement/control will be affected if requirements


are not followed.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

6-4
Electronic Pressure Independent Control Valves
P2/P6 Series

PIPING
The ePIV is recommended to be installed on the return side of the coil. This diagram is for typical applications only. Consult engineering specification and
drawings for particular circumstances. Refer to ePIV technical documentation for flow verification and commissioning procedures.

Belimo recommends installing one strainer per system. If the system has multiple branches, it is recommended to install one strainer per branch.

Electronic Pressure Independent Valves can be piped in a parallel orientation to achieve increased flow rates.

TYPICAL PARALLEL PIPING IN RELATION TO THE INPUT AND OUTPUT

To achieve flows larger than nominal flow, it is recommended to connect two valves in parallel leading to a common manifold. To correctly operate these
valves, Multi-Function Technology (MFT) will be employed to utilize one common control signal. It is recommended to use the same signal in parallel (2-10
VDC); the two actuators are wired from the same control signal and the two valves control the flow in an identical pattern. The resulting flow will be double
an individual valve. This arrangement is preferable to a split signal since it offers a more stable and accurate flow and feedback signal is easier to interpret.
U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

e
All prices are in US Dollars (USD)

ePIV

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

6-5
P2 Series Electronic Pressure Independent Valves
with Non Fail-Safe and Fail-Safe Actuators
2-way Valves with Stainless Steel Ball and Stem, NPT Female Ends

Valve Specifications
chilled or hot water, up to 60% glycol
Service
max (open loop/steam not allowed)
Flow Characteristic equal percentage/linear
*See flow reduction table in technical documentation.
End Fitting NPT female
Body forged brass, nickel plated
Sensor Housing forged brass, nickel plated
Ball stainless steel
Stem stainless steel
Seat Teflon® PTFE
Stem Packing EPDM
Media Temperature Range
14°F to 250°F [-10°C to +120°C]
(Water)
5 to 50 psid or 1 to 50 psid with
Differential Pressure Range
flow reductions*
Leakage 0%
Inlet Length to Meet Specified
5X nominal pipe size (NPS)
Measurement Accuracy
ultrasonic with glycol and
Flow Sensor Technology
temperature compensation
Power Supply for the
sensor is powered by the actuator
Flow Sensor

LRX24-EP2- NRX24-EP2- ARX24-EP2-


ACTUATOR PART # LRX24-EP2 NRX24-EP2 ARX24-EP2 AKRX24-EP2
MOD MOD MOD
Control Modulating Modulating Modulating Modulating Modulating Modulating Modulating
Manual Override • • • • • • •
Running Time (Motor) 90 seconds 90 seconds 90 seconds 90 seconds 90 seconds 90 seconds 90 seconds
Running Time (Fail-Safe) 35 seconds
Modbus & BACnet • • •
3 ft, 18 GA 3 ft, 18 GA 3 ft, 18 GA 3 ft, 18 GA 3 ft, 18 GA 3 ft, 18 GA 3 ft, 18 GA
plenum cable plenum cable plenum cable plenum cable plenum cable plenum cable plenum cable
Electrical Connection
with ½” conduit with ½” conduit with ½” conduit with ½” conduit with ½” conduit with ½” conduit with ½” conduit
connector connector connector connector connector connector connector
Fail-Safe •
2-Way
Body
Close-Off
Size Pressure
Model # GPM Pressure

U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


[mm] Rating
[psi]
[psi]
P2050SU-055 5.5 ½” [15] 200 $952 $1,047 $1,400
P2075SU-103 10.3 ¾” [20] 200 $969 $1,067 $1,426
P2100SU-182 18.2 1” [25] 200 $1,003 $1,103 $1,475

All prices are in US Dollars (USD)


P2125SU-285 28.5 1¼” [32] 360 200 $1,764 $1,941 $2,122
P2150SU-396 39.6 1½” [40] 200 $1,895 $2,085 $2,345
P2200SU-761 76.1 200 $2,225 $2,447 $2,619
ePIV

2” [50]
P2200SU-1000 100 200 $2,225 $2,447 $2,619

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

6-6
P6 Series Electronic Pressure Independent Valves
with Non Fail-Safe Actuators
2-way Valves with Stainless Steel Ball and Stem, Flanged Ends
Valve Specifications
chilled or hot water, up to 60% glycol
Service
max (open loop/steam not allowed)
Flow Characteristic equal percentage/linear
pattern to mate with ANSI 125
End Fitting
flange
Body cast iron - GG25
Sensor Housing ductile iron - GGG50
Ball stainless steel
Stem stainless steel
Seat Teflon® PTFE
Stem Packing EPDM
Media Temperature Range
14°F to 250°F [-10°C to +120°C]
(Water)
5 to 50 psid or 1 to 50 psid with
Differential Pressure Range
flow reductions*
Leakage 0%
Inlet Length to Meet
Specified Measurement 5X nominal pipe size (NPS)
Accuracy
Flow Sensor Technology electromagnetic
Power Supply for the Flow
sensor is powered by the actuator
Sensor

ACTUATOR PART # ARX24-PI ARX24-PI-MOD


Control Modulating Modulating
Manual Override • •
Running Time (Motor) 90 seconds 90 seconds
Modbus & BACnet •
Electrical Connection 3 ft, 18 GA plenum cable with ½” conduit connector 3 ft, 18 GA plenum cable with ½” conduit connector

2-Way
Body Close-Off
Size
Model # GPM Pressure Pressure
[mm]
Rating [psi] [psi]
P6250S-080 80 100 $7,642 $8,406
P6250S-085 85 100 $7,642 $8,406
P6250S-090 90 100 $7,642 $8,406
P6250S-100 100 100 $7,642 $8,406
U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

2½”
P6250S-105 105 100 $7,642 $8,406
[65]
P6250S-110 110 100 $7,642 $8,406
P6250S-115 115 100 $7,642 $8,406
P6250S-121 121 ANSI 125, 100 $7,642 $8,406
Standard
P6250S-127 127 Class B 100 $7,642 $8,406
All prices are in US Dollars (USD)

P6300S-133 133 100 $9,914 $10,906


P6300S-141 141 100 $9,914 $10,906
P6300S-149 149 100 $9,914 $10,906
3”
P6300S-157 157 100 $9,914 $10,906
[80]

ePIV
P6300S-165 165 100 $9,914 $10,906
P6300S-173 173 100 $9,914 $10,906
P6300S-180 180 100 $9,914 $10,906
*See flow reduction table in technical documentation.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

6-7
P6 Series Electronic Pressure Independent Valves
with Non Fail-Safe Actuators
2-way Valves with Stainless Steel Ball and Stem, Flanged Ends
Valve Specifications
chilled or hot water, up to 60% glycol
Service
max (open loop/steam not allowed)
Flow Characteristic equal percentage/linear
pattern to mate with ANSI 125
End Fitting
flange
Body cast iron - GG25
Sensor Housing ductile iron - GGG50
Ball stainless steel
Stem stainless steel
Seat Teflon® PTFE
Stem Packing EPDM
Media Temperature Range
14°F to 250°F [-10°C to +120°C]
(Water)
5 to 50 psid or 1 to 50 psid with
Differential Pressure Range
flow reductions*
Leakage 0%
Inlet Length to Meet
Specified Measurement 5X nominal pipe size (NPS)
Accuracy
Flow Sensor Technology electromagnetic
Power Supply for the Flow
sensor is powered by the actuator
Sensor

ACTUATOR PART # GRX24-PI GRX24-PI-MOD


Control Modulating Modulating
Manual Override • •
Running Time (Motor) 90 seconds 90 seconds
Modbus & BACnet •
Electrical Connection 3 ft, 18 GA plenum cable with ½” conduit connector 3 ft, 18 GA plenum cable with ½” conduit connector

2-Way
Body Close-Off
Size
Model # GPM Pressure Pressure
[mm]
Rating [psi] [psi]
P6400S-195 195 100 $11,499 $12,650
P6400S-210 210 100 $11,499 $12,650
P6400S-225 225 100 $11,499 $12,650
P6400S-240 240 100 $11,499 $12,650

U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


4”
P6400S-255 255 100 $11,499 $12,650
[100]
P6400S-270 270 100 $11,499 $12,650
P6400S-285 285 100 $11,499 $12,650
P6400S-300 300 100 $11,499 $12,650
P6400S-317 317 100 $11,499 $12,650

All prices are in US Dollars (USD)


P6500S-335 335 100 $14,205 $15,626
P6500S-353 353 100 $14,205 $15,626
P6500S-371 371 100 $14,205 $15,626
P6500S-389 389 100 $14,205 $15,626
ePIV

P6500S-407 407 5” ANSI 125, 100 $14,205 $15,626


P6500S-425 425 [125] Standard 100 $14,205 $15,626
P6500S-443 443 Class B 100 $14,205 $15,626
P6500S-461 461 100 $14,205 $15,626
P6500S-479 479 100 $14,205 $15,626
P6500S-495 495 100 $14,205 $15,626
P6600S-515 515 100 $18,263 $20,091
P6600S-537 537 100 $18,263 $20,091
P6600S-559 559 100 $18,263 $20,091
P6600S-581 581 100 $18,263 $20,091
P6600S-603 603 6” 100 $18,263 $20,091
P6600S-625 625 [150] 100 $18,263 $20,091
P6600S-647 647 100 $18,263 $20,091
P6600S-669 669 100 $18,263 $20,091
P6600S-691 691 100 $18,263 $20,091
P6600S-713 713 100 $18,263 $20,091
*See flow reduction table in technical documentation.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

6-8
P6 Series Electronic Pressure Independent Valves
with Electronic Fail-Safe Actuators
2-way Valves with Stainless Steel Ball and Stem, Flanged Ends
Valve Specifications
chilled or hot water, up to 60% glycol
Service
max (open loop/steam not allowed)
Flow Characteristic equal percentage/linear
pattern to mate with ANSI 125
End Fitting
flange
Body cast iron - GG25
Sensor Housing ductile iron - GGG50
Ball stainless steel
Stem stainless steel
Seat Teflon® PTFE
Stem Packing EPDM
Media Temperature Range
14°F to 250°F [-10°C to +120°C]
(Water)
5 to 50 psid or 1 to 50 psid with
Differential Pressure Range
flow reductions*
Leakage 0%
Inlet Length to Meet
Specified Measurement 5X nominal pipe size (NPS)
Accuracy
Flow Sensor Technology electromagnetic
Power Supply for the Flow
sensor is powered by the actuator
Sensor

ACTUATOR PART # AKRX24-PI


Control Modulating
Manual Override •
Running Time (Motor) 90 seconds
Running Time (Fail-Safe) 35 seconds
Electrical Connection 3 ft, 18 GA plenum cable with ½” conduit connector
2-Way
Body Close-Off
Size
Model # GPM Pressure Pressure
[mm]
Rating [psi] [psi]
P6250S-080 80 100 $8,616
P6250S-085 85 100 $8,616
P6250S-090 90 100 $8,616
P6250S-100 100 100 $8,616
2½”
P6250S-105 105 100 $8,616
[65]
U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

P6250S-110 110 100 $8,616


P6250S-115 115 100 $8,616
P6250S-121 121 ANSI 125, 100 $8,616
Standard
P6250S-127 127 Class B 100 $8,616
P6300S-133 133 100 $10,936
All prices are in US Dollars (USD)

P6300S-141 141 100 $10,936


P6300S-149 149 100 $10,936
3”
P6300S-157 157 100 $10,936
[80]
P6300S-165 165 100 $10,936

ePIV
P6300S-173 173 100 $10,936
P6300S-180 180 100 $10,936
*See flow reduction table in technical documentation.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

6-9
P6 Series Electronic Pressure Independent Valves
with Electronic Fail-Safe Actuators
2-way Valves with Stainless Steel Ball and Stem, Flanged Ends
Valve Specifications
chilled or hot water, up to 60% glycol
Service
max (open loop/steam not allowed)
Flow Characteristic equal percentage/linear
pattern to mate with ANSI 125
End Fitting
flange
Body cast iron - GG25
Sensor Housing ductile iron - GGG50
Ball stainless steel
Stem stainless steel
Seat Teflon® PTFE
Stem Packing EPDM
Media Temperature Range
14°F to 250°F [-10°C to +120°C]
(Water)
5 to 50 psid or 1 to 50 psid with
Differential Pressure Range
flow reductions*
Leakage 0%
Inlet Length to Meet
Specified Measurement 5X nominal pipe size (NPS)
Accuracy
Flow Sensor Technology electromagnetic
Power Supply for the Flow
sensor is powered by the actuator
Sensor

ACTUATOR PART # GKRX24-PI


Control Modulating
Manual Override •
Running Time (Motor) 90 seconds
Running Time (Fail-Safe) 35 seconds
Electrical Connection 3 ft, 18 GA plenum cable with ½” conduit connector
2-Way
Body Close-Off
Size
Model # GPM Pressure Pressure
[mm]
Rating [psi] [psi]
P6400S-195 195 100 $12,533
P6400S-210 210 100 $12,533
P6400S-225 225 100 $12,533
P6400S-240 240 100 $12,533
4”
P6400S-255 255 100 $12,533
[100]

U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


P6400S-270 270 100 $12,533
P6400S-285 285 100 $12,533
P6400S-300 300 100 $12,533
P6400S-317 317 100 $12,533
P6500S-335 335 100 $15,237

All prices are in US Dollars (USD)


P6500S-353 353 100 $15,237
P6500S-371 371 100 $15,237
P6500S-389 389 100 $15,237
P6500S-407 407 5” ANSI 125, 100 $15,237
ePIV

P6500S-425 425 [125] Standard 100 $15,237


P6500S-443 443 Class B 100 $15,237
P6500S-461 461 100 $15,237
P6500S-479 479 100 $15,237
P6500S-495 495 100 $15,237
P6600S-515 515 100 $19,296
P6600S-537 537 100 $19,296
P6600S-559 559 100 $19,296
P6600S-581 581 100 $19,296
P6600S-603 603 6” 100 $19,296
P6600S-625 625 [150] 100 $19,296
P6600S-647 647 100 $19,296
P6600S-669 669 100 $19,296
P6600S-691 691 100 $19,296
P6600S-713 713 100 $19,296
*See flow reduction table in technical documentation.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

6-10
P6 Series Electronic Pressure Independent Valves
with Non Fail-Safe Actuators
2-way Valves with Stainless Steel Plug and Stem, ANSI 250 Flanged Ends
Valve Specifications
chilled or hot water, up to 60% glycol
Service
max (open loop/steam not allowed)
Flow Characteristic equal percentage/linear
pattern to mate with ANSI 250
End Fitting
flange
Body cast iron - GG25
Sensor Housing ductile iron - GGG50
Plug stainless steel
Stem stainless steel
Seat stainless steel
Stem Packing EPDM NLP (no lip packing)
Media Temperature Range
14°F to 250°F [-10°C to +120°C]
(Water)
7.5 to 50 psid or 1 to 50 psid with
Differential Pressure Range
flow reductions*
Leakage ANSI IV
Inlet Length to Meet
Specified Measurement 5X nominal pipe size (NPS)
Accuracy
Flow Sensor Technology electromagnetic
Power Supply for the Flow
sensor is powered by the actuator
Sensor

ACTUATOR PART # EVX24-PI-L EVX24-PI-B


Control Modulating Modulating
Manual Override • •
Running Time (Motor) 90 seconds 90 seconds
Electrical Connection 3 ft, 18 GA plenum cable with ½” conduit connector 3 ft, 18 GA plenum cable with ½” conduit connector
2-Way
Body
Close-Off
GPM Size Pressure
Model # Pressure
Range** [mm] Rating
[psi]
[psi]
P6250S-127-250 38-127 2½” [65] 310 $10,180
P6300S-180-250 54-180 3” [80] ANSI 250, 310 $12,494
P6400S-317-250 95-317 4”[100] Standard 310 $15,125
P6500S-495-250 149-495 5” [125] Class B 296 $19,974
P6600S-713-250 214-713 6” [150] 215 $24,373
U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

*See flow reduction table in technical documentation.


**Valve factory set to maximum flow. Field adjustable with supplied ZTH US
All prices are in US Dollars (USD)

ePIV

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

6-11
P6 Series Electronic Pressure Independent Valves
with Electronic Fail-Safe Actuators
2-way Valves with Stainless Steel Plug and Stem, ANSI 250 Flanged Ends
Valve Specifications
chilled or hot water, up to 60% glycol
Service
max (open loop/steam not allowed)
Flow Characteristic equal percentage/linear
pattern to mate with ANSI 250
End Fitting
flange
Body cast iron - GG25
Sensor Housing ductile iron - GGG50
Plug stainless steel
Stem stainless steel
Seat stainless steel
Stem Packing EPDM NLP (no lip packing)
Media Temperature Range
14°F to 250°F [-10°C to +120°C]
(Water)
7.5 to 50 psid or 1 to 50 psid with
Differential Pressure Range
flow reductions*
Leakage ANSI IV
Inlet Length to Meet
Specified Measurement 5X nominal pipe size (NPS)
Accuracy
Flow Sensor Technology electromagnetic
Power Supply for the Flow
sensor is powered by the actuator
Sensor

ACTUATOR PART # AVKX24-PI-L AVKX24-PI-B


Control Modulating Modulating
Manual Override • •
Running Time (Motor) 90 seconds 90 seconds
Running Time (Fail-Safe) 35 seconds 35 seconds
Electrical Connection 3 ft, 18 GA plenum cable with ½” conduit connector 3 ft, 18 GA plenum cable with ½” conduit connector
2-Way
Body
Close-Off
GPM Size Pressure
Model # Pressure
Range** [mm] Rating
[psi]
[psi]
P6250S-127-250 38-127 2½” [65] 310 $11,060
P6300S-180-250 54-180 3” [80] ANSI 250, 310 $13,373
P6400S-317-250 95-317 4”[100] Standard 290 $16,005
P6500S-495-250 149-495 5” [125] Class B

U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


202 $20,855
P6600S-713-250 214-713 6” [150] 135 $25,254
*See flow reduction table in technical documentation.
**Valve factory set to maximum flow. Field adjustable with supplied ZTH US

All prices are in US Dollars (USD)


ePIV

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

6-12
P6 Series Electronic Pressure Independent Valves
with with Non Fail-Safe Actuators and Fail-Safe Actuators
2-way Valves with Stainless Steel Ball and Stem, Flanged Ends ANSI 125
Valve Specifications
chilled or hot water, up to 60% glycol
Service
max (open loop/steam not allowed)
Flow Characteristic equal percentage/linear
pattern to mate with ANSI 125
End Fitting
flange
Body cast iron - GG25
Sensor Housing ductile iron - GGG50
Ball stainless steel
Stem stainless steel
Seat Teflon® PTFE
Stem Packing EPDM
Media Temperature Range
14°F to 250°F [-10°C to +120°C]
(Water)
5 to 50 psid or 1 to 50 psid with
Differential Pressure Range
flow reductions*
Leakage 0%
Inlet Length to Meet
Specified Measurement 5X nominal pipe size (NPS)
Accuracy
Flow Sensor Technology ultrasonic
Power Supply for the Flow
sensor is powered by the actuator
Sensor

ACTUATOR PART # ARX24-EP2 ARX24-EP2-MOD GRX24-EP2 GRX24-EP2-MOD AKRX24-EP2 GKRX24-EP2


Control Modulating Modulating Modulating Modulating Modulating Modulating
Manual Override • • • • • •
Running Time (Motor) 90 seconds 90 seconds 90 seconds 90 seconds 90 seconds 90 seconds
Running Time (Fail-Safe) 35 seconds 35 seconds
3 ft, 18 GA plenum 3 ft, 18 GA plenum 3 ft, 18 GA plenum 3 ft, 18 GA plenum 3 ft, 18 GA plenum 3 ft, 18 GA plenum
Electrical Connection cable with ½” conduit cable with ½” conduit cable with ½” conduit cable with ½” conduit cable with ½” conduit cable with ½” conduit
connector connector connector connector connector connector
ModBus & BACnet • •
Fail-Safe • •
2-Way
Body
Close-Off
Size Pressure
Model # GPM Pressure
[mm] Rating
[psi]
[psi]
U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

P6250SU-127 127 2½” [65] 100 $7,642 $8,406 $8,616

P6300SU-180 180 3” [80] 100 $9,914 $10,906 $10,936


ANSI 125,
P6400SU-317 317 4” [100] Standard 100 $11,499 $12,650 $12,533
All prices are in US Dollars (USD)

Class B
P6500SU-495 495 5” [125] 100 $14,205 $15,626 $15,237

P6600SU-713 713 6” [150] 100 $18,263 $20,091 $19,296

ePIV

*See flow reduction table in technical documentation.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

6-13
P6 Series Electronic Pressure Independent Valves
with with Non Fail-Safe Actuators and Fail-Safe Actuators
2-way Valves with Stainless Steel Ball and Stem, Flanged Ends ANSI 250
Valve Specifications
chilled or hot water, up to 60% glycol
Service
max (open loop/steam not allowed)
Flow Characteristic equal percentage/linear
pattern to mate with ANSI 250
End Fitting
flange
Body cast iron - GG25
Sensor Housing ductile iron - GGG50
Ball stainless steel
Stem stainless steel
Seat Teflon® PTFE
Stem Packing EPDM
Media Temperature Range
14°F to 250°F [-10°C to +120°C]
(Water)
5 to 50 psid or 1 to 50 psid with
Differential Pressure Range
flow reductions*
Leakage 0%
Inlet Length to Meet
Specified Measurement 5X nominal pipe size (NPS)
Accuracy
Flow Sensor Technology ultrasonic
Power Supply for the Flow
sensor is powered by the actuator
Sensor

ACTUATOR PART # ARX24-EP2 ARX24-EP2-MOD GRX24-EP2 GRX24-EP2-MOD AKRX24-EP2 GKRX24-EP2


Control Modulating Modulating Modulating Modulating Modulating Modulating
Manual Override • • • • • •
Running Time (Motor) 90 seconds 90 seconds 90 seconds 90 seconds 90 seconds 90 seconds
Running Time (Fail-Safe) 35 seconds 35 seconds
3 ft, 18 GA plenum 3 ft, 18 GA plenum 3 ft, 18 GA plenum 3 ft, 18 GA plenum 3 ft, 18 GA plenum 3 ft, 18 GA plenum
Electrical Connection cable with ½” conduit cable with ½” conduit cable with ½” conduit cable with ½” conduit cable with ½” conduit cable with ½” conduit
connector connector connector connector connector connector
ModBus & BACnet • •
Fail-Safe • •
2-Way
Body
Close-Off
Size Pressure
Model # GPM Pressure
[mm] Rating
[psi]
[psi]

U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


2½”
P6250SU-127-250 127 100 $10,180 $11,198 $11,060
[65]

3”
P6300SU-180-250 180 100 $12,494 $13,744 $13,373
[80]
ANSI 250,
4”

All prices are in US Dollars (USD)


P6400SU-317-250 317 Standard 100 $15,125 $16,638 $16,005
[100]
Class B
5”
P6500SU-495-250 495 100 $19,974 $21,972 $20,855
[125]
ePIV

6”
P6600SU-713-250 713 100 $24,373 $26,810 $25,254
[150]

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

6-14
6-Way Electronic Pressure Independent Valve Nomenclature

P3 050 B6 -K +LRX 24 -LP-EP6


Electronic Valve Size 6-Way Flow Actuator Type Power Supply Modulating Control
Pressure 050 = ½” Valve K = 5.5 GPM LRX 24 = 24 VAC/DC Control Input = 2-10 VDC
Independent 075 = ¾” J = 10.3 GPM Feedback = 2-10 VDC

Ordering Example

1 Choose the valve actuator combination.

P3050B6-K+LRX24-LP-EP6 NO Tagging (if needed)


3
2 Specify preference or configuration.
Does order
require
Set-Up tagging?

Non Fail-Safe Models Tagging:


NO = Normally Open - Sequence 1 Valves may be
-OR- tagged per customer
NC = Normally Closed - Sequence 1 specification. ($12.00
charge per tag)

Example:
Chilled/Heating Beam
Room #1

Part number for


tagging: 99981-00101
4 Complete Ordering Example: P3050B6-K+LRX24-LP-EP6
6-Way Electronic Pressure Independent Valve Product Range

Flow Valve Nominal Size Type Suitable Actuators


Vnom/GPM Inches DN [mm] ePI 6-way Non Fail-Safe

LRX24-LP-EP6
5.5 ½ 15 P3050B6-K

10.3 ¾ 20 P3075B6-J

Sequence 1 Sequence 2 ePIV


Linear Characteristic
Mode of Operation
The control valve is operated by an electronic actuator that
responds to a modulating 2-10 VDC control signal. The
To C
ply Supp
ly oil To C
oil
To C
oil
To C
oil Supp
ly
Supp
ly actuator will then move the ball of the valve to the position
dictated by the control signal and change the flow.

n to rn to
Retu e Retu Retu rn
Retu Coil rn Retu Retu Product Features
ce rn rn Retu Coil rn rn
Sourc Coil From Coil From From From Sourc To
e
Sourc To Linear characteristic, complete close-off.
e

Actuator Specifications
Control type modulating
Manual override LRX24-LP-EP6
Electrical connection 3 ft. [1 m] cable with
½” conduit fitting
Controllable flow range 90°
Communication BACnet MS/TP, Modbus RTU,
Analog

Valve Specifications
Service chilled or hot water, 60% glycol
Flow characteristic linear

U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


Controllable flow range
Sequence 1 (0 to 30º angle)
Dead zone 30º to 60º
Sequence 2 (60º to 90º angle)
Sizes ½”, ¾”
End fitting NPT

All prices are in US Dollars (USD)


Materials
Body nickel plated brass
Ball chrome plated brass
Stem nickel plated brass
ePIV

Seats Teflon® PTFE


Seat O-rings EPDM
Characterizing disc chrome plated steel
Stem O-rings EPDM
Media temperature range 43°F to 180ºF [6ºC to 82ºC]
Body pressure rating 232 psi
Close-off pressure 50 psi
Maximum differential
pressure (∆P) 15 psi
Leakage 0%
Rangeability 100:1
Flow control tolerance +6%
Flow measurement
tolerance +2%
All flow tolerances @ 68°F to 77°F [20°C to 25°C] and
0% glycol.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

6-16
6-Way Electronic Pressure Independent Valves
with Non Fail-Safe Actuators
Chrome Plated Ball and Nickel Plated Stem, NPT Female Ends
Valve Specifications
chilled or hot water, up to 60%
Service
glycol
Flow Characteristic linear
End Fitting NPT female ends
Body nickel plated brass
Ball chrome plated brass
Stem nickel plated brass
Seat Teflon® PTFE
O-ring EPDM
Characterized Disc chrome plated steel
Media Temperature Range 43°F to 180°F [6°C to 82°C]
Max Differential Pressure 15 psi
Leakage 0%

ACTUATOR PART # LRX24-LP-EP6


Control Modulating
Manual Override •
Running Time (Motor) 150 seconds (default), variable (35 to 150 seconds)
Modbus & BACnet •
Electrical Connection 3 ft, 18 GA plenum cable with ½” conduit connector

6-Way
Body
Flow Close-Off
Size Pressure
Model # Vnom/ Pressure
[mm] Rating
GPM [psi]
[psi]

½”
P3050B6-K 5.5 $1,463
[15]
232 50
¾”
P3075B6-J 10.3 $1,642
U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

[20]
All prices are in US Dollars (USD)

ePIV

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

6-17
Innovative Meets
Energy Efficient

Belimo 6-way Electronic Pressure Independent Valve (ePIV)


The 6-way ePIV with BACnet, Modbus, and Near Field Communication is the only one of its kind.
Designed for chilled beams, radiant ceiling panels, and 4-pipe fan coil units providing true flow
and dynamic balancing. It has the functionality of up to four 2-way control valves and two balancing
valves saving material and installation time. The valve is controlled by a single modulating actuator
that enables both heating/cooling to be controlled pressure independently from a single analog
control output. Simplified commissioning with flow measurement and verification.

Discover the advantages


www.belimo.us
7
BELIMO ZONETIGHT™
PRESSURE INDEPENDENT
ZONE VALVES (PIQCV)
Balancing and Control Valve
in One Compact Unit
• Smallest pressure independent characterized
ball valve in the market.
• Low power consumption up to 95% less
than conventional zone valves.
• Adjustable flow to meet design requirements.

Peter Schmidlin, Head of Innovation,


Member of the Executive Committee
ZoneTight Pressure Independent Zone Valve (PIQCV) Nomenclature

Z2 050 Q P T -B +CQB 24 -SR -R


Valve Type Valve Flow Rate Actuator Power Control Direction
Z2 = 2-way Size Quick Pressure T = PT Type Supply -3 = Floating of -S = Built
Port B = 0.9 GPM
ZoneTight 050 = ½” Connect Independent Non Fail- 24 = 24 VAC/DC Point Rotation -in
D = 2.0 GPM
Chrome 075 = ¾” Safe UP = 110-230 -SR = Modulating -L = Open Aux.
F = 4.3 GPM (2 VDC) Switch
Plated Brass CQB VAC
Ball and Brass G = 9.0 GPM CQX -R = Close
Stem (2 VDC)
Fail-Safe
-LL = Normally
CQKB
Open, Fail Open
CQKX
-RR =
Normally Close,
“X” models are customizable. Fail Close
Refer to page 7-3 for factory
set clip position options.
-LR =
Normally Open,
Fail Close
-RL =
Normally Close,
Fail Open

Ordering Example

Choose the valve actuator combination.


1
Z2050QPT-B+CQB24-SR -R Tagging or Setting
(if needed) 3 4
2 Choose set-up required. Does order Does order
require require
tagging? clip setting?
Set-Up

Modulating Non Fail-Safe Models Tagging: Clip Setting:


L = Normally Open Valves may be Valves may be set per
R = Normally Closed tagged per customer customer specification.
specification. ($12.00 (All clip settings
Fail-Safe Models charge per tag) excluding “N” [default
LL = Normally Open/Fail Open by factory] and “No Clip”
LR = Normally Open/Fail Closed Example: have a list price adder
AHU-1 of $37)
RL = Normally Closed/Fail Open FCU-2
Example:
RR = Normally Closed/Fail Closed
Part number for tagging: Clip Position 1
99981-00101 No Clip
Refers to valve ports from inlet to outlet, per flow arrow.
Part number for setting:
CQX, CQKX

5 Complete Ordering Example: Z2050QPT-B+CQB24-SR-R


ZoneTight Pressure Independent Zone Valve (PIQCV) Product Range

Valve Nominal Size Type Suitable Actuators

2-way NPT Non


GPM Inches DN [mm] Fail-Safe
with PT ports Fail-Safe

0.9* ½ 15 Z2050QPT-B

CQK Series
CQ Series
2.0* ½ 15 Z2050QPT-D
4.3* ½ 15 Z2050QPT-F
9.0* ¾ 20 Z2075QPT-G
*Maximum flow value can be field adjusted, see actuator instructions.
Order “X” model actuators for Factory Clip Setting, see instruction manual for details.
PIQCV

Mode of Operation
The ZoneTight Pressure Independent Zone Valve (PIQCV) is a
two-way valve which combines the functionality of a control valve
Clip Position for Flow Adjustment (GPM) and a pressure regulating valve, creating one precise product which
is unaffected by pressure variations in a system.
1 2 3 4 5 6 N No Clip
Product Features
Z2050QPT-B (½”) N/A N/A N/A N/A 0.4 N/A 0.8 0.9 Provides constant flow regardless of pressure variations in the
system. Simplified valve sizing and selection, no Cv calculations
Z2050QPT-D (½”) 0.2 0.3 0.4 0.6 0.9 1.3 1.8 2.0 required.

Z2050QPT-F (½”) N/A 0.6 0.8 1.3 1.9 2.8 3.6 4.3 Actuator Specifications
Control type
Z2075QPT-G (¾”) N/A 1.8 2.7 3.7 4.9 6.3 7.7 9.0 -3 on/off, floating point
-SR modulating, 0.5-10 VDC*, 2-10 VDC
Actuator Runtime 30 sec. 37 sec. 43 sec. 49 sec. 55 sec. 62 sec. 68 sec. 75 sec.
Manual override use actuator to turn valve stem
For additional intermediate settings see technical documentation or the ZoneTight flow capacity setting tool Electrical connection 3 ft. [1 m] cable with ½” conduit fitting
on www.belimo.us. screw terminals
Power consumption
CQ.. 0.3 W running, 0.2 W holding
CQK.. 2.5 W running, 0.5 W holding
CQ..UP 1 W running, 0.7 W holding
Power supply 24V (110-240 VAC, UP)
Transformer sizing
CQ.. 0.6 VA
U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

CQK.. 5 VA
CQ..UP 2 VA

Valve Specifications
Service chilled or hot water, 60% glycol
All prices are in US Dollars (USD)

Flow characteristic equal percentage


Controllable flow range 75°
Sizes ½”, ¾”
End fitting NPT female
Materials
Body forged brass
Ball stainless steel
Stem stainless steel
Seats Teflon® PTFE
O-rings EPDM
Spring stainless steel
Media temp. range 36°F to 212°F [2°C to 100°C]**
Media temp. limit 250°F [120°C]**
Maximum allowable
operating temperature 212°F [100°C]**
PT ports 2
Body pressure rating 360 psi
Close-off pressure 200 psi
Differential pressure
(∆P) range 5 to 50 psi
Leakage 0%
Flow control tolerance ±5%

*Specify upon ordering.


**If temperature exceeds 212°F [100°C] operating range due to a
boiler control failure the valve will safely contain the hot water but
manufacturer’s product warranty becomes invalid.

7-3
ZoneTight Pressure Independent Zone Valves (PIQCV)

SET-UP- Specify Upon Ordering

2-WAY VALVES

CQB(X)UP-3 On/Off: Power to brown wire (pin 2) will drive valve CW (closed).
Power to brown wire (pin 3) and white wire (pin 3) will drive valve
CCW (open).

Floating: Power to brown wire (pin 2) will drive valve CW (closed).


Power to white wire (pin 3) will drive valve CCW (open).
Stays in Last Position
NON FAIL-SAFE

CQB(X)24-3 On/Off: Power to red wire (pin 2) will drive valve CW (closed).
Power to red wire (pin 2) and white wire (pin 3) will drive valve
CCW (open).

Floating: Power to red wire (pin 2) will drive valve CW (closed).


Power to white wire (pin 3) will drive valve CCW (open).

CQB(X)24-SR CQB24-SR-R: Normally closed, CQB24-SR-L: Normally open,


valve will open as voltage valve will close as voltage
increases increases

CQKB(X)24 CQKB24-LL, CQKB24-S-LL: CQKB24-RR, CQKB24-S-RR:


CQKB(X)24-S Normally open CCW, valve will Normally closed CW, valve will
drive closed when energized. drive open when energized.
Fail-Safe Action: Actuator will Fail-Safe Action: Actuator will
ELECTRONIC FAIL-SAFE

fail open CCW upon power loss. fail closed CW upon power loss.

CQKB(X)24-SR CQKB24-SR-RL: Normally CQKB24-SR-RR: Normally


closed CW, valve will open closed CW, valve will open
as voltage increases. as voltage increases.
Fail-Safe Action: Will fail Fail-Safe Action: Will fail
open upon power loss. closed upon power loss.

U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


CQKB24-SR-LL: Normally open CQKB24-SR-LR: Normally open
CCW, valve will close as voltage CCW, valve will close as voltage
increases. increases.

All prices are in US Dollars (USD)


Fail-Safe Action: Will fail open Fail-Safe Action: Will fail closed
upon power loss. upon power loss.

Note: One wire control for CW or CCW rotation.


PIQCV

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

7-4
ZoneTight Pressure Independent Zone Valves (PIQCV)
Operation and Installation

FLOW PATTERN
ZoneTight Pressure Independent Zone Valve (PIQCV)
consists of a differential pressure regulator in series
with a control valve.
The control valve is throttled to match the flow command of
the control signal. The differential pressure regulator holds
the pressure drop across the ball of the valve. As system
pressures change, the differential pressure regulator moves in
response to keep the flow stable.

Pressure P1 at the inlet of the ZoneTight Pressure


Independent Zone Valve (PIQCV) is high and pressure P3 at
the outlet is low. The differential pressure between P1 and P3
must be between 5-50 PSI to achieve pressure independent
flow. When differential pressure increases the regulator
opening is reduced. When differential pressure decreases the
regulator opening is increased. This allows for the constant
pressure differential across the ball of the valve.

INSTALLATION
ZoneTight Pressure Independent Zone Valves (PIQCV) should
360°
be installed with flow in the direction of the arrow on the valve
body. If installed backwards, there could be damage to either the
diaphragm or the regulator.
The valve assembly can be installed in a vertical or horizontal
arrangement, as long as the actuator is positioned to avoid
condensation from dripping on the actuator.

90°
U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

90°
All prices are in US Dollars (USD)

PIPING
ZoneTight Pressure Independent Zone Valves (PIQCV) are recommended to be installed on the return side of the coil. This diagram is for typical applications only.
Consult engineering specification and drawings for particular circumstances. PT ports are recommended on the supply side of the heat transfer device to allow for
coil pressure/temperature measurements and calculation of flow. Refer to ZoneTight Pressure Independent Zone Valve (PIQCV) technical documentation for flow
verification and commissioning procedures.
BELIMO PIQCV (TYP.)

H/C–COIL FLOW FLOW

AIR VENT SHUT–OFF


VALVE
PIQCV

UNION CONNECTION (TYP.)

FLOW
P/T PORT FLOW STRAINER FLOW SHUT–OFF
(Optional) VALVE
DRAIN

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

7-5
TYPICAL PARALLEL PIPING IN RELATION
ZoneTight Pressure Independent Zone Valves (PIQCV)
with Non Fail-Safe Actuators
2-way Valve with NPT Female Ends
Valve Specifications
Service chilled, hot water, up to 60% glycol
Flow Characteristic equal percentage
Controllable Flow Range 75°
End Fitting NPT female
Body forged brass
Ball stainless steel
Stem stainless steel
Seat Teflon® PTFE
Characterization incorporated into the ball
Media Temperature Limit 250°F [120°C]*
Differential Pressure Range 5 to 50 psi
Maximum Allowable
212°F [100°C]*
Operating Temperature
Leakage 0%

ACTUATOR PART # CQB24-3 CQB24-SR-L CQB24-SR-R CQBUP-3


Control On/Off, Floating Point Modulating, 2-10 VDC Modulating, 2-10 VDC On/Off, Floating Point
Power Supply 24 VAC/DC 24 VAC/DC 24 VAC/DC 110-230 VAC
Set-Up NO NC
Running Time (Motor) 75 seconds (0-90°) 75 seconds (0-90°) 75 seconds (0-90°) 75 seconds (0-90°)
3 ft, 18 GA plenum cable with 3 ft, 18 GA plenum cable with 3 ft, 18 GA plenum cable with 3 ft, 18 GA plenum cable with
Electrical Connection
½” conduit connector ½” conduit connector ½” conduit connector ½” conduit connector
2-Way with PT Ports
Body
Close-Off
Size Pressure
Model # GPM Pressure
[mm] Rating
[psi]
[psi]
Z2050QPT-B 0.9 200 $404 $477 $477 $418
Z2050QPT-D 2.0 ½” [15] 200 $404 $477 $477 $418
360
Z2050QPT-F 4.3 200 $427 $500 $500 $443
Z2075QPT-G 9 ¾” [20] 200 $575 $649 $649 $591

* If temperature exceeds 212°F [100°C] operating range due to a boiler control failure the valve will safely contain the hot water but manufacturer’s product warranty becomes invalid.

U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


ACTUATOR PART # CQX24-3 CQX24-SR-L CQX24-SR-R CQXUP-3
Add to List Price for Factory Clip Setting +$37 +$37 +$37 +$37

All prices are in US Dollars (USD)


PIQCV

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

7-6
ZoneTight Pressure Independent Zone Valves (PIQCV)
with Electronic Fail-Safe Actuators
2-way Valve with NPT Female Ends, PT Ports
Valve Specifications
Service chilled, hot water, up to 60% glycol
Flow Characteristic equal percentage
Controllable Flow Range 75°
End Fitting NPT female
Body forged brass
Ball stainless steel
Stem stainless steel
Seat Teflon® PTFE
Characterization incorporated into the ball
Media Temperature Limit 250°F [120°C]*
Differential Pressure Range 5 to 50 psi
Maximum Allowable
212°F [100°C]*
Operating Temperature
Leakage 0%

ON/OFF
ACTUATOR PART # CQKB24-LL CQKB24-RR CQKB24-S-LL CQKB24-S-RR
Control On/Off On/Off On/Off On/Off
Power Supply 24 VAC/DC 24 VAC/DC 24 VAC/DC 24 VAC/DC
Set-Up NO/FO NC/FC NO/FO NC/FC
Running Time (Motor) 75 seconds (0-90°) 75 seconds (0-90°) 75 seconds (0-90°) 75 seconds (0-90°)
Running Time (Fail-Safe) 60 seconds 60 seconds 60 seconds 60 seconds
3 ft, 18 GA plenum cable with 3 ft, 18 GA plenum cable with 3 ft, 18 GA plenum cable with 3 ft, 18 GA plenum cable with
Electrical Connection
½” conduit connector ½” conduit connector ½” conduit connector ½” conduit connector
Auxiliary Switch 1 SPST 1 SPST
2-Way
Body
Close-Off
Size Pressure
Model # GPM Pressure
[mm] Rating
[psi]
[psi]
Z2050QPT-B 0.9 200 $397 $397 $417 $417
Z2050QPT-D 2.0 ½” [15] 200 $397 $397 $417 $417
360
Z2050QPT-F 4.3 200 $418 $418 $440 $440
Z2075QPT-G 9 ¾” [20] 200 $570 $570 $589 $589

ACTUATOR PART # CQKX24-LL CQKX24-RR CQKX24-S-LL CQKX24-S-RR


Add to List Price for Factory Clip Setting +$37 +$37 +$37 +$37
U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.
All prices are in US Dollars (USD)

MODULATING
ACTUATOR PART # CQKB24-SR-LL CQKB24-SR-LR CQKB24-SR-RL CQKB24-SR-RR
Control Modulating, 2-10 VDC Modulating, 2-10 VDC Modulating, 2-10 VDC Modulating, 2-10 VDC
Power Supply 24 VAC/DC 24 VAC/DC 24 VAC/DC 24 VAC/DC
Set-Up NO/FO NO/FC NC/FO NC/FC
Running Time (Motor) 75 seconds (0-90°) 75 seconds (0-90°) 75 seconds (0-90°) 75 seconds (0-90°)
Running Time (Fail-Safe) 60 seconds 60 seconds 60 seconds 60 seconds

3 ft, 18 GA plenum cable with 3 ft, 18 GA plenum cable with 3 ft, 18 GA plenum cable with 3 ft, 18 GA plenum cable with
Electrical Connection
½” conduit connector ½” conduit connector ½” conduit connector ½” conduit connector

2-Way
Body
Close-Off
PIQCV

Size Pressure
Model # GPM Pressure
[mm] Rating
[psi]
[psi]
Z2050QPT-B 0.9 200 $500 $500 $500 $500
Z2050QPT-D 2.0 ½” [15] 200 $500 $500 $500 $500
360
Z2050QPT-F 4.3 200 $522 $522 $522 $522
Z2075QPT-G 9 ¾” [20] 200 $611 $611 $611 $611

* If temperature exceeds 212°F [100°C] operating range due to a boiler control failure the valve will safely contain the hot water but manufacturer’s product warranty becomes invalid.

ACTUATOR PART # CQKX24-SR-LL CQKX24-SR-LR CQKX24-SR-RL CQKX24-SR-RR


Add to List Price for Factory Clip Setting +$37 +$37 +$37 +$37

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

7-7
Efficient in
Every Way

U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


All prices are in US Dollars (USD)
Belimo ZoneTight™ Zone Valves
Belimo zone valve product range sets new design and performance standards for both
pressure dependent and pressure independent zoning applications. Designed for maximum
efficiency in tight spaces the QCV and PIQCV zone valve ball design offers zero leakage,
ensures tight closing to eliminate energy losses and is resistant to clogging. The Belimo
brushless DC motor technology consumes 95% less energy than conventional zone valves.
In addition to significantly reducing energy costs, the Cv and or GPM can be adjusted in the
field to meet to design needs.

Discover the advantages


www.belimo.us
ZONETIGHT ZONE VALVES
BELIMO ZONETIGHT™
ZONE VALVES
(QCV & 6-WAY)
Efficient in Every Way
• Compact design for maximum efficiency in
tight spaces.
• Up to 95% less power consumption than
conventional zone valves.
• Ball valve design with zero leakage
eliminates energy loss.

Michael LeBlanc, Vice President, General Manager Canada


A Quick and
Efficient Way to
Adjust Cv/GPM
ZONETIGHT ZONE VALVES

Belimo Flow Capacity Application Tool


Belimo ZoneTight™ Zone Valves offer you the option to field adjust to the desired flow to meet
system design requirements. Using the online Flow Capacity Tool, simply select the valve
model, enter your design parameters and click submit. Your valve settings are shown. It is
that easy.

Access the Flow Capacity Tool online at www.belimo.us

Discover the advantages


www.belimo.us
8
BELIMO ZONETIGHT™
ZONE VALVES (QCV)
Space Saving Zone Valves
• Belimo ball valve design offers zero leakage,
ensures tight closing eliminating energy
losses, and is resistant to clogging.
• Low power consumption up to 95% less
than conventional zone valves.
• Adjustable Cv value to meet design
requirements.

Kumar Prashant, SAP Solutions Architect


ZoneTight Zone Valve (QCV) Nomenclature

Z2 050 Q S -J +CQB 24 -SR -L


Valve Type Valve Connection Cv Actuator Power Supply Control Direction of
Z2 = 2-way Size Quick Type Type 24 = 24 VAC/DC -3 = On/Off, Rotation -S = Built-in
2-way
Z3 = 3-way 050 = ½” Connect Blank = NPT Non Fail- UP = 100-240 VAC Floating Point -L = Open (2 VDC) Aux.
F = 1.4 Switch
ZoneTight 075 = ¾” S = Sweat Safe -SR = Modulating -R = Close (2 VDC)
J = 5.9 CQB Input = 2-10 VDC -LL = Normally
Chrome Plated
Brass Ball and K = 9.8 CQX Open, Fail Open
Brass Stem 3-way* Electronic -RR = Normally
Close, Fail Close
E = 1 Fail-Safe
-LR = Normally
H = 2.7 CQKB Open, Fail Close
CQKX
J = 4.6 -RL = Normally
Close, Fail Open
“X” models are customizable.
Refer to page 8-3 for factory
set clip position options.

*On/off only.

Ordering Example

Choose the valve actuator combination.


1
Z2050QS-J+CQB24-SR -L Tagging or Setting
(if needed) 3 4
2 Choose set-up required Does order Does order
require require
tagging? clip setting?
Set-Up

Modulating Non Fail-Safe Models Tagging: Clip Setting:


L = Normally Open Valves may be Valves may be set per
R = Normally Closed tagged per customer customer specification.
specification. ($12.00 (All clip settings
Fail-Safe Models charge per tag) excluding “N” [default
LL = Normally Open/Fail Open by factory] and “No Clip”
Example:
LR = Normally Open/Fail Closed have a list price adder
AHU-1
of $37)
FCU-2
RL = Normally Closed/Fail Open Example:
RR = Normally Closed/Fail Closed Clip Position 1
Part number for tagging:
99981-00101 No Clip
Refers to valve ports from inlet to outlet,
per flow arrow. Part number for setting:
CQX, CQKX

5 Complete Ordering Example: Z2050QS-J+CQB24-SR-L


ZoneTight Zone Valve (QCV) Product Range

Valve Nominal Size Type Suitable Actuators

Non
Cv Inches DN [mm] 2-way 3-way Fail-Safe
Fail-Safe

1.4* ½ 15 Z2050Q-F
5.9* ½ 15 Z2050Q-J
9.8* ¾ 20 Z2075Q-K
NPT

1 ½ 15 Z3050Q-E
2.7 ½ 15 Z3050Q-H

CQK Series
QCV

CQ Series
4.6 ¾ 20 Z3075Q-J
1.4* ½ 15 Z2050QS-F
5.9* ½ 15 Z2050QS-J
9.8* ¾ 20 Z2075QS-K
Sweat

Mode of Operation
1 ½ 15 Z3050QS-E The ZoneTight Zone Valve (QCV) is operated by a rotary actuator.
The actuators are controlled by a standard voltage for on/off control,
2.7 ½ 15 Z3050QS-H a modulating signal, or 3-point control system which moves the ball
of the valve to the position dictated by the control system.
4.6 ¾ 20 Z3075QS-J
Product Features
*Maximum flow. Max value can be field adjusted, see actuator instructions.
The equal percentage characteristic of the flow is ensured by
Order “X” model Actuators for Factory Clip Setting, see Instruction Manual for details.
the design of the ball. This characteristic provides linear heating
or cooling output from the coil improving energy efficiency and
comfort.

Clip Position for Flow Adjustment No Clip Actuator Specifications


Control type
No end -3 on/off, floating point
1 2 3- 3 4 4+ 5 5+ 6 N
stop -SR modulating, 2-10 VDC
Z2050Q(S)-F ( ½”) 0.1 N/A 0.2 N/A N/A 0.4 N/A 0.6 0.8 1.2 1.4 Manual override use actuator to turn valve stem
Electrical connection 3 ft. [1 m] cable with ½” conduit fitting
Z2050Q(S)-J (½”) 0.5 0.7 N/A 1.2 1.7 N/A 2.4 N/A 3.4 4.8 5.9 screw terminals
Power consumption
Z2075Q(S)-K (¾”) 0.5 1.0 N/A 1.5 2.3 N/A 3.3 N/A 4.6 6.6 9.8 CQ.. 0.3 W running, 0.2 W holding
CQK.. 2.5 W running, 0.5 W holding
CQ..UP 1.0 W running, 0.7 W holding
Power supply 24 VAC/DC (100-240 VAC, UP)
Transformer sizing
U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

CQ.. 0.6 VA
CQK.. 5 VA
CQ..UP 2 VA

Valve Specifications
Service chilled or hot water, 60% glycol
All prices are in US Dollars (USD)

Flow characteristic equal percentage (2-way)


linear (3-way)
Controllable flow range 75° (2-way), 90° (3-way)
Sizes ½”, ¾”
End fitting NPT female
sweat
Materials
Body forged brass
Ball chrome plated brass
Stem brass
Seats Teflon® PTFE
O-rings EPDM (lubricated)
Media temp. range 36°F to 212°F [2°C to 100°C]
Media temp. limit 250°F [120°C]
Maximum allowable
operating temperature 212°F [100°C]
Body pressure rating 360 psi
Close-off pressure 75 psi
Maximum differential
pressure (∆P) 40 psi
Leakage 0%
Teflon® is a registered trademark of DuPont™

If temperature exceeds 212°F [100°C] operating range due to a


boiler control failure the valve will safely contain the hot water but
manufacturer’s product warranty becomes invalid.

8-3
ZoneTight Zone Valves (QCV)
Set-Up

SET-UP- Specify Upon Ordering

2-WAY AND 3-WAY VALVES

CQB(X)UP-3 On/Off: Power to brown wire (pin 2) will drive valve CW (closed).
Power to brown wire (pin 3) and white wire (pin 3) will drive valve
CCW (open).

Floating: Power to brown wire (pin 2) will drive valve CW (closed).


Power to white wire (pin 3) will drive valve CCW (open).
Stays in Last Position
NON FAIL-SAFE

CQB(X)24-3 On/Off: Power to red wire (pin 2) will drive valve CW (closed). Power
to red wire (pin 2) and white wire (pin 3) will drive valve CCW (open).

Floating: Power to red wire (pin 2) will drive valve CW (closed). Power
to white wire (pin 3) will drive valve CCW (open).

CQB(X)24-SR CQB24-SR-R: Normally closed, CQB24-SR-L: Normally open,


valve will open as voltage valve will close as voltage
increases. increases.

CQKB(X)24 CQKB24-LL, CQKB24-S-LL: CQKB24-RR, CQKB24-S-RR:


CQKB(X)24-S Normally open CCW, valve will Normally closed CW, valve will
drive closed when energized. drive open when energized.
Fail-Safe Action: Actuator will fail Fail-Safe Action: Actuator will fail
ELECTRONIC FAIL-SAFE

open CCW upon power loss. closed CW upon power loss.

CQKB(X)24-SR CQKB24-SR-RL: Normally CQKB24-SR-RR: Normally closed


closed CW, valve will open CW, valve will open
as voltage increases. as voltage increases.
Fail-Safe Action: Will fail Fail-Safe Action: Will fail
open upon power loss. closed upon power loss.

U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


CQKB24-SR-LL: Normally open CQKB24-SR-LR: Normally open
CCW, valve will close as voltage CCW, valve will close as voltage
increases. increases.

All prices are in US Dollars (USD)


Fail-Safe Action: Will fail open Fail-Safe Action: Will fail closed
upon power loss. upon power loss.

Note: One wire control for CW or CCW rotation.


QCV

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

8-4
C3..Q..

!
ZoneTight Zone Valves (QCV)
Y1 Y2

Flow Pattern and Piping

FLOW PATTERN C3..Q..

! Y1 Y2

Y1 Y2
90° AB 90° AB

Y1 Y2
90° 90°

PIPING DIAGRAMS
Y1 Y2
90° 90°
2-way Valve Piping Diagram
3-way Switching Valve Piping Diagram

3-way Switching Valve Piping Diagram 3-way Diverting Valve Piping Diagram
3-way Switching Valve Piping Diagram 3-way Diverting Valve Piping Diagram
2
www.belimo.com

www.belimo.com

1
U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

PIPING/MOUNTING ORIENTATION & INSULATION


3-way Diverting Valve Piping Diagram 2
All prices are in US Dollars (USD)

3-way Diverting Valve Piping Diagram


click
www.belimo.com !
90° 90° kg

1
3

!
3-way Diverting Valve Piping Diagram
kg
QCV

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

8-5
ZoneTight Zone Valves (QCV) with Non Fail-Safe Actuators
2-way and 3-way Valves with NPT Female Ends and Sweat Connection

Valve Specifications
Service chilled , hot water, 60% glycol
equal percentage (2-way)
Flow Characteristic
linear (3-way)
75° (2-way)
Controllable Flow Range
90° (3-way)
NPT female
End Fitting
sweat
Body forged brass
Ball chrome plated brass
Stem brass
Seat Teflon® PTFE
Media Temperature Limit 250°F [120°C]*
Max Differential Pressure
40 psi
(Water)
Maximum Allowable
212°F [100°C]*
Operating Temperature
Leakage 0%

ACTUATOR PART # CQB24-3 CQB24-SR-L CQB24-SR-R CQBUP-3


Control On/Off, Floating Point Modulating, 2-10 VDC Modulating, 2-10 VDC On/Off, Floating Point
Power Supply 24 VAC/DC 24 VAC/DC 24 VAC/DC 100-230 VAC
Set-Up NO NC
Running Time (Motor) 75 seconds (0°-90°) 75 seconds (0°-90°) 75 seconds (0°-90°) 75 seconds (0°-90°)
3 ft, 18 GA plenum cable with 3 ft, 18 GA plenum cable with 3 ft, 18 GA plenum cable with 3 ft, 18 GA plenum cable with
Electrical Connection
½” conduit connector ½” conduit connector ½” conduit connector ½” conduit connector
2-Way NPT
Body
Close-Off
Size Pressure
Model # Cv Pressure
[mm] Rating
[psi]
[psi]
Z2050Q-F** 1.4 $198 $271 $271 $214
½” [15]
Z2050Q-J** 5.9 360 75 $198 $271 $271 $214
Z2075Q-K** 9.8 ¾” [20] $222 $293 $293 $236
3-Way NPT (On/Off Only)
Z3050Q-E 1 $222 $236
½” [15]
Z3050Q-H 2.7 360 40 $222 $236
Z3075Q-J 4.6 ¾” [20] $244 $259

U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


2-Way Sweat
Body
Close-Off
Size Pressure
Model # Cv Pressure
[mm] Rating
[psi]
[psi]

All prices are in US Dollars (USD)


Z2050QS-F** 1.4 $198 $271 $271 $214
½” [15]
Z2050QS-J** 5.9 360 75 $198 $271 $271 $214
Z2075QS-K** 9.8 ¾” [20] $222 $293 $293 $236
3-Way Sweat (On/Off Only)
Z3050QS-E 1 $222 $236
½” [15]
Z3050QS-H 2.7 360 40 $222 $236
Z3075QS-J 4.6 ¾” [20] $244 $259

* If temperature exceeds 212°F [100°C] operating range due to a boiler control failure the valve will safely contain the hot water but manufacturers product warranty becomes invalid.
** Maximum flow. Max value can be field adjusted, see actuator instructions.

ACTUATOR PART # CQX24-3 CQX24-SR-L CQX24-SR-R CQXUP-3


Add to List Price for Factory Clip Setting +$37 +$37 +$37 +$37
QCV

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

8-6
ZoneTight Zone Valves (QCV) with Electronic Fail-Safe Actuators
2-way and 3-way Valves with NPT Female Ends and Sweat Connection

Valve Specifications
Service chilled , hot water, 60% glycol
equal percentage (2-way)
Flow Characteristic
linear (3-way)
75° (2-way)
Controllable Flow Range
90° (3-way)
NPT female
End Fitting
sweat
Body forged brass
Ball chrome plated brass
Stem brass
Seat Teflon® PTFE
Media Temperature Limit 250°F [120°C]*
Max Differential Pressure
40 psi
(Water)
Maximum Allowable
212°F [100°C]*
Operating Temperature
Leakage 0%

ON/OFF
ACTUATOR PART # CQKB24-LL CQKB24-RR CQKB24-S-LL CQKB24-S-RR

Control On/Off On/Off On/Off On/Off


Power Supply 24 VAC/DC 24 VAC/DC 24 VAC/DC 24 VAC/DC
Set-Up NO/FO NC/FC NO/FO NC/FC
Running Time (Motor) 75 seconds (0°-90°) 75 seconds (0°-90°) 75 seconds (0°-90°) 75 seconds (0°-90°)
Running Time (Fail-Safe) 60 seconds 60 seconds 60 seconds 60 seconds
3 ft, 18 GA plenum cable with 3 ft, 18 GA plenum cable with 3 ft, 18 GA plenum cable with ½” 3 ft, 18 GA plenum cable with
Electrical Connection
½” conduit connector ½” conduit connector conduit connector ½” conduit connector
Auxiliary Switch 1 SPST 1 SPST
2-Way NPT
Body
Close-Off
Size Pressure
Model # Cv Pressure
[mm] Rating
[psi]
[psi]
Z2050Q-F** 1.4 $191 $191 $212 $212
½” [15]
Z2050Q-J** 5.9 360 75 $191 $191 $212 $212
Z2075Q-K** 9.8 ¾” [20] $214 $214 $235 $235
3-Way NPT
Z3050Q-E 1 $214 $214 $235 $235
U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

½” [15]
Z3050Q-H 2.7 360 40 $214 $214 $235 $235
Z3075Q-J 4.6 ¾” [20] $236 $236 $257 $257

2-Way Sweat
All prices are in US Dollars (USD)

Body
Close-Off
Size Pressure
Model # Cv Pressure
[mm] Rating
[psi]
[psi]
Z2050QS-F** 1.4 $191 $191 $212 $212
½” [15]
Z2050QS-J** 5.9 360 75 $191 $191 $212 $212
Z2075QS-K** 9.8 ¾” [20] $214 $214 $235 $235
3-Way Sweat
Z3050QS-E 1 $214 $214 $235 $235
½” [15]
Z3050QS-H 2.7 360 40 $214 $214 $235 $235
Z3075QS-J 4.6 ¾” [20] $236 $236 $257 $257

* If temperature exceeds 212°F [100°C] operating range due to a boiler control failure the valve will safely contain the hot water but manufacturers product warranty becomes invalid.
** Maximum flow. Max value can be field adjusted, see actuator instructions.

ACTUATOR PART # CQKX24-LL CQKX24-RR CQKX24-S-LL CQKX24-S-RR


Add to List Price for Factory Clip Setting +$37 +$37 +$37 +$37
QCV

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

8-7
ZoneTight Zone Valves (QCV) with Electronic Fail-Safe Actuators
2-way Valves with NPT Female Ends and Sweat Connection

Valve Specifications
Service chilled , hot water, 60% glycol
Flow Characteristic equal percentage
Controllable Flow Range 75°
NPT female
End Fitting
sweat
Body forged brass
Ball chrome plated brass
Stem brass
Seat Teflon® PTFE
Media Temperature Limit 250°F [120°C]*
Max Differential Pressure
40 psi
(Water)
Maximum Allowable
212°F [100°C]*
Operating Temperature
Leakage 0%

MODULATING
ACTUATOR PART # CQKB24-SR-LL CQKB24-SR-LR CQKB24-SR-RL CQKB24-SR-RR

Control Modulating, 2-10 VDC Modulating, 2-10 VDC Modulating, 2-10 VDC Modulating, 2-10 VDC
Power Supply 24 VAC/DC 24 VAC/DC 24 VAC/DC 24 VAC/DC
Set-Up NO/FO NO/FC NC/FO NC/FC
Running Time (Motor) 75 seconds (0°-90°) 75 seconds (0°-90°) 75 seconds (0°-90°) 75 seconds (0°-90°)
Running Time (Fail-Safe) 60 seconds 60 seconds 60 seconds 60 seconds

3 ft, 18 GA plenum cable with 3 ft, 18 GA plenum cable with 3 ft, 18 GA plenum cable with 3 ft, 18 GA plenum cable with
Electrical Connection
½” conduit connector ½” conduit connector ½” conduit connector ½” conduit connector

2-Way NPT
Body
Close-Off
Size Pressure
Model # Cv Pressure
[mm] Rating
[psi]
[psi]
Z2050Q-F** 1.4 $292 $292 $292 $292
½” [15]
Z2050Q-J** 5.9 360 75 $292 $292 $292 $292
Z2075Q-K** 9.8 ¾” [20] $316 $316 $316 $316

2-Way Sweat
Body

U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


Close-Off
Size Pressure
Model # Cv Pressure
[mm] Rating
[psi]
[psi]
Z2050QS-F** 1.4 $292 $292 $292 $292
½” [15]
Z2050QS-J** 5.9 360 75 $292 $292 $292 $292

All prices are in US Dollars (USD)


Z2075QS-K** 9.8 ¾” [20] $316 $316 $316 $316

* If temperature exceeds 212°F [100°C] operating range due to a boiler control failure the valve will safely contain the hot water but manufacturers product warranty becomes invalid.
** Maximum flow. Max value can be field adjusted, see actuator instructions.

ACTUATOR PART # CQKX24-SR-LL CQKX24-SR-LR CQKX24-SR-RL CQKX24-SR-RR


Add to List Price for Factory Clip Setting +$37 +$37 +$37 +$37
QCV

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

8-8
9
6-WAY CHARACTERIZED
CONTROL VALVES
Efficient Way to Control Both
Heating and Cooling
• True close-off to isolate both heating and
cooling loops.
• Replaces four 2-way valves drastically
simplifying installation.
• Only one actuator to integrate and wire.

Gina Bendlin, Talent Acquisition Specialist


6-Way Characterized Control Valve Nomenclature

B3 15 -029 - 029 +LRB 24 -SR


Valve Valve Size Sequence 1 Sequence 2 Actuator Type Power Supply Control
B3 = 3-way 15 = ½” 029 = 0.29 Cv Two 3-way 029 = 0.29 Cv LRB, LRX 24 = 24 VAC/VDC -SR = 2-10 VDC
20 = ¾” 046 = 0.46 Cv = 6-way 046 = 0.46 Cv NRB, NRX -MFT = Multi-Function
25 = 1” 073 = 0.73 Cv 073 = 0.73 Cv Technology
116 = 1.16 Cv 116 = 1.16 Cv Feedback = 2-10 VDC
150 = 1.50 Cv 150 = 1.50 Cv
175 = 1.75 Cv 175 = 1.75 Cv
186 = 1.86 Cv 186 = 1.86 Cv
200 = 2.00 Cv 200 = 2.00 Cv
290 = 2.90 Cv 290 = 2.90 Cv
400 = 4.00 Cv 400 = 4.00 Cv
490 = 4.90 Cv 470 = 4.70 Cv
740 = 7.40 Cv 700 = 7.00 Cv

Ordering Example

1 Choose the valve actuator combination.

B315-029-029+LRB24-SR NO Tagging (if needed)


3
2 Specify preference or configuration.
Does order
require
Set-Up tagging?

Non Fail-Safe Models Tagging:


NO = Normally Open - Sequence 1 Valves may be
-OR- tagged per customer
NC = Normally Closed - Sequence 1 specification. ($12.00
charge per tag)

Example:
Sequence 1
Sequence 2

Part number for


tagging: 99981-00101
4 Complete Ordering Example: B315-029-029+LRB24-SR
6-Way Characterized Control Valve Product Range

Valve Nominal Size Type Suitable Actuators


Sequence 1 Sequence 2
Inches DN [mm] 6-way NPT Non Fail-Safe
Cv Cv

0.29 0.29 ½ 15 B315-029-029


0.29 0.46 ½ 15 B315-029-046
0.29 0.73 ½ 15 B315-029-073
0.29 1.16 ½ 15 B315-029-116
0.29 1.50 ½ 15 B315-029-150
0.46 0.29 ½ 15 B315-046-029
0.46 0.46 ½ 15 B315-046-046
0.46 0.73 ½ 15 B315-046-073 CCV
0.46 1.16 ½ 15 B315-046-116 Linear Characteristic
0.46 1.50 ½ 15 B315-046-150
0.73 0.29 ½ 15 B315-073-029
Mode of Operation
0.73 0.46 ½ 15 B315-073-046 The control valve is operated by an electronic actuator that
responds to a modulating VDC/4…20 mA control signal.
0.73 0.73 ½ 15 B315-073-073 The actuator will then move the ball of the valve to the

LRX24-MFT
LRB24-SR
0.73 1.16 ½ 15 B315-073-116 position dictated by the control signal thus changing the flow.

0.73 1.50 ½ 15 B315-073-150 Product Features


Linear characteristic, complete close-off resulting in 0%
1.16 0.29 ½ 15 B315-116-029 leakage.
1.16 0.46 ½ 15 B315-116-046 Actuator Specifications
1.16 0.73 ½ 15 B315-116-073 Control type 2-10 VDC
multi-function technology (MFT)
1.16 1.16 ½ 15 B315-116-116 Manual override LR...
1.16 1.50 ½ 15 B315-116-150 Electrical connection 3 ft. [1 m] cable with
½” conduit fitting
1.50 0.29 ½ 15 B315-150-029
1.50 0.46 ½ 15 B315-150-046 Valve Specifications
Service chilled or hot water, 60% glycol
1.50 0.73 ½ 15 B315-150-073
Flow characteristic linear
1.50 1.16 ½ 15 B315-150-116 Controllable flow range
Sequence 1 (0 to 30º angle)
1.50 1.50 ½ 15 B315-150-150 Dead zone 30º to 60º
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

1.75 2.0 ½ 15 B315-175-200 Sequence 2 (60º to 90º angle)


Sizes ½”
2.0 1.75 ½ 15 B315-200-175 End fitting NPT
2.0 2.0 ½ 15 B315-200-200 Materials
Body nickel plated brass
All prices are in US Dollars (USD)

Ball chrome plated brass


Stem nickel plated brass
Seats Teflon® PTFE
Seat O-rings EPDM
Characterizing disc chrome plated steel
Stem O-rings EPDM
Media temperature range 43°F to 180ºF [6ºC to 82ºC]
Body pressure rating 232 psi
Close-off pressure 50 psi
Maximum differential
pressure (∆P) 15 psi
Leakage 0%
Teflon® is a registered trademark of DuPont™

Sequence 1 Sequence 2

ly ly To C To C Supp Sup
Supp Supp oil oil
To C
oil
To C
oil ly

rn to rn to
Retu e Retu e Retu
rn Retu rn
Retu Coil rn
Retu Coil Retu
rn Ret
rn
Sourc Sourc Coil From Coil From From From Sourc To Sou
e

9-1
6-Way Characterized Control Valve Product Range

Valve Nominal Size Type Suitable Actuators


Sequence 1 Sequence 2
Inches DN [mm] 6-way NPT Non Fail-Safe
Cv Cv

0.73 0.73 ¾ 20 B320-073-073


0.73 1.16 ¾ 20 B320-073-116
0.73 1.86 ¾ 20 B320-073-186
0.73 2.9 ¾ 20 B320-073-290
1.16 0.73 ¾ 20 B320-116-073
1.16 1.16 ¾ 20 B320-116-116
1.16 1.86 ¾ 20 B320-116-186
1.16 2.9 ¾ 20 B320-116-290 CCV
1.86 0.73 ¾ 20 B320-186-073 Linear Characteristic
1.86 1.16 ¾ 20 B320-186-116
1.86 1.86 ¾ 20 B320-186-186

LRX24-MFT
Mode of Operation

LRB24-SR
1.86 2.9 ¾ 20 B320-186-290 The control valve is operated by an electronic actuator that
responds to a modulating VDC/4…20 mA control signal.
2.9 0.73 ¾ 20 B320-290-073 The actuator will then move the ball of the valve to the
2.9 1.16 ¾ 20 B320-290-116 position dictated by the control signal thus changing the flow.

2.9 1.86 ¾ 20 B320-290-186 Product Features


Linear characteristic, complete close-off resulting in 0%
2.9 2.9 ¾ 20 B320-290-290 leakage.
2.9 4.0 ¾ 20 B320-290-400 Actuator Specifications
2.9 4.7 ¾ 20 B320-290-470 Control type 2-10 VDC
multi-function technology (MFT)
4.0 2.9 ¾ 20 B320-400-290 Manual override LR..., NR...
4.0 4.0 ¾ 20 B320-400-400 Electrical connection 3 ft. [1 m] cable with
½” conduit fitting
4.0 4.7 ¾ 20 B320-400-470
4.9 2.9 ¾ 20 B320-490-290 Valve Specifications
Service chilled or hot water, 60% glycol
4.9 4.0 ¾ 20 B320-490-400
Flow characteristic linear
4.9 4.7 ¾ 20 B320-490-470 Controllable flow range
Sequence 1 (0 to 30º angle)
NRB24-SR

Dead zone 30º to 60º

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


NRX24-

Sequence 2 (60º to 90º angle)


MFT

7.4 7 1 25 B325-740-700
Sizes ¾”, 1”
End fitting NPT
Materials
Body nickel plated brass

All prices are in US Dollars (USD)


Ball chrome plated brass
Stem nickel plated brass
Seats Teflon® PTFE
Seat O-rings EPDM
Characterizing disc chrome plated steel
Stem O-rings EPDM
Media temperature range 43°F to 180ºF [6ºC to 82ºC]
Body pressure rating 232 psi
Close-off pressure 50 psi
Maximum differential
pressure (∆P) 15 psi
Leakage 0%
Teflon® is a registered trademark of DuPont™

Sequence 1 Sequence 2

ly ly To C To C Supp Supp
Supp Supp oil oil
To C
oil
To C
oil ly ly

rn to rn to
Retu e Retu e Retu
rn Retu rn
Retu Coil rn
Retu Coil Retu
rn Retu
rn
rn
Sourc Sourc Coil From Coil From From From Sourc To Sourc To
e e

9-2
6-Way Characterized Control Valves with Non Fail-Safe Actuators

6-WAY VALVES
Chrome Plated Brass Ball and Nickel Plated Brass Stem, NPT Female Ends

Valve Specifications
chilled or hot water, up to 60%
Service
glycol
Flow Characteristic linear
End Fitting NPT female ends
Body nickel plated brass
Ball chrome plated brass
Stem nickel plated brass
Seat Teflon® PTFE
O-ring EPDM
Characterized Disc chrome plated steel
Media Temperature Range 43°F to 180°F [6°C to 82°C]
Max Differential Pressure 15 psi for typical applications
Leakage 0%

ACTUATOR PART # LRB24-SR LRX24-MFT


Control 2-10 VDC Modulating/MFT
Manual Override • •
Running Time (Motor) 90 seconds 150 seconds (default), variable (35 to 150 seconds)
Electrical Connection 3 ft, 18 GA plenum cable with ½” conduit connector 3 ft, 18 GA plenum cable with ½” conduit connector
6-Way
Body
Close-Off
Seq 1 Seq 2 Size Pressure
Model # Pressure
Cv Cv [mm] Rating
[psi]
[psi]
B315-029-029 0.29 $775 $832
B315-029-046 0.46 $775 $832
B315-029-073 0.29 0.73 $775 $832
B315-029-116 1.16 $775 $832
B315-029-150 1.5 $775 $832
B315-046-029 0.29 $775 $832
B315-046-046 0.46 $775 $832
B315-046-073 0.46 0.73 $775 $832
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

B315-046-116 1.16 $775 $832


B315-046-150 1.5 $775 $832
B315-073-029 0.29 $775 $832
B315-073-046 0.46 $775 $832
B315-073-073 0.73 0.73 $775 $832
All prices are in US Dollars (USD)

B315-073-116 1.16 ½” $775 $832


232 50
B315-073-150 1.5 [15] $775 $832
B315-116-029 0.29 $775 $832
B315-116-046 0.46 $775 $832
B315-116-073 1.16 0.73 $775 $832
B315-116-116 1.16 $775 $832
B315-116-150 1.5 $775 $832
B315-150-029 0.29 $775 $832
B315-150-046 0.46 $775 $832
1.5
B315-150-073 0.73 $775 $832
B315-150-116 1.16 $775 $832
B315-150-150 1.5 $775 $832
B315-175-200 1.75 2.0 $775 $832
B315-200-175 2.0 1.75 $775 $832
B315-200-200 2.0 2.0 $775 $832

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

9-3
6-Way Characterized Control Valves with Non Fail-Safe Actuators
6-WAY VALVES

Chrome Plated Brass Ball and Nickel Plated Brass Stem, NPT Female Ends

Valve Specifications
chilled or hot water, up to 60%
Service
glycol
Flow Characteristic linear
End Fitting NPT female ends
Body nickel plated brass
Ball chrome plated brass
Stem nickel plated brass
Seat Teflon® PTFE
O-ring EPDM
Characterized Disc chrome plated steel
Media Temperature Range 43°F to 180°F [6°C to 82°C]
Max Differential Pressure 15 psi for typical applications
Leakage 0%

ACTUATOR PART # LRB24-SR LRX24-MFT NRB24-SR NRX24-MFT


Control 2-10 VDC Modulating/MFT 2-10 VDC Modulating/MFT
Manual Override • • • •

150 seconds (default), variable 150 seconds (default), variable


Running Time (Motor) 90 seconds 90 seconds
(35 to 150 seconds) (45 to 150 seconds)

3 ft, 18 GA plenum cable with 3 ft, 18 GA plenum cable with 3 ft, 18 GA plenum cable with 3 ft, 18 GA plenum cable with
Electrical Connection
½” conduit connector ½” conduit connector ½” conduit connector ½” conduit connector
6-Way
Body
Close-Off
Seq 1 Seq 2 Size Pressure
Model # Pressure
Cv Cv [mm] Rating
[psi]
[psi]
B320-073-073 0.73 $943 $1,010
B320-073-290 2.9 $943 $1,010
0.73
B320-073-186 1.86 $943 $1,010
B320-073-116 $943 $1,010
1.16
B320-116-116 $943 $1,010
B320-116-073 0.73 $943 $1,010

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


1.16
B320-116-290 2.9 $943 $1,010
B320-116-186 $943 $1,010
1.86
B320-186-186 $943 $1,010
B320-186-116 1.16 $943 $1,010
1.86
B320-186-073 0.73 $943 $1,010

All prices are in US Dollars (USD)


B320-186-290 ¾” $943 $1,010
2.9
B320-290-290 [20] $943 $1,010
232 50
B320-290-186 1.86 $943 $1,010
B320-290-116 1.16 $943 $1,010
2.9
B320-290-073 0.73 $943 $1,010
B320-290-400 4 $943 $1,010
B320-290-470 4.7 $943 $1,010
B320-400-290 2.9 $943 $1,010
B320-400-400 4.0 4 $943 $1,010
B320-400-470 4.7 $943 $1,010
B320-490-290 2.9 $943 $1,010
B320-490-400 4.9 4 $943 $1,010
B320-490-470 4.7 $943 $1,010
1”
B325-740-700 7.4 7 $1,109 $1,176
[25]

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

9-4
10
ZONE VALVES
Traditional Solution
• Designed to fit in compact areas where
on/off control is required.
• Synchronous motor winds the return
spring and moves the valve paddle to
the desired position.
• Enhanced motion gear action reduces
motor wear and provides quiet operation.

Nicole Eannarino, Group Leader, Customizing


Electronic Zone Valve Nomenclature

ZONE2 15 N -10 +ZONE24NC -S


Valve Valve Size End Fitting Cv Actuator Type
Zone2 = 2-way 15 = ½” N = NPT Female Connection -10 = 1.0 24NC = 24 Volt Normally Closed -S = Built-in
Zone3 = 3-way 20 = ¾” S = Sweat Connection -25 = 2.5 24NO = 24 Volt Normally Open Auxiliary
Switch
25 = 1” -35 = 3.5 120NC = 120 Volt Normally Closed
-50 = 5.0 120NO = 120 Volt Normally Open
-80 = 8.0

Ordering Example

1 Choose the valve.

ZONE215N-10+ ZONE24NC -S Tagging (if needed)


3
2 Choose the actuator. Does order
require
Set-Up tagging?

Tagging:
Valves may be
tagged per customer
24 = 24 VAC
-S = Built-in specification. ($12.00
Auxiliary charge per tag)
Switch
Example:
FCU-1

NC = Normally Closed Part number for tagging:


99981-00101

4 Complete Ordering Example: ZONE215N-10+ZONE24NC-S


Electronic Zone Valve Product Range

Valve Nominal Size Type Suitable Actuators


Cv Inches DN [mm] 2-way NPT 2-way Sweat Normally Closed Normally Open
1 ½ 15 ZONE215N-10 ZONE215S-10

Zone (with Switch)

Zone (with Switch)


2.5 ½ 15 ZONE215N-25 ZONE215S-25
3.5 ½ 15 ZONE215N-35 ZONE215S-35

Zone

Zone
3.5 ¾ 20 ZONE220N-35 ZONE220S-35
5 ¾ 20 ZONE220N-50 ZONE220S-50
8 1 25 ZONE225N-80 ZONE225S-80

Mode of Operation
Zone valves provide a convenient way to create individual
Valve Nominal Size Type Suitable Actuators zones or equipment isolation in a hydronic system.
Utilizing one pump along with multiple zone valves, flow
Cv Inches DN [mm] 3-way NPT 3-way Sweat Normally Closed can be started, stopped, or diverted through the system
to provide individual room or area comfort control and
1 ½ 15 ZONE315N-10 ZONE315S-10 energy savings.

Zone (with Switch)


2.5 ½ 15 ZONE315N-25 ZONE315S-25
Product Features
3.5 ½ 15 ZONE315N-35 ZONE315S-35 Zone valve is designed to fit in compact areas where on/off
Zone

control is required using 24 VAC or 120 VAC.


3.5 ¾ 20 ZONE320N-35 ZONE320S-35
5 ¾ 20 ZONE320N-50 ZONE320S-50 Actuator Specifications

8 1 25 ZONE325N-80 ZONE325S-80 Control type on/off


Manual override NC versions only
Electrical connection 6” [15 cm] wire lead 120V;
18” [45 cm] wire lead 24V

Valve Specifications
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

Service chilled or hot water,


50% glycol
Flow characteristic
Two-way on/off
Three-way on/off, diverting
All prices are in US Dollars (USD)

Sizes ½”, ¾” and 1”


End fitting NPT female or sweat
Materials

Body forged brass


Stem stainless steel
Stem seals EPDM
Paddle EPDM
Media temp range 32°F to 212°F [0°C to 100°C]
Body pressure rating 300 psi
Close-off pressure 20-75 psi
Leakage ANSI Class III 0.1%

10-1
Electronic Zone Valves
Installation

MOUNTING ORIENTATION
The valve can be installed vertically or horizontally, but not below horizontal.
ZONE VALVES

– A 3-way valve cannot be transformed into a 2-way valve and visa versa.
– The NC versions have an override handle.
– 3-way zone valves can be fitted with NC actuator only (rotate the valve body 180° for NO application).

FLOW PATTERN
2-way Valve 3-way Valve

2-WAY 3-WAY
Port ”A” closed
N.C. without power Port ”A” closed Port ”B” open
Port ”AB” open
Port ”A” open
N.C. open with power Port ”A” open Port ”B” closed
Port ”AB” open
B A
A Port ”A” open
N.C. manually open Port ”A” open Port ”B” open
(NO) (NC) Port ”AB” open
AB

Normally closed actuator Normally closed actuator

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


PIPING DIAGRAMS

Normally open actuator Normally closed actuator

All prices are in US Dollars (USD)

Installed on the return Installed on the return in diverting Installed on the return in diverting
configuration configuration

Installed on the supply Installed on the supply Installed on the supply

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

10-2
Electronic Zone Valves with Spring Return Actuators
2-way and 3-way Valves with NPT or Sweat Connection

Valve Specifications
chilled or hot water, up to 50%
Service
glycol
on/off (2-way)
Flow Characteristic
on/off, diverting (3-way)
NPT female
End Fitting
sweat

ZONE VALVES
Body forged brass
Stem stainless steel
Seat brass
Stem Seal EPDM
Paddle EPDM
Media Temperature Range
32°F to 212°F [0°C to 100°C]
(Water)
Leakage ANSI Class III 0.1%

ACTUATOR PART # ZONE24NC ZONE24NO ZONE24NC-S ZONE24NO-S


Control On/Off On/Off On/Off On/Off
Manual Override • •
Running Time (Motor) 20 to 40 seconds 20 to 40 seconds 20 to 40 seconds 20 to 40 seconds
Running Time (Fail-Safe) 5 seconds 5 seconds 5 seconds 5 seconds
Electrical Connection 18” wire leads 18” wire leads 18” wire leads 18” wire leads
2-Way with NPT Female Connection
Body
Close-Off
Size Pressure
Model # Cv Pressure
[mm] Rating
[psi]
[psi]
ZONE215N-10 1 75 $231 $231 $252 $252
ZONE215N-25 2.5 ½” [15] 50 $231 $231 $252 $252
ZONE215N-35 3.5 30 $231 $231 $252 $252
300
ZONE220N-35 3.5 30 $256 $256 $277 $277
¾” [20]
ZONE220N-50 5 25 $256 $256 $277 $277
ZONE225N-80 8 1” [25] 20 $329 $329 $349 $349
3-Way with NPT Female Connection
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

ZONE315N-10 1 75 $256 $277


ZONE315N-25 2.5 ½” [15] 50 $256 $277
ZONE315N-35 3.5 30 $256 $277
300
ZONE320N-35 3.5 30 $276 $295
¾” [20]
ZONE320N-50 5 25 $276 $295
All prices are in US Dollars (USD)

ZONE325N-80 8 1” [25] 20 $352 $372


2-Way with Sweat Connection
ZONE215S-10 1 75 $225 $225 $245 $245
ZONE215S-25 2.5 ½” [15] 50 $225 $225 $245 $245
ZONE215S-35 3.5 30 $225 $225 $245 $245
300
ZONE220S-35 3.5 30 $256 $256 $277 $277
¾” [20]
ZONE220S-50 5 25 $256 $256 $277 $277
ZONE225S-80 8 1” [25] 20 $319 $319 $339 $339
3-Way with Sweat Connection
ZONE315S-10 1 75 $246 $266
ZONE315S-25 2.5 ½” [15] 50 $246 $266
ZONE315S-35 3.5 30 $246 $266
300
ZONE320S-35 3.5 30 $268 $288
¾” [20]
ZONE320S-50 5 25 $268 $288
ZONE325S-80 8 1” [25] 20 $339 $359
Three-way valve can be installed in NC or NO configuration using the NC actuator.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

10-3
Electronic Zone Valves with Spring Return Actuators
2-way and 3-way Valves with NPT or Sweat Connection

Valve Specifications
chilled or hot water, up to 50%
Service
glycol
on/off (2-way)
Flow characteristic
on/off, diverting (3-way)
NPT female
End Fitting
sweat
ZONE VALVES

Body forged brass


Stem stainless steel
Seat brass
Stem Seal EPDM
Paddle EPDM
Media Temperature Range
32°F to 212°F [0°C to 100°C]
(Water)
Leakage ANSI Class III 0.1%

ACTUATOR PART # ZONE120NC ZONE120NO ZONE120NC-S ZONE120NO-S


Control On/Off On/Off On/Off On/Off
Manual Override • •
Running Time (Motor) 20 to 40 seconds 20 to 40 seconds 20 to 40 seconds 20 to 40 seconds
Running Time (Fail-Safe) 5 seconds 5 seconds 5 seconds 5 seconds
Electrical Connection 6” wire leads 6” wire leads 6” wire leads 6” wire leads
2-Way with NPT Female Connection
Body
Close-Off
Size Pressure
Model # Cv Pressure
[mm] Rating
[psi]
[psi]
ZONE215N-10 1 75 $231 $231 $252 $252
ZONE215N-25 2.5 ½” [15] 50 $231 $231 $252 $252
ZONE215N-35 3.5 30 $231 $231 $252 $252
300
ZONE220N-35 3.5 30 $256 $256 $277 $277
¾” [20]
ZONE220N-50 5 25 $256 $256 $277 $277
ZONE225N-80 8 1” [25] 20 $329 $329 $349 $349
3-Way with NPT Female Connection

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


ZONE315N-10 1 75 $256 $277
ZONE315N-25 2.5 ½” [15] 50 $256 $277
ZONE315N-35 3.5 30 $256 $277
300
ZONE320N-35 3.5 30 $276 $295
¾” [20]
ZONE320N-50 5 25 $276 $295

All prices are in US Dollars (USD)


ZONE325N-80 8 1” [25] 20 $352 $372
2-Way with Sweat Connection
ZONE215S-10 1 75 $225 $225 $245 $245
ZONE215S-25 2.5 ½” [15] 50 $225 $225 $245 $245
ZONE215S-35 3.5 30 $225 $225 $245 $245
300
ZONE220S-35 3.5 30 $256 $256 $277 $277
¾” [20]
ZONE220S-50 5 25 $244 $244 $264 $264
ZONE225S-80 8 1” [25] 20 $319 $319 $339 $339
3-Way with Sweat Connection
ZONE315S-10 1 75 $246 $266
ZONE315S-25 2.5 ½” [15] 50 $246 $266
ZONE315S-35 3.5 30 $246 $266
300
ZONE320S-35 3.5 30 $268 $288
¾” [20]
ZONE320S-50 5 25 $268 $288
ZONE325S-80 8 1” [25] 20 $339 $359

Three-way valve can be installed in NC or NO configuration using the NC actuator.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

10-4
CHARACTERIZED CONTROL
VALVES (CCV & HTCCV)
Control and Reliability
• Ball valve design offers self-cleaning
and zero leakage.
• Designed to meet the specifications where
higher media temperature is required.

CHARACTERIZED CONTROL VALVES


• High close-off rating ensures reliable shut CCV, HTCCV, BALL VALVES
off to prevent energy loss.

Pushpa Gohel, Assembler II, Line Leader


Sizing and Selection
Made Simple

Belimo SelectPro™
SelectPro is a quick and simple tool for accurately sizing and selecting valves, actuators,
and replacement solutions. The software walks you through step by step, providing the
CHARACTERIZED CONTROL VALVES

optimal product selection.


CCV, HTCCV, BALL VALVES

Discover the advantages


www.belimo.us
11
CHARACTERIZED CONTROL
VALVES (CCV)
Efficient Stable Control
• Characterized disc ensures an equal
percentage flow characteristic.
• Zero leakage eliminates energy loss.
• Maintenance free with self-cleaning ball
valve; no repacking required.

Scott Reed, Product Manager


Characterized Control Valve (CCV) Nomenclature

B2 09 +LRX 24 -MFT
Valve Valve Size Trim Material Actuator Type Power Supply Control
B2 = 2-way 07-80 = ½” to 3” B = Chrome Plated Non Fail-Safe 24 = 24 VAC/DC Blank = On/Off -S = Built-in
B3 = 3-way Brass Ball, TR 120 = 120 VAC* -3 = On/Off, Floating Point Auxiliary
Nickel Plated LRB, LRX 230 = 230 VAC -SR = 2-10 VDC Switch
Stem LRQX UP = 24 to 240 VAC -MFT = Multi-Function -T = Terminal
Blank = Stainless NRB, NRX Technology Strip
Steel Ball NRQX -MFT95 = 0-135 Ω N4 = NEMA
and Stem ARB, ARX 4/4X
-IP = Internet Protocol
ARQX
Fail-Safe
Spring Return
TFR, TFRX
LF
AFR, AFRX
Electronic
GKR

“X” models are customizable.


Refer to page 11-8 for programming
and cable options.

*LR and AR include 120-240 VAC

Ordering Example

3 For MFT Orders Only - Select Programming Code


1 Choose the valve actuator combination.

B209+LRX24-MFT NO Tagging (if needed)


4
2 Specify preference or configuration.
Does order
require
Set-Up tagging?

Non Fail-Safe Models


P-10001 (A01) Tagging:
NO = Normally Open Valves may be
P-100xx (Axx) Control voltage applications
NC = Normally Closed tagged per customer
P-200xx (Wxx) Pulse width modulation specification. ($12.00
Fail-Safe Models applications charge per tag)
NO/FO = Normally Open/Fail Open P-300xx (Fxx) Floating Point applications
NO/FC = Normally Open/Fail Closed P-400xx (Jxx) On/Off applications Example:
X-XXXXX Create custom MFT AHU-1
NC/FO = Normally Closed/Fail Open FCU-2
configuration code
NC/FC = Normally Closed/Fail Closed
X-XXXXX Create custom MFT
Part number for
See settings configuration in the field
tagging: 99981-00101
Refers to valve ports A to AB. with MFT-actuator PC-Tool software

5 Complete Ordering Example: B209+LRX24-MFT


Configuration:
+NO
Programming: +A01
Characterized Control Valve (CCV) Nomenclature

B6 250 S -070 +GRX 24 -MFT


Valve Valve Size Trim Material Cv Actuator Type Power Supply Control
B6 = 2-way 250-600 = 2½” S = Stainless 070 = 70 Cv Non Fail-Safe 24 = 24 VAC/DC Blank = On/Off N4 =
Flanged to 6” Steel Ball and 110 = 110 Cv ARB, ARX 120 = 120 VAC* -3 = On/Off, Floating NEMA 4/4X
Stem 186 = 186 Cv GRB, GRX 230 = 230 VAC Point
290 = 290 Cv Fail-Safe UP = 24 to 240 VAC -SR = 2-10 VDC
400 = 400 Cv Spring Return -MFT = Multi-Function
AFRB, AFRX Technology
Electronic -MFT95 = 0-135 Ω
GKRB, GKRX -IP = Internet Protocol

“X” models are customizable.


Refer to page 11-8 for programming
and cable options.

*AR includes 120-240 VAC

Ordering Example

3 For MFT Orders Only - Select Programming Code


1 Choose the valve actuator combination.

B6250S-070+GRX24-MFT NO Tagging (if needed)


4
2 Specify preference or configuration.
Does order
require
Set-Up tagging?

Non Fail-Safe Models


P-10001 (A01) Tagging:
NO = Normally Open Valves may be
P-100xx (Axx) Control voltage applications
NC = Normally Closed tagged per customer
P-200xx (Wxx) Pulse width modulation specification. ($12.00
Fail-Safe Models applications charge per tag)
NO/FO = Normally Open/Fail Open P-300xx (Fxx) Floating Point applications
NO/FC = Normally Open/Fail Closed P-400xx (Jxx) On/Off applications Example:
X-XXXXX Create custom MFT AHU-1
NC/FO = Normally Closed/Fail Open FCU-2
configuration code
NC/FC = Normally Closed/Fail Closed
X-XXXXX Create custom MFT
Part number for
See settings configuration in the field
tagging: 99981-00101
Refers to valve ports A to AB. with MFT-actuator PC-Tool software

5 Complete Ordering Example: B6250S-070+GRX24-MFT


Configuration:
+NO
Programming: +A01

11-1
Characterized Control Valve (CCV) Product Range

Valve Nominal Size Type Suitable Actuators

DN 2-way 3-way Non Fail- NEMA NEMA


Cv Inches Fail-Safe Internet Protocol
[mm] NPT NPT Safe 4X 4X

0.3 ½ 15 B207(B) B307(B)


0.46 ½ 15 B208(B) B308(B)
0.8 ½ 15 B209(B) B309(B)
1.2 ½ 15 B210(B) B310(B)
1.9 ½ 15 B211(B) B311(B) CCV
3 ½ 15 B212(B) B312(B) Equal Percentage

TFR Series
TR Series

Characteristic
4.7 ½ 15 B213(B) B313(B)
7.4 ½ 15 B214(B) Mode of Operation
The Characterized Control Valve is operated by a rotary
10 ½ 15 B215(B) B315(B)
actuator. The actuators are controlled by a standard voltage
16 ½ 15 B216(B)* B316(B)* for on/off control, a modulating signal, or floating point
control system which move the ball of the valve to the
NR Series
LR Series

LF Series

4.7 ¾ 20 B217(B) B317(B)

LR...-IP
position dictated by the control system.
7.4 ¾ 20 B218(B) B318(B) Product Features
The equal-percentage characteristic of the flow is ensured by
10 ¾ 20 B219(B) the integral characterizing disc. This characteristic provides
linear heating or cooling output from the coil improving
14 ¾ 20 B220(B)*
energy efficiency and comfort.
14 ¾ 20 B320(B)
Actuator Specifications
24 ¾ 20 B221(B)* B321(B)* Control type on/off, floating point, 2-10 VDC,
multi-function technology (MFT)
7.4 1 25 B222 B322 Manual override TR, LR, AR, NR, AFR series
10 1 25 B223 B323 Electrical connection 3 ft. [1 m] cable with ½”
conduit fitting or covered screw
19 1 25 B224 terminal strip
30 1 25 B225* B325* Valve Specifications
10 1¼ 32 B229 Service chilled or hot water, up to
60% glycol
19 1¼ 32 B230* Flow characteristic A-port equal percentage

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


B-port modified for constant
10 1¼ 32 B329 common port flow
19 1¼ 32 B330 Controllable flow range 75°

25 1¼ 32 B231 B331 Sizes ½”, ¾”, 1”, 1¼”, 1½”, 2”


End fitting NPT female

All prices are in US Dollars (USD)


37 1¼ 32 B232* Materials
Body forged brass, nickel plated
19 1½ 40 B238 B338
Ball stainless steel or chrome plated brass
29 1½ 40 B239 B339 Stem stainless steel or nickel plated brass
Seats Teflon® PTFE
37 1½ 40 B240* B340 Seat O-rings EPDM
Characterizing disc
46 1½ 40 B341 ½”- 1 ½” (2-way) Tefzel®
AFR Series
AFR Series
AR Series

AR Series

AKR...-IP

AFR...-IP
AR...-IP

29 2 50 B248 B347 ½”-1” (3-way) Tefzel®


2” (2-way) B248-B249 Tefzel®
37 2 50 B348 2” (2-way) B251-B253 stainless steel
1¼”- 2” (3-way) stainless steel
46 2 50 B249 B349 Stem O-rings EPDM
57 2 50 B250* B350 Media temp. range 0°F to 250°F [-18°C to +120°C]
Body pressure rating
65 2 50 B251 2-way
All ½”, ¾”, and 1” 600 psi
68 2 50 B351
1¼” up to B230 600 psi
83 2 50 B352 1¼” from B231 400 psi
1½” - 2” 400 psi
85 2 50 B252 3-way
All ½”, ¾”, and 1” 600 psi
120 2 50 B253 1¼”- 2” 400 psi
240 2 50 B254* Close-off pressure 200 psi
Maximum differential
* Models without characterizing discs. (B) Models with chrome plated brass ball and nickel NEW
pressure (∆P) 50 psi
plated brass stem
Leakage 0% for A to AB
< 2.0% for B to AB
Cv rating B port: 70% of A to AB Cv
Tefzel® and Teflon® are registered trademarks of DuPont™.
11-2
Characterized Control Valve (CCV) Product Range

Valve Nominal Size Type Suitable Actuators

Non
2-way NEMA Fail- NEMA
Cv Inches DN [mm] Fail- Internet Protocol
NPT 4X Safe 4X
Safe

60 2½ 65 B261
75 2½ 65 B262
110 2½ 65 B263

AFR Series

AFR Series
AR Series

AR Series

AKR...-IP

AFR...-IP
CCV

AR...-IP
150 2½ 65 B264
210 2½ 65 B265*
Equal Percentage
70 3 80 B277 Characteristic
130 3 80 B278
Mode of Operation
170 3 80 B280* The Characterized Control Valve is operated by a rotary
* Models without characterizing disc NEW actuator. The actuators are controlled by a standard voltage
for on/off control, a modulating signal, or floating point
control system which move the ball of the valve to the
position dictated by the control system.
Product Features
The equal-percentage characteristic of the flow is ensured by
the integral characterizing disc. This characteristic provides
linear heating or cooling output from the coil improving
energy efficiency and comfort.

Actuator Specifications
Control type on/off, floating point, 2-10 VDC,
multi-function technology (MFT)
Manual override AR and AFR series
Electrical connection 3 ft. [1 m] cable with ½”
conduit fitting or covered screw
terminal strip

Valve Specifications
Service chilled or hot water, up to
60% glycol
Flow characteristic A-port equal percentage
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

Controllable flow range 75°


Sizes 2½”, 3”
End fitting NPT female
Materials
Body forged brass, nickel plated
All prices are in US Dollars (USD)

Ball stainless steel


Stem stainless steel
Seats Teflon® PTFE
Seat o-rings EPDM
Characterizing disc Tefzel®
Stem o-rings EPDM
Media temp. range 0°F to 212°F [-18°C to +100°C]
Body pressure rating 400 psi
Close-off pressure 100 psi
Maximum differential
pressure (∆P) 30 psi
Leakage 0% for A to AB
Tefzel® and Teflon® are registered trademarks of DuPont™.

11-3
Characterized Control Valve (CCV) Product Range

Valve Nominal
2-way Flanged Suitable Actuators
Size
DN Non
NEMA Fail- NEMA
Cv Inches [mm] ANSI 125 ANSI 250 Fail- Internet Protocol
4X Safe 4X
Safe

70 2½ 65 B6250S-070 B6250S-070-250

AFR...-IP

AKR..-IP
AR...-IP
AFR

AFR
110 2½ 65 B6250S-110 B6250S-110-250

AR

AR
110 3 80 B6300S-110 B6300S-110-250
186 4 100 B6400S-186 B6400S-186-250
CCV

GR / GKR
Equal Percentage

GKR
GR
290 5 125 B6500S-290 B6500S-290-250 Characteristic
400 6 150 B6600S-400 B6600S-400-250
NEW NEW Mode of Operation
The Characterized Control Valve is operated by a rotary
actuator. The actuators are controlled by a standard voltage for
on/off control, a modulating signal, or floating point control
system which move the ball of the valve to the position dictated
by the control system.
Product Features
The equal-percentage characteristic of the flow is ensured by
the integral characterizing disc. This characteristic provides
linear heating or cooling output from the coil improving energy
efficiency and comfort.

Actuator Specifications
Control type on/off, floating point, 2-10 VDC,
multi-function technology (MFT)
Manual override AR, GR, AFR and GKR series
Electrical connection 3 ft. [1 m] cable with ½”
conduit fitting or covered screw
terminal strip

Valve Specifications
Service chilled or hot water, up to
60% glycol max.
Flow characteristic A-port equal percentage

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


Controllable flow range 75°
Sizes 2½”, 3”, 4”, 5”, 6”
End fitting ANSI Class 125 flange, flat face*,
ANSI 250
Materials

All prices are in US Dollars (USD)


Body cast iron GG25
Ball stainless steel
Stem stainless steel
Seats Teflon® PTFE
Seat o-rings EPDM rubber
Characterizing disc stainless steel
Stem o-rings EPDM
Media temp. range 0°F to 250°F [-18°C to +120°C]
Body pressure rating ANSI 125, Class B, ANSI 250
Close-off pressure 100 psi
Maximum differential
pressure (∆P) 50 psi
Leakage 0% for A to AB

*125 psi flanges have a plain flat face and should not be bolted
to a raised face flange.
Tefzel® and Teflon® are registered trademarks of DuPont™.

11-4
Characterized Control Valves

PIPING REDUCTION CHART


Piping Reduction Factor (Fp) - Correction Factor for Valves
Values in chart are corrected Cv ratings for indicated pipe size.

VALVE SIZE LINE SIZE


DN Cv
Model # Inches ½” ¾” 1” 1¼” 1½” 2” 2½” 3” 4” 5” 6” 8” 10”
[mm] Rating
B216* ½ 15 16 16 9 7.2 6.6 - - - - - - - - -
B221* ¾ 20 24 - 24 19 16 14.5 - - - - - - - -
B225* 1 25 30 - - 30 27.4 24.8 22 - - - - - - -
B230* 1¼ 32 19 - - - 19 18.8 18.2 17.8 - - - - - -
B232* 1¼ 32 37 - - - 37 35.5 31.8 29.9 - - - - - -
B240* 1½ 40 37 - - - - 37 35.5 34 33 - - - - -
B250* 2 50 57 - - - - - 57 55.8 54.2 52.2 - - - -
CCV (Threaded)

B251 2 50 65 - - - - - 65 63.2 60.9 58.1 - - - -


B252 2 50 85 - - - - - 85 81.1 76.5 71.1 - - - -
B253 2 50 120 - - - - - 120 109.7 99 88.1 - - - -

CCV
B254* 2 50 240 - - - - - 240 179.6 141.6 114.2 - - - -
B261 2½ 65 60 - - - - - - 60 59.6 58.3 57.5 - - -
B262 2½ 65 75 - - - - - - 75 74.2 71.8 70.4 - - -
B263 2½ 65 110 - - - - - - 110 107.4 100.7 96.7 - - -
B264 2½ 65 150 - - - - - - 150 143.6 128.6 120.6 - - -
B265* 2½ 65 210 - - - - - - 210 193.5 160.8 145.9 - - -
B277 3 80 70 - - - - - - - 70 69.3 68.6 68.1 - -
B278 3 80 130 - - - - - - - 130 125.8 121.5 118.8 - -
B280* 3 80 170 - - - - - - - 170 161 152.3 147 - -
B6250S-070 2½ 65 70 - - - - - - 70 69.3 67.4 66.2 - - -
LGCCV (Flanged) LGCCV (Flanged)

B6250S-110 2½ 65 110 - - - - - - 110 107.4 100.7 96.7 - - -


ANSI 125

B6300S-110 3 80 110 - - - - - - - 110 107.4 104.7 103 - -


B6400S-186 4 100 186 - - - - - - - - 186 183.3 179.8 175.1 -
B6500S-290 5 125 290 - - - - - - - - - 290 287 278.5 273.1
B6600S-400 6 150 400 - - - - - - - - - - 400 392.3 384
B6250S-070-250 2½ 65 70 - - - - - - 70 69.3 67.4 66.2 - - -
B6250S-110-250 2½ 65 110 - - - - - - 110 107.4 100.7 96.7 - - -
ANSI 250

B6300S-110-250 3 80 110 - - - - - - - 110 107.4 104.7 103 - -


B6400S-186-250 4 100 186 - - - - - - - - 186 183.3 179.8 175.1 -
B6500S-290-250 5 125 290 - - - - - - - - - 290 287 278.5 273.1
B6600S-400-250 6 150 400 - - - - - - - - - - 400 392.3 384
* Models without characterizing discs.
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

NOTE: Please use the corrected Cv values for the valves listed in the chart when installing them in pipes larger than the line size of the valve.
All CCVs not listed do not require piping reduction factors.

NOTE: The values shown in bold are based on test data. All other values are calculated.
All prices are in US Dollars (USD)

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

11-5
Characterized Control Valves
Set-Up

SET-UP - Specify Upon Ordering

2-WAY VALVE 3-WAY VALVE

TR24-3(-T) Power to pin 2 will drive Power to pin 2 will drive


valve CCW. Power to pin 3 valve CCW. Power to pin 3
will drive valve CW. will drive valve CW.
Stays in Last Position

LRB24-3(-T), ARB24-3(-T) Power to pin 2 will drive Power to pin 2 will drive
NON FAIL-SAFE

valve CW. Power to pin 3 valve CW. Power to pin 3


will drive valve CCW. The will drive valve CCW. The
above will fuction when above will fuction when
the directional switch is in the directional switch is in
the ”1” position to reverse, the ”1” position to reverse,
select the ”0” position. select the ”0” position.
CCV

TR24-SR(-T), LRB24-SR, NC: Normally closed A NO: Normally open A to AB, NC: Normally closed A NO: Normally open A to AB,
LRB(X)24-MFT, to AB, valve will open as valve will close as voltage to AB, valve will open as valve will close as voltage
ARB24-SR, ARB(X)24-MFT voltage increases increases voltage increases increases

TFRB24, LF24 US, NO/FO: Normally open A to NC/FC: Normally closed A NO/FO: Normally open A to NC/FC: Normally closed A
AFRB24 AB, valve will drive closed. to AB, valve will drive open. AB, valve will drive closed. to AB, valve will drive open.
Spring Action: Actuator Spring Action: Actuator will Spring Action: Actuator Spring Action: Actuator will
SPRING RETURN
Note Fail Position

will fail open A to AB upon fail closed A to AB upon will fail open A to AB upon fail closed A to AB upon
power loss. power loss. power loss. power loss.

TFRB24-3, TFRB24-SR, NC/FO: Normally closed A NC/FC: Normally closed A NO/FC: Normally open A NO/FO: Normally open A
TFRX24-MFT, to AB, valve will open as to AB, valve will open as to AB, valve will close as to AB, valve will close as
LF24-3 US, LF24-SR US, voltage increases. Actuator voltage increases. Actuator voltage increases. Actuator voltage increases. Actuator
LF24-MFT US, switch on CW. switch on CW. switch on CCW. switch on CCW.
AFRB24-SR, AFRX24-MFT Spring Action: Will fail open Spring Action: Will fail Spring Action: Will fail Spring Action: Will fail open
upon power loss. closed upon power loss. closed upon power loss. upon power loss.

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


GKRB24-3† Power to pin 4 will drive Power to pin 4 will drive
valve CW. Power to pin 3 valve CW. Power to pin 3
ELECTRONIC FAIL-SAFE

will drive valve CCW. The will drive valve CCW. The
above will fuction when the above will fuction when the

All prices are in US Dollars (USD)


directional switch is in the directional switch is in the
”FO” position to reverse, ”FO” position to reverse,
select the ”FC” position. select the ”FC” position.

GKRX24-MFT† NC: Normally closed A to NO: Normally open A to NC: Normally closed A to NO: Normally open A to
AB, will open as voltage AB, will close as voltage AB, will open as voltage AB, will close as voltage
increases when directional increases when directional increases when directional increases when directional
switch is in the ”FO” switch is in the ”FC” switch is in the ”FO” switch is in the ”FC”
position. position. position. position.

† The GK series Electronic Fail-Safe actuator will drive to a predetermined postion using the FO/FC dial on the actuator upon loss of power.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

11-6
Characterized Control Valves
Flow Pattern and Installation

FLOW PATTERNS
2-way Characterized Control Valves™ (Belimo B2 Series)

Flow direction

Two-way valves
should be installed
with the disc
upstream.
A  AB 100% A AB 0%

3-way Characterized Control Valves™ (Belimo B3 Series)


MIXING DIVERTING

The A-port must

CCV
be piped to the coil
to maintain proper
control.

A  AB 100% A  AB 0% AB A 100% AB A 0%


B  AB 0% B  AB 70% AB B 0% AB B 70%

INCORRECT PIPING

The A-port must be piped to the coil to maintain proper control.


WARNING! Do Not Pipe in this manner!
Note Valve Porting!
The A-port must be piped to the coil, not the B-port!
Flow is not possible from A to B. If AB-port is not piped as
the common port, the valve must be re-piped. It is good
practice to install a balancing valve in the bypass line. These
valves are intended for closed loop systems. Do not install
in an open loop system or in an application that is open to
atmospheric pressure.
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

OPERATION/INSTALLATION – CORRECT PIPING

2-way valves should be installed with the characterizing discs upstream. No damage to the valve will result if installed incorrectly with the characterizing discs
downstream.
3-WAY VALVES MUST BE PIPED CORRECTLY. They can be mixing or diverting. Mixing is the preferred piping arrangement.
All prices are in US Dollars (USD)

Not for use in change over applications.


Please consider industrial valves in section 13.

The Belimo Characterized Control Valve is a CONTROL valve, not a manual valve adapted for actuation. The control port is the A-port. It is similar to the globe valve in that the
middle port is the B or bypass port. The common port AB is on the main opposite the A-port. These diagrams are for typical applications only. Consult engineering
specification and drawings for particular circumstances.
REDUCED B-PORT FLOW
Note: The B-port flow of the 3-way CCV is lower than that of the A-port. In most applications this is beneficial since the reduced flow compensates for the inexistent
pressure drop across the coil in the bypass mode. Therefore, proper sizing is important to avoid flow noise in particular when the system is designed with constant
speed pumps. Please refer to our valve sizing and selection guidelines.
The flow velocity in the pipe upstream and downstream of the valve should be considered as well. The typical HVAC design maximum flow is 4 to 8 ft./s to avoid
noise issues.
Also, the pipe reduction factor must be considered. Pipe reducers decrease the Cv value of a valve and consequently increase the pressure drop across the valve
creating a situation that could lead to noise or a lower than designed flow.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

11-7
Customize Products
Default and MFT Programming Codes

ARB... 1 ACTUATOR TYPE


B = Basic stocked product 2 CABLES
• Standard 150 second run time.
• Standard 3’ plenum cable with CABLE
SIZE CABLE CODE List Price
(with conduit fi tting)
conduit connector.
Typical Lead Time: 1 day 24V Plenum Rated 3 ft. C1 No Charge
10 ft. C3 $31

ARX... 16 ft. C5 $52

X = Customizable product 120V Appliance Rated 3 ft. A1 No Charge


• Choice of 10’ or 16’ cable with 10 ft. A3 $31
conduit connector.
• Option of 3’ right angle cables for 16 ft. A5 $52
tight spaces (-3 version only). 3 PROGRAM
• Factory programming for run time, CONTROL
control signal and feedback. CONFIGURATION
Typical Lead Time: 3 days or less ACTUATOR TYPE P-CODE CONTROL INPUT FEEDBACK POSITION RUNNING TIME List Price‡
DESCRIPTION
CCV

-3 and SR 2-10 VDC


N/A 0 2-10 VDC (for -3) 150 seconds No Charge
(for -3)
Reorder number consists of options which
2-10 VDC
differ from standard product. This number is N/A 2 2-10 VDC (for -SR) 90 seconds No Charge
(for -SR)
printed on the actuator for easy reordering. P-10001 A01 2-10 VDC 2-10 VDC 150 seconds No Charge*
For example: MFT and PC
P-10002 A02 0.5-10 VDC 0.5-10 VDC 150 seconds No Charge
Reorder # for a ARX24-MFT P-10003 A03 2-10 VDC 0.5-5 VDC 150 seconds No Charge
P-10004 A04 4-7 VDC 2-10 VDC 150 seconds $37
is: AR1000C3A01 P-10005 A05 6-9 VDC 2-10 VDC 150 seconds $37
P-10006 A06 10.5 -13.5 VDC 2-10 VDC 150 seconds $37
P-10007 A07 0.5-5 VDC 2-10 VDC 150 seconds $37
P-10009 A09 5-10 VDC 2-10 VDC 150 seconds $37
3 No Charge
P-10010 A10 5-10 VDC 0-10 VDC 150 seconds $37
2 $31 P-10013 A13 0.5-10 VDC 2-10 VDC 150 seconds $37
P-10015 A15 2-5 VDC 2-10 VDC 150 seconds $37
1 $614 P-10016 A16 2-6 VDC 2-10 VDC 150 seconds $37
$645 Final Price P-10017 A17 6-10 VDC 2-10 VDC 150 seconds $37
P-10018 A18 14-17 VDC 2-10 VDC 150 seconds $37
P-10020 A20 9-12 VDC 2-10 VDC 150 seconds $37
P-10028 A28 0.5-10 VDC 0.5-10 VDC 100 seconds No Charge
P-10031 A31 0.5-4 VDC 2-10 VDC 150 seconds $37
P-10063 A63 0.5-4.5 VDC 0.5- 4.5 VDC 150 seconds No Charge

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


P-10032 A32 6-14 VDC 2-10 VDC 150 seconds $37
P-10064 A64 5.5-10 VDC 5.5-10 VDC 150 seconds No Charge
N/A AAT 2-10 VDC 2-10 VDC 20 seconds No Charge
0.59-2.93
P-20001 W01 2-10 VDC 150 seconds $37
seconds

All prices are in US Dollars (USD)


0.02 to 5.00
P-20002 W02 2-10 VDC 150 seconds No Charge
seconds
0.10 to 25.50
P-20003 W03 2-10 VDC 150 seconds No Charge
seconds
0.10 to 25.60
P-20004 W04 2-10 VDC 150 seconds $37
seconds
0.10 to 5.20
P-20005 W05 0.5-5.0 VDC 150 seconds $37
seconds
P-30001 F01 Floating Point 2-10 VDC 150 seconds No Charge
P-30002 F02 Floating Point 0.5-10 VDC 150 seconds $37
P-40002 J02 On/Off 2-10 VDC 150 seconds No Charge
S01
N/A Phasecut 2-10 VDC 150 seconds No Charge
(-PC only)
R01
P-16001 0 to 135 Ω 2-10 VDC 150 seconds No Charge
(-MFT95 only)
NOTE: Additional P-codes are available, consult factory.
‡ Add to list price of assembly.
*P-10001 is the default configuration for MFT.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

11-8
B2/B3 Series Characterized Control Valves with Non Fail-Safe Actuators
2-way and 3-way Valves with Chrome Plated Brass Ball and Brass Stem, NPT Female Ends

Valve Specifications
chilled , hot water, up to 60%
Service
glycol
Flow Characteristic (B2) A-port equal percentage
A- port equal percentage; B-port Visit www.belimo.us to see additional non fail-safe
Flow Characteristic (B3)
modified linear for constant flow actuator options including 120V and -S models.
Controllable Flow Range 75°
End Fitting NPT female
Body forged brass, nickel plated
Ball chrome plated brass
Stem nickel plated brass
Seat Teflon® PTFE
Characterized Disc TEFZEL®
Seat 0-ring EPDM
Media Temperature Range
0°F to 250°F [-18°C to +120°C]
(Water)
Max Differential Pressure
50 psi
(Water)
Leakage 0% for A to AB, <2.0% for B to AB

CCV
A-port: as stated in chart
Cv Flow Rating
B-port: 70% of A to AB Cv

ACTUATOR PART # TR24-3-T US TR24-3 US TR24-SR-T US TR24-SR US LRB24-3 LRB24-SR


Control On/Off, Floating Point On/Off, Floating Point Modulating Modulating On/Off, Floating Point Modulating
Manual Override • • • • • •
Running Time (Motor) 90 seconds 90 seconds 90 seconds 90 seconds 90 seconds 90 seconds
3 ft, 18 GA plenum 3 ft, 18 GA plenum
screw terminal (for 3 ft, 18 GA screw terminal (for 3 ft, 18 GA
Electrical Connection cable with ½” conduit cable with ½” conduit
26 to 14 GA wire) plenum cable 26 to 14 GA wire) plenum cable
connector connector
2-Way
Close-Off
Size Body Pressure
Model # Cv Pressure
[mm] Rating [psi]
[psi]
B207B 0.3 200 $210 $223 $309 $326 $288 $428
B208B 0.46 200 $210 $223 $309 $326 $288 $428
B209B 0.8 200 $210 $223 $309 $326 $288 $428
B210B 1.2 200 $213 $226 $312 $329 $291 $430
B211B 1.9 ½” 200 $213 $226 $312 $329 $291 $430
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

B212B 3 [15] 200 $217 $230 $316 $334 $297 $438


B213B 4.7 200 $219 $232 $318 $336 $299 $440
B214B 7.4 600 200 $223 $236 $324 $340 $304 $445
B215B 10 200 $223 $236 $324 $340 $306 $447
B216B* 16 200 $225 $239 $327 $342 $309 $450
All prices are in US Dollars (USD)

B217B 4.7 200 $268 $283 $370 $385 $345 $486


B218B 7.4 200 $271 $287 $373 $388 $348 $489
¾”
B219B 10 200 $271 $287 $373 $388 $350 $491
[20]
B220B* 14 200 $276 $293 $379 $393 $352 $493
B221B* 24 200 $356 $498
3-Way Mixing/Diverting
B307B 0.3 200 $256 $271 $382 $397 $335 $477
B308B 0.46 200 $256 $271 $382 $397 $335 $477
B309B 0.8 200 $256 $271 $382 $397 $335 $477
B310B 1.2 200 $258 $273 $384 $400 $337 $479
½”
B311B 1.9 200 $258 $273 $384 $400 $337 $479
[15]
B312B 3 200 $266 $283 $392 $408 $341 $483
B313B 4.7 600 200 $268 $286 $394 $410 $345 $487
B315B 10 200 $269 $287 $396 $412 $352 $494
B316B* 16 200 $278 $297 $406 $422 $354 $496
B317B 4.7 200 $332 $348 $458 $474 $378 $520
B318B 7.4 ¾” 200 $331 $347 $457 $473 $382 $524
B320B 14 [20] 200 $389 $531
B321B* 24 200 $392 $534

*Models without characterizing discs.


For corrected Cvs with piping reduction factor refer to page 11-5.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

11-9
B2/B3 Series Characterized Control Valves with Fail-Safe Actuators
2-way and 3-way Valves with Chrome Plated Brass Ball and Brass Stem, NPT Female Ends

Valve Specifications
chilled , hot water, up to 60%
Service
glycol
Flow Characteristic (B2) A-port equal percentage
Flow Characteristic (B3)
A- port equal percentage; B-port Visit www.belimo.us to see additional fail-safe
modified linear for constant flow
actuator options including 120V and -S models.
Controllable Flow Range 75°
End Fitting NPT female
Body forged brass, nickel plated
Ball chrome plated brass
Stem nickel plated brass
Seat Teflon® PTFE
Characterized Disc TEFZEL®
Seat 0-ring EPDM
Media Temperature Range
0°F to 250°F [-18°C to +120°C]
(Water)
Max Differential Pressure
50 psi
(Water)
Leakage 0% for A to AB, <2.0% for B to AB
A-port: as stated in chart
CCV

Cv Flow Rating
B-port: 70% of A to AB Cv

ACTUATOR PART # TFRB24 TFRB24-3 TFRB24-SR LF24 US LF24-3 US LF24-SR US


Control On/Off Floating Point Modulating On/Off Floating Point Modulating
Running Time (Motor) <75 seconds 90 seconds 90 seconds 75 seconds 150 seconds 150 seconds
Running Time (Fail-Safe) 75 seconds <25 seconds <25 seconds <25 seconds <25 seconds <25 seconds
3 ft, 18 GA appliance 3 ft, 18 GA plenum 3 ft, 18 GA plenum 3 ft, 18 GA appliance 3 ft, 18 GA plenum 3 ft, 18 GA plenum
Electrical Connection cable with ½” conduit cable with ½” conduit cable with ½” conduit cable with ½” conduit cable with ½” conduit cable with ½” conduit
connector connector connector connector connector connector
2-Way
Close-Off
Size Body Pressure
Model # Cv Pressure
[mm] Rating [psi]
[psi]
B207B 0.3 200 $406 $463 $498 $462 $588 $605
B208B 0.46 200 $406 $463 $498 $462 $588 $605
B209B 0.8 200 $406 $463 $498 $462 $588 $605
B210B 1.2 200 $409 $467 $501 $464 $591 $607
B211B 1.9 ½” 200 $409 $467 $501 $464 $591 $607

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


B212B 3 [15] 200 $414 $472 $505 $472 $597 $613
B213B 4.7 200 $416 $474 $507 $474 $600 $615
B214B 7.4 600 200 $418 $477 $511 $477 $602 $617
B215B 10 200 $418 $477 $511 $483 $608 $624
B216B* 16 200 $418 $477 $511 $485 $610 $626

All prices are in US Dollars (USD)


B217B 4.7 200 $467 $525 $560 $528 $653 $670
B218B 7.4 200 $469 $527 $562 $530 $655 $673
¾”
B219B 10 200 $469 $527 $562 $533 $658 $676
[20]
B220B* 14 200 $474 $531 $566 $535 $661 $678
B221B* 24 200 $538 $664 $681
3-Way Mixing/Diverting
B307B 0.3 200 $480 $560 $585 $549 $675 $698
B308B 0.46 200 $480 $560 $585 $549 $675 $698
B309B 0.8 200 $480 $560 $585 $549 $675 $698
B310B 1.2 200 $482 $562 $587 $551 $677 $700
½”
B311B 1.9 200 $485 $565 $591 $551 $677 $700
[15]
B312B 3 200 $489 $569 $595 $563 $688 $711
B313B 4.7 600 200 $494 $574 $601 $565 $690 $713
B315B 10 200 $494 $574 $601 $567 $692 $716
B316B* 16 200 $494 $574 $601 $569 $694 $718
B317B 4.7 200 $535 $615 $641 $608 $733 $756
B318B 7.4 ¾” 200 $533 $613 $639 $610 $736 $759
B320B 14 [20] 200 $614 $740 $763
B321B* 24 200 $617 $744 $766

*Models without characterizing discs.


For corrected Cvs with piping reduction factor refer to page 11-5.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

11-10
B2 Series Characterized Control Valves with Non Fail-Safe Actuators
2-way Valve with Stainless Steel Ball and Stem, NPT Female Ends

Valve Specifications
chilled , hot water, up to 60%
Service
glycol
Flow Characteristic equal percentage
Controllable Flow Range 75° Visit www.belimo.us for additional non fail-safe
End Fitting NPT female actuator options including 120V and -S models.
Body forged brass, nickel plated
Ball stainless steel
Stem stainless steel
Seat Teflon® PTFE
Characterized Disc TEFZEL®
Seat 0-ring EPDM
Media Temperature Range
0°F to 250°F [-18°C to +120°C]
(Water)
Max Differential Pressure
50 psi
(Water)
Leakage 0%

CCV
ACTUATOR PART # TR24-3-T US TR24-3 US TR24-SR-T US TR24-SR US LRB24-3 LRB24-SR LRX24-MFT
On/Off, On/Off, On/Off,
Control Modulating Modulating Modulating Modulating/MFT
Floating Point Floating Point Floating Point
Manual Override • • • • • • •

150 seconds
Running Time (Motor) 90 seconds 90 seconds 90 seconds 90 seconds 90 seconds 90 seconds
(variable)
3 ft, 18 GA 3 ft, 18 GA 3 ft, 18 GA
screw terminal screw terminal
3 ft, 18 GA 3 ft, 18 GA plenum cable plenum cable plenum cable
Electrical Connection (for 26 to 14 GA (for 26 to 14 GA
plenum cable plenum cable with ½” conduit with ½” conduit with ½” conduit
wire) wire)
connector connector connector
2-Way
Close-Off
Size Body Pressure
Model # Cv Pressure
[mm] Rating [psi]
[psi]
B207 0.3 200 $242 $262 $369 $384 $309 $431 $569
B208 0.46 200 $242 $262 $369 $384 $309 $431 $569
B209 0.8 200 $242 $262 $369 $384 $309 $431 $569
B210 1.2 200 $252 $269 $376 $391 $312 $435 $572
B211 1.9 ½” 200 $252 $269 $376 $391 $312 $435 $572
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

B212 3 [15] 200 $256 $273 $381 $396 $314 $438 $574
B213 4.7 200 $260 $277 $385 $401 $330 $451 $589
B214 7.4 200 $266 $286 $391 $407 $337 $458 $596
B215 10 200 $266 $286 $391 $407 $348 $459 $608
B216* 16 200 $318 $330 $436 $451 $350 $459 $610
All prices are in US Dollars (USD)

B217 4.7 600 200 $310 $330 $415 $430 $364 $465 $623
B218 7.4 200 $312 $332 $416 $431 $366 $470 $625
¾”
B219 10 200 $312 $332 $418 $432 $370 $477 $630
[20]
B220* 14 200 $316 $337 $419 $434 $372 $478 $632
B221* 24 200 $375 $479 $635
B222 7.4 200 $384 $496 $644
B223 10 1” 200 $391 $500 $651
B224 19 [25] 200 $391 $503 $651
B225* 30 200 $394 $508 $654
B229 10 1¼” 200 $436 $537 $695
B230* 19 [32] 200 $439 $544 $698

*Models without characterizing discs.


For corrected Cvs with piping reduction factor refer to page 11-5.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

11-11
B2 Series Characterized Control Valves with Non Fail-Safe Actuators
2-way Valve with Stainless Steel Ball and Stem, NPT Female Ends

Valve Specifications
chilled , hot water, up to 60%
Service
glycol
Flow Characteristic equal percentage
Controllable Flow Range 75° Visit www.belimo.us for additional non fail-safe
End Fitting NPT female actuator options including 120V and -S models.
Body forged brass, nickel plated
Ball stainless steel
Stem stainless steel
Seat Teflon® PTFE
Characterized Disc TEFZEL® or stainless steel
Seat 0-ring EPDM
Media Temp. Range
0°F to 250°F [-18°C to +120°C]
1.25” - 2”
Media Temp. Range
0°F to 212°F [-18°C to 100°C]
2.5” - 3”
Max Differential Pressure
50 psi
1.25” - 2”
Max Differential Pressure
30 psi
2.5” - 3”
CCV

Leakage 0%

ACTUATOR PART # ARB24-3 ARB24-SR ARX24-MFT


Control On/Off, Floating Point Modulating Modulating/MFT
Manual Override • • •

Running Time (Motor) 90 seconds 90 seconds 150 seconds (variable)


3 ft, 18 GA plenum cable with 3 ft, 18 GA plenum cable with 3 ft, 18 GA plenum cable with
Electrical Connection
½” conduit connector ½” conduit connector ½” conduit connector
2-Way
Close-Off
Size Body Pressure
Model # Cv Pressure
[mm] Rating [psi]
[psi]
B231 25 1¼” 200 $506 $673 $733
B232* 37 [32] 200 $518 $682 $744
B238 19 200 $518 $682 $744
1½”
B239 29 200 $518 $682 $744
[40]
B240* 37 200 $520 $684 $746
B248 29 200 $670 $835 $897
B249 46 200 $674 $838 $900
B250* 57 200 $676 $840 $902

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


2”
B251 65 200 $976 $1,218
[50]
B252 85 200 $1,049 $1,326
400
B253 120 200 $1,135 $1,379
B254* 240 200 $1,147 $1,622
B261 60 100 $1,153 $1,322

All prices are in US Dollars (USD)


B262 75 100 $1,156 $1,400
2½”
B263 110 100 $1,234 $1,477
[65]
B264 150 100 $1,316 $1,559
B265* 210 100 $1,478 $1,574
B277 70 100 $1,331 $1,575
3”
B278 130 100 $1,409 $1,652
[80]
B280* 170 100 $1,737 $1,982

*Models without characterizing discs.


For corrected Cvs with piping reduction factor refer to page 11-5.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

11-12
B3 Series Characterized Control Valves with Non Fail-Safe Actuators
3-way Valve with Stainless Steel Ball and Stem, NPT Female Ends

Valve Specifications
chilled , hot water, up to 60%
Service
glycol
A-port equal percentage, B-port
Flow Characteristic
modified linear for constant flow Visit www.belimo.us for additional non fail-safe
Controllable Flow Range 75° actuator options including 120V and -S models.
End Fitting NPT female
Body forged brass, nickel plated
Ball stainless steel
Stem stainless steel
Seat Teflon® PTFE
Characterized Disc TEFZEL®
Seat 0-ring EPDM
Media Temperature Range
0°F to 250°F [-18°C to +120°C]
(Water)
Max Differential Pressure
50 psi
(Water)
Leakage 0% for A to AB, <2.0% for B to AB
A-port: as stated in chart
Cv Flow Rating

CCV
B-port: 70% of A to AB Cv

ACTUATOR PART # TR24-3-T US TR24-3 US TR24-SR-T US TR24-SR US LRB24-3 LRB24-SR LRX24-MFT


On/Off, On/Off, On/Off,
Control Modulating Modulating Modulating Modulating/MFT
Floating Point Floating Point Floating Point
Manual Override • • • • • • •

150 seconds
Running Time (Motor) 90 seconds 90 seconds 90 seconds 90 seconds 90 seconds 90 seconds
(variable)
3 ft, 18 GA 3 ft, 18 GA 3 ft, 18 GA
screw terminal screw terminal
3 ft, 18 GA 3 ft, 18 GA plenum cable plenum cable plenum cable
Electrical Connection (for 26 to 14 GA (for 26 to 14 GA
plenum cable plenum cable with ½” conduit with ½” conduit with ½” conduit
wire) wire)
connector connector connector
3-Way Mixing/Diverting
Close-Off
Size Body Pressure
Model # Cv Pressure
[mm] Rating [psi]
[psi]
B307 0.3 200 $306 $318 $441 $455 $378 $507 $644
B308 0.46 200 $306 $318 $441 $455 $378 $507 $644
B309 0.8 200 $306 $318 $441 $455 $378 $507 $644
B310 1.2 200 $308 $321 $443 $457 $380 $511 $646
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

½”
B311 1.9 200 $308 $321 $443 $457 $380 $511 $646
[15]
B312 3 200 $314 $329 $449 $463 $389 $521 $655
B313 4.7 200 $316 $331 $451 $466 $394 $526 $661
B315 10 200 $316 $331 $451 $466 $402 $532 $668
600
B316* 16 200 $328 $341 $461 $477 $405 $535 $672
All prices are in US Dollars (USD)

B317 4.7 200 $383 $396 $518 $531 $469 $601 $736
B318 7.4 ¾” 200 $384 $397 $519 $532 $472 $603 $738
B320 14 [20] 200 $480 $610 $746
B321* 24 200 $484 $614 $750
B322 7.4 200 $506 $638 $772
1”
B323 10 200 $508 $640 $775
[25]
B325* 30 200 $514 $644 $779

*Models without characterizing discs.


For corrected Cvs with piping reduction factor refer to page 11-5.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

11-13
B3 Series Characterized Control Valves with Non Fail-Safe Actuators
3-way Valve with Stainless Steel Ball and Stem, NPT Female Ends

Valve Specifications
chilled , hot water, up to 60%
Service
glycol
A-port equal percentage, B-port
Flow Characteristic
modified linear for constant flow Visit www.belimo.us for additional non fail-safe
Controllable Flow Range 75° actuator options including 120V and -S models.
End Fitting NPT female
Body forged brass, nickel plated
Ball stainless steel
Stem stainless steel
Seat Teflon® PTFE
Characterized Disc stainless steel
Seat 0-ring EPDM
Media Temperature Range
0°F to 250°F [-18°C to +120°C]
(Water)
Max Differential Pressure
50 psi
(Water)
Leakage 0% for A to AB, <2.0% for B to AB
A-port: as stated in chart
Cv Flow Rating
B-port: 70% of A to AB Cv
CCV

ACTUATOR PART # ARB24-3 ARB24-SR ARX24-MFT


Control On/Off, Floating Point Modulating Modulating/MFT
Manual Override • • •
Running Time (Motor) 90 seconds 90 seconds 150 seconds (variable)
3 ft, 18 GA plenum cable with 3 ft, 18 GA plenum cable with 3 ft, 18 GA plenum cable with
Electrical Connection
½” conduit connector ½” conduit connector ½” conduit connector
3-Way Mixing/Diverting
Close-Off
Size Body Pressure
Model # Cv Pressure
[mm] Rating [psi]
[psi]
B329 10 200 $592 $700 $813
1¼”
B330 19 200 $598 $703 $820
[32]
B331 25 200 $752 $900 $975
B338 19 200 $762 $910 $984
B339 29 1½” 200 $766 $914 $988
B340 37 [40] 200 $768 $916 $990
B341 46 400 200 $772 $920 $994
B347 29 200 $1,021 $1,168 $1,243

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


B348 37 200 $1,024 $1,171 $1,246
B349 46 2” 200 $1,024 $1,171 $1,246
B350 57 [50] 200 $1,030 $1,178 $1,252
B351 68 200 $1,038 $1,185 $1,259
B352 83 200 $1,057 $1,196 $1,300

All prices are in US Dollars (USD)

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

11-14
B2 Series Characterized Control Valves with Fail-Safe Actuators
2-way Valve with Stainless Steel Ball and Stem, NPT Female Ends

Valve Specifications
chilled , hot water, up to 60%
Service
glycol
Flow Characteristic equal percentage
Controllable Flow Range 75° Visit www.belimo.us for additional fail-safe
End Fitting NPT female actuator options including 120V and -S models.
Body forged brass, nickel plated
Ball stainless steel
Stem stainless steel
Seat Teflon® PTFE
Characterized Disc TEFZEL®
Seat 0-ring EPDM
Media Temperature Range
0°F to 250°F [-18°C to +120°C]
(Water)
Max Differential Pressure
50 psi
(Water)
Leakage 0%

CCV
ACTUATOR PART # TFRB24 TFRB24-3 TFRB24-SR TFRX24-MFT LF24 US LF24-3 US LF24-SR US LF24-MFT US
Modulating/ Modulating/
Control On/Off Floating Point Modulating On/Off Floating Point Modulating
MFT MFT
150 seconds 150 seconds
Running Time (Motor) <75 seconds 90 seconds 90 seconds 75 seconds 150 seconds 150 seconds
(variable) (variable)
Running Time (Fail-Safe) 75 seconds <25 seconds <25 seconds <25 seconds <25 seconds <25 seconds <25 seconds <25 seconds
3 ft, 18 GA 3 ft, 18 GA 3 ft, 18 GA 3 ft, 18 GA 3 ft, 18 GA 3 ft, 18 GA 3 ft, 18 GA 3 ft, 18 GA
appliance plenum plenum plenum appliance plenum plenum appliance
Electrical Connection cable with cable with cable with cable with cable with cable with cable with cable with
½” conduit ½” conduit ½” conduit ½” conduit ½” conduit ½” conduit ½” conduit ½” conduit
connector connector connector connector connector connector connector connector
2-Way
Close-Off
Size Body Pressure
Model # Cv Pressure
[mm] Rating [psi]
[psi]
B207 0.3 200 $420 $480 $516 $601 $485 $609 $626 $728
B208 0.46 200 $420 $480 $516 $601 $485 $609 $626 $728
B209 0.8 200 $420 $480 $516 $601 $485 $609 $626 $728
B210 1.2 200 $424 $483 $519 $604 $488 $612 $631 $732
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

B211 1.9 ½” 200 $424 $483 $519 $604 $488 $612 $631 $732
B212 3 [15] 200 $432 $491 $527 $612 $494 $618 $637 $739
B213 4.7 200 $435 $493 $529 $614 $496 $620 $639 $741
B214 7.4 200 $438 $495 $531 $616 $500 $624 $642 $745
B215 10 200 $438 $495 $531 $616 $496 $620 $639 $741
All prices are in US Dollars (USD)

B216* 16 200 $439 $496 $532 $617 $500 $624 $642 $745
B217 4.7 600 200 $485 $543 $578 $664 $545 $670 $688 $790
B218 7.4 200 $487 $545 $580 $667 $549 $674 $691 $793
¾”
B219 10 200 $485 $543 $578 $664 $551 $676 $693 $795
[20]
B220* 14 200 $492 $551 $587 $673 $554 $678 $695 $797
B221* 24 200 $558 $681 $699 $801
B222 7.4 200 $563 $686 $705 $806
B223 10 1” 200 $569 $693 $711 $813
B224 19 [25] 200 $579 $705 $722 $825
B225* 30 200 $587 $711 $728 $831
B229 10 1¼” 200 $598 $722 $740 $841
B230* 19 [32] 200 $601 $724 $743 $844

*Models without characterizing discs.


For corrected Cvs with piping reduction factor refer to page 11-5.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

11-15
B2 Series Characterized Control Valves with Fail-Safe Actuators
2-way Valve with Stainless Steel Ball and Stem, NPT Female Ends

Valve Specifications
chilled , hot water, up to 60%
Service
glycol
Flow Characteristic equal percentage
Controllable Flow Range 75° Visit www.belimo.us for additional fail-safe
End Fitting NPT female actuator options including 120V and -S models.
Body forged brass, nickel plated
Ball stainless steel
Stem stainless steel
Seat Teflon® PTFE
Characterized Disc TEFZEL® or stainless steel
Seat 0-ring EPDM
Media Temp. Range
0°F to 250°F [-18°C to +120°C]
1.25” - 2”
Media Temp. Range
0°F to 212°F [-18°C to 100°C]
2.5” - 3”
Max Differential Pressure
50 psi
1.25” - 2”
Max Differential Pressure
30 psi
2.5” - 3”
CCV

Leakage 0%

ACTUATOR PART # AFRB24 AFRB24-SR AFRX24-MFT


Control On/Off Modulating Modulating/MFT
Manual Override • • •
Running Time (Motor) 75 seconds 95 seconds 150 seconds (variable)
Running Time (Fail-Safe) < 20 seconds < 20 seconds < 20 seconds
3 ft, 18 GA appliance cable with 3 ft, 18 GA appliance cable with 3 ft, 18 GA plenum cable with
Electrical Connection
½” conduit connector ½” conduit connector ½” conduit connector
2-Way
Close-Off
Size Body Pressure
Model # Cv Pressure
[mm] Rating [psi]
[psi]
B231 25 1¼” 200 $692 $872 $993
B232* 37 [32] 200 $694 $874 $995
B238 19 200 $699 $878 $1,001
1½”
B239 29 200 $701 $880 $1,003
[40]
B240* 37 200 $703 $882 $1,005
B248 29 200 $976 $1,155 $1,214
B249 46 200 $986 $1,166 $1,226

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


B250* 57 200 $995 $1,176 $1,237
2”
B251 65 200 $1,214 $1,375
[50]
B252 85 200 $1,294 $1,456
400
B253 120 200 $1,371 $1,532
B254* 240 200 $1,375 $1,537

All prices are in US Dollars (USD)


B261 60 100 $1,379 $1,541
B262 75 100 $1,443 $1,604
2½”
B263 110 100 $1,516 $1,677
[65]
B264 150 100 $1,551 $1,712
B265* 210 100 $1,719 $1,878
B277 70 100 $1,569 $1,730
3”
B278 130 100 $1,651 $1,813
[80]
B280* 170 100 $1,975 $2,135

*Models without characterizing discs.


For corrected Cvs with piping reduction factor refer to page 11-5.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

11-16
B3 Series Characterized Control Valves with Fail-Safe Actuators
3-way Valve with Stainless Steel Ball and Stem, NPT Female Ends

Valve Specifications
chilled , hot water, up to 60%
Service
glycol
A-port equal percentage, B-port
Flow Characteristic
modified linear for constant flow Visit www.belimo.us for additional fail-safe
Controllable Flow Range 75° actuator options including 120V and -S models.
End Fitting NPT female
Body forged brass, nickel plated
Ball stainless steel
Stem stainless steel
Seat Teflon® PTFE
Characterized Disc TEFZEL® or stainless steel
Seat 0-ring EPDM
Media Temperature Range
0°F to 250°F [-18°C to +120°C]
(Water)
Max Differential Pressure
50 psi
(Water)
Leakage 0% for A to AB, <2.0% for B to AB
A-port: as stated in chart
Cv Flow Rating
B-port: 70% of A to AB Cv

CCV
ACTUATOR PART # TFRB24 TFRB24-3 TFRB24-SR TFRX24-MFT LF24 US LF24-3 US LF24-SR US LF24-MFT US
Modulating/ Modulating/
Control On/Off Floating Point Modulating On/Off Floating Point Modulating
MFT MFT

150 seconds 150 seconds


Running Time (Motor) <75 seconds 90 seconds 90 seconds 75 seconds 150 seconds 150 seconds
(variable) (variable)

Running Time (Fail-Safe) 75 seconds <25 seconds <25 seconds <25 seconds <25 seconds <25 seconds <25 seconds <25 seconds
3 ft, 18 GA 3 ft, 18 GA 3 ft, 18 GA 3 ft, 18 GA 3 ft, 18 GA 3 ft, 18 GA 3 ft, 18 GA 3 ft, 18 GA
appliance plenum plenum plenum appliance plenum plenum appliance
Electrical Connection cable with cable with cable with cable with cable with cable with cable with cable with
½” conduit ½” conduit ½” conduit ½” conduit ½” conduit ½” conduit ½” conduit ½” conduit
connector connector connector connector connector connector connector connector
3-Way Mixing/Diverting
Close-Off
Size Body Pressure
Model # Cv Pressure
[mm] Rating [psi]
[psi]
B307 0.3 200 $506 $587 $601 $689 $567 $694 $724 $798
B308 0.46 200 $506 $587 $601 $689 $567 $694 $724 $798
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

B309 0.8 200 $506 $587 $601 $689 $567 $694 $724 $798
B310 1.2 200 $508 $589 $603 $691 $569 $696 $726 $801
½”
B311 1.9 200 $516 $595 $608 $696 $569 $696 $726 $801
[15]
B312 3 200 $523 $603 $615 $705 $581 $710 $740 $814
B313 4.7 200 $525 $605 $617 $707 $585 $712 $743 $816
All prices are in US Dollars (USD)

B315 10 200 $525 $605 $617 $707 $587 $715 $745 $819
600
B316* 16 200 $524 $604 $616 $706 $589 $717 $747 $822
B317 4.7 200 $572 $652 $665 $754 $620 $749 $779 $853
B318 7.4 ¾” 200 $572 $652 $665 $754 $633 $760 $790 $864
B320 14 [20] 200 $640 $767 $797 $872
B321* 24 200 $645 $771 $802 $876
B322 7.4 200 $660 $788 $817 $892
1”
B323 10 200 $668 $795 $826 $900
[25]
B325* 30 200 $674 $801 $831 $905

*Models without characterizing discs.


For corrected Cvs with piping reduction factor refer to page 11-5.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

11-17
B3 Series Characterized Control Valves with Fail-Safe Actuators
3-way Valve with Stainless Steel Ball and Stem, NPT Female Ends

Valve Specifications
chilled , hot water, up to 60%
Service
glycol
A-port equal percentage, B-port
Flow Characteristic
modified linear for constant flow Visit www.belimo.us for additional fail-safe
Controllable Flow Range 75° actuator options including 120V and -S models.
End Fitting NPT female
Body forged brass, nickel plated
Ball stainless steel
Stem stainless steel
Seat Teflon® PTFE
Characterized Disc stainless steel
Seat 0-ring EPDM
Media Temperature Range
0°F to 250°F [-18°C to +120°C]
(Water)
Max Differential Pressure
50 psi
(Water)
Leakage 0% for A to AB, <2.0% for B to AB
A-port: as stated in chart
Cv Flow Rating
B-port: 70% of A to AB Cv
CCV

ACTUATOR PART # AFRB24 AFRB24-SR AFRX24-MFT


Control On/Off Modulating Modulating/MFT
Manual Override • • •
Running Time (Motor) 75 seconds 95 seconds 150 seconds (variable)
Running Time (Fail-Safe) < 20 seconds < 20 seconds < 20 seconds
3 ft, 18 GA appliance cable with 3 ft, 18 GA appliance cable with 3 ft, 18 GA plenum cable with
Electrical Connection
½” conduit connector ½” conduit connector ½” conduit connector
3-Way Mixing/Diverting
Close-Off
Size Body Pressure
Model # Cv Pressure
[mm] Rating [psi]
[psi]
B329 10 200 $789 $947 $986
1¼”
B330 19 200 $795 $962 $1,000
[32]
B331 25 200 $962 $1,157 $1,205
B338 19 200 $978 $1,172 $1,220
B339 29 1½” 200 $980 $1,174 $1,222
B340 37 [40] 200 $986 $1,181 $1,229
B341 46 200 $1,176 $1,371 $1,419

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


400
B347 29 200 $1,386 $1,583 $1,630
B348 37 200 $1,390 $1,586 $1,633
B349 46 2” 200 $1,392 $1,588 $1,635
B350 57 [50] 200 $1,398 $1,593 $1,641
B351 68 200 $1,595 $1,789 $1,837

All prices are in US Dollars (USD)


B352 83 200 $1,665 $1,860 $1,908

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

11-18
B6 Series Characterized Control Valves with Non Fail-Safe Actuators
2-way Valve with Stainless Steel Ball and Stem, Flanged Ends

Valve Specifications
chilled , hot water, up to 60%
Service
glycol
Flow Characteristic equal percentage
Visit www.belimo.us for additional non fail-safe
Controllable Flow Range 75°
pattern to mate with ANSI 125 actuator options including 120V and -S models.
End Fitting
flange, flat face, ANSI 250 flange
Body cast iron - GG25
Ball stainless steel
Stem stainless steel
Seat Teflon® PTFE
Characterized Disc stainless steel
Seat 0-ring EPDM
Media Temperature Range
0°F to 250°F [-18°C to +120°C]
(Water)
Max Differential Pressure
50 psi
(Water)
Leakage 0%

CCV
ACTUATOR PART # ARB24-3-5-14 ARX24-MFT GRB24-3-5-14 GRX24-MFT
Control On/Off, Floating Point Modulating/MFT On/Off, Floating Point Modulating/MFT
Manual Override • • • •
Running Time (Motor) 90 seconds 150 seconds (variable) 150 seconds 150 seconds (variable)
3 ft, 18 GA plenum cable with 3 ft, 18 GA plenum cable with 3 ft, 18 GA plenum cable with 3 ft, 18 GA plenum cable with
Electrical Connection
½” conduit connector ½” conduit connector ½” conduit connector ½” conduit connector
2-Way ANSI 125
Close-Off
Size Body Pressure
Model # Cv Pressure
[mm] Rating [psi]
[psi]
B6250S-070 70 2½” 100 $2,002 $2,124
B6250S-110 110 [65] 100 $2,090 $2,213
B6300S-110 110 3” [80] ANSI 125, 100 $2,192 $2,449
Standard
B6400S-186 186 4” [100] 100 $2,535 $2,718
Class B
B6500S-290 290 5” [125] 100 $3,675 $3,774
B6600S-400 400 6” [150] 100 $4,666 $4,764

2-Way ANSI 250


U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

Body Close-Off
Size
Model # Cv Pressure Pressure
[mm]
Rating [psi] [psi]
B6250S-070-250 70 2½” 100 $2,534 $2,688
B6250S-110-250 110 [65] 100 $2,646 $2,802
All prices are in US Dollars (USD)

B6300S-110-250 110 3” [80] 100 $2,774 $3,101


ANSI 250
B6400S-186-250 186 4” [100] 100 $3,208 $3,441
B6500S-290-250 290 5” [125] 100 $4,651 $4,778
B6600S-400-250 400 6” [150] 100 $5,906 $6,031

Add the P… pre-set MFT configuration number and list price to the actuator when ordering, as needed. See page 11-8 for more details.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

11-19
B6 Series Characterized Control Valves with Fail-Safe Actuators
2-way Valve with Stainless Steel Ball and Stem, Flanged Ends

Valve Specifications
chilled , hot water, up to 60%
Service
glycol
Flow Characteristic equal percentage
Controllable Flow Range 75° Visit www.belimo.us for additional fail-safe actuator options
End Fitting
pattern to mate with ANSI 125 including 120V and -S models.
flange, flat face, ANSI 250 flange
Body cast iron - GG25
Ball stainless steel
Stem stainless steel
Seat Teflon® PTFE
Characterized Disc stainless steel
Seat 0-ring EPDM
Media Temperature Range
0°F to 250°F [-18°C to +120°C]
(Water)
Max Differential Pressure
50 psi
(Water)
Leakage 0%
CCV

ACTUATOR PART # AFRX24 AFRX24-MFT GKRX24-3 GKRX24-MFT


Control On/Off Modulating/MFT On/Off, Floating Point Modulating/MFT
Manual Override • • • •
Running Time (Motor) 75 seconds 150 seconds (variable) 150 seconds (variable) 150 seconds (variable)
Running Time (Fail-Safe) < 20 seconds < 20 seconds 35 seconds 35 seconds
3 ft, 18 GA appliance cable with 3 ft, 18 GA plenum cable with 3 ft, 18 GA plenum cable with 3 ft, 18 GA plenum cable with
Electrical Connection
½” conduit connector ½” conduit connector ½” conduit connector ½” conduit connector
2-Way ANSI 125
Close-Off
Size Body Pressure
Model # Cv Pressure
[mm] Rating [psi]
[psi]
B6250S-070 70 2½” 100 $2,041 $2,305
B6250S-110 110 [65] 100 $2,134 $2,397
B6300S-110 110 3” [80] ANSI 125, 100 $2,304 $2,565
Standard
B6400S-186 186 4” [100] 100 $2,855 $3,084
Class B
B6500S-290 290 5” [125] 100 $4,068 $4,228
B6600S-400 400 6” [150] 100 $4,982 $5,203

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


2-Way ANSI 250
Body Close-Off
Size
Model # Cv Pressure Pressure
[mm]
Rating [psi] [psi]
B6250S-070-250 70 2½” 100 $2,534 $2,688
B6250S-110-250 110 [65] 100 $2,646 $2,802

All prices are in US Dollars (USD)


B6300S-110-250 110 3” [80] 100 $2,774 $3,101
ANSI 250
B6400S-186-250 186 4” [100] 100 $3,208 $3,441
B6500S-290-250 290 5” [125] 100 $4,651 $4,778
B6600S-400-250 400 6” [150] 100 $5,906 $6,031

AFRX24 MFT is customizable. Add the P… pre-set MFT configuration number and list price to the actuator when ordering, as needed. See page 11-8 for more details.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

11-20
B2 Series Characterized Control Valves with NEMA 4X Non Fail-Safe Actuators
2-way Valve with Stainless Steel Ball and Stem, NPT Female Ends
Valve Specifications
chilled , hot water, up to 60%
Service
glycol
Flow characteristic equal percentage
Controllable Flow Range 75°
End Fitting NPT female
Body forged brass, nickel plated
Ball stainless steel
Stem stainless steel
Seat Teflon® PTFE
Characterized Disc TEFZEL® or stainless steel
Seat 0-ring EPDM
Media Temp. Range 0.5” - 2” 0°F to 250°F [-18°C to +120°C]
Media Temp. Range 2.5” - 3” 0°F to 212°F [-18°C to 100°C]
Max Differential Pressure
50 psi
0.5” - 2”
Max Differential Pressure
30 psi
2.5” - 3”

CCV
Leakage 0%
ACTUATOR PART # NRX24-3-T N4 NRX24-SR-T N4 NRX24-MFT-T N4 ARX24-3-T N4 ARX24-SR-T N4 ARX24-MFT-T N4
Control On/Off, Floating Point Modulating Modulating/MFT On/Off, Floating Point Modulating Modulating/MFT
Manual Override • • • • • •
150 seconds 150 seconds
Running Time (Motor) 90 seconds 90 seconds 90 seconds 90 seconds
(variable) (variable)
Electrical Connection terminal block terminal block terminal block terminal block terminal block terminal block
2-Way
Close-Off
Size Body Pressure
Model # Cv Pressure
[mm] Rating [psi]
[psi]
B207 0.3 200 $648 $759 $904
B208 0.46 200 $648 $759 $904
B209 0.8 200 $648 $759 $904
B210 1.2 200 $651 $762 $907
B211 1.9 ½” 200 $651 $762 $907
B212 3 [15] 200 $651 $762 $907
B213 4.7 200 $655 $766 $912
B214 7.4 200 $662 $772 $918
B215 10 200 $668 $779 $924
B216* 16 200 $668 $779 $924
B217 4.7 600 200 $705 $815 $960
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

B218 7.4 200 $708 $819 $964


¾”
B219 10 200 $710 $822 $966
[20]
B220* 14 200 $716 $827 $972
B221* 24 200 $720 $831 $977
B222 7.4 200 $725 $836 $982
B223 10 1” 200 $730 $841 $987
All prices are in US Dollars (USD)

B224 19 [25] 200 $730 $841 $987


B225* 30 200 $736 $846 $991
B229 10 200 $775 $885 $1,031
B230* 19 1¼” 200 $778 $889 $1,033
B231 25 [32] 200 $845 $1,012 $1,079
B232* 37 200 $847 $1,014 $1,081
B238 19 200 $855 $1,022 $1,090
1½”
B239 29 200 $855 $1,022 $1,090
[40]
B240* 37 200 $861 $1,027 $1,095
B248 29 200 $884 $1,052 $1,119
B249 46 200 $1,007 $1,173 $1,242
B250* 57 200 $1,010 $1,176 $1,244
2”
B251 65 200 $1,012 $1,178 $1,246
[50]
B252 85 200 $1,316 $1,481 $1,550
400
B253 120 200 $1,393 $1,559 $1,628
B254* 240 200 $1,476 $1,643 $1,711
B261 60 100 $1,490 $1,656 $1,724
B262 75 100 $1,492 $1,658 $1,726
2½”
B263 110 100 $1,495 $1,660 $1,728
[65]
B264 150 100 $1,573 $1,740 $1,809
B265* 210 100 $1,651 $1,818 $1,887
B277 70 100 $1,670 $1,835 $1,903
3”
B278 130 100 $1,749 $1,916 $1,985
[80]
B280* 170 100 $1,817 $1,984 $2,050
*Models without characterizing discs. For corrected Cvs with piping reduction factor refer to page 11-5.

Heater option for NEMA 4X products has a list price adder of $500.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

11-21
B3 Series Characterized Control Valves with NEMA 4X Non Fail-Safe Actuators
3-way Valve with Stainless Steel Ball and Stem, NPT Female Ends

Valve Specifications
chilled , hot water, up to 60%
Service
glycol
A-port equal percentage, B-port
Flow Characteristic
modified linear for constant flow
Controllable Flow Range 75°
End Fitting NPT female
Body forged brass, nickel plated
Ball stainless steel
Stem stainless steel
Seat Teflon® PTFE
Characterized Disc TEFZEL® or stainless steel
Seat 0-ring EPDM
Media Temperature Range
0°F to 250°F [-18°C to +120°C]
(Water)
Max Differential Pressure
50 psi
(Water)
Leakage 0% for A to AB, <2.0% for B to AB
A-port: as stated in chart
Cv Flow Rating
B-port: 70% of A to AB Cv
CCV

ACTUATOR PART # NRX24-3-T N4 NRX24-SR-T N4 NRX24-MFT-T N4 ARX24-3-T N4 ARX24-SR-T N4 ARX24-MFT-T N4
Control On/Off, Floating Point Modulating Modulating/MFT On/Off, Floating Point Modulating Modulating/MFT
Manual Override • • • • • •
150 seconds 150 seconds
Running Time (Motor) 90 seconds 90 seconds 90 seconds 90 seconds
(variable) (variable)
Electrical Connection terminal block terminal block terminal block terminal block terminal block terminal block
3-Way Mixing/Diverting
Close-Off
Size Body Pressure
Model # Cv Pressure
[mm] Rating [psi]
[psi]
B307 0.3 200 $700 $838 $989
B308 0.46 200 $700 $838 $989
B309 0.8 200 $700 $838 $989
B310 1.2 200 $702 $840 $991
½”
B311 1.9 200 $702 $840 $991
[15]
B312 3 200 $705 $842 $993
B313 4.7 200 $705 $842 $993

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


B315 10 200 $708 $846 $996
600
B316* 16 200 $706 $844 $994
B317 4.7 200 $796 $895 $1,237
B318 7.4 ¾” 200 $798 $897 $1,239
B320 14 [20] 200 $803 $901 $1,243

All prices are in US Dollars (USD)


B321* 24 200 $806 $904 $1,246
B322 7.4 200 $823 $966 $1,126
1”
B323 10 200 $825 $968 $1,128
[25]
B325* 30 200 $834 $979 $1,138
B329 10 200 $935 $1,031 $1,159
1¼”
B330 19 200 $939 $1,035 $1,165
[32]
B331 25 200 $1,094 $1,247 $1,321
B338 19 200 $1,105 $1,257 $1,334
B339 29 1½” 200 $1,107 $1,259 $1,339
B340 37 [40] 200 $1,109 $1,261 $1,342
B341 46 400 200 $1,111 $1,265 $1,354
B347 29 200 $1,362 $1,515 $1,571
B348 37 200 $1,365 $1,517 $1,573
B349 46 2” 200 $1,367 $1,519 $1,583
B350 57 [50] 200 $1,372 $1,524 $1,587
B351 68 200 $1,378 $1,531 $1,589
B352 83 200 $1,383 $1,537 $1,593

Models without characterizing discs.


For corrected Cvs with piping reduction factor refer to page 11-5.

Heater option for NEMA 4X products has a list price adder of $500.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

11-22
B2, B3 Series Characterized Control Valves with NEMA 4X Fail-Safe Actuators
2-way and 3-way Valve with Stainless Steel Ball and Stem, NPT Female Ends

Valve Specifications
chilled , hot water, up to 60%
Service
glycol
A-port equal percentage, B-port
Flow Characteristic
modified linear for constant flow
Controllable Flow Range 75°
End Fitting NPT female
Body forged brass, nickel plated
Ball stainless steel
Stem stainless steel
Seat Teflon® PTFE
Characterized Disc TEFZEL® or stainless steel
Seat 0-ring EPDM
Media Temp. Range
0°F to 250°F [-18°C to +120°C]
1.25” - 2”
Media Temp. Range
0°F to 212°F [-18°C to 100°C]
2.5” - 3”
Max Differential Pressure
50 psi
1.25” - 2”
Max Differential Pressure

CCV
30 psi
2.5” - 3”
Leakage 0% for A to AB, <2.0% for B to AB
A-port: as stated in chart
Cv Flow Rating
B-port: 70% of A to AB Cv
ACTUATOR PART # AFRX24 N4 AFRX24-MFT N4
Control On/Off Modulating/MFT
Manual Override • •
Running Time (Motor) 75 seconds 150 seconds (variable)
Running Time (Fail-Safe) <20 seconds <20 seconds
Electrical Connection 3 ft, 18 GA appliance cable with ½” conduit connector 3 ft, 18 GA plenum cable with ½” conduit connector
2-Way
Close-Off
Size Body Pressure
Model # Cv Pressure
[mm] Rating [psi]
[psi]
B231 25 1¼” 200 $1,336 $1,746
B232* 37 [32] 200 $1,340 $1,750
B238 19 200 $1,344 $1,755
1½”
B239 29 200 $1,346 $1,757
[40]
B240* 37 200 $1,349 $1,760
B248 29 200 $1,621 $1,816
B249 46 200 $1,632 $1,830
B250* 57 200 $1,642 $1,840
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

2”
B251 65 200 $1,858 $2,057
[50]
B252 85 200 $1,939 $2,137
400
B253 120 200 $2,018 $2,216
B254* 240 200 $2,261 $2,460
B261 60 100 $1,960 $2,159
B262 75 100 $2,039 $2,237
All prices are in US Dollars (USD)

2½”
B263 110 100 $2,120 $2,318
[65]
B264 150 100 $2,197 $2,395
B265* 210 100 $2,365 $2,563
B277 70 100 $2,214 $2,412
3”
B278 130 100 $2,298 $2,497
[80]
B280* 170 100 $2,617 $2,816
3-Way Mixing/Diverting
B329 10 200 $1,549 $1,793
1¼”
B330 19 200 $1,556 $1,802
[32]
B331 25 200 $1,721 $1,965
B338 19 200 $1,737 $1,983
B339 29 1½” 200 $1,739 $1,985
B340 37 [40] 200 $1,745 $1,991
B341 46 400 200 $1,935 $2,179
B347 29 200 $2,143 $2,388
B348 37 200 $2,146 $2,391
B349 46 2” 200 $2,148 $2,393
B350 57 [50] 200 $2,156 $2,400
B351 68 200 $2,352 $2,598
B352 83 200 $2,422 $2,667

*Models without characterizing discs.


For corrected Cvs with piping reduction factor refer to page 11-5.

Heater option for NEMA 4X products has a list price adder of $500.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

11-23
B6 Series Characterized Control Valves with NEMA 4X Non Fail-Safe Actuators
2-way Valve with Stainless Steel Ball and Stem, Flanged Ends

Valve Specifications
chilled , hot water, up to 60%
Service
glycol
Flow Characteristic equal percentage
Controllable Flow Range 75°
pattern to mate with ANSI 125
End Fitting
flange, flat face, ANSI 250 flange
Body cast iron - GG25
Ball stainless steel
Stem stainless steel
Seat Teflon® PTFE
Characterized Disc stainless steel
Seat 0-ring EPDM
Media Temperature Range
0°F to 250°F [-18°C to +120°C]
(Water)
Max Differential Pressure
50 psi
(Water)
Leakage 0%
CCV

ACTUATOR PART # ARX24-3-T N4 ARX24-MFT-T N4 GRX24-3-T N4  GRX24-MFT-T N4


Control On/Off, Floating Point Modulating/MFT On/Off, Floating Point Modulating/MFT
Manual Override • • • •
Running Time (Motor) 90 seconds 150 seconds (variable) 150 seconds 150 seconds (variable)
Electrical Connection terminal block terminal block terminal block terminal block
2-Way ANSI 125
Body Close-Off
Size
Model # Cv Pressure Pressure
[mm]
Rating [psi] [psi]
B6250S-070 70 100 $2,703 $2,959
2½”[65]
B6250S-110 110 100 $2,883 $3,140
B6300S-110 110 3” [80] ANSI 125, 100 $2,889 $3,363
Standard
B6400S-186 186 4” [100] 100 $3,226 $3,665
Class B
B6500S-290 290 5” [125] 100 $4,342 $4,784
B6600S-400 400 6” [150] 100 $4,796 $5,237

2-Way ANSI 250


Body
Close-Off

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


Size Pressure
Model # Cv Pressure
[mm] Rating
[psi]
[psi]
B6250S-070-250 70 100 $3,422 $3,745
2½”[65]
B6250S-110-250 110 100 $3,649 $3,974
B6300S-110-250 110 3” [80] 100 $3,657 $4,258

All prices are in US Dollars (USD)


ANSI 250
B6400S-186-250 186 4” [100] 100 $4,083 $4,640
B6500S-290-250 290 5” [125] 100 $5,496 $6,055
B6600S-400-250 400 6” [150] 100 $6,071 $6,629


Heater option for NEMA 4X products has a list price adder of $500.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

11-24
B6 Series Characterized Control Valves with NEMA 4X Fail-Safe Actuators
2-way Valve with Stainless Steel Ball and Stem, Flanged Ends

Valve Specifications
chilled , hot water, up to 60%
Service
glycol
Flow Characteristic equal percentage
Controllable Flow Range 75°
pattern to mate with ANSI 125
End Fitting
flange, flat face, ANSI 250 flange
Body cast iron - GG25
Ball stainless steel
Stem stainless steel
Seat Teflon® PTFE
Characterized Disc stainless steel
Seat 0-ring EPDM
Media Temperature Range
0°F to 250°F [-18°C to +120°C]
(Water)
Max Differential Pressure
50 psi
(Water)
Leakage 0%

CCV
ACTUATOR PART # AFRX24 N4 AFRX24-MFT N4 GKRX24-3 N4 GKRX24-MFT N4
Control On/Off Modulating/MFT On/Off, Floating Point Modulating/MFT
Manual Override • • • •
Running Time (Motor) 75 seconds 150 seconds (variable) 150 seconds (variable) 150 seconds (variable)
Running Time (Fail-Safe) < 20 seconds < 20 seconds 35 seconds 35 seconds
3 ft, 18 GA appliance cable with 3 ft, 18 GA plenum cable with 3 ft, 18 GA plenum cable with 3 ft, 18 GA plenum cable with
Electrical Connection
½” conduit connector ½” conduit connector ½” conduit connector ½” conduit connector
2-Way ANSI 125
Close-Off
Size Body Pressure
Model # Cv Pressure
[mm] Rating [psi]
[psi]
B6250S-070 70 2½” 100 $2,745 $3,175
B6250S-110 110 [65] 100 $2,991 $3,356
B6300S-110 110 3” [80] ANSI 125, 100 $2,996 $3,580
Standard
B6400S-186 186 4” [100] 100 $3,549 $3,990
Class B
B6500S-290 290 5” [125] 100 $4,668 $5,107
B6600S-400 400 6” [150] 100 $5,337 $5,736
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

2-Way ANSI 250


Body
Close-Off
Size Pressure
Model # Cv Pressure
[mm] Rating
[psi]
[psi]
All prices are in US Dollars (USD)

B6250S-070-250 70 2½” 100 $3,475 $4,020


B6250S-110-250 110 [65] 100 $3,786 $4,248
B6300S-110-250 110 3” [80] 100 $3,792 $4,532
ANSI 250
B6400S-186-250 186 4” [100] 100 $4,493 $5,051
B6500S-290-250 290 5” [125] 100 $5,909 $6,465
B6600S-400-250 400 6” [150] 100 $6,756 $7,261


Heater option for NEMA 4X products has a list price adder of $500.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

11-25
B2 Series Characterized Control Valves
with Quick Running Non Fail-Safe Actuators
2-way Valve with Stainless Steel Ball and Stem, NPT Female Ends
Valve Specifications
chilled , hot water, up to 60%
Service
glycol
Flow Characteristic equal percentage
Controllable Flow Range 75°
End Fitting NPT female
Body forged brass, nickel plated
Ball stainless steel
Stem stainless steel
Seat Teflon® PTFE
Characterized Disc TEFZEL® or stainless steel
Seat 0-ring EPDM
Media Temperature Range
0°F to 250°F [-18°C to +120°C]
(Water)
Max Differential Pressure
50 psi
(Water)
Leakage 0%
CCV

ACTUATOR PART # LRQX24-MFT NRQX24-MFT ARQX24-MFT


Control Modulating/MFT Modulating/MFT Modulating/MFT
Manual Override • • •
Running Time (Motor) 4 seconds (variable) 4 seconds (variable) 10 seconds (variable)
3 ft, 18 GA plenum cable with 3 ft, 18 GA plenum cable with 3 ft, 18 GA plenum cable with
Electrical Connection
½” conduit connector ½” conduit connector ½” conduit connector
2-Way
Close-Off
Size Body Pressure
Model # Cv Pressure
[mm] Rating [psi]
[psi]
B207 0.3 200 $748
B208 0.46 200 $748
B209 0.8 200 $748
B210 1.2 200 $752
B211 1.9 ½” 200 $752
B212 3 [15] 200 $758
B213 4.7 200 $768
B214 7.4 200 $775
B215 10 200 $781

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


B216* 16 200 $783
B217 4.7 600 200 $796
B218 7.4 200 $798
¾”
B219 10 200 $801
[20]
B220* 14 200 $803

All prices are in US Dollars (USD)


B221* 24 200 $806
B222 7.4 200 $834
B223 10 1” 200 $840
B224 19 [25] 200 $847
B225* 30 200 $851
B229 10 200 $874
B230* 19 1¼” 200 $878
B231 25 [32] 200 $914
B232* 37 200 $935
B238 19 200 $935
1½”
B239 29 200 $939
[40]
B240* 37 200 $941
B248 29 200 $1,075
400
B249 46 200 $1,079
B250* 57 200 $1,089
2”
B251 65 200 $1,374
[50]
B252 85 200 $1,457
B253 120 200 $1,531
B254* 240 200 $1,750

*Models without characterizing discs.


For corrected Cvs with piping reduction factor refer to page 11-5.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

11-26
B3 Series Characterized Control Valves
with Quick Running Non Fail-Safe Actuators
3-way Valve with Stainless Steel Ball and Stem, NPT Female Ends
Valve Specifications
chilled , hot water, up to 60%
Service
glycol
A-port equal percentage, B-port
Flow Characteristic
modified linear for constant flow
Controllable Flow Range 75°
End Fitting NPT female
Body forged brass, nickel plated
Ball stainless steel
Stem stainless steel
Seat Teflon® PTFE
Characterized Disc TEFZEL® or stainless steel
Seat 0-ring EPDM
Media Temperature Range
0°F to 250°F [-18°C to +120°C]
(Water)
Max Differential Pressure
50 psi
(Water)
Leakage 0% for A to AB, <2.0% for B to AB
A-port: as stated in chart
Cv Flow Rating
B-port: 70% of A to AB Cv

CCV
ACTUATOR PART # LRQX24-MFT ARQX24-MFT
Control Modulating/MFT Modulating/MFT
Manual Override • •
Running Time (Motor) 4 seconds (variable) 10 seconds (variable)
Electrical Connection 3 ft, 18 GA plenum cable with ½” conduit connector 3 ft, 18 GA plenum cable with ½” conduit connector
3-Way Mixing/Diverting
Body Close-Off
Size
Model # Cv Pressure Pressure
[mm]
Rating [psi] [psi]
B307 0.3 200 $836
B308 0.46 200 $836
B309 0.8 200 $836
B310 1.2 200 $838
½”
B311 1.9 200 $838
[15]
B312 3 200 $840
B313 4.7 200 $851
B315 10 200 $853
600
B316* 16 200 $852
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

B317 4.7 200 $878


B318 7.4 ¾” 200 $882
B320 14 [20] 200 $884
B321* 24 200 $884
B322 7.4 200 $982
1”
All prices are in US Dollars (USD)

B323 10 200 $984


[25]
B325* 30 200 $988
B329 10 200 $1,002
1¼”
B330 19 200 $1,048
[32]
B331 25 200 $1,202
B338 19 200 $1,212
B339 29 1½” 200 $1,214
B340 37 [40] 200 $1,217
B341 46 400 200 $1,222
B347 29 200 $1,471
B348 37 200 $1,473
B349 46 2” 200 $1,475
B350 57 [50] 200 $1,479
B351 68 200 $1,487
B352 83 200 $1,496

*Models without characterizing discs.


For corrected Cvs with piping reduction factor refer to page 11-5.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

11-27
LR Series Non Fail-Safe Actuators
Custom, Non Fail-Safe Actuator, 45 in-lbs Minimum Torque

Actuator Specifications
Torque 45 in-lbs [5 Nm]
Ambient Temperature -22°F to +122°F
[-30°C to +50°C]
Angle of Rotation max. 90°, adjustable with
mechanical stop
electronically variable
Position Indication handle
Manual Override external push-button
Direction of Rotation reversible with switch
Dimensions 6.18” x 2.6” x 2.34”
[157 x 66 x 59.4 mm]
Electrical Connection 18 GA plenum rated cable, ½”
conduit fitting terminal strip
(-T) models
Overload Protection electronic throughout rotation NEW
Auxiliary Switch (-S) models: 1 SPDT, 3A (0.5A
inductive) @ 250V adjustable
5° to 85°
Housing NEMA 2/IP54
CCV

Agency Listings cULus acc. to UL 60730-1A/- MFT= 2-10 VDC Default, or Set, Modify, Read: All actuators
2-14, CAN/CSA E60730-1:02, • Control (PWM, VDC range, Floating Point) have BDCM
CSA C22.2 No. 24-93, CE acc. • Feedback (0-10 VDC, 0-5 VDC, 2-10 VDC, Variable)
to 2006/95/EC and 89/336/EEC • Motion (run time)
 Variable with MFT

Running
VA Cable Re-order List
Model Control Input Feedback Power Supply Time(s)
Rating Length Number Price‡
[Default]
LRB24-3 On/Off, Floating Point Add on 24 VAC/DC 90 2 3 ft. N/A** $234
LRB24-3-S On/Off, Floating Point Add on 24 VAC/DC 90 2 3 ft. N/A** $330
LRB24-3-T On/Off, Floating Point Add on 24 VAC/DC 90 2 N/A N/A** $221
LRB120-3 On/Off, Floating Point Add on 100-240 VAC 90 4 3 ft. N/A** $293
LRB24-SR 2-10 VDC (4-20mA*) 2-10 VDC 24 VAC/DC 90 4.5 3 ft. N/A** $347
LRB24-SR-T 2-10 VDC (4-20mA*) 2-10 VDC 24 VAC/DC 90 4.5 N/A N/A** $339
LRB120-SR 2-10 VDC (4-20mA*) 2-10 VDC 100-240 VAC 90 4 3 ft. N/A** $392

MFT VERSION
LRB24-MFT Various Various 24 VAC/DC 90 5 3 ft. N/A** $459

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


IOT VERSION NEW

LRB24-IP 2-10 VDC (4-20mA*) Various 24 VAC/DC 90 5 3 ft. N/A** $626


See page 11-8 for actuator customizing and available P-Codes.
‡ Prices do not reflect additional programming code surcharge.
*With 500 Ω resistor- ZG-R01.
** Re-order numbers only available for customizable “X” version actuators (e.g. LRX24-3).

All prices are in US Dollars (USD)


The P-Code programs the actuator for the desired Control Input, Feedback and Running Time.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

11-28
AR Series Non Fail-Safe Actuators
Custom Non Fail-Safe Actuator, 180 in-lbs Minimum Torque

Actuator Specifications
Torque 180 in-lbs [20 Nm]
Ambient Temperature -22°F to +122°F
[-30°C to +50°C]
Angle of Rotation max 90°, adjustable with
mechanical stop electronically
variable
Position Indication handle
Manual Override external push-button
Direction of Rotation reversible with switch
Dimensions 7.47” x 3.45” x 2.52”
[189.8 x 88 x 64 mm]
Electrical Connection 18 GA plenum rated cable, ½”
conduit connector
Overload Protection electronic throughout rotation
Auxiliary Switch(es) (-S) models: 1 SPDT, 3A (0.5A
inductive) @ 250V adjustable NEW
5° to 85°
Housing NEMA 2/IP54

CCV
Agency Listings cULus acc. to UL 60730-1A/-
2-14, CAN/CSA E60730-1:02, MFT= 2-10 VDC Default, or Set, Modify, Read: All Actuators
CSA C22.2 No. 24-93, CE acc. • Control (PWM, VDC range, Floating Point) have BDCM
to 2006/95/EC and 89/336/EEC • Feedback (0-10 VDC, 0-5 VDC, 2-10 VDC, Variable)
• Motion (run time)
 Variable with MFT

Power Running Cable List


Model Control Input Feedback VA Rating Re-order Number
Supply Time(s) Length Price

ARB24-3 On/Off, Floating Point Add on 24 VAC/DC 90 5.5 3 ft. N/A** $421
ARB24-3-S On/Off, Floating Point Add on 24 VAC/DC 90 5.5 3 ft. N/A** $543
ARB24-3-T On/Off, Floating Point Add on 24 VAC/DC 90 5.5 N/A N/A** $403
ARB120-3 On/Off, Floating Point Add on 100-240 VAC 90 7 3 ft. N/A** $486
ARB24-SR 2-10 VDC (4-20mA*) 2-10 VDC 24 VAC/DC 90 5 3 ft. N/A** $619
ARB24-SR-T 2-10 VDC (4-20mA*) 2-10 VDC 24 VAC/DC 90 5 N/A N/A** $594
ARB120-SR 2-10 VDC (4-20mA*) 2-10 VDC 100-240 VAC 90 7.5 3 ft. N/A** $690

MFT VERSIONS
ARB24-MFT Various Various 24 VAC/DC 90 6 3 ft. N/A** $614
ARX24-MFT95 0 to 135Ω Various 24 VAC/DC 150 6 3 ft. AR0L0 0C3 R01 $631
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

IOT VERSION NEW

ARB24-IP 2-10 VDC (4-20mA*) Various 24 VAC/DC 90 6 3 ft. N/A** $750


See page 11-8 for actuator customizing and available P-Codes.
‡ Prices do not reflect additional programming code surcharge.
*With 500 Ω resistor- ZG-R01.
All prices are in US Dollars (USD)

** Re-order numbers only available for customizable “X” version actuators (e.g. LRX24-3).
The P-Code programs the actuator for the desired Control Input, Feedback and Running Time.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

11-29
AKR and AFR Series Fail-Safe Actuators
Custom, Fail-Safe Actuators, 180 in-lbs Minimum Torque

Actuator Specifications
Torque 180 in-lbs [20 Nm]
Ambient Temperature -22°F to +122°F
[-30°C to +50°C]
Angle of Rotation max 90°, adjustable with
mechanical stop electronically
variable
Position Indication handle
Manual Override external push-button
Direction of Rotation reversible with switch
Dimensions
Electrical Connection 18 GA plenum rated cable, ½”
conduit connector
Overload Protection electronic throughout rotation
Housing NEMA 2/IP54
Agency Listings cULus acc. to UL 60730-1A/- NEW
2-14, CAN/CSA E60730-1:02,
CSA C22.2 No. 24-93, CE acc.
to 2006/95/EC and 89/336/EEC
CCV

ELECTRONIC FAIL-SAFE NEW

Power Running Cable List


Model Control Input Feedback VA Rating Re-order Number
Supply Time(s) Length Price

AKRB24-IP 2-10 VDC (4-20mA*) Various 24 VAC/DC 150 3 ft. N/A** $998
See page 11-8 for actuator customizing and available P-Codes.
** Re-order numbers only available for customizable “X” version actuators (e.g. LRX24-3).
The P-Code programs the actuator for the desired Control Input, Feedback and Running Time.

SPRING RETURN NEW

Power Running Cable List


Model Control Input Feedback VA Rating Re-order Number
Supply Time(s) Length Price

AFRB24-IP 2-10 VDC (4-20mA*) Various 24 VAC/DC 150 3 ft. N/A** $925
See page 11-8 for actuator customizing and available P-Codes.

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


** Re-order numbers only available for customizable “X” version actuators (e.g. LRX24-3).
The P-Code programs the actuator for the desired Control Input, Feedback and Running Time.

All prices are in US Dollars (USD)

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

11-30
12
HIGH TEMPERATURE
CHARACTERIZED CONTROL
VALVES (HTCCV)
Efficiency for Low Pressure Steam
• Characterizing disc reduces turbulent flow
and improves system efficiency.
• Maintenance free with self-cleaning ball
valve; no repacking required.
• Zero leakage prevents circulation losses and
reduces energy waste.

Michaela DeMarchi, Manager, Training Solutions


High Temperature Characterized Control Valve Nomenclature

B2 15 HT 186 +TR 24 -SR


Valve Valve Size High Cv Actuator Type Power Supply Control
Temperature Blank = On/Off -S = Built-in
B2 = 2-way 15 = ½” 1.86 Non Fail-Safe 24 = 24 VAC/DC
Refer to TR Auxiliary
20 = ¾” 120 = 120 VAC* -3 = On/Off, Floating
Table on Switch
25 = 1” Point
Page 12-1 LRB, LRX
Fail-Safe -SR = 2-10 VDC

TFRB, TFRX -MFT = Multi-Function


Technology
LF

“X” models are customizable.


Refer to page 11-8 for
programming and cable options.

*TFR Series has 100 to 240 VAC nominal power supply.

Ordering Example

1 Choose the valve actuator combination.

B215HT186+TR24-SR US NO Tagging (if needed)


3
2 Specify preference or configuration.
Does order
require
Set-Up tagging?

Non Fail-Safe Models Tagging:


NO = Normally Open Valves may be
NC = Normally Closed tagged per customer
specification. ($12.00
Fail-Safe Models per tag)
NO/FO = Normally Open/Fail Open Example:
NO/FC = Normally Open/Fail Closed AHU-1
FCU-2
NC/FO = Normally Closed/Fail Open
NC/FC = Normally Closed/Fail Closed Part number for tagging:
99981-00101
Refers to valve ports A to AB.

4 Complete Ordering Example: B215HT186+TR24-SR US


Configuration: +NO
High Temperature Characterized Control Valve (HTCCV)
Product Range

Valve Nominal Size Type Suitable Actuators


Cv Inches DN [mm] 2-way NPT Non Fail-Safe Fail-Safe
0.29 ½ 15 B215HT029
0.46 ½ 15 B215HT046
0.73 ½ 15 B215HT073

TFR Series
TR Series
1.16 ½ 15 B215HT116 HT
HTCCV
1.86 ½ 15 B215HT186
Equal Percentage
2.90 ½ 15 B215HT290 Characteristic

4.55 ½ 15 B215HT455
1.86 ¾ 20 B220HT186
Mode of Operation

LR Series
2.90 ¾ 20 B220HT290 The control valve is operated by an electronic actuator
that responds to a standard voltage for on/off, modulating
4.64 ¾ 20 B220HT464 or 3-point control system. The actuator will then move the
7.31 ¾ 20 B220HT731 ball of the valve to the position dictated by the control
signal or voltage and change the flow.
9.28 ¾ 20 B220HT928

LF Series
Product Features
13.20 ¾ 20 B220HT1320 Equal-percentage flow characteristic.
4.64 1 25 B225HT464
7.31 1 25 B225HT731 Actuator Specifications
Control type on/off, floating point, 2-10 VDC
11.60 1 25 B225HT1160 multi-function technology (MFT)
18.56 1 25 B225HT1856 Manual override only TR, LR series
Electrical connection 3 ft. [1 m] cable with ½”conduit
28.00 1 25 B225HT2800 fitting or covered screw
terminal strip
Valve Specifications
Service hot water, up to 60% glycol,
steam
Flow characteristic A-port equal percentage
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

Controllable flow range 75°


Sizes ½”, ¾”, 1”
End fitting NPT female
Materials
Body brass (DZR) P-CuZn35Pb2
All prices are in US Dollars (USD)

Ball stainless steel


Stem stainless steel
Seat ETFE
Stem packing Viton®
Characterizing disc ETFE
Seat o-rings EPDM
Body pressure rating 600 psi
Media temperature range
Steam 250°F [120°C]
Water 60°F to 266°F [16°C to 130°C]
Close-off pressure 200 psi
Maximum differential
pressure (∆P)
Steam 15 psi
Water 60 psi partially open ball
116 psi full open only
(Model #B215HT455)
Maximum inlet pressure
Steam 15 psi
Leakage 0%

12-1
High Temperature Characterized Control Valves

SET-UP - Specify Upon Ordering

2-WAY VALVE

TR24-3 US Power to pin 2 will drive valve CCW.


Power to pin 3 will drive valve CW.
Stays in Last Position
NON FAIL-SAFE

TR24-SR US NC: Closed A to AB, will open as voltage increases. NO: Open A to AB, will close as voltage increases
(Can be chosen with switch inside terminal
block of actuator).

LRB24-3, Power to pin 2 will drive valve CW. Power to pin 3 will NO: Open A to AB, will close as power is applied.
LRX... drive valve CCW. The above will function when the directional
switch is in the ”1” position, to reverse select
the ”0” position.

TFRB24 NO/FO Valve: Open A to AB will drive closed. NC/FC Valve: Closed A to AB will drive open.
LF24 US Spring Action: Will spring open A to AB upon power loss. Spring Action: Will spring closed A to AB upon power loss.
Note Fail Position
FAIL-SAFE

TFRB (-3), -MFT, -SR NC/FO Valve: Closed A to AB will drive open or increase in voltage. NC/FC Valve: Closed A to AB or Open A to AB.
LF (-3), -MFT, -SR Spring Action: Will spring open A to AB upon power loss. Spring Action: Will spring closed A to AB upon power loss.
Floating or Modulating
HTCCV

type actuators
NO/FO Valve: Open A to AB will drive closed or increase in voltage. NO/FC Valve: Open A to AB.
Spring Action: Will spring open A to AB upon power loss. Spring Action: Will spring closed A to AB upon power loss.

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


All prices are in US Dollars (USD)

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

12-2
High Temperature Characterized Control Valves
General Information/Typical Installation

FLOW PATTERN

2-way High Temperature Characterized Control Valves Flow direction

Upstream A
Downstream AB

Valve should be installed with the disc downstream unlike the CCV.

PIPING DIAGRAMS

2-way Valve Piping Diagram 2-way Valve Piping Diagram


Steam (1 Input, 1 Output) Water (1 Input, 1 Output)

HTCCV
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

PIPING/MOUNTING ORIENTATION & INSULATION


Assembly can be mounted horizontally or vertically for water
applications. For steam applications the valve cannot be mounted
vertically. When mounted horizontally, the valve must be 0° to 45° off
center of the pipe. Do not install with actuator below pipe.
All prices are in US Dollars (USD)

0° to 45° 0° to 90°

Steam Applications WaterApplications


Applications
Steam Applications Water

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

12-3
High Temperature Characterized Control Valves with Non Fail-Safe Actuators
2-way Valve with Stainless Steel Ball and Stem, NPT Female Ends

Valve Specifications
Service hot water, up to 60% glycol, steam
Flow Characteristic A-port equal percentage
Controllable Flow Range 75°
End Fitting NPT female
Body brass (DZR) P-CuZn35Pb2 Visit www.belimo.us for additional non fail-safe actuator options.
Ball stainless steel
Stem stainless steel
Seat ETFE
Stem packing Viton
Characterized Disc ETFE
O-ring EPDM
Media Temperature Range
250°F [120°C]
(Steam)
Media Temperature Range
60°F to 266°F [16°C to 130°C]
(Water)
Max Differential Pressure 60 psi partially open ball,
(Water) 116 psi full open (#B215HT455)
Max Inlet Pressure
15 psi
(Steam)
Leakage 0%

ACTUATOR PART # TR24-3 US TR24-SR US LRB24-3 LRB24-SR LRX24-MFT


Control On/Off, Floating Point Modulating On/Off, Floating Point Modulating Modulating/MFT

Running Time (Motor) 90 seconds 90 seconds 90 seconds 90 seconds 150 seconds (variable)
HTCCV

3 ft, 18 GA 3 ft, 18 GA 3 ft, 18 GA plenum cable 3 ft, 18 GA plenum cable 3 ft, 18 GA plenum cable
Electrical Connection
plenum cable plenum cable with ½” conduit connector with ½” conduit connector with ½” conduit connector
2-Way
Body Close-Off
Size
Model # Cv Pressure Pressure
[mm]
Rating [psi] [psi]
B215HT029 0.29 200 $344 $493 $396 $517 $699
B215HT046 0.46 200 $344 $493 $396 $517 $699
B215HT073 0.73 200 $344 $493 $396 $517 $699
½”
B215HT116 1.16 200 $352 $500 $398 $520 $701
[15]
B215HT186 1.86 200 $352 $500 $401 $522 $703
B215HT290 2.9 200 $354 $503 $405 $525 $708

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


B215HT455 4.55 200 $359 $507 $449 $570 $752
B220HT186 1.86 200 $449 $570 $752
B220HT290 2.9 200 $449 $570 $752
600
B220HT464 4.64 ¾” 200 $451 $572 $754
B220HT731 7.31 [20] 200 $451 $572 $754

All prices are in US Dollars (USD)


B220HT928 9.28 200 $453 $574 $757
B220HT1320 13.2 200 $460 $579 $762
B225HT464 4.64 200 $506 $626 $809
B225HT731 7.31 200 $506 $626 $809
1”
B225HT1160 11.6 200 $511 $633 $814
[25]
B225HT1856 18.56 200 $511 $633 $814
B225HT2800 28 200 $517 $637 $821

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

12-4
High Temperature Characterized Control Valves with Fail-Safe Actuators
2-way Valve with Stainless Steel Ball and Stem, NPT Female Ends

Valve Specifications
Service hot water, up to 60% glycol, steam
Flow Characteristic A-port equal percentage
Controllable Flow Range 75°
End Fitting NPT female
Body brass (DZR) P-CuZn35Pb2 Visit www.belimo.us for additional fail-safe actuator options.
Ball stainless steel
Stem stainless steel
Seat ETFE
Stem packing Viton
Characterized Disc ETFE
O-ring EPDM
Media Temperature Range
250°F [120°C]
(Steam)
Media Temperature Range
60°F to 266°F [16°C to 130°C]
(Water)
Max Differential Pressure 60 psi partially open ball,
(Water) 116 psi full open (#B215HT455)
Max Inlet Pressure
15 psi
(Steam)
Leakage 0%

ACTUATOR PART # TFRB24 TFRB24-3 TFRB24-SR TFRX24-MFT LF24 US LF24-SR US LF24-MFT US

Control On/Off Floating Point Modulating Modulating/MFT On/Off Modulating Modulating/MFT


150 seconds 150 seconds
Running Time (Motor) <75 seconds 95 seconds 95 seconds 75 seconds 150 seconds
(variable) (variable)

HTCCV
Running Time (Fail-Safe) < 75 seconds <25 seconds <25 seconds <25 seconds <25 seconds <25 seconds <25 seconds
3 ft, 18 GA 3 ft, 18 GA 3 ft, 18 GA 3 ft, 18 GA 3 ft, 18 GA 3 ft, 18 GA 3 ft, 18 GA
appliance cable plenum cable plenum cable plenum cable appliance cable, plenum cable appliance cable
Electrical Connection
with ½” conduit with ½” conduit with ½” conduit with ½” conduit ½” conduit with ½” conduit with ½” conduit
connector connector connector connector connector connector connector
2-Way
Body Close-Off
Size
Model # Cv Pressure Pressure
[mm]
Rating [psi] [psi]
B215HT029 0.29 200 $499 $589 $639 $723
B215HT046 0.46 200 $499 $589 $639 $723
B215HT073 0.73 200 $499 $589 $639 $723
½”
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

B215HT116 1.16 200 $501 $592 $641 $726


[15]
B215HT186 1.86 200 $501 $592 $641 $726
B215HT290 2.9 200 $511 $603 $651 $736
B215HT455 4.55 200 $517 $607 $656 $740
B220HT186 1.86 200 $604 $776 $947
All prices are in US Dollars (USD)

B220HT290 2.9 200 $604 $776 $947


600
B220HT464 4.64 ¾” 200 $604 $776 $947
B220HT731 7.31 [20] 200 $606 $778 $950
B220HT928 9.28 200 $612 $785 $956
B220HT1320 13.2 200 $616 $789 $960
B225HT464 4.64 200 $698 $871 $1,042
B225HT731 7.31 200 $698 $871 $1,042
1”
B225HT1160 11.6 200 $703 $877 $1,049
[25]
B225HT1856 18.56 200 $710 $881 $1,053
B225HT2800 28 200 $720 $892 $1,064

Note: Weather shields are not available at this time.


Note: 120 V and -S models have appliance cables.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

12-5
Easy Access,
Adjustments, and
Diagnostics

Belimo PC-Tool or ZTH Handheld Device


Multi-Function Technology actuators from Belimo allow you to create custom solutions for individual applications. The Belimo PC-Tool
is a universal software application for setting, commissioning, monitoring and evaluating communications with Multi-Function Technology
actuators. Service related diagnostics are extremely easy and setpoints can be specified and actual values monitored. The trend recording
function can output the information to graphical format for system documentation.

The ZTH handheld device also directly connects to MFT actuators allowing you to quickly change the parameters of the actuator, such
as control input, control feedback, runtime, and minimum and maximum values without needing to connect to a personal computer.

Belimo PC-Tool and the ZTH device are practical solutions for controls distributors and installation contractors.

Download the Belimo PC-Tool


www.belimo.us
13
INDUSTRIAL BALL VALVES
Achieve Control and Reliability
• Bronze, brass, and stainless steel ball valves
with NPT connection for low and medium
pressure steam applications.
• Range of media temperature ratings suited
for chilled, hot water and steam service.
• Fitted with rotary actuators offers easy field
assembly and installation.

Tim Keiser, Group Leader, Customization


Industrial Ball Valve Nomenclature
B2 19 VS +NMX 24 -MFT-X1
Valve Valve Size Industrial Actuator Type Power Supply Control
B2 = 2-way 15-50 = ½” to 2” Construction/ Non Fail-Safe 24 = 24 VAC/DC -3-X1 = -S = Built-in
B3 = 3-way Material LMB, LMX 120 = 120 VAC On/Off, Floating Point Auxiliary
NMB, NMX 230 = 230 VAC -MFT-X1 =Multi-Function Switch
VS = Bronze Body,
Stainless Steel Ball AMB, AMX UP = 24-240 VAC Technology
and Stem GMB, GMX or -MFT95-X1 = 0-135 Ω
VSS = Stainless Steel NRB, NRX 24-125 VDC
Body, Ball and Stem ARB, ARX
L = Nickel Plated LRB, LRX
Brass Body, Chrome GRCX
Plated Brass Ball and PRB, PRX
Stem
Fail-Safe
Spring Return
LF
NFB, NFX
AFB, AFX
Electronic
GKB, GKX

“X” models are customizable.


Refer to page 13-5 for programming options.

Ordering Example

3 For MFT orders only - select programming code


1 Choose the valve actuator combination.

B219VS+NMX24-MFT-X1 NO Tagging (if needed)


4
2 Specify preference or configuration.
Does order
require
Set-Up tagging?

Non Fail-Safe Models


P-10001 (A01) Tagging:
NO = Normally Open Valves may be tagged per
P-100xx (Axx) Control voltage applications customer specification.
NC = Normally Closed
P-200xx (Wxx) Pulse width modulation ($12.00 per tag)
Fail-Safe Models applications
NO/FO = Normally Open/Fail Open P-300xx (Fxx) Floating point applications Example:
NO/FC = Normally Open/Fail Closed AHU-1
P-400xx (Jxx) On/off applications
FCU-2
X-XXXXX Create custom MFT
NC/FO = Normally Closed/Fail Open
configuration code Part number for tagging:
NC/FC = Normally Closed/Fail Closed
X-XXXXX Create custom MFT 99981-00101
Refers to valve ports A to AB. configuration in the field
with MFT actuator PC-Tool software

5 Complete Ordering Example: B219VS+NMX24-MFT-X1


Configuration:
+NO
Programming: +A01
Industrial Ball Valve Product Range

Valve Nominal Size Type Suitable Actuators


3-way
Cv Inches DN [mm] 2-way NPT Non Fail-Safe Fail-Safe
NPT
1 ½ 15 B2050VS-01*

LM Series

LF Series
2 ½ 15 B2050VS-02*
4 ½ 15 B2050VS-04*
15 ½ 15 B2050VS-15*

GR Series
30 ¾ 20 B219VS

Series
NM Series

NF
51 ¾ 20 B220VS
43 1 25 B224VS
Mode of Operation
68 1 25 B225VS

Series
The control valve is operated by an electronic actuator that
AM

AF Series
48 1¼ 32 B232VS responds to a standard voltage for on/off control, by a
modulating VDC/4…20 mA, or 3-point control system. The
84 1½ 40 B239VS actuator will then move the ball of the valve to the position
GM Series

PR Series
dictated by the control signal thus changing the flow.
177 1½ 40 B240VS
Product Features
108 2 50 B249VS
Modified equal percentage of flow for B2. Modified linear flow
for B3.
15 ½ 15 B2050VSS-15*

LF
Series

B3...L valves are for diverting applications and are not rated
GR Series
NM

for steam.
30 ¾ 20 B219VSS

NF
Actuator Specifications
AM

43 1 25 B224VSS AF Series Control type on/off, floating point,


modulating, 2-10 VDC
multi-function technology (MFT)
Series
GM

108 2 50 B249VSS
PR

Manual override LM, NM, GM, AM, GR, PR, AF, NF, GK
Electrical connection 3 ft. [1 m] cable with
6.4 ½ 15 B315L** ½” conduit fitting
LFR Series
LR Series

12.8 ¾ 20 B320L** Valve Specifications


Service chilled or hot water, (60% glycol),
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

11 1 25 B325L** steam (2-way)


Flow characteristic modified equal percentage (B2),
NR

34 1¼ 32 B332L** modified linear (B3...L)


AFR Series

Sizes ½”, ¾”, 1”, 1¼”, 1½”, 2”


57 1½ 40 B340L**
Series

End fitting FNPT


AR
All prices are in US Dollars (USD)

Materials
87 2 50 B350L**
Body bronze (B2..VS)
stainless steel (B2..VSS)
* For hot only or cold only applications. Not for temperature changeover applications. nickel plated brass (B3..L)
** Not for steam applications Ball stainless steel, bronze
(B2050VSS-15)
NOTE: Industrial ball valves (B2..VS, B2..VSS) have serviceable components. Proper maintenance of these chrome plated brass (B3..L)
parts will ensure a longer in-service life for the valves. The seats of these valves will require replacement at Stem stainless steel
an interval consistent with number of full cycles the valve has be operated, or as field condition dictates. nickel plated brass (B3..L)
Seats
2-way MPTFE, RPTFE (B2050)
3-way Teflon PTFE
Stem packing
2-way NPT MPTFE
O-rings NPT EPDM (B3..L)
Media temp range
B2..VS -22°F to +280°F [-30°C to +138°C]
B2..VSS -22°F to +298°F [-30°C to +148°C]
B3...L 0°F to 250°F [-18°C to +120°C]
Body pressure rating
3-way 600 psi DN 15-25 (B3..L ½”-1”)
400 psi DN 32-50 (B3..L 1¼” - 2”)
Maximum inlet pressure
Steam 35 psi B2..VS
50 psi B2..VSS
Leakage ANSI Class VI (B2..VS, VSS)
0% (B3..L)

13-1
Industrial Ball Valves
General Information/Typical Installation

FLOW PATTERN
B2...VS/VSS B3...L

Open CCW

A AB B to A B to AB
Flow Direction Closed CW Open CW Open CCW

NOTE: B3…L are piped differently than B3 CCV Valves.

PIPING DIAGRAMS

2-way Valve Piping Diagram B3...L Diverting & Changeover


Water (Switching) Valve Piping Diagram

2-way Valve Piping Diagram


Steam
VS, VSS BALL VALVES

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


NOTE:
To avoid torque increase during off season shut down or other periods of inactivity longer than 1 month, the valve should be exercised (actuator or manually driven full
open-closed cycle) at least once per month. This is necessary to avoid any application problems after an off season shut down. This is not required for B3...L valves.

All prices are in US Dollars (USD)


PIPING/MOUNTING ORIENTATION
Assembly can be mounted horizontally or vertically for water applications. For steam applications the valve cannot be mounted vertically. When mounted
horizontally, the valve must be 0° to 45° off center of the pipe. Do not install with actuator below pipe.

0° to 90°

0° to 45°

Water Applications Steam Applications

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

13-2
Industrial Ball Valves
General Information/Set-Up

SET-UP - Specify Upon Ordering

2-WAY VALVE 3-WAY VALVE

LMB24-3-X1, NMB24-3-X1, Power to pin 2 will drive Power to pin 2 will drive
AMB24-3-X1, GMB24-3-X1, valve CW. Power to pin 3 valve CW. Power to pin 3
Stays in Last Position

LRB24-3, NRB24-3, ARB24-3, will drive valve CCW. The will drive valve CCW. The
NON FAIL-SAFE

GRB24-3 above will fuction when above will fuction when


the directional switch is in the directional switch is in
the ”1” position to reverse, the ”1” position to reverse,
select the ”0” position. select the ”0” position.

LMX24-MFT-X1, NMX24-MFT-X1,
NC: Normally closed A NO: Normally open A to NC: Normally open B to A, NO: Normally open B to
AMX24-MFT-X1, GMX24-MFT-X1,
to AB, valve will open as AB, valve will close as valve will open as voltage AB, valve will close as
LRX24-MFT, NRX24-MFT,
voltage increases voltage increases increases voltage increases
ARX24-MFT, GRX24-MFT

LF24 US, LF120 US, NFB24-X1, NO/FO: Normally open NC/FC: Normally closed NO/FO: Normally open NC/FC: Normally closed
AFB24-X1, AFBUP-X1, AFRBUP A to AB, valve will drive A to AB, valve will drive B to AB, valve will drive B to AB, valve will drive
closed. open. closed. open.
Spring Action: Actuator Spring Action: Actuator will Spring Action: Actuator Spring Action: Actuator will
Note Fail Position

will fail open A to AB upon fail closed A to AB upon will fail open B to AB upon fail closed B to AB upon
FAIL-SAFE

power loss. power loss. power loss. power loss.

LF24-MFT US, NFX24-MFT-X1, NC/FO: Normally closed A NC/FC: Normally closed A NO/FC: Normally open B NO/FO: Normally open B
AFX24-MFT-X1, AFRX24-MFT to AB, valve will open as to AB, valve will open as to AB, valve will close as to AB, valve will close as
voltage increases. Actuator voltage increases. Actuator voltage increases. Actuator voltage increases. Actuator
switch on CW. switch on CW. switch on CCW. switch on CCW.
Spring Action: Will fail Spring Action: Will fail Spring Action: Will fail Spring Action: Will fail
open upon power loss. closed upon power loss. closed upon power loss. open upon power loss.

VS, VSS BALL VALVES


U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.
All prices are in US Dollars (USD)

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

13-3
Industrial Ball Valves
Piping Reduction Chart

LINE SIZE
¾” 1” 1¼” 1½” 2” 2½” 3” 4”
VALVE SIZE Cv TYPE MODEL #
Fp Cv Fp Cv Fp Cv Fp Cv Fp Cv Fp Cv Fp Cv Fp Cv
½” 1 2W NPT B2050VS-01 1.0 1.0 - - - - - -
½” 2 2W NPT B2050VS-02 2.0 1.9 - - - - - -
½” 4 2W NPT B2050VS-04 3.8 3.6 - - - - - -
½” 15 2W NPT B2050VS-15 8.9 7.2 - - - - - -
¾” 30 2W NPT B219VS/VSS 30.0 21.6 17.4 15.6 - - - -
¾” 51 2W NPT B220VS 51.0 26.5 19.9 17.3 - - - -
1” 43 2W NPT B224VS/VSS - 43.0 36.1 30.5 25.8 - - -
1” 68 2W NPT B225VS - 68.0 48.3 36.7 29.2 - - -
1½” 177 2W NPT B240VS - - - 177.0 102.7 77.9 67.3 -
2” 108 2W NPT B249VS/VSS - - - - 108.0 100.4 91.8 83.2
½” 6.4 3W NPT B315L 5.5 5.0 4.8 - - - - -
¾” 12.8 3W NPT B320L 12.8 11.8 11.0 10.5 - - - -
1” 11 3W NPT B325L - 11.0 10.9 10.7 10.4 - - -
1¼” 34 3W NPT B332L - - 34.0 32.8 29.9 28.2 - -
1½” 57 3W NPT B340L - - - 57.0 51.9 47.4 44.9 -
2” 87 3W NPT B350L - - - - 87.0 82.8 77.9 72.3
VS, VSS BALL VALVES

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


All prices are in US Dollars (USD)

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

13-4
Customize Products
Default and MFT Programming Codes

CONTROL
ACTUATOR CONFIGURATION
P-CODE CONTROL INPUT FEEDBACK POSITION RUNNING TIME List Price
TYPE DESCRIPTION
-MFT P-10001* A01* 2-10 VDC 2-10 VDC 150 seconds No Charge
P-10002 A02 0.5-10 VDC 0-10 VDC 150 seconds No Charge
P-10003 A03 2-10 VDC 0-5.0 VDC 150 seconds No Charge
P-10004 A04 4-7 VDC 2-10 VDC 150 seconds $37
P-10005 A05 6-9 VDC 2-10 VDC 150 seconds $37
P-10006 A06 10.5 -13.5 VDC 2-10 VDC 150 seconds $37
P-10007 A07 0.5-5 VDC 2-10 VDC 150 seconds $37
P-10009 A09 5-10 VDC 2-10 VDC 150 seconds $37
P-10010 A10 5-10 VDC 0-10 VDC 150 seconds $37
P-10013 A13 0.5-10 VDC 2-10 VDC 150 seconds $37
P-10015 A15 2-5 VDC 2-10 VDC 150 seconds $37
P-10016 A16 2-6 VDC 2-10 VDC 150 seconds $37
P-10017 A17 6-10 VDC 2-10 VDC 150 seconds $37
P-10018 A18 14-17 VDC 2-10 VDC 150 seconds $37
P-10019 A19 2-10 VDC 2-10 VDC 100 seconds No Charge
P-10020 A20 9-12 VDC 2-10 VDC 150 seconds $37
P-10028 A28 0.5-10 VDC 0.5-10 VDC 100 seconds No Charge
P-10031 A31 0.5- 4 VDC 2-10 VDC 150 seconds $37
P-10063 A63 0.5-4.5 VDC 0.5- 4.5 VDC 150 seconds No Charge
P-10032 A32 6-14 VDC 2-10 VDC 150 seconds $37
P-10064 A64 5.5-10 VDC 5.5-10.0 VDC 150 seconds No Charge
P-20001 W01 0.59-2.93 seconds PWM 2-10 VDC 150 seconds $37

VS, VSS BALL VALVES


P-20002 W02 0.02 to 5.00 seconds PWM 2-10 VDC 150 seconds No Charge
P-20003 W03 0.10 to 25.50 seconds PWM 2-10 VDC 150 seconds No Charge
P-20004 W04 0.10 to 25.60 seconds PWM 2-10 VDC 150 seconds $37
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

P-20005 W05 0.10 to 5.20 seconds PWM 0-5.0 VDC 150 seconds $37
P-30001 F01 Floating Point 2-10 VDC 150 seconds No Charge
P-30002 F02 Floating Point 0-10 VDC 150 seconds $37
All prices are in US Dollars (USD)

P-40002 J02 On/Off 2-10 VDC 150 seconds No Charge


* Default configuration

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

13-5
B2…VS Series Ball Valves with Non Fail-Safe Actuators
2-way Valve, Bronze Body, NPT Female Ends

Valve Specifications
chilled or hot water, up to 60%
Service
glycol, 35 lbs. steam
Flow Characteristic modified equal percentage
90° rotation, valve open CCW,
Controllable Flow Range
valve closed CW
End Fitting FNPT
Body B584-C84400 bronze
Ball 316 stainless steel
Seat MPTFE, RPTFE (B2050)
Stem 316 stainless steel
Bearing PEEK/PTFE, RPTFE (B2050)
Stem Packing MPTFE
Body Seal PTFE
Retainer B16 brass
Gland B16 brass
Jam Nut stainless steel
Media Temperature Range -22°F to +280°F
(Water) [-30°C to +138°C]
Maximum Velocity 15 FPS
Leakage ANSI Class VI

ACTUATOR PART # LMB24-3-X1 NMB24-3-X1 AMB24-3-X1 GMB24-3-X1


Control On/Off, Floating Point On/Off, Floating Point On/Off, Floating Point On/Off, Floating Point
Manual Override • • • •
Running Time (Motor) 90 seconds 90 seconds 90 seconds 150 seconds
3 ft, 18 GA appliance rated cable 3 ft, 18 GA plenum rated cable 3 ft, 18 GA plenum rated cable 3 ft, 18 GA appliance rated cable
Electrical Connection
with ½” conduit connector with ½” conduit connector with ½” conduit connector with ½” conduit connector
2-Way
Body Close-Off
Size
Model # Cv Pressure Pressure
[mm]
Rating [psi] [psi]
B2050VS-01 1 100 $733
B2050VS-02 2 100 $733
½” [15]
B2050VS-04 4 100 $733
VS, VSS BALL VALVES

B2050VS-15 15 100 $733


B219VS 30 400 $943
¾” [20]
B220VS 51 600 psig 400 $973
B224VS 43 WOG 400 $1,082
1” [25]

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


B225VS 68 200 $1,211
B232VS 48 1¼” [32] 600 $1,425
B239VS 84 600 $1,711
1½” [40]
B240VS 177 600 $1,764
B249VS 108 2” [50] 600 $1,998

All prices are in US Dollars (USD)

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

13-6
B2…VS Series Ball Valves with Non Fail-Safe Actuators
2-way Valve, Bronze Body, NPT Female Ends

Valve Specifications
chilled or hot water, up to 60%
Service
glycol, 35 lbs. steam
Flow Characteristic modified equal percentage
90° rotation, valve open CCW,
Controllable Flow Range
valve closed CW
End Fitting FNPT
Body B584-C84400 bronze
Ball 316 stainless steel
Seat MPTFE, RPTFE (B2050)
Stem 316 stainless steel
Bearing PEEK/PTFE, RPTFE (B2050)
Stem Packing MPTFE
Body Seal PTFE
Retainer B16 brass
Gland B16 brass
Jam Nut stainless steel
Media Temperature Range
-22°F to +280°F [-30°C to +138°C]
(Water)
Maximum Velocity 15 FPS
Leakage ANSI Class VI

ACTUATOR PART # LMX24-MFT-X1 NMX24-MFT-X1 AMX24-MFT-X1 GMX24-MFT-X1


Control Modulating/MFT Modulating/MFT Modulating/MFT Modulating/MFT
Manual Override • • • •
Running Time (Motor) 150 seconds (variable) 150 seconds (variable) 150 seconds (variable) 150 seconds (variable)
3 ft, 18 GA plenum rated cable 3 ft, 18 GA plenum rated cable 3 ft, 18 GA plenum rated cable 3 ft, 18 GA plenum rated cable
Electrical Connection
with ½” conduit connector with ½” conduit connector with ½” conduit connector with ½” conduit connector
2-Way
Body Close-Off
Size
Model # Cv Pressure Pressure
[mm]
Rating [psi] [psi]
B2050VS-01 1 100 $998
B2050VS-02 2 100 $998
½” [15]
B2050VS-04 4 100 $998

VS, VSS BALL VALVES


B2050VS-15 15 100 $998
B219VS 30 400 $1,369
¾” [20]
B220VS 51 600 psig 400 $1,417
B224VS 43 WOG 400 $1,465
1” [25]
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

B225VS 68 200 $1,595


B232VS 48 1¼” [32] 600 $1,764
B239VS 84 600 $1,782
1½” [40]
B240VS 177 600 $1,952
B249VS 108 2” [50] 600 $2,169
All prices are in US Dollars (USD)

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

13-7
B2…VS Series Ball Valves with Fail-Safe Actuators
2-way Valve, Bronze Body, NPT Female Ends

Valve Specifications
chilled or hot water, up to 60%
Service
glycol, 35 lbs. steam
Flow Characteristic modified equal percentage
90° rotation, valve open CCW,
Controllable Flow Range
valve closed CW
Visit www.belimo.us for additional fail-safe options.
End Fitting FNPT
Body B584-C84400 bronze
Ball 316 stainless steel
Seat MPTFE, RPTFE (B2050)
Stem 316 stainless steel
Bearing PEEK/PTFE, RPTFE (B2050)
Stem Packing MPTFE
Body Seal PTFE
Retainer B16 brass
Gland B16 brass
Jam Nut stainless steel
Media Temperature Range
-22°F to +280°F [-30°C to +138°C]
(Water)
Maximum Velocity 15 FPS
Leakage ANSI Class VI

ACTUATOR PART # LF24 US LF120 US LF24-MFT US NFB24-X1 NFBUP-X1 NFX24-MFT-X1


Control On/Off On/Off Modulating/MFT On/Off On/Off Modulating/MFT
Manual Override • • •
150 seconds 150 seconds
Running Time (Motor) 75 seconds 75 seconds <75 seconds <75 seconds
(variable) (variable)
Running Time (Fail-Safe) <25 seconds <25 seconds <25 seconds 20 seconds <20 seconds < 20 seconds
3 ft, 18 GA appliance 3 ft, 18 GA appliance 3 ft, 18 GA appliance 3 ft, 18 GA appliance 3 ft, 18 GA appliance 3 ft, 18 GA appliance
Electrical Connection cable with ½” conduit cable with ½” conduit cable with ½” conduit cable wtih ½” conduit cable wtih ½” conduit cable wtih ½” conduit
connector connector connector connector connector connector
2-Way
Body Close-Off
Size
Model # Cv Pressure Pressure
[mm]
Rating [psi] [psi]
B2050VS-01 1 100 $791 $841 $1,104
VS, VSS BALL VALVES

B2050VS-02 2 100 $791 $841 $1,104


½” [15]
B2050VS-04 4 600 psig 100 $791 $841 $1,104
B2050VS-15 15 WOG 100 $791 $841 $1,104
B219VS 30 400 $1,075 $1,138 $1,383

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


¾” [20]
B220VS 51 400 $1,125 $1,184 $1,435

All prices are in US Dollars (USD)

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

13-8
B2…VS Series Ball Valves with Fail-Safe Actuators
2-way Valve, Bronze Body, NPT Female Ends

Valve Specifications
chilled or hot water, up to 60%
Service
glycol, 35 lbs. steam
Flow Characteristic modified equal percentage
90° rotation, valve open CCW,
Controllable Flow Range
valve closed CW Visit www.belimo.us for additional fail-safe options.
End Fitting FNPT
Body B584-C84400 bronze
Ball 316 stainless steel
Seat MPTFE, RPTFE (B2050)
Stem 316 stainless steel
Bearing PEEK/PTFE
Stem Packing MPTFE
Body Seal PTFE
Retainer B16 brass
Gland B16 brass
Jam Nut stainless steel
Media Temperature Range -22°F to +280°F
(Water) [-30°C to +138°C]
Maximum Velocity 15 FPS
Leakage ANSI Class VI

ACTUATOR PART # AFB24-X1 AFBUP-X1 AFX24-MFT-X1 2*AFX24-MFT-X1


Control On/Off On/Off Modulating/MFT Modulating/MFT
Manual Override • • • •
Running Time (Motor) <75 seconds <75 seconds 150 seconds (variable) 150 seconds (variable)
Running Time (Fail-Safe) 20 seconds 20 seconds <20 seconds 20 seconds

3 ft, 18 GA appliance cable with 3 ft, 18 GA appliance cable with 3 ft, 18 GA appliance cable with 3 ft, 18 GA appliance cable with
Electrical Connection
½” conduit connector ½” conduit connector ½” conduit connector ½” conduit connector

2-Way
Body Close-Off
Size
Model # Cv Pressure Pressure
[mm]
Rating [psi] [psi]
B224VS 43 600 $1,213 $1,296 $1,512
1” [25]

VS, VSS BALL VALVES


B225VS 68 200 $1,449 $1,531 $1,670
B232VS 48 1¼” [32] 600 psig 600 $1,533 $1,615 $1,766
B239VS 84 WOG 600 $2,688
1½” [40]
B240VS 177 600 $2,707
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

B249VS 108 2” [50] 600 $3,033

1½” and 2” use tandem mounted actuators


All prices are in US Dollars (USD)

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

13-9
B3…L Series Ball Valves with Non Fail-Safe Actuators
3-way Valve, Nickel Plated Brass Body, NPT Female Ends

Valve Specifications
chilled , hot water, up to 60%
Service
glycol
Flow Characteristic modified linear
End Fitting FNPT
Body forged brass, nickel plated
Ball chrome plated brass
Stem nickel plated brass
Seat Teflon PTFE
Media Temperature Range
0°F to 250°F [-18°C to +120°C]
(Water)
Max Differential Pressure
50 psi
(Water)
Leakage 0%

ACTUATOR PART # LRB24-3 LRX24-MFT NRX24-3 NRX24-MFT ARB24-3 ARX24-MFT


Control On/Off, Floating Point Modulating/MFT On/Off, Floating Point Modulating/MFT On/Off, Floating Point Modulating/MFT
Manual Override • • • • • •
150 seconds 150 seconds 150 seconds
Running Time (Motor) 90 seconds 90 seconds 90 seconds
(variable) (variable) (variable)

3 ft, 18 GA 3 ft, 18 GA
3 ft, 18 GA plenum 3 ft, 18 GA plenum 3 ft, 18 GA plenum 3 ft, 18 GA plenum
applicance rated applicance rated
Electrical Connection cable with ½” conduit cable with ½” conduit cable with ½” conduit cable with ½” conduit
cable with ½” conduit cable with ½” conduit
connector connector connector connector
connector connector

3-Way Diverting
Body Close-Off
Size
Model # Cv Pressure Pressure
[mm]
Rating [psi] [psi]
VS, VSS BALL VALVES

B315L 6.4 ½” [15] 200 $583 $897


B320L 12.8 ¾” [20] 600 200 $616 $930
B325L 11 1” [25] 200 $712 $1,026
B332L 34 1¼” [32] 200 $928 $1,229

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


B340L 57 1½” [40] 400 200 $1,483 $1,802
B350L 87 2” [50] 200 $1,889 $2,208
B3...L Ball Valves are not for steam applications.

All prices are in US Dollars (USD)

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

13-10
B3…L Series Ball Valves with Fail-Safe Actuators
3-way Valve, Nickel Plated Brass Body, NPT Female Ends

Valve Specifications
chilled , hot water, up to 60%
Service
glycol
Flow Characteristic modified linear
End Fitting FNPT
Body forged brass, nickel plated Visit www.belimo.us to see additional fail-safe options.
Ball chrome plated brass
Stem nickel plated brass
Seat Teflon PTFE
Media Temperature Range
0°F to 250°F [-18°C to +120°C]
(Water)
Max Differential Pressure
50 psi
(Water)
Leakage 0%

ACTUATOR PART # LF24-3 US LF24-MFT US AFRBUP AFRX24-MFT


Control On/Off, Floating Point Modulating/MFT On/Off Modulating/MFT
Manual Override • •
Running Time (Motor) 75 seconds 150 seconds (variable) 75 seconds 150 seconds (variable)
Running Time (Fail-Safe) <25 seconds <25 seconds < 20 seconds < 20 seconds

3 ft, 18 GA plenum cable with 3 ft, 18 GA appliance cable with 3 ft, 18 GA appliance cable with 3 ft, 18 GA appliance cable with
Electrical Connection
½” conduit connector ½” conduit connector ½” conduit connector ½” conduit connector

3-Way Diverting
Body Close-Off
Size
Model # Cv Pressure Pressure
[mm]
Rating [psi] [psi]
B315L 6.4 ½” [15] 200 $790 $1,013
B320L 12.8 ¾” [20] 600 200 $824 $1,048
B325L 11 1” [25] 200 $917 $1,141

VS, VSS BALL VALVES


B332L 34 1¼” [32] 200 $1,770 $2,231
B340L 57 1½” [40] 400 200 $2,012 $2,472
B350L 87 2” [50] 200 $2,418 $2,877
B3...L Ball Valves are not for steam applications.
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.
All prices are in US Dollars (USD)

ACTUATOR PART # AFRXUP N4 AFRX24-MFT N4


Control On/Off Modulating/MFT
Manual Override • •
Running Time (Motor) 75 seconds 150 seconds (variable)
Running Time (Fail-Safe) < 20 seconds < 20 seconds

Electrical Connection 3 ft, 18 GA appliance cable with ½” conduit connector 3 ft, 18 GA appliance cable with ½” conduit connector

3-Way Diverting
Body Close-Off
Size
Model # Cv Pressure Pressure
[mm]
Rating [psi] [psi]
B350L 87 2” [50] 400 200 $2,808 $3,355


Heater option for NEMA 4X products has a list price adder of $500.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

13-11
B2…VS Series Ball Valves with NEMA 4X Non Fail-Safe Actuators
2-way Valve, Bronze Body, NPT Female Ends

Valve Specifications
chilled or hot water, up to 60%
Service
glycol, 35 lbs. steam
Flow Characteristic modified equal percentage
90° rotation, valve open CCW,
Controllable Flow Range
valve closed CW
End Fitting FNPT
Body B584-C84400 bronze
Ball 316 stainless steel
Seat MPTFE, RPTFE (B2050)
Stem 316 stainless steel
Bearing PEEK/PTFE, RPTFE (B2050)
Stem Packing MPTFE
Body Seal PTFE
Retainer B16 brass
Gland B16 brass
Jam Nut stainless steel
Media Temperature Range
-22°F to +280°F [-30°C to +138°C]
(Water)
Maximum Velocity 15 FPS
Leakage ANSI Class VI

GRCX24-MFT-T GRCX120-SR-T
ACTUATOR PART # GRCX24-3-T N4 GRCX120-3 N4 PRBUP-3-T PRXUP-MFT-T*
N4 N4
Control On/Off, Floating Point Modulating/MFT On/Off, Floating Point Modulating On/Off, Floating Point Modulating/MFT
Manual Override • • • • • •
35 seconds (default), 35 seconds (default),
Running Time (Motor) 35 seconds 35 seconds 35 seconds 35 seconds 30-120 field 30-120 field
adjustable adjustable

3 ft, 18 GA plenum
Electrical Connection terminal block terminal block cable with ½” conduit terminal block terminal block terminal block
connector
2-Way
Body Close-Off
Size
Model # Cv Pressure Pressure
[mm]
Rating [psi] [psi]
VS, VSS BALL VALVES

B2050VS-01 1 600 $1,548 $1,625 $1,649 $1,732


B2050VS-02 2 600 $1,548 $1,625 $1,649 $1,732
½” [15]
B2050VS-04 4 600 $1,548 $1,625 $1,649 $1,732
B2050VS-15 15 600 $1,548 $1,625 $1,649 $1,732

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


B219VS 30 600 $1,716 $1,802 $1,828 $1,920
¾” [20]
B220VS 51 600 psig 600 $1,739 $1,826 $1,852 $1,945
B224VS 43 WOG 600 $1,771 $1,860 $1,886 $1,980
1” [25]
B225VS 68 600 $1,788 $1,878 $1,904 $2,000

All prices are in US Dollars (USD)


B232VS 48 1¼” [32] 600 $1,942 $2,039 $2,068 $2,172
B239VS 84 600 $2,011 $2,112 $2,142 $2,249 $3,327 $4,775
1½” [40]
B240VS 177 600 $3,392 $4,839
B249VS 108 2” [50] 600 $3,531 $4,979
*Factory programmed running time 35, 60, 90, 120 seconds available with “X” model, e.g. PRXUP-MFT-T

Heater option for NEMA 4X products has a list price adder of $500.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

13-12
B2…VSS Series Ball Valves with Non Fail-Safe Actuators
2-way Valve, Stainless Steel Body, NPT Female Ends

Valve Specifications
chilled or hot water, up to 60%
Service
glycol, 50 lbs. steam
Flow Characteristic modified equal percentage
90° rotation, valve open CCW,
Controllable Flow Range
valve closed CW
End Fitting FNPT
Body A351-CF8M 316 stainless steel
Ball 316 stainless steel
Seat MPTFE, RPTFE (B2050)
Stem 316 stainless steel
Bearing PEEK/PTFE, RPTFE (B2050)
Stem Packing MPTFE
Body Seal PTFE
Retainer 316 stainless steel
Gland A276-316
Jam Nut stainless steel
Media Temperature Range
-22°F to +298°F [-30°C to +148°C]
(Water)
Maximum Velocity 15 FPS
Leakage ANSI Class VI

LMX24- NMX24- AMX24- GMX24-


ACTUATOR PART # LMB24-3-X1 NMB24-3-X1 AMB24-3-X1 GMB24-3-X1
MFT-X1 MFT-X1 MFT-X1 MFT-X1
On/Off, Modulating/ On/Off, Modulating/ On/Off, Modulating/ On/Off, Modulating/
Control
Floating Point MFT Floating Point MFT Floating Point MFT Floating Point MFT
Manual Override • • • • • • • •
150 seconds 150 seconds 150 seconds 150 seconds
Running Time (Motor) 90 seconds 90 seconds 90 seconds 150 seconds
(variable) (variable) (variable) (variable)

3 ft, 18 GA 3 ft, 18 GA 3 ft, 18 GA 3 ft, 18 GA 3 ft, 18 GA 3 ft, 18 GA 3 ft, 18 GA 3 ft, 18 GA


appliance rated plenum rated plenum rated plenum rated plenum rated plenum rated appliance rated plenum rated
Electrical Connection cable with cable with cable with cable with cable with cable with cable with cable with
½” conduit ½” conduit ½” conduit ½” conduit ½” conduit ½” conduit ½” conduit ½” conduit
connector connector connector connector connector connector connector connector

2-Way

VS, VSS BALL VALVES


Body Close-Off
Size
Model # Cv Pressure Pressure
[mm]
Rating [psi] [psi]
B2050VSS-15 15 ½” [15] 2000 psig WOG 1000 $951 $1,398
B219VSS 30 ¾” [20] 1000 $1,321 $1,764
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

B224VSS 43 1” [25] 1500 psig 1000 $1,487 $1,868


WOG
B249VSS 108 2” [50] 1000 $2,888 $3,095
All prices are in US Dollars (USD)

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

13-13
B2…VSS Series Ball Valves with Fail-Safe Actuators
2-way Valve, Stainless Steel Body, NPT Female Ends

Valve Specifications
chilled or hot water, up to 60%
Service
glycol, 50 lbs. steam
Flow Characteristic modified equal percentage
90° rotation, valve open CCW,
Controllable Flow Range
valve closed CW Visit www.belimo.us for additional fail-safe options.
End Fitting FNPT
Body A351-CF8M 316 stainless steel
Ball 316 stainless steel
Seat MPTFE, RPTFE (B2050)
Stem 316 stainless steel
Bearing PEEK/PTFE, RPTFE (B2050)
Stem Packing MPTFE
Body Seal PTFE
Retainer 316 stainless steel
Gland A276-316
Jam Nut stainless steel
Media Temperature Range
-22°F to +298°F [-30°C to +148°C]
(Water)
Maximum Velocity 15 FPS
Leakage ANSI Class VI

2*AFX24-
ACTUATOR PART # LF24 US LF24-MFT US NFB24-X1 NFX24-MFT-X1 AFB24-X1 AFX24-MFT-X1
MFT-X1
Control On/Off Modulating/MFT On/Off Modulating/MFT On/Off Modulating/MFT Modulating/MFT

Manual Override • • • • •
150 seconds 150 seconds 150 seconds 150 seconds
Running Time (Motor) 75 seconds <75 seconds <75 seconds
(variable) (variable) (variable) (variable)
Running Time (Fail-Safe) <25 seconds <25 seconds 20 seconds < 20 seconds 20 seconds <20 seconds 20 seconds

3 ft, 18 GA 3 ft, 18 GA 3 ft, 18 GA 18 GA applicance 3 ft, 18 GA 18 GA applicance 18 GA applicance


appliance cable appliance cable appliance cable rated cable with appliance cable rated cable with rated cable with
Electrical Connection
with ½” conduit with ½” conduit with ½” conduit ½” conduit with ½” conduit ½” conduit ½” conduit
connector connector connector connector connector connector connector

2-Way
Body Close-Off
VS, VSS BALL VALVES

Size
Model # Cv Pressure Pressure
[mm]
Rating [psi] [psi]
B2050VSS-15 15 ½” [15] 2000 psig WOG 1000 $991 $1,550
B219VSS 30 ¾” [20] 1000 $1,504 $2,032

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


B224VSS 43 1” [25] 1500 psig 1000 $1,617 $2,167
WOG
B249VSS 108 2” [50] 1000 $4,594

2* Designates tandem actuators.

All prices are in US Dollars (USD)

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

13-14
B2…VSS Series Ball Valves with NEMA 4X Non Fail-Safe Actuators
2-way Valve, Stainless Steel Body, NPT Female Ends

Valve Specifications
chilled or hot water, up to 60%
Service
glycol, 50 lbs. steam
Flow Characteristic modified equal percentage
90° rotation, valve open CCW,
Controllable Flow Range
valve closed CW
End Fitting FNPT
Body A351-CF8M 316 stainless steel
Ball 316 stainless steel
Seat MPTFE, RPTFE (B2050)
Stem 316 stainless steel
Bearing PEEK/PTFE, RPTFE (B2050)
Stem Packing MPTFE
Body Seal PTFE
Retainer 316 stainless steel
Gland A276-316
Jam Nut stainless steel
Media Temperature Range
-22°F to +298°F [-30°C to +148°C]
(Water)
Maximum Velocity 15 FPS
Leakage ANSI Class VI

GRCX24-MFT-T
ACTUATOR PART # GRCX24-3-T N4 GRCX120-3 N4 GRCX120-SR-T N4 PRBUP-3-T PRXUP-MFT-T*
N4

Control On/Off, Floating Point Modulating/MFT On/Off, Floating Point Modulating On/Off, Floating Point Modulating/MFT
Manual Override • • • • • •
35 seconds (default), 35 seconds (default),
Running Time (Motor) 35 seconds 35 seconds 35 seconds 35 seconds 30-120 field 30-120 field
adjustable adjustable
3 ft, 18 GA plenum
Electrical Connection terminal block terminal block cable with ½” conduit terminal block terminal block terminal block
connector
2-Way
Body Close-Off
Size
Model # Cv Pressure Pressure
[mm]

VS, VSS BALL VALVES


Rating [psi] [psi]
B2050VSS-15 15 ½” [15] 2000 psig WOG 1000 $1,780 $1,860 $1,896 $1,976
B219VSS 30 ¾” [20] 1000 $2,035 $2,127 $2,168 $2,259
B224VSS 43 1” [25] 1500 psig 1000 $2,136 $2,232 $2,275 $2,371
WOG
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

B249VSS 108 2” [50] 1000 $4,177 $5,625

*Factory programmed running time 35, 60, 90, 120 seconds available with “X” model, e.g. PRXUP-MFT-T

Heater option for NEMA 4X products has a list price adder of $500.
All prices are in US Dollars (USD)

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

13-15
Small Devices,
Big Impact

Efficient in Every Way


Our unique self-cleaning and bubble-tight ball valve technology prevents circulation losses
in hydronic systems, having a major impact on reducing wasted energy.

CESIM. Small Devices, Big Impact.


Comfort | Energy Efficiency | Safety | Installation | Maintenance

Find out more


belimo.us/cesim
14
V BALL CONTROL VALVES
High Performance for
Aggressive Applications
• ANSI Class IV leakage rating preventing
energy loss and reduces operating costs.
• Fluid temperature up to 380°F is
ideal for chilled, hot water or steam service.
• Fitted with rotary actuators for easy field
assembly and installation.

Victor A. Coppola, Vice President,


Product Management & Marketing, Americas
V Ball Control Valve Nomenclature
B2 100 VB -024 +AMX 24 -MFT-X1
Valve Valve Size Industrial Cv Actuator Power Supply Control
B2 = 2-way 12-50 = 1” to 2” Construction/ 24 - 507 Type 24 = 24 VAC/DC -3-X1 = On/Off, -S = Built-in
(1” to 2”) 80-150 = 3” to 6” Material Non Fail-Safe 120 = 120 VAC Floating Point Auxiliary
B6 = 2-way (Flanged) AMB, AMX 230 = 230 VAC -MFT-X1 = Switch
VB = Chrome
Flanged (3” to 6” ) plated stainless GMB, GMX UP = 24-240 VAC Multi-Function
steel V ball or 24-125 VDC Technology
SY
-MFT95-1X =
PRB, PRX
0-135 Ω
Fail-Safe
Spring Return
NFB, NFX
AFB, AFX
EFX
Electronic
GKB, GKX

“X” models are customizable.


Refer to page 13-5 for programming options.

Ordering Example

3 For MFT orders only - select programming code


1 Choose the valve actuator combination.

B2100VB-024+AMX24-MFT-X1 NO Tagging (if needed)


4
2 Specify preference or configuration.
Does order
require
Set-Up tagging?

Non Fail-Safe Models


P-10001 (A01) Tagging:
NO = Normally Open Valves may be tagged per
P-100xx (Axx) Control voltage applications customer specification.
NC = Normally Closed
P-200xx (Wxx) Pulse width modulation ($12.00 per tag)
Fail-Safe Models applications
NO/FO = Normally Open/Fail Open P-300xx (Fxx) Floating Point applications Example:
NO/FC = Normally Open/Fail Closed AHU-1
P-400xx (Jxx) On/Off applications
FCU-2
X-XXXXX Create custom MFT
NC/FO = Normally Closed/Fail Open
configuration code Part number for tagging:
NC/FC = Normally Closed/Fail Closed
X-XXXXX Create custom MFT 99981-00101
Refers to valve ports A to AB. configuration in the field
with MFT-actuator PC-Tool software

5 Complete Ordering Example: B2100VB-024+AMX24-MFT-X1


Configuration:
+NO
Programming: +A01
V Ball Control Valve Product Range

Valve Nominal Size Type


Fail-Safe
DN 2-way Non
Cv Inches 2-way NPT Spring
[mm] Flanged Fail-Safe Electronic
Return

NF Series
024 1 25 B2100VB-024

AM Series
055 1½ 40 B2150VB-055

PR Series
077 2 50 B2200VB-077 Equal Percentage

AF
Characteristic

GK Series
207 3 80 B6300VB-207

GM
350 4 100 B6400VB-350

EF
Mode of Operation
507 6 150 B6600VB-507 The control valve is operated by an electronic actuator
that responds to a standard voltage for on/off control,
by a modulating VDC/4…20 mA, or 3-point control
system. The actuator will then move the ball of the
NOTE: Industrial ball valves have serviceable components. Proper maintenance of these parts will ensure a longer
valve to the position dictated by the control signal thus
in-service life for the valves. The seats of these valves will require replacement at an interval consistent with number
changing the flow.
of full cycles the valve has be operated, or as field condition dictates.
Product Features
Equal percentage of flow
300:1 rangeability
ANSI Leakage Class IV

Actuator Specifications
Control type on/off, floating point,
modulating, 2-10 VDC
multi-function technology (MFT)
Manual override all models
Electrical connection 3 ft. [1 m] cable with
½” conduit fitting, terminal block
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

Valve Specifications
Service chilled or hot water,
(60% glycol), steam
Flow characteristic equal percentage
Sizes 1”, 1½”, 2”, 3”, 4”, 6”
All prices are in US Dollars (USD)

End fitting SAE NPT female (1” to 2”)


ANSI flanged (3” to 6”)
Materials
Body carbon steel
Characterizing ball hardened chrome plated
stainless steel
Stem stainless steel
Seats Teflon®
O-rings ALFAS
Stem packing spring loaded Teflon® V-ring
Bushings Stanyl PA46
Media temp. range 380°F max.
Body pressure rating NPT ANSI 300 (1” to 2”)
Flanged ANSI 150 (3” to 6”)
Maximum ∆P steam 100 psi
Maximum ∆P water 100 psi
Close-off pressure
Water 150 psi
Steam 200 psi
Maximum inlet pressure
Steam 200 psi
Leakage ANSI Class IV

14-1
V Ball Control Valves
General Information / Typical Installation

FLOW PATTERN

A AB

PIPING DIAGRAMS
Water Application Steam Application
2-way Valve Piping Diagram 2-way Valve Piping Diagram

PIPING/MOUNTING ORIENTATION

Assembly can be mounted horizontally or vertically for water applications. For steam applications the valve cannot be mounted vertically. When mounted
horizontally, the valve must be 0° to 45° off center of the pipe. Do not install with actuator below pipe.

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


All prices are in US Dollars (USD)
V BALL VALVES

0° to 90°

0° to 45°

Water Applications Steam Applications

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

14-2
V Ball Control Valves
General Information / Set-Up

SET-UP - Specify Upon Ordering

2-WAY VALVE

AMB24-3-X1, GMB24-3-X1 Power to pin 2 will drive valve CW.


Stays in Last Position

Power to pin 3 will drive valve CCW.


NON FAIL-SAFE

The above will fuction when the


directional switch is in the ”1” position
to reverse, select the ”0” position.

NC: Normally closed A to AB, valve NO: Normally open A to AB, valve will
AMX24-MFT-X1, GMX24-MFT-X1 will open as voltage increases close as voltage increases

AFB24-X1, AFBUP-X1, NO/FO: Normally open A to AB, valve NC/FC: Normally closed A to AB, valve
NFB24-X1 will drive closed. will drive open.
SPRING RETURN
Note Fail Position

Spring Action: Actuator will fail open A Spring Action: Actuator will fail closed
to AB upon power loss. A to AB upon power loss.

NFX24-MFT-X1, AFX24-MFT-X1, NC/FO: Normally closed A to AB, NC/FC: Normally closed A to AB,
EFX24-MFT valve will open as voltage increases. valve will open as voltage increases.
Actuator switch on CW. Actuator switch on CW.
Spring Action: Will fail open upon Spring Action: Will fail closed upon
power loss. power loss.

GKB24-3-X1† Power to pin 4 will drive valve


ELECTRONIC FAIL-SAFE

CW. Power to pin 3 will drive valve


CCW. The above will fuction when
the directional switch is in the ”FO”
position to reverse, select the ”FC”
position.
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

GKX24-MFT-X1† NC: Normally closed A to AB, will NO: Normally open A to AB, will close
open as voltage increases when as voltage increases when directional
directional switch is in the ”FO” switch is in the ”FC” position.
position.
All prices are in US Dollars (USD)

† The GK series Electronic Fail-Safe actuator will drive to a predetermined postion using the FO/FC dial on the actuator upon loss of power.

V BALL VALVES

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

14-3
V Ball Control Valves
Piping Reduction Chart

LINE SIZE
VALVE 1” 1¼” 1½” 2” 2½” 3” 4” 5” 6” 8” 10”
Cv TYPE MODEL #
SIZE Fp Cv Fp Cv Fp Cv Fp Cv Fp Cv Fp Cv Fp Cv Fp Cv Fp Cv Fp Cv Fp Cv
1” 24 2-Way NPT B2100VB-024 24.0 22.6 21.1 19.3 - - - - - - -
1½” 55 2-Way NPT B2150VB-055 - - 55.0 50.4 46.3 43.9 - - - - -
2” 77 2-Way NPT B2200VB-077 - - - 77.0 74.1 70.5 66.2 - - - -
3” 207 2-Way Flanged B6300VB-027 - - - - - 207.0 191.3 177.2 168.9 - -
4” 350 2-Way Flanged B6400VB-350 - - - - - - 350.0 333.0 313.2 290.3 -
6” 507 2-Way Flanged B6600VB-507 - - - - - - - - 507.0 491.5 475.5

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


All prices are in US Dollars (USD)
V BALL VALVES

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

14-4
V Ball Control Valves with Non Fail-Safe Actuators
2-way Valve with Stainless Steel Ball and Stem

Valve Specifications
chilled or hot water, up to 60%
Service
glycol, steam
Flow Characteristic equal percentage
Controllable Flow Range 75°
NPT female (1” to 2”);
End Fitting
ANSI flange (3” to 6”)
Body WCC grade carbon steel
Ball stainless steel
Stem stainless steel
Seat Teflon®
Stem packing spring loaded Teflon® V-ring
Media Temperature Range
-22°F to +380°F [-30°C to +193°C]
(Water)
Media Temperature Range
-22°F to +380°F [-30°C to +193°C]
(Steam)
Max Differential Pressure
150 psi
(Water)
Max Differential Pressure
100 psi
(Steam)
Max Inlet Pressure
200 psi
(Steam)
Leakage ANSI Class IV

ACTUATOR PART # AMB24-3-X1 AMX24-MFT-X1 PRBUP-3-T PRXUP-MFT-T*

On/Off, On/Off,
Control Modulating/MFT Modulating/MFT
Floating Point Floating Point
Manual Override • • • •
35 seconds (default), 135 seconds (default),
Running Time (Motor) 90 seconds 150 seconds (variable)
30-120 field adjustable 30-120 field adjustable

3 ft, 18 GA plenum rated cable 3 ft, 18 GA plenum rated cable


Electrical Connection terminal block terminal block
with ½” conduit connector with ½” conduit connector

2-Way
Body Close-Off
Size
Model # Cv Pressure Pressure
[mm]
Rating [psi] [psi]
B2100VB-024 24 1” [25] 200 $2,884 $3,129 $4,745 $6,193
ASME/ANSI
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

B2150VB-055 55 1½” [40] 200 $3,398 $3,643 $5,317 $6,764


Class 300
B2200VB-077 77 2” [50] 200 $3,594 $3,838 $5,704 $7,151
B6300VB-207 207 3” [80] 200 $5,647 $5,893 $7,667 $9,115
ASME/ANSI
B6400VB-350 350 4” [100] 200 $10,291 $11,739
Class 150
B6600VB-507 507 6” [150] 200 $13,504 $14,952
All prices are in US Dollars (USD)

*Factory programmed running time 35, 60, 90, 120 seconds available with “X” model, e.g. PRXUP-MFT-T

V BALL VALVES

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

14-5
V Ball Control Valves with Fail-Safe Actuators
2-way Valve with Stainless Steel Ball and Stem

Valve Specifications
chilled or hot water, up to 60%
Service
glycol, steam
Flow Characteristic equal percentage
Controllable Flow Range 75° Visit www.belimo.us for additional fail-safe options.
NPT female (1” to 2”);
End Fitting
ANSI flange (3” to 6”)
Body WCC grade carbon steel
Ball stainless steel
Stem stainless steel
Seat Teflon®
Stem packing spring loaded Teflon® V-ring
Media Temperature Range
-22°F to +380°F [-30°C to +193°C]
(Water)
Media Temperature Range
-22°F to +380°F [-30°C to +193°C]
(Steam)
Max Differential Pressure
150 psi
(Water)
Max Differential Pressure
100 psi
(Steam)
Max Inlet Pressure
200 psi
(Steam)
Leakage ANSI Class IV

NFX24- AFX24- GKX24-


ACTUATOR PART # NFB24-X1 AFB24-X1 AFBUP-X1 GKB24-3-X1 PKRXUP-MFT-T
MFT-X1 MFT-X1 MFT-X1
Modulating/ Modulating/ On/Off, Modulating/
Control On/Off On/Off On/Off Modulating/MFT
MFT MFT Floating Point MFT

Manual Override • • • • • • • •
150 seconds 150 seconds 150 seconds 135 seconds (default),
Running Time (Motor) <75 seconds <75 seconds <75 seconds 90 seconds
(variable) (variable) (variable) 30-120 field adjustable
Running Time (Fail-Safe) <20 seconds <20 seconds <20 seconds <20 seconds <20 seconds 35 seconds 35 seconds 30 seconds
18 GA 18 GA
3 ft, 18 GA 3 ft, 18 GA 3 ft, 18 GA 3 ft, 18 GA 18 GA
applicance applicance
appliance appliance appliance plenum rated plenum rated
rated cable rated cable
Electrical Connection cable with cable with cable with cable with cable with terminal block
with ½” with ½”
½” conduit ½” conduit ½” conduit ½” conduit ½” conduit
conduit conduit
connector connector connector connector connector
connector connector
2-Way
Body Close-Off
Size

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


Model # Cv Pressure Pressure
[mm]
Rating [psi] [psi]
B2100VB-024 24 1” [25] 200 $2,980 $3,237 $6,816
ASME/ANSI
B2150VB-055 55 1½” [40] 200 $3,493 $3,749 $7,388
Class 300
B2200VB-077 77 2” [50] 200 $3,829 $3,903 $4,068 $7,775

All prices are in US Dollars (USD)


B6300VB-207 207 3” [80] ASME/ANSI 200 $6,636 $6,961 $7,324 $7,834 $9,738
B6400VB-350 350 4” [100] Class 150 200 $8,666 $9,175 $12,363
V BALL VALVES

2* Denotes tandem actuators.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

14-6
GLOBE VALVES
15
GLOBE VALVES

Greater Force and Flexibility


• Accurate modulation at low flow with
rangeability specification of 100:1.
• ANSI 250 and ANSI 125 pressure rating to
withstand rigorous HVAC applications.
• New soft seat design providing ANSI Class
VI leakage rating.

Steven Lopes, Product Specialist


Globe Valve Nomenclature

G2 15 B -C +LVX 24 -MFT
GLOBE VALVES

Valve Type Valve Size Trim Material Cv Actuator Type Power Supply Control
G2 = 2-way NPT NPT B = Bronze Trim -C = 0.4 Non Fail-Safe 24 = 24 VAC/DC Blank = On/Off
G3 = 3-way NPT 15 = ½” S = Stainless Trim -F = 1.3 LVB, LVX 120 = 120 VAC -3 = On/Off, Floating Point
G6 = 2-way Flanged 20 = ¾” -250 = ANSI 250 -G = 2.2 SVB, SVX UP = 24-240 VAC -SR = 2-10 VDC
G7 = 3-way Flanged 25 = 1” Bronze Trim -J = 4.4 (½”) EVB, EVX or 24-125 VDC -MFT or -MFT-X1= Multi-
32 = 1¼” S-250 = ANSI 250 -J = 5.5 (¾”) RVB, RVX Function Technology
40 = 1½” Stainless -K = 7.5 (¾”) Fail-Safe -MFT95-X1= 0-135 Ω
50 = 2” Trim -K = 10 (1”) Spring Return
Flanged C = Bronze -L = 14 LF
Trim Pressure NFB, NFX
65 = 2½” -M = 20
Compensated
80 = 3” -N = 28 (1½”) AFB, AFX
CS = Stainless Electronic
100 = 4” Trim Pressure -N = 40 (2”)
125 = 5” GKB, GKX
Compensated
150 = 6” LVKB, LVKX
LCS = Linear Stainless
SVKB, SVKX
Trim Pressure
Compensated AVKB, AVKX
D = Diverting
Bronze Trim “X” models are customizable.
DS = Diverting Refer to page 15-6 for
programming options.
Stainless Trim

Ordering Example

3 For MFT orders only - select programming code


1 Choose the valve actuator combination.

G215B-C+LVX24-MFT NO Tagging (if needed)


4
2 Specify preference or configuration.
Does order
require
Set-Up tagging?

Non Fail-Safe Models


G43 Tagging:
NO = Normally Open Valves may be tagged per
G43 2 to 10 VDC customer specification.
NC = Normally Closed
G53 0.5 to 10 VDC ($12.00 per tag)
Fail-Safe Models W3M 0.02 to 5.00 seconds PWM Example:
NO/FO = Normally Open/Fail Open G13 Floating Point AHU-1
NO/FC = Normally Open/Fail Closed FCU-2
G03 On/Off
NC/FO = Normally Closed/Fail Open Part number for tagging:
NC/FC = Normally Closed/Fail Closed 99981-00101

Refers to valve ports A to AB.

5 Complete Ordering Example: G215B-C+LVX24-MFT


Configuration: +NO
Programming: +G43
Globe Valve Product Range

Valve Nominal
Type Suitable Actuators
Size
Fail-Safe
DN 2-way 3-way Non
Cv Inches Spring
[mm] NPT NPT Fail-Safe Electronic
Return
0.4 ½ 15 G215B-C
0.4 ½ 15 G215S-C
1.3 ½ 15 G215B-F
1.3 ½ 15 G215S-F
2.2 ½ 15 G215B-G Mode of Operation
The control valve is operated by an electronic actuator that responds
2.2 ½ 15 G215S-G
to a standard voltage for on/off control, by a modulating 2-10 VDC/
4.4 ½ 15 G215B-J 4-20 mA, 3-point control system. The actuator will then move the
plug of the valve to the position dictated by the control signal thus
4.4 ½ 15 G215S-J LF Series changing the flow.
5.5 ¾ 20 G220B-J Product Features
New G2 and G3 globe valves offer a modified equal percentage flow
5.5 ¾ 20 G220S-J characteristic for a wide variety of HVAC applications. Capable of

LVK Series
LV Series

being used for heating, cooling, and steam service. Repack kits are
7.5 ¾ 20 G220B-K
available to extend the life of the valve without full replacement.
7.5 ¾ 20 G220S-K Actuator Specifications
10 1 25 G225B-K Control type on/off, floating point, 2-10 VDC,
multi-function technology (MFT)
10 1 25 G225S-K Manual override all models except LF
14 1 25 G225B-L Electrical connection 3 ft [1 m] cable with ½” conduit fitting

14 1 25 G225S-L
Valve Specifications
20 1¼ 32 G232B-M
Service chilled or hot water, 60% glycol, steam
20 1¼ 32 G232S-M Flow characteristic modified equal percentage
28 1½ 40 G240B-N G3: linear flow from B to AB
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

Sizes ½”, ¾”, 1”, 1¼”, 1½”, 2”


28 1½ 40 G240S-N End fitting NPT female
40 2 50 G250B-N Materials
Body bronze
40 2 50 G250S-N Stem stainless steel
NF Series

Plug G2B, G3B: brass


All prices are in US Dollars (USD)

2.2 ½ 15 G315B-G
G2S: stainless steel
4.4 ½ 15 G315B-J Seat G2B, G3B: bronze
G2S: stainless steel
6.75 ¾ 20 G320B-K
SVK Series

Stem packing EPDM O-ring


SV Series

14 1 25 G325B-L Media temp. range G2B, G3B: 20°F to 280°F


[-7°C to +138°C]
20 1¼ 32 G332B-M G2S: 20°F to 338°F [-7°C to +170°C]
Body pressure rating ANSI Class 250
28 1½ 40 G340B-N
Series

Maximum inlet pressure


AF

40 2 50 G350B-N Steam G2B: 35 psi [241 kPa]


G2S: 100 psi [690 kPa]
Maximum differential
pressure (∆P) G2B: 35 psi [241 kPa]
G2S: 50 psi [345 kPa]
Leakage ANSI Class VI
Rangeability 100:1

15-1
Globe Valve Product Range

Valve Nominal Size Type Suitable Actuators


Non Fail-Safe
DN Fail-Safe
Cv Inches 2-way Flanged Spring
[mm] Electronic
Return
65 2½ 65 G665C
65 2½ 65 G665CS
65 2½ 65 G665C-250
65 2½ 65 G665CS-250
65 2½ 65 G665LCS
90 3 80 G680C Mode of Operation
The control valve is operated by an electronic actuator that
90 3 80 G680CS responds to a standard voltage for on/off control, a modu-
lating 2-10 VDC/4-20 mA, or 3-point control system. The
90 3 80 G680C-250 actuator will then move the plug of the valve to the position
90 3 80 G680CS-250 dictated by the control signal thus changing the flow.
Product Features
90 3 80 G680LCS Equal percentage (G6) and linear (G7) flow curve options
170 4 100 G6100C available for a wide variety of HVAC applications. Capable of
being used for heating, cooling, and steam service. Repack
170 4 100 G6100CS and rebuild kits are available to extend the life of the valve
AVK Series
AFX Series
EV Series

without full replacement.


170 4 100 G6100C-250
Actuator Specifications
170 4 100 G6100CS-250 Control type on/off, floating point, 2-10 VDC
170 4 100 G6100LCS multi-function technology (MFT)
Manual override all models
263 5 125 G6125C Electrical connection 3 ft [1 m] cable with
263 5 125 G6125CS ½” conduit fitting

263 5 125 G6125C-250


Valve Specifications
263 5 125 G6125CS-250
Service chilled or hot water,
263 5 125 G6125LCS 60% glycol, steam

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


Flow characteristic
344 6 150 G6150C
G6 A-port equal percentage
344 6 150 G6150CS G6LCS linear
Sizes 2½”, 3”, 4”, 5”, 6”
344 6 150 G6150C-250
End fitting ANSI flanged

All prices are in US Dollars (USD)


344 6 150 G6150CS-250 Materials
Body cast iron
344 6 150 G6150LCS Stem stainless steel
The G...(C)(CS)(LCS) Series valve is a pressure compensated valve that allows high close-off ratings while Plug bronze
Seat
utilizing standard actuation. G6 stainless steel
G6...S stainless steel
Stem packing
G6 bronze trimmed: NLP (EPDM)
G6S stainless trimmed: NLP (EPDM)
Media temp. range
refer to valve specification
pages in this section
Body pressure rating
G6, 125# ANSI flange 125 psi
G6, 250# ANSI flange 250 psi
Maximum inlet pressure
Water 150 psi [1034 kPa] G6C, G6CS
250 psi [1724 kPa] G6C...250,
G6CS...250
Steam 35 psi [241 kPa] G6C, G6C...250
100 psi [690 kPa] G6CS, G6CS...250
Maximum differential
pressure (∆P)
Water 25 psi [172 kPa] G6C, G6C...250
50 psi [345 kPa] G6CS, G6CS...250
Steam 15 psi [103 kPa] G6C, G6C...250
Rangeability 85:1 (G665..), 91:1 (G680..)
98:1 (G6100..), 100:1 (G6125..)
98:1 (G6150..)
15-2
Globe Valve Product Range

Valve Nominal Size Suitable Actuators

Non Fail-Safe
Cv Inches DN [mm] 3-Way Flanged
Fail-Safe Spring Return Electronic
68 2½ 65 G765
68 2½ 65 G765S
68 2½ 65 G765-250

AVK Series
68 2½ 65 G765S-250
90 3 80 G780

EV / RV Series

AFX Series
90 3 80 G780S
90 3 80 G780-250 Mode of Operation
The control valve is operated by an electronic actuator
90 3 80 G780S-250 that responds to a standard voltage for on/off control,
190 4 100 G7100 a modulating 2-10 VDC/4-20 mA, or 3-point control system.
The actuator will then move the plug of the valve to the
190 4 100 G7100S position dictated by the control signal thus changing the
flow.
190 4 100 G7100-250
Product Features
190 4 100 G7100S-250 Equal percentage (G6) and linear (G7) flow curve options
available for a wide variety of HVAC applications. Capable of
280 5 125 G7125 being used for heating, cooling, and steam service. Repack
and rebuild kits are available to extend the life of the valve

GK Series
280 5 125 G7125S
without full replacement.
280 5 125 G7125-250 Actuator Specifications
Control type on/off, floating point, 2-10 VDC
RV Series

280 5 125 G7125S-250 multi-function technology (MFT)


340 6 150 G7150 Manual override all models
Electrical connection 3 ft [1 m] cable with
340 6 150 G7150S ½” conduit fitting

340 6 150 G7150-250


Valve Specifications
340 6 150 G7150S-250
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

Service chilled or hot water,


68 2½ 65 G765D 60% glycol
68 2½ 65 G765DS Flow characteristic linear
Sizes 2½”, 3”, 4”, 5”, 6”
68 2½ 65 G765DS-250 End fitting ANSI flanged
All prices are in US Dollars (USD)

90 3 80 G780D Materials
AVK Series

Body cast iron


90 3 80 G780DS Stem stainless steel
Plug bronze
90 3 80 G780DS-250
Seat
154 4 100 G7100D G7 stainless steel
AFX Series
EV Series

G7...S stainless steel


154 4 100 G7100DS Stem packing
G7 bronze trimmed: NLP (EPDM)
154 4 100 G7100DS-250 G7...S stainless trimmed: NLP (EPDM)
195 5 125 G7125D Media temp. range Refer to valve specification
pages in this section
195 5 125 G7125DS Body pressure rating
195 5 125 G7125DS-250 G7, 125# ANSI flange 125 psi
G7, 250# ANSI flange 250 psi
248 6 150 G7150D Maximum inlet pressure
Water 150 psi [1034 kPa] G7, G7S
248 6 150 G7150DS
250 psi [1724 kPa] G7...250,
248 6 150 G7150DS-250 G7S...250
Maximum differential
pressure (∆P)
Water 25 psi [172 kPa] G7, G7...250
50 psi [345 kPa] G7S,G7S...250
Rangeability 50:1

15-3
Threaded Globe Valves

FLOW PATTERN AND VALVE ASSEMBLY SET-UP - Specify Upon Ordering


All valves shown stem down
2-WAY VALVE (STEM UP OPEN A TO AB)
LV Series NC: Normally closed A to AB, valve NO: Normally open A to AB, valve
will open upon increase in min. will close upon increase in min.
FAIL-
SAFE
NON

signal/power. signal/ power.

LVK Series NC/FO: Normally closed A to AB with NO/FO: Normally open A to AB with NC/FC: Normally closed A to AB with NO/FC: Normally open A to AB with
power and min. signal applied. When power and min. signal applied. When power and min. signal applied. When power and min. signal applied. When
loss of power will fail open A to AB. If loss of power will fail open A to AB. If loss of power will fail closed A to AB. loss of power will fail closed A to AB.
desired both normal position and fail desired both normal position and fail If desired both normal position and If desired both normal position and
position can be reversed in field with position can be reversed in field with fail position can be reversed in field fail position can be reversed in field
ELECTRONIC FAIL-SAFE
AND SPRING RETURN

direction switch. direction switch. with direction switch. with direction switch.

LVK, LF, NF Series NC/FC: Normally closed A to AB, valve NO/FO: Normally open A to AB, valve
(on/off) will drive open with power. Fail Action: will drive open with power. Fail Action:
Flow Direction Will fail closed A to AB upon power Will fail open A to AB upon power
loss. Can be reversed with direction loss. Can be reversed with direction
G2 2-way Valve switch or actuator remounting. switch or actuator remounting.

LF, NF, Series NC/FO: Normally closed A to AB with NO/FO: Normally open A to AB with NC/FC: Normally closed A to AB with NO/FC: Normally open A to AB with
power and min. signal applied. When power and min. signal applied. When power and min. signal applied. When power and min. signal applied.
loss of power will fail open A to AB. loss of power will fail open A to AB. loss of power will fail closed A to AB. When loss of power will fail closed
If desired both normal position and If desired both normal position and If desired both normal position and A to AB. If desired both normal
fail position can be reversed in field fail position can be reversed in field fail position can be reversed in field position and fail position can be
with direction switch and actuator with direction switch and actuator with direction switch and actuator reversed in field with direction
remounting. remounting. remounting. switch and actuator remounting.

3-WAY MIXING VALVE (STEM UP OPEN B TO AB)


SV Series NC: Normally closed A to AB, valve NO: Normally open A to AB, valve
will open upon increase in min. will close upon increase in min.
FAIL-
SAFE
NON

signal/power. signal/ power.

SVK Series NC/FO: Normally closed A to AB with NO/FO: Normally open A to AB with NC/FC: Normally closed A to AB with NO/FC: Normally open A to AB with
power and min. signal applied. When power and min. signal applied. When power and min. signal applied. When power and min. signal applied. When
loss of power will fail open A to AB. If loss of power will fail open A to AB. If loss of power will fail closed A to AB. loss of power will fail closed A to AB.
desired both normal position and fail desired both normal position and fail If desired both normal position and If desired both normal position and
position can be reversed in field with position can be reversed in field with fail position can be reversed in field fail position can be reversed in field
ELECTRONIC FAIL-SAFE
AND SPRING RETURN

direction switch. direction switch. with direction switch. with direction switch.

SVK, NF, AF NC/FC: Normally closed A to AB, valve NO/FO: Normally open A to AB, valve
Series (on/off) will drive open with power. Fail Action: will drive open with power. Fail Action:
Will fail closed A to AB upon power Will fail open A to AB upon power
loss. Can be reversed with direction loss. Can be reversed with direction
switch or actuator remounting. switch or actuator remounting.
G3 3-way

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


Mixing Valve NF, AF Series NC/FO: Normally closed A to AB with NO/FO: Normally open A to AB with NC/FC: Normally closed A to AB with NO/FC: Normally open A to AB with
power and min. signal applied. When power and min. signal applied. When power and min. signal applied. When power and min. signal applied.
loss of power will fail open A to AB. loss of power will fail open A to AB. loss of power will fail closed A to AB. When loss of power will fail closed
If desired both normal position and If desired both normal position and If desired both normal position and A to AB. If desired both normal
fail position can be reversed in field fail position can be reversed in field fail position can be reversed in field position and fail position can be
with direction switch and actuator with direction switch and actuator with direction switch and actuator reversed in field with direction

All prices are in US Dollars (USD)


remounting. remounting. remounting. switch and actuator remounting.

3-WAY DIVERTING VALVE (STEM UP OPEN AB TO B)


SV Series NC: Normally closed AB to A, valve NO: Normally open AB to A, valve
will open upon increase in min. will close upon increase in min.
FAIL-
SAFE
NON

signal/power. signal/ power.

SVK Series NC/FO: Normally closed AB to A with NO/FO: Normally open AB to A with NC/FC: Normally closed AB to A with NO/FC: Normally open AB to A with
power and min. signal applied. When power and min. signal applied. When power and min. signal applied. When power and min. signal applied. When
loss of power will fail open AB to A. If loss of power will fail open AB to A. If loss of power will fail closed AB to A. loss of power will fail closed AB to A.
desired both normal position and fail desired both normal position and fail If desired both normal position and If desired both normal position and
position can be reversed in field with position can be reversed in field with fail position can be reversed in field fail position can be reversed in field
ELECTRONIC FAIL-SAFE
GLOBE VALVES

AND SPRING RETURN

direction switch. direction switch. with direction switch. with direction switch.

SVK, NF, AF NC/FC: Normally closed AB to A, valve NO/FO: Normally open AB to A, valve
Series (on/off) will drive open with power. Fail Action: will drive open with power. Fail Action:
Will fail closed AB to A upon power Will fail open AB to A upon power
G3 3-way loss. Can be reversed with direction loss. Can be reversed with direction
Diverting Valve switch or actuator remounting. switch or actuator remounting.

NF, AF Series NC/FO: Normally closed AB to A with NO/FO: Normally open AB to A with NC/FC: Normally closed AB to A with NO/FC: Normally open AB to A with
power and min. signal applied. When power and min. signal applied. When power and min. signal applied. When power and min. signal applied.
loss of power will fail open AB to A. loss of power will fail open AB to A. loss of power will fail closed AB to A. When loss of power will fail closed
If desired both normal position and If desired both normal position and If desired both normal position and AB to A. If desired both normal
fail position can be reversed in field fail position can be reversed in field fail position can be reversed in field position and fail position can be
with direction switch and actuator with direction switch and actuator with direction switch and actuator reversed in field with direction
remounting. remounting. remounting. switch and actuator remounting.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

15-4
Flanged Globe Valves

FLOW PATTERN – Flow Pattern is Marked on Valve

G6 2-way Valve G7 3-way Mixing Valve G7…D 3-way Diverting Valve


Stem Up = Open A to AB Stem Up = Open B to AB Stem Up = Open AB to B

A AB A B
Flow arrow shown
on rear of valve B AB

VALVE ASSEMBLY SET-UP - Specify Upon Ordering

2-WAY VALVE
FAIL-SAFE

NC: Normally closed A to AB, valve will open upon increase in signal/power. NO: Normally open A to AB, valve will close upon increase in signal/power.
NON

EV, RV Series
Note: To change valve to A to AB open, reverse the directional switch in actuator. Note: To change valve to A to AB closed, reverse the directional switch in actuator.

AFB, AFX Series NO/FO: Normally open A to AB valve will drive closed. Spring Action: Will fail open A to NC/FC: Normally closed A to AB valve will drive open. Spring Action: Will fail closed
SPRING RETURN

On/Off AB upon power loss. A to AB upon power loss.

NO/FC or NC/FC: Normally Open/Normally Closed: valve can be open or closed,


will drive closed or open A to AB (can be chosen with CW/CCW switch). Spring
NC/FO: Normally closed A to AB, valve will open upon increase in signal. Note: To
AFB, AFX MFT Action: Closed A to AB upon power loss.
change valve to A to AB open, reverse CW/CCW switch. Spring Action: Will fail open A to
Series
AB upon power loss. NO/FO: Normally open A to AB. Spring Action: Will fail open A to AB upon power
loss. (NO or NC action can be chosen with CW/CCW switch).

NO/FC or NC/FC: Valve: Can be open or closed, will drive closed or open A to AB
ELECTRONIC

(can be chosen with CW/CCW switch). Fail Position: Will default fail A to AB open,
FAIL-SAFE

NC/FO: Normally closed A to AB, valve will open upon increase in signal. Note: To
AVK, GK Series change valve to A to AB open, reverse CW/CCW switch.Fail Position: Will default fail A to from the factory. Fail position can be set from 0%-100%, in 10% increments.
AB open, from the factory. Fail position can be set from 0%-100%, in 10% increments. NO/FO: Normally open A to AB. Fail Position: Will default fail A to AB open, from the
factory. Fail position can be set from 0%-100%, in 10% increments.

3-WAY MIXING VALVE


FAIL-SAFE

NC: Normally closed A to AB, will open upon increase in signal/power. NO: Normally open A to AB, will close upon increase in signal/power.
NON

EV, RV Series
Note: To change valve to A to AB open, reverse the directional switch in actuator. Note: To change valve to A to AB closed, reverse the directional switch in actuator.

AFB, AFX Series NO/FO Normally open A to AB, valve will drive closed. Spring Action: Will fail open A to NC/FC Normally closed A to AB, valve will drive open. Spring Action: Will fail closed
On/Off AB upon power loss. A to AB upon power loss.
SPRING RETURN
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

NO/FC or NC/FC Normally Open/Normally Closed: valve be open or closed, will


drive closed or open A to AB (can be chosen with CW/CCW switch). Spring
NC/FO Normally closed A to AB, valve will open upon increase in signal. Note: To change
AFB, AFX MFT Action: Closed A to AB upon power loss.
valve to A to AB open, reverse CW/CCW switch. Spring Action: Will fail open A to AB
Series
upon power loss. NO/FO Normally open A to AB. Spring Action: Will fail open A to AB upon power
loss. (NO or NC action can be chosen with CW/CCW switch).
All prices are in US Dollars (USD)

NO/FC or NC/FC Valve: Can be open or closed, will drive closed or open A to AB
ELECTRONIC

(can be chosen with CW/CCW switch). Fail Position: Will default fail A to AB open,
FAIL-SAFE

NC/FO Normally closed A to AB, valve will open upon increase in signal. Note: To change
AVK, GK Series valve to A to AB open, reverse CW/CCW switch. Fail Position: Will default fail A to AB from the factory. Fail position can be set from 0%-100%, in 10% increments.
open, from the factory. Fail position can be set from 0%-100%, in 10% increments. NO/FO Normally open A to AB. Fail Position: Will default fail A to AB open, from the
factory. Fail position can be set from 0%-100%, in 10% increments.

3-WAY DIVERTING VALVE


FAIL-SAFE

NC: Normally closed AB to B, will open upon increase in signal/power. NO: Normally open AB to B, will close upon increase in signal/power.
NON

EV, RV Series
Note: To change valve to AB to B open, reverse the directional switch in actuator. Note: To change valve to AB to B closed, reverse the directional switch in actuator.
GLOBE VALVES

AFB, AFX Series NO/FO Normally open AB to B, valve will drive closed. Spring Action: Will fail open AB to NC/FC Normally closed AB to B, valve will drive open. Spring Action: Will fail closed
On/Off B upon power loss. AB to B upon power loss.
SPRING RETURN

NO/FC or NC/FC Normally Open/Normally Closed: valve be open or closed, will


drive closed or open AB to B (can be chosen with CW/CCW switch). Spring
NC/FO Normally closed AB to B, valve will open upon increase in signal. Note: To change
AFB, AFX MFT Action: Closed AB to B upon power loss.
valve to AB to B open, reverse CW/CCW switch. Spring Action: Will fail open AB to B
Series
upon power loss. NO/FO Normally open AB to B. Spring Action: Will fail open AB to B upon power
loss. (NO or NC action can be chosen with CW/CCW switch).

NO/FC or NC/FC Valve: Can be open or closed, will drive closed or open AB to B
ELECTRONIC

(can be chosen with CW/CCW switch). Fail Position: Will default fail AB to B open,
FAIL-SAFE

NC/FO Normally closed AB to B, valve will open upon increase in signal. Note: To change
AVK, GK Series valve to AB to B open, reverse CW/CCW switch. Fail Position: Will default fail AB to B from the factory. Fail position can be set from 0%-100%, in 10% increments.
open, from the factory. Fail position can be set from 0%-100%, in 10% increments. NO/FO Normally open AB to B. Fail Position: Will default fail AB to B open, from the
factory. Fail position can be set from 0%-100%, in 10% increments.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

15-5
Customize Products
Default and MFT Programming Codes

CONTROL
CONFIGURATION
ACTUATOR TYPE P-CODE CONTROL INPUT FEEDBACK POSITION RUNNING TIME List Price
DESCRIPTION
-3 and -SR N/A 0 2-10 VDC (for -3) 2-10 VDC (for -3) 150 seconds No Charge
N/A 2 2-10 VDC (for -SR) 2-10 VDC (for -SR) 90 seconds No Charge
-MFT and -PC P-10001 A01 2-10 VDC 2-10 VDC 150 seconds No Charge*
P-10002 A02 0.5-10 VDC 0-10 VDC 150 seconds $37
P-10003 A03 2-10 VDC 0-5.0 VDC 150 seconds No Charge
P-10004 A04 4-7 VDC 2-10 VDC 150 seconds $37
P-10005 A05 6-9 VDC 2-10 VDC 150 seconds $37
P-10006 A06 10.5 -13.5 VDC 2-10 VDC 150 seconds $37
P-10007 A07 0.5-5 VDC 2-10 VDC 150 seconds $37
P-10009 A09 5-10 VDC 2-10 VDC 150 seconds $37
P-10010 A10 5-10 VDC 0-10 VDC 150 seconds $37
P-10013 A13 0.5-10 VDC 2-10 VDC 150 seconds $37
P-10015 A15 2-5 VDC 2-10 VDC 150 seconds $37
P-10016 A16 2-6 VDC 2-10 VDC 150 seconds $37
ROTARY ACTUATOR

P-10017 A17 6-10 VDC 2-10 VDC 150 seconds $37


P-10018 A18 14-17 VDC 2-10 VDC 150 seconds $37
P-10019 A19 2-10 VDC 2-10 VDC 100 seconds No Charge
P-10020 A20 9-12 VDC 2-10 VDC 150 seconds $35
P-10028 A28 0.5-10 VDC 0.5-10 VDC 100 seconds No Charge
P-10031 A31 0.5- 4 VDC 2-10 VDC 150 seconds $37
P-10063 A63 0.5-4.5 VDC 0.5- 4.5 VDC 150 seconds No Charge
P-10032 A32 6-14 VDC 2-10 VDC 150 seconds $37
P-10064 A64 5.5-10 VDC 5.5-10.0 VDC 150 seconds No Charge
N/A AAT 2-10 VDC 2-10 VDC 20 seconds No Charge
P-20001 W01 0.59-2.93 seconds 2-10 VDC 150 seconds $37
P-20002 W02 0.02 to 5.00 seconds 2-10 VDC 150 seconds No Charge
P-20003 W03 0.10 to 25.50 seconds 2-10 VDC 150 seconds No Charge
P-20004 W04 0.10 to 25.60 seconds 2-10 VDC 150 seconds $37
P-20005 W05 0.10 to 5.20 seconds 0-5.0 VDC 150 seconds $37
P-30001 F01 Floating Point 2-10 VDC 150 seconds No Charge
P-30002 F02 Floating Point 0-10 VDC 150 seconds $37
P-40002 J02 On/Off 2-10 VDC 150 seconds No Charge
N/A S01 (for -PC only) Phasecut 2-10 VDC 150 seconds No Charge
P-16001 R01 (for -MFT95 only) 0 to 135 Ω 2-10 VDC 150 seconds No Charge
-3 and -MFT G01 On/Off 2-10 VDC MFT only 35 seconds No Charge
G02 On/Off 2-10 VDC MFT only 60 seconds No Charge
G03 On/Off 2-10 VDC MFT only 90 seconds No Charge

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


G04 On/Off 2-10 VDC MFT only 150 seconds No Charge
G11 Floating Point 2-10 VDC MFT only 35 seconds No Charge
G12 Floating Point 2-10 VDC MFT only 60 seconds No Charge
G13 Floating Point 2-10 VDC MFT only 90 seconds No Charge
G14 Floating Point 2-10 VDC MFT only 150 seconds No Charge

All prices are in US Dollars (USD)


-SR and -MFT G41 (G21 for -SR) 2-10 VDC 2-10 VDC 35 seconds No Charge
LINEAR ACTUATOR

G42 (G22 for -SR) 2-10 VDC 2-10 VDC 60 seconds No Charge
G43 (G23 for -SR) 2-10 VDC 2-10 VDC 90 seconds No Charge
G44 (G24 for -SR) 2-10 VDC 2-10 VDC 150 seconds No Charge
-MFT G51 0.5-10 VDC 0.5-10 VDC 35 seconds No Charge
G52 0.5-10 VDC 0.5-10 VDC 60 seconds No Charge
G53 0.5-10 VDC 0.5-10 VDC 90 seconds No Charge
G54 0.5-10 VDC 0.5-10 VDC 150 seconds No Charge
G2A 5.5-10 VDC 5.5-10 VDC 150 seconds No Charge
G2B 0.5-4.5 VDC 0.5-4.5 VDC 150 seconds No Charge
G2C 2-10 VDC 0.5-5 VDC 150 seconds No Charge
G2D 6-9 VDC 2-10 VDC 150 seconds No Charge
G2E 10.5-13.5 VDC 2-10 VDC 150 seconds No Charge
GLOBE VALVES

W3M** 0.02-5.00 seconds PWM 2-10 VDC 90 seconds No Charge


W3P** 0.2-5.00 seconds PWM 2-10 VDC 90 seconds No Charge
*P-10001 is the default configuration for MFT.
**Not available on RV models.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

15-6
G2…B/G3…B Series Globe Valves with Non Fail-Safe Actuators
2-way and 3-way Valves with Bronze Trim, NPT Female Ends

Valve Specifications
G2: chilled or hot water,
60% glycol, steam
Service
G3: chilled or hot water,
60% glycol
modified equal percentage,
Flow Characteristic
G3B linear flow from B to AB
G2B: stem up - open A to AB
G3B (mixing): stem up - open B to AB
Action
G3B (diverting): stem up - open
AB to B
End Fitting NPT female
Body bronze
Seat bronze
Stem stainless steel
Stem Packing EPDM O-ring
Plug brass
Media Temperature 20°F to 280°F [-7°C to +138°C]
Max Diff Pressure (∆P) 35 psi [241 kPa]
Max Inlet Pressure
35 psi [241 kPa]
(Steam)
Leakage ANSI Class VI

ACTUATOR PART # LVB24-3 LVB24-SR LVX24-MFT SVB24-3 SVB24-SR SVX24-MFT


Control On/Off, Floating Point Modulating Modulating/MFT On/Off, Floating Point Modulating Modulating/MFT
Manual Override • • • • • •
Running Time (Motor) 90 seconds 90 seconds 90 seconds (variable) 90 seconds 90 seconds 90 seconds (variable)
3 ft, 18 GA plenum 3 ft, 18 GA plenum 3 ft, 18 GA plenum 3 ft, 18 GA plenum 3 ft, 18 GA plenum 3 ft, 18 GA plenum
Electrical Connection rated cable with ½” rated cable with ½” rated cable with ½” rated cable with ½” rated cable with ½” rated cable with ½”
conduit connector conduit connector conduit connector conduit connector conduit connector conduit connector

2-Way
Body Close-Off
Size
Model # Cv Pressure Pressure
[mm]
Rating [psi]
G215B-C 0.4 250 $861 $957 $1,017
G215B-F 1.3 250 $864 $960 $1,020
½” [15]
G215B-G 2.2 250 $867 $963 $1,023
G215B-J 4.4 250 $870 $966 $1,026
G220B-J 5.5 250 $878 $975 $1,034
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

¾” [20]
G220B-K 7.5 ANSI 250 250 $884 $981 $1,040
G225B-K 10 250 $961 $1,058 $1,117
1” [25]
G225B-L 14 250 $971 $1,067 $1,127
G232B-M 20 1¼” [32] 250 $1,051 $1,147 $1,207
G240B-N 28 1½” [40] 250 $1,209 $1,305 $1,365
All prices are in US Dollars (USD)

G250B-N 40 2” [50] 250 $1,373 $1,470 $1,529


3-Way

Body Close-Off
Size Pressure [psi]
Model # Cv Pressure
[mm]
Rating
Mixing Diverting
G315B-G 2.2 250 250 $939 $1,036 $1,097
½” [15]
G315B-J 4.4 250 250 $943 $1,040 $1,101
G320B-K 6.75 ¾” [20] 250 182 $947 $1,044 $1,105
G325B-L 14 1” [25] ANSI 250 250 109 $1,021 $1,118 $1,179
G332B-M 20 1¼” [32] 246 82 $1,119 $1,217 $1,278
G340B-N 28 1½” [40] 137 46 $1,488 $1,586 $1,646
GLOBE VALVES

G350B-N 41 2” [50] 86 29 $1,647 $1,745 $1,805

Prices do not reflect additional programming codes surcharge. See page 15-6 for linear actuator MFT codes. Note: All ”B” versions available as customizable ”X” versions.
Please see www.belimo.us for details.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

15-7
G2…B/G3…B Series Globe Valves with Electronic Fail-Safe Actuators
2-way and 3-way Valves with Bronze Trim, NPT Female Ends

Valve Specifications
G2: chilled or hot water,
60% glycol, steam
Service
G3: chilled or hot water,
60% glycol
modified equal percentage
Flow Characteristic
G3B: linear flow from B to AB
G2B: stem up - open A to AB
G3B: (mixing): stem up - open B to AB
Action
G3B: (diverting): stem up - open
AB to B
End Fitting NPT female
Body bronze
Seat bronze
Stem stainless steel
Stem Packing EPDM O-ring
Plug brass
Media Temperature 20°F to 280°F [-7°C to +138°C]
Max Diff Pressure (∆P) 35 psi [241 kPa]
Max Inlet Pressure
35 psi [241 kPa]
(Steam)
Leakage ANSI Class VI

ACTUATOR PART # LVKB24-3 LVKB24-SR LVKB24-MFT SVK24-3 SVKB24-SR SVKB24-MFT


Control On/Off, Floating Point Modulating Modulating/MFT On/Off, Floating Point Modulating Modulating/MFT
Manual Override • • • • • •
Running Time (Motor) 90 seconds 90 seconds 90 seconds (variable) 90 seconds 90 seconds 90 seconds (variable)
Running Time (Fail-Safe) 35 seconds 35 seconds 35 seconds 35 seconds 35 seconds 35 seconds
3 ft, 18 GA plenum 3 ft, 18 GA plenum 3 ft, 18 GA plenum 3 ft, 18 GA plenum 3 ft, 18 GA plenum 3 ft, 18 GA plenum
Electrical Connection rated cable with ½” rated cable with ½” rated cable with ½” rated cable with ½” rated cable with ½” rated cable with ½”
conduit connector conduit connector conduit connector conduit connector conduit connector conduit connector

2-Way
Body Close-Off
Size
Model # Cv Pressure Pressure
[mm]
Rating [psi]
G215B-C 0.4 250 $1,028 $1,113 $1,174
G215B-F 1.3 250 $1,031 $1,116 $1,176
½” [15]
G215B-G 2.2 250 $1,034 $1,119 $1,179
G215B-J 4.4 250 $1,037 $1,123 $1,182

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


G220B-J 5.5 250 $1,096 $1,181 $1,241
¾” [20]
G220B-K 7.5 ANSI 250 250 $1,103 $1,188 $1,248
G225B-K 10 250 $1,217 $1,302 $1,362
1” [25]
G225B-L 14 250 $1,225 $1,310 $1,370
G232B-M 20 1¼” [32] 250 $1,352 $1,437 $1,496

All prices are in US Dollars (USD)


G240B-N 28 1½” [40] 250 $1,438 $1,523 $1,583
G250B-N 40 2” [50] 250 $1,689 $1,775 $1,834
3-Way

Body Close-Off
Size Pressure [psi]
Model # Cv Pressure
[mm]
Rating
Mixing Diverting
G315B-G 2.2 250 250 $1,100 $1,184 $1,247
½” [15]
G315B-J 4.4 250 250 $1,104 $1,188 $1,251
G320B-K 6.75 ¾” [20] 250 182 $1,157 $1,242 $1,304
G325B-L 14 1” [25] ANSI 250 250 109 $1,292 $1,376 $1,439
G332B-M 20 1¼” [32] 246 82 $1,515 $1,599 $1,662
GLOBE VALVES

G340B-N 28 1½” [40] 137 46 $1,758 $1,842 $1,905


G350B-N 41 2” [50] 86 29 $2,027 $2,112 $2,174

Prices do not reflect additional programming codes surcharge. See page 15-6 for linear actuator MFT codes. Note: All ”B” versions available as customizable ”X” versions.
Please see www.belimo.us for details.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

15-8
G2…S Series Globe Valves with Non Fail-Safe Actuators
2-way Valve with Stainless Steel Trim, NPT Female Ends

Valve Specifications
chilled, hot water, 60% glycol,
Service
steam
Flow Characteristic modified equal percentage
Action stem up - open A to AB
End Fitting NPT female
Body bronze
Seat stainless steel
Stem stainless steel
Stem Packing EPDM O-ring
Plug stainless steel
Media Temperature 20°F to 338°F [-7°C to +170°C]
Max Diff Pressure (∆P) 50 psi [345 kPa]
Max Inlet Pressure
100 psi [690 kPa]
(Steam)
Leakage ANSI Class VI

ACTUATOR PART # LVB24-3 LVB24-SR LVX24-MFT


Control On/Off, Floating Point Modulating Modulating/MFT
Manual Override • • •
Running Time (Motor) 90 seconds 90 seconds 90 seconds (variable)

3 ft, 18 GA plenum rated cable with 3 ft, 18 GA plenum rated cable with 3 ft, 18 GA plenum rated cable with
Electrical Connection
½” conduit connector ½” conduit connector ½” conduit connector

2-Way
Body Close-Off
Size
Model # Cv Pressure Pressure
[mm]
Rating [psi]
G215S-C 0.4 250 $1,215 $1,309 $1,370
G215S-F 1.3 250 $1,218 $1,313 $1,373
½” [15]
G215S-G 2.2 250 $1,221 $1,316 $1,376
G215S-J 4.4 250 $1,224 $1,319 $1,379
G220S-J 5.5 250 $1,343 $1,438 $1,498
¾” [20]
G220S-K 7.5 ANSI 250 250 $1,349 $1,444 $1,505
G225S-K 10 250 $1,531 $1,626 $1,686
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

1” [25]
G225S-L 14 250 $1,537 $1,632 $1,692
G232S-M 20 1¼” [32] 250 $1,828 $1,923 $1,983
G240S-N 28 1½” [40] 250 $2,169 $2,264 $2,324
G250S-N 40 2” [50] 250 $2,418 $2,512 $2,573
All prices are in US Dollars (USD)

Prices do not reflect additional programming codes surcharge. See page 15-6 for linear actuator MFT codes. Note: All ”B” versions available as customizable ”X” versions.
Please see www.belimo.us for details.

GLOBE VALVES

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

15-9
G2…S Series Globe Valves with Electronic Fail-Safe Actuators
2-way Valve with Stainless Steel Trim, NPT Female Ends

Valve Specifications
chilled, hot water, 60% glycol,
Service
steam
Flow Characteristic modified equal percentage
Action stem up - open A to AB
End Fitting NPT female
Body bronze
Seat stainless steel
Stem stainless steel
Stem Packing EPDM O-ring
Plug stainless steel
Media Temperature 20°F to 338°F [-7°C to +170°C]
Max Diff Pressure (∆P) 50 psi [345kPa]
Max Inlet Pressure
100 psi [690 kPa]
(Steam)
Leakage ANSI Class VI

ACTUATOR PART # LVKB24-3 LVKB24-SR LVKB24-MFT


Control On/Off, Floating Point Modulating Modulating/MFT
Manual Override • • •
Running Time (Motor) 90 seconds 90 seconds 90 seconds (variable)
Running Time (Fail-Safe) 35 seconds 35 seconds 35 seconds

3 ft, 18 GA plenum rated cable with 3 ft, 18 GA plenum rated cable with 3 ft, 18 GA plenum rated cable with
Electrical Connection
½” conduit connector ½” conduit connector ½” conduit connector

2-Way
Body Close-Off
Size
Model # Cv Pressure Pressure
[mm]
Rating [psi]
G215S-C 0.4 250 $1,384 $1,469 $1,529
G215S-F 1.3 250 $1,387 $1,472 $1,532
½” [15]
G215S-G 2.2 250 $1,391 $1,475 $1,535
G215S-J 4.4 250 $1,394 $1,478 $1,538
G220S-J 5.5 250 $1,515 $1,599 $1,660
¾” [20]
G220S-K 7.5 ANSI 250 250 $1,524 $1,608 $1,669

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


G225S-K 10 250 $1,812 $1,896 $1,956
1” [25]
G225S-L 14 250 $1,873 $1,957 $2,018
G232S-M 20 1¼” [32] 250 $2,251 $2,335 $2,396
G240S-N 28 1½” [40] 250 $2,623 $2,707 $2,768
G250S-N 40 2” [50] 250 $2,896 $2,980 $3,041

All prices are in US Dollars (USD)


Prices do not reflect additional programming codes surcharge. See page 15-6 for linear actuator MFT codes. Note: All ”B” versions available as customizable ”X” versions.
Please see www.belimo.us for details.
GLOBE VALVES

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

15-10
G2 Series Globe Valves with Spring Return Actuators
2-way Valve with Bronze Trim / Stainless Steel Trim, NPT Female Ends

Valve Specifications
chilled, hot water, 60% glycol,
Service
steam
Flow Characteristic modified equal percentage
Action stem up - open A to AB Visit www.belimo.us for additional Spring Return options.
End Fitting NPT female
Body bronze
G2B: bronze
Seat
G2S: stainless steel
Stem stainless steel
Stem Packing EPDM O-ring
G2B: brass
Plug
G2S: stainless steel
G2B: 20°F to 280°F
[-7°C to +138°C]
Media Temperature
G2S: 20°F to 338°F
[-7°C to +170°C]
G2B: 35 psi [241 kPa]
Max Diff Pressure (∆P) G2S: 50 psi [345 kPa]
Max Inlet Pressure G2B: 35 psi [241 kPa]
(Steam) G2S: 100 psi [690 kPa]
Leakage ANSI Class VI

ACTUATOR PART # LF24 US LF24-SR US LF24-MFT US NFBUP-X1 NFB24-SR-X1 NFX24-MFT-X1

Control On/Off Modulating Modulating/MFT On/Off Modulating Modulating/MFT

Manual Override • • •
150 seconds 150 seconds
Running Time (Motor) 75 seconds 150 seconds <75 seconds 95 seconds
(variable) (variable)
Running Time (Fail-Safe) <25 seconds <25 seconds <25 seconds <20 seconds <20 seconds <20 seconds
3 ft, 18 GA appliance 3 ft, 18 GA plenum 3 ft, 18 GA appliance 3 ft, 18 GA appliance 3 ft, 18 GA appliance 3 ft, 18 GA appliance
Electrical Connection cable, ½” conduit cable with ½” conduit cable, ½” conduit cable, ½” conduit cable, ½” conduit cable, ½” conduit
connector connector connector connector connector connector

2-Way
Body Close-Off
Size
Model # Cv Pressure Pressure
[mm]
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

Rating [psi]
G215B-C 0.4 160 $1,217 $1,333 $1,406
G215B-F 1.3 160 $1,219 $1,336 $1,410
½” [15]
G215B-G 2.2 160 $1,221 $1,339 $1,412
G215B-J 4.4 160 $1,224 $1,341 $1,414
All prices are in US Dollars (USD)

G220B-J 5.5 155 $1,256 $1,371 $1,446


¾” [20]
G220B-K 7.5 ANSI 250 155 $1,258 $1,377 $1,453
G225B-K 10 147 $1,326 $1,447 $1,628
1” [25]
G225B-L 14 147 $1,328 $1,450 $1,630
G232B-M 20 1¼” [32] 141 $1,427 $1,550 $1,732
G240B-N 28 1½” [40] 250 $1,879 $1,955 $2,032
G250B-N 40 2” [50] 250 $1,948 $2,097 $2,104

2-Way
G215S-C 0.4 160 $1,551 $1,671 $1,747
G215S-F 1.3 160 $1,553 $1,673 $1,749
½” [15]
G215S-G 2.2 160 $1,555 $1,675 $1,752
G215S-J 4.4 160 $1,557 $1,677 $1,754
GLOBE VALVES

G220S-J 5.5 155 $1,597 $1,931 $2,007


¾” [20]
G220S-K 7.5 ANSI 250 155 $1,599 $1,933 $2,009
G225S-K 10 147 $1,843 $1,976 $2,162
1” [25]
G225S-L 14 147 $1,846 $1,979 $2,165
G232S-M 20 1¼” [32] 141 $2,204 $2,345 $2,527
G240S-N 28 1½” [40] 250 $2,875 $2,954 $3,030
G250S-N 40 2” [50] 250 $3,104 $3,183 $3,254

Prices do not reflect additional programming codes surcharge. See page 15-6 for linear actuator MFT codes. Note: All ”B” versions available as customizable ”X” versions.
Please see www.belimo.us for details.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

15-11
G3 Series Globe Valves with Spring Return Actuators
3-way Valve with Bronze Trim, Mixing and Diverting, NPT Female Ends

Valve Specifications
Service chilled, hot water, 60% glycol
modified equal percentage
Flow Characteristic
linear flow from B to AB
mixing: stem up - open B to AB
Action Visit www.belimo.us for additional Spring Return options.
diverting: stem up - open AB to B
End Fitting NPT female
Body bronze
Seat bronze
Stem stainless steel
Stem Packing EPDM O-ring
Plug brass
Media Temp. Water 20°F to 280°F [-7°C to +138°C]
Max Diff Pressure (∆P) 35 psi [241 kPa]
Leakage ANSI Class VI

ACTUATOR PART # NFBUP-X1 NFB24-SR-X1 NFX24-MFT-X1 AFBUP-X1 AFB24-SR-X1 AFX24-MFT-X1

Control On/Off Modulating Modulating/MFT On/Off 2-10 VDC Modulating/MFT

Manual Override • • • • • •
150 seconds 150 seconds
Running Time (Motor) <75 seconds 95 seconds <75 seconds <75 seconds
(variable) (variable)
Running Time (Fail-Safe) <20 seconds <20 seconds < 20 seconds <20 seconds <20 seconds < 20 seconds
3 ft, 18 GA appliance 3 ft, 18 GA appliance 3 ft, 18 GA appliance 3 ft, 18 GA appliance 3 ft, 18 GA appliance 3 ft, 18 GA appliance
Electrical Connection cable, ½” conduit cable, ½” conduit cable, ½” conduit cable, ½” conduit cable, ½” conduit cable, ½” conduit
connector connector connector connector connector connector

3-Way

Body Close-Off
Size Pressure [psi]
Model # Cv Pressure
[mm]
Rating
Mixing Diverting
G315B-G 2.2 250 166 $1,405 $1,480 $1,555
½” [15]
G315B-J 4.4 250 166 $1,407 $1,482 $1,557
G320B-K 6.75 ¾” [20] 250 101 $1,439 $1,517 $1,595

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


G325B-L 14 1” [25] ANSI 250 179 60 $1,458 $1,581 $1,761
G332B-M 20 1¼” [32] 133 44 $1,555 $1,680 $1,872
G340B-N 28 1½” [40] 167 56 $2,114 $2,192 $2,268
G350B-N 40 2” [50] 105 35 $2,191 $2,270 $2,345

All prices are in US Dollars (USD)


Prices do not reflect additional programming codes surcharge. See page 15-6 for linear actuator MFT codes. Note: All ”B” versions available as customizable ”X” versions.
Please see www.belimo.us for details.
GLOBE VALVES

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

15-12
G6...C/G7...(D) Series Flanged Globe Valves with Non Fail-Safe Actuators
2-way and 3-way Valves with Bronze Trim – ANSI 125 Flanged

Valve Specifications
(G6) chilled, hot water, 60%
Service G6,G7 glycol, steam;
(G7) chilled, hot water, 60% glycol
(G6) equal percentage;
Flow Characteristic G6, G7
(G6LCS, G7) linear
Action G6 stem up - open A to AB
Action G7 stem up - open B to AB
Action G7D stem up - open AB to B
End Fitting 125 lb. flanged
Body cast iron - ASTM A126 Class B
Seat stainless steel
Stem stainless steel
Stem Packing NLP (no lip packing) (EPDM)
Plug bronze
Media Temp. Water G6 32°F to 300°F [0°C to 149°C]
Media Temp. Steam G6 32°F to 280°F [0°C to 138°C]
Media Temp. Water G7 32°F to 350°F [0°C to 176°C]
32°F to 300°F [0°C to 149°C]
Media Temp. Water G7D
6”only: 32°F to 150°F [0°C to 66°C]
Max Differential Pressure
25 psi [172 kPa]
(Water)
Max Differential Pressure
15 psi [103 kPa]
(Steam) G6
Leakage ANSI Class III
Max Inlet PSI (Water)
150 psi [1034 kPa] @ 250°F
G6, G7
Max Inlet Pressure
35 psi [241 kPa]
(Steam) G6

ACTUATOR PART # EVB24-3 EVB24-SR EVB24-MFT RVB24-3 RVB24-MFT


Control On/Off, Floating Point Modulating Modulating/MFT On/Off, Floating Point Modulating/MFT
Manual Override • • • • •
Running Time (Motor) 90 seconds 90 seconds 90 seconds (variable) 90 seconds 90 seconds (variable)
3 ft, 18 GA plenum rated 3 ft, 18 GA plenum rated 3 ft, 18 GA plenum rated 3 ft, 18 GA plenum rated 3 ft, 18 GA plenum rated
Electrical Connection cable with ½” conduit cable with ½” conduit cable with ½” conduit cable with ½” conduit cable with ½” conduit
connector connector connector connector connector
2-Way
Body Close-Off
Size
Model # Cv Pressure Pressure
[mm]
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

Rating [psi]
G665C 65 2½” [65] 140 $2,994 $3,093 $3,154
G680C 90 3” [80] 140 $3,326 $3,424 $3,484
G6100C 170 4” [100] ANSI 125 140 $4,189 $4,288 $4,349
G6125C 263 5” [125] 140 $6,223 $6,322 $6,382
All prices are in US Dollars (USD)

G6150C 344 6” [150] 140 $6,777 $6,874 $6,936


3-Way Mixing
G765 68 106 $3,024 $3,121 $3,672
2½” [65]
G765 68 125 $3,915 $4,074
G780 90 73 $3,299 $3,396 $3,690
3” [80]
G780 90 125 $4,180 $4,339
ANSI 125
G7100 190 40 $4,093 $4,190 $4,254
4” [100]
G7100 190 75 $4,816 $4,973
G7125 280 5” [125] 47 $7,005 $7,166
G7150 340 6” [150] 32 $7,810 $7,968
3-Way Diverting
G765D 68 2½” [65] 140 $5,808 $5,905 $5,968
GLOBE VALVES

G780D 90 3” [80] 140 $6,540 $6,638 $6,702


G7100D 154 4” [100] ANSI 125 140 $7,589 $7,687 $7,749
G7125D 195 5” [125] 140 $10,148 $10,247 $10,185
G7150D 248 6” [150] 140 $12,762 $12,859 $12,920

Prices do not reflect additional programming codes surcharge. See page 15-6 for linear actuator MFT codes. Note: All ”B” versions available as customizable ”X” versions.
Please see www.belimo.us for details.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

15-13
G6...C/G7...(D) Series Flanged Globe Valves with Spring Return Actuators
2-way and 3-way Valves with Bronze Trim– ANSI 125 Flanged

Valve Specifications
(G6) chilled, hot water, 60%
Service G6,G7 glycol, steam;
(G7) chilled, hot water, 60% glycol
(G6) equal percentage;
Flow Characteristic G6, G7
(G6LCS, G7) linear Visit www.belimo.us for additional Spring Return options.
Action G6 stem up - open A to AB
Action G7 stem up - open B to AB
Action G7D stem up - open AB to B
End Fitting 125 lb. flanged
Body cast iron - ASTM A126 Class B
Seat stainless steel
Stem stainless steel
Stem Packing NLP (no lip packing) (EPDM)
Plug bronze
Media Temp. Water G6 32°F to 300°F [0°C to 149°C]
Media Temp. Steam G6 32°F to 280°F [0°C to 138°C]
Media Temp. Water G7 32°F to 350°F [0°C to 176°C]
32°F to 300°F [0°C to 149°C]
Media Temp. Water G7D
6”only: 32°F to 150°F [0°C to 66°C]
Max Differential Pressure
25 psi [172 kPa]
(Water)
Max Differential Pressure
15 psi [103 kPa]
(Steam) G6
Leakage ANSI Class III
Max Inlet PSI (Water)
150 psi [1034 kPa] @ 250°F
G6, G7
Max Inlet Pressure
35 psi [241 kPa]
(Steam) G6

ACTUATOR PART # AFBUP-X1 AFX24-MFT-X1 2*AFBUP-X1 2*AFX24-MFT-X1


Control On/Off Modulating/MFT On/Off Modulating/MFT
Manual Override • • • •
Running Time (Motor) <75 seconds 150 seconds (variable) <75 seconds 150 seconds (variable)
Running Time (Fail-Safe) <20 seconds <20 seconds <20 seconds <20 seconds
3 ft, 18 GA appliance cable, 3 ft, 18 GA appliance cable, 3 ft, 18 GA appliance cable, 3 ft, 18 GA appliance cable,
Electrical Connection
½” conduit connector ½” conduit connector ½” conduit connector ½” conduit connector

2-Way
Body Close-Off
Size

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


Model # Cv Pressure Pressure
[mm]
Rating [psi]
G665C 65 2½” [65] 140 $3,395 $3,564
G680C 90 3” [80] 140 $3,719 $3,891
G6100C 170 4” [100] ANSI 125 140 $4,686 $4,800
G6125C 263 5” [125] 140 $6,551 $6,727

All prices are in US Dollars (USD)


G6150C 344 6” [150] 140 $7,232 $7,283
3-Way Mixing
G765 68 31 $2,870 $3,019
2½” [65]
G765 68 70 $3,687 $3,967
G780 90 ANSI 125 21 $3,135 $3,288
3” [80]
G780 90 48 $3,953 $4,262
G7100 190 4” [100] 26 $4,865 $4,923
3-Way Diverting
G765D 68 2½” [65] 140 $5,771 $5,940
G780D 90 3” [80] 140 $6,490 $6,642
G7100D 154 4” [100] ANSI 125 140 $7,469 $7,648
G7125D 195 5” [125] 140 $10,383 $10,723
GLOBE VALVES

G7150D 248 6” [150] 140 $13,371 $13,766

Prices do not reflect additional programming codes surcharge. See page 15-6 for linear actuator MFT codes. Note: All ”B” versions available as customizable ”X” versions.
Please see www.belimo.us for details.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

15-14
G6...C/G7...(D) Series Flanged Globe Valves with Electronic Fail-Safe Actuators
2-way and 3-way Valves with Bronze Trim – ANSI 125 Flanged

Valve Specifications
(G6) chilled, hot water, 60%
Service G6,G7 glycol, steam;
(G7) chilled, hot water, 60% glycol
(G6) equal percentage;
Flow Characteristic G6, G7
(G6LCS, G7) linear
Action G6 stem up - open A to AB
Action G7 stem up - open B to AB
Action G7D stem up - open AB to B
End Fitting 125 lb. flanged
Body cast iron - ASTM A126 Class B
Seat stainless steel
Stem stainless steel
Stem Packing NLP (no lip packing) (EPDM)
Plug bronze
Media Temp. Water G6 32°F to 300°F [0°C to 149°C]
Media Temp. Steam G6 32°F to 280°F [0°C to 138°C]
Media Temp. Water G7 32°F to 350°F [0°C to 176°C]
32°F to 300°F [0°C to 149°C]
Media Temp. Water G7D
6”only: 32°F to 150°F [0°C to 66°C]
Max Differential Pressure
25 psi [172 kPa]
(Water)
Max Differential Pressure
15 psi [103 kPa]
(Steam) G6
Leakage ANSI Class III
Max Inlet PSI (Water)
150 psi [1034 kPa] @ 250°F
G6, G7
Max Inlet Pressure
35 psi [241 kPa]
(Steam) G6

ACTUATOR PART # AVKB24-3 AVKB24-MFT 2*GKX24-MFT-X1


Control On/Off, Floating Point Modulating/MFT Modulating/MFT
Manual Override • • •
Running Time (Motor) 90 seconds 90 seconds (variable) 150 seconds (variable)
Running Time (Fail-Safe) 35 seconds 35 seconds 35 seconds
3 ft, 18 GA plenum rated cable with 3 ft, 18 GA plenum rated cable with 3 ft, 18 GA plenum rated cable with
Electrical Connection
½” conduit connector ½” conduit connector ½” conduit connector
2-Way
Body Close-Off
Size
Model # Cv Pressure Pressure
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

[mm]
Rating [psi]
G665C 65 2½” [65] 140 $3,230 $3,391
G680C 90 3” [80] 140 $3,573 $3,736
G6100C 170 4” [100] ANSI 125 140 $4,561 $4,721
G6125C 263 5” [125] 140 $6,115 $6,276
All prices are in US Dollars (USD)

G6150C 344 6” [150] 140 $7,083 $7,244


3-Way Mixing
G765 68 84 $3,064 $3,223
2½” [65]
G765 68 125 $6,241
G780 90 57 $3,129 $3,288
3” [80]
G780 90 ANSI 125 102 $6,535
G7100 190 4” [100] 56 $7,217
G7125 280 5” [125] 35 $9,415
G7150 340 6” [150] 24 $10,225
3-Way Diverting
G765D 68 2½” [65] 140 $5,780 $5,940
G780D 90 3” [80] 140 $6,483 $6,642
ANSI 125
GLOBE VALVES

G7100D 154 4” [100] 140 $7,268 $7,426


G7125D 195 5” [125] 140 $10,252 $10,412

Prices do not reflect additional programming codes surcharge. See page 15-6 for linear actuator MFT codes. Note: All ”B” versions available as customizable ”X” versions.
Please see www.belimo.us for details.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

15-15
G6...CS/G7...(D)S Series Flanged Globe Valves with Non Fail-Safe Actuators
2-way and 3-way Valves with Stainless Steel Trim – ANSI 125 Flanged

Valve Specifications
(G6) chilled, hot water, 60%
Service G6,G7 glycol, steam;
(G7) chilled, hot water, 60% glycol
(G6) equal percentage;
Flow Characteristic G6, G7
(G6LCS, G7) linear
Action G6 stem up - open A to AB
Action G7 stem up - open B to AB
Action G7D stem up - open AB to B
End Fitting 125 lb. flanged
Body cast iron - ASTM A126 Class B
Seat stainless steel
Stem stainless steel
Stem Packing NLP (no lip packing) (EPDM)
Plug stainless steel
Media Temp. Water G6 32°F to 350°F [0°C to 176°C]
Media Temp. Steam G6 32°F to 338°F [0°C to 170°C]
Media Temp. Water G7 32°F to 350°F [0°C to 176°C]
32°F to 300°F [0°C to 149°C]
Media Temp. Water G7D
6”only: 32°F to 150°F [0°C to 66°C]
Max Differential Pressure
50 psi [345 kPa]
(Water)
Max Differential Pressure
50 psi [345 kPa]
(Steam) G6
Leakage ANSI Class III
Max Inlet PSI (Water)
150 psi [1034 kPa] @ 250°F
G6, G7
Max Inlet Pressure
100 psi [690 kPa]
(Steam) G6

ACTUATOR PART # EVB24-3 EVB24-SR EVB24-MFT RVB24-3 RVB24-MFT


Control On/Off, Floating Point Modulating Modulating/MFT On/Off, Floating Point Modulating/MFT
Manual Override • • • • •
Running Time (Motor) 90 seconds 90 seconds 90 seconds (variable) 90 seconds 90 seconds (variable)
3 ft, 18 GA plenum rated 3 ft, 18 GA plenum rated 3 ft, 18 GA plenum rated 3 ft, 18 GA plenum rated 3 ft, 18 GA plenum rated
Electrical Connection cable with ½” conduit cable with ½” conduit cable with ½” conduit cable with ½” conduit cable with ½” conduit
connector connector connector connector connector
2-Way
Body Close-Off
Size
Model # Cv Pressure Pressure
[mm]
Rating [psi]

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


G665CS 65 2½” [65] 125 $4,276 $4,376 $4,436
G680CS 90 3” [80] 125 $4,982 $5,080 $5,140
G6100CS 170 4” [100] ANSI 125 125 $6,672 $6,769 $6,830
G6125CS 263 5” [125] 125 $8,856 $8,954 $9,014
G6150CS 344 6” [150] 125 $9,446 $9,543 $9,605

All prices are in US Dollars (USD)


3-Way Mixing
G765S 68 106 $3,853 $3,952 $4,010
2½” [65]
G765S 68 125 $4,370 $5,061
G780S 90 73 $4,557 $4,654 $4,715
3” [80]
G780S 90 125 $5,071 $5,757
ANSI 125
G7100S 190 40 $5,693 $5,791 $5,851
4” [100]
G7100S 190 75 $5,959 $6,646
G7125S 280 5” [125] 47 $8,932 $9,642
G7150S 340 6” [150] 32 $11,000 $11,640
3-Way Diverting
G765DS 68 2½” [65] 140 $8,407 $8,506 $8,566
G780DS 90 3” [80] 140 $9,553 $9,651 $9,712
140
GLOBE VALVES

G7100DS 154 4” [100] ANSI 125 $10,893 $10,991 $11,053


G7125DS 195 5” [125] 140 $15,734 $15,833 $15,894
G7150DS 248 6” [150] 140 $18,035 $18,133 $18,196

Prices do not reflect additional programming codes surcharge. See page 15-6 for linear actuator MFT codes. Note: All ”B” versions available as customizable ”X” versions.
Please see www.belimo.us for details.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

15-16
G6...CS/G7...(D)S Series Flanged Globe Valves with Spring Return Actuators
2-way and 3-way Valves with Stainless Steel Trim – ANSI 125 Flanged

Valve Specifications
(G6) chilled, hot water, 60%
Service G6,G7 glycol, steam;
(G7) chilled, hot water, 60% glycol
(G6) equal percentage;
Flow Characteristic G6, G7
(G6LCS, G7) linear Visit www.belimo.us for additional Spring Return options.
Action G6 stem up - open A to AB
Action G7 stem up - open B to AB
Action G7D stem up - open AB to B
End Fitting 125 lb. flanged
Body cast iron - ASTM A126 Class B
Seat stainless steel
Stem stainless steel
Stem Packing NLP (no lip packing) (EPDM)
Plug stainless steel
Media Temp. Water G6 32°F to 350°F [0°C to 176°C]
Media Temp. Steam G6 32°F to 338°F [0°C to 170°C]
Media Temp. Water G7 32°F to 350°F [0°C to 176°C]
32°F to 300°F [0°C to 149°C]
Media Temp. Water G7D
6”only: 32°F to 150°F [0°C to 66°C]
Max Differential Pressure
50 psi [345 kPa]
(Water)
Max Differential Pressure
50 psi [345 kPa]
(Steam) G6
Leakage ANSI Class III
Max Inlet PSI (Water)
150 psi [1034 kPa] @ 250°F
G6, G7
Max Inlet Pressure
100 psi [690 kPa]
(Steam) G6

ACTUATOR PART # AFBUP-X1 AFX24-MFT-X1 2*AFBUP-X1 2*AFX24-MFT-X1


Control On/Off Modulating/MFT On/Off Modulating/MFT
Manual Override • • • •
Running Time (Motor) <75 seconds 150 seconds (variable) <75 seconds 150 seconds (variable)
Running Time (Fail-Safe) <20 seconds <20 seconds <20 seconds <20 seconds

3 ft, 18 GA appliance cable, ½” 3 ft, 18 GA appliance cable, ½” 3 ft, 18 GA appliance cable, ½” 3 ft, 18 GA appliance cable, ½”
Electrical Connection
conduit connector conduit connector conduit connector conduit connector

2-Way
Body Close-Off
Size
Model # Cv Pressure Pressure
[mm]
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

Rating [psi]
G665CS 65 2½” [65] 125 $4,671 $4,816
G680CS 90 3” [80] 125 $5,375 $5,520
G6100CS 170 4” [100] ANSI 125 125 $7,433 $7,181
G6125CS 263 5” [125] 125 $9,831 $9,729
All prices are in US Dollars (USD)

G6150CS 344 6” [150] 125 $10,289 $10,036


3-Way Mixing
G765S 68 31 $3,804 $4,009
2½” [65]
G765S 68 70 $4,576 $5,106
G780S 90 ANSI 125 21 $4,480 $4,700
3” [80]
G780S 90 48 $5,281 $5,687
G7100S 190 4” [100] 26 $6,654 $6,626
3-Way Diverting
G765DS 68 2½” [65] 140 $8,354 $8,559
G780DS 90 3” [80] 140 $9,506 $9,710
G7100DS 154 4” [100] ANSI 125 140 $11,046 $11,252
G7125DS 195 5” [125] 140 $16,196 $16,598
G7150DS 248 6” [150] 140 $18,794 $19,199
GLOBE VALVES

Prices do not reflect additional programming codes surcharge. See page 15-6 for linear actuator MFT codes. Note: All ”B” versions available as customizable ”X” versions.
Please see www.belimo.us for details.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

15-17
G6...CS/G7...(D)S Series Flanged Globe Valves with Electronic Fail-Safe Actuators
2-way and 3-way Valves with Stainless Steel Trim – ANSI 125 Flanged

Valve Specifications
(G6) chilled, hot water, 60%
Service G6,G7 glycol, steam;
(G7) chilled, hot water, 60% glycol
(G6) equal percentage;
Flow Characteristic G6, G7
(G6LCS, G7) linear
Action G6 stem up - open A to AB
Action G7 stem up - open B to AB
Action G7D stem up - open AB to B
End Fitting 125 lb. flanged
Body cast iron - ASTM A126 Class B
Seat stainless steel
Stem stainless steel
Stem Packing NLP (no lip packing) (EPDM)
Plug stainless steel
Media Temp. Water G6 32°F to 350°F [0°C to 176°C]
Media Temp. Steam G6 32°F to 338°F [0°C to 170°C]
Media Temp. Water G7 32°F to 350°F [0°C to 176°C]
32°F to 300°F [0°C to 149°C]
Media Temp. Water G7D
6”only: 32°F to 150°F [0°C to 66°C]
Max Differential Pressure
50 psi [345 kPa]
(Water)
Max Differential Pressure
50 psi [345 kPa]
(Steam) G6
Leakage ANSI Class III
Max Inlet PSI (Water)
150 psi [1034 kPa] @ 250°F
G6, G7
Max Inlet Pressure
100 psi [690 kPa]
(Steam) G6

ACTUATOR PART # AVKB24-3 AVKB24-MFT 2*GKX24-MFT-X1


Control On/Off, Floating Point Modulating/MFT Modulating/MFT
Manual Override • • •
Running Time (Motor) 90 seconds 90 seconds (variable) 150 seconds (variable)
Running Time (Fail-Safe) 35 seconds 35 seconds 35 seconds
3 ft, 18 GA plenum rated cable with 3 ft, 18 GA plenum rated cable with 3 ft, 18 GA plenum rated cable with
Electrical Connection
½” conduit connector ½” conduit connector ½” conduit connector
2-Way
Body Close-Off
Size
Model # Cv Pressure Pressure
[mm]
Rating [psi]

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


G665CS 65 2½” [65] 125 $4,465 $4,564
G680CS 90 3” [80] 125 $5,260 $5,358
G6100CS 170 4” [100] ANSI 125 125 $6,874 $6,973
G6125CS 263 5” [125] 125 $9,631 $9,729
G6150CS 344 6” [150] 125 $9,645 $9,744

All prices are in US Dollars (USD)


3-Way Mixing
G765S 68 84 $3,851 $4,009
2½” [65]
G765S 68 125 $7,379
G780S 90 57 $4,540 $4,700
3” [80]
G780S 90 ANSI 125 102 $7,958
G7100S 190 4” [100] 56 $8,897
G7125S 280 5” [125] 35 $11,905
G7150S 340 6” [150] 24 $13,912
3-Way Diverting
G765DS 68 2½” [65] 140 $8,399 $8,559
G780DS 90 3” [80] ANSI 125 140 $9,552 $9,710
G7100DS 154 4” [100] 140 $10,764 $10,923
GLOBE VALVES

Prices do not reflect additional programming codes surcharge. See page 15-6 for linear actuator MFT codes. Note: All ”B” versions available as customizable ”X” versions.
Please see www.belimo.us for details.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

15-18
G6…LCS Series Flanged Globe Valves with Non Fail-Safe Actuators
2-way Linear Valve with Stainless Steel Trim– ANSI 125 Flanged

Valve Specifications
chilled or hot water, up to 60%
Service
glycol, steam
Flow Characteristic linear
Action stem up - open A to AB
End Fitting 125 lb. flanged
Body cast iron - ASTM A126 Class B
Seat stainless steel
Stem stainless steel
Stem Packing NLP (no lip packing) (EPDM)
Plug stainless steel
Media Temperature Range
32°F to 350°F [0°C to 176°C]
(Water)
Media Temperature Range
32°F to 338°F [0°C to 170°C]
(Steam)
Max Differential Pressure
50 psi [345 kPa]
(Water)
Max Differential Pressure
50 psi [345 kPa]
(Steam)
Leakage ANSI Class III
Max Inlet Pressure (Water) 150 psi [1034 kPa] @ 250°F
Max Inlet Pressure
100 psi [690 kPa]
(Steam)

ACTUATOR PART # EVB24-3 EVB24-SR EVB24-MFT


Control On/Off, Floating Point Modulating Modulating/MFT
Manual Override • • •
Running Time (Motor) 90 seconds 90 seconds 90 seconds (variable)
3 ft, 18 GA plenum rated cable with 3 ft, 18 GA plenum rated cable with 3 ft, 18 GA plenum rated cable with
Electrical Connection
½” conduit connector ½” conduit connector ½” conduit connector
2-Way
Body Close-Off
Size
Model # Cv Pressure Pressure
[mm]
Rating [psi]
G665LCS 65 2½” [65] 125 $4,326 $4,424 $4,486
G680LCS 90 3” [80] 125 $5,092 $5,190 $5,251
G6100LCS 170 4” [100] ANSI 125 125 $6,781 $6,879 $6,940
G6125LCS 263 5” [125] 125 $8,684 $8,782 $8,844
G6150LCS 344 6” [150] 125 $9,386 $9,484 $9,543
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

Prices do not reflect additional programming codes surcharge. See page 15-6 for linear actuator MFT codes. Note: All ”B” versions available as customizable ”X” versions.
Please see www.belimo.us for details.
All prices are in US Dollars (USD)

GLOBE VALVES

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

15-19
G6...LCS Series Flanged Globe Valves with Spring Return Actuators
2-way Linear Valve with Stainless Steel Trim – ANSI 125 Flanged

Valve Specifications
chilled or hot water, up to 60%
Service
glycol, steam
Flow Characteristic linear
Action stem up - open A to AB
End Fitting 125 lb. flanged Visit www.belimo.us for additional Spring Return options.
Body cast iron - ASTM A126 Class B
Seat stainless steel
Stem stainless steel
Stem Packing NLP (no lip packing) (EPDM)
Plug stainless steel
Media Temperature Range
32°F to 350°F [0°C to 176°C]
(Water)
Media Temperature Range
32°F to 338°F [0°C to 170°C]
(Steam)
Max Differential Pressure
50 psi [345 kPa]
(Water)
Max Differential Pressure
50 psi [345 kPa]
(Steam)
Leakage ANSI Class III
Max Inlet Pressure (Water) 150 psi [1034 kPa] @ 250°F
Max Inlet Pressure
100 psi [690 kPa]
(Steam)

ACTUATOR PART # AFBUP-X1 AFX24-MFT-X1 2*AFBUP-X1 2*AFX24-MFT-X1


Control On/Off Modulating/MFT On/Off Modulating/MFT
Manual Override • • • •
Running Time (Motor) <75 seconds 150 seconds (variable) <75 seconds 150 seconds (variable)
Running Time (Fail-Safe) <20 seconds <20 seconds <20 seconds <20 seconds
3 ft, 18 GA appliance cable, 3 ft, 18 GA appliance cable, 3 ft, 18 GA appliance cable, 3 ft, 18 GA appliance cable,
Electrical Connection
½” conduit connector ½” conduit connector ½” conduit connector ½” conduit connector
2-Way
Body Close-Off
Size
Model # Cv Pressure Pressure
[mm]
Rating [psi]
G665LCS 65 2½” [65] 125 $4,671 $4,782
G680LCS 90 3” [80] 125 $5,375 $5,595
G6100LCS 170 4” [100] ANSI 125 125 $7,433 $7,181
G6125LCS 263 5” [125] 125 $9,831 $9,729

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


G6150LCS 344 6” [150] 125 $10,289 $10,036

Prices do not reflect additional programming codes surcharge. See page 15-6 for linear actuator MFT codes. Note: All ”B” versions available as customizable ”X” versions.
Please see www.belimo.us for details.

All prices are in US Dollars (USD)


GLOBE VALVES

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

15-20
G6...LCS Series Flanged Globe Valves with Electronic Fail-Safe Actuators
2-way Linear Valve with Stainless Steel Trim – ANSI 125 Flanged

Valve Specifications
chilled or hot water, up to 60%
Service
glycol, steam
Flow Characteristic linear
Action stem up - open A to AB
End Fitting 125 lb. flanged
Body cast iron - ASTM A126 Class B
Seat stainless steel
Stem stainless steel
Stem Packing NLP (no lip packing) (EPDM)
Plug stainless steel
Media Temperature Range
32°F to 350°F [0°C to 176°C]
(Water)
Media Temperature Range
32°F to 338°F [0°C to 170°C]
(Steam)
Max Differential Pressure
50 psi [345 kPa]
(Water)
Max Differential Pressure
50 psi [345 kPa]
(Steam)
Leakage ANSI Class III
Max Inlet Pressure (Water) 150 psi [1034 kPa] @ 250°F
Max Inlet Pressure
100 psi [690 kPa]
(Steam)

ACTUATOR PART # AVKB24-3 AVKB24-MFT


Control On/Off, Floating Point Modulating/MFT
Manual Override • •
Running Time (Motor) 90 seconds 90 seconds (variable)
Running Time (Fail-Safe) 35 seconds 35 seconds
Electrical Connection 3 ft, 18 GA plenum rated cable with ½” conduit connector 3 ft, 18 GA plenum rated cable with ½” conduit connector
2-Way
Body Close-Off
Size
Model # Cv Pressure Pressure
[mm]
Rating [psi]
G665LCS 65 2½” [65] 125 $4,465 $4,564
G680LCS 90 3” [80] 125 $5,122 $5,222
G6100LCS 170 4” [100] ANSI 125 125 $6,874 $6,973
G6125LCS 263 5” [125] 125 $9,631 $9,729
G6150LCS 344 6” [150] 125 $9,645 $9,744
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

Prices do not reflect additional programming codes surcharge. See page 15-6 for linear actuator MFT codes. Note: All ”B” versions available as customizable ”X” versions.
Please see www.belimo.us for details.
All prices are in US Dollars (USD)

GLOBE VALVES

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

15-21
G6…C-250/G7…-250 Series Flanged Globe Valves with Non Fail-Safe Actuators
2-way and 3-way Valves with Bronze Trim – ANSI 250 Flanged

Valve Specifications
(G6) chilled, hot water, 60%
Service G6,G7 glycol, steam;
(G7) chilled, hot water, 60% glycol
(G6) equal percentage;
Flow Characteristic G6, G7
(G6LCS, G7) linear
Action G6 stem up - open A to AB
Action G7 stem up - open B to AB
End Fitting 250 lb. flanged
Body cast iron - ASTM A126 Class B
Seat stainless steel
Stem stainless steel
Stem Packing NLP (no lip packing) (EPDM)
Plug bronze
Media Temp. Water G6 32°F to 300°F [0°C to 149°C]
Media Temp. Steam G6 32°F to 280°F [0°C to 138°C]
Media Temp. Water G7 32°F to 350°F [0°C to 176°C]
Max Differential Pressure
25 psi [172 kPa]
(Water)
Max Differential Pressure
15 psi [103 kPa]
(Steam) G6
Leakage ANSI Class III
(G6) 280 psi [1930 kPa] @ 350°F
Max Inlet PSI (Water)
(G7) 310 psi [2137 kPa] @ 300°F
Max Inlet Pressure
35 psi [241 kPa]
(Steam) G6

ACTUATOR PART # EVB24-3 EVB24-SR EVB24-MFT RVB24-3 RVB24-MFT


Control On/Off, Floating Point Modulating Modulating/MFT On/Off, Floating Point Modulating/MFT
Manual Override • • • • •
Running Time (Motor) 90 seconds 90 seconds 90 seconds (variable) 90 seconds 90 seconds (variable)

3 ft, 18 GA plenum rated 3 ft, 18 GA plenum rated 3 ft, 18 GA plenum rated 3 ft, 18 GA plenum rated 3 ft, 18 GA plenum rated
Electrical Connection cable with ½” conduit cable with ½” conduit cable with ½” conduit cable with ½” conduit cable with ½” conduit
connector connector connector connector connector

2-Way
Body Close-Off
Size
Model # Cv Pressure Pressure
[mm]
Rating [psi]
G665C-250 65 2½” [65] 310 $2,999 $3,098 $3,157
G680C-250 90 3” [80] 310 $3,506 $3,605 $3,665

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


G6100C-250 170 4” [100] ANSI 250 310 $4,619 $4,715 $4,778
G6125C-250 263 5” [125] 310 $6,551 $6,648 $6,710
G6150C-250 344 6” [150] 310 $6,846 $6,943 $7,003
3-Way Mixing
G765-250 68 106 $3,976 $4,075 $4,136

All prices are in US Dollars (USD)


2½” [65]
G765-250 68 198 $5,426 $5,583
G780-250 90 73 $4,532 $4,630 $4,691
3” [80]
G780-250 90 136 $5,517 $5,675
ANSI 250
G7100-250 190 40 $6,708 $6,806 $6,866
4” [100]
G7100-250 190 75 $7,372 $7,531
G7125-250 280 5” [125] 47 $10,911 $11,071
G7150-250 340 6” [150] 32 $12,594 $12,751

Prices do not reflect additional programming codes surcharge. See page 15-6 for linear actuator MFT codes. Note: All ”B” versions available as customizable ”X” versions.
Please see www.belimo.us for details.
GLOBE VALVES

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

15-22
G6…C-250/G7…-250 Series Flanged Globe Valves with Spring Return Actuators
2-way and 3-way Valve with Bronze Trim – ANSI 250 Flanged

Valve Specifications
(G6) chilled, hot water, 60%
Service G6,G7 glycol, steam;
(G7) chilled, hot water, 60% glycol
(G6) equal percentage;
Flow Characteristic G6, G7
(G6LCS, G7) linear Visit www.belimo.us for additional Spring Return options.
Action G6 stem up - open A to AB
Action G7 stem up - open B to AB
End Fitting 250 lb. flanged
Body cast iron - ASTM A126 Class B
Seat stainless steel
Stem stainless steel
Stem Packing NLP (no lip packing) (EPDM)
Plug bronze
Media Temp. Water G6 32°F to 300°F [0°C to 149°C]
Media Temp. Steam G6 32°F to 280°F [0°C to 138°C]
Media Temp. Water G7 32°F to 350°F [0°C to 176°C]
Max Differential Pressure
25 psi [172 kPa]
(Water)
Max Differential Pressure
15 psi [103 kPa]
(Steam) G6
Leakage ANSI Class III
(G6) 280 psi [1930 kPa] @ 350°F
Max Inlet PSI (Water)
(G7) 310 psi [2137 kPa] @ 300°F
Max Inlet Pressure
35 psi (241 kPa)
(Steam) G6

ACTUATOR PART # AFBUP-X1 AFX24-MFT-X1 2*AFBUP-X1 2*AFX24-MFT-X1


Control On/Off Modulating/MFT On/Off Modulating/MFT
Manual Override • • • •
Running Time (Motor) <75 seconds 150 seconds (variable) <75 seconds 150 seconds (variable)
Running Time (Fail-Safe) <20 seconds <20 seconds <20 seconds <20 seconds
3 ft, 18 GA appliance cable, 3 ft, 18 GA appliance cable, 3 ft, 18 GA appliance cable, ½” 3 ft, 18 GA appliance cable,
Electrical Connection
½” conduit connector ½” conduit connector conduit connector ½” conduit connector
2-Way
Body Close-Off
Size
Model # Cv Pressure Pressure
[mm]
Rating [psi]
G665C-250 65 2½” [65] 232 $3,466 $3,618
G680C-250 90 3” [80] 181 $3,873 $3,831
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

G680C-250 90 3” [80] 310 $4,576 $4,907


ANSI 250
G6100C-250 170 4” [100] 310 $5,362 $5,665
G6125C-250 263 5” [125] 241 $6,567 $6,868
G6150C-250 344 6” [150] 182 $8,926 $9,227
3-Way Mixing
All prices are in US Dollars (USD)

G765-250 68 31 $3,886 $3,978


2½” [65]
G765-250 68 70 $4,725 $4,975
G780-250 90 ANSI 250 21 $4,466 $4,665
3” [80]
G780-250 90 48 $5,275 $5,687
G7100-250 190 4” [100] 26 $6,280

Prices do not reflect additional programming codes surcharge. See page 15-6 for linear actuator MFT codes. Note: All ”B” versions available as customizable ”X” versions.
Please see www.belimo.us for details.

GLOBE VALVES

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

15-23
G6…C-250/G7…-250 Series Flanged Globe Valves
with Electronic Fail-Safe Actuators
2-way and 3-way Valves with Bronze Trim – ANSI 250 Flanged
Valve Specifications
(G6) chilled, hot water, 60%
Service G6,G7 glycol, steam;
(G7) chilled, hot water, 60% glycol
(G6) equal percentage;
Flow Characteristic G6, G7
(G6LCS, G7) linear
Action G6 stem up - open A to AB
Action G7 stem up - open B to AB
End Fitting 250 lb. flanged
Body cast iron - ASTM A126 Class B
Seat stainless steel
Stem stainless steel
Stem Packing NLP (no lip packing) (EPDM)
Plug bronze
Media Temp. Water G6 32°F to 300°F [0°C to 149°C]
Media Temp. Steam G6 32°F to 280°F [0°C to 138°C]
Media Temp. Water G7 32°F to 350°F [0°C to 176°C]
Max Differential Pressure
25 psi [172 kPa]
(Water)
Max Differential Pressure
15 psi [103 kPa]
(Steam) G6
Leakage ANSI Class III
(G6) 280 psi [1930 kPa] @ 350°F
Max Inlet PSI (Water)
(G7) 310 psi [2137 kPa] @ 300°F
Max Inlet Pressure
35 psi [241 kPa]
(Steam) G6

ACTUATOR PART # AVKB24-3 AVKB24-MFT 2*GKX24-MFT-X1


Control On/Off, Floating Point Modulating/MFT Modulating/MFT
Manual Override • • •
Running Time (Motor) 90 seconds 90 seconds (variable) 150 seconds (variable)
Running Time (Fail-Safe) 35 seconds 35 seconds 35 seconds
3 ft, 18 GA plenum rated cable with 3 ft, 18 GA plenum rated cable with 3 ft, 18 GA plenum rated cable with
Electrical Connection
½” conduit connector ½” conduit connector ½” conduit connector
2-Way
Body Close-Off
Size
Model # Cv Pressure Pressure
[mm]
Rating [psi]
G665C-250 65 2½” [65] 310 $3,228 $3,388
G680C-250 90 3” [80] 310 $3,650 $3,812

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


G6100C-250 170 4” [100] ANSI 250 310 $5,340 $5,501
G6125C-250 263 5” [125] 300 $6,709 $6,868
G6150C-250 344 6” [150] 232 $8,798 $8,959
3-Way Mixing
G765-250 68 84 $4,089 $4,249 $7,250
2½” [65]

All prices are in US Dollars (USD)


G765-250 68 149 $4,089 $4,249 $7,250
G780-250 90 ANSI 250 57 $4,503 $4,665 $7,958
3” [80]
G780-250 90 102 $4,503 $4,665 $7,958
G7100-250 190 4” [100] 56 $9,784

Prices do not reflect additional programming codes surcharge. See page 15-6 for linear actuator MFT codes. Note: All ”B” versions available as customizable ”X” versions.
Please see www.belimo.us for details.
GLOBE VALVES

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

15-24
G6…CS-250/G7…S(DS)-250 Series Flanged Globe Valves
with Non Fail-Safe Actuators
2-way and 3-way Valves with Stainless Steel Trim – ANSI 250 Flanged
Valve Specifications
(G6) chilled, hot water, 60%
Service G6,G7 glycol, steam;
(G7) chilled, hot water, 60% glycol
(G6) equal percentage;
Flow Characteristic G6, G7
(G6LCS, G7) linear
Action G6 stem up - open A to AB
Action G7 stem up - open B to AB
Action G7D stem up - open AB to B
End Fitting 250 lb. flanged
Body cast iron - ASTM A126 Class B
Seat stainless steel
Stem stainless steel
Stem Packing NLP (no lip packing) (EPDM)
Plug stainless steel
Media Temp. Water G6 32°F to 350°F [0°C to 176°C]
Media Temp. Steam G6 32°F to 338°F [0°C to 170°C]
Media Temp. Water G7 32°F to 350°F [0°C to 176°C]
32°F to 300°F [0°C to 149°C]
Media Temp. Water G7D
6”only: 32°F to 150°F [0°C to 66°C]
Max Differential Pressure
50 psi [345 kPa]
(Water)
Max Differential Pressure
50 psi [345 kPa]
(Steam) G6
Leakage ANSI Class III
(G6) 280 psi [1930 kPa] @ 350°F
Max Inlet PSI (Water)
(G7) 310 psi [2137 kPa] @ 300°F
Max Inlet Pressure
100 psi [690 kPa]
(Steam) G6

ACTUATOR PART # EVB24-3 EVB24-SR EVB24-MFT RVB24-3 RVB24-MFT


Control On/Off, Floating Point Modulating Modulating/MFT On/Off, Floating Point Modulating/MFT
Manual Override • • • • •
Running Time (Motor) 90 seconds 90 seconds 90 seconds (variable) 90 seconds 90 seconds (variable)
3 ft, 18 GA plenum rated 3 ft, 18 GA plenum rated 3 ft, 18 GA plenum rated 3 ft, 18 GA plenum rated 3 ft, 18 GA plenum rated
Electrical Connection cable with ½” conduit cable with ½” conduit cable with ½” conduit cable with ½” conduit cable with ½” conduit
connector connector connector connector connector
2-Way
Body Close-Off
Size
Model # Cv Pressure Pressure
[mm]
Rating [psi]
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

G665CS-250 65 2½” [65] 280 $4,795 $4,893 $4,956


G680CS-250 90 3” [80] 280 $5,134 $5,233 $5,293
G6100CS-250 170 4” [100] ANSI 250 280 $6,997 $7,096 $7,156
G6125CS-250 263 5” [125] 280 $9,810 $9,909 $9,969
G6150CS-250 344 6” [150] 280 $12,379 $12,476 $12,539
All prices are in US Dollars (USD)

3-Way Mixing
G765S-250 68 106 $4,245 $4,343 $4,402
2½” [65]
G765S-250 68 198 $5,260 $5,420
G780S-250 90 73 $4,866 $4,965 $5,024
3” [80]
G780S-250 90 136 $5,872 $6,031
ANSI 250
G7100S-250 190 40 $7,869 $7,965 $8,028
4” [100]
G7100S-250 190 75 $8,517 $8,676
G7125S-250 280 5” [125] 47 $12,359 $12,520
G7150S-250 340 6” [150] 32 $12,842 $13,000
3-Way Diverting
G765DS-250 68 2½” [65] 310 $9,888 $9,986 $10,048
G780DS-250 90 3” [80] 310 $11,237 $11,335 $11,397
GLOBE VALVES

G7100DS-250 154 4” [100] ANSI 250 310 $12,723 $12,820 $12,882


G7125DS-250 195 5” [125] 310 $18,334 $18,434 $18,494
G7150DS-250 248 6” [150] 310 $22,450 $22,547 $22,609

Prices do not reflect additional programming codes surcharge. See page 15-6 for linear actuator MFT codes. Note: All ”B” versions available as customizable ”X” versions.
Please see www.belimo.us for details.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

15-25
G6…CS-250/G7…S(DS)-250 Series Flanged Globe Valves
with Spring Return Actuators
2-way and 3-way Valves with Stainless Steel Trim – ANSI 250 Flanged
Valve Specifications
(G6) chilled, hot water, 60%
Service G6,G7 glycol, steam;
(G7) chilled, hot water, 60% glycol
(G6) equal percentage;
Flow Characteristic G6, G7
(G6LCS, G7) linear Visit www.belimo.us for additional Spring Return options.
Action G6 stem up - open A to AB
Action G7 stem up - open B to AB
Action G7D stem up - open AB to B
End Fitting 250 lb. flanged
Body cast iron - ASTM A126 Class B
Seat stainless steel
Stem stainless steel
Stem Packing NLP (no lip packing) (EPDM)
Plug stainless steel
Media Temp. Water G6 32°F to 350°F [0°C to 176°C]
Media Temp. Steam G6 32°F to 338°F [0°C to 170°C]
Media Temp. Water G7 32°F to 350°F [0°C to 176°C]
32°F to 300°F [0°C to 149°C]
Media Temp. Water G7D
6”only: 32°F to 150°F [0°C to 66°C]
Max Differential Pressure
50 psi [345 kPa]
(Water)
Max Differential Pressure
50 psi [345 kPa]
(Steam) G6
Leakage ANSI Class III
(G6) 280 psi [1930 kPa] @ 350°F
Max Inlet PSI (Water)
(G7) 310 psi [2137 kPa] @ 300°F
Max Inlet Pressure
100 psi [690 kPa]
(Steam) G6

ACTUATOR PART # AFBUP-X1 AFX24-MFT-X1 2*AFBUP-X1 2*AFX24-MFT-X1


Control On/Off Modulating/MFT On/Off Modulating/MFT
Manual Override • • • •

Running Time (Motor) <75 seconds 150 seconds (variable) <75 seconds 150 seconds (variable)

Running Time (Fail-Safe) <20 seconds <20 seconds <20 seconds <20 seconds
3 ft, 18 GA appliance cable, 3 ft, 18 GA appliance cable, 3 ft, 18 GA appliance cable, 3 ft, 18 GA appliance cable,
Electrical Connection
½” conduit connector ½” conduit connector ½” conduit connector ½” conduit connector
2-Way
Body Close-Off
Size
Model # Cv Pressure Pressure

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


[mm]
Rating [psi]
G665CS-250 65 2½” [65] 232 $3,886 $4,625
ANSI 250
G680CS-250 90 3” [80] 181 $6,114 $6,288 $5,882 $6,293
3-Way Mixing
G765S-250 68 31 $4,156 $4,360

All prices are in US Dollars (USD)


2½” [65]
G765S-250 68 70 $4,936 $5,336
G780S-250 90 ANSI 250 21 $4,782 $4,700
3” [80]
G780S-250 90 48 $5,563 $5,687
G7100S-250 190 4” [100] 18 $6,626
3-Way Diverting
G765DS-250 68 2½” [65] 310 $9,840 $10,043
G780DS-250 90 3” [80] 310 $11,243 $11,429
G7100DS-250 154 4” [100] ANSI 250 310 $13,075 $13,290
G7125DS-250 195 5” [125] 310 $17,941 $18,347
G7150DS-250 248 6” [150] 310 $23,230 $23,636

Prices do not reflect additional programming codes surcharge. See page 15-6 for linear actuator MFT codes. Note: All ”B” versions available as customizable ”X” versions.
GLOBE VALVES

Please see www.belimo.us for details.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

15-26
G6…CS-250/G7…S(DS)-250 Series Flanged Globe Valves
with Electronic Fail-Safe Actuators
2-way and 3-way Valves with Stainless Steel Trim – ANSI 250 Flanged
Valve Specifications
(G6) chilled, hot water, 60%
Service G6,G7 glycol, steam;
(G7) chilled, hot water, 60% glycol
(G6) equal percentage;
Flow Characteristic G6, G7
(G6LCS, G7) linear
Action G6 stem up - open A to AB
Action G7 stem up - open B to AB
Action G7D stem up - open AB to B
End Fitting 250 lb. flanged
Body cast iron - ASTM A126 Class B
Seat stainless steel
Stem stainless steel
Stem Packing NLP (no lip packing) (EPDM)
Plug stainless steel
Media Temp. Water G6 32°F to 350°F [0°C to 176°C]
Media Temp. Steam G6 32°F to 338°F [0°C to 170°C]
Media Temp. Water G7 32°F to 350°F [0°C to 176°C]
32°F to 300°F [0°C to 149°C]
Media Temp. Water G7D
6”only: 32°F to 150°F [0°C to 66°C]
Max Differential Pressure
50 psi [345 kPa]
(Water)
Max Differential Pressure
50 psi [345 kPa]
(Steam) G6
Leakage ANSI Class III
(G6) 280 psi [1930 kPa] @ 350°F
Max Inlet PSI (Water)
(G7) 310 psi [2137 kPa] @ 300°F
Max Inlet Pressure
100 psi [690 kPa]
(Steam) G6

ACTUATOR PART # AVKB24-3 AVKB24-MFT 2*GKX24-MFT-X1


Control On/Off, Floating Point Modulating/MFT Modulating/MFT
Manual Override • • •
Running Time (Motor) 90 seconds 90 seconds (variable) 150 seconds (variable)
Running Time (Fail-Safe) 35 seconds 35 seconds 35 seconds
3 ft, 18 GA plenum rated cable with 3 ft, 18 GA plenum rated cable with 3 ft, 18 GA plenum rated cable with
Electrical Connection
½” conduit connector ½” conduit connector ½” conduit connector

2-Way
Body Close-Off
Size
Model # Cv Pressure Pressure
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

[mm]
Rating [psi]
G665CS-250 65 2½” [65] 280 $5,253 $5,412
G680CS-250 90 3” [80] 280 $6,104 $6,042
G6100CS-250 170 4” [100] 280 $7,651 $7,811
ANSI 250
G6125CS-250 263 5” [125] 280 $10,528 $10,688
All prices are in US Dollars (USD)

G6150CS-250 344 280 $13,959 $14,118


6” [150]
G6150CS-250 344 280 $14,977
3-Way Mixing
G765S-250 68 84 $4,201 $4,360
2½” [65]
G765S-250 68 149 $7,246
G780S-250 90 ANSI 250 57 $4,540 $4,700
3” [80]
G780S-250 90 102 $7,822
G7100S-250 190 4” [100] 41 $10,459
3-Way Diverting
G765DS-250 68 2½” [65] 310 $9,884 $10,043
G780DS-250 90 3” [80] ANSI 250 310 $11,267 $11,429
G7100DS-250 154 4” [100] 310 $12,742 $12,903
GLOBE VALVES

Prices do not reflect additional programming codes surcharge. See page 15-6 for linear actuator MFT codes. Note: All ”B” versions available as customizable ”X” versions.
Please see www.belimo.us for details.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

15-27
Greater Force
and Flexibility

Belimo Globe Valves


Belimo’s full range of NPT pressure compensated globe valves offer ANSI Class VI
leakage and 100:1 rangeability and provide accurate modulation at low flow. Select
models incorporate Multi-Function Technology™ (MFT) allowing for easy and flexible field
configuration (pulse width modulation, analog DC proportional control, floating point or
on/off control.)

Discover the advantages


www.belimo.us
BUTTERFLY VALVES, PIPE PACKAGES,
VALVE ACCESSORIES
16
BUTTERFLY VALVES
HD, HDU, L, LU, VIC AND
SHP SERIES
High Performance for a Wide
Range of Applications
• Full range of actuators with NEMA 2 or
4X rated enclosures providing application
flexibility and reliability.
• Innovative seat and disc design provides
zero percent leakage capability at each
valve’s rated temperature/pressure while
maintaining a low seating torque.
• Stainless steel disc and shaft on HD, L
and SHP series are standard for superior
durability and long lasting operation.

Henry Espinal, Assembler II, Butterfly Valves


Butterfly Valve Nomenclature

F6 200 L +PRB UP -3 -T -200


Valve Valve Size Trim Material Actuator Type Power Supply Control
F6 = 2-way 50 = 2” HD = Stainless Disc, Non Fail-Safe -24 = 24 VAC/DC -3-X1 = On/Off, -S = Built-in -200 = 8”
F7 = 3-way 65 = 2½” Ductile Iron Body, EPDM ARB, ARX -110 = 110/120 VAC Floating Point Auxiliary Switch -250 = 10”
Liner, 0% Leakage to 200 AMB, AMX -SR = Modulating N4 = NEMA 4/4X
80 = 3” psi (2” to 6”), 150 psi (14”+) GMB, GMX
-120 = 120 VAC
100 = 4” -230 = 230 VAC Input = 2-10 VDC -T = Terminal
L = Stainless Disc, GRB, GRX Block
125 = 5” Ductile Iron Body, UP = 24-240 VAC -MFT or -MFT-X1 =
GR/GM... N4 Multi-Function
150 = 6” EPDM Liner, 0% Leakage to DRB, DRX or 24-125 VDC
200 psi (8” to 12”) Technology
200 = 8” DR... N4
HDU/LU = Stainless Disc, PRB, PRX
250 = 10”
Ductile Iron Body, SY
300 = 12” EPDM Liner, 0% Leakage to
BUTTERFLY VALVES, PIPE PACKAGES,

Fail-Safe
350 = 14” 50 psi (3” to 10”)
Electronic
400 = 16” VIC = Ductile Iron Grooved
GKB, GKX
End Body, Nickel Coated
VALVE ACCESSORIES

450 = 18” DKRB, DKRX


Ductile Iron Disc, 0%
500 = 20” DKR...N4
Leakage up to 200 psi
600 = 24” PKRX
-150SHP = ANSI Class 150,
Spring Return
Stainless Disc, Steel Body,
RPTFE Seat, 0% Leakage up AFB, AFX
to 285 psi AFRB, AFRX
-300SHP = ANSI Class 300,
Stainless Disc, Steel Body,
“X” models are customizable.
RPTFE Seat, 0% Leakage up Refer to page 16-10 for programming options.
to 600 psi

Ordering Example

3 For MFT orders only - select programming code (consult factory)


1 Choose the valve actuator combination. Programming codes, refer to page 16-10.

F6200L+PRBUP-3-T-200 NO Tagging (if needed)


4
2 Specify preference or configuration.
Does order
require
tagging?
2-way Configuration Set-Up 3-way Configuration
Set Up Required No Set Up Required
2 Pos.
2 Pos.

Field Logic Determines Normal Position Field Logic Determines Normal Position Tagging:
[see pages 16-4, 16-5]
Specify Flow Pattern

Valves may be
Non Fail-Safe
Non Fail-Safe

(Normally Closed) Master (Actuated) Valve


NC
(Normally Closed)
tagged per customer
0.5 VDC/2 VDC/4mA = Closed NC
specification. ($12.00
Modulating
Modulating

0.5 VDC/2 VDC/4mA = Closed

Master (Actuated) Valve


per tag)
NO (Normally Open)
0.5 VDC/2 VDC/4mA = Open NO (Normally Open) Example:
0.5 VDC/2 VDC/4mA = Open Chiller 1
3rd Floor East
NO/FO (Normally Open/Fail Open) (Normally Open/Fail Open)
Field Logic Determines Normal Position NO/FO Field Logic Determines Normal Position
Master (Actuated) Valve Fails OPEN
Part number for
2 Pos.

Valve Fails OPEN


2 Pos.

Specify Flow Pattern [see pages 16-4, 16-5]

(Normally Closed/Fail Closed) (Normally Closed/Fail Closed) tagging: 99981-00101


NC/FC
Field Logic Determines Normal Position NC/FC Field Logic Determines Normal Position
Valve Fails CLOSED Master (Actuated) Valve Fails CLOSED
NO/FC (Normally Open/Fail Closed) (Normally Open/Fail Open)
0.5 VDC/2 VDC/4mA = Open NO/FO 0.5 VDC/2 VDC/4mA = Master Valve Open
Fail-Safe

Fail-Safe

Master (Actuated) Valve Fails OPEN


Valve Fails CLOSED
(Normally Closed/Fail Open) (Normally Open/Fail Closed)
5 Complete Ordering Example: F6200L+PRBUP-3-T-200
NC/FO
0.5 VDC/2 VDC/4mA = Closed NO/FC 0.5 VDC/2 VDC/4mA = Maser Valve Open Configuration: NO
Modulating

Modulating

Valve Fails OPEN Master (Actuated) Valve Fails CLOSED


(Normally Open/Fail Open) (Normally Closed/Fail Open) Programming: X10
NO/FO 0.5 VDC/2 VDC/4mA = Master Valve Open NC/FO 0.5 VDC/2 VDC/4mA = Master Valve Closed
Master (Actuated) Valve Fails OPEN Master (Actuated) Valve Fails OPEN
(Normally Closed/Fail Closed) (Normally Closed/Fail Closed)
NC/FC 0.5 VDC/2 VDC/4mA = Master Valve Closed NC/FC 0.5 VDC/2 VDC/4mA = Master Valve Closed
Master (Actuated) Valve Fails CLOSED Master (Actuated) Valve Fails CLOSED
Resilient Seat Butterfly Valve Product Range

2-way Suitable Actuators


Fail-Safe
Valve
Type Non Fail-Safe Spring
Nominal Size Electronic
Return
Cv Cv DN HDU
IN 2-way L HD HD L HD
90° 60° [mm] LU
115 44 2 50 F650

AF Series
AR

GR Series
196 75 2½ 65 F665

GKR
GR
AR

302 116 3 80 F680


600 230 4 100 F6100 Mode of Operation

PKR Series
PR Series

DKR
GR

DR
Butterfly valves are capable of handling higher flow rates
1022 392 5 125 F6125 with relatively low pressure loss. These valves may be
used for isolation (shut-off) service or throttling service
DR

1579 605 6 150 F6150 within a range of 0-60 degrees for two-way valves.
Butterfly valves are controlled with a maintenance-free
3136 1202 8 200 F6200L electronic actuator or manually with an ergonomic handle
PR

or gear operator.

PKR
5340 2047 10 250 F6250L
PR

Product Features
8250 3162 12 300 F6300L The unique disc and seat design ensures positive valve
seating while maintaining low seating torque.
11917 4568 14 350 F6350
(2 Year Warranty)

16388 6282 16 400 F6400 Actuator Specifications


SY Series

21705 8320 18 450 F6450 Control type on/off, floating point,


modulating, 2-10 VDC,
27908 10698 20 500 F6500 multi-function technology
(MFT)
43116 16528 24 600 F6600 Manual override all models
Electrical connection 3 ft. [1 m] cable
terminal block (-T models)
Communication (PR) BACnet MS/TP, NFC,
3-way Suitable Actuators listed by BTL, Modbus

Fail-Safe
Valve Valve Specifications
Type Non Fail-Safe Spring
Nominal Size Electronic Service chilled, hot water,
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

Return 60% glycol


Flow characteristic F6 modified equal percentage
Cv Cv DN F7 modified linear
IN 3-way HDU L HD HD L HD
90° 60° [mm] Sizes 2” to 24”
End fitting for ASME/ANSI Class
AM

115 44 2 50 F750
All prices are in US Dollars (USD)

GM Series

125/150 flanges
AF

196 75 2½ 65 F765 Materials


Body ductile iron ASTM A536
GM

302 116 3 80 F780


PKR Series GK

Body finish polyester powder coat


600 230 4 100 F7100 Disc 304 stainless steel
PR Series

Shaft HD Series: 416 stainless steel


Series
2*GM

1022 392 5 125 F7125 L Series: 420 stainless steel


Seat EPDM
1579 605 6 150 F7150 O-rings EPDM
Bushings HD Series: RPTFE
3136 1202 8 200 F7200L
L Series: bronze, steel, PTFE
PKR

5340 2047 10 250 F7250L


PR

Media (water) temp. range -22°F to +250°F


[-30°C to +120°C]
8250 3162 12 300 F7300L
Body pressure rating 232 psi cold working
11917 4568 14 350 F7350 pressure (CWP)
SY Series

Warranty)
(2 Year

Close-off pressure HDU, LU: 50 psi, 3” to 10”


16388 6282 16 400 F7400 HD: 200 psi, 2” to 6”
21705 8320 18 450 F7450 HD: 150 psi, 14” to 24”
L Series: 200 psi 8” to 12”
Rangeability 10:1
Maximum velocity 12 FPS
Leakage 0%

16-1
Grooved Butterfly Valve Product Range

2-way Suitable Actuators


Valve
Type Non Fail-Safe Fail-Safe
Nominal Size
Cv Cv DN Spring
IN 2-way Electronic
90° 60° [mm] Return
115 36 2 50 F650VIC
Series

AF Series
AM

260 80 2½ 65 F665VIC

PR / PKR Series
GM/GR
Series
440 140 3 80 F680VIC
Mode of Operation

PKR GK
820 250 4 100 F6100VIC Grooved butterfly valves are designed for body pressures

1200 370 5 125 F6125VIC DR Series ranging from full vacuum to 300 psi and for bi-directional,

Series
dead end services to full body pressure. The valve patented
1800 560 6 150 F6150VIC seat design ensures full 360° sealing. The pressure-
enhanced seat compresses to form a larger seating area as
3400 1050 8 200 F6200VIC the pressure increases. Valve construction and performance
SY (2 Year
Warranty)
meet and exceed MSS-SP-67 requirements.
5800 1800 10 250 F6250VIC
Product Features
9000 2790 12 300 F6300VIC The unique single offset disc and seat design ensures
positive valve seating while maintaining low seating torque.

Actuator Specifications
Control type on/off, floating point,
modulating, 2-10 VDC,
3-way Suitable Actuators multi-function technology (MFT)
Manual override all models
Valve Electrical connection 3 ft. [1 m] cable
Type Non Fail-Safe Fail-Safe
Nominal Size terminal block (-T models)
Cv Cv DN Spring Communication (PR) BACnet MS/TP, NFC,
IN 3-way Electronic listed by BTL, Modbus
90° 60° [mm] Return
AM

115 36 2 50 F750VIC
AF

Valve Specifications
PR / PKR Series

260 80 2½ 65 F765VIC Service chilled, hot water,


PKR Series
Series

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


GM

60% glycol
440 140 3 80 F780VIC Flow characteristic F6 modified equal percentage
820 250 4 100 F7100VIC F7 modified linear
Sizes 2” to 12”
1200 370 5 125 F7125VIC End fitting grooved ANSI/AWWA (C606)

All prices are in US Dollars (USD)


1800 560 6 150 F7150VIC Materials*
Body ductile iron ASTM A536,
Warranty)
SY Series

3400 1050 8 200 F7200VIC


(2 Year

grade 65-45-12
5800 1800 10 250 F7250VIC Body finish black alkyd enamel
Disc electrolysis nickel coated
9000 2790 12 300 F7300VIC ductile iron
Shaft 416 stainless steel
Seat EPDM
Bearings fiberglass with TFE lining
Media temp. range -22°F to +250°F
[-30°C to +120°C]
Body pressure rating 300 psi
Close-off pressure 200 psi (for most combinations)
Rangeability 100:1
Maximum velocity 20 FPS
Leakage 0%

*VIC® 300 Masterseal™ is manufactured by


Victaulic Company

16-2
High Performance Butterfly Valve Product Range

2-way Valves Suitable Actuators

Valve Fail-Safe
Nominal Type Non Fail-Safe Spring
Size Electronic
Return
Cv Cv ANSI 150 ANSI 300
Inches 150 300 150 300 150 300
90° 60° 2-way 2-way
102 56 2 F650-150SHP F650-300SHP

GM Series

GM Series

GK Series

GK Series
AF Series

AF Series
146 80 2½ F665-150SHP F665-300SHP

PR Series
Mode of Operation

PR Series
228 125 3 F680-150SHP F680-300SHP High performance butterfly valves are designed for
451 248 4 F6100-150SHP F6100-300SHP modulating and isolation service and feature a machined
seat design and blow out proof solid shaft, providing
714 392 5 F6125-150SHP F6125-300SHP better torque consistency, which offers longer actuator

PKR

PKR
life and reduced risk of leakage. Available for a variety of
1103 607 6 F6150-150SHP F6150-300SHP high temperature and pressure ratings i.e., ASME/ANSI
Class 300 or 150. Valve sizes range from 2 to 24 inches,
2064 1135 8 F6200-150SHP F6200-300SHP
with rangeabilities of 100:1, 0% leakage ratings, and a

SY (2 Year Warranty)
SY Series (2 Year Warranty)
3517 1934 10 F6250-150SHP F6250-300SHP maximum valve velocity of 32 FPS.

4837 2660 12 F6300-150SHP F6300-300SHP Product Features


Unique body seat and double offset disc design ensures
6857 3592 14* F6350-150SHP F6350-300SHP positive valve sealing to help assure leak free performance
in water applications while maintaining low seating torque.
9287 4865 16* F6400-150SHP F6400-300SHP
Actuator Specifications
11400 6270 18* F6450-150SHP
Control type on/off, floating point,
14420 7590 20* F6500-150SHP modulating, 2-10 VDC,
multi-function technology
22050 11550 24* F6600-150SHP (MFT)
Note: Cv values listed for ANSI Class 150 Butterfly Valves. Please consult the technical documentation for ANSI Class 300 Cv values Manual override all models
and configurations. Electrical connection 3 ft. [1 m] cable
*Call Customer Service at 1-800-543-9038 for product availability. Longer lead times may apply. terminal block (-T models)
Communication (PR) BACnet MS/TP, NFC,
listed by BTL, Modbus
3-way Valves Suitable Actuators
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

Valve Specifications
Valve
Electronic Service chilled or hot water,
Nominal Type Non Fail-Safe
Fail-Safe 60% glycol, steam to 50 psi
Size
Flow characteristic F6 modified equal percentage,
Cv Cv ANSI 150 ANSI 300 unidirectional
All prices are in US Dollars (USD)

Inches 150 300 150 300


90° 60° 3-way 3-way F7 modified linear,
unidirectional
102 56 2 F750-150SHP F750-300SHP
GM Series

GK Series

Sizes 2” to 24”
GM Series

PR Series

PR Series

GK Series

146 80 2½ F765-150SHP F765-300SHP End fitting ASME/ANSI Class 150 or 300


Materials
228 125 3 F780-150SHP F780-300SHP Body carbon steel full lug
Disc 316 stainless steel
PKR

451 248 4 F7100-150SHP F7100-300SHP


Shaft 17-4 PH stainless
714 392 5 F7125-150SHP F7125-300SHP Seat RTFE
Gland seal TFE
1103 607 6 F7150-150SHP F7150-300SHP Bearings glass backed PTFE
(2 Year Warranty)

(2 Year Warranty)

2064 1135 8 F7200-150SHP F7200-300SHP Media temp. range -22°F to +400°F


SY Series

SY Series

[-30°C to +204°C]
3517 1934 10 F7250-150SHP F7250-300SHP Body pressure rating 150 SHP: ASME/ANSI Class 150
4837 2660 12 F7300-150SHP F7300-300SHP 300 SHP: ASME/ANSI Class 300
Close-off pressure 150: 285 psi, 300: 600 psi
6857 3592 14* F7350-150SHP Rangeability 100:1
9287 4865 16* F7400-150SHP Maximum velocity 32 FPS
Leakage 0%
Note: Cv values listed for ANSI Class 150 Butterfly Valves. Please consult the technical documentation for ANSI Class 300 Cv
values and configurations. Double Dead End Service: Utilizes larger retainer ring set
*Call Customer Service at 1-800-543-9038 for product availability. Longer lead times may apply. screws to allow the valve to be placed at the end of the
line without a down stream flange in either flow direction
while still holding full pressure.

16-3
Butterfly Valve Selection
HD, L, VIC Series Valves, 3-way Configuration

ON/OFF OR ON/OFF OR ON/OFF OR


MOD@2 VDC MASTER MOD@2 VDC MASTER MOD@2 VDC MASTER
CONFIG MASTER VALVE CONFIG MASTER VALVE CONFIG MASTER VALVE
CODE VALVE IS @ FAIL CODE VALVE IS @ FAIL CODE VALVE IS @ FAIL
X10 OPEN FAIL IN PLACE X20 OPEN FAIL IN PLACE X30 OPEN FAIL IN PLACE
X11 OPEN OPEN X21 OPEN OPEN X31 OPEN OPEN
X12 OPEN CLOSED X22 OPEN CLOSED X32 OPEN CLOSED
X13 CLOSED FAIL IN PLACE X23 CLOSED FAIL IN PLACE X33 CLOSED FAIL IN PLACE
X14 CLOSED OPEN X24 CLOSED OPEN X34 CLOSED OPEN
X15 CLOSED CLOSED X25 CLOSED CLOSED X35 CLOSED CLOSED
X Specifies Bi-Directional Flow Capability

Notes:
1. Slave Valve operates inversely of the Master Valve.
2. The Master Valve is always located on the run.
3. The Slave Valve may also have an actuator if required (Direct Coupled).
4. On/Off actuator normal position is a function of field logic.
5. Modulating actuator normal position (i.e., fully CW or fully CCW) is set by the direction control switch or field programming via NFC app.
6. All 3-way assemblies are designed for 90 degree actuator rotation.
7. Actuators installed default over Master Valve.

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


All prices are in US Dollars (USD)
BUTTERFLY VALVES

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

16-4
Butterfly Valve Selection
150 SHP/300 SHP Series Valves, 3-way Configuration

SHP Series Valves are Flow Direction Specific.


MIXING
DIVERTING

ON/OFF OR ON/OFF OR ON/OFF OR


MOD@2VDC MASTER MOD@2VDC MASTER MOD@2VDC MASTER
CONFIG MASTER VALVE CONFIG MASTER VALVE CONFIG MASTER VALVE
CODE VALVE IS @ FAIL CODE VALVE IS @ FAIL CODE VALVE IS @ FAIL
M(D)10 OPEN FAIL IN PLACE M(D)20 OPEN FAIL IN PLACE M(D)30 OPEN FAIL IN PLACE
M(D)11 OPEN OPEN M(D)21 OPEN OPEN M(D)31 OPEN OPEN
M(D)12 OPEN CLOSED M(D)22 OPEN CLOSED M(D)32 OPEN CLOSED
M(D)13 CLOSED FAIL IN PLACE M(D)23 CLOSED FAIL IN PLACE M(D)33 CLOSED FAIL IN PLACE
M(D)14 CLOSED OPEN M(D)24 CLOSED OPEN M(D)34 CLOSED OPEN
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

M(D)15 CLOSED CLOSED M(D)25 CLOSED CLOSED M(D)35 CLOSED CLOSED


M Specifies MIXING, D Specifies DIVERTING

Notes:
1. Slave Valve operates inversely of the Master Valve.
All prices are in US Dollars (USD)

2. The Master Valve is always located on the run.


3. The Slave Valve may also have an actuator if required (Direct Coupled).
4. On/Off actuator normal position is a function of field logic.
5. Modulating actuator normal position (i.e., fully CW or fully CCW) is set by the direction control switch or field programming via NFC app.
6. All 3-way assemblies are designed for 90 degree actuator rotation.
7. Actuators installed default over Master Valve.

BUTTERFLY VALVES

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

16-5
Butterfly Valve Selection
Velocity Chart

Flow in Schedule 40 Pipe (Fluid Velocity in GPM). Use with HD/L Series Butterfly Valves.
VALVE SIZE 2 FPS 4 FPS 6 FPS 8 FPS 10 FPS 12 FPS
HD 2” 19 39 59 78 98 117
HD 2½” 30 61 92 122 153 184
HD 3” 44 88 132 176 220 264
HD 4” 78 157 235 313 392 470
HD 5” 122 245 367 490 612 734
HD 6” 176 352 529 705 881 1058
L 8” 313 627 940 1253 1567 1880
L 10” 490 979 1469 1958 2448 2738
L 12” 705 1410 2115 2820 3525 4230
HD 14” 959 1919 2879 3838 4798 5758
HD 16” 1253 2507 3760 5013 6267 7520
HD 18” 1586 3173 4759 6345 7931 9518
HD 20” 1958 3917 5875 7834 9792 11750
HD 24” 2820 5640 8460 11280 14100 16921
It is not recommended to exceed 12 feet per second through resilient seat butterfly valves.
Velocities greater than 12 fps may damage the valve liner and disc. Torque may increase, potentially exceeding the actuator’s capacity.

Flow in Schedule 40 Pipe (Fluid Velocity in GPM). Use with Grooved Series Butterfly Valves.
SIZE 1 FPS 3 FPS 5 FPS 8 FPS 10 FPS 12 FPS 15 FPS 16 FPS 20 FPS
2” 10 31 52 84 105 126 157 167 209
2½” 15 45 75 119 149 179 224 239 298
3” 23 69 115 184 230 277 346 369 461
4” 40 119 198 317 397 476 595 635 794
5” 62 187 312 499 624 748 935 998 1247
6” 90 270 450 720 900 1081 1351 1441 1801
8” 156 468 780 1247 1559 1871 2339 2495 3119
10” 246 737 1229 1966 2458 2949 3687 3932 4916
12” 353 1058 1763 2820 3525 4230 5288 5640 7050
It is not recommended to exceed 20 feet per second through grooved butterfly valves. Velocities greater than 20 fps may damage the valve.

SHP Flow in Schedule 40 Pipe (Fluid Velocity in GPM). Use with SHP Series Butterfly Valves.
SIZE 4 FPS 8 FPS 12 FPS 16 FPS 20 FPS 24 FPS 28 FPS 32 FPS
2” 39 78 118 157 196 235 274 313
2½” 61 122 184 245 306 367 428 490

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


3” 88 176 264 353 441 529 617 705
4” 157 313 470 627 783 940 1097 1253
5” 245 490 734 979 1224 1469 1714 1958
6” 352 705 1058 1410 1763 2115 2468 2820
8” 627 1253 1880 2507 3133 3760 4387 5013

All prices are in US Dollars (USD)


10” 979 1958 2738 3917 4896 5875 6854 7834
12” 1410 2820 4230 5640 7050 8460 9870 11280
14” 1919 3838 5758 7677 9596 11515 13435 15354
16” 2507 5013 7520 10027 12534 15040 17547 20054
18” 3173 6345 9518 12690 15863 19036 22208 25381
20” 3917 7834 11750 15667 19584 23501 27418 31334
24” 5640 11280 16921 22561 28201 33841 39481 45121
It is not recommended to exceed 32 feet per second through high performance butterfly valves. Velocities greater than 32 fps may damage the valve.

Max GPM = Maximum US gallons of water (gpm) per minute, at room temperature that will flow through the fully 90° open valve without exceeding design velocity
limits.
BUTTERFLY VALVES

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

16-6
Butterfly Valve Actuators

CONTROL TYPE
Run Time(s) 90°
SERIES MODEL # Power Supply Duty Cycle Modulating 3 Point On/Off Feedback List Price
@60Hz
PRBUP-3-T* 35 seconds (default) 24-240 VAC/ 24-125 VDC, 50/60 Hz 100% • • none $2,503
PRXUP-3-T* 35, 30 - 120 seconds 24-240 VAC/ 24-125 VDC, 50/60 Hz 100% • • none $2,503
PR
PRBUP-MFT-T* 35 seconds (default) 24-240 VAC/ 24-125 VDC, 50/60 Hz 100% • • • 2-10 VDC $4,797
PRXUP-MFT-T* 35, 30 - 120 seconds 24-240 VAC/ 24-125 VDC, 50/60 Hz 100% • • • 2-10 VDC $4,797
PKR PKRXUP-MFT-T* 35, 30 - 120 seconds 24-240 VAC/ 24-125 VDC, 50/60 Hz 100% • • • 2-10 VDC $5,831
SY4-110 19 seconds 120 VAC ±10%, 50/60 Hz 30% • • none, opt 1k Ω $3,306
SY4-24 20 seconds 24 VAC/DC ±10%, 50/60 Hz 30% • • none, opt 1k Ω $3,306
SY4-220 20 seconds 230 VAC ±10%, 50/60 Hz 30% • • none, opt 1k Ω $3,306
SY4
SY4-24MFT 20 seconds 24 VAC/DC ±10%, 50/60 Hz 75% • 2-10 VDC $6,073
SY4-120MFT 24 seconds 120 VAC ±10%, 50/60 Hz 75% • 2-10 VDC $6,073
SY4-230MFT 22 seconds 230 VAC ±10%, 50/60 Hz 75% • 2-10 VDC $6,073
SY5-110 26 seconds 120 VAC ±10%, 50/60 Hz 30% • • none, opt 1k Ω $3,823
SY5-24 26 seconds 24 VAC/DC ±10%, 50/60 Hz 30% • • none, opt 1k Ω $3,823
SY5-220 26 seconds 230 VAC ±10%, 50/60 Hz 30% • • none, opt 1k Ω $3,823
SY5
SY5-24MFT 26 seconds 24 VAC/DC ±10%, 50/60 Hz 75% • 2-10 VDC $6,612
SY5-120MFT 28 seconds 120 VAC ±10%, 50/60 Hz 75% • 2-10 VDC $6,612
SY5-230MFT 28 seconds 230 VAC ±10%, 50/60 Hz 75% • 2-10 VDC $6,612
SY6-110 34 seconds 120 VAC ±10%, 50/60 Hz 30% • • none, opt 1k Ω $4,633
SY6-220 34 seconds 230 VAC ±10%, 50/60 Hz 30% • • none, opt 1k Ω $4,633
SY6
SY6-120MFT 38 seconds 120 VAC ±10%, 50/60 Hz 75% • 2-10 VDC $7,467
SY6-230MFT 35 seconds 230 VAC ±10%, 50/60 Hz 75% • 2-10 VDC $7,467
SY7-110 50 seconds 120 VAC ±10%, 50/60 Hz 30% • • none, opt 1k Ω $5,562
SY7 SY7-120MFT 59 seconds 120 VAC ±10%, 50/60 Hz 75% • 2-10 VDC $8,331
SY7-230MFT 59 seconds 230 VAC ±10%, 50/60 Hz 75% • 2-10 VDC $8,331
SY8-110 51 seconds 120 VAC ±10%, 50/60 Hz 30% • • none, opt 1k Ω $7,698
SY8 SY8-120MFT 79 seconds 120 VAC ±10%, 50/60 Hz 75% • 2-10 VDC $10,528
SY8-230MFT 79 seconds 230 VAC ±10%, 50/60 Hz 75% • 2-10 VDC $10,528
SY9-110 62 seconds 120 VAC ±10%, 50/60 Hz 30% • • none, opt 1k Ω $9,527
SY9 SY9-120MFT 65 seconds 120 VAC ±10%, 50/60 Hz 50% • 2-10 VDC $12,380
SY9-230MFT 72 seconds 230 VAC ±10%, 50/60 Hz 50% • 2-10 VDC $12,380
SY10-110 62 seconds 120 VAC ±10%, 50/60 Hz 30% • • none, opt 1k Ω $9,999
SY10 SY10-120MFT 76 seconds 120 VAC ±10%, 50/60 Hz 50% • 2-10 VDC $12,856
SY10-230MFT 85 seconds 230 VAC ±10%, 50/60 Hz 50% • 2-10 VDC $12,856
SY11-110 62 seconds 120 VAC ±10%, 50/60 Hz 30% • • none, opt 1k Ω $13,308
SY11 SY11-120MFT 71 seconds 120 VAC ±10%, 50/60 Hz 50% • 2-10 VDC $16,180
SY11-230MFT 61 seconds 230 VAC ±10%, 50/60 Hz 50% • 2-10 VDC $16,180
SY12-110 62 seconds 120 VAC ±10%, 50/60 Hz 30% • • none, opt 1k Ω $14,245
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

SY12 SY12-120MFT 76 seconds 120 VAC ±10%, 50/60 Hz 50% • 2-10 VDC $16,931
SY12-230MFT 65 seconds 230 VAC ±10%, 50/60 Hz 50% • 2-10 VDC $16,931
Modulating actuators will accept 0-10 VDC or 2-10 VDC control signals as standard.
All SY actuators are non fail-safe, but can be used with back up systems for fail-safe applications. Fail-safe options available with PKR.
SY products carry a two year warranty when sold as part of an assembly or with a UFLK retrofit kit.
All prices are in US Dollars (USD)

*-200 and -250 versions have the same ratings.

BUTTERFLY VALVES

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

16-7
Butterfly Valve Actuators

Power Supply 24 VAC/VDC Single Phase


Speed Current Draw VA
Model # Torque Override Weight
50 Hz/60 Hz (60 Hz) (60 Hz)
PRBUP-3-T* 1400 in-lbs/ 160 Nm 35 seconds 0.8 A 20 Manual override crank 5.8 kg/12.8 lbs.
PRXUP-3-T* 1400 in-lbs/ 160 Nm 35, 30-120 seconds 0.8 A 20 Manual override crank 5.8 kg/12.8 lbs.
SY4-24 3540 in-lbs/ 400 Nm 16 seconds 9.5 A 228 Hand wheel 22 kg/48.5 lbs.
SY5-24 4430 in-lbs/ 500 Nm 35 seconds 9.4 A 227 Hand wheel 22 kg/48.5 lbs.

Power Supply 120 VAC Single Phase


Current Draw VA
Model # Torque Speed 60 Hz Override Weight
(60 Hz) (60 Hz)
PRBUP-3-T* 1400 in-lbs/ 160 Nm 35 seconds 0.2 A 23 Manual override crank 5.8 kg/12.8 lbs.
PRXUP-3-T* 1400 in-lbs/ 160 Nm 35, 30-120 seconds 0.2 A 23 Manual override crank 5.8 kg/12.8 lbs.
SY4-110 3540 in-lbs/ 400 Nm 18 seconds 1.8 A 216 Hand wheel 22 kg/48.5 lbs.
SY5-110 4430 in-lbs/ 500 Nm 25 seconds 1.8 A 216 Hand wheel 22 kg/48.5 lbs.
SY6-110 5750 in-lbs/ 650 Nm 32 seconds 1.8 A 216 Hand wheel 22 kg/48.5 lbs.
SY7-110 8850 in-lbs/ 1000 Nm 49 seconds 3.5 A 420 Hand wheel 36 kg/79.5 lbs.
SY8-110 13280 in-lbs/ 1500 Nm 50 seconds 4.8 A 576 Hand wheel 36 kg/79.5 lbs.
SY9-110 17700 in-lbs/ 2000 Nm 57 seconds 2.8 A 336 Hand wheel 72 kg/176.4 lbs.
SY10-110 22130 in-lbs/ 2500 Nm 62 seconds 2.9 A 348 Hand wheel 72 kg/176.4 lbs.
SY11-110 26550 in-lbs/ 3000 Nm 69 seconds 3.6 A 432 Hand wheel 72 kg/176.4 lbs.
SY12-110 30980 in-lbs/ 3500 Nm 60 seconds 3.8 A 456 Hand wheel 72 kg/176.4 lbs.

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


Power Supply 230 VAC Single Phase
Current Draw VA
Model # Torque Speed 60 Hz Override Weight
(60 Hz) (60 Hz)
PRBUP-3-T* 1400 in-lbs/ 160 Nm 35 sec. 0.2 A 52 Manual override crank 5.8 kg/12.8 lbs.

All prices are in US Dollars (USD)


PRXUP-3-T* 1400 in-lbs/ 160 Nm 35, 30-120 sec. 0.2 A 52 Manual override crank 5.8 kg/12.8 lbs.
SY4-220 3540 in-lbs/ 400 Nm 18 seconds 0.9 A 207 Hand wheel 22 kg/48.5 lbs.
SY5-220 4430 in-lbs/ 500 Nm 25 seconds 0.9 A 207 Hand wheel 22 kg/48.5 lbs.
SY6-220 5750 in-lbs/ 650 Nm 31 seconds 0.9 A 207 Hand wheel 22 kg/48.5 lbs.

*-200 and -250 versions have the same ratings.


BUTTERFLY VALVES

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

16-8
Butterfly Valve Actuators

Power Supply 24 VAC/VDC Single Phase


Speed Current Draw VA
Model # Torque Override Weight
50 Hz/60 Hz (60 Hz) (60 Hz)
PRBUP-MFT-T* 1400 in-lbs/160 Nm 30-120 sec. 0.9 A 20 Manual override crank 5.8 kg/12.8 lbs.
PRXUP-MFT-T* 1400 in-lbs/160 Nm 30-120 sec. 0.9 A 20 Manual override crank 5.8 kg/12.8 lbs.
PKRXUP-MFT-T* 1400 in-lbs/160 Nm 30-120 sec. 2.2 A 55 Manual override crank 6.4 kg/14.1 lbs.
SY4-24MFT 3540 in-lbs/ 400 Nm 16 seconds 11.0 A 264 Hand wheel 22 kg/48.5 lbs.
SY5-24MFT 4430 in-lbs/ 500 Nm 30 seconds 10.2 A 245 Hand wheel 22 kg/48.5 lbs.

Power Supply 120 VAC Single Phase


Speed Current Draw VA
Model # Torque Override Weight
60 Hz (60 Hz) (60 Hz)
PRBUP-MFT-T* 1400 in-lbs/160 Nm 30-120 sec. 0.2 A 23 Manual override crank 5.8 kg/12.8 lbs.
PRXUP-MFT-T* 1400 in-lbs/160 Nm 30-120 sec. 0.2 A 23 Manual override crank 5.8 kg/12.8 lbs.
PKRXUP-MFT-T* 1400 in-lbs/160 Nm 30-120 sec. 0.3 A 43 Manual override crank 6.4 kg/14.1 lbs.
SY4-120MFT 3540 in-lbs/ 400 Nm 17 seconds 2.4 A 288 Hand wheel 22 kg/48.5 lbs.
SY5-120MFT 4430 in-lbs/ 500 Nm 21 seconds 2.3 A 276 Hand wheel 22 kg/48.5 lbs.
SY6-120MFT 5750 in-lbs/ 650 Nm 29 seconds 2.2 A 264 Hand wheel 22 kg/48.5 lbs.
SY7-120MFT 8850 in-lbs/ 1000 Nm 44 seconds 1.7 A 204 Hand wheel 36 kg/79.5 lbs.
SY8-120MFT 13280 in-lbs/ 1500 Nm 48 seconds 2.6 A 312 Hand wheel 36 kg/79.5 lbs.
SY9-120MFT 17700 in-lbs/ 2000 Nm 47 seconds 3.4 A 408 Hand wheel 72 kg/176.4 lbs.
SY10-120MFT 22130 in-lbs/ 2500 Nm 51 seconds 4.0 A 480 Hand wheel 72 kg/176.4 lbs.
SY11-120MFT 26550 in-lbs/ 3000 Nm 56 seconds 3.0 A 360 Hand wheel 72 kg/176.4 lbs.
SY12-120MFT 30980 in-lbs/ 3500 Nm 62 seconds 3.4 A 408 Hand wheel 72 kg/176.4 lbs.
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

Power Supply 230 VAC Single Phase


Speed Current Draw VA
Model # Torque Override Weight
60 Hz (60 Hz) (60 Hz)
PRBUP-MFT-T* 1400 in-lbs/160 Nm 30-120 sec. 0.1 A 52 Manual override crank 5.8 kg/12.8 lbs.
All prices are in US Dollars (USD)

PRXUP-MFT-T* 1400 in-lbs/160 Nm 30-120 sec. 0.1 A 52 Manual override crank 5.8 kg/12.8 lbs.
PKRXUP-MFT-T* 1400 in-lbs/160 Nm 30-120 sec. 0.2 A 68 Manual override crank 6.4 kg/14.1 lbs.
SY4-230MFT 3540 in-lbs/ 400 Nm 17 seconds 1.1 A 253 Hand wheel 22 kg/48.5 lbs.
SY5-230MFT 4430 in-lbs/ 500 Nm 22 seconds 1.0 A 230 Hand wheel 22 kg/48.5 lbs.
SY6-230MFT 5750 in-lbs/ 650 Nm 32 seconds 1.1 A 253 Hand wheel 22 kg/48.5 lbs.
SY7-230MFT 8850 in-lbs/ 1000 Nm 44 seconds 0.8 A 184 Hand wheel 36 kg/79.5 lbs.
SY8-230MFT 13280 in-lbs/ 1500 Nm 57 seconds 1.4 A 322 Hand wheel 36 kg/79.5 lbs.
SY9-230MFT 17700 in-lbs/ 2000 Nm 61 seconds 1.1 A 253 Hand wheel 72 kg/176.4 lbs.
SY10-230MFT 22130 in-lbs/ 2500 Nm 70 seconds 1.4 A 322 Hand wheel 72 kg/176.4 lbs.
SY11-230MFT 26550 in-lbs/ 3000 Nm 48 seconds 1.9 A 437 Hand wheel 72 kg/176.4 lbs.
SY12-230MFT 30980 in-lbs/ 3500 Nm 51 seconds 2.0 A 460 Hand wheel 72 kg/176.4 lbs.

*-200 and -250 versions have the same ratings.


BUTTERFLY VALVES

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

16-9
Customize Products
Default and MFT Programming Codes

CONTROL
CONFIGURATION
ACTUATOR TYPE CODE CONTROL INPUT FEEDBACK POSITION RUNNING TIME** List Price
DESCRIPTION
-MFT P-10001* A01* 2-10 VDC 2-10 VDC 150 seconds No Charge
Standard Actuator Series: AR, AM, GR,

P-10002 A02 0.5-10 VDC 0-10 VDC 150 seconds No Charge


P-10003 A03 2-10 VDC 0-5.10 VDC 150 seconds No Charge
GM,GKR, AFR, AF, DKR

P-10019 A19 2-10 VDC 2-10 VDC 100 seconds No Charge


P-10028 A28 0.5-10 VDC 0.5-10 VDC 100 seconds No Charge
P-10063 A63 0.5-4.5 VDC 0.5- 4.5 VDC 150 seconds No Charge
P-10064 A64 5.5-10 VDC 5.5-10.0 VDC 150 seconds No Charge
P-20002 W02 0.02 to 5.00 seconds PWM 2-10 VDC 150 seconds No Charge
P-20003 W03 0.10 to 25.50 seconds PWM 2-10 VDC 150 seconds No Charge
P-30001 F01 Floating Point 2-10 VDC 150 seconds No Charge
P-40002 J02 On/Off 2-10 VDC 150 seconds No Charge
-3, -T N/A L01* On/Off N/A 35 seconds No Charge
N/A L02 On/Off N/A 60 seconds No Charge
-MFT NC L05* 2-10 VDC 2-10 VDC 35 seconds No Charge
NC L06 2-10 VDC 2-10 VDC 60 seconds No Charge
NC L09 0.5-10 VDC 0.5-10 VDC 35 seconds No Charge
PR Series

NC L0A 0.5-10 VDC 0.5-10 VDC 60 seconds No Charge


NC L0D 4-20 mA 2-10 VDC 35 seconds No Charge
NC L0E 4-20 mA 2-10 VDC 60 seconds No Charge
NO L0H 2-10 VDC 2-10 VDC 35 seconds No Charge
NO L0J 2-10 VDC 2-10 VDC 60 seconds No Charge
NO L0M 0.5-10 VDC 0.5-10 VDC 35 seconds No Charge
NO L0R 4-20 mA 2-10 VDC 35 seconds No Charge
NC-FC L21 On/Off, Floating Point 2-10 VDC 35 seconds No Charge
NC-FO L25 On/Off, Floating Point 2-10 VDC 35 seconds No Charge
NO-FC L29 On/Off, Floating Point 2-10 VDC 35 seconds No Charge
NO-FO L2D On/Off, Floating Point 2-10 VDC 35 seconds No Charge
NC-FC L31* 2-10 VDC 2-10 VDC 35 seconds No Charge
NC-FO L35 2-10 VDC 2-10 VDC 35 seconds No Charge

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


NO-FC L39 2-10 VDC 2-10 VDC 35 seconds No Charge
NO-FO L3D 2-10 VDC 2-10 VDC 35 seconds No Charge
PKR Series

NC-FC L41 0.5-10 VDC 0.5-10 VDC 35 seconds No Charge


NC-FO L45 0.5-10 VDC 0.5-10 VDC 35 seconds No Charge

All prices are in US Dollars (USD)


NO-FC L49 0.5-10 VDC 0.5-10 VDC 35 seconds No Charge
NO-FO L4D 0.5-10 VDC 0.5-10 VDC 35 seconds No Charge
NC-FC L51 4-20 mA 2-10 VDC 35 seconds No Charge
NC-FO L55 4-20 mA 2-10 VDC 35 seconds No Charge
NO-FC L59 4-20 mA 2-10 VDC 35 seconds No Charge
NO-FO L5D 4-20 mA 2-10 VDC 35 seconds No Charge
NO-FO L5E 4-20 mA 2-10 VDC 60 seconds No Charge
-MFT Loss of Signal Stop ACE* 2-10 VDC 2-10 VDC Varies (15-20 seconds) No Charge
Loss of Signal Stop ACF 0.5-10 VDC 0.5-10 VDC Varies (15-20 seconds) No Charge
Loss of Signal Stop ACG 4-20 mA 4-20 mA Varies (15-20 seconds) No Charge
Loss of Signal Open ACJ 2-10 VDC 2-10 VDC Varies (15-20 seconds) No Charge
SY Series

Loss of Signal Open ACK 0.5-10 VDC 0.5-10 VDC Varies (15-20 seconds) No Charge
Loss of Signal Open ACL 4-20 mA 4-20 mA Varies (15-20 seconds) No Charge
Loss of Signal Close ACN 2-10 VDC 2-10 VDC Varies (15-20 seconds) No Charge
Loss of Signal Close ACP 0.5-10 VDC 0.5-10 VDC Varies (15-20 seconds) No Charge
Loss of Signal Close ACR 4-20 mA 4-20 mA Varies (15-20 seconds) No Charge
*Default configuration
BUTTERFLY VALVES

**Additional running times available upon request

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

16-10
F6/F7 HD and HDU Series Butterfly Valves with Non Fail-Safe Actuators
2-way and 3-way Valves, Undercut and Full Rated Disc

Valve Specifications
chilled or hot water, up to 60%
Service
glycol
F6- modified equal percentage
Flow Characteristic
F7- modified linear
for use with ANSI Class 125/150
End Fitting
flanges
Body ductile iron ASTM A536
Body Finish polyester powder coated
Disc 304 stainless steel
Shaft 416 stainless steel
Seat EPDM
O-ring EPDM
Bushings RPTFE
Media Temperature Range
-22°F to +250°F [-30°C to +120°C]
(Water)
Rangeabilty 10:1
Maximum Velocity 12 FPS
ACTUATOR PART # ARX24-3 ARX24-MFT GRX24-3 GRCX120-3 GRX24-MFT DRCX24-3-T DRCX120-3 DRX24-MFT-T
On/Off, Modulating/ On/Off, On/Off, Modulating/ On/Off, On/Off, Modulating/
Control
Floating Point MFT Floating Point Floating Point MFT Floating Point Floating Point MFT
Manual Override • • • • • • • •
150 seconds 150 seconds 150 seconds
Running Time (Motor) 90 seconds 150 seconds 35 seconds 35 seconds 35 seconds
(variable) (variable) (variable)
3 ft, 18 GA 3 ft, 18 GA 3 ft, 18 GA 3 ft, 18 GA 3 ft, 18 GA 3 ft, 18 GA
appliance rated appliance rated plenum rated appliance rated appliance rated screw terminal appliance rated screw terminal
Electrical Connection cable with cable with cable with cable with cable with (for 22 to 12 cable with (for 22 to 12
½” conduit ½” conduit ½” conduit ½” conduit ½” conduit AWG wire) ½” conduit AWG wire)
connector connector connector connector connector connector
2-Way Undercut Disc
Body Close-Off
Cv Cv Size
Model # Pressure Pressure
90° 60° [mm] Rating [psi]
F680HDU 302 116 3” [80] 50 $784 $949
F6100HDU 600 230 4” [100] 232 psi 50 $1,019 $1,006 $1,117
F6125HDU 1022 392 5” [125] CWP 50 $1,132 $1,130 $1,230
F6150HDU 1579 605 6” [125] 50 $1,666 $1,643 $1,881

2-Way Full Rated Disc


Body Close-Off
Cv Cv Size
Model # Pressure Pressure
90° 60° [mm] Rating [psi]
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

F650HD 115 44 2” [50] 200 $721 $874 $767


F665HD 196 75 2½” [65] 200 $753 $912 $798
232 psi
F680HD 302 116 3” [80] 200 $905 $950 $1,024
CWP
F6100HD 600 230 4” [100] 200 $1,228 $1,232 $1,383
F6125HD 1022 392 5” [125] 200 $1,327 $1,386 $1,480
All prices are in US Dollars (USD)

ACTUATOR PART # AMB24-3-X1 AMX24-MFT-X1 GMB24-3-X1 GMX120-SR-T-X1 GMX24-MFT-X1 2*GMX24-MFT-X1


Control On/Off, Floating Point Modulating/MFT On/Off, Floating Point Modulating Modulating/MFT Modulating/MFT
Manual Override • • • • • •
150 seconds 150 seconds 150 seconds
Running Time (Motor) 90 seconds 150 seconds 90 seconds
(variable) (variable) (variable)
3 ft, 18 GA plenum 3 ft, 18 GA plenum 3 ft, 18 GA plenum screw terminal 3 ft, 18 GA plenum 18 GA applicance
Electrical Connection rated cable with ½” rated cable with ½” rated cable with ½” (for 22 to 12 rated cable with ½” rated cable with ½”
conduit connector conduit connector conduit connector AWG wire) conduit connector conduit connector

3-Way Mixing/Diverting Undercut Disc


Body Close-Off
Cv Cv Size
Model # Pressure Pressure
90° 60° [mm] Rating [psi]
F780HDU 302 116 3” [80] 50 $1,840 $1,954 $2,068
F7100HDU 600 230 4” [100] 232 psi 50 $3,065
F7125HDU 1022 392 5” [125] CWP 50 $3,346
F7150HDU 1579 605 6” [125] 50 $3,443

3-Way Mixing/Diverting Full Rated Disc


Body Close-Off
Cv Cv Size
Model # Pressure Pressure
90° 60° [mm] Rating [psi]
BUTTERFLY VALVES

F750HD 115 44 2” [50] 200 $1,508 $1,712


232 psi
F765HD 196 75 2½” [65] 200 $1,819 $2,039 $2,059
CWP
F780HD 302 116 3” [80] 200 $2,806

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

16-11
F6/F7 HD…Series Butterfly Valves with Fail-Safe Actuators
2-way and 3-way Valves, Standard (Full Rated) Disc

Valve Specifications
chilled or hot water, up to 60%
Service
glycol
F6- modified equal percentage
Flow Characteristic
F7- modified linear
for use with ANSI Class 125/150
End Fitting
flanges
Body ductile iron ASTM A536
Body Finish polyester powder coated
Disc 304 stainless steel
Shaft 416 stainless steel
Seat EPDM
O-ring EPDM
Bushings RPTFE
Media Temperature Range
-22°F to +250°F [-30°C to +120°C]
(Water)
Rangeabilty 10:1
Maximum Velocity 12 FPS

ACTUATOR PART # AFRXUP AFRX24-MFT 2*AFX24-MFT-X1 GKX24-MFT-X1 DKRX24-3-T DKRX24-MFT-T

Control On/Off Modulating/MFT Modulating/MFT Modulating/MFT On/Off, Floating Point Modulating/MFT

Manual Override • • • • • •
Running Time (Motor) <75 seconds 150 seconds (variable) 150 seconds (variable) 150 seconds (variable) 150 seconds (variable) 150 seconds (variable)
Running Time (Fail-Safe) 20 seconds 20 seconds 20 seconds 35 seconds 35 seconds 35 seconds

3 ft, 18 GA appliance 18 GA applicance 18 GA applicance 18 GA applicance


Electrical Connection cables with ½” rated cable with ½” rated cable with ½” rated cable with ½” terminal block terminal block
conduit connector conduit connector conduit connector conduit connector

2-Way
Body Close-Off
Cv Cv Size
Model # Pressure Pressure
90° 60° [mm] Rating [psi]
F650HD 115 44 2” [50] 200 $1,033 $1,123
F665HD 196 75 2½” [65] 200 $1,058 $1,262
232 psi
F680HD 302 116 3” [80] 200 $2,054 $2,140
CWP
F6100HD 600 230 4” [100] 200 $1,614 $2,226
F6125HD 1200 370 5” [125] 200 $2,370 $2,788

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


ACTUATOR PART # AFBUP-X1 AFX24-MFT-X1 GKX24-MFT-X1 2*GKX24-MFT-X1
Control On/Off Modulating/MFT Modulating/MFT Modulating/MFT
Manual Override • • • •
Running Time (Motor) <75 seconds 150 seconds (variable) 150 seconds (variable) 150 seconds (variable)

All prices are in US Dollars (USD)


Running Time (Fail-Safe) 20 seconds <20 seconds 35 seconds 35 seconds

3 ft, 18 GA appliance cable, with 18 GA applicance rated cable with 18 GA plenum rated cable with 18 GA plenum rated cable with
Electrical Connection
½” conduit connector ½” conduit connector ½” conduit connector protected ½” conduit connector

3-Way Mixing/Diverting
Body Close-Off
Cv Cv Size
Model # Pressure Pressure
90° 60° [mm] Rating [psi]
F750HD 115 44 2” [50] 200 $1,768 $2,068
232 psi
F765HD 196 75 2½” [65] 200 $3,014
CWP
F780HD 302 116 3” [80] 200 $3,911
BUTTERFLY VALVES

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

16-12
F6/F7 HD, HDU, and L Series Butterfly Valves
with NEMA 4X Non Fail-Safe Actuators
Valve Specifications 2-way and 3-way Valves, Undercut and Full Rated Disc
chilled or hot water, up to 60%
Service
glycol
Flow Characteristic modified equal percentage
for use with ANSI Class 125/150
End Fitting
flanges
Body ductile iron ASTM A536
Body Finish polyester powder coated
Disc 304 stainless steel
Shaft HD Series 416 stainless steel
L Series 420 stainless steel
Seat EPDM
O-ring EPDM
Bushings HD Series RPTFE
L Series bronze, steel, PTFE
Media Temperature Range
-22°F to +250°F [-30°C to +120°C]
(Water)
Rangeabilty 10:1
Maximum Velocity 12 FPS

GRCX24-3-T GRX24-MFT-T DRCX24-3-T DRX24-MFT-T PRBUP- PRBUP- PRBUP- PRBUP-


ACTUATOR PART #
N4 N4 N4 N4 3-T-200 3-T-250 MFT-T-200 MFT-T-250
On/Off, Floating Modulating/ On/Off, Floating Modulating/ On/Off, Floating On/Off, Floating Modulating/ Modulating/
Control
Point MFT Point MFT Point Point MFT MFT
Manual Override • • • • • • • •
150 seconds 150 seconds 35 seconds 35 seconds 35 seconds 35 seconds
Running Time (Motor) 35 seconds 35 seconds
(variable) (variable) (default) (default) (default) (default)
(2) Temperature Sensor Inputs • •
Default Set Up* 2-10 VDC/NC 2-10 VDC/NC
Electrical Connection terminal block terminal block screw terminal screw terminal terminal block terminal block terminal block terminal block
2-Way Undercut Disc *Field selectable with Belimo Assistant app.
Body Close-Off 
Cv Cv Size Heater option for NEMA 4X products has a list price adder of $500.
Model # Pressure Pressure
90° 60° [mm] Rating [psi]
F680HDU 302 116 3” [80] 50 $1,728 $1,847
F6100HDU 600 230 4” [100] 50 $1,824 $1,943
F6125HDU 1022 392 5” [125] 50 $1,898 $2,016
232 psi
F6150HDU 1579 605 6” [125] CWP 50 $2,783 $3,003
F6200LU 3136 1202 8” [200] 50 $4,066 $5,544
F6250LU 5340 2047 10” [250] 50 $5,182 $7,446

ACTUATOR PART # PRBUP-3-T PRBUP-3-T-200 PRBUP-3-T-250 PRBUP-MFT-T PRBUP-MFT-T-200 PRBUP-MFT-T-250


U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

Control On/Off, Floating Point On/Off, Floating Point On/Off, Floating Point Modulating/MFT Modulating/MFT Modulating/MFT
Manual Override • • • • • •

Running Time (Motor) 35 seconds (default), 35 seconds (default), 35 seconds (default), 35 seconds (default), 35 seconds (default), 35 seconds (default),
30-120 field adjustable 30-120 field adjustable 30-120 field adjustable 30-120 field adjustable 30-120 field adjustable 30-120 field adjustable
(2) Temperature Sensor Inputs • • •
All prices are in US Dollars (USD)

Default Set Up* 2-10 VDC/NC 2-10 VDC/NC 2-10 VDC/NC


Electrical Connection terminal block terminal block terminal block terminal block terminal block terminal block
2-Way Full Rated Disc *Field selectable with Belimo Assistant app.
Body Close-Off
Cv Cv Size
Model # Pressure Pressure
90° 60° [mm] Rating [psi]
F6100HD 600 230 4” [100] 200 $2,690 $4,128
F6125HD 1022 392 5” [125] 200 $3,398 $4,847
F6150HD 1579 605 6” [150] 232 psi 200 $3,534 $4,961
F6200L 3136 1202 8” [200] CWP 200 $5,129 $6,609
F6250L 5340 2047 10” [250] 200 $6,297 $7,714
F6300L 8250 3162 12” [300] 200 $8,098 $9,779
3-Way Mixing/Diverting Full Rated Disc
Body Close-Off
Cv Cv Size
Model # Pressure Pressure
90° 60° [mm] Rating [psi]
F7100HD 600 230 4” [100] 200 $5,536 $6,900
F7125HD 1022 392 5” [125] 200 $5,775 $7,287
F7150HD 1579 605 6” [150] 232 psi 200 $6,598 $7,975
BUTTERFLY VALVES

F7200L 3136 1202 8” [200] CWP 200 $7,776 $9,298


F7250L 5340 2047 10” [250] 200 $10,455 $11,841
F7300L 8250 3162 12” [300] 200 $13,182 $14,601

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

16-13
F6/F7 HD, and L Series Butterfly Valves
with NEMA 4X Electronic Fail-Safe Actuators
2-way and 3-way Valves, Standard (Full Rated) Disc
Valve Specifications
chilled or hot water, up to 60%
Service
glycol
Flow Characteristic modified linear
for use with ANSI Class 125/150
End Fitting
flanges
Body ductile iron ASTM A536
Body Finish polyester powder coated
Disc 304 stainless steel
Shaft HD Series 416 stainless steel
L Series 420 stainless steel
Seat EPDM
O-ring EPDM
Bushings HD Series RPTFE
L Series bronze, steel, PTFE
Media Temperature Range
-22°F to +250°F [-30°C to +120°C]
(Water)
Rangeabilty 10:1
Maximum Velocity 12 FPS

ACTUATOR PART # PKRXUP-MFT-T PKRXUP-MFT-T-200 PKRXUP-MFT-T-250


Control Modulating/MFT Modulating/MFT Modulating/MFT
Manual Override • • •
Running Time (Motor) 35 seconds (default), 30-120 field adjustable 35 seconds (default), 30-120 field adjustable 35 seconds (default), 30-120 field adjustable
Running Time (Fail-Safe) 30 seconds 30 seconds 30 seconds
(2) Temperature Sensor Inputs • • •
BACnet Communication • • •
Electrical Connection terminal block terminal block terminal block
2-Way
Body Close-Off
Cv Cv Size
Model # Pressure Pressure
90° 60° [mm] Rating [psi]
F6100HD 600 230 4” [100] 200 $5,237
F6125HD 1022 392 5” [125] 200 $5,965
F6150HD 1579 605 6” [150] 232 psi 200 $6,081
F6200L 3136 1202 8” [200] CWP 200 $7,764
F6250L 5340 2047 10” [250] 200 $8,886

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


F6300L 8250 3162 12” [300] 200 $10,659

3-Way Mixing/Diverting
Body Close-Off
Cv Cv Size

All prices are in US Dollars (USD)


Model # Pressure Pressure
90° 60° [mm] Rating [psi]
F7100HD 600 230 4” [100] 200 $8,044
F7125HD 1022 392 5” [125] 200 $8,436
F7150HD 1579 605 6” [150] 232 psi 200 $9,132
F7200L 3136 1202 8” [200] CWP 200 $10,494
F7250L 5340 2047 10” [250] 200 $13,075
F7300L 8250 3162 12” [300] 200 $14,898
BUTTERFLY VALVES

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

16-14
F6/F7 HD… Series Butterfly Valves with NEMA 4X Non Fail-Safe Actuators
2-way and 3-way Valves, Standard (Full Rated) Disc

Valve Specifications
chilled or hot water, up to 60%
Service
glycol
F6- modified equal percentage
Flow Characteristic
F7- modified linear
for use with ANSI Class 125/150
End Fitting
flanges
Body ductile iron ASTM A536
Body Finish polyester powder coated
Disc 304 stainless steel
Shaft 416 stainless steel
Seat EPDM
O-ring EPDM
Bushings RPTFE
Media Temperature Range
-22°F to +250°F [-30°C to +120°C]
(Water)
Rangeabilty 10:1
Maximum Velocity 12 FPS

ACTUATOR PART # GRCX24-3-T N4 GRCX120-3 N4 GRCX120-SR-T N4 GRX24-MFT-T N4


Control On/Off, Floating Point On/Off, Floating Point Modulating Modulating/MFT
Manual Override • • • •
150 seconds
Running Time (Motor) 35 seconds 35 seconds 35 seconds
(variable)
3 ft, 18 GA appliance cables with screw terminal
Electrical Connection terminal block terminal block
½” conduit connector (for 22 to 12 AWG wire)

2-Way
Body Close-Off
Cv Cv Size
Model # Pressure Pressure
90° 60° [mm] Rating [psi]
F650HD 115 44 2” [50] 200 $1,557 $1,595 $1,768 $1,940
232 psi
F665HD 196 75 2½” [65] 200 $1,783 $1,819 $1,993 $2,166
CWP
F680HD 302 116 3” [80] 200 $1,812 $1,847 $2,021 $2,194

ACTUATOR PART # DRCX24-3-T N4 DRCX120-3 N4 DRCX24-MFT-T N4 DRX24-MFT-T N4


On/Off, On/Off,
Control Modulating/MFT Modulating/MFT
Floating Point Floating Point
Manual Override • • • •
Running Time (Motor) 35 seconds 35 seconds 35 seconds (variable) 150 seconds (variable)
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

screw terminal (for 22 to 3 ft, 18 GA appliance cables with screw terminal (for 22 to screw terminal (for 22 to
Electrical Connection
12 AWG wire) ½” conduit connector 12 AWG wire) 12 AWG wire)
2-Way
Body Close-Off
Cv Cv Size
Model #
All prices are in US Dollars (USD)

Pressure Pressure
90° 60° [mm] Rating [psi]
4”
F6100HD 600 230 200 $2,715 $2,743 $2,915 $2,915
[100] 232 psi
5” CWP
F6125HD 1200 370 200 $2,842 $5,613 $3,042 $3,042
[125]

ACTUATOR PART # GMCX24-3-T-X1 N4 GMX24-MFT-T-X1 N4 2*GMCX24-3-T-X1 N4 2*GMX24-MFT-T-X1 N4

Control On/Off, Floating Point Modulating/MFT On/Off, Floating Point Modulating/MFT

Manual Override • • • •

Running Time (Motor) 35 seconds 150 seconds (variable) 35 seconds 150 seconds (variable)

Electrical Connection terminal block terminal block terminal block terminal block
3-Way Mixing/Diverting
Body Close-Off
Cv Cv Size
Model # Pressure Pressure
90° 60° [mm] Rating [psi]
F750HD 115 44 2” [50] 200 $2,367 $2,714
232 psi
F765HD 196 75 2½” [65] 200 $2,713 $3,095
CWP
BUTTERFLY VALVES

F780HD 302 116 3” [80] 200 $4,115 $4,881


Heater option for NEMA 4X products has a list price adder of $500.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

16-15
F6 HD…Series Butterfly Valves with NEMA 4X Fail-Safe Actuators
2-way Valves, Standard (Full Rated) Disc

Valve Specifications
chilled or hot water, up to 60%
Service
glycol
Flow Characteristic modified equal percentage
for use with ANSI Class 125/150
End Fitting
flanges
Body ductile iron ASTM A536
Body Finish polyester powder coated
Disc 304 stainless steel
Shaft 416 stainless steel
Seat EPDM
O-ring EPDM
Bushings RPTFE
Media Temperature Range
-22°F to +250°F [-30°C to +120°C]
(Water)
Rangeabilty 10:1
Maximum Velocity 12 FPS

ACTUATOR PART # AFRXUP N4 AFRX24-MFT N4 GKRX24-3 N4


Control On/Off Modulating/MFT On/Off, Floating Point
Manual Override • • •
150 seconds 150 seconds
Running Time (Motor) 75 seconds
(variable) (variable)
Running Time (Fail-Safe) < 20 seconds < 20 seconds 35 seconds
3 ft, 18 GA appliance cables with 18 GA applicance rated cable with 3 ft, 18 GA plenum rated cable with
Electrical Connection
½” conduit connectors ½” conduit connector ½” conduit connector

2-Way
Body Close-Off
Cv Cv Size
Model # Pressure Pressure
90° 60° [mm] Rating [psi]
F650HD 115 44 2” [50] 200 $1,633 $1,861
F665HD 196 75 2½” [65] 232 psi 200 $1,857 $2,132
CWP
F680HD 302 116 3” [80] 200 $3,501

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


ACTUATOR PART # DKRX24-3-T N4 DKRX24-MFT-T N4
Control On/Off, Floating Point Modulating/MFT

All prices are in US Dollars (USD)


Manual Override • •
Running Time (Motor) 150 seconds (variable) 150 seconds (variable)
Running Time (Fail-Safe) 35 seconds 35 seconds
Electrical Connection terminal block terminal block
2-Way
Body Close-Off
Cv Cv Size
Model # Pressure Pressure
90° 60° [mm] Rating [psi]

F6100HD 600 230 4” [100] 200 $2,879 $3,305


232 psi
CWP
F6125HD 1200 370 5” [125] 200 $2,991 $3,417


Heater option for NEMA 4X products has a list price adder of $500.
BUTTERFLY VALVES

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

16-16
F6/F7 HD…Series Butterfly Valves with NEMA 4X Non Fail-Safe Actuators
2-way and 3-way Valves, Standard (Full Rated) Disc

Valve Specifications
chilled or hot water, up to 60%
Service
glycol
F6- modified equal percentage
Flow Characteristic
F7- modified linear
for use with ANSI Class 125/150
End Fitting
flanges
Body ductile iron ASTM A536
Body Finish polyester powder coated
Disc 304 stainless steel
Shaft 416 stainless steel
Seat EPDM
O-ring EPDM
Bushings RPTFE
Media Temperature Range
-22°F to +250°F [-30°C to +120°C]
(Water)
Rangeabilty 10:1
Maximum Velocity 12 FPS

SY5-24, SY5-24MFT,
SY6-110, SY6-120MFT, SY8-120MFT,
ACTUATOR PART # SY5-110, SY5-120MFT, SY8-110
SY6-220 SY6-230MFT SY8-230MFT
SY5-220 SY5-230MFT
Control On/Off, Floating Point Modulating/MFT On/Off, Floating Point Modulating/MFT On/Off, Floating Point Modulating/MFT
Manual Override • • • • • •
Running Time (Motor) 26 seconds 26, 26,28 seconds 34 seconds 38, 35 seconds 51 seconds 79 seconds
Electrical Connection terminal block terminal block terminal block terminal block terminal block terminal block
2-Way
Body Close-Off
Cv Size
Model # Cv 60° Pressure Pressure
90° [mm] Rating [psi]
F6350HD 11917 4568 14” [350] 150 $9,137 $12,413
F6400HD 16388 6282 16” [400] 232 psi 150 $12,524 $13,934
F6450HD 21705 8320 18” [450] CWP 150 $15,399 $17,125
F6500HD 27908 10698 20” [500] 150 $18,603 $20,715
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

SY6-110, SY6-120MFT, SY7-120MFT,


ACTUATOR PART # SY7-110
SY6-220 SY6-230MFT SY7-230MFT

Control On/Off, Floating Point Modulating/MFT On/Off, Floating Point Modulating/MFT


All prices are in US Dollars (USD)

Manual Override • • • •
Running Time (Motor) 34 seconds 38, 35 seconds 50 seconds 59 seconds
Electrical Connection terminal block terminal block terminal block terminal block
3-Way Mixing/Diverting
Body Close-Off
Cv Size
Model # Cv 60° Pressure Pressure
90° [mm] Rating [psi]
14”
F7350HD 11917 4568 150 $22,110 $23,507
[350] 232 psi
16” CWP
F7400HD 16388 6282 150 $24,699 $25,833
[400]
BUTTERFLY VALVES

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

16-17
F6/F7 HD…Series Butterfly Valves with NEMA 4X Non Fail-Safe Actuators
2-way and 3-way Valves, Standard (Full Rated) Disc

Valve Specifications
chilled or hot water, up to 60%
Service
glycol
F6- modified equal percentage
Flow Characteristic
F7- modified linear
for use with ANSI Class 125/150
End Fitting
flanges
Body ductile iron ASTM A536
Body Finish polyester powder coated
Disc 304 stainless steel
Shaft 416 stainless steel
Seat EPDM
O-ring EPDM
Bushings RPTFE
Media Temperature Range
-22°F to +250°F [-30°C to +120°C]
(Water)
Rangeabilty 10:1
Maximum Velocity 12 FPS

SY11-120MFT,
ACTUATOR PART # SY11-110
SY11-230MFT

Control On/Off, Floating Point Modulating/MFT


Manual Override • •
Running Time (Motor) 62 seconds 71, 61 seconds
Electrical Connection terminal block terminal block
2-Way
Body Close-Off
Cv Cv Size
Model # Pressure Pressure
90° 60° [mm] Rating [psi]

24” 232 psi


F6600HD 43116 16528 150 $30,736 $33,508
[600] CWP

SY8-120MFT,
ACTUATOR PART # SY8-110

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


SY8-230MFT

Control On/Off, Floating Point Modulating/MFT


Manual Override • •
Running Time (Motor) 51 seconds 79 seconds
Electrical Connection terminal block terminal block

All prices are in US Dollars (USD)


3-Way Mixing/Diverting
Body Close-Off
Cv Cv Size
Model # Pressure Pressure
90° 60° [mm] Rating [psi]

18” 232 psi


F7450HD 21705 8320 150 $39,416 $43,099
[450] CWP
BUTTERFLY VALVES

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

16-18
F6/F7 Grooved Series Butterfly Valves with Non Fail-Safe Actuators
2-way and 3-way Valves, Grooved End Body

Valve Specifications
chilled or hot water, up to 60%
Service
glycol
F6- modified equal percentage
Flow Characteristic
F7- modified linear
End Fitting grooved ANSI\AWWA (C606)
ductile iron ASTM A536 grade
Body
65-45-12
Body Finish black alkyd enamel
electroless nickel coated ductile
Disc
iron
Shaft 416 stainless steel
Seat EPDM
Media Temperature Range
-22°F to +250°F [-30°C to +120°C]
(Water)
Rangeabilty 100:1
Maximum Velocity 20 FPS

AMX24- GMX120-SR- GMX24- 2*GMX24- DRX24-


ACTUATOR PART # AMB24-3-X1 GMB24-3-X1 DRCX24-3-T
MFT-X1 T-X1 MFT-X1 MFT-X1 MFT-T
On/Off, Floating Modulating/ On/Off, Floating Modulating/ Modulating/ On/Off, Floating Modulating/
Control Modulating
Point MFT Point MFT MFT Point MFT
Manual Override • • • • • • • •
150 seconds 150 seconds 150 seconds
Running Time (Motor) 90 seconds 150 seconds 90 seconds 150 seconds 35 seconds
(variable) (variable) (variable)

3 ft, 18 GA 3 ft, 18 GA 3 ft, 18 GA 3 ft, 18 GA 3 ft, 18 GA


plenum rated plenum rated plenum rated screw terminal plenum rated plenum rated screw terminal screw terminal
Electrical Connection cable with cable with cable with (for 22 to 12 cable with cable with (for 22 to 12 (for 22 to 12
½” conduit ½” conduit ½” conduit AWG wire) ½” conduit ½” conduit AWG wire) AWG wire)
connector connector connector connector connector
2-Way
Body Close-Off
Cv Cv Size
Model # Pressure Pressure
90° 60° [mm] Rating [psi]
F650VIC 115 36 2” [50] 200 $1,663 $1,858
F665VIC 260 80 2½” [65] 200 $2,013 $2,209 $2,185 $2,237 $2,289
F680VIC 440 140 3” [80] 200 $2,288 $2,342 $2,395
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

300
F6100VIC 820 250 4” [100] 200 $3,609 $3,762
F6125VIC 1200 370 5” [125] 200 $3,901 $4,055
F6150VIC 1800 560 6” [150] 200 $4,308 $4,461

3-Way Mixing/Diverting
All prices are in US Dollars (USD)

Body Close-Off
Cv Cv Size
Model # Pressure Pressure
90° 60° [mm] Rating [psi]
F750VIC 115 36 2” [50] 200 $3,991 $4,044 $4,096
F765VIC 260 80 2½” [65] 50 $4,719 $4,771 $4,822
300
F765VIC 260 80 2½” [65] 200 $5,746
F780VIC 440 140 3” [80] 50 $6,074

BUTTERFLY VALVES

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

16-19
F6/F7 Grooved Series Butterfly Valves with Fail-Safe Actuators
2-way and 3-way Valves, Grooved End Body

Valve Specifications
chilled or hot water, up to 60%
Service
glycol
F6- modified equal percentage
Flow Characteristic
F7- modified linear
End Fitting grooved ANSI\AWWA (C606)
ductile iron ASTM A536 grade
Body
65-45-12
Body Finish black alkyd enamel
electroless nickel coated ductile
Disc
iron
Shaft 416 stainless steel
Seat EPDM
Media Temperature Range
-22°F to +250°F [-30°C to +120°C]
(Water)
Rangeabilty 100:1
Maximum Velocity 20 FPS

ACTUATOR PART # AFBUP-X1 AFX24-MFT-X1 2*AFBUP-X1 2*AFX24-MFT-X1 2*GKX24-MFT-X1 PKRXUP-MFT-T


Control On/Off Modulating/MFT On/Off Modulating/MFT Modulating/MFT Modulating/MFT
Manual Override • • • • • •
35 seconds (default),
Running Time (Motor) <75 seconds 150 seconds (variable) 150 seconds 150 seconds (variable) 150 seconds (variable)
30-120 field adjustable
Running Time (Fail-Safe) 20 seconds <20 seconds 20 seconds 20 seconds 35 seconds 30 seconds
3 ft, 18 GA appliance 3 ft, 18 GA appliance 3 ft, 18 GA appliance 3 ft, 18 GA appliance 3 ft, 18 GA appliance
Electrical Connection cable with ½” conduit cable with ½” conduit cable with ½” conduit cable with ½” conduit cable with ½” conduit terminal block
connector connector connector connector connector
2-Way
Body Close-Off
Cv Cv Size
Model # Pressure Pressure
90° 60° [mm] Rating [psi]
F650VIC 115 36 2” [50] 200 $1,891 $2,018
F665VIC 260 80 2½” [65] 50 $2,573 $2,700
F665VIC 260 80 2½” [65] 200 $2,912 $3,166
F680VIC 440 140 3” [80] 300 50 $3,078 $3,332
F6100VIC 820 250 4” [100] 200 $6,075
F6125VIC 1200 370 5” [125] 200 $6,896

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


F6150VIC 1800 560 6” [150] 200 $7,282

3-Way Mixing/Diverting
Body Close-Off
Cv Cv Size
Model # Pressure Pressure
90° 60° [mm] Rating [psi]

All prices are in US Dollars (USD)


F750VIC 115 36 2” [50] 50 $3,997 $4,150
F750VIC 115 36 2” [50] 200 $5,565 $5,865
F765VIC 260 80 2½” [65] 200 $6,506 $9,243
300
F780VIC 440 140 3” [80] 200 $7,020 $9,757
F7100VIC 820 250 4” [100] 200 $10,270
F7125VIC 1200 370 5” [125] 200 $12,324
BUTTERFLY VALVES

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

16-20
F6/F7 Grooved Series Butterfly Valves with
NEMA 4X Non Fail-Safe Actuators
2-way and 3-way Valves, Grooved End Body
Valve Specifications
chilled or hot water, up to 60%
Service
glycol
F6- modified equal percentage
Flow Characteristic
F7- modified linear
End Fitting grooved ANSI\AWWA (C606)
ductile iron ASTM A536 grade
Body
65-45-12
Body Finish black alkyd enamel
electroless nickel coated ductile
Disc
iron
Shaft 416 stainless steel
Seat EPDM
Media Temperature Range
-22°F to +250°F [-30°C to +120°C]
(Water)
Rangeabilty 100:1
Maximum Velocity 20 FPS

SY4-24, SY4-24MFT,
GRCX24-3-T GRCX120-SR-T GRCX24-MFT-
ACTUATOR PART # GRCX120-3 N4 PRBUP-3-T PRBUP-MFT-T SY4-110, SY4-120MFT,
N4 N4 T N4
SY4-220 SY4-230MFT
On/Off, Floating On/Off, Floating Modulating/ On/Off, Floating Modulating/ On/Off, Floating Modulating/
Control Modulating
Point Point MFT Point MFT Point MFT
Manual Override • • • • • • • •
35 seconds 35 seconds
20, 19, 20 20, 24, 22
Running Time (Motor) 35 seconds 35 seconds 35 seconds 35 seconds (default), 30-120 (default), 30-120
seconds seconds
field adjustable field adjustable
(2) Temperature Sensor Outputs •
Default Set Up* 2-10 VDC/NC
3 ft, 18 GA screw terminal
Electrical Connection terminal block appliance rated (for 22 to 12 terminal block terminal block terminal block terminal block terminal block
cable AWG wire)
2-Way *Field selectable with Belimo Assistant app.
Body Close-Off
Cv Cv Size
Model # Pressure Pressure
90° 60° [mm] Rating [psi]
F650VIC 115 36 2” [50] 200 $1,874 $1,977 $2,092 $2,208
F665VIC 260 80 2½” [65] 200 $2,080 $2,182 $2,297 $2,413
F680VIC 440 140 3” [80] 200 $2,213 $2,316 $2,401 $2,490 $3,457 $5,013
F6100VIC 820 250 4” [100] 300 200 $3,772 $5,328
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

F6125VIC 1200 370 5” [125] 200 $4,019 $6,056


F6150VIC 1800 560 6” [150] 200 $4,358 $6,396
F6200VIC 3400 1050 8” [200] 200 $7,328 $8,362
All prices are in US Dollars (USD)

SY4-24, SY4-24MFT,
GMCX24-3-T GMCX120- GMCX120-SR- GMCX24-MFT-
ACTUATOR PART # PRBUP-3-T PRBUP-MFT-T SY4-110, SY4-120MFT,
-X1 N4 3-X1 N4 T-X1 N4 T-X1 N4
SY4-220 SY4-230MFT
On/Off, Floating On/Off, Floating Modulating/ On/Off, Floating Modulating/ On/Off, Floating Modulating/
Control Modulating
Point Point MFT Point MFT Point MFT
Manual Override • • • • • • • •
35 seconds 35 seconds
20, 19, 20 20, 24, 22
Running Time (Motor) 35 seconds 35 seconds 35 seconds 35 seconds (default), 30-120 (default), 30-120
seconds seconds
field adjustable field adjustable
(2) Temperature Sensor Outputs •
Default Set Up* 2-10 VDC/NC
3 ft, 18 GA screw terminal
Electrical Connection terminal block appliance rated (for 22 to 12 terminal block terminal block terminal block terminal block terminal block
cable AWG wire)
3-Way Mixing/Diverting *Field selectable with Belimo Assistant app.
Body Close-Off
Cv Cv Size
Model # Pressure Pressure
90° 60° [mm] Rating [psi]
F750VIC 115 36 2” [50] 200 $3,415 $3,517 $3,620 $3,723
F765VIC 260 80 2½” [65] 50 $4,647 $4,750 $4,802 $4,853
F780VIC 440 140 3” [80] 200 $5,863 $7,459
F7100VIC 820 250 4” [100] 300 200 $6,579 $8,173
F7125VIC 1200 370 5” [125] 200 $10,355 $11,607
BUTTERFLY VALVES

F7150VIC 1800 560 6” [150] 200 $11,628 $13,358


F7200VIC 3400 1050 8” [200] 200 $15,928 $17,916

Heater option for NEMA 4X products has a list price adder of $500.
800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

16-21
F6/F7 Grooved Series Butterfly Valves with NEMA 4X Non Fail-Safe Actuators
2-way and 3-way Valves, Grooved End Body

Valve Specifications
chilled or hot water, up to 60%
Service
glycol
F6- modified equal percentage
Flow Characteristic
F7- modified linear
End Fitting grooved ANSI\AWWA (C606)
ductile iron ASTM A536 grade
Body
65-45-12
Body Finish black alkyd enamel
electroless nickel coated ductile
Disc
iron
Shaft 416 stainless steel
Seat EPDM
Media Temperature Range
-22°F to +250°F [-30°C to +120°C]
(Water)
Rangeabilty 100:1
Maximum Velocity 20 FPS

SY5-24, SY5-110, SY5-24MFT, SY5-120MFT, SY6-110, SY6-120MFT,


ACTUATOR PART #
SY5-220 SY5-230MFT SY6-220 SY6-230MFT

Control On/Off, Floating Point Modulating/MFT On/Off, Floating Point Modulating/MFT


Manual Override • • • •
Running Time (Motor) 26 seconds 26, 26, 28 seconds 34 seconds 38, 35 seconds
Electrical Connection terminal block terminal block terminal block terminal block
2-Way
Body Close-Off
Cv Cv Size
Model # Pressure Pressure
90° 60° [mm] Rating [psi]
F6250VIC 5800 1800 10” [250] 200 $9,354 $10,476
300
F6300VIC 9000 2790 12” [300] 200 $10,377 $11,507

SY6-110, SY6-120MFT, SY7-120MFT,


ACTUATOR PART # SY7-110
SY6-220 SY6-230MFT SY7-230MFT

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


Control On/Off, Floating Point Modulating/MFT On/Off, Floating Point Modulating/MFT
Manual Override • • • •
Running Time (Motor) 34 seconds 38, 35 seconds 50 seconds 59 seconds
Electrical Connection terminal block terminal block terminal block terminal block
3-Way Mixing/Diverting

All prices are in US Dollars (USD)


Body Close-Off
Cv Cv Size
Model # Pressure Pressure
90° 60° [mm] Rating [psi]
F7250VIC 5800 1800 10” [250] 50 $23,372 $25,476 $23,642 $25,833
300
F7300VIC 9000 2790 12” [300] 200 $27,879 $29,812
BUTTERFLY VALVES

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

16-22
F6/F7 ANSI Class 150 Butterfly Valves with Non Fail-Safe Actuators
2-way and 3-way Valves, Reinforced Teflon Seat, 316 Stainless Steel Disc

Valve Specifications
chilled or hot water, up to 60%
Service
glycol, steam
F6- modified equal percentage
Flow Characteristic
F7- modified linear
for use with ASME/ANSI Class
End Fitting
150 flanges
Body carbon steel full lug
Disc 316 stainless steel
Shaft 17-4 PH stainless steel
Seat RPTFE
Gland Seal TFE
Bushings glass backed PTFE
Media Temperature Range
-22°F to +400°F [-30°C to +204°C]
(Water)
Rangeabilty 100:1
Maximum Velocity 32 FPS

ACTUATOR PART # GMB24-3-X1 GMX24-MFT-X1 2*GMX24-MFT-X1


Control On/Off, Floating Point Modulating/MFT Modulating/MFT
Manual Override • • •
Running Time (Motor) 150 seconds 150 seconds (variable) 150 seconds
Noise Level (Motor) <45 dB (A) <45 dB (A) <45 dB (A)
3 ft, 18 GA plenum rated cable with 3 ft, 18 GA plenum rated cable with 3 ft, 18 GA plenum rated cable with
Electrical Connection
½” conduit connector ½” conduit connector ½” conduit connector
2-Way
Body Close-Off
Cv Cv Size
Model # Pressure Pressure
90° 60° [mm] Rating [psi]
F650-150SHP 102 56 2” [50] 285 $2,879 $2,991
F665-150SHP 146 80 2½” [65] ASME/ 285 $2,896 $3,007
F680-150SHP 228 125 3” [80] ANSI Class 285 $2,912 $3,027
F6100-150SHP 451 248 4” [100] 150 150 $3,523 $3,635
F6100-150SHP 451 248 4” [100] 285 $4,074

3-Way Mixing/Diverting
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

Body Close-Off
Cv Cv Size
Model # Pressure Pressure
90° 60° [mm] Rating [psi]
F750-150SHP 102 56 2” [50] 150 $5,820 $5,927
F750-150SHP 102 56 2” [50] 285 $6,355
F765-150SHP 146 80 2½” [65] ASME/ 150 $5,971 $6,075
All prices are in US Dollars (USD)

ANSI Class
F765-150SHP 146 80 2½” [65] 150 285 $6,507
F780-150SHP 228 125 3” [80] 150 $5,979 $6,086
F780-150SHP 228 125 3” [80] 285 $6,544

BUTTERFLY VALVES

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

16-23
F6/F7 ANSI Class 150 Butterfly Valves with Fail-Safe Actuators
2-way and 3-way Valves, Reinforced Teflon® Seat, 316 Stainless Disc

Valve Specifications
chilled or hot water, up to 60%
Service
glycol, steam
F6- modified equal percentage
Flow Characteristic
F7- modified linear
for use with ASME/ANSI Class
End Fitting
150 flanges
Body carbon steel full lug
Disc 316 stainless steel
Shaft 17-4 PH stainless steel
Seat RPTFE
Gland Seal TFE
Bushings glass backed PTFE
Media Temperature Range
-22°F to +400°F [-30°C to +204°C]
(Water)
Rangeabilty 100:1
Maximum Velocity 32 FPS

ACTUATOR PART # 2*AFBUP-X1 2*AFX24-MFT-X1 GKX24-MFT-X1 2*GKX24-MFT-X1 PKRXUP-MFT-T


Control On/Off Modulating/MFT Modulating/MFT Modulating/MFT Modulating/MFT
Manual Override • • • • •

Running Time (Motor) <75 seconds 150 seconds (variable) 150 seconds (variable) 150 seconds (variable) 35 seconds (default),
30-120 field adjustable
Running Time (Fail-Safe) 20 seconds 20 seconds 35 seconds 35 seconds 30 seconds
(2) Temperature Sensor Outputs •
BACnet Communication •
NEMA Rating 2 2 2 2 4X
18 GA applicance rated 18 GA plenum rated 18 GA plenum rated
3 ft, 18 GA appliance cable
Electrical Connection cable with ½” conduit cable with ½” conduit cable with ½” conduit terminal block
with ½” conduit connector
connector connector connector
2-Way
Body Close-Off
Cv Cv Size
Model # Pressure Pressure
90° 60° [mm] Rating [psi]
F650-150SHP 102 56 2” [50] 150 $3,146 $3,346 $3,831
F650-150SHP 102 56 2” [50] 285 $7,168
F665-150SHP 146 80 2½” [65] 150 $3,165 $3,365 $3,849

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


F665-150SHP 146 80 2½” [65] 285 $7,189
F680-150SHP 228 125 3” [80] ASME/ 150 $3,182 $3,382 $3,867
ANSI
F680-150SHP 228 125 3” [80] Class 150 285 $7,487
F6100-150SHP 451 248 4” [100] 150 $3,790 $3,990 $4,474
F6100-150SHP 451 248 4” [100] 285 $5,658 $7,780

All prices are in US Dollars (USD)


F6125-150SHP 714 392 5” [125] 285 $9,031
F6150-150SHP 1103 607 6” [150] 285 $11,092

ACTUATOR PART # GKX24-MFT-X1 2*GKX24-MFT-X1 PKRXUP-MFT-T


Control Modulating/MFT Modulating/MFT Modulating/MFT
Manual Override • • •

Running Time (Motor) 150 seconds (variable) 150 seconds (variable) 35 seconds (default),
30-120 field adjustable
Running Time (Fail-Safe) 35 seconds 35 seconds 30 seconds
(2) Temperature Sensor Outputs •
BACnet Communication •
NEMA Rating 2 2 4X
18 GA plenum rated cable with 18 GA plenum rated cable with
Electrical Connection terminal block
½” conduit connector ½” conduit connector
3-Way Mixing/Diverting
Body Close-Off
Cv Cv Size
Model # Pressure Pressure
90° 60° [mm] Rating [psi]
F750-150SHP 102 56 2” [50] 150 $6,718
F750-150SHP 102 56 2” [50] 285 $7,939 $11,264
F765-150SHP 146 80 2½” [65] ASME/ 150 $6,868
F765-150SHP 146 80 2½” [65] ANSI 285 $8,090 $11,451
BUTTERFLY VALVES

F780-150SHP 228 125 3” [80] Class 150 150 $6,877


F780-150SHP 228 125 3” [80] 285 $8,128 $11,605
F7100-150SHP 451 248 4” [100] 285 $13,677

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

16-24
F6/F7 ANSI Class 150 Butterfly Valves with NEMA 4X Non Fail-Safe Actuators
2-way and 3-way Valves, Reinforced Teflon Seat, 316 Stainless Steel Disc

Valve Specifications
chilled or hot water, up to 60%
Service
glycol, steam
F6- modified equal percentage
Flow Characteristic
F7- modified linear
for use with ASME/ANSI Class
End Fitting
150 flanges
Body carbon steel full lug
Disc 316 stainless steel
Shaft 17-4 PH stainless steel
Seat RPTFE
Gland Seal TFE
Bushings glass backed PTFE
Media Temperature Range
-22°F to +400°F [-30°C to +204°C]
(Water)
Rangeabilty 100:1
Maximum Velocity 32 FPS

SY4-24, SY4-24MFT,
ACTUATOR PART # PRBUP-3-T PRBUP-MFT-T SY4-110, SY4-120MFT,
SY4-220 SY4-230MFT
Control On/Off, Floating Point Modulating/MFT On/Off, Floating Point Modulating/MFT
Manual Override • • • •
35 seconds (default), 35 seconds (default),
Running Time (Motor) 51 seconds 79 seconds
30-120 field adjustable 30-120 field adjustable
(2) Temperature Sensor Outputs •
Default Set Up* 2-10 VDC/NC
Electrical Connection terminal block terminal block terminal block terminal block
2-Way
Body Close-Off
Cv Cv Size
Model # Pressure Pressure
90° 60° [mm] Rating [psi]
F650-150SHP 102 56 2” [50] 285 $4,498 $6,188
F665-150SHP 146 80 2½” [65] 285 $4,517 $6,203
F680-150SHP 228 125 3” [80] 285 $4,535 $6,226
F6100-150SHP 451 248 4” [100] ASME/ 285 $5,336 $6,821
ANSI
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

F6125-150SHP 714 392 5” [125] 285 $6,397 $8,085


Class
F6150-150SHP 1103 607 6” [150] 150 285 $6,431 $8,123
F6200-150SHP 2064 1135 8” [200] 285 $8,369 $10,352
F6250-150SHP 3517 1934 10” [250] 285 $11,335 $13,317
F6300-150SHP 4837 2660 12” [300] 150 $13,855 $15,839
All prices are in US Dollars (USD)

3-Way Mixing/Diverting
Body Close-Off
Cv Cv Size
Model # Pressure Pressure
90° 60° [mm] Rating [psi]
F750-150SHP 102 56 2” [50] 285 $7,413 $9,101
F765-150SHP 146 80 2½” [65] 285 $7,564 $9,252
F780-150SHP 228 125 3” [80] ASME/ 285 $7,575 $9,259
F7100-150SHP 451 248 4” [100] ANSI 285 $9,366 $11,051
F7125-150SHP 714 392 5” [125] Class 285 $11,992 $13,686
F7150-150SHP 1103 607 6” [150] 150 285 $11,999 $13,696
F7200-150SHP 2064 1135 8” [200] 285 $15,672 $17,655
F7250-150SHP 3517 1934 10” [250] 150 $22,704 $24,687

*Field selectable with Belimo Assistant app.


BUTTERFLY VALVES

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

16-25
F6/F7 ANSI Class 150 Butterfly Valves with NEMA 4X Non Fail-Safe Actuators
2-way and 3-way Valves, Reinforced Teflon Seat, 316 Stainless Disc

Valve Specifications
chilled or hot water, up to 60%
Service
glycol, steam
F6- modified equal percentage
Flow Characteristic
F7- modified linear
for use with ASME/ANSI Class
End Fitting
150 flanges
Body carbon steel full lug
Disc 316 stainless steel
Shaft 17-4 PH stainless steel
Seat RPTFE
Gland Seal TFE
Bushings glass backed PTFE
Media Temperature Range
-22°F to +400°F [-30°C to +204°C]
(Water)
Rangeabilty 100:1
Maximum Velocity 32 FPS

SY5-24, SY5-24MFT,
SY7-120MFT, SY8-120MFT, SY10-110, SY10-120MFT,
ACTUATOR PART # SY5-110, SY5-120MFT, SY7-110 SY8-110
SY7-230MFT SY8-230MFT SY10-220 SY10-230MFT
SY5-220 SY5-230MFT
On/Off, Modulating/ On/Off, Modulating/ On/Off, Modulating/ On/Off, Modulating/
Control
Floating Point MFT Floating Point MFT Floating Point MFT Floating Point MFT
Manual Override • • • • • • • •
26, 26, 28
Running Time (Motor) 26 seconds 50 seconds 59 seconds 51 seconds 79 seconds 62 seconds 76, 85 seconds
seconds
Electrical Connection terminal block terminal block terminal block terminal block terminal block terminal block terminal block terminal block
2-Way
Body Close-Off
Cv Cv Size
Model # Pressure Pressure
90° 60° [mm] Rating [psi]
F6300-150SHP 4837 2660 12” [300] 285 $14,193 $16,168
F6350-150SHP 6857 3592 14” [350] 150 $17,657 $19,647
F6350-150SHP 6857 3592 14” [350] ASME/ 285 $18,810 $20,739
ANSI
F6400-150SHP* 9287 4865 16” [400] 150 $26,073 $28,004
Class
F6450-150SHP* 11400 6270 18” [450] 150 285 $31,535 $33,473
F6500-150SHP* 14420 7590 20” [500] 150 $38,501 $40,434

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


F6600-150SHP* 22050 11550 24” [600] 150 $53,158 $55,092

3-Way Mixing/Diverting
Body Close-Off
Cv Cv Size

All prices are in US Dollars (USD)


Model # Pressure Pressure
90° 60° [mm] Rating [psi]
F7250-150SHP 3517 1934 10” [250] ASME/ 285 $23,045 $25,035
F7300-150SHP 4837 2660 12” [300] ANSI 285 $30,502 $32,435
F7350-150SHP* 6857 3592 14” [350] Class 285 $40,671 $42,604
F7400-150SHP* 9287 4865 16” [400] 150 150 $59,288 $61,288

*Call Customer Service at 1-800-543-9038 for product availability. Longer lead times may apply.
BUTTERFLY VALVES

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

16-26
F6 ANSI 300 Class Butterfly Valves with Non Fail-Safe Actuators
2-way and 3-way Valves, Reinforced Teflon Seat, 316 Stainless Disc

Valve Specifications
chilled or hot water, up to 60%
Service
glycol, steam
F6- modified equal percentage
Flow Characteristic
F7- modified linear
for use with ASME/ANSI Class
End Fitting
300 flanges
Body carbon steel full lug
Disc 316 stainless steel
Shaft 17-4 PH stainless steel
Seat RPTFE
Gland Seal TFE
Bushings glass backed PTFE
Media Temperature Range
-22°F to +400°F [-30°C to +204°C]
(Water)
Rangeabilty 100:1
Maximum Velocity 32 FPS

ACTUATOR PART # GMB24-3-X1 GMX24-MFT-X1


Control On/Off, Floating Point Modulating/MFT
Manual Override • •
Running Time (Motor) 150 seconds 150 seconds (variable)
Electrical Connection 3 ft, 18 GA plenum rated cable with ½” conduit connector 3 ft, 18 GA plenum rated cable with ½” conduit connector
2-Way
Body Close-Off
Cv Cv Size
Model # Pressure Pressure
90° 60° [mm] Rating [psi]
F650-300SHP 102 56 2” [50] 285 $3,213 $3,324
F665-300SHP 146 80 2½” [65] ASME/ 285 $3,230 $3,341
ANSI
F680-300SHP 228 125 3” [80] Class 300 285 $3,278 $3,389
F6100-300SHP 451 248 4” [100] 150 $3,767 $3,878

ACTUATOR PART # 2*GMX24-MFT-X1


Control Modulating/MFT
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

Manual Override •
Running Time (Motor) 150 seconds
Electrical Connection 18 GA applicance rated cable with ½” conduit connector
3-Way Mixing/Diverting
Body Close-Off
All prices are in US Dollars (USD)

Cv Cv Size
Model # Pressure Pressure
90° 60° [mm] Rating [psi]
F750-300SHP 102 56 2” [50] 285 $7,585
F765-300SHP 146 80 2½” [65] ASME/ 285 $8,773
ANSI
F780-300SHP 228 125 3” [80] Class 300 285 $8,960
F7100-300SHP 451 248 4” [100] 150 $11,053

BUTTERFLY VALVES

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

16-27
F6/F7 ANSI 300 Class Butterfly Valves with Electronic Fail-Safe Actuators
2-way and 3-way Valves, Reinforced Teflon Seat, 316 Stainless Disc

Valve Specifications
chilled or hot water, up to 60%
Service
glycol, steam
F6- modified equal percentage
Flow Characteristic
F7- modified linear
for use with ASME/ANSI Class
End Fitting
300 flanges
Body carbon steel full lug
Disc 316 stainless steel
Shaft 17-4 PH stainless steel
Seat RPTFE
Gland Seal TFE
Bushings glass backed PTFE
Media Temperature Range
-22°F to +400°F [-30°C to +204°C]
(Water)
Rangeabilty 100:1
Maximum Velocity 32 FPS

ACTUATOR PART # GKX24-MFT-X1 2*GKX24-MFT-X1 PKRXUP-MFT-T


Control Modulating/MFT Modulating/MFT Modulating/MFT
Manual Override • • •
Running Time (Motor) 150 seconds (variable) 150 seconds (variable) 30 seconds (default), 30-120 field adjustable
Running Time (Fail-Safe) 35 seconds 35 seconds 30 seconds
(2) Temperature Sensor Outputs •
BACnet Communication •
NEMA Rating 2 2 4
18 GA plenum rated cable with 18 GA plenum rated cable with
Electrical Connection terminal block
½” conduit connector ½” conduit connector
2-Way
Body Close-Off
Cv Cv Size
Model # Pressure Pressure
90° 60° [mm] Rating [psi]
F650-300SHP 102 56 2” [50] 285 $4,133
F650-300SHP 102 56 2” [50] 400 $5,362 $7,488
F665-300SHP 146 80 2½” [65] 285 $4,153
F665-300SHP 146 80 2½” [65] 400 $5,383 $7,607

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


F680-300SHP 228 125 3” [80] ASME/ANSI 285 $4,172
F680-300SHP 228 125 3” [80] Class 300 400 $5,396 $7,703
F6100-300SHP 451 248 4” [100] 150 $4,689
F6100-300SHP 451 248 4” [100] 285 $5,924 $8,025
F6125-300SHP 714 392 5” [125] 285 $9,911

All prices are in US Dollars (USD)


F6150-300SHP 1103 607 6” [150] 285 $10,065

ACTUATOR PART # 2*GKX24-MFT-X1 PKRXUP-MFT-T


Control Modulating/MFT Modulating/MFT
Manual Override • •
Running Time (Motor) 150 seconds (variable) 30 seconds (default), 30-120 field adjustable
Running Time (Fail-Safe) 35 seconds 30 seconds
(2) Temperature Sensor Outputs •
BACnet Communication •
NEMA Rating 2 4
Electrical Connection 18 GA plenum rated cable with ½” conduit connector terminal block
3-Way Mixing/Diverting
Body Close-Off
Cv Cv Size
Model # Pressure Pressure
90° 60° [mm] Rating [psi]
F750-300SHP 102 56 2” [50] 285 $9,173 $12,170
F765-300SHP 146 80 2½” [65] ASME/ANSI 285 $10,359 $13,481
F780-300SHP 228 125 3” [80] Class 300 285 $10,547 $15,523
F7100-300SHP 451 248 4” [100] 285 $12,639 $16,189
BUTTERFLY VALVES

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

16-28
F6/F7 ANSI 300 Class Butterfly Valves with NEMA 4X Non Fail-Safe Actuators
2-way and 3-way Valves, Reinforced Teflon Seat, 316 Stainless Disc

Valve Specifications
chilled or hot water, up to 60%
Service
glycol, steam
F6- modified equal percentage
Flow Characteristic
F7- modified linear
for use with ASME/ANSI Class
End Fitting
300 flanges
Body carbon steel full lug
Disc 316 stainless steel
Shaft 17-4 PH stainless steel
Seat RPTFE
Gland Seal TFE
Bushings glass backed PTFE
Media Temperature Range
-22°F to +400°F [-30°C to +204°C]
(Water)
Rangeabilty 100:1
Maximum Velocity 32 FPS

SY4-24, SY4-24MFT,
ACTUATOR PART # PRBUP-3-T PRBUP-MFT-T SY4-110, SY4-120MFT,
SY4-220 SY4-230MFT
Control On/Off, Floating Point Modulating/MFT On/Off, Floating Point Modulating/MFT
Manual Override • • • •
35 seconds (default), 35 seconds (default),
Running Time (Motor) 30-120 field adjustable 30-120 field adjustable 20, 19, 20 seconds 20, 24, 22 seconds

(2) Temperature Sensor Outputs •


Default Set Up* 2-10 VDC/NC
Electrical Connection terminal block terminal block terminal block terminal block
2-Way
Body Close-Off
Cv Cv Size
Model # Pressure Pressure
90° 60° [mm] Rating [psi]
F650-300SHP 102 56 2” [50] 600 $4,788 $6,461
F665-300SHP 146 80 2½” [65] 600 $4,805 $6,477
F680-300SHP 228 125 3” [80] 600 $4,823 $6,495
F6100-300SHP 451 248 4” [100] ASME/ 600 $5,328 $6,998
ANSI
F6125-300SHP 714 392 5” [125] 400 $7,055 $8,743
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

Class
F6150-300SHP 1103 607 6” [150] 300 285 $7,239 $8,887
F6200-300SHP 2064 1135 8” [200] 600 $9,913 $11,932
F6250-300SHP 3517 1934 10” [250] 285 $14,387 $16,377
F6300-300SHP 4837 2660 12” [300] 150 $18,583 $20,402
All prices are in US Dollars (USD)

3-Way Mixing/Diverting
Body Close-Off
Cv Cv Size
Model # Pressure Pressure
90° 60° [mm] Rating [psi]
F750-300SHP 102 56 2” [50] 600 $9,460 $11,143
F765-300SHP 146 80 2½” [65] 600 $10,771 $12,454
F780-300SHP 228 125 3” [80] ASME/ 600 $12,814 $14,496
F7100-300SHP 451 248 4” [100] ANSI 400 $13,480 $15,162
F7125-300SHP 714 392 5” [125] Class 600 $18,487 $20,423
F7150-300SHP 1103 607 6” [150] 300 600 $21,588 $23,580
F7200-300SHP 2064 1135 8” [200] 400 $26,065 $28,058
F7250-300SHP 3517 1934 10” [250] 150 $37,721 $39,713

*Field selectable with Belimo Assistant app.


BUTTERFLY VALVES

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

16-29
F6/F7 ANSI 300 Class Butterfly Valves with NEMA 4X Non Fail-Safe Actuators
2-way and 3-way Valves, Reinforced Teflon Seat, 316 Stainless Disc

Valve Specifications
chilled or hot water, up to 60%
Service
glycol, steam
F6- modified equal percentage
Flow Characteristic
F7- modified linear
for use with ASME/ANSI Class
End Fitting
300 flanges
Body carbon steel full lug
Disc 316 stainless steel
Shaft 17-4 PH stainless steel
Seat RPTFE
Gland Seal TFE
Bushings glass backed PTFE
Media Temperature Range
-22°F to +400°F [-30°C to +204°C]
(Water)
Rangeabilty 100:1
Maximum Velocity 32 FPS
SY5-24, SY5-24MFT,
SY7-120MFT, SY8-120MFT,
ACTUATOR PART # SY5-110, SY5-120MFT, SY7-110 SY8-110
SY7-230MFT SY8-230MFT
SY5-220 SY5-230MFT
Control On/Off, Floating Point Modulating/MFT On/Off, Floating Point Modulating/MFT On/Off, Floating Point Modulating/MFT
Manual Override • • • • • •
Running Time (Motor) 26 seconds 26, 26, 28 seconds 50 seconds 59 seconds 51 seconds 79 seconds
Electrical Connection terminal block terminal block terminal block terminal block terminal block terminal block
2-Way
Body Close-Off
Cv Cv Size
Model # Pressure Pressure
90° 60° [mm] Rating [psi]
F6250-300SHP 3517 1934 10” [250] 400 $14,725 $16,716
F6250-300SHP 3517 1934 10” [250] 600 $15,873 $17,817
F6300-300SHP 4837 2660 12” [300] 285 $18,752 $20,745
F6300-300SHP 4837 2660 12” [300] ASME/ 600 $19,903 $21,841
ANSI
F6350-300SHP* 6857 3592 14” [350] 150 $30,388 $32,382
Class
F6350-300SHP* 6857 3592 14” [350] 300 400 $31,542 $32,382
F6350-300SHP* 6857 3592 14” [350] 600 $32,838 $34,779
F6400-300SHP* 9287 4865 16” [400] 150 $32,662 $34,546
F6400-300SHP* 9287 4865 16” [400] 285 $33,924 $35,810

3-Way Mixing/Diverting

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


Body Close-Off
Cv Cv Size
Model # Pressure Pressure
90° 60° [mm] Rating [psi]
F7200-300SHP 2064 1135 8” [200] ASME/ 600 $26,408 $28,399
F7250-300SHP 3517 1934 10” [250] ANSI 600 $39,215 $41,155
F7300-300SHP* 4837 2660 12” [300] Class 400 $51,822 $53,764

All prices are in US Dollars (USD)


F7300-300SHP* 4837 2660 12” [300] 300 600 $53,112 $55,062

*Call Customer Service at 1-800-543-9038 for product availability. Longer lead times may apply.
BUTTERFLY VALVES

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

16-30
Manual Handles and Gear Operators
For HD or L Series Butterfly Valves

VALVE
MANUAL HANDLES HD L LIST PRICE
F650HD+HND01
• $249
2” HD series valve with manual handle ductile iron, 200 psi close-off, Cv 115
F665HD+HND01
• $265
2½” HD series valve with manual handle ductile iron, 200 psi close-off, Cv 196
F680HD+HND01
• $292
3” HD series valve with manual handle ductile iron, 200 psi close-off, Cv 302
F6100HD+HND02
• $385
4” HD series valve with manual handle ductile iron, 200 psi close-off, Cv 600
F6125HD+HND02
• $557
5” HD series valve with manual handle ductile iron, 200 psi close-off, Cv 1022
F6150HD+HND02
• $649
6” HD series valve with manual handle ductile iron, 200 psi close-off, Cv 1579
GEAR OPERATORS
F650HD+GW01
• $397
2” HD series valve with manual gear operator ductile iron, 200 psi close-off, Cv 115
F665HD+GW01
• $523
2½” HD series valve with manual gear operator ductile iron, 200 psi close-off, Cv 196
F680HD+GW01
• $572
3” HD series valve with manual gear operator ductile iron, 200 psi close-off, Cv 302
F6100HD+GW02
• $661
4” HD series valve with manual gear operator ductile iron, 200 psi close-off, Cv 600
F6125HD+GW02
• $784
5” HD series valve with manual gear operator ductile iron, 200 psi close-off, Cv 1022
F6150HD+GW02
• $842
6” HD series valve with manual gear operator ductile iron, 200 psi close-off, Cv 1579
F6200L+ZD6N-S150
• $1,224
8” L series valve with manual gear operator ductile iron, 200 psi close-off, Cv 3136
F6250L+ZD6N-S150
• $1,976
10” L series valve with manual gear operator ductile iron, 200 psi close-off, Cv 5340
F6300L+ZD6N-S150
• $2,264
12” L series valve with manual gear operator ductile iron, 200 psi close-off, Cv 5340
F6350HD+GW04
• $3,090
14” HD series valve with manual gear operator ductile iron, 150 psi close-off, Cv 11917
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

F6400HD+GW05
• $5,263
16” HD series valve with manual gear operator ductile iron, 150 psi close-off, Cv 16388
F6450HD+GW06
• $6,342
18” HD series valve with manual gear operator ductile iron, 150 psi close-off, Cv 21705
All prices are in US Dollars (USD)

F6500HD+GW07
• $9,109
20” HD series valve with manual gear operator ductile iron, 150 psi close-off, Cv 27908

BUTTERFLY VALVES

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

16-31
Manual Handles and Gear Operators
For SHP Series Butterfly Valves

VALVE
MANUAL HANDLES 150SHP LIST PRICE
F650-150SHP+HND05
• $2,621
2” SHP series valve with manual handle cast steel, ANSI 150 close-off limitations, Cv 102
F665-150SHP+HND05
• $2,695
2½” SHP series valve with manual handle cast steel, ANSI 150 close-off limitations, Cv 146
F680-150SHP+HND06
• $2,752
3” SHP series valve with manual handle cast steel, ANSI 150 close-off limitations, Cv 228
F6100-150SHP+HND06
• $2,933
4” SHP series valve with manual handle cast steel, ANSI 150 close-off limitations, Cv 451
F6125-150SHP+HND07
• $4,709
5” SHP series valve with manual handle cast steel, ANSI 150 close-off limitations, Cv 714
F6150-150SHP+HND07
• $4,301
6” SHP series valve with manual handle cast steel, ANSI 150 close-off limitations, Cv 1103
GEAR OPERATORS
F650-150SHP+GW10
• $3,606
2” SHP series valve with manual gear operator cast steel, ANSI 150 close-off limitations, Cv 102
F665-150SHP+GW10
• $3,687
2½” SHP series valve with manual gear operator cast steel, ANSI 150 close-off limitations, Cv 146
F680-150SHP+GW11
• $3,742
3” SHP series valve with manual gear operator cast steel, ANSI 150 close-off limitations, Cv 228
F6100-150SHP+GW11
• $3,857
4” SHP series valve with manual gear operator cast steel, ANSI 150 close-off limitations, Cv 451
F6125-150SHP+GW12
• $5,311
5” SHP series valve with manual gear operator cast steel, ANSI 150 close-off limitations, Cv 714
F6150-150SHP+GW12
• $5,391
6” SHP series valve with manual gear operator cast steel, ANSI 150 close-off limitations, Cv 1103
F6200-150SHP+GW13
• $6,377
8” SHP series valve with manual gear operator cast steel, ANSI 150 close-off limitations, Cv 2064
F6250-150SHP+GW15
• $9,486
10” SHP series valve with manual gear operator cast steel, ANSI 150 close-off limitations, Cv 3517
F6300-150SHP+GW17
• $12,493
12” SHP series valve with manual gear operator cast steel, ANSI 150 close-off limitations, Cv 4837
F6350-150SHP+GW19
• $16,517
14” SHP series valve with manual gear operator cast steel, ANSI 150 close-off limitations, Cv 6857

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


F6400-150SHP+GW21
• $23,443
16” SHP series valve with manual gear operator cast steel, ANSI 150 close-off limitations, Cv 9287
F6450-150SHP+GW23*
• $27,329
18” SHP series valve with manual gear operator cast steel, ANSI 150 close-off limitations, Cv 11500

All prices are in US Dollars (USD)


*Call Customer Service at 1-800-543-9038 for product availability. Longer lead times may apply.
BUTTERFLY VALVES

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

16-32
Manual Handles and Gear Operators
For SHP Series Butterfly Valves

VALVE
MANUAL HANDLES 300SHP LIST PRICE
F650-300SHP+HND05
• $3,089
2” SHP series valve with manual handle cast steel, ANSI 300 close-off limitations, Cv 100
F665-300SHP+HND05
• $3,110
2½” SHP series valve with manual handle cast steel, ANSI 300 close-off limitations, Cv 143
F680-300SHP+HND06
• $2,859
3” SHP series valve with manual handle cast steel, ANSI 300 close-off limitations, Cv 223
F6100-300SHP+HND06
• $3,060
4” SHP series valve with manual handle cast steel, ANSI 300 close-off limitations, Cv 435

F6125-300SHP+HND07
• $5,343
5” SHP series valve with manual handle cast steel, ANSI 300 close-off limitations, Cv 688

GEAR OPERATORS
F650-300SHP+GW10
• $3,804
2” SHP series valve with manual gear operator cast steel, ANSI 300 close-off limitations, Cv 100
F665-300SHP+GW10
• $3,825
2½” SHP series valve with manual gear operator cast steel, ANSI 300 close-off limitations, Cv 143
F680-300SHP+GW11
• $3,574
3” SHP series valve with manual gear operator cast steel, ANSI 300 close-off limitations, Cv 223
F6100-300SHP+GW11
• $3,770
4” SHP series valve with manual gear operator cast steel, ANSI 300 close-off limitations, Cv 435
F6125-300SHP+GW12
• $6,041
5” SHP series valve with manual gear operator cast steel, ANSI 300 close-off limitations, Cv 688
F6150-300SHP+GW13
• $5,021
6” SHP series valve with manual gear operator cast steel, ANSI 300 close-off limitations, Cv 1041
F6200-300SHP+GW14
• $6,687
8” SHP series valve with manual gear operator cast steel, ANSI 300 close-off limitations, Cv 1911
F6250-300SHP+GW16
• $11,089
10” SHP series valve with manual gear operator cast steel, ANSI 300 close-off limitations, Cv 3194
F6300-300SHP+GW18
• $14,644
12” SHP series valve with manual gear operator cast steel, ANSI 300 close-off limitations, Cv 4428
F6350-300SHP+GW20*
• $25,878
14” SHP series valve with manual gear operator cast steel, ANSI 300 close-off limitations, Cv 5702
F6400-300SHP+GW22*
• $30,582
16” SHP series valve with manual gear operator cast steel, ANSI 300 close-off limitations, Cv 8243
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

*Call Customer Service at 1-800-543-9038 for product availability. Longer lead times may apply.
All prices are in US Dollars (USD)

BUTTERFLY VALVES

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

16-33
Small Devices,
Big Impact

Commissioning at Your Fingertips


Easily commission and troubleshoot actuators with your smartphone. NFC allows
assisted configuration by a smartphone, even if the actuator is not connected to power.

CESIM. Small Devices, Big Impact.


Comfort | Energy Efficiency | Safety | Installation | Maintenance

Find out more


belimo.us/cesim
17
PIPE PACKAGES
Fast Delivery and Ease
of Installation
• Easy configuration with Energy Valve, ePIV,
PIQCV, QCV, CCV and zone valves minimize
field pipe connections for quick installation.
• Factory assembled and leak tested for
reliability and maintenance-free operation.
• More package options with components up
to 2” are available within SelectPro offering
simple solutions to your unique requirements.

Aaron Nobel, Product Specialist


Pipe Package Nomenclature

P2 111 1213 1211 2


Pipe Package Union Isolation Valve / Strainer / Isolation Valve Hose
P = Pipe Package Valve Size Manual Balance Valve Valve Size Diameter & Length
Valve Type 1 = ½” Valve Size 1 = ½” 1 = ½” (12” length)
2 = 2-way CCV 2 = ¾” 1 = ½” 2 = ¾” 2 = ½” (24” length)
3 = 3-way CCV 3 = 1” 2 = ¾” 3 = 1” 3 = ¾” (12” length)
E = ePIV / EV 4 = 1” to ¾” 3 = 1” 4 = 1” to ¾” 4 = ¾” (24” length)
P = PIQCV 5 = ¾” to ½” 4 = 1” to ¾” 5 = ¾” to ½” 5 = 1” (12” length)
Q = QCV A = 1½” 5 = ¾” to ½” A = 1½” 6 = 1” (24” length)
Z = Zone B = 1¼” A = 1½” B = 1¼” 7 = ½” (18” length)
Options C = 2” B = 1¼” C = 2” 8 = ¾” (18” length)
S = Supply Side D = 1¼” to 1” C = 2” D = 1¼” to 1” 9 = 1” (18” length)
Package E = 1½” to 1¼” D = 1¼” to 1” E = 1½” to 1¼” A = 1¼” (18” length)
X = Extension F = 2” to 1½” E = 1½” to 1¼” F = 2” to 1½” H = 1¼” (24” length)
Package G = 1” to ½” F = 2” to 1½” G = 1” to ½” B = 1¼” (36” length)
H = 1¼” to ¾” G = 1” to ½” H = 1¼” to ¾” C = 1½” (18” length)
J = 1½” to 1” H = 1¼” to ¾” J = 1½” to 1” D = 1½” (24” length)
K = 2” to 1¼” J = 1½” to 1” K = 2” to 1¼” E = 1½” (36” length)
Body End K = 2” to 1¼” Body End F = 2” (24” length)
1 = Female NPT Body End 1 = Female NPT G = 2” (36” length)
2 = Copper Sweat 1 = Female NPT 2 = Copper Sweat
Configuration 2 = Copper Sweat Configuration
1= Standard Configuration 1 = Standard
Tailpiece End 1 = Standard Tailpiece End (Strainer Option)
Male NPT Only Tailpiece End 1 = Female NPT
Male NPT Only 2 = Copper Sweat
3 = Male NPT
Tailpiece End
(Isolation Valve Option)
0 = Select “0“ for Isolation Valve
Option
Male NPT Only

Please refer to typical Pipe Package layouts on pages prior to ordering. Nomenclature chart does not include all options or
press connection types. Manual Balance Valves require flow consideration for proper sizing. Download Select-Pro software for complete options and
available configurations.

Note: Pipe package smart code does not include the Belimo control valve in the price.
Pipe Package Component Pricing

PIPE PACKAGES
ISOLATION ISOLATION MANUAL BALANCE
UNION UNION MANUAL BALANCE VALVE
PART NUMBER VALVE PART NUMBER VALVE PART NUMBER VALVE
BODY x TAIL LIST PRICE BODY x TAIL*
BODY x TAIL LIST PRICE LIST PRICE
½" x ½" PPU111 $60 ½" x ½" PPV1110 $106 ½" x ½" (Cv 1.30, 0.48 - 1.21 GPM) PPL1111 $179
¾" x ¾" PPU211 $68 ¾" x ¾" PPV2110 $121 ½" x ½" (Cv 2.65, 0.89 - 2.47 GPM) PPL1112 $179
1" x 1" PPU311 $90 1" x 1" PPV3110 $181 ½" x ½" (Cv 7.00, 2.22 - 6.60 GPM) PPL1113 $179
1" x ¾" PPU411 $90 1" x ¾" PPV4110 $181 ¾" x ¾" (Cv 1.30, 0.48 - 1.21 GPM) PPL2111 $184
¾" x ½" PPU511 $68 ¾" x ½" PPV5110 $122 ¾" x ¾" (Cv 2.65, 0.89 - 2.47 GPM) PPL2112 $184
1½" x 1½" PPUA11 $180 1½" x 1½" PPVA110 $531 ¾" x ¾" (Cv 7.00, 2.22 - 6.60 GPM) PPL2113 $184
1¼" x 1¼" PPUB11 $129 1¼" x 1¼" PPVB110 $413 1" x 1" (Cv 7.00, 2.6 - 6.60 GPM) PPL3114 $278
2" x 2" PPUC11 $262 2" x 2" PPVC110 $718 1" x 1" (Cv 17.6, 5.5 - 16.5 GPM) PPL3115 $278
1¼" x 1" PPUD11 $129 1¼" x 1" PPVD110 $413 1" x ¾" (Cv 2.65, 0.89 - 2.47 GPM) PPL4114 $278
1½" x 1¼" PPUE11 $180 1½" x 1¼" PPVE110 $531 1" x ¾" (Cv 3.61, 1.56 - 3.36 GPM) PPL4115 $184
2" x 1½" PPUF11 $262 2" x 1½" PPVF110 $718 1" x ¾" (Cv 7.05, 2.22 - 6.60 GPM) PPL5111 $184
1" x ½" PPUG11 $90 1" x ½" PPVG110 $181 1" x ¾" (Cv 17.6, 5.50 - 16.5 GPM) PPL5112 $184
1¼" to ¾" PPUH11 $129 1¼" to ¾" PPVH110 $413 ¾" x ½" (Cv 1.30, 0.48 - 1.21 GPM) PPL5113 $184
1½" x 1" PPUJ11 $180 1½" x 1" PPVJ110 $531 1½" x 1½" (Cv 57.0, 12.8 - 38.0 GPM) PPLA11B $617
2" x 1¼" PPUK11 $262 2" x 1¼" PPVK110 $718 1¼" x 1¼" (Cv 34.0, 10.6 - 31.8 GPM) PPLB11A $278
2" x 2" (Cv 57.0, 18.0 - 38.0 GPM) PPLC11C $674
2" x 2" (Cv 88, 30.0 - 88.0 GPM) PPLC11D $674
1¼" x 1" (Cv 17.6, 5.5 - 16.5 GPM) PPLD114 $409
1½" x 1¼" (Cv 34.0, 10.6 - 31.8 GPM) PPLE11B $493
Characterized Control Valve
2" x 1½" (Cv 57.0, 12.8 - 38.0 GPM) PPLF11C $674
1" x ½" (Cv 7.05, 2.6 - 6.6 GPM) PPLG114 $278
1" x ½" (Cv 11.4, 4.0 - 11 GPM) PPLG115 $278
1¾" x ¾" (Cv 11.4, 4.0 - 11 GPM) PPLH11A $510
1½" x 1" (Cv 17.6, 5.5 - 16.5 GPM) PPLJ11B $494
2" x 1¼" (Cv 34.0, 10.6 - 31.8 GPM) PPLK11C $674
*Referenced flow values are based on 10”-90” Dp range at 2 ft. head.
Extra Piping Required
Not Supplied
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.
All prices are in US Dollars (USD)

STRAINER STRAINER HOSE (1)


PART NUMBER HOSE PART NUMBER
BODY x TAIL LIST PRICE LIST PRICE
½" x ½" PPS1111 $144 ½" (12" length) PHOSE1 $46
¾" x ¾" PPS2111 $176 ½" (24" length) PHOSE2 $58
1" x 1" PPS3111 $195 ¾" (12" length) PHOSE3 $73
1" x ¾" PPS4111 $195 ¾" (24" length) PHOSE4 $94
¾" x ½" PPS5111 $176 1" (12" length) PHOSE5 $139
1½" x 1½" PPSA111 $357 1" (24" length) PHOSE6 $161
1¼" x 1¼" PPSB111 $319 ½" (18" length) PHOSE1C $58
2" x 2" PPSC111 $548 ¾" (18" length) PHOSE3C $91
1¼" x 1" PPSD111 $319 1" (18" length) PHOSE5C $164
1½" x 1¼" PPSE111 $357 1¼" (18" length) PHOSEAA $249
2" x 1½" PPSF111 $548 1¼" (24" length) PHOSEAB $276
1" x ½" PPSG111 $195 1¼" (36" length) PHOSEAC $323
1¼" x ¾" PPSH111 $319 1½" (18" length) PHOSEBA $355
1½" x 1" PPSJ111 $357 1½"(24" length) PHOSEBB $392
2" x 1¼" PPSK111 $548 1½" (36" length) PHOSEBC $495
2" (24" length) PHOSECA $758
2" (36" length) PHOSECB $882
Add price for Isolation Bypass Valve for 3-way CCV Packages. Bypass Valve is not shown in the reorder number.
Example: A ½" 3-way CCV, will get a ½" Isolation Valve for the Bypass Port. The adder for the Isolation Valve in this example is $106 List Price.

F-NPT configurations shown above. For complete selection of all available connection types including press and sweat, refer to Select-Pro software.
1 ¼”- 2” components, components without P/T ports, components with extentions, double reduction, and press fit connections have increased lead time.
Please Note: For return policy, refer to Piping Package section in Terms and Conditions.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

17-1
Pipe Packages for 2-way Electronic Pressure Independent Valves (ePIV)
PIPE PACKAGES

and Energy Valves (EV)



2-way ePIV/EV (½” to 2”) Return Side
Package (Standard)
air vent
RETURN  Union with integral 5 X DN tail
5x DN
 Belimo Valve and Actuator (Not included in
Smart Code or List Price)
  Isolation Valve
COIL
COIL

   Strainer or Isolation Valve (Strainer shown)


 Optional hoses are available
SUPPLY Supply side packages feature the Belimo control
valve on the supply side of the coil and the above
components arranged in a supply configuration.
 Refer to the SelectPro software for supply side
configurations.

Union Technical Specifications Isolation Valve Technical Specifications


Service chilled or hot water, 60% glycol Service chilled or hot water, 60% glycol
Sizes ½”, ¾”, 1”, 1¼”, 1½”, 2” Sizes ½”, ¾”, 1”, 1¼”, 1½”, 2”
Materials: Materials:
Body forged brass Body forged brass
Union nut forged brass Gland nut extruded brass
forged brass with red brass tail Ball chrome plated/hot forged brass
Tailpiece
extension Stem extruded brass
O-ring EPDM Union nut forged brass
Readout port body & cap extruded brass Tailpiece forged brass
Readout port seal Nordel Seats virgin PTFE
Pressure/temperature ratings: Packing virgin PTFE
½” to 2” 600 psi Stem o-rings Viton
Component temperature 250°F maximum Readout port body & cap extruded brass
14°F to 250°F [-10°C to 120°C] Readout port seal Nordel
Media temperature range 39°F [4°C] on P2200S-1000/ Pressure/temperature ratings:
EV200S-1000

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


½” to ¾” 600 psi
1” to 2” 500 psi
Component temperature 300°F maximum
14°F to 250°F [-10°C to 120°C]
Media temperature range 39°F [4°C] on P2200S-1000/
EV200S-1000

All prices are in US Dollars (USD)


Leakage 0%
Strainer Technical Specifications
Service chilled or hot water, 60% glycol Hose Technical Specifications
Sizes ½”, ¾”, 1”, 1¼”, 1½”, 2” External braiding stainless steel AISI 304
Materials: Crimping ferrules stainless steel AISI 304
Body forged brass Connectors machined brass
Union nut forged brass Fiber gasket BA-U fiber washer
Ball chrome plated/forged brass Core formulated EPDM
Stem & gland nut forged brass Operating & burst pressure rating:
Tailpiece forged brass 375 psi operating
½”
Seals & packing PTFE 1500 psi burst pressure
Stem o-rings Viton 300 psi operating
¾”
Strainer screen 304 stainless steel /20 mesh standard 1200 psi burst pressure
Readout port body & cap extruded brass 225 psi operating
1”
Readout port seal Nordel 900 psi burst pressure
Pressure/temperature ratings: 200 psi operating
1¼”
½” to 2” 600 psi 800 psi burst pressure
Component temperature 325°F maximum 175 psi operating
1½”
14°F to 250°F [-10°C to 120°C] 600 psi burst pressure
Media temperature range 39°F [4°C] on P2200S-1000/ 150 psi operating
EV200S-1000 2”
500 burst pressure
Leakage 0% -5°F to +230°F [-20°C to +110°C]
Component temperature less than 41°F with use of glycol
additive.
Note: Media temperature may be limited by the hose rating

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

17-2
Pipe Packages for 2-way Electronic Pressure Independent Valves (ePIV)

PIPE PACKAGES
and Energy Valves (EV)

ISOLATION
PIPE PACKAGE SMARTCODE (EPIV/EV) UNION STRAINER
VALVE
Pipe Package Part # Valve Nominal Size LIST PRICE
Body End/ Body End/ Body End/
(2-way EPIV/EV)
Inches DN [mm] Tailpiece End Tailpiece End Tailpiece End
without Hose
PE 11C 1110 1111 0 ½ 15 F-NPT/M-NPT F-NPT/M-NPT F-NPT/F-NPT $346
PE 11C 1210 1212 0 ½ 15 F-NPT/M-NPT Sweat/M-NPT Sweat/Sweat $346
PE 21C 2110 2111 0 ¾ 20 F-NPT/M-NPT F-NPT/M-NPT F-NPT/F-NPT $419
PE 21C 2210 2212 0 ¾ 20 F-NPT/M-NPT Sweat/M-NPT Sweat/Sweat $420
PE 31C 3110 3111 0 1 25 F-NPT/M-NPT F-NPT/M-NPT F-NPT/F-NPT $545
PE 31C 3210 3212 0 1 25 F-NPT/M-NPT Sweat/M-NPT Sweat/Sweat $545

ISOLATION
PIPE PACKAGE SMARTCODE (EPIV/EV) UNION STRAINER
VALVE
Pipe Package Part # Valve Nominal Size LIST PRICE
COMPONENT ORDER NOMENCLATURE Body End/ Body End/ Body End/
(2-way EPIV/EV)
EXAMPLE: Inches DN [mm] Tailpiece End Tailpiece End Tailpiece End
21C 2110 2111 3 with 12” Hose
PE PE 11C 1110 1111 1 ½ 15 F-NPT/M-NPT F-NPT/M-NPT F-NPT/F-NPT $437
Union Isolation Strainer Hose PE 11C 1210 1211 1 ½ 15 F-NPT/M-NPT Sweat/M-NPT Sweat/F-NPT $437
PPU21C PPV2110 PPS2111 PHOSE3
PE 21C 2110 2111 3 ¾ 20 F-NPT/M-NPT F-NPT/M-NPT F-NPT/F-NPT $564
PE 21C 2210 2211 3 ¾ 20 F-NPT/M-NPT Sweat/M-NPT Sweat/F-NPT $566
PE 31C 3110 3111 5 1 25 F-NPT/M-NPT F-NPT/M-NPT F-NPT/F-NPT $823
PE 31C 3210 3211 5 1 25 F-NPT/M-NPT Sweat/M-NPT Sweat/F-NPT $823

ISOLATION
PIPE PACKAGE SMARTCODE (EPIV/EV) UNION STRAINER
VALVE
Pipe Package Part # Valve Nominal Size LIST PRICE
Body End/ Body End/ Body End/
(2-way EPIV/EV)
Inches DN [mm] Tailpiece End Tailpiece End Tailpiece End
with 24” hose
PE 11C 1110 1111 2 ½ 15 F-NPT/M-NPT F-NPT/M-NPT F-NPT/F-NPT $461
PE 11C 1210 1211 2 ½ 15 F-NPT/M-NPT Sweat/M-NPT Sweat/F-NPT $461
PE 21C 2110 2111 4 ¾ 20 F-NPT/M-NPT F-NPT/M-NPT F-NPT/F-NPT $607
PE 21C 2210 2211 4 ¾ 20 F-NPT/M-NPT Sweat/M-NPT Sweat/F-NPT $608
PE 31C 3110 3111 6 1 25 F-NPT/M-NPT F-NPT/M-NPT F-NPT/F-NPT $867
PE 31C 3210 3211 6 1 25 F-NPT/M-NPT Sweat/M-NPT Sweat/F-NPT $867
All combinations of reorder numbers are not reflected above. Please use the nomenclature or download the SelectPro
software at www.belimo.us to configure other possible combinations.

Please Note: For return policy, refer to Piping Package section in Terms and Conditions.
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.
All prices are in US Dollars (USD)

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

17-3
Pipe Packages for 2-way ZoneTight Pressure Independent Zone Valves (PIQCV)
PIPE PACKAGES

2-way PIQCV (½” to ¾”) Return Side Package


 (Standard)
air vent
RETURN
 Union
 Belimo Valve and Actuator (Not included in Smart
Code or List Price)
 Isolation Valve
 
COIL
COIL

 Strainer or Isolation Valve (Strainer shown)


  Optional hoses are available
Supply side packages feature the Belimo control valve on
the supply side of the coil and the above components
SUPPLY
arranged in a supply configuration. Refer to the SelectPro
software for supply side configurations.

Union Technical Specifications Isolation Valve Technical Specifications


Service chilled or hot water, 60% glycol Service chilled or hot water, 60% glycol
Sizes ½”, ¾” Sizes ½”, ¾”
Materials: Materials:
Body forged brass Body forged brass
Union nut forged brass Gland nut extruded brass
Tailpiece forged brass Ball chrome plated/hot forged brass
O-ring EPDM Stem extruded brass
Readout port body & cap extruded brass Union nut forged brass
Readout port seal Nordel Tailpiece forged brass
Pressure/temperature ratings: Seats virgin PTFE
½” to ¾” 600 psi Packing virgin PTFE
Component temperature 250°F maximum Stem o-rings Viton
Media temperature range 36°F to 212°F [2°C to 100°C] Readout port body & cap extruded brass
Readout port seal Nordel
Pressure/temperature ratings:

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


½” to ¾” 600 psi
Component temperature 300°F maximum
Media temperature range 36°F to 212°F [2°C to 100°C]
Leakage 0%

All prices are in US Dollars (USD)


Strainer Technical Specifications Hose Technical Specifications
Service chilled or hot water, 60% glycol External braiding stainless steel AISI 304
Sizes ½”, ¾” Crimping ferrules stainless steel AISI 304
Materials: Connectors machined brass
Body forged brass Fiber gasket BA-U fiber washer
Union nut forged brass Core formulated EPDM
Ball chrome plated/forged brass Operating & burst pressure rating:
Stem & gland nut forged brass 375 psi operating
½”
Tailpiece forged brass 1500 psi burst pressure
Seals & packing PTFE 300 psi operating
¾”
Stem o-rings Viton 1200 psi burst pressure
Strainer screen 304 stainless steel /20 mesh standard -5°F to +230°F [-20°C to +110°C]
Readout port body & cap extruded brass Component temperature less than 41°F with use of glycol
Readout port seal Nordel additive.
Pressure/temperature ratings: Note: Media temperature may be limited by the hose rating
½” to ¾” 600 psi
Component temperature 325°F maximum
Media temperature range 36°F to 212°F [2°C to 100°C]
Leakage 0%

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

17-4
Pipe Packages for 2-way ZoneTight Pressure Independent Zone Valves (PIQCV)

PIPE PACKAGES
ISOLATION
PIPE PACKAGE SMARTCODE (PIQCV) UNION STRAINER
VALVE
LIST PRICE
Pipe Package Part # Valve Nominal Size Body End/ Body End/ Body End/
(2-way PIQCV) without Hose Inches DN [mm] Tailpiece End Tailpiece End Tailpiece End
PP 111 1110 1111 0 ½ 15 F-NPT/M-NPT F-NPT/M-NPT F-NPT/F-NPT $309
PP 121 1210 1212 0 ½ 15 Sweat/M-NPT Sweat/M-NPT Sweat/Sweat $309
PP 131 1110 1113 0 ½ 15 M-NPT/M-NPT F-NPT/M-NPT F-NPT/M-NPT $309
PP 131 1210 1213 0 ½ 15 M-NPT/M-NPT Sweat/M-NPT Sweat/M-NPT $309
PP 211 2110 2111 0 ¾ 20 F-NPT/M-NPT F-NPT/M-NPT F-NPT/F-NPT $365
PP 221 2210 2212 0 ¾ 20 Sweat/M-NPT Sweat/M-NPT Sweat/Sweat $366
PP 231 2110 2113 0 ¾ 20 M-NPT/M-NPT F-NPT/M-NPT F-NPT/M-NPT $365
PP 231 2210 2213 0 ¾ 20 M-NPT/M-NPT Sweat/M-NPT Sweat/M-NPT $366

ISOLATION
PIPE PACKAGE SMARTCODE (PIQCV) UNION STRAINER
VALVE
COMPONENT ORDER NOMENCLATURE LIST PRICE
Pipe Package Part # Valve Nominal Size Body End/ Body End/ Body End/
EXAMPLE:
211 2110 2111 3 (2-way PIQCV) with 12” Hose Inches DN [mm] Tailpiece End Tailpiece End Tailpiece End
PP
Union Isolation Strainer Hose PP 111 1110 1111 1 ½ 15 F-NPT/M-NPT F-NPT/M-NPT F-NPT/F-NPT $392
PPU211 PPV2110 PPS2111 PHOSE3 PP 111 1210 1211 1 ½ 15 F-NPT/M-NPT Sweat/M-NPT Sweat/F-NPT $392
PP 211 2110 2111 3 ¾ 20 F-NPT/M-NPT F-NPT/M-NPT F-NPT/F-NPT $510
PP 211 2210 2211 3 ¾ 20 F-NPT/M-NPT Sweat/M-NPT Sweat/F-NPT $511

ISOLATION
PIPE PACKAGE SMARTCODE (PIQCV) UNION STRAINER
VALVE
LIST PRICE
Pipe Package Part # Valve Nominal Size Body End/ Body End/ Body End/
(2-way PIQCV) with 24” hose Inches DN [mm] Tailpiece End Tailpiece End Tailpiece End
PP 111 1110 1111 2 ½ 15 F-NPT/M-NPT F-NPT/M-NPT F-NPT/F-NPT $425
PP 111 1210 1211 2 ½ 15 F-NPT/M-NPT Sweat/M-NPT Sweat/F-NPT $425
PP 211 2110 2111 4 ¾ 20 F-NPT/M-NPT F-NPT/M-NPT F-NPT/F-NPT $553
PP 211 2210 2211 4 ¾ 20 F-NPT/M-NPT Sweat/M-NPT Sweat/F-NPT $554
All combinations of reorder numbers are not reflected above. Please use the nomenclature or download the SelectPro
software at www.belimo.us to configure other possible combinations.

Please Note: For return policy, refer to Piping Package section in Terms and Conditions.

Extension Packages Include:


• Extended handle for Isolation Valve and Strainer
• Extended P/T port for Union, Isolation Valve and
Strainer
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

• Extended air vent for Isolation Valve


All prices are in US Dollars (USD)

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

17-5
Pipe Packages for 2-way ZoneTight Zone Valves (QCV)
PIPE PACKAGES

 air vent 2-way QCV (½” to ¾” NPT)


Return Side Package (Standard)
RETURN
 Union
 Belimo Valve and Actuator (Not included in Smart
Code or List Price)
   Manual Balance Valve
COIL

  Strainer
 Optional hoses are available
Supply side packages feature the Belimo control valve
on the supply side of the coil and the above components
SUPPLY arranged in a supply configuration. Refer to the
SelectPro software for supply side configurations.

Union Technical Specifications Manual Balance Valve Technical Specifications


Service chilled or hot water, 60% glycol Service chilled or hot water, 60% glycol
Sizes ½”, ¾” Sizes ½”, ¾”
Materials: Materials:
Body forged brass Body forged brass
Union nut forged brass Ball chrome plated/forged brass
Tailpiece forged brass Stem extruded brass
O-ring EPDM Union forged brass
Readout port body & cap extruded brass Tailpiece forged brass
Readout port seal Nordel Gland nut extruded brass
Pressure/temperature ratings: Seats & packing virgin PTFE
½” to ¾” 600 psi O-rings Viton
Component temperature 250°F maximum Venturi extruded brass
Media temperature range 36°F to 212°F [2°C to 100°C] Readout port body & cap extruded brass
Readout port seal Nordel
Memory stop forged brass
Pressure/temperature ratings:

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


½” to ¾” 400 psi
Component temperature 300°F maximum
Media temperature range 36°F to 212°F [2°C to 100°C]
Leakage 0%

All prices are in US Dollars (USD)


Strainer Technical Specifications Hose Technical Specifications
Service chilled or hot water, 60% glycol External braiding stainless steel AISI 304
Sizes ½”, ¾” Crimping ferrules stainless steel AISI 304
Materials: Connectors machined brass
Body forged brass Fiber gasket BA-U fiber washer
Union nut forged brass Core formulated EPDM
Ball chrome plated/forged brass Operating & burst pressure rating:
Stem & gland nut forged brass ½” 375 psi operating
Tailpiece forged brass 1500 psi burst pressure
Seals & packing PTFE ¾” 300 psi operating
Stem o-rings Viton 1200 psi burst pressure
Strainer screen 304 stainless steel /20 mesh standard -5°F to +230°F [-20°C to +110°C]
Readout port body & cap extruded brass Component temperature less than 41°F with use of glycol
Readout port seal Nordel additive.
Pressure/temperature ratings: Note: Media temperature may be limited by the hose rating
½” to ¾” 600 psi
Component temperature 325°F maximum
Media temperature range 36°F to 212°F [2°C to 100°C]
Leakage 0%

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

17-6
Pipe Packages for 2-way ZoneTight Zone Valves (QCV)

PIPE PACKAGES
MANUAL
PIPE PACKAGE SMARTCODE (ZONETIGHT) UNION STRAINER
BALANCE VALVE LIST
Pipe Package Model # Valve Nominal Size Body End/ Body End/ Body End/ PRICE
(2-way QCV) without hose Inches DN [mm] Tailpiece End Tailpiece End Tailpiece End
PQ 111 1111 1111 0 ½ 15 F-NPT/M-NPT F-NPT/M-NPT F-NPT/F-NPT $383
PQ 121 1211 1212 0 ½ 15 Sweat/M-NPT Sweat/M-NPT Sweat/Sweat $387
PQ 131 1111 1113 0 ½ 15 M-NPT/M-NPT F-NPT/M-NPT F-NPT/M-NPT $383
PQ 111 1211 1211 0 ½ 15 F-NPT/M-NPT Sweat/M-NPT Sweat/F-NPT $387
PQ 131 1211 1213 0 ½ 15 M-NPT/M-NPT Sweat/M-NPT Sweat/M-NPT $387
PQ 211 2111 2111 0 ¾ 20 F-NPT/M-NPT F-NPT/M-NPT F-NPT/F-NPT $428
PQ 221 2211 2212 0 ¾ 20 Sweat/M-NPT Sweat/M-NPT Sweat/Sweat $428
PQ 231 2111 2113 0 ¾ 20 M-NPT/M-NPT F-NPT/M-NPT F-NPT/M-NPT $428
PQ 211 2211 2211 0 ¾ 20 F-NPT/M-NPT Sweat/M-NPT Sweat/F-NPT $428
COMPONENT ORDER NOMENCLATURE PQ 231 2211 2213 0 ¾ 20 M-NPT/M-NPT Sweat/M-NPT Sweat/M-NPT $428
EXAMPLE: MANUAL
111 1111 1111 0 PIPE PACKAGE SMARTCODE (ZONETIGHT) UNION STRAINER
PQ BALANCE VALVE LIST
Union MBV Strainer No Hose Valve Nominal Size PRICE
Pipe Package Model # Body End/ Body End/ Body End/
PPU111 PPL1111 PPS1111
(2-way QCV) with 12” hose Inches DN [mm] Tailpiece End Tailpiece End Tailpiece End
PQ 111 1111 1111 1 ½ 15 F-NPT/M-NPT F-NPT/M-NPT F-NPT/F-NPT $475
PQ 111 1111 1211 1 ½ 15 F-NPT/M-NPT F-NPT/M-NPT Sweat/F-NPT $475
PQ 111 1211 1111 1 ½ 15 F-NPT/M-NPT Sweat/M-NPT F-NPT/F-NPT $479
PQ 111 1211 1211 1 ½ 15 F-NPT/M-NPT Sweat/M-NPT Sweat/F-NPT $479
PQ 211 2111 2111 3 ¾ 20 F-NPT/M-NPT F-NPT/M-NPT F-NPT/F-NPT $573
PQ 211 2111 2211 3 ¾ 20 F-NPT/M-NPT F-NPT/M-NPT Sweat/F-NPT $573
PQ 211 2211 2111 3 ¾ 20 F-NPT/M-NPT Sweat/M-NPT F-NPT/F-NPT $573
PQ 211 2211 2211 3 ¾ 20 F-NPT/M-NPT Sweat/M-NPT Sweat/F-NPT $573

MANUAL
PIPE PACKAGE SMARTCODE (ZONETIGHT) UNION STRAINER
BALANCE VALVE LIST
Pipe Package Model # Valve Nominal Size Body End/ Body End/ Body End/ PRICE
(2-way QCV) with 24” hose Inches DN [mm] Tailpiece End Tailpiece End Tailpiece End
PQ 111 1111 1111 2 ½ 15 F-NPT/M-NPT F-NPT/M-NPT F-NPT/F-NPT $498
PQ 111 1111 1211 2 ½ 15 F-NPT/M-NPT F-NPT/M-NPT Sweat/F-NPT $498
PQ 111 1211 1111 2 ½ 15 F-NPT/M-NPT Sweat/M-NPT F-NPT/F-NPT $503
PQ 111 1211 1211 2 ½ 15 F-NPT/M-NPT Sweat/M-NPT Sweat/F-NPT $503
PQ 211 2111 2111 4 ¾ 20 F-NPT/M-NPT F-NPT/M-NPT F-NPT/F-NPT $616
PQ 211 2111 2211 4 ¾ 20 F-NPT/M-NPT F-NPT/M-NPT Sweat/F-NPT $616
Extension Packages Include:
PQ 211 2211 2111 4 ¾ 20 F-NPT/M-NPT Sweat/M-NPT F-NPT/F-NPT $616
• Extended handle for Manual Balance Valve,
PQ 211 2211 2211 4 ¾ 20 F-NPT/M-NPT Sweat/M-NPT Sweat/F-NPT $616
Isolation Valve and Strainer
All combinations of reorder numbers are not reflected above. Please use the nomenclature or download the SelectPro
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

• Extended P/T ports for Union, Manual software at www.belimo.us to configure other possible combinations. Reference 17-1 for Manual Balance Valve
Balance Valve, Strainer or Isolation Valve flow ranges.
• Extended air vent for Manual Balance Valve
and Isolation Valve Please Note: For return policy, refer to Piping Package section in Terms and Conditions.
All prices are in US Dollars (USD)

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

17-7
Pipe Packages for 2-way Characterized Control Valves (CCV)
PIPE PACKAGES

2-way CCV (½” to 2”) Return Side Package


air vent (Standard)
 Union
 Belimo Valve and Actuator (Not included in Smart
Code or List Price)
 Manual Balance Valve
 Strainer
   Optional hoses are available
 Supply side packages feature the Belimo control valve on
the supply side of the coil and the above components
arranged in a supply configuration. Refer to the SelectPro
software for supply side configurations.

Union Technical Specifications Manual Balance Valve Technical Specifications


Service chilled or hot water, 60% glycol Service chilled or hot water, 60% glycol
Sizes ½”, ¾”, 1”, 1¼”, 1½”, 2” Sizes ½”, ¾”, 1”, 1¼”, 1½”, 2”
Materials: Materials:
Body forged brass Body forged brass
Union nut forged brass Ball chrome plated/forged brass
Tailpiece forged brass Stem extruded brass
O-ring EPDM Union forged brass
Readout port body & cap extruded brass Tailpiece forged brass
Readout port seal Nordel Gland nut extruded brass
Pressure/temperature ratings: Seats & packing virgin PTFE
½” to 2” 600 psi O-rings viton
Component temperature 250°F maximum Venturi extruded brass
Media temperature range 0°F to 250°F [-18°C to +120°C] Readout port body & cap extruded brass
Readout port seal Nordel
Memory stop forged brass

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


Pressure/temperature ratings:
½” to 2” 400 psi
Component temperature 300°F maximum
Media temperature range 0°F to 250°F [-18°C to +120°C]
Leakage 0%

All prices are in US Dollars (USD)


Strainer Technical Specifications Hose Technical Specifications
Service chilled or hot water, 60% glycol External braiding stainless steel AISI 304
Sizes ½”, ¾”, 1”, 1¼”, 1½”, 2” Crimping ferrules stainless steel AISI 304
Materials: Connectors machined brass
Body forged brass Fiber gasket BA-U fiber washer
Union nut forged brass Core formulated EPDM
Ball chrome plated/forged brass Operating & burst pressure rating:
Stem & gland nut forged brass ½” 375 psi operating
Tailpiece forged brass 1500 psi burst pressure
Seals & packing PTFE ¾” 300 psi operating
Stem o-rings Viton 1200 psi burst pressure
Strainer screen 304 stainless steel /20 mesh standard 1” 225 psi operating
Readout port body & cap extruded brass 900 psi burst pressure
Readout port seal Nordel 1¼” 200 psi operating
Pressure/temperature ratings: 800 psi burst pressure
½” to 2” 600 psi 1½” 175 psi operating
Component temperature 325°F maximum 600 psi burst pressure
Media temperature range 0°F to 250°F [-18°C to +120°C] 2” 150 psi operating
Leakage 0% 500 burst pressure
-5°F to +230°F [-20°C to +110°C]
Component temperature less than 41°F with use of glycol
additive.
Note: Media temperature may be limited by the hose rating

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

17-8
Pipe Packages for 2-way Characterized Control Valves (CCV)

PIPE PACKAGES
MANUAL
PIPE PACKAGE SMARTCODE (CCV) UNION STRAINER
BALANCE VALVE LIST
Pipe Package Model # Valve Nominal Size Body End/ Body End/ Body End/ PRICE
(2-way CCV) without hose Inches DN [mm] Tailpiece End Tailpiece End Tailpiece End
P2 111 1111 1111 0 ½ 15 F-NPT/M-NPT F-NPT/M-NPT F-NPT/F-NPT $383
P2 121 1211 1212 0 ½ 15 Sweat/M-NPT Sweat/M-NPT Sweat/Sweat $387
P2 131 1111 1113 0 ½ 15 M-NPT/M-NPT F-NPT/M-NPT F-NPT/M-NPT $383
P2 111 1211 1211 0 ½ 15 F-NPT/M-NPT Sweat/M-NPT Sweat/F-NPT $387
P2 131 1211 1213 0 ½ 15 M-NPT/M-NPT Sweat/M-NPT Sweat/M-NPT $387
P2 211 2111 2111 0 ¾ 20 F-NPT/M-NPT F-NPT/M-NPT F-NPT/F-NPT $428
P2 221 2211 2212 0 ¾ 20 Sweat/M-NPT Sweat/M-NPT Sweat/Sweat $428
P2 231 2111 2113 0 ¾ 20 M-NPT/M-NPT F-NPT/M-NPT F-NPT/M-NPT $428
P2 211 2211 2211 0 ¾ 20 F-NPT/M-NPT Sweat/M-NPT Sweat/F-NPT $428
P2 231 2211 2213 0 ¾ 20 M-NPT/M-NPT Sweat/M-NPT Sweat/M-NPT $428
P2 311 3114 3111 0 1 25 F-NPT/M-NPT F-NPT/M-NPT F-NPT/F-NPT $563
P2 321 3214 3212 0 1 25 Sweat/M-NPT Sweat/M-NPT Sweat/Sweat $563
P2 331 3114 3113 0 1 25 M-NPT/M-NPT F-NPT/M-NPT F-NPT/M-NPT $563
COMPONENT ORDER NOMENCLATURE
P2 311 3214 3211 0 1 25 F-NPT/M-NPT Sweat/M-NPT Sweat/F-NPT $563
EXAMPLE:
111 1111 1111 1 P2 331 3214 3213 0 1 25 M-NPT/M-NPT Sweat/M-NPT Sweat/M-NPT $563
P2
Union MBV Strainer Hose MANUAL
PPU111 PPL1111 PPS1111 PHOSE1 PIPE PACKAGE SMARTCODE (CCV) UNION STRAINER
BALANCE VALVE LIST
Pipe Package Model # Valve Nominal Size Body End/ Body End/ Body End/ PRICE
(2-way CCV) with 12” hose Inches DN [mm] Tailpiece End Tailpiece End Tailpiece End
P2 111 1111 1111 1 ½ 15 F-NPT/M-NPT F-NPT/M-NPT F-NPT/F-NPT $475
P2 111 1111 1211 1 ½ 15 F-NPT/M-NPT F-NPT/M-NPT Sweat/F-NPT $475
P2 111 1211 1111 1 ½ 15 F-NPT/M-NPT Sweat/M-NPT F-NPT/F-NPT $479
P2 111 1211 1211 1 ½ 15 F-NPT/M-NPT Sweat/M-NPT Sweat/F-NPT $479
P2 211 2111 2111 3 ¾ 20 F-NPT/M-NPT F-NPT/M-NPT F-NPT/F-NPT $573
P2 211 2111 2211 3 ¾ 20 F-NPT/M-NPT F-NPT/M-NPT Sweat/F-NPT $573
P2 211 2211 2111 3 ¾ 20 F-NPT/M-NPT Sweat/M-NPT F-NPT/F-NPT $573
P2 211 2211 2211 3 ¾ 20 F-NPT/M-NPT Sweat/M-NPT Sweat/F-NPT $573
P2 311 3114 3111 5 1 25 F-NPT/M-NPT F-NPT/M-NPT F-NPT/F-NPT $841
P2 311 3114 3211 5 1 25 F-NPT/M-NPT F-NPT/M-NPT Sweat/F-NPT $841
P2 311 3214 3111 5 1 25 F-NPT/M-NPT Sweat/M-NPT F-NPT/F-NPT $841
P2 311 3214 3211 5 1 25 F-NPT/M-NPT Sweat/M-NPT Sweat/F-NPT $841

MANUAL
PIPE PACKAGE SMARTCODE (CCV) UNION STRAINER
BALANCE VALVE LIST
Extension Packages Include: Pipe Package Model # Valve Nominal Size Body End/ Body End/ Body End/ PRICE
• Extended handle for Manual Balance Valve, (2-way CCV) with 24” hose Inches DN [mm] Tailpiece End Tailpiece End Tailpiece End
Isolation Valve and Strainer P2 111 1111 1111 2 ½ 15 F-NPT/M-NPT F-NPT/M-NPT F-NPT/F-NPT $498
• Extended P/T ports for Union, Manual
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

P2 111 1111 1211 2 ½ 15 F-NPT/M-NPT F-NPT/M-NPT Sweat/F-NPT $498


Balance Valve, Strainer or Isolation Valve P2 111 1211 1111 2 ½ 15 F-NPT/M-NPT Sweat/M-NPT F-NPT/F-NPT $503
• Extended air vent for Manual Balance Valve P2 111 1211 1211 2 ½ 15 F-NPT/M-NPT Sweat/M-NPT Sweat/F-NPT $503
and Isolation Valve P2 211 2111 2111 4 ¾ 20 F-NPT/M-NPT F-NPT/M-NPT F-NPT/F-NPT $616
P2 211 2111 2211 4 ¾ 20 F-NPT/M-NPT F-NPT/M-NPT Sweat/F-NPT $616
All prices are in US Dollars (USD)

P2 211 2211 2111 4 ¾ 20 F-NPT/M-NPT Sweat/M-NPT F-NPT/F-NPT $616


P2 211 2211 2211 4 ¾ 20 F-NPT/M-NPT Sweat/M-NPT Sweat/F-NPT $616
P2 311 3114 3111 6 1 25 F-NPT/M-NPT F-NPT/M-NPT F-NPT/F-NPT $886
P2 311 3114 3211 6 1 25 F-NPT/M-NPT F-NPT/M-NPT Sweat/F-NPT $886
P2 311 3214 3111 6 1 25 F-NPT/M-NPT Sweat/M-NPT F-NPT/F-NPT $886
P2 311 3214 3211 6 1 25 F-NPT/M-NPT Sweat/M-NPT Sweat/F-NPT $886
All combinations of reorder numbers are not reflected above. Please use the nomenclature or download the SelectPro
software at www.belimo.us to configure other possible combinations. Reference 17-1 for Manual Balance Valve
flow ranges.

Please Note: For return policy, refer to Piping Package section in Terms and Conditions.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

17-9
Pipe Packages for 3-way Characterized Control Valves (CCV)
PIPE PACKAGES

 3-way CCV (½” to 2”) Return Side Package


air vent (Standard)
 Union
 Belimo Valve and Actuator (Not included in Smart
Code or List Price)
 Manual Balance Valve
   Strainer
  Isolation Valve

COIL

 Optional hoses are available


*Note: Extra piping for Isolation Valve to CCV and Strainer is
* Extra piping not supplied by Belimo
required (not supplied).
Supply side packages feature the Belimo control valve on
the supply side of the coil and the above components
arranged in a supply configuration. Refer to the SelectPro
software for supply side configurations.

Union Technical Specifications Manual Balance Valve Technical Specifications Strainer Technical Specifications
Service chilled or hot water, 60% Service chilled or hot water, 60% Service chilled or hot water, 60%
glycol glycol glycol
Sizes ½”, ¾”, 1”, 1¼”, 1½”, 2” Sizes ½”, ¾”, 1”, 1¼”, 1½”, 2” Sizes ½”, ¾”, 1”, 1¼”, 1½”, 2”
Materials: Materials: Materials:
Body forged brass Body forged brass Body forged brass
Union nut forged brass Ball chrome plated/forged brass Union nut forged brass
Tailpiece forged brass Stem extruded brass Ball chrome plated/forged brass
O-ring EPDM Union forged brass Stem & gland nut forged brass
Readout port body & cap extruded brass Tailpiece forged brass Tailpiece forged brass
Readout port seal Nordel Gland nut extruded brass Seals & packing PTFE
Pressure/temperature ratings: Seats & packing virgin PTFE Stem o-rings Viton
½” to 2” 600 psi O-rings Viton Strainer screen 304 stainless steel /
Component temperature 250°F maximum Venturi extruded brass 20 mesh standard
0°F to 250°F Readout port body & cap extruded brass Readout port body & cap extruded brass
Media temperature range Readout port seal Nordel
[-18°C to +120°C] Readout port seal Nordel
Memory stop forged brass Pressure/temperature ratings:
Pressure/temperature ratings:

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


½” to 2” 600 psi
½” to 2” 400 psi Component temperature 325°F maximum
Component temperature 300°F maximum 0°F to 250°F
Media temperature range
[-18°C to +120°C]
Media temperature range 0°F to 250°F
[-18°C to +120°C] Leakage 0%
Leakage 0%

All prices are in US Dollars (USD)


Isolation Valve Technical Specifications Hose Technical Specifications
Service chilled or hot water, 60% glycol External braiding stainless steel AISI 304
Sizes ½”, ¾”, 1”, 1¼”, 1½”, 2” Crimping ferrules stainless steel AISI 304
Materials: Connectors machined brass
Body forged brass Fiber gasket BA-U fiber washer
Gland nut extruded brass Core formulated EPDM
Ball chrome plated/hot forged brass Operating & burst pressure rating:
Stem extruded brass ½” 375 psi operating
Union nut forged brass 1500 psi burst pressure
Tailpiece forged brass ¾” 300 psi operating
Seats virgin PTFE 1200 psi burst pressure
Packing virgin PTFE 1” 225 psi operating
Stem o-rings Viton 900 psi burst pressure
Readout port body & cap extruded brass 1¼” 200 psi operating
Readout port seal Nordel 800 psi burst pressure
Pressure/temperature ratings: 1½” 175 psi operating
½” to ¾” 600 psi 600 psi burst pressure
1” to 2” 500 psi 2” 150 psi operating
Component temperature 300°F maximum 500 burst pressure
Media temperature range 0°F to 250°F [-18°C to +120°C] -5°F to +230°F [-20°C to +110°C]
Leakage 0% Component temp. less than 41°F with use of glycol
additive.
Note: Media temperature may be limited by the hose rating

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

17-10
Pipe Packages for 3-way Characterized Control Valves (CCV)

PIPE PACKAGES
MANUAL
PIPE PACKAGE SMARTCODE (CCV) UNION STRAINER
BALANCE VALVE LIST
Pipe Package Model # Valve Nominal Size Body End/ Body End/ Body End/ PRICE
(3-way CCV) without hose Inches DN [mm] Tailpiece End Tailpiece End Tailpiece End
P3 111 1111 1111 0 ½ 15 F-NPT/M-NPT F-NPT/M-NPT F-NPT/F-NPT $489
P3 121 1211 1212 0 ½ 15 Sweat/M-NPT Sweat/M-NPT Sweat/Sweat $493
P3 131 1111 1113 0 ½ 15 M-NPT/M-NPT F-NPT/M-NPT F-NPT/M-NPT $489
P3 111 1211 1211 0 ½ 15 F-NPT/M-NPT Sweat/M-NPT Sweat/F-NPT $493
P3 131 1211 1213 0 ½ 15 M-NPT/M-NPT Sweat/M-NPT Sweat/M-NPT $493
P3 211 2111 2111 0 ¾ 20 F-NPT/M-NPT F-NPT/M-NPT F-NPT/F-NPT $548
P3 221 2211 2212 0 ¾ 20 Sweat/M-NPT Sweat/M-NPT Sweat/Sweat $548
P3 231 2111 2113 0 ¾ 20 M-NPT/M-NPT F-NPT/M-NPT F-NPT/M-NPT $548
P3 211 2211 2211 0 ¾ 20 F-NPT/M-NPT Sweat/M-NPT Sweat/F-NPT $548
P3 231 2211 2213 0 ¾ 20 M-NPT/M-NPT Sweat/M-NPT Sweat/M-NPT $548
P3 311 3114 3111 0 1 25 F-NPT/M-NPT F-NPT/M-NPT F-NPT/F-NPT $745
P3 321 3214 3212 0 1 25 Sweat/M-NPT Sweat/M-NPT Sweat/Sweat $745
P3 331 3114 3113 0 1 25 M-NPT/M-NPT F-NPT/M-NPT F-NPT/M-NPT $745
P3 311 3214 3211 0 1 25 F-NPT/M-NPT Sweat/M-NPT Sweat/F-NPT $745
P3 331 3214 3213 0 1 25 M-NPT/M-NPT Sweat/M-NPT Sweat/M-NPT $745

MANUAL
PIPE PACKAGE SMARTCODE (CCV) UNION STRAINER
COMPONENT ORDER NOMENCLATURE BALANCE VALVE LIST
EXAMPLE: Pipe Package Model # Valve Nominal Size Body End/ Body End/ Body End/ PRICE
311 3114 3111 5
P3 (3-way CCV) with 12” hose Inches DN [mm] Tailpiece End Tailpiece End Tailpiece End
Union MBV Strainer Hose P3 111 1111 1111 1 ½ 15 F-NPT/M-NPT F-NPT/M-NPT F-NPT/F-NPT $580
PPU311 PPL3114 PPS3111 PHOSE5 P3 111 1111 1211 1 ½ 15 F-NPT/M-NPT F-NPT/M-NPT Sweat/F-NPT $580
P3 111 1211 1111 1 ½ 15 F-NPT/M-NPT Sweat/M-NPT F-NPT/F-NPT $585
P3 111 1211 1211 1 ½ 15 F-NPT/M-NPT Sweat/M-NPT Sweat/F-NPT $585
P3 211 2111 2111 3 ¾ 20 F-NPT/M-NPT F-NPT/M-NPT F-NPT/F-NPT $694
P3 211 2111 2211 3 ¾ 20 F-NPT/M-NPT F-NPT/M-NPT Sweat/F-NPT $694
P3 211 2211 2111 3 ¾ 20 F-NPT/M-NPT Sweat/M-NPT F-NPT/F-NPT $694
P3 211 2211 2211 3 ¾ 20 F-NPT/M-NPT Sweat/M-NPT Sweat/F-NPT $694
P3 311 3114 3111 5 1 25 F-NPT/M-NPT F-NPT/M-NPT F-NPT/F-NPT $1,022
P3 311 3114 3211 5 1 25 F-NPT/M-NPT F-NPT/M-NPT Sweat/F-NPT $1,022
P3 311 3214 3111 5 1 25 F-NPT/M-NPT Sweat/M-NPT F-NPT/F-NPT $1,022
P3 311 3214 3211 5 1 25 F-NPT/M-NPT Sweat/M-NPT Sweat/F-NPT $1,022

MANUAL
PIPE PACKAGE SMARTCODE (CCV) UNION STRAINER
BALANCE VALVE LIST
Pipe Package Model # Valve Nominal Size Body End/ Body End/ Body End/ PRICE
(3-way CCV) with 24” hose Inches DN [mm] Tailpiece End Tailpiece End Tailpiece End
Extension Packages Include:
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

P3 111 1111 1111 2 ½ 15 F-NPT/M-NPT F-NPT/M-NPT F-NPT/F-NPT $604


• Extended handle for Manual Balance Valve, P3 111 1111 1211 2 ½ 15 F-NPT/M-NPT F-NPT/M-NPT Sweat/F-NPT $604
Isolation Valve and Strainer P3 111 1211 1111 2 ½ 15 F-NPT/M-NPT Sweat/M-NPT F-NPT/F-NPT $608
• Extended P/T ports for Union, Manual P3 111 1211 1211 2 ½ 15 F-NPT/M-NPT Sweat/M-NPT Sweat/F-NPT $608
Balance Valve, Strainer or Isolation Valve P3 211 2111 2111 4 ¾ 20 F-NPT/M-NPT F-NPT/M-NPT F-NPT/F-NPT $736
• Extended air vent for Manual Balance Valve P3 211 2111 2211 4 ¾ 20 F-NPT/M-NPT F-NPT/M-NPT Sweat/F-NPT $736
All prices are in US Dollars (USD)

and Isolation Valve P3 211 2211 2111 4 ¾ 20 F-NPT/M-NPT Sweat/M-NPT F-NPT/F-NPT $736
P3 211 2211 2211 4 ¾ 20 F-NPT/M-NPT Sweat/M-NPT Sweat/F-NPT $736
P3 311 3114 3111 6 1 25 F-NPT/M-NPT F-NPT/M-NPT F-NPT/F-NPT $1,067
P3 311 3114 3211 6 1 25 F-NPT/M-NPT F-NPT/M-NPT Sweat/F-NPT $1,067
P3 311 3214 3111 6 1 25 F-NPT/M-NPT Sweat/M-NPT F-NPT/F-NPT $1,067
P3 311 3214 3211 6 1 25 F-NPT/M-NPT Sweat/M-NPT Sweat/F-NPT $1,067
All combinations of reorder numbers are not reflected above. Please use the nomenclature or download the SelectPro
software at www.belimo.us to configure other possible combinations. Reference 17-1 for Manual Balance Valve
flow ranges.

Please Note: For return policy, refer to Piping Package section in Terms and Conditions.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

17-11
Pipe Packages for Standard Zone Valves
PIPE PACKAGES

air vent 2-way Zone Valve (½” to 1” NPT)



Return Side Package (Standard)
 Union
 Belimo Valve and Actuator (Not included in Smart
Code or List Price)
 * Zone valve only rated
for 50% glycol   Manual Balance Valve
  Strainer
 Optional hoses are available
Supply side packages feature the Belimo control valve
on the supply side of the coil and the above components
arranged in a supply configuration. Refer to the
SelectPro software for supply side configurations.

Union Technical Specifications Manual Balance Valve Technical Specifications


Service chilled or hot water, 50% glycol Service chilled or hot water, 50% glycol
Sizes ½”, ¾”, 1” Sizes ½”, ¾”, 1”
Materials: Materials:
Body forged brass Body forged brass
Union nut forged brass Ball chrome plated/forged brass
Tailpiece forged brass Stem extruded brass
O-ring EPDM Union forged brass
Readout port body & cap extruded brass Tailpiece forged brass
Readout port seal Nordel Gland nut extruded brass
Pressure/temperature ratings: Seats & packing virgin PTFE
½” to 2” 600 psi O-rings Viton
Component temperature 250°F maximum Venturi extruded brass
Media temperature range 32°F to 212°F [0°C to 100°C] Readout port body & cap extruded brass
Readout port seal Nordel
Memory stop forged brass
Pressure/temperature ratings:

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


½” to 2” 400 psi
Component temperature 300°F maximum
Media temperature range 32°F to 212°F [0°C to 100°C]
Leakage 0%

All prices are in US Dollars (USD)


Strainer Technical Specifications Hose Technical Specifications
Service chilled or hot water, 50% glycol External braiding stainless steel AISI 304
Sizes ½”, ¾”, 1” Crimping ferrules stainless steel AISI 304
Materials: Connectors machined brass
Body forged brass Fiber gasket BA-U fiber washer
Union nut forged brass Core formulated EPDM
Ball chrome plated/forged brass Operating & burst pressure rating:
Stem & gland nut forged brass ½” 375 psi operating
Tailpiece forged brass 1500 psi burst pressure
Seals & packing PTFE ¾” 300 psi operating
Stem o-rings Viton 1200 psi burst pressure
Strainer screen 304 stainless steel /20 mesh standard 1” 225 psi operating
Readout port body & cap extruded brass 900 psi burst pressure
Readout port seal Nordel -5°F to +230°F [-20°C to +110°C]
Pressure/temperature ratings: Component temperature less than 41°F with use of glycol
½” to 2” 600 psi additive.
Component temperature 325°F maximum Note: Media temperature may be limited by the hose rating
Media temperature range 32°F to 212°F [0°C to 100°C]
Leakage 0%

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

17-12
Pipe Packages for Standard Zone Valves

PIPE PACKAGES
MANUAL
PIPE PACKAGE SMARTCODE (ZONE) UNION STRAINER
BALANCE VALVE
LIST
Pipe Package Model # Valve Nominal Size
Body End/ Body End/ Body End/ PRICE
(2-way Zone Valve)
Inches DN [mm] Tailpiece End Tailpiece End Tailpiece End
without hose
PZ 111 1111 1111 0 ½ 15 F-NPT/M-NPT F-NPT/M-NPT F-NPT/F-NPT $383
PZ 121 1211 1212 0 ½ 15 Sweat/M-NPT Sweat/M-NPT Sweat/Sweat $387
PZ 131 1111 1113 0 ½ 15 M-NPT/M-NPT F-NPT/M-NPT F-NPT/M-NPT $383
PZ 111 1211 1211 0 ½ 15 F-NPT/M-NPT Sweat/M-NPT Sweat/F-NPT $387
PZ 131 1211 1213 0 ½ 15 M-NPT/M-NPT Sweat/M-NPT Sweat/M-NPT $387
PZ 211 2111 2111 0 ¾ 20 F-NPT/M-NPT F-NPT/M-NPT F-NPT/F-NPT $428
PZ 221 2211 2212 0 ¾ 20 Sweat/M-NPT Sweat/M-NPT Sweat/Sweat $428
PZ 231 2111 2113 0 ¾ 20 M-NPT/M-NPT F-NPT/M-NPT F-NPT/M-NPT $428
PZ 211 2211 2211 0 ¾ 20 F-NPT/M-NPT Sweat/M-NPT Sweat/F-NPT $428
COMPONENT ORDER NOMENCLATURE
PZ 231 2211 2213 0 ¾ 20 M-NPT/M-NPT Sweat/M-NPT Sweat/M-NPT $428
EXAMPLE:
111 1111 1111 0 PZ 311 3114 3111 0 1 25 F-NPT/M-NPT F-NPT/M-NPT F-NPT/F-NPT $563
PZ
Union MBV Strainer No Hose PZ 321 3214 3212 0 1 25 Sweat/M-NPT Sweat/M-NPT Sweat/Sweat $563
PPU111 PPL1111 PPS1111 PZ 331 3114 3113 0 1 25 M-NPT/M-NPT F-NPT/M-NPT F-NPT/M-NPT $563
PZ 321 3214 3211 0 1 25 F-NPT/M-NPT Sweat/M-NPT Sweat/F-NPT $563
PZ 331 3214 3213 0 1 25 M-NPT/M-NPT Sweat/M-NPT Sweat/M-NPT $563

MANUAL
PIPE PACKAGE SMARTCODE (ZONE) UNION STRAINER
BALANCE VALVE
LIST
Pipe Package Model # Valve Nominal Size
Body End/ Body End/ Body End/ PRICE
(2-way Zone Valve)
Inches DN [mm] Tailpiece End Tailpiece End Tailpiece End
with 12” hose
PZ 111 1111 1111 1 ½ 15 F-NPT/M-NPT F-NPT/M-NPT F-NPT/F-NPT $475
PZ 111 1111 1211 1 ½ 15 F-NPT/M-NPT F-NPT/M-NPT Sweat/F-NPT $475
PZ 111 1211 1111 1 ½ 15 F-NPT/M-NPT Sweat/M-NPT F-NPT/F-NPT $479
PZ 111 1211 1211 1 ½ 15 F-NPT/M-NPT Sweat/M-NPT Sweat/F-NPT $479
PZ 211 2111 2111 3 ¾ 20 F-NPT/M-NPT F-NPT/M-NPT F-NPT/F-NPT $573
PZ 211 2111 2211 3 ¾ 20 F-NPT/M-NPT F-NPT/M-NPT Sweat/F-NPT $573
PZ 211 2211 2111 3 ¾ 20 F-NPT/M-NPT Sweat/M-NPT F-NPT/F-NPT $573
PZ 211 2211 2211 3 ¾ 20 F-NPT/M-NPT Sweat/M-NPT Sweat/F-NPT $573
PZ 311 3114 3111 5 1 25 F-NPT/M-NPT F-NPT/M-NPT F-NPT/F-NPT $841
PZ 311 3114 3211 5 1 25 F-NPT/M-NPT F-NPT/M-NPT Sweat/F-NPT $841
PZ 311 3214 3111 5 1 25 F-NPT/M-NPT Sweat/M-NPT F-NPT/F-NPT $841
Extension Packages Include: PZ 311 3214 3211 5 1 25 F-NPT/M-NPT Sweat/M-NPT Sweat/F-NPT $841
• Extended handle for Manual Balance Valve, MANUAL
Isolation Valve and Strainer PIPE PACKAGE SMARTCODE (ZONE) UNION STRAINER
BALANCE VALVE
LIST
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

• Extended P/T ports for Union, Manual Pipe Package Model # Valve Nominal Size
Body End/ Body End/ Body End/ PRICE
Balance Valve, Strainer or Isolation Valve (2-way Zone Valve)
Inches DN [mm] Tailpiece End Tailpiece End Tailpiece End
• Extended air vent for Manual Balance Valve with 24” hose
and Isolation Valve PZ 111 1111 1111 2 ½ 15 F-NPT/M-NPT F-NPT/M-NPT F-NPT/F-NPT $498
PZ 111 1111 1211 2 ½ 15 F-NPT/M-NPT F-NPT/M-NPT Sweat/F-NPT $498
All prices are in US Dollars (USD)

PZ 111 1211 1111 2 ½ 15 F-NPT/M-NPT Sweat/M-NPT F-NPT/F-NPT $503


PZ 111 1211 1211 2 ½ 15 F-NPT/M-NPT Sweat/M-NPT Sweat/F-NPT $503
PZ 211 2111 2111 4 ¾ 20 F-NPT/M-NPT F-NPT/M-NPT F-NPT/F-NPT $616
PZ 211 2111 2211 4 ¾ 20 F-NPT/M-NPT F-NPT/M-NPT Sweat/F-NPT $616
PZ 211 2211 2111 4 ¾ 20 F-NPT/M-NPT Sweat/M-NPT F-NPT/F-NPT $616
PZ 211 2211 2211 4 ¾ 20 F-NPT/M-NPT Sweat/M-NPT Sweat/F-NPT $616
PZ 311 3114 3111 6 1 25 F-NPT/M-NPT F-NPT/M-NPT F-NPT/F-NPT $886
PZ 311 3114 3211 6 1 25 F-NPT/M-NPT F-NPT/M-NPT Sweat/F-NPT $886
PZ 311 3214 3111 6 1 25 F-NPT/M-NPT Sweat/M-NPT F-NPT/F-NPT $886
PZ 311 3214 3211 6 1 25 F-NPT/M-NPT Sweat/M-NPT Sweat/F-NPT $886
All combinations of reorder numbers are not reflected above. Please use the nomenclature or download the SelectPro
software at www.belimo.us to configure other possible combinations. Reference 17-1 for Manual Balance Valve
flow ranges.

Please Note: For return policy, refer to Piping Package section in Terms and Conditions.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

17-13
Reduce Time, Space,
and Cost

Belimo Pipe Packages


Belimo’s pipe packages incorporate valve assemblies and common piping components to
simplify the contractor’s job by eliminating numerous piping connections, saving both time and
money with less opportunity for error. With a variety of available piping options, SelectPro makes
it easy to configure pipe packages accurately. All pipe packages are shipped as a complete unit
providing one single point ordering for fast delivery and installation. All piping packages are 100%
tested and backed with a 5-year warranty on all CCV, QCV, and PIQCV packages.

Download SelectPro at
www.belimo.us
18
VALVE ASSEMBLY ACCESSORIES

Added Protection
• Weather shields are designed for additional
valve protection when mounted outdoors.
• Auxiliary switches to indicate when the
desired position of a valve is reached or to
interface controls for a particular control
sequence.
• Feedback potentiometers to provide a
resistive signal.

Michael Jackson, District Sales Manager


Valve Accessories

GK/ AF/ List


WEATHER SHIELDS VALVES LR NR AR GR AKR LF NF LM NM AM GM
GKR AFR Price
Energy
ZS-EPIV-EV-20-NF
Valves

For valve sizes ½” [DN15] to ¾” $593
VALVE ACCESSORIES

[DN20] (cover only)


ePIV •

ZS-EPIV-EV-50-SCNF
Energy
For valve sizes 1” [DN25] to 2”
Valves
• • • •
[DN50] on non-fail-safe actuator
series (cover only) $593
For valve sizes ½” [DN15] to 2”
[DN50] on electronic fail-safe ePIV • • • •
actuator series (cover only)

ZS-EPIV-EV-80 Energy
For ANSI 125, valve sizes 2½” Valves
• •
[DN65] and 3” [DN80] (cover only). $1,302
For assemblies with electromagnetic
ePIV • •
flow sensor only

ZS-EPIV-EV-150 Energy
For ANSI 125, valve sizes 4” Valves
• •
[DN100], 5” [DN125], and 6” $1,302
[DN150] (cover only). For assemblies
ePIV • •
with electromagnetic flow sensor only

ZS-EPIV-EV-80U Energy
For ANSI 125, valve sizes 2½” Valves
• •
[DN65] and 3” [DN80] (cover only). $1,302
For assemblies with ultrasonic flow
ePIV • •
sensor only

ZS-EPIV-EV-150U Energy
For ANSI 125, valve sizes 4” Valves
• •
[DN100], 5” [DN125], and 6” $1,302
[DN150] (cover only). For assemblies
ePIV • •
with ultrasonic flow sensor only

ZS-CCV-90* PICCV •
$258
Kit for LF actuator series CCV •

ZS-CCV-100* PICCV • •
$258
Kit for LR/AR actuator series CCV • •

U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


PICCV •
ZS-CCV-110*
$258
Kit for AFR actuator series CCV •

ZS-SPBV-10

All prices are in US Dollars (USD)


For NM, AM,GM, NF, AF, and GK • • • • • • $333
actuator series

ZS-SPBV-20
For dual mounted GM, AF, and GK • • • $333
actuator series
Ball Valves
ZS-BVVS-0002
For LM actuator series on VS/VSS • $329
models

ZS-BVVS-0003
For LF actuator series on VS/VSS • $329
models

*Designed for NEMA 4 specifications.


NOTE: Weather shields are not available for B6 LGCCV, HTCCV, TFR, TR, ARQ, and KR actuators at this time. Please call 800-543-9038 for assistance.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

18-2
Valve Accessories

2* GR/ 2* 2* LV/ EV/ LVK/ List


WEATHER SHIELDS VALVES GM LF NF AF GK AVK
GM GKR AF GK SV RV SVK Price
ZS-SPGV-60
For LF actuators on NPT series
• $441

VALVE ACCESSORIES
ZS-SPGV-10
For dual AF series actuators on flanged • $464
globe valves

ZS-SPGV-20
For single NF, AF actuator series
• • $464

Globe
ZS-SPGV-40
For GM, GK series on flanged globe valves Valves • • $464

ZS-SPGV-50
For dual GM, GK series on flanged globe valves
• • $464

ZS-GV-001
For LV, SV actuators on NPT series
• • $563

ZS-GV-002
For EV, RV, AVK actuator on flanged series
• • $596

ZS-BFV-20**
For GM, GK actuators on F6, F7, HD, • • $340
HDU, SHP, and VIC series

ZS-BFV-30**
For AF actuators on F6, F7, HD, HDU SHP, • $340
and VIC series

ZS-BFV-60**
For dual GM, GK actuators on
butterfly valves F6, HD, HDU (4” - 6”), SHP,
• • $604
and VIC series

ZS-BFV-70**
For dual AF series on butterfly valves F6, • $604
HD, HDU (2½” - 3”), SHP and VIC series Butterfly
Valves
ZS-BFV-80**
For dual AF series on butterfly valves F6, • $604
HD, HDU (4” - 5”), SHP and VIC series

ZS-BFV-90**
For dual AF, single/dual GM, GK on F7 series • • • • • $604
U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

(2”-4”). No holes unless factory mounted

ZS-BFV-100**
Dual GM/GK series for F7, HD, HDU, SHP • • $604
(4-6”). Two required
All prices are in US Dollars (USD)

ZS-BFV-110
GR, GKR series for F6, HD, HDU (4”-6”)
• $604

**Cannot be used with direct mount actuators.

EPIV SENSORS VALVES LR NR AR GR AK GK List Price


M2415-EP
½” ultrasonic flow sensor
• • $678
M2420-EP
¾” ultrasonic flow sensor
• • $685
M2425-EP
1” ultrasonic flow sensor
• • $899
M2432-EP
1¼” ultrasonic flow sensor
• • $1,382
ePIV
M2440-EP
1½” ultrasonic flow sensor
• • $1,483
M2450-EP
2” ultrasonic flow sensor, 76.1 GPM
• • $1,707
M2450-EP-100
2” ultrasonic flow sensor, 80 to 100 GPM
• • $1,707
EPIVFS-60
2½”-6” ANSI 125 electromagnetic flow sensor
• • • • $1,814

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

18-3
Valve Accessories

List
ENERGY VALVE ACCESSORIES VALVES LR NR AR GR AKR GKR
Price
EV050S-055
½” Energy unit includes flow sensor, control valve, 2 temperature • • $1,175
sensors and 2 fittings for temperature sensors
VALVE ACCESSORIES

EV075S-103
¾” Energy unit includes flow sensor, control valve, 2 temperature • • $1,264
sensors and 2 fittings for temperature sensors
EV100S-182
1” Energy unit includes flow sensor, control valve, 2 temperature • • $1,553
sensors and 2 fittings for temperature sensors
EV125S-285
1¼” Energy unit includes flow sensor, control valve, 2 temperature • • $1,609
sensors and 2 fittings for temperature sensors
EV150S-396
1½” Energy unit includes flow sensor, control valve, 2 temperature • • $1,884
sensors and 2 fittings for temperature sensors
EV200S-761
2” Energy unit includes 76.1 GPM flow sensor, control valve, 2 • • $2,071
temperature sensors, and 2 fittings for temperature sensors
EV200S-1000
2” Energy unit includes 80 to 100 GPM flow sensor, control valve, • • $2,167
2 temperature sensors, and 2 fittings for temperature sensors
M2415-EV
½” Energy Valve ultrasonic flow sensor
• • $1,095

M2420-EV
¾” Energy Valve ultrasonic flow sensor
• • $1,136

M2425-EV
1” Energy Valve ultrasonic flow sensor
• • $1,209

M2432-EV
1¼” Energy Valve ultrasonic flow sensor
• • $1,613

M2440-EV
1½” Energy Valve ultrasonic flow sensor
• • $1,725

M2450-EV
2” Energy Valve ultrasonic flow sensor, up to 76.1 GPM
• • $2,048
Energy Valves
M2450-EV-100
2” Energy Valve flow sensor, 30 to 100 GPM
• • $2,048

U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


EV FS-60
2½” - 6” ANSI 125 Energy Valve electromagnetic flow sensor • • • • $2,131
includes 2 temperature sensors
M24250-EV
2½” ANSI 125 Energy Valve flow sensor includes 2 temperature • • $3,680
sensors. Replacement for ANSI 125 ultrasonic sensor

All prices are in US Dollars (USD)


M24300-EV
3” ANSI 125 Energy Valve flow sensor includes 2 temperature • • $3,761
sensors. Replacement for ANSI 125 ultrasonic sensor
M24400-EV
4” ANSI 125 Energy Valve flow sensor includes 2 temperature • • $3,860
sensors. Replacement for ANSI 125 ultrasonic sensor
M24500-EV
5” ANSI 125 Energy Valve flow sensor includes 2 temperature • • $3,982
sensors. Replacement for ANSI 125 ultrasonic sensor
M24600-EV
6” ANSI 125 Energy Valve flow sensor includes 2 temperature • • $4,451
sensors. Replacement for ANSI 125 ultrasonic sensor
ZF15-50
Temperature sensor, threaded pipe body ½”
• • $125

ZF15-75
Temperature sensor fitting, threaded pipe body ¾”
• • $142

ZF15-100
Temperature sensor fitting, threaded pipe body 1”
• • $145

ZF15-125
Temperature sensor fitting, threaded pipe body 1¼”
• • $165

ZF15-150
Temperature sensor fitting, threaded pipe body 1½”
• • $221

ZF15-200
Temperature sensor fitting, threaded pipe body 2”
• • $329

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

18-4
Valve Accessories

LM/ NM/ GR/ List


BATTERY BACKUP VALVES AM GM AR EV RV PR SY
LR NR DR Price
Ball Valves • • • •
NSV24 US

VALVE ACCESSORIES
Battery backup module
Globe Valves • • $940

Butterfly Valves • • •
Ball Valves • • • •
NSV-BAT
12VDC 1.2 AH battery Globe Valves • • $143
(2 required)
Butterfly Valves • • •
EXT-NSV-B03-120*
Battery backup system for SY4 - SY6 • $7,786
120 VAC, on/off actuators
EXT-NSV-B04-120*
Battery backup system for SY4 - SY6 • $8,933
120 VAC, MFT actuators
EXT-NSV-B05-120*
Battery backup system for SY7 - SY12 • $9,015
120 VAC, on/off actuators
Butterfly Valves
EXT-NSV-B06-120*
Battery backup system for SY7 - SY12 • $9,190
120 VAC, MFT actuators
EXT-NSV-B13-24*
Battery backup system for SY4 - SY5 • $9,636
24 VAC, on/off actuators
EXT-NSV-B14-24*
Battery backup system for SY4 - SY5 • $9,446
24 VAC, MFT actuators
NOTE: Each NSV-24 US requires 2 NSV-BAT.
*All EXT part numbers are not returnable.

List
COVERS
Price
U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

ZS-T Available for all -T Model Actuators


$27
Terminal cover for NEMA 2, -T models (except TR)

VALVE TYPE
All prices are in US Dollars (USD)

PR/PKR TEMPERATURE SENSORS BUTTERFLY List Price

01ST-5L3
Contact Temperature Sensor, NTC10k2, cable 6.5 ft. [2 m]
• $30

01ST-5B3
Contact Temperature Sensor, PT1000, cable 6.5 ft. [2 m]
• $40

01HT-5L
Contact Temperature Sensor, NTC10k2
• $44

01HT-5B
Contact Temperature Sensor, PT1000
• $56

01DT-5LN
Immersion Temperature Sensor, NTC10k2, probe length 6” [150 mm]
• $32

01DT-5LP
Immersion Temperature Sensor, NTC10k2, probe length 8” [200 mm]
• $32

01DT-5BN
Immersion Temperature Sensor, PT1000, probe length 6” [150 mm]
• $49

01DT-5BP
Immersion Temperature Sensor, PT1000, probe length 8” [200 mm]
• $49

A-22P-A09
Thermowell (2 part) stainless steel, 6” [150 mm], ½” NPT
• $35

A-22P-A11
Thermowell (2 part) stainless steel, 8” [200 mm], ½” NPT
• $44

Additional sensor options are located in Section 19.


800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

18-5
Valve Accessories

List
REPLACEMENT TEMPERATURE SENSORS VALVES LR NR AR GR AKR GKR EV AVK
Price
EV-RT-15
Remote temperature sensor 4.9 ft.
• • • • • • $635
VALVE ACCESSORIES

[1.5 m] for valve sizes 2½” to 6”


[DN65-DN150]
EV-RT-30
Remote temperature sensor 9.8 ft.
[3 m] for valve sizes 2½” to 6”
• • • • • • $635
[DN65-DN150]
EV-RT-50
Remote temperature sensor 16.4 ft.
[5 m] for valve sizes 2½” to 6”
• • • • • • $635
[DN65-DN150]
Energy Valves
EV-RT-100
Remote temperature sensor 32.8 ft.
[10 m] for valve sizes 2½” to 6”
• • • • • • $635
[DN65-DN150]
ZM-T15
Remote temperature sensor 4.9 ft.
[1.5 meters] for valve sizes ½” to 2”
• • • • $516
[DN15-DN50]
ZM-T30
Remote temperature sensor 9.8 ft.
[3 m] for valve sizes ½” to 2”
• • • • $516
[DN15-DN50]

List
ZTH REPLACEMENT CABLES VALVES AM GM AR GR DR GK DK SY
Price
ZK1-GEN Ball Valves • •
Cable for use with ZTH US to
connect to new generation non $123
fail-safe and electronic fail-
safe actuators via diagnostic/ Butterfly Valves • • • • • • •
programming socket

ZK2-GEN
Cable for use with ZTH US to

U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


Available for all MFT Actuators Only $57
connect to actuators not equipped
with diagnostic/programming socket

Ball Valves •
ZK6-GEN

All prices are in US Dollars (USD)


Cable for use with ZTH US to $59
connect to SY actuator via RJII port Butterfly Valves •

List
PROGRAMMING TOOLS
Price
Belimo Assistant (NFC) App
Allows fast programming, commissioning, and
Available on NFC Labeled Actuators Only No Charge
troubleshooting even when the actuator is not powered.
Available through Google Play and Apple App Store

MFT-P
Belimo MFT configuration software (V3.X), includes PC-Tool
software (interface cables [ZTH US] not included). Available for all MFT Actuators Only $191
Physical copy of software. Free download also available at
www.belimo.us under “Document Downloads”

ZTH US
Handheld interface module that allows field programming. Available for all MFT Actuators Only $808
Includes ZK1-GEN, ZK2-GEN, and ZK6-GEN cables

ZIP-BT-NFC
Bluetooth® to NFC converter for temporary wireless operation Available for NFC Labeled Actuators Only $273
of Belimo devices with NFC capabilities

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

18-6
Valve Accessories

List
AUXILIARY SWITCHES & POTENTIOMETERS VALVES LR/LM NR/NM AR/AM GR/GM AK GK/GKR DR/DK
Price
S1A
Auxiliary switch 1x SPDT, 3A • • • • • • • $101

VALVE ACCESSORIES
(0.5A inductive) @ 250 VAC
S2A
Auxiliary switch 2x SPDT, 3A • • • • • • • $151
(0.5A inductive) @ 250 VAC
P140A GR
Feedback potentiometer 140 Ω
• • • • • • • $165

P500A GR
Feedback potentiometer 500 Ω
• • • • • • • $165
Available for
P500A GR All Valves
Feedback potentiometer 500 Ω
• • • • • • • $165

P1000A GR
Feedback potentiometer 1000 Ω
• • • • • • • $165

P2800A GR
Feedback potentiometer 2800 Ω
• • • • • • • $165

P5000A GR
Feedback potentiometer 5000 Ω
• • • • • • • $165

P10000A GR
Feedback potentiometer 10000 Ω
• • • • • • • $165

List
VALVES LV/SV EV RV LVK/SVK AVK SY
Price
S2A-GV Energy Valves • •
Auxiliary switch 2x SPDT, 3A
(0.5A inductive) @ 250 VAC for LV,
ePIV • • $150
SV, EV, and AVK series actuators. Globe Valves • • • • •

SY-1000-FB01 Ball Valves •


Feedback potentiometer 1000 Ω, 2 Butterfly $295
position, factory installed option only Valves

SY-1000-FB02 Ball Valves •


Feedback potentiometer 1000 Ω,
Butterfly $295
modulating (models SYx…-MFT), •
factory installed option only Valves
U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

List
EXTENSION BRACKET* VALVES LR AR LF AF AFR
Price
CCV-EXT-KIT
Neck extension kit for M5 screw for CCV bodies up to 2011
CCV • • • • $231

PICCV • • • •
All prices are in US Dollars (USD)

CCV-EXT-M4
Linkage extension kit for CCV and PICCV bodies 2012 to $231
present CCV • • • •

*CCV-EXT-KIT and CCV-EXT-M4 are options for all CCV models except B6 flanged valves. Not compatible with N4 actuators.

List
ELECTRIC DISCONNECT VALVES SY
Price
HOA-120V Ball Valves •
$548
Local electric disconnect for SY4-SY12 110/230V - 2 position Butterfly Valves •

HOA-120VMFT Ball Valves •


$548
Local electric disconnect for SY4-SY12 110/230V - modulating Butterfly Valves •

HOA-24V Ball Valves •


$548
Local electric disconnect for SY4-SY12 24V - 2 position Butterfly Valves •

HOA-24VMFT Ball Valves •


$548
Local electric disconnect for SY4-SY12 24V - modulating Butterfly Valves •
List
HAND CRANK PR PKR
Price

ZG-HND PR
Replacement hand crank for PR and PKR actuators
• • $42

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

18-7
Valve Accessories

VALVE TYPE
ZONETIGHT VALVE ACCESSORIES VALVES Z2 (2-WAY) Z3 (3-WAY) List Price
VALVE ACCESSORIES

PIQCV •
ZCQB-FL
$59
Flow setter
QCV •

ZCQ-E
PIQCV •
QCV or PIQCV valve stem extension.
$26
Designed for chilled water service up to 104°F
[40°C] media temperature
QCV • •

FLOW ORIFICE

FO15010 PIQCV •
$86
½” Flow orifice for 1.0 GPM QCV •

FO15025 PIQCV •
$86
½” Flow orifice for 2.5 GPM QCV •

FO15055 PIQCV •
$86
½” Flow orifice for 5.5 GPM QCV •
FO20100
¾” Flow orifice for 10.0 GPM
QCV • $92

ARCHITECTURAL COVER

PIQCV •
ZCQB-W
$22
Housing cover for CQ actuators (white)
QCV • •

U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


VALVE TYPE
MOUNTING BRACKET 6-WAY CCV List Price

All prices are in US Dollars (USD)


ZR-004
Mounting bracket for 6-way CCV. • $33
Includes screw kit M4.

VALVE TYPE
PR/PKR RETROFIT LINKAGE BUTTERFLY List Price

IND-PR01
Valve linkage for 4” - 6” HDU/HD series 2-way • $126
with indicator
IND-PR02
Valve linkage for 4” - 6” HDU/HD series 2-way • $63
without indicator
IND-PR03
Valve linkage for 8” - 12” L series 2-way • $126
with indicator
IND-PR04
Valve linkage for 8” - 12” L series 2-way • $63
without indicator

Butterfly Manual Handle and Gear Operator options located on page 16-31.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

18-8
19

SENSORS
SENSORS

Experience Installation Ease


• Innovative technology to work seamlessly
with all major control systems ensuring
top performance.
• Reliable and accurate readings providing
energy and cost-efficient control backed
with a 5-year warranty.
• Universal compact modular design
features a screw-less snap cover with a
detachable mounting plate and NEMA 4X/
IP65 rating for quick installation and
commissioning.

David Alliband, Manager, PM Sensors


Duct / Immersion Sensor Nomenclature
Temperature

01 D T - 5 A H
Power Application Medium Region Signal Type Length [mm]
01 = Passive C = Cable Flange T = Temperature 5 = Americas A = PT100 H = 2” [50]
D = Duct / Immersion B = PT1000 L = 4” [100]
E = Ni1000 N = 6” [150]
L = NTC10k2 P = 8” [200]
M = NTC10k3 R = 12” [300]
Q = NTC20k T = 18” [450]

Duct and immersion temperature sensors for duct and pipe


applications provides air or water temperature (with A-22P-A series
Thermowell) readings to air handling equipment, unitary HVAC
equipment, and central plants. Duct flange mount sensors with
adjustable mounting flange are ideal for HVAC equipment that do not
require electrical conduit for example AHU, FCU and VAV applications.

PT.. = ±0.5°F @ 32°F [±0.3°C @ 0°C]


Accuracy Ni.. = ±0.7°F @ 32°F [±0.4°C @ 0°C]
NTC.. = ±0.3°F @ 77°F [±0.2°C @ 25°C]
01DT 01CT
cable gland with strain relief Ø6 to 8 mm,
Cable Entry
½” conduit adapter included
Includes Duct Mounting Kit
Ambient Temperature Includes Adjustable
01DT -30°F to 120°F [-35°C to 50°C] Mounting Flange
SENSORS

01CT -30°F to 210°F [-35°C to 100°C] ½” Thermowell adaptor available for retrofit
Operating Temperature applications. See accessories section on page
19-23.
01DT NTC..= -60°F to 300°F [-50°C to 150°C]
PT., Ni.. = -60°F to 320°F [-50°C to 160°C]
01CT -30°F to 210°F [-35°C to 100°C]
Degree of Protection
01DT NEMA 4X, IP65
01CT NEMA 4X, IP67
cULus acc. to UL60730-1A/-2-9, CAN/CSA
E60730-1:02/-2-9, CE acc. to 2014/30/EU,
Agency Listing
RoHS acc. to 2011/65/EU, UL Enclosure
Type 4X
01DT Optional Accessory
A-22D-A03 Adjustable Duct
Mounting Flange
Duct / Immersion Sensor Product Range
Temperature

Measuring Values
List Price

Probe Length [mm]

Cable Length [m]


Output Signal
Temperature

Temperature
01DT-5AH PT100 2" [50] $49
01DT-5AL PT100 4" [100] $49

SENSORS
01DT-5AN PT100 6" [150] $49
01DT-5AP PT100 8" [200] $49
01DT-5AR PT100 12" [300] $49
01DT-5AT PT100 18" [450] $56
01DT-5BH PT1000 2" [50] $49
01DT-5BL PT1000 4" [100] $49
01DT-5BN PT1000 6" [150] $49
01DT-5BP PT1000 8" [200] $49
01DT-5BR PT1000 12" [300] $49
01DT-5BT PT1000 18" [450] $56
01DT-5EH Ni1000 2" [50] $39
01DT-5EL Ni1000 4" [100] $39
01DT-5EN Ni1000 6" [150] $39
01DT-5EP Ni1000 8" [200] $39
01DT-5ER Ni1000 12" [300] $39
01DT-5ET Ni1000 18" [450] $56
Passive
01DT-5LH NTC10k2 2" [50] $32
01DT-5LL NTC10k2 4" [100] $32
01DT-5LN NTC10k2 6" [150] $32
01DT-5LP NTC10k2 8" [200] $32
01DT-5LR NTC10k2 12" [300] $32
U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

01DT-5LT NTC10k2 18" [450] $49


01DT-5MH NTC10K3 2" [50] $32
01DT-5ML NTC10K3 4" [100] $32
01DT-5MN NTC10K3 6" [150] $32
All prices are in US Dollars (USD)

01DT-5MP NTC10K3 8" [200] $32


01DT-5MR NTC10K3 12" [300] $32
01DT-5MT NTC10K3 18" [450] $49
01DT-5QH NTC20K 2" [50] $32
01DT-5QL NTC20K 4" [100] $32
01DT-5QN NTC20K 6" [150] $32
01DT-5QP NTC20K 8" [200] $32
01DT-5QR NTC20K 12" [300] $32
01DT-5QT NTC20K 18" [450] $49

Cable Flange
01CT-5BL PT1000 4" [100] 6.5 ft. [2] $38
01CT-5BP PT1000 8" [200] 6.5 ft. [2] $38
01CT-5LL NTC10k2 4" [100] 6.5 ft. [2] $27
01CT-5LP NTC10k2 8" [200] 6.5 ft. [2] $27
Passive
01CT-5ML NTC10K3 4" [100] 6.5 ft. [2] $27
01CT-5MP NTC10K3 8" [200] 6.5 ft. [2] $27
01CT-5QL NTC20K 4" [100] 6.5 ft. [2] $27
01CT-5QP NTC20K 8" [200] 6.5 ft. [2] $27
Please note: For temperature and humidity sensors, the °F and °C are not direct conversions. °F is the standard range for the United States, and °C is the standard range
for Canada and Latin America.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN


19-1
Duct / Immersion Sensor Nomenclature
Temperature

22 D T - 5 2 H
Power Application Medium Region Signal Type Length [mm]
22 = Active D = Duct / Immersion T = Temperature 5 = Americas 2 = VDC (Volt) Multi Range H = 2” [50]
4 = 4-20 mA Multi Range L = 4” [100]
N = 6” [150]
P = 8” [200]
R = 12” [300]
Duct and immersion temperature sensor for duct and pipe
T = 18” [450]
applications provides air or water temperature readings to air
handling equipment, unitary HVAC equipment, and central plants.

Accuracy ±1% of upper selected measuring range


SENSORS

DC 15...24 V (± 10%), AC 24 V (± 10%)


Power Supply
DC 15...24 V (± 10%) (4-20 mA)
cable gland with strain relief Ø6 to 8 mm,
Cable Entry
½” conduit adapter included
Ambient Temperature -30°F to 120°F [-35°C to 50°C] 22DT Optional Accessory
Operating Temperature -60°F to 320°F [-50°C to 160°C] Includes Duct Mounting Kit A-22D-A03 Adjustable Duct
Mounting Flange
Degree of Protection NEMA 4X, IP65 22DT
cULus acc. to UL60730-1A/-2-9, CAN/CSA
E60730-1:02/-2-9, CE acc. to 2014/30/EU,
Agency Listing ½” Thermowell adaptor available for retrofit
RoHS acc. to 2011/65/EU, UL Enclosure
applications. See accessories section on page
Type 4X
19-23.

Duct Averaging Sensor Nomenclature


Temperature

01 M T - 5 B 4
Power Application Medium Region Signal Type Length

U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


01 = Passive M = Averaging (Duct) T = Temperature 5 = Americas 2 = VDC (Volt) Multi Range 4 = 10 ft. [3 m]
22 = Active 4 = 4-20 mA Multi Range 5 = 20 ft. [6 m]
B = PT1000
E = Ni1000

All prices are in US Dollars (USD)


Duct averaging sensors with 10 or 20 foot [3 or 6 meter] probes are for
applications where stratified layers of hot and cold air can occur when L = NTC10k2
outside air and return air are mixed. PT1000 version is true averaging and M = NTC10k3
one continuous RTD across entire length of the probe to combat against
air stratification problems. Q = NTC20k
Accuracy
22MT ±1% of upper selected measuring range
PT.. = ±0.5°F @ 32°F [±0.3°C @ 0°C]
01MT Ni.. = ±0.7°F @ 32°F [±0.4°C @ 0°C]
NTC.. = ±0.3°F @ 77°F [±0.2°C @ 25°C]
cable gland with strain relief Ø6 to 8 mm,
Cable Entry
½” conduit adapter included
Ambient Temperature
Passive -30°F to 120°F [-35°C to 50°C]
Active -30°F to 120°F [-35°C to 50°C]
Operating Temperature
Passive Includes Mounting
PT, Ni -30°F to 160°F [-35°C to 70°C] Brackets
NTC 32°F to 120°F [0°C to 50°C]
Active -30°F to 160°F [-35°C to 70°C]
Degree of Protection NEMA 4X, IP65 22MT and 01MT
Agency Listing cULus acc. to UL60730-1A/-2-9, CAN/CSA
E60730-1:02/-2-9, CE acc. to 2014/30/EU,
RoHS acc. to 2011/65/EU, UL Enclosure
Type 4X

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

19-2
Duct / Immersion and Duct Averaging Sensor Product Range
Temperature

Measuring Values Measuring Ranges


Additional
List Price
Temperature Features

-30°F to +130°F [-50°C to +50°C]

0°F to 250°F [-10°C to +120°C]


0°F to 100°F [-15°C to +35°C]

40°F to 90°F [-20°C to +80°C]


30°F to 480°F [0°C to 250°C]

40°F to 240°F [0°C to 100°C]


0°F to 150°F [0°C to 160°C]

40°F to 140°F [0°C to 50°C]

Probe Length [mm]


Output Signals

Multirange
(default)

Duct / Immersion
Temperature

SENSORS
22DT-52H DC 0-5V (DC 0-10V) 8         2" [50] $161
22DT-52L DC 0-5V (DC 0-10V) 8         4" [100] $161
22DT-52N DC 0-5V (DC 0-10V) 8         6" [150] $161
22DT-52P DC 0-5V (DC 0-10V) 8         8" [200] $161
22DT-52R DC 0-5V (DC 0-10V) 8         12" [300] $161
22DT-52T DC 0-5V (DC 0-10V) 8         18" [450] $161
Active
22DT-54H 4-20 mA 8         2" [50] $161
22DT-54L 4-20 mA 8         4" [100] $161
22DT-54N 4-20 mA 8         6" [150] $161
22DT-54P 4-20 mA 8         8" [200] $161
22DT-54R 4-20 mA 8         12" [300] $161
22DT-54T 4-20 mA 8         18" [450] $161

Measuring Values
Additional
List Price
Temperature Features
-30°F to +130°F [-50°C to +50°C]
U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

0°F to 250°F [-10°C to +120°C]


0°F to 100°F [-15°C to +35°C]

40°F to 90°F [-20°C to +80°C]


30°F to 480°F [0°C to 250°C]

40°F to 240°F [0°C to 100°C]


0°F to 150°F [0°C to 160°C]

40°F to 140°F [0°C to 50°C]

Probe Length [m]


Output Signals
All prices are in US Dollars (USD)

Multirange
(default)

Duct Averaging
Temperature
01MT-5B4 PT1000 10 ft [3] $269
01MT-5B5 PT1000 20 ft [6] $308
01MT-5E4 Ni1000 10 ft [3] $250
01MT-5E5 Ni1000 20 ft [6] $308
01MT-5L4 NTC10k2 10 ft [3] $192
Passive
01MT-5L5 NTC10k2 20 ft [6] $238
01MT-5M4 NTC10K3 10 ft [3] $192
01MT-5M5 NTC10K3 20 ft [6] $238
01MT-5Q4 NTC20K 10 ft [3] $192
01MT-5Q5 NTC20K 20 ft [6] $238
22MT-524 DC 0-5V (DC 0-10V) 8         10 ft [3] $405
22MT-525 DC 0-5V (DC 0-10V) 8         20 ft [6] $444
Active
22MT-544 4-20 mA 8         10 ft [3] $405
22MT-545 4-20 mA 8         20 ft [6] $444

• Factory setting (setting ranges are configurable on the sensor).


Please note: For temperature and humidity sensors, the °F and °C are not direct conversions. °F is the standard range for the United States, and °C is the standard range for Canada
and Latin America.

Active selectable measuring ranges are for application and scaling purposes, please ensure installation is within stated ambient and operating temperature range.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN


19-3
Cable Sensor Nomenclature
Temperature

22 C T - 5 2 H
Power Application Medium Region Signal Type Length [mm]
01 = Passive C = Cable T = Temperature 5 = Americas 2 = VDC (Volt) Multi Range H = 2” [50]
22 = Active 4 = 4-20 mA Multi Range
A = PT100
Cable temperature sensors with two-inch stainless steel probe are B = PT1000
designed to measures air or water temperature for duct and pipe E = Ni1000
applications.
L = NTC10k2
Accuracy
22CT ±1% of upper selected measuring range M = NTC10k3
PT.. = ±0.5°F @ 32°F [±0.3°C @ 0°C] Q = NTC20k
01CT Ni.. = ±0.7°F @ 32°F [±0.4°C @ 0°C]
SENSORS

NTC.. = ±0.3°F @ 77°F [±0.2°C @ 25°C]


Power Supply
DC 15...24 V (± 10%), AC 24 V (± 10%)
22CT
DC 15...24 V (± 10%) (4-20 mA)
Cable Entry
cable gland with strain relief Ø6 to 8 mm,
22CT
½” conduit adapter included
Ambient Temperature
Passive -30°F to 210°F [-35°C to 100°C]
Active -30°F to 120°F [-35°C to 50°C]
Operating Temperature
Passive -30°F to 210°F [-35°C to 100°C]
Active -60°F to 250°F [-50°C to 120°C] 22CT 01CT A-22D-A09
Mounting Plate
Degree of Protection Includes Mounting Plate
22CT NEMA 4X, IP65
01CT NEMA 4X, IP67
Agency Listing cULus acc. to UL60730-1A/-2-9, CAN/CSA
E60730-1:02/-2-9, CE acc. to 2014/30/EU,
RoHS acc. to 2011/65/EU, UL Enclosure
Type 4X

Low Limit Detection Sensor Nomenclature

U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


Temperature

01 D TS - 5 0 4 X

All prices are in US Dollars (USD)


Power Application Medium Region Signal Type Length Details
01 = Passive D = Low Limit Detection TS = Temperature & Switch 5 = Americas 0 = Switch 4 = 10 ft. [3 m] Blank = Auto Reset
5 = 20 ft. [6 m] X = Manual Reset

Duct mounted low-temperature detection sensors with vapor filled


copper capillary tube are used to protect water coils from freezing
within the air handling equipment. Any section of the capillary tube
that is below the setpoint will cause the vapor to condense to a liquid Includes Mounting Clips
and trip the SPDT contact. Reset option is manual or automatic.

Accuracy ±0.9°F [±0.5°C]


cable gland cap nut with strain relief Ø6
Cable Entry
to 8 mm
Ambient Temperature -30°F to 160°F [-35°C to 70°C]
Operating Temperature -30°F to 160°F [-35°C to 70°C] 01DTS
Degree of Protection NEMA 4, IP65

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

19-4
Cable and Low Limit Detection Sensor Product Range
Temperature

Measuring Values Measuring Ranges


Temperature Additional Features List Price

-30°F to 130°F [-50°C to 50°C]

0°F to 250°F [-10°C to 120°C]

30°F to 480°F [0°C to 250°C]

40°F to 240°F [0°C to 100°C]


0°F to 100°F [-15°C to 35°C]

40°F to 90°F [-20°C to 80°C]


0°F to 150°F [0°C to 160°C]

40°F to 140°F [0°C to 50°C]

Probe Length [mm]

Cable Length [m]


Output Signals

Multirange
(default)

Cable
Temperature

SENSORS
22CT-52H DC 0-5V (DC 0-10V) 8         2" [50] 6.5 ft [2] $162
Active
22CT-54H 4-20 mA 8         2" [50] 6.5 ft [2] $162
01CT-5AH PT100 2" [50] 6.5 ft [2] $38
01CT-5BH PT1000 2" [50] 6.5 ft [2] $38
01CT-5EH Ni1000 2" [50] 6.5 ft [2] $38
Passive
01CT-5LH NTC10k2 2" [50] 6.5 ft [2] $22
01CT-5MH NTC10K3 2" [50] 6.5 ft [2] $22
01CT-5QH NTC20K 2" [50] 6.5 ft [2] $22
U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

Measuring Values
Additional
Output Setpoint List Price
All prices are in US Dollars (USD)

Reset Features
Signal Range
14°F to 54°F [-10°C to 12°C]

Probe Length [m]

Low Limit Detection


Manual

Temperature (Frost
SPDT

Auto

Protection)
01DTS-504    10 ft [3] $250
01DTS-504X    10 ft [3] $268
Switch
01DTS-505    20 ft [6] $272
01DTS-505X    20 ft [6] $300

• Factory setting (setting ranges are configurable on the sensor).


Please note: For temperature and humidity sensors, the °F and °C are not direct conversions. °F is the standard range for the United States, and °C is the standard
range for Canada and Latin America.

Active selectable measuring ranges are for application and scaling purposes, please ensure installation is within stated ambient and operating temperature range.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN


19-5
Duct Sensor Nomenclature
Temperature / Humidity

22 D TH - 5 1 M B
Power Application Medium Region Signal Type Length [mm] Details
22 = Active D = Duct TH = Temperature & Humidity 5 = Americas 1 = VDC (Volt) M = 5” [140] B = PT1000
3 = 4-20 mA E = Ni1000
5 = Modbus L = NTC10k2
6 = BACnet M = NTC10k3
Q = NTC20k

Duct mounted combination temperature and humidity sensors are


factory set to relative humidity to manage occupant comfort settings.
SENSORS

Field selectable with absolute humidity output which determines


the moisture content, dew point output manages space moisture,
enthalpy output defines the amount of outside air for free cooling by
the air handling equipment with integrated economizer sequence.
Available with active or passive temperature outputs.

Accuracy
Active = ±0.9°F @ 70°F [±0.5°C @ 21°C]
PT.. = ±0.5°F @ 32°F [±0.3°C @ 0°C]
Temperature
Ni.. = ±0.7°F @ 32°F [±0.4°C @ 0°C]
NTC.. = ±0.3°F @ 77°F [±0.2°C @ 25°C]
±2% between 10 to 90% RH @ 70°F
Humidity
[21°C]
DC 15...24 V (± 10%), AC 24 V (± 10%)
Power Supply
DC 15...24 V (± 10%) (4-20 mA) 22DTH Includes Adjustable
cable gland with strain relief Ø6 to 8 mm, Mounting Flange
Cable Entry
½” conduit adapter included
Ambient Temperature -30°F to 120°F [-35°C to 50°C]
Operating Temperature -40°F to 175°F [-40°C to 80°C]
Degree of Protection NEMA 4X, IP65
Agency Listing cULus acc. to UL60730-1A/-2-9/-2-13,
CAN/CSA E60730-1:02/-2-9, CE acc. to
2014/30/EU, RoHS acc. to 2011/65/EU,
UL Enclosure Type 4X

U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


All prices are in US Dollars (USD)

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

19-6
Duct Sensor Product Range
Temperature / Humidity

Measuring Values Measuring Ranges


Relative Absolute Additional Features List Price
Temperature Dewpoint Enthalpy
Humidity Humidity

40°F to 140°F [0°C to 50°C] (default)


0 to 50 g/m³ (default) 0 to 80 g/m³
-40°F to 160°F [-40°C to 60°C]

0 to 100% RH non-condensing

0°F to 200°F [-20°C to +80°C]


0°F to 100°F [-15°C to 35°C]

0°F to 200°F [-20°C to 80°C]


40°F to 140°F [0°C to 50°C]

Probe Length [mm]


Communication
Output Signal

Output Signal

0 to 85 kJ/kg
Temperature

Temperature

Multirange
Humidity
(default)

(default)
Humidity /

SENSORS
Temperature
DC 0-5V DC 0-5V 5.5"
22DTH-51M 4         $315
(DC 0-10V) (DC 0-10V) [140]
Active
5.5”
22DTH-53M 4-20 mA 4-20 mA 4         $315
[140]
DC 0-5V 5.5”
22DTH-51MB PT1000     $315
(DC 0-10V) [140]
DC 0-5V 5.5”
22DTH-51ME Ni1000     $315
(DC 0-10V) [140]
DC 0-5V 5.5”
22DTH-51ML Passive NTC10k2     $315
(DC 0-10V) [140]
DC 0-5V 5.5”
22DTH-51MM NTC10k3     $315
(DC 0-10V) [140]
DC 0-5V 5.5”
22DTH-51MQ NTC20k     $315
(DC 0-10V) [140]
5.5”
22DTH-53MB PT1000 4-20 mA     $315
[140]
5.5”
22DTH-53ME Ni1000 4-20 mA     $315
[140]
5.5”
22DTH-53ML Passive NTC10k2 4-20 mA     $315
[140]
U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

5.5”
22DTH-53MM NTC10k3 4-20 mA     $315
[140]
5.5”
22DTH-53MQ NTC20k 4-20 mA     $315
[140]
All prices are in US Dollars (USD)

DC 0-5V DC 0-5V 5.5”


22DTH-55M     Modbus RTU $385
(DC 0-10V) (DC 0-10V) [140]
Active
DC 0-5V DC 0-5V 5.5”
22DTH-56M     BACnet MS/TP $385
(DC 0-10V) (DC 0-10V) [140]

• Factory setting (setting ranges are configurable on the sensor).


Please note: For temperature and humidity sensors, the °F and °C are not direct conversions. °F is the standard range for the United States, and °C is the standard range for Canada and Latin America.

Active selectable measuring ranges are for application and scaling purposes, please ensure installation is within stated ambient and operating temperature range.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN


19-7
Duct Sensor Nomenclature
Air Quality

22 D TM - 5 1 0 6
Power Application Medium Region Signal Type Length Details
22 = Active D = Duct C = CO2 5 = Americas 1 = VDC (Volt) 0 = N/A 6 = LCD Display
CK = CO2, VOC, Temperature, CO2 / VOC Mix 1 = Canada/LA 3 = 4-20 mA
CM = CO2, VOC, Temperature 6 = BACnet
CV = CO2, VOC
TC = Temperature, CO2
TM = Temperature, Humidity, CO2
SENSORS

Combined duct mounted air quality sensors for detection of CO2,


VOC, temperature, and humidity. The dual channel CO2 sensor
monitors building occupancy levels and is used to control the
amount of outside air supplied by the air handling equipment to
ensure air quality and maximize energy savings over the life-cycle
of the building.

Accuracy
Temperature ±0.9 °F @ 70 °F [±0.5 °C @ 21 °C]
±2% between 10 to 90% RH @ 70°F
Humidity
[21°C]
CO2 ±50 ppm and 3% of reading
Power Supply DC 15...24 V (±10%), AC 24 V (±10%)
cable gland with strain relief Ø6 to 8 mm, 22DTM Includes Adjustable
Cable Entry Mounting Flange
½” conduit adapter included
Ambient Temperature 32°F to 120°F [0°C to 50°C]
Operating Temperature 32°F to 120°F [0°C to 50°C]
Degree of Protection NEMA 4X, IP65
Agency Listing cULus acc. to UL60730-1A/-2-9, CAN/CSA
E60730-1:02/-2-9, CE acc. to 2014/30/EU,
RoHS acc. to 2011/65/EU, UL Enclosure
Type 4X

U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


All prices are in US Dollars (USD)

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

19-8
Duct Sensor Product Range
Air Quality

Measuring Values Measuring Ranges


Relative Additional Features List Price
Temperature CO2 VOC
Humidity

0 to 100% RH non-condensing

Probe Length [mm]


Communication
0 to 2000 ppm

0 to 5000 ppm
Output Signals

40°F to 140°F

0°C to 50°C

0 to 100%

Display

SENSORS
CO2
22DC-51 DC 0-10V  7" [180] $540
22DC-53 4-20 mA  7" [180] $540

CO2 / Temperature
22DTC-51 DC 0-5 V, DC 0-10 V   7" [180] $617
22DTC-11* DC 0-5 V, DC 0-10 V   7" [180] $617
22DTC-53 4-20 mA   7" [180] $617
22DTC-13* 4-20 mA   7" [180] $617
22DTC-5105 DC 0-5 V, DC 0-10 V   7" [180] $617
22DTC-1105* DC 0-5 V, DC 0-10 V   7" [180] $617

CO2 / Humidity / Temperature


22DTM-51 DC 0-10 V    7" [180] $811
22DTM-11* DC 0-10 V    7" [180] $811
Active
22DTM-5106 DC 0-10 V    7" [180] LCD $946
22DTM-1106* DC 0-10 V    7" [180] LCD $946
22DTM-56 DC 0-5/10 V    BACnet MS/TP 7" [180] $829

CO2 / VOC
22DCV-51 DC 0-5 V, DC 0-10 V   7" [180] $887
U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

CO2 / VOC / Mix CO2 + VOC /


Temperature
22DCK-51 DC 0-5 V, DC 0-10 V    7" [180] $1,041
22DCK-11* DC 0-5 V, DC 0-10 V    7" [180] $1,041
All prices are in US Dollars (USD)

CO2 / VOC / Temperature


22DCM-51 DC 0-5 V, DC 0-10 V    7" [180] $964
22DCM-11* DC 0-5 V, DC 0-10 V    7" [180] $964

*Temperature range configured for degrees Celsius.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN


19-9
Duct Switch Nomenclature
Pressure

01 A PS - 5 0 1 .1
Power Application Medium Region Signal Type Range Option
01 = Passive A = Air PS = Pressure Switch 5 = Americas 0 = Switch R = 0.08” to 1.2”wc [20-300Pa] .1=Multi-pack
U = 0.2” to 2.0”wc [50-500Pa]
1 = 0.8” to 4.0”wc [200-1000Pa]
4 = 2.0” to 10”wc [500-2500Pa]

Duct mounted pressure switches monitor overpressure, vacuum and


differential pressure of air or other noncombustible, non-aggressive
gases. The differential pressure switches with automatic reset and field
adjustable differential setpoint are used in air handling applications to
SENSORS

monitor air filter cleanliness and fan status.

See data sheet for Accuracy and


Accuracy
Repeatability
cable gland M20 x 1.5 mm with strain
Cable Entry relief Ø6 to 8 mm, ½” conduit adapter
included
Ambient Temperature -5°F to 185°F [-20°C to 85°C]
Operating Temperature -5°F to 185°F [-20°C to 85°C]
01APS Includes 6.5 ft. [2 m] tubing
Degree of Protection NEMA 13, IP54 and two 4” [100 mm]
Agency Listing ETL listed plastic probes

Duct Sensor Nomenclature


Pressure

22 A DP - 5 5 Q A

U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


Power Application Medium Region Signal Type Range Details
22 = Active A = Air DP = Differential Pressure 5 = Americas 5 = Modbus Q = 1”wc [250Pa] Selectable Blank = Standard
8 = 4-20 mA & VDC 4 = 10”wc [2500Pa] Selectable A = Auto Zero

All prices are in US Dollars (USD)


Multi Range
1 = 28”wc [7000Pa] Selectable B = Auto Zero + LCD
L = LCD

Duct mounted pressure sensors monitor overpressure, vacuum and


differential pressure of air or other noncombustible, non-aggressive
gases. The differential pressure sensors with optional LCD, Modbus
communications, true auto-zero or manual calibration are used to
control air handler supply and return fan speed, maintain a differential
pressure between spaces such as hospital isolation rooms or building Includes 6.5 ft. [2 m] tubing and
entrances. two 4” [100 mm] plastic probes
Refer to datasheet for accuracy on all field
Accuracy
selectable pressure ranges
Power Supply DC 15...24 V (± 10%), AC 24 V (± 10%)
cable gland with strain relief Ø6 to 8 mm,
Cable Entry
½” conduit adapter included
Ambient Temperature -15°F to 120°F [-10°C to 50°C]
Operating Temperature -15°F to 120°F [-10°C to 50°C]
Degree of Protection NEMA 4X, IP65 22ADP
A-22D-A10
Agency Listing cULus acc. to UL60730-1A/-2-6, CAN/CSA
Mounting Plate
E60730-1:02, CE acc. to 2014/30/EU, RoHS
acc. to 2011/65/EU, UL Enclosure Type 4X

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

19-10
Duct Switch and Duct Sensor Product Range
Pressure

Measuring Values Measuring Ranges


Units List Price
Pressure

2.00 to 10.00 inch WC [500...2500 Pa]


0.80 to 4.00 inch WC [200...1000 Pa]
0.08 to 1.20 inch WC [20...300 Pa]

0.20 to 2.00 inch WC [50...500 Pa]


Output Signals

package of 45
(default)

Differential Pressure
Switch
01APS-501 SPDT  $68

SENSORS
01APS-501.1 SPDT   $55
01APS-504 SPDT  $68
01APS-504.1 SPDT   $55
Switch
01APS-50R SPDT  $68
01APS-50R.1 SPDT   $55
01APS-50U SPDT  $68
01APS-50U.1 SPDT   $55

Measuring Values Measuring Ranges


Additional Features List Price
Pressure
-0.4 to 0.4 inch WC [-100 to 100 Pa]

-0.6 to 0.6 inch WC [-150 to 150 Pa]


-0.1 to 0.1 inch WC [-25 to 25 Pa]

-0.2 to 0.2 inch WC [-50 to 50 Pa]

0 to 10 inch WC [0 to 2500 Pa]

0 to 12 inch WC [0 to 3000 Pa]

0 to 16 inch WC [0 to 4000 Pa]

0 to 20 inch WC [0 to 5000 Pa]

0 to 28 inch WC [0 to 7000 Pa]


0 to 0.4 inch WC [0 to 100 Pa]

0 to 4 inch WC [0 to 1000 Pa]

0 to 6 inch WC [0 to 1500 Pa]

0 to 8 inch WC [0 to 2000 Pa]


0 to 0.1 inch WC [0 to 25 Pa]

0 to 0.2 inch WC [0 to 50 Pa]

0 to 1 inch WC [0 to 250 Pa]

0 to 2 inch WC [0 to 500 Pa]

Auto Zero - Calibration

Communication
Output Signals

Multirange
(default)

Display
Differential Pressure
Sensor
U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

DC 0-5 V
22ADP-58Q 8         $289
(DC 0-10 V, 4-20 mA)
DC 0-5 V
22ADP-58QA 8          $370
(DC 0-10 V, 4-20 mA)
DC 0-5 V
All prices are in US Dollars (USD)

22ADP-58QB 8          LCD $481


(DC 0-10 V, 4-20 mA)
DC 0-5 V
22ADP-58QL 8         LCD $354
(DC 0-10 V, 4-20 mA)
22ADP-55Q DC 0-5 V (DC 0-10 V) 8         Modbus RTU $354
22ADP-55QA DC 0-5 V (DC 0-10 V) 8          Modbus RTU $461
22ADP-55QB DC 0-5 V (DC 0-10 V) 8          Modbus RTU LCD $538
22ADP-55QL DC 0-5 V (DC 0-10 V) 8         Modbus RTU LCD $461
Active
DC 0-5 V
22ADP-584 8         $289
(DC 0-10 V, 4-20 mA)
DC 0-5 V
22ADP-584L 8         LCD $354
(DC 0-10 V, 4-20 mA)
22ADP-554 DC 0-5 V (DC 0-10 V) 8         Modbus RTU $354
22ADP-554L DC 0-5 V (DC 0-10 V) 8         Modbus RTU LCD $461
22ADP-556 DC 0-5 V (DC 0-10 V) 8         Modbus RTU $354
22ADP-556L DC 0-5 V (DC 0-10 V) 8         Modbus RTU LCD $461
DC 0-5 V
22ADP-586 8         $289
(DC 0-10 V, 4-20 mA)
DC 0-5 V
22ADP-586L 8         LCD $354
(DC 0-10 V, 4-20 mA)

• Factory setting (setting ranges are configurable on the sensor).

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN


19-11
Pipe Sensor Nomenclature
Temperature

22 H T - 5 A 3
Power Application Medium Region Signal Type Length
01 = Passive H = Surface Mount (Housing) T = Temperature 5 = Americas 2 = VDC (Volt) Multi Range 3 = 6.5 ft. [2 m]
22 = Active S = Surface Mount (Cable) 4 = 4-20 mA Multi Range
A = PT100
B = PT1000
E = Ni1000
01HT and 22HT are surface mounted strap-on temperature sensors that
incorporates a spring loaded brass contact to ensure fast response and L = NTC10k2
accurate hydronic temperature readings. 01ST range offers a 2” brass
probe arched surface for fast response and has a plenum rated cable. M = NTC10k3
Both models include adjustable pipe clamp. Q = NTC20k
SENSORS

Accuracy
PT.. = ±0.5°F @ 32°F [±0.3°C @ 0°C]
01ST, 01HT Ni.. = ±0.7°F @ 32°F [±0.4°C @ 0°C]
NTC.. = ±0.3°F @ 77°F [±0.2°C @ 25°C]
22HT ±1% of upper selected measuring range
DC 15...24 V (± 10%), AC 24 V (± 10%)
Power Supply
DC 15...24 V (± 10%) (4-20 mA)
cable gland with strain relief Ø6 to 8 mm,
Cable Entry
½” conduit adapter included
Ambient Temperature
Passive -30°F to 210°F [-35°C to 100°C]
Active -30°F to 120°F [-35°C to 50°C]
Operating Temperature
01ST
Passive (01HT/01ST) -30°F to 210°F [-35°C to 90°C]
Active (22HT) -30°F to 160°F [-35°C to 70°C]
Includes pipe clamp (≤
( ø 4.33” [110 mm])
Degree of Protection
01ST NEMA 4, IP65 01HT & 22HT See accessories for larger pipe clamp:
01HT NEMA 4X, IP65 A-22P-A42 (≤ ø 9.84“ [250 mm])
cULus acc. to UL60730-1A/-2-6, CAN/
CSA E60730-1:02, CE acc. to 2014/30/EU,
RoHS acc. to 2011/65/EU, UL Enclosure
Type 4X
Agency Listing
cULus acc. to UL60730-1A/-2-9, CAN/CSA
E60730-1:02/-2-9, CE acc. to 2014/30/EU,

U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


RoHS acc. to 2011/65/EU, UL Enclosure
Type 4X

Pipe Sensor Nomenclature


Condensation

All prices are in US Dollars (USD)


22 H H - 5 0 0 X
Power Application Medium Region Signal Type Length Details
22 = Active H = Surface Mount (Housing) H = Condensation 5 = Americas 0 = Switch 0 = N/A X = Remote Cable Probe

Condensation sensor with LED indication has a SPDT switched contact


to prevent condensation on chilled beams or other cold surfaces. Also
available with 6.5’ [2m] cable.

Power Supply DC 15...24 V (±10%), AC 24 V (±10%)


cable gland with strain relief Ø6 to 8 mm,
Cable Entry
½” conduit adapter included
Ambient Temperature -5°F to 120°F [-20°C to 50°C]
Operating Temperature -5°F to 140°F [-20°C to 60°C] 22HH-500X
Degree of Protection NEMA 4X, IP65 Includes Mounting Ties
Agency Listing cULus acc. to UL60730-1A/-2-9, CAN/CSA
E60730-1:02/-2-9, CE acc. to 2014/30/EU, 22HH
RoHS acc. to 2011/65/EU, UL Enclosure
Type 4X

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

19-12
Pipe Sensor Product Range
Temperature / Condensation

Measuring Values Measuring Ranges


Additional
List Price
Temperature Features

-30°F to +130°F [-50°C to 50°C]

0°F to 250°F [-10°C to +120°C]

40°F to 240°F [0°C to 100°C]

30°F to 480°F [0°C to 250°C]


0°F to 100°F [-15°C to 35°C]

40°F to 90°F [-20°C to 80°C]

40°F to 140°F [0°C to 50°C]

0°F to 150°F [0°C to 160°C]


Output Signals

Cable Length
Multirange
(default)

[m]

SENSORS
Temperature
01ST-5A3 PT100 6.5 ft. [2] $40
01ST-5B3 PT1000 6.5 ft. [2] $40
01ST-5E3 Ni1000 6.5 ft. [2] $40
Passive
01ST-5L3 NTC10k2 6.5 ft. [2] $30
01ST-5M3 NTC10K3 6.5 ft. [2] $30
01ST-5Q3 NTC20K 6.5 ft. [2] $30
01HT-5A PT100 $56
01HT-5B PT1000 $56
01HT-5E Ni1000 $56
Passive
01HT-5L NTC10k2 $44
01HT-5M NTC10K3 $44
01HT-5Q NTC20K $44
22HT-52 DC 0-5V (DC 0-10V) 8         $162
Active
22HT-54 4-20 mA 8         $162
• Factory setting (setting ranges are configurable on the sensor).
Please note: For temperature and humidity sensors, the °F and °C are not direct conversions. °F is the standard range for the United States, and °C is the standard range for
Canada and Latin America.

Active selectable measuring ranges are for application and scaling purposes, please ensure installation is within stated ambient and operating temperature range.
U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

Measuring Values
Additional Features List Price
All prices are in US Dollars (USD)

Cable Length [m]


Output Signals

Remote Probe
(default)

Condensation
22HH-50 SPDT $214
Switch
22HH-500X SPDT 6.5 ft. [2]  $234

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN


19-13
Pipe Sensor Nomenclature
Pressure

22 W P - 5 1 1
Power Application Medium Region Signal Type Range
22 = Active W = Water P = Pressure 5 = Americas 1 = VDC (Volt) 1 = 0 to 15 psi
3 = 4-20 mA 4 = 0 to 50 psi
6 = 0 to 100 psi
7 = 0 to 200 psi

Pressure sensors incorporate stainless steel strain gauge technology


to measure liquids and provide gauge pressure readings for a wide
variety of applications in industrial process and HVAC controls.
SENSORS

Accuracy ±0.5% Full Scale @ 77°F [25°C]


Power Supply DC 15...24 V (±10%), AC 24 V (±10%)
mvs plug according to DIN EN175301-
Cable Entry
803 / type A
Thread/Port Connection ¼” NPT (external) A-22WP-A01 Adaptor
¼” NPT to ½” NPT
Ambient Temperature -40°F to 220°F [-40°C to 105°C]
Operating Temperature -40°F to 255°F [-40°C to 125°C]
Degree of Protection NEMA 4, IP65 22WP

Pipe Sensor Nomenclature


Differential Pressure

22 W DP - 5 1 1

U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


Power Application Medium Region Signal Type Range
22 = Active W = Water DP = Differential Pressure 5 = Americas 1 = VDC (Volt) 1 = 0 to 15 psi
3 = 4-20 mA 2 = 0 to 30 psi

All prices are in US Dollars (USD)


4 = 0 to 50 psi
5 = 0 to 100 psi

Differential pressure sensors measure water and or non-aggressive


gases are used with the building management system (BMS) to
maintain adequate air or water pressure to critical zones.

<±1% of measuring range @ 23°F to


Accuracy
167 °F [-5°C to 75°C]
Power Supply DC 15...24 V (±10%), AC 24 V (±10%)
angle plug according to DIN 43650,
Cable Entry
construction A See Accessories for
Ambient Temperature 15°F to 120°F [-10°C to 50°C] ¼” NPT brass and
Operating Temperature 15°F to 175°F [-10°C to 80°C] stainless steel pipe
adaptors
Thread/Port Connection ¼” NPT (internal)
22WDP
Degree of Protection NEMA 4, IP65

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

19-14
Pipe Sensor Product Range
Pressure / Differential Pressure

Measuring Values Measuring Range


List Price
Pressure

Output Signals

0 to 100 psi

0 to 200 psi
0 to 15 psi

0 to 50 psi

SENSORS
Gauge Pressure
22WP-511 DC 0-10V  $333
22WP-514 DC 0-10V  $333
22WP-516 DC 0-10V  $333
22WP-517 DC 0-10V  $333
Active
22WP-531 4-20 mA  $333
22WP-534 4-20 mA  $333
22WP-536 4-20 mA  $333
22WP-537 4-20 mA  $333

Measuring Values Measuring Range


List Price
Pressure
U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.
All prices are in US Dollars (USD)

Output Signals

0 to 100 psi
0 to 15 psi

0 to 30 psi

0 to 50 psi

Differential Pressure
22WDP-511 DC 0-10V  $832
22WDP-512 DC 0-10V  $832
22WDP-514 DC 0-10V  $832
22WDP-515 DC 0-10V  $832
Active
22WDP-531 4-20 mA  $832
22WDP-532 4-20 mA  $832
22WDP-534 4-20 mA  $832
22WDP-535 4-20 mA  $832

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN


19-15
Pipe Sensor Nomenclature
Flow

FM 050
Valve Size Pressure Rating
FM = Flow Meter 050 = ½” Blank = 360 psi (½” to 2”)
075 = ¾” ANSI 125 (2½” to 6”)
100 = 1” -250 = ANSI 250 (2½” to 6”)
125 = 1¼”
150 = 1½”
200 = 2”
250 = 2½”
300 = 3”
400 = 4”
SENSORS

500 = 5”
600 = 6”

Flow meters utilizes ultrasonic technology with glycol and temperature


compensation to accurately measure water flow for HVAC plant
applications and sub-metering of hot or chilled water flow.

Power Supply 24 VAC/DC


cable connection with 3ft. [1 m], 18 GA
Cable Connection
appliance cable
Degree of Protection NEMA 2, IP54
chilled or hot water, up to 60% glycol max,
Service condenser water (open loop/steam not
allowed)
End Fitting NPT female inlet, NPT male outlet
Sensor Housing forged brass, nickel plated, or cast iron

U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


Sensor Housing Pressure
360 psi, ANSI 125, or ANSI 250
Ratng
Media Temp. Range -4°F to +250°F [-20°C to +120°C]
Ambient Temp. Range -22°F to +122°F [-30°C to +50°C]
Inlet Length to Meet FM
inlet: 5x nominal pipe size (NPS) Flow Meter
Specified Measurement

All prices are in US Dollars (USD)


outlet: no requirement
Accuracy
ultrasonic with glycol and temperature
Flow Sensor Technology
compensation
Output Signal analog (0 to 10 VDC)
0V sensor has no supply voltage
sensor has supply voltage but is in
0.3V
error state
0.5V 0% of V’nom*
10V 100% of V’nom*
Flow Measurement
+2%**
Tolerance
Flow Measurement
+0.5%
Repeatability
Agency Listing cULus: UL 94 D5 E108966, UL Enclosure
Type 2

*V’nom is the maximum/nominal flow rate for each size


**See data sheet for Accuracy information

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

19-16
Pipe Sensor Product Range
Flow

Measuring Values
Body Pressure
Flow (GPM) Valve Size List Price
Rating (psi)

Output Signals

Inches [mm]
1.52 - 152.0

2.15 - 215.0

3.80 - 380.0

5.94 - 594.0

8.55 - 855.0
0.13 - 12.4

0.22 - 21.8

0.35 - 34.2

0.48 - 47.5

0.92 - 91.2
0.07 - 6.6

ANSI 125

ANSI 250
360 psi

SENSORS
Flow Meters
FM050 DC 0-10V   ½” [15] $598
FM075 DC 0-10V   ¾” [20] $606
FM100 DC 0-10V   1” [25] $801
NPT

FM125 DC 0-10V   1¼” [32] $1,243


FM150 DC 0-10V   1½” [40] $1,335
FM200 DC 0-10V   2” [50] $1,541
FM250 DC 0-10V   2½” [65] $6,040
FM250-250 DC 0-10V   2½” [65] $7,852
Active
FM300 DC 0-10V   3” [80] $6,631
FM300-250 DC 0-10V   3” [80] $8,620
Flanged

FM400 DC 0-10V   4” [100] $7,141


FM400-250 DC 0-10V   4” [100] $9,283
FM500 DC 0-10V   5” [125] $7,781
FM500-250 DC 0-10V   5” [125] $10,115
FM600 DC 0-10V   6” [150] $8,384
FM600-250 DC 0-10V   6” [150] $10,899
U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.
All prices are in US Dollars (USD)

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN


19-17
Outdoor Air Sensor Nomenclature
Temperature

22 U T - 5 A
Power Application Medium Region Signal Type
01 = Passive U = Outside T = Temperature 5 = Americas 2 = VDC (Volt) Multi Range
22 = Active 4 = 4-20 mA Multi Range
A = PT100
B = PT1000
E = Ni1000
L = NTC10k2
M = NTC10k3
SENSORS

Q = NTC20k

Outdoor air mounted temperature sensors designed to measure the


outside temperature for efficient heating/cooling automation. Equipped
with a NEMA 4X / IP65 rated enclosure, snap cover and mounting
plate for ease of installation. Available with passive or with an external
probe version for active outputs and compatible to major building
automation systems.

Accuracy
Temperature
PT.. = ±0.5°F @ 32°F [±0.3°C @ 0°C] 01UT
01UT Ni.. = ±0.7°F @ 32°F [±0.4°C @ 0°C] Includes Mounting Plate
NTC.. = ±0.3°F @ 77°F [±0.2°C @ 25°C]
22UT ±1% of upper selected measuring range
DC 15...24 V (±10%), AC 24 V (±10%)
Power Supply
DC 15...24 V (±10%), (4...20 mA)
cable gland with strain relief Ø6 to 8 mm,
Cable Entry
½” conduit adapter included
Ambient Temperature

U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


Passive(01UT) -30°F to 120°F [-35°C to 50°C]
Active (22UT) -30°F to 120°F [-35°C to 50°C]
Operating Temperature
Passive(01UT) -30°F to 120°F [-35°C to 50°C]
Active (22UT) -30°F to 120°F [-35°C to 50°C]

All prices are in US Dollars (USD)


Degree of Protection NEMA 4X, IP65
22UT
Agency Listing cULus acc. to UL60730-1A/-2-9, CAN/CSA
Includes Mounting Plate
E60730-1:02/-2-9, CE acc. to 2014/30/EU,
RoHS acc. to 2011/65/EU, UL Enclosure
Type 4X

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

19-18
Outdoor Air Sensor Product Range
Temperature

Measuring Values Measuring Ranges


Additional
List Price
Measuring Range Temperature Features

-30°F to +130°F [-50°C to +50°C]


30°F to 130°F [-50°C to +50°C]

0°F to 250°F [-10°C to +120°C]


0°F to 100°F [-15°C to +35°C]

40°F to 90°F [-20°C to +80°C]


30°F to 480°F [0°C to 250°C]

40°F to 240°F [0°C to 100°C]


0°F to 150°F [0°C to 160°C]
Output Signal Temperature

Probe Length [mm]

SENSORS
Multirange
(default)

Outdoor Air
01UT-5A PT100 $73
01UT-5B PT1000 $73
01UT-5E Ni1000 $66
Passive
01UT-5L NTC10k2 $47
01UT-5M NTC10K3 $47
01UT-5Q NTC20K $47
22UT-52 DC 0-5V (DC 0-10V) 8         1" [25] $174
Active
22UT-54 4-20 mA 8         1" [25] $174

• Factory setting (setting ranges are configurable on the sensor).


Please note: For temperature and humidity sensors, the °F and °C are not direct conversions. °F is the standard range for the United States, and °C is the standard range for Canada and Latin America.

Active selectable measuring ranges are for application and scaling purposes, please ensure installation is within stated ambient and operating temperature range.
U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.
All prices are in US Dollars (USD)

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN


19-19
Outdoor Air Sensor Nomenclature
Temperature / Humidity

22 U TH - 5 1 0 X
Power Application Medium Region Signal Type Length Details
22 = Active U = Outside TH = Temperature & Humidity 5 = Americas 1 = VDC (Volt) 0 = N/A X = Weather Shield
3 = 4-20 mA B = PT1000
5 = Modbus E = Ni1000 JCI
6 = BACnet L = NTC10k2
M = NTC10k3
Q = NTC20k
Outside air mounted combined humidity and temperature sensors
with selectable relative humidity, absolute humidity, dewpoint and
enthalpy outputs. Optional BACnet and Modbus communications and
SENSORS

optional weather/sun shield.

Accuracy
Temperature
Active ±0.9°F @ 70°F [±0.5°C @ 21°C]
Passive, PT ±0.5°F @ 32°F [±0.3°C @ 0°C]
Passive, Ni ±0.7°F @ 32°F [±0.4°C @ 0°C]
Passive, NTC ±0.3°F @ 77°F [±0.2°C @ 25°C]
±2% between 10 to 90% RH @ 70°F
Humidity
[21°C] 22UTH
DC 15...24 V (±10%), AC 24 V (±10%) Includes Rain Protector and
Power Supply
DC 15...24 V (±10%), (4...20 mA) Mounting Plate
cable gland with strain relief Ø6 to 8 mm,
Cable Entry 22UTH
½” conduit adapter included
with weather shield
Ambient Temperature -30°F to 120°F [-35°C to 50°C]
Operating Temperature -30°F to 120°F [-35°C to 50°C]
Degree of Protection NEMA 4X, IP65
Agency Listing cULus acc. to UL60730-1A/-2-9/-2-13,
CAN/CSA E60730-1:02/-2-9, CE acc. to
2014/30/EU, RoHS acc. to 2011/65/EU,
UL Enclosure Type 4X

U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


All prices are in US Dollars (USD)

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

19-20
Outdoor Air Sensor Product Range
Temperature / Humidity

Measuring Values
Measuring Range Relative Absolute Additional Features List Price
Dewpoint Enthalpy
Temperature Humidity Humidity

40°F to 140°F [0°C to 50°C] (default)


0 to 50 g/m³ (default) 0 to 80 g/m³
-40°F to +160°F [-40°C to +60°C]

0 to 100% RH (non condensing)


0°F to 200°F [-20°C to +80°C]

0°F to 100°F [-15°C to +35°C]

0°F to 200°F [-20°C to +80°C]


40°F to 140°F [0°C to 50°C]
Output Signal Temperature

Output Signal Humidity

Communication

Weather Shield
0 to 85 kJ/kg
Temperature

Multirange
(default)

(default)

SENSORS
Outdoor Air
22UTH-51 DC 0-5V (DC 0-10V) DC 0-5V (DC 0-10V) 4         $410
Active
22UTH-53 4-20 mA 4-20 mA 4         $410
22UTH-510B PT1000 DC 0-5V (DC 0-10V)     $410
22UTH-510E Ni1000 DC 0-5V (DC 0-10V)     $410
22UTH-510L NTC10k2 DC 0-5V (DC 0-10V)     $410
22UTH-510M NTC10K3 DC 0-5V (DC 0-10V)     $410
22UTH-510Q NTC20K DC 0-5V (DC 0-10V)     $410
Passive
22UTH-530B PT1000 4-20 mA     $410
22UTH-530E Ni1000 4-20 mA     $410
22UTH-530L NTC10k2 4-20 mA     $410
22UTH-530M NTC10K3 4-20 mA     $410
22UTH-530Q NTC20K 4-20 mA     $410
22UTH-510X DC 0-5V (DC 0-10V) DC 0-5V (DC 0-10V) 4          $480
22UTH-530X 4-20 mA 4-20 mA 4          $480
Active
22UTH-550X DC 0-5V (DC 0-10V) DC 0-5V (DC 0-10V)     Modbus RTU  $600
22UTH-560X DC 0-5V (DC 0-10V) DC 0-5V (DC 0-10V)     BACnet MS/TP  $600
• Factory setting (setting ranges are configurable on the sensor).
Please note: For temperature and humidity sensors, the °F and °C are not direct conversions. °F is the standard range for the United States, and °C is the standard range for Canada and Latin America.
U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

Active selectable measuring ranges are for application and scaling purposes, please ensure installation is within stated ambient and operating temperature range.
All prices are in US Dollars (USD)

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN


19-21
Sensor Accessories
Air

22DCM
22DTM
22UTH

22DTH

22DCV
22DCK

22ADP
01DTS

22DTC

01APS
01MT
22MT

22HH

22DC
01DT

01UT
22UT

22DT
22CT
Model Number List Price

A-22AP-A01
• • $15
Metal duct connectors, L = 1.5” [40 mm]
A-22AP-A03
Metal duct connectors, L = 4” [100 mm]
• • $22

A-22AP-A05.1
PVC tube 6.5 ft. [2 m] and 2 plastic duct probes 4”
• • $15
[100mm] for 01APS/22ADP pressure switch/sensor
(multipack- 50pcs)
SENSORS

A-22AP-A08
PVC tube 6.5 ft. [2 m] and 2 plastic duct probes 4” • • $21
[100mm] for 01APS/22ADP pressure switch/sensor
A-22D-A03
Mounting flange for duct temperature sensors
Ø ¼” [6 mm] • • $9

A-22D-A05
Brass mounting flange for duct temperature
• • $22
sensors, up to 500°F [260°C]

A-22D-A06
Replacement filter for humidity sensors • • • • • • $21

A-22D-A08
Mounting kit for duct averaging and low temp limit • • • $16
detection

A-22D-A09
Mounting plate for sensors with small housing
• • • • • • • • $7

U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


A-22D-A10
Mounting plate for sensors with large housing
• • • • • • • • $8

A-22D-A11

All prices are in US Dollars (USD)


Mounting clip for duct temperature • • • • • $3

A-22D-A34
Mounting flange for duct humidity and CO2 sensor
• • • • • • • $15

A-22G-A04.1
½” NPT conduit adaptor
• • • • • • • • • • • • • • • • • • $52
(Pack of 10)

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

19-22
Sensor Accessories
Water

22WDP
22WP
01DT

22DT

01HT
01ST
Model Number List Price

A-22P-A05
• • $28
Thermowell (2 part) stainless steel 2” [50 mm] ½” NPT
A-22P-A07
• • $29
Thermowell (2 part) stainless steel 4” [100 mm] ½” NPT
A-22P-A09
• • $35
Thermowell (2 part) stainless steel 6” [150 mm] ½” NPT
A-22P-A11
• • $44
Thermowell (2 part) stainless steel 8” [200 mm] ½” NPT
A-22P-A13
• • $67
Thermowell (2 part) stainless steel 12” [300 mm] ½” NPT
A-22P-A15
• • $90
Thermowell (2 part) stainless steel 18” [450 mm] ½” NPT

SENSORS
A-22P-A17
• • $20
Thermowell (2 part) brass 2” [50 mm] ½” NPT
A-22P-A19
• • $24
Thermowell (2 part) brass 4” [100 mm] ½” NPT
A-22P-A21
• • $29
Thermowell (2 part) brass 6” [150 mm] ½” NPT
A-22P-A23
• • $35
Thermowell (2 part) brass 8” [200 mm] ½” NPT
A-22P-A25
• • $52
Thermowell (2 part) brass) 12” [300 mm] ½” NPT
A-22P-A27
• • $65
Thermowell (2 part) brass 18” [450 mm] ½” NPT
A-22P-A36
• • $94
Thermowell (machined) stainless steel 2” [50 mm] ½” NPT
A-22P-A37
• • $125
Thermowell (machined) stainless steel 4” [100 mm] ½” NPT
A-22P-A38
• • $129
Thermowell (machined) stainless steel 6” [150 mm] ½” NPT
A-22P-A39
• • $147
Thermowell (machined) stainless steel 8” [200 mm] ½” NPT
U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

A-22P-A40
Fixing strap with thermal paste for pipes up to Ø 1.6...4.3” • • $11
[40...110 mm]
A-22P-A42
All prices are in US Dollars (USD)

Fixing strap with thermal paste for pipes up to Ø 1.6...9.8” • • $20


[40...250 mm]
A-22P-A44
• • • • $7
Thermal contact fluid 0.04 oz [1.2 ml]
A-22WP-A01
Adapter ¼” NPT to ½” NPT • $22

A-22WP-A03
Adapter connection set 6 mm ¼” NPT brass (2x) • $33

A-22WP-A05
• $146
Adapter connection set 6 mm ¼” NPT stainless steel (2x)
A-22WP-A07
• $37
Adapter connection set 8 mm ¼” NPT brass (2x)
A-22WP-A09
• $170
Adapter connection set 8 mm ¼” NPT stainless steel (2x)
A-22G-A04.1
½” NPT conduit adaptor • • • $52
(Pack of 10)

A-22P-A60
Brass compression fitting ¼” to ½” NPT adapter for
competitor retrofit applications of a thermowell with ½” NPT • • $10
internal thread, includes brass compression sleeve and optional
nylon sleeve

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

19-23
Small Devices,
Big Impact

Installation in a Snap
Belimo offers a complete range of sensors designed with a snap-on cover,
enabling easy installation while providing NEMA 4X/IP65 protection.

CESIM. Small Devices, Big Impact.


Comfort | Energy Efficiency | Safety | Installation | Maintenance

Find out more


belimo.us/cesim
ECONOMIZER AND
RETROFIT SOLUTIONS
Energy Efficient Comfort
• Optimal indoor air quality with increased
energy efficiency.
• Innovative solutions offering quality and
reliability for your entire system.
• Quick and convenient replacement without RETROFIT SOLUTIONS
any interruption in service. ECONOMIZER,

Russ Brown, Product Manager


What you Need,
Delivered On-Time

Belimo Retrofit App


Poorly functioning or inoperative systems can be transformed by finding the right
replacement solution. The Retrofit App enables you to locate the appropriate replacement
product based on parameters such as manufacturer, model, voltage, torque, control type
and more. Belimo retrofit solutions are compatible with all major control systems and have
fast delivery to get you back in operation.
RETROFIT SOLUTIONS

Find the Belimo Retrofit App for free on iTunes or Google Play.
ECONOMIZER,

Discover the advantages


www.belimo.us

Google Play and the Google Play logo are trademarks of Google Inc.
20
ZIP ECONOMIZER
Fast Route to Reliable Energy Savings
• Display delivers clear live status information,
easy setup, changes, and operating history.
• Integrated on-board help for fast setup or
troubleshooting.
• Compliant with the most recent energy
codes and standards (ASHRAE 90.1-2016,
IECC-2015, California Title 24-2016).

BACnet® is a registered trademark of ASHRAE. Justin Lindstrom, Digital Applications Manager


Selection Guide
ZIP Economizer

AND

ECON-ZIP-BASE ECON-ZIP-10K
(Supply Air Sensor)
ECONOMIZER SOLUTIONS

TFB24-SR LF24-SR US NFB24-SR AFB24-SR


up to 7.5 Tons 7.5-12 Tons 12-15 Tons 15-30 Tons

SINGLE DRY BULB DIFFERENTIAL DRY BULB SINGLE ENTHALPY DIFFERENTIAL ENTHALPY

OR

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


All prices are in US Dollars (USD)
ECON-ZIP-10K ECON-ZIP-TH

• Demand Control Ventilation (DCV)* - ECON-ZIP-EM + CO2 sensor • Remote Diagnostic Alarm Notification* - ECON-ZIP-COM
of your choice (0-2000 PPM, 0-10 VDC). • Required for BACnet MS/TP communication
• Preoccupancy Purge* - ECON-ZIP-EM
Requires thermostat with purge setting and contacts. * May be required by local codes

• Remote Damper Override - ECON-ZIP-EM + SGA24


• Exhaust Fan - ECON-ZIP-EM
• 2 Speed fan control or remote diagnostic alarm notification - ECON-ZIP-EM

See page 20-4 for a list of ZIP Pack Solutions & Retrofit Kits.
Learn More: www.belimo.us
BACnet® is a registered trademark of ASHRAE.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

20-1
Zip Economizer Product Range

Specifications
Power Supply 24 VAC ±20%, 50/60 Hz, class 2 power
4 VA base control (ECON-ZIP-BASE)
5.5 VA base control with Energy Module
(ECON-ZIP-BASE + ECON-ZIP-EM)
Power Consumption* 5 VA base control with Communication Module
(ECON-ZIP-BASE + ECON-ZIP-COM)
6.5 VA base control with Energy Module and
Communication Module.
NTC 10K-2 Thermistor
Supported Temperature Sensor
sensor auto-detection
Supported Humidity Sensor 0-10 VDC; sensor auto-detection
Supported CO2 Sensor 0-10 VDC; sensor auto-detection
Environmental RoHS, conformally coated
Ambient Temperature -40°F to +158°F [-40°C to +70°C]
Storage Temperature -40°F to +176°F [-40°C to +80°C]
Humidity 5 to 95% R.H. (non-condensing)
Wiring ¼” male spade connectors
Housing Material UL94-5VA
Housing NEMA 1
Display 2x16 character LCD display; LED backlight
Display Operating Temperature** -22°F to +176°F [-30°C to +80°C]
EMC according to UL60730-1, cULus according
Agency Listings
to UL873, CAN/CSA C22.2, No. 24-93, IECC
Energy Code Compliant ASHRAE 90.1, CA Title 24, NECB

ECONOMIZER SOLUTIONS
*The power consumption is for the control only and does not include connected loads
such as actuator, compressors, fans, and sensors. MODEL List Price
**At low temperatures the display has decreased response time. Below -22°F [-30°C] ECON-ZIP-BASE $496
it will not function.

FAIL-SAFE ACTUATORS***
Power Running Time(s)
Model # Torque Control Input Feedback VA Rating List Price
Supply
AFB24-SR 180 in-lbs [20 Nm] 2-10 VDC 2-10 VDC 24 VAC/DC 95 seconds <20 seconds 8.5 $694
NFB24-SR 90 in-lbs [10 Nm] 2-10 VDC 2-10 VDC 24 VAC/DC 95 seconds <20 seconds 6 $609
LF24-SR US 35 in-lbs [4 Nm] 2-10 VDC 2-10 VDC 24 VAC/DC 150 seconds <25 seconds 5 $520
TFB24-SR 22 in-lbs [2.5 Nm] 2-10 VDC 2-10 VDC 24 VAC/DC 95 seconds <25 seconds 4 $442
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

*** Up to three actuators can be used. Visit www.belimo.us for details.


Belimo fail-safe actuators must be used to facilitate faster commissioning procedures (-SR acceptable).

Accessories List Price


All prices are in US Dollars (USD)

ECON-ZIP-TH
The ECON-ZIP-TH Sensor may be used to measure temperature and humidity in the outdoor or return air stream. The temperature and humidity
output is via 2 discrete analog channels that can be independently measured with a multimeter. One sensor is used in the outdoor air intake for single
$171
enthalpy changeover strategy. An additional sensor can be added in the return air stream for differential enthalpy changeover strategy.

Note: When using the ECON-ZIP-TH it is not necessary to use a separate temperature sensor ECON-ZIP-10K for outdoor air (OAT), return air (RAT).

ECON-ZIP-10K
The ECON-ZIP-10K allows for reliable air temperature readings. The sensor may be used for outdoor air (OAT), return air (RAT), or supply air
(SAT) temperature measurements and control, with no configuration required. A minimum of one SAT and one OAT sensor is required for the ZIP $34
Economizer to function. An RAT sensor can be added for differential temperature change over strategy. For best control results, sensors should be
placed in the air stream. The T-Bracket mounting is universal and can be inserted through the ductwork, fan housing or surface mounted.

22DC-51 Carbon Dioxide (CO2)Sensor


The 22DC-51 Carbon Dioxide (CO2) air quality sensor may be incorporated to further increase energy savings and occupant comfort through
Demand Control Ventilation (DCV). By directly measuring CO2 concentration levels in the served space the outside air damper position will modulate
$540
to accommodate for changes in space occupancy (CO2).

ECON-ZIP-EM required for Demand Control Ventilation functionality.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

20-2
Optional Add-On Modules
ZIP Economizer

Accessories List Price

ECON-ZIP-EM
The ZIP Economizer Energy Module provides additional I/Os to offer higher control functionalities that will save even more energy. The Energy
Module is needed for demand control ventilation, indoor fan- 2 speed control or remote diagnostic alarm notification, power exhaust fan, remote
override for damper positioning, and preoccupancy purge. The auto-detection and plug and play capability offers quick set up.

Technical Data
Type Name Description Electrical Specification
CO2 sensor requires CO2 sensor capable of
Input CO2 + input for DCV 0-10 VDC signal representing
0-2000 ppm. (not supplied)
Remote 24 VAC output (1.5A max.)
diagnostic impedance for IF auto detection @
Output* ALM/IF alarm/indoor 24 VAC:
fan low speed <600 Ω @ 60 Hz
enable <800 Ω @ 50 Hz $113
24 VAC output (1.5A max.)
impedance for auto detection @
Exhaust fan
Output EF 24 VAC:
enable
<600 Ω @ 60 Hz
<800 Ω @ 50 Hz
Preoccupancy
on/off, 24 VAC, 50/60 Hz
Input AUX1 ± purge contact
current load min. 10mA
input
ECONOMIZER SOLUTIONS

Remote
damper 2-10 VDC signal represents 0-100%
Input** AUX2 ±
override input damper position

*IF output is configured via the Settings menu (default output is remote diagnostic alarm).
** Use remote override potentiometer; Belimo part number SGA24 or SGF24.

ECON-ZIP-COM
The ZIP Economizer Communication Module provides remote diagnostic alarm indication with future capabilities such as data trending and
building automation integration. Required for BACnet MS/TP communication.

Technical Data
Type Name Description Electrical Specification
RS485 Interface
Optical isolation max. 1k VDC $176

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


Communication (for max. 1 min.)
I/O RS-485 Terminal assignments:
interface
(+) Data B
(-) Data A
GND Ground
Relay contact 24V

All prices are in US Dollars (USD)


Diagnostic
Relay ALM Normal current: 0.5A
alarm
BACnet® is a registered Inrush current: 1A
trademark of ASHRAE.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

20-3
Retrofit Kits and ZIP Packs
ZIP Economizer

Components
Retrofit Kits for Honeywell Foot Mounted Actuators (Belimo and Honeywell actuator shown for reference only) List Price
(# included in kit)
ECON-ZIP-ACT Shaft, M4x8 Screws (4),
Actuator shaft adapter allows easy retrofi t from Honeywell® black box motors Locking Nuts (4)
(M7XXX) to Belimo fail-safe actuator. $67

ECON-ZIP-LF1 ECON-ZIP-ACT, ZG-112, Screws


Bracket with hole patterns to mount the LF series actuator, horizontal or vertical
position to meet space requirements. $96

ECON-ZIP-TF1 ECON-ZIP-ACT, ZG-113, Spacers


Bracket with hole patterns to mount the TF series actuator, horizontal or vertical and Screws
position to meet space requirements. $96

Components
ZIP Packs List Price
(# included in kit)
ECON-ZIP-SDTF ECON-ZIP-BASE, ECON-ZIP-EM,
Single Dry Bulb with DCV capability and TF fail-safe actuator (22 in-lbs) ECON-ZIP-10K (2), TFB24-SR,
ECON-ZIP-TF1 $1,042

ECONOMIZER SOLUTIONS
ECON-ZIP-DDTF ECON-ZIP-BASE, ECON-ZIP-EM,
Differential Dry Bulb with DCV capability and TF fail-safe actuator (22 in-lbs) ECON-ZIP-10K (3), TFB24-SR,
ECON-ZIP-TF1 $1,066

ECON-ZIP-SETF ECON-ZIP-BASE, ECON-ZIP-EM,


Single Enthalpy with DCV capability and TF fail-safe actuator (22 in-lbs) ECON-ZIP-10K, ECON-ZIP-TH,
TFB24-SR, ECON-ZIP-TF1 $1,147

ECON-ZIP-DETF ECON-ZIP-BASE, ECON-ZIP-EM


Differential Enthalpy with DCV capability and TF fail-safe actuator(22 in-lbs) ECON-ZIP-10K, ECON-ZIP-TH (2)
TFB24-SR, ECON-ZIP-TF1 $1,261
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

ECON-ZIP-SDLF ECON-ZIP-BASE, ECON-ZIP-EM,


Single Dry Bulb with DCV capability and LF fail-safe actuator (35 in-lbs) ECON-ZIP-10K (2), LF24-SR US,
ECON-ZIP-LF1
All prices are in US Dollars (USD)

$1,100

ECON-ZIP-DDLF ECON-ZIP-BASE, ECON-ZIP-EM,


Differential Dry Bulb with DCV capability and LF fail-safe actuator (35 in-lbs) ECON-ZIP-10K (3), LF24-SR US,
ECON-ZIP-LF1 $1,124

ECON-ZIP-SELF ECON-ZIP-BASE, ECON-ZIP-EM,


Single Enthalpy with DCV capability and LF fail-safe actuator(35 in-lbs) ECON-ZIP-10K, ECON-ZIP-TH,
LF24-SR US, ECON-ZIP-LF1 $1,204

ECON-ZIP-DELF ECON-ZIP-BASE, ECON-ZIP-EM


Differential Enthalpy with DCV capability and LF fail-safe actuator (35 in-lbs) ECON-ZIP-10K, ECON-ZIP-TH (2)
LF24-SR US, ECON-ZIP-LF1 $1,318

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

20-4
Retrofit Solutions, Economizer Actuators
Retrofit Replacement Solutions

Retrofit Replacement Solutions - Honeywell M8405 Actuator List Price

Logic Module Bracket M8405 Actuator


The three-position control functionality of the LF24-SR-E US allows direct replacement of a Honeywell M8405A
ZG-112
foot mounted economizer actuator.

LF24-SR-E US
$562
35 in-lb fail-safe actuator, 2-10V, 24 VAC with minimum position selection

ZG-LF112
$64
Crank arm adaptor kit - includes KH-LF crank arm and clip, ZG-112 bracket and mounting hardware.

20477-00001
$64
Logic module bracket for Honeywell
KH-LF
crank arm KG6
$21
Ball joint (if needed)

Retrofit Replacement Solutions - Honeywell M7415 Actuator List Price


M7415 Actuator
M7415 The proportional control of a mixed air set point of the LF24-ECON-RO3 US allows direct replacement of a Honeywell
M7415 economizer actuator.
ECONOMIZER SOLUTIONS

W7459 LF24-ECON-R03 US
$591
35 in-lb fail-safe actuator, 24 VAC, 3K Ω thermistor

ZG-ECON1
$108
Includes ZG-112, KH-LF, 20477-00001 (logic module bracket), KG6 (ball joint), and 4 male spade connectors.

ZG-ECON2
$86
Includes ZG-112, KH-LF, KG6 (ball joint), and 4 female spade connectors.
Choose either ZG-ECON1 or ZG-ECON2.

Retrofit Replacement Solutions - Honeywell M7215 Actuator List Price

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


Logic Module Bracket M7215 Actuator
The proportional control of a mixed air set point of the LF24-SR US allows direct replacement of a Honeywell M7215
ZG-112
economizer actuator.

All prices are in US Dollars (USD)


LF24-SR US
$520
35 in-lb fail-safe actuator, 2-10V, 24 VAC

ZG-ECON1
$108
Includes ZG-112, KH-LF, 20477-00001 (logic module bracket), KG6 (ball joint), and 4 male spade connectors.
KH-LF
crank arm

Note: For economizer retrofit, please visit www.belimo.us

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

20-5
21
RETROFIT SOLUTIONS
Increasing Performance and
Efficiency
• Quickly and conveniently restores
applications without any interruption
in service.
• Custom solutions are available with our
in-house retrofit shop with lead times of
5 days or less.
• Simple way to implement Belimo actuators
in existing buildings whether electronic or
pneumatic.

Joseph Carcare, Product Manager


Retrofit Solutions Nomenclature

U F L K XXXX AFB 24 -MFT


Series Valve Type Retrofit Type Packaging Actuator Type Power Supply Control
U = Universal F = Butterfly L = Linkage K = Kit Dependent upon Non Fail-Safe 24 = 24 VAC/DC Blank = On/Off
S = Schneider G = Globe V = Valve L = Linkage valve you are LVB, LVX 120 = 120 VAC -3-X1 = On/Off,
W = Warren B = Ball SP = Special Order Blank with SP selecting to retrofit SVB, SVX
Floating Point
F = Flanged S = Short Stroke EVB, EVX
-SR = 2-10 VDC
RVB, RVX
Fail-Safe -MFT or MFT-X1
= Multi-Function
Spring Return
Technology
Nomenclature for example only. LF
All Belimo actuators are suitable for retrofit solutions NFB, NFX -MFT95-X1 =
depending on specific appliction parameters. 0-135 Ω
AFB, AFX
Electronic
LVKB, LVKX
SVKB, SVKX
AVKB, AVKX
GKB, GKX

“X” models are customizable. Refer to pages 21-14


and 21-45 for programming options.

Ordering Example

Select linkage solution


based on the Valve Siemens\Landis\Powers
Number, Configuration, 658 Series Valves
1 and Size; select the Linkage/Actuator Selection Guide
proper Linkage Solution
Belimo
for your valve. Valve Body Model
Valve
Size Fail-safe Close-Off psi Actuator Series
Belimo
Configuration Linkage

658 Series 2-way 1¼” No 78 LM UGLK1350


Example: Siemens Series #658, 156 NM UGLK1350
2-Way, 1¼” valve to be retrofitted. 236 SV UGVL
Choose correct kit UGLK1214 250 AM UGLK1214
or UGVL. Yes 61 LF UGLK1350
156 NF UGLK1214
236 SVK UGVL
Verify close-off is suitable 250 AF UGLK1214
for application.
2 Looking at the UGLK or
UGVL, the AF and SVK Series
actuator will provide 200 psi BASIC PRODUCTS
close-off for the 1¼” valve.
Running Time(s)
Power Auxiliary
Control Input Feedback VA Rating
Supply Switch
Model

AFB24 On/Off - 24 VAC/DC <75 seconds 20 secs 7.5 -
AFB24-S On/Off - 24 VAC/DC <75 seconds 20 secs 7.5 Built-In
AFBUP On/Off - 24-240 VAC <75 seconds 20 secs 8.5 -
Select actuator based on AFBUP-S On/Off - 24-240 VAC <75 seconds 20 secs 8.5 Built-In

needed control type. AFB24-SR 2-10 VDC (4-20mA) 2-10 VDC 24 VAC/DC 95 seconds <20 secs 8.5 -
AFB24-SR-S 2-10 VDC (4-20mA) 2-10 VDC 24 VAC/DC 95 seconds <20 secs 8.5 Built-In
Decide between AFB24, AFB24-PC 0-10 V Phasecut 2-10 VDC 24 VAC/DC 150 seconds <20 secs 10 -
3 AFB24-MFT AFB24-MFT 2-10 VDC (4-20mA) 2-10 VDC 24 VAC/DC 150 seconds <20 secs 10 -
AFB24-MFT-S 2-10 VDC (4-20mA) 2-10 VDC 24 VAC/DC 150 seconds <20 secs 10 Built-In
AFB24-MFT95 0 to 135 2-10 VDC 24 VAC/DC 150 seconds <20 secs 10 -
or SVKX24-3,
SVKB24-MFT.

Complete Ordering Example ACTUATOR PART # LVKX24-3 LVKB24-SR LVKX24-MFT SVKX24-3 SVKB24-SR SVKB24-MFT

Option One: Control type


On/Off,
Modulating Modulating/MFT
On/Off,
Modulating Modulating/MFT
4 Item 1: UGLK1214 Input signal / Feedback
Floating Point
- 2-10 VDC Variable
Floating Point
- 2-10 VDC Variable
Running time Motor 150 seconds 150 seconds Variable 150 seconds 150 seconds Variable
Item 2: AFB24-MFT Fail-Safe 35 seconds 35 seconds 35 seconds 35 seconds 35 seconds 35 seconds
Actuator travel 24mm 24mm 24mm 24mm 24mm 24mm

Complete Ordering Example Actuator noise level <45 dB(A) <45 dB(A) <45 dB(A) <45 dB(A) <45 dB(A) <45 dB(A)
GVL LINKAGES
Option Two: Universal Adjustable for
4 Item 1: UGVL+
UGVL
1/2” to 2”
$ $ $ $ $ $

SGVL Schnieder VB7..., VB9... $ $ $ $ $ $

SVKB24-MFT
Discontinued Belimo to Belimo
Actuator Replacement Cross Reference

FAIL-SAFE ACTUATORS
DISCONTINUED MODEL REPLACEMENT MODEL DISCONTINUED MODEL REPLACEMENT MODEL
AF120 US AFBUP FSAF230-S US FSAF230A-S
AF120-S US AFBUP-S FSAF24 US FSAF24A
AF230 US AFBUP FSAF24-BAL US FSAFB24-SR + SGA24 or SGF24
AF230-S US AFBUP-S FSAF24-BAL-S US FSAFB24-SR-S + SGA24 or SGF24
AF24 US AFB24 FSAF24-S US FSAF24A-S
AF24-3 US AFX24-MFT + F ❑ ❑ FSAF24-SR US FSAFB24-SR
AF24-3-S US AFX24-MFT-S + F ❑ ❑ FSAF24-SR-S US FSAFB24-SR-S
AF24-MFT US AFB24-MFT LF24-SR-MP US LF24-MFT-20 US
AF24-MFT95 US AFB24-MFT95 LF24-SR-S-MP US LF24-MFT-S-20 US
AF24-MFT-S US AFB24-MFT-S NF120 US NFBUP
AF24-PC US AFB24-PC NF120-S US NFBUP-S
AF24-PWM US AFX24-MFT + W ❑ ❑ NF230 US NFBUP
AF24-S US AFB24-S NF230-S US NFBUP-S
AF24-SR US AFB24-SR** NF24 US NFB24
AF24-SR US* AFB24-PC if phasecut is needed NF24-MFT US NFB24-MFT
AF24-SR95 US AFB24-MFT95 NF24-S US NFB24-S
AF24-SR-S US AFB24-SR-S** NF24-S2 US NFB24-S
AFA24-SR US** AFB24-SR** NF24-SR US NFB24-SR
AFR120 US AFBUP NF24-SR-S US NFB24-SR-S
AFR120-S US AFBUP-S SF120 US AFBUP
AFR24 US AFB24 SF120-S US AFBUP-S
AFR24-3 US AFX24-MFT + F ❑ ❑ SF24 US AFB24
AFR24-3-S US AFX24-MFT-S + F ❑ ❑ SF24-S US AFB24-S
AFR24-S US AFB24-S TF120 US TFB120
AFR24-SR US AFB24-SR** TF120-S US TFB120-S
FM24 US AFB24 TF24 US TFB24
FM24-SR US AFB24-SR TF24-3 US TFB24-3
FM24-SR90 US AFB24-MFT95 TF24-3-S US TFB24-3-S
FM24-SR95 US AFB24-MFT95 TF24-MFT US TFB24-MFT
FS24 AFB24 TF24-MFT-S US TFB24-MFT-S
FS24-S AFB24-S TF24-S US TFB24-S
FSAF120 US FSAF120A TF24-SR US TFB24-SR
FSAF120-S US FSAF120A-S TF24-SR-S US TFB24-SR-S

RETROFIT SOLUTIONS
FSAF230 US FSAF230A TFC120-S US TFCB120-S
* Purchased before May 2003. ** Not piggy back capable.
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

NON FAIL-SAFE ACTUATORS


DISCONTINUED MODEL REPLACEMENT MODEL DISCONTINUED MODEL REPLACEMENT MODEL
AM24 US AMB24-3 LM24-SR-T US LMB24-SR-T
All prices are in US Dollars (USD)

AM24-MFT 95 US AMX24-MFT95 + # AM0L0 1C1 R01 LM24-SR-T.1 US LMB24-SR-T.1


AM24-MFT US AMX24-MFT + # AM100 1C1 ❑ ❑ ❑ LM24-SR-T-2.0 US LMB24-SR-T
AM24-PC US AMX24-PC + # AM0N0 1C1 ❑ ❑ ❑ LMC24-SR US LMCB24-SR
AM24-PWM-A US AMX24-MFT + # AM100 1C1 W02 NM24 EU NMB24-3
AM24-PWM-B US AMX24-MFT + # AM100 1C1 W03 NM24 US NMB24-3
AM24-PWM-C US AMX24-MFT + # AM100 1C1 W01 NM24-1 US NMB24-3
AM24-S US AMB24-3-S NM24-1/200 US NMX24-3 + # NM00 1C3 000
AM24-SR US AMB24-SR NM24-1/300 US NMX24-3 + # NM00 1C3 000
AM24-SRS-A US AMX24-MFT + # AM100 1C1 A04 NM24-MFT US NMX24-MFT + # NM100 1C1 ❑ ❑ ❑
AM24-SRS-B US AMX24-MFT + # AM100 1C1 A05 NM24-MFT.1 US NMX24-MFT + # NM100 1C1 ❑ ❑ ❑
AM24-SRS-C US AMX24-MFT + # AM100 1C1 A06 NM24-PWM US NMX24-MFT + # NM100 1C1 W ❑ ❑
GM24 US GMB24-3 NM24-SR US NMB24-SR
GM24-MFT US GMX24-MFT+ # GM110 1C1 ❑ ❑ ❑ NM24-SRS US NMX24-MFT + # NM100 1C1 A ❑ ❑
GM24-SR US GMB24-SR NMQ24-MFT US NMQX24-MFT + #NMQD00 1C1 ❑ ❑ ❑
GM24-SR US GMX24-PC if phasecut is needed NMV24-D US NMV-D3-MFT
LM24 US LMB24-3 NMV24-V US NMV-D3-MFT
LM24-3 US LMB24-3 SM24 US AMB24-3
LM24-MFT US LMX24-MFT + # LM100 1C1 ❑ ❑ ❑ SM24-S US AMX24-MFT + # AM110 1C1 ❑ ❑ ❑ + S1A/S2A
LM24-MFT.1 US LMX24-MFT+ # LM100 1C1 ❑ ❑ ❑ SM24-SR US AMB24-SR
LM24-SR US LMB24-SR SM24-SR US AMX24-PC if phasecut is needed
LM24-SR.1 US LMB24-SR.1 SM24-SR94 US AMX24-MFT95 + # AM0L0 1C1 R01
LM24-SR-2.0 US LMB24-SR SM24-SRS US AMX24-MFT + # AM100 1C1 A ❑ ❑
* Purchased before May 2003. ** Not piggy back capable. ❑ Placeholder for custom options.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

21-1
Discontinued Belimo to Belimo
Actuator Replacement Cross Reference

When replacing an actuator on a valve, whether Belimo or other manufacture, be sure to consider the application parameters. The new product may
not be the best fit for the application. For example, an existing MAR actuator mounted to a valve linkage. The direct replacement of the actuator would
be the PR series actuator. The MAR and the PR have different linkage construction. The linkage would also need to be replaced.
When retrofitting or replacing actuators, it is recommended to select the new product based on application parameters. This ensures the selected
actuator is fit for the application.
Please consult Belimo for assistance with valve actuator replacement.

FAIL-SAFE ACTUATORS NON FAIL-SAFE ACTUATORS


DISCONTINUED MODEL REPLACEMENT MODEL DISCONTINUED MODEL REPLACEMENT MODEL
AF24 US AFRB24 AM24 US ARB24-3
AF24-SR US AFRB24-SR AM24-MFT US ARX24-MFT + # AR100 RC1 ❑ ❑ ❑
AF24-3 US AFX24-MFT + F ❑ ❑ AM24-S US ARB24-S US
AF24-3-S US AFX24-MFT-S + F ❑ ❑ NM24 US ARB24-3
AF24-PWM US AFX24-MFT + W ❑ ❑ NM24-MFT US ARX24-MFT + # AR100 RC1A ❑ ❑
AF24-SR95 US AFB24-MFT95 NM24-SR US ARX24-SR + # AR030 RC1 ❑ ❑ ❑
AF24-SR-S US AFB24-SR-S NM24-SRS US ARX24-MFT + # AR100 RC1W ❑ ❑
LF24-SR-MP US LF24-MFT-20 US NR24-3 US** LRB24-3
LF24-SR-S-MP US LF24-MFT-S-20 US NR24-SR US** LRX24-MFT + # LR100 RC1 ❑ ❑ ❑
NVF24-MFT US SVKX24-MFT* or SVKB24-SR* NV24-3 US SVX24-3*
NVF24-MFT-E US SVKX24-MFT* or SVKB24-SR* NV24-MFT US SVX24-MFT* or SVB24-SR*
*New linkage required. NVG24-MFT US EVX24-MFT* or EVX24-3*
* New linkage required.
NON FAIL-SAFE ACTUATORS ❑ Placeholder for custom options.
** Consider ambient temperature for application.
DISCONTINUED MODEL REPLACEMENT MODEL
LR24 US LRB24-3 NON FAIL-SAFE – 24 VAC NON FAIL-SAFE – 24 VAC
LR24/200 US* LRX24-3 + # LR000 RC3 002 Torque Torque
LR24/300 US LRX24-3 + # LR000 RC3 002 DISCONTINUED MODEL REPLACEMENT MODEL
(in-lbs) (in-lbs)
LR24-1 US LRB24-3 MAR100B-24V 1,500 SY4-24* 3,560
LR24-1/200 US* LRX24-3 + # LR000 RC3 002 MAR160-B-24V 2,000 SY4-24* 3,560
LR24-1/300 US LRB24-3 + # LR000 RC3 002 MAR100BP-24V 1,800 SY4-24MFT* 3,560
LR24-3-1 US LRB24-3 MAR160-BP-24V 2,500 SY4-24MFT* 3,560
RETROFIT SOLUTIONS

LR24-3-1/200 US* LRX24-3 + # LR000 RC3 002 MAR250-60-24V 5,000 SY5-24* 4,450
LR24-3-1/300 US LRX24-3 + # LR000 RC3 002 MAR250-60P-24V 5,000 SY5-24MFT* 4,450
LR24-MFT US LRX24-MFT + # LR100 RC1 ❑ ❑ ❑ *New linkage required.
LR24-MFT/200 US* LRX24-MFT + # LR100 RC3 ❑ ❑ ❑
NON FAIL-SAFE – 24 VAC NON FAIL-SAFE – 24 VAC

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


LR24-MFT/300 US LRX24-MFT + # LR100 RC3 ❑ ❑ ❑
LR24-SR/200 US* LRX24-SR + # LR030 RC3 002 Torque Torque
DISCONTINUED MODEL REPLACEMENT MODEL
LR24-SR/300 US LRX24-SR + # LR030 RC3 002 (in-lbs) (in-lbs)
LR24-SR-1 US LRB24-SR MAR100B 1,500 SY4-110* 3,559
LR24-SR-1/200 US* LRX24-SR + # LR030 RC3 002 MAR160B 2,000 SY4-110* 3,560
LR24-SR-1/300 US LRX24-SR + # LR030 RC3 002 MAR100BP 1,800 SY4-120MFT* 3,560

All prices are in US Dollars (USD)


LR24-SR-1-2.0 US LRB24-SR MAR160-BP 2,500 SY4-120MFT* 3,560
LR24-SR-1-2.0/200 US* LRX24-SR + # LR030 RC3 002 MAR250-30 5,000 SY5-110* 4,450
LR24-SR-1-2.0/300 US LRX24-SR + # LR030 RC3 002 MAR250-30P 5,000 SY6-110* 6,450
LR24-SR-2.0 US LRB24-SR SY6-120MFT* 6,450
LR24-SR-2.0/200 US* LRX24-SR + # LR030 RC3 002 MAR800-30 10,000 SY7-110* 9,790
LR24-SR-2.0/300 US LRX24-SR + # LR030 RC3 002 MAR800-30P 10,000 SY8-110 * 13,350
LV24 US CCV with LR...or TR...or Zonetight with CQ SY8-120MFT* 13,350
LV24/200 US* CCV with LR...or TR...or Zonetight with CQ MAR1600-70 21,000 SY10-110* 22,250
LV24/300 US CCV with LR...or TR...or Zonetight with CQ MAR1600-70P 21,000 SY10-120MFT* 22,250
LV24-1 US CCV with LR...or TR...or Zonetight with CQ MAR4000-70 48,000 SY12-110* 31,150
LV24-1/200 US* CCV with LR...or TR...or Zonetight with CQ MAR4000-70P 48,000 SY12-120MFT* 31,150
LV24-1/300 US CCV with LR...or TR...or Zonetight with CQ *New linkage required.

LV24-3 US CCV with LR...or TR...or Zonetight with CQ


NON FAIL-SAFE – SY ACTUATORS NON FAIL-SAFE – 24-240 VAC
LV24-3-1 US CCV with LR...or TR...or Zonetight with CQ
DISCONTINUED REPLACEMENT
LV24-SR US CCV with LR...or TR...or Zonetight with CQ Torque (in-lbs) Torque (in-lbs)
MODEL MODEL
LV24-SR/200 US* CCV with LR...or TR...or Zonetight with CQ
SY2-110* 800 PRBUP-3-T 1,400
LV24-SR/300 US CCV with LR...or TR...or Zonetight with CQ
SY3-110* 1,335 PRBUP-3-T 1,400
LV24-SR-1 US CCV with LR...or TR...or Zonetight with CQ
SY2-120MFT* 800 PRBUP-MFT-T 1,400
LV24-SR-1/200 US* CCV with LR...or TR...or Zonetight with CQ
SY3-120MFT* 1,335 PRBUP-MFT-T 1,400
LV24-SR-1/300 US CCV with LR...or TR...or Zonetight with CQ
SY2-24* 800 PRBUP-3-T 1,400
LV24-SR-1-2.0 US CCV with LR...or TR...or Zonetight with CQ
SY2-24MFT* 1,335 PRBUP-MFT-T 1,400
LV24-SR-1-2.0/200 US* CCV with LR...or TR...or Zonetight with CQ
SY3-24* 800 PRBUP-3-T 1,400
LV24-SR-1-2.0/300 US CCV with LR...or TR...or Zonetight with CQ
SY3-24MFT* 1,335 PRBUP-MFT-T 1,400
❑ Placeholder for custom options.
*These models had a 2m/6’ long cable and the replacement is a 3m/10’ long cable. *New linkage required.
CV must be known for proper replacement.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

21-2
Retrofit and Replacement, Zone Valves
Discontinued Belimo Products

ZONE VALVES*
Close-off Close-off
DISCONTINUED MODEL Size Cv Rating REPLACEMENT MODEL Size Cv Rating
(psi) (psi)
ZONE215N-10+ZONE24NO 1 75
Z214T+SEF24 NO ½” 2.3 43.5 ½”
ZONE215N-25+ZONE24NO 2.5 50
Z215T+SEF24 NO ½” 3.7 30 ZONE215N-35+ZONE24NO ½” 3.5 30
ZONE220N-35+ZONE24NO 3.5
Z220T+SEF24 NO ¾” 3.7 30 ¾” 30
ZONE220N-50+ZONE24NO 5
ZONE215N-10+ZONE120NO 1
Z214T+SEF120 NO ½” 2.3 43.5 ½” 75
ZONE215N-25+ZONE120NO 2.5
Z215T+SEF120 NO ½” 3.7 30 ZONE215N-35+ZONE120NO ½” 3.5 30
ZONE220N-35+ZONE120NO 3.5 30
Z220T+SEF120 NO ¾” 3.7 30 ¾”
ZONE220N-50+ZONE120NO 5 25
ZONE215N-10+ZONE24NC 1 75
Z214T+SEF24 NC ½” 2.3 43.5 ½”
ZONE215N-25+ZONE24NC 2.5 50
Z215T+SEF24 NC ½” 3.7 30 ZONE215N-35+ZONE24NC ½” 3.5 30
ZONE220N-35+ZONE24NC 3.5 30
Z220T+SEF24 NC ¾” 3.7 30 ¾”
ZONE220N-50+ZONE24NC 5 25
ZONE215N-10+ZONE120NC 1 75
Z214T+SEF120 NC ½” 2.3 43.5 ½”
ZONE215N-25+ZONE120NC 2.5 50
Z215T+SEF120 NC ½” 3.7 30 ZONE215N-35+ZONE120NC ½” 3.5 30
ZONE220N-35+ZONE120NC 3.5 30
Z220T+SEF120 NC ¾” 3.7 30 ¾”
ZONE220N-50+ZONE120NC 5 25
ZONE215N-10+ZONE24NC 1 75
Z214T+SEF24 NC ½” 2.3 43.5 ½”
ZONE215N-25+ZONE24NC 2.5 50
Z215T+SEF24 NC ½” 3.7 30 ZONE215N-35+ZONE24NC ½” 3.5 30
ZONE220N-35+ZONE24NC 3.5 30
Z220T+SEF24 NC ¾” 3.7 30 ¾”
ZONE220N-50+ZONE24NC 5 25
ZONE215N-10+ZONE120NC 1 75
Z214T+SEF120 NC ½” 2.3 43.5 ½”
ZONE215N-25+ZONE120NC 2.5 50
Z215T+SEF120 NC ½” 3.7 30 ZONE215N-35+ZONE120NC ½” 3.5 30
ZONE220N-35+ZONE120NC 3.5 30
Z220T+SEF120 NC ¾” 3.7 30 ¾”
ZONE220N-50+ZONE120NC 5 25
ZONE315N-10+ZONE24NC 1 75
Z315T+SEF24 NC ½” 5 30 ZONE315N-25+ZONE24NC ½” 2.5 50
ZONE315N-35+ZONE24NC 3.5 30
ZONE315N-10+ZONE120NC 1 75

RETROFIT SOLUTIONS
Z315T+SEF120 NC ½” 5 30 ZONE315N-25+ZONE120NC ½” 2.5 50
ZONE315N-35+ZONE120NC 3.5 30
ZONE320N-35+ZONE24NC 3.5 30
Z320T+SEF24 NC ¾” 5.4 30 ¾”
ZONE320N-50+ZONE24NC 5 25
ZONE320N-35+ZONE120NC 3.5 30
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

Z320T+SEF120 NC ¾” 5.4 30 ¾”
ZONE320N-50+ZONE120NC 5 25
ZONE215S-10+ZONE24NC 1 75
Z814T+SEF24 NO ½” 2.3 43.5 ½”
ZONE215S-25+ZONE24NC 2.5 50
Z815T+SEF24 NO ½” 3.7 30 ZONE215S-35+ZONE24NO ½” 3.5 30
ZONE220S-35+ZONE24NO 3.5 30
All prices are in US Dollars (USD)

Z820T+SEF24 NO ¾” 3.7 30 ¾”
ZONE220S-50+ZONE24NO 5 25
ZONE215S-10+ZONE120NO 1 75
Z814T+SEF120 NO ½” 2.3 43.5 ½”
ZONE215S-25+ZONE120NO 2.5 50
Z815T+SEF120 NO ½” 3.7 30 ZONE215S-35+ZONE120NO ½” 3.5 30
ZONE220S-35+ZONE120NO 3.5 30
Z820T+SEF120 NO ¾” 3.7 30 ¾”
ZONE220S-50+ZONE120NO 5 25
ZONE215S-10+ZONE24NC 1 75
Z814T+SEF24 NC ½” 2.3 43.5 ½”
ZONE215S-25+ZONE24NC 2.5 50
Z815T+SEF24 NC ½” 3.7 30 ZONE215S-35+ZONE24NC ½” 3.5 30
ZONE220S-35+ZONE24NC 3.5 30
Z820T+SEF24 NC ¾” 3.7 30 ¾”
ZONE220S-50+ZONE24NC 5 25
ZONE215S-10+ZONE120NC 1 75
Z814T+SEF120 NC ½” 2.3 43.5 ½”
ZONE215S-25+ZONE120NC 2.5 50
Z815T+SEF120 NC ½” 3.7 30 ZONE215S-35+ZONE120NC ½” 3.5 30
ZONE220S-35+ZONE120NC 3.5 30
Z820T+SEF120 NC ¾” 3.7 30 ¾”
ZONE220S-50+ZONE120NC 5 25
ZONE315S-10+ZONE24NC 1 75
Z915T+SEF24 NC ½” 5 30 ZONE315S-25+ZONE24NC ½” 2.5 50
ZONE315S-35+ZONE24NC 3.5 30
ZONE315S-10+ZONE120NC 1 75
Z915T+SEF120 NC ½” 5 30 ZONE315S-25+ZONE120NC ½” 2.5 50
ZONE315S-35+ZONE120NC 3.5 30
ZONE320S-35+ZONE24NC 3.5 30
Z920T+SEF24 NC ¾” 5.4 30 ¾”
ZONE320S-50+ZONE24NC 5 25
ZONE320S-35+ZONE120NC 3.5 30
Z920T+SEF120 NC ¾” 5.4 30 ¾”
ZONE320S-50+ZONE120NC 5 25
*The recommended replacements must be considered depending on the Cv rating and Close-off requirement involving your application.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

21-3
Honeywell to Belimo
Fire and Smoke Actuator Replacement Cross Reference

Fire and Smoke Actuator Replacement Solutions


DISCLAIMER:
For Fire and Smoke Actuators use the UL555S test to select the correct actuator for your application - do not match actuator to actuator.
Different methods are employed by different manufacturers to achieve the fire spring-closed function. For example, Pottorff damper with the MA220
actuator is a single spring. To replace the discontinued MA220, the fusible link must be removed and a thermal sensor installed.
Ruskin dampers use an external spring and a thermal sensor, so removal of the old MA220 and external spring and replacement with Belimo is all that
is required.
Note: NFPA 80 and NFPA 105 require that dampers be repaired as soon as possible. In most jurisdictions, this is a normal repair. In some areas, a
permit and 3rd party inspection may be required. In all cases, a log of periodic testing and any repairs must be maintained within the facility. Repair
of any fire and smoke damper is required by codes. A permit and retest may be required if the replacement is not an ordinary repair.
When any fire alarm wiring is touched, or any structural changes are made, the fire department or building official must be consulted, and a permit
plus inspection is required.
Visit http://www.belimo.us/firesmoke for detailed instructions for each damper manufacturer.

Model Belimo Replacement Model


NOTES HONEYWELL BELIMO Fail-Safe Control Signal Power Supply Torque (in-lbs)
ML4105A1000 FSLF120 US Yes On/Off 120 VAC 30
ML4105B1009 FSLF120 US Yes On/Off 120 VAC 30
ML4105C1008 FSLF230 US Yes On/Off 230 VAC 30
ML4105D1007 FSLF230 US Yes On/Off 230 VAC 30
ML4115A1009 FSLF120 US Yes On/Off 120 VAC 30
ML4115A1017 FSLF120 US Yes On/Off 120 VAC 30
ML4115B1008 FSLF120 US Yes On/Off 120 VAC 30
ML4115B1016 FSLF120 US Yes On/Off 120 VAC 30
ML4115C1007 FSLF230 US Yes On/Off 230 VAC 30
ML4115C1015 FSLF230 US Yes On/Off 230 VAC 30
ML4115D FSLF230 US Yes On/Off 230 VAC 30
ML4115D1006 FSLF230 US Yes On/Off 230 VAC 30
RETROFIT SOLUTIONS

ML4115H FSLF120 US Yes On/Off 120 VAC 30


ML4115H1002 FSLF120 US Yes On/Off 120 VAC 30
Go to www.belimo.us/firesmoke for ML4115J FSLF120 US Yes On/Off 120 VAC 30
Installation Instructions. ML4202 FSLF120 US Yes On/Off 120 VAC 30

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


ML4202F1000 FSLF120 US Yes On/Off 120 VAC 30
FSTF may be used on dampers
ML4302F1008 FSLF120 US Yes On/Off 120 VAC 30
<1.5 sq.ft.
ML4702 FSLF120 US Yes On/Off 120 VAC 30
Use FSLF for dampers < 4 sq.ft. ML4802 FSLF230 US Yes On/Off 230 VAC 30
Use FSNF for dampers between 4 sq.ft. ML8105A1006 FSLF24 US Yes On/Off 24 VAC 30
and 12 sq.ft. ML8105B1005 FSLF24 US Yes On/Off 24 VAC 30

All prices are in US Dollars (USD)


Use FSAF*A for dampers up to 16 sq.ft. ML8115A1005 FSLF24 US Yes On/Off 24 VAC 30
ML8115A1013 FSLF24 US Yes On/Off 24 VAC 30
Multi-section dampers should be ML8115B1004 FSLF24 US Yes On/Off 24 VAC 30
investigated for number of actuators
ML8115B1012 FSLF24 US Yes On/Off 24 VAC 30
required.
ML8115H FSLF24 US Yes On/Off 24 VAC 30
See data sheets for linkages. FSLF is direct ML8115J FSLF24 US Yes On/Off 24 VAC 30
couple only.
ML8202 FSLF24 US Yes On/Off 24 VAC 30
ML8302 FSLF24 US Yes On/Off 24 VAC 30
MS4104F1010 FSLF120 US Yes On/Off 120 VAC 30
MS4104F1010 FSLF120 US Yes On/Off 120 VAC 30
MS4104F1210 FSLF120-S US Yes On/Off 120 VAC 30
MS4109F1010 FSNF120 US Yes On/Off 120 VAC 70
MS4109F1210 FSNF120-S US Yes On/Off 120 VAC 70
MS4120F1006 FSAF120A Yes On/Off 120 VAC 180
MS4120F1204 FSAF120A-S Yes On/Off 120 VAC 180
MS4209F FSNF120 US Yes On/Off 120 VAC 70
MS4209F1007 FSNF120 US Yes On/Off 120 VAC 70
MS4309F FSNF120 US Yes On/Off 120 VAC 70
MS4309F1005 FSNF120 US Yes On/Off 120 VAC 70
MS4604F1010 FSLF230 US Yes On/Off 230 VAC 30
MS4604F1210 FSLF230-S US Yes On/Off 230 VAC 30

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

21-4
Honeywell/Ruskin to Belimo
Fire and Smoke Actuator Replacement Cross Reference

Model Belimo Replacement Model


NOTES HONEYWELL BELIMO Fail-Safe Control Signal Power Supply Torque (in-lbs)
MS4609F1010 FSNF230 US Yes On/Off 230 VAC 70
MS4609F1210 FSNF230-S US Yes On/Off 230 VAC 70
MS4620F1005 FSAF230A Yes On/Off 230 VAC 180
MS4620F1203 FSAF230A-S Yes On/Off 230 VAC 180
Go to www.belimo.us/firesmoke for MS4709F FSNF230 US Yes On/Off 230 VAC 70
Installation Instructions. MS4709F1014 FSNF230 US Yes On/Off 230 VAC 70
MS4809F FSNF230 US Yes On/Off 230 VAC 70
FSTF may be used on dampers
MS4809F1012 FSNF230 US Yes On/Off 230 VAC 70
<1.5 sq.ft.
MS7520A2015 FSAFB24-SR Yes 2-10V, 4-20mA 24 VAC 180
Use FSLF for dampers < 4 sq.ft. MS8104F1010 FSLF24 US Yes On/Off 24 VAC 30
Use FSNF for dampers between 4 sq.ft. MS8104F1210 FSLF24 US Yes On/Off 24 VAC 30
and 12 sq.ft. MS8109F1010 FSNF24 US Yes On/Off 24 VAC 70
Use FSAF*A for dampers up to 16 sq.ft. MS8109F1210 FSNF24-S US Yes On/Off 24 VAC 70
MS8120F1002 FSAF24A Yes On/Off 24 VAC 180
Multi-section dampers should be MS8120F1200 FSAF24A-S Yes On/Off 24 VAC 180
investigated for number of actuators
MS8209F FSNF24 US Yes On/Off 24 VAC 70
required.
MS8209F1003 FSNF24 US Yes On/Off 24 VAC 70
See data sheets for linkages. FSLF is MS8309F FSNF24 US Yes On/Off 24 VAC 70
direct couple only. MS8309F1001 FSNF24 US Yes On/Off 24 VAC 70
S20230-F FSAF230A Yes On/Off 230 VAC 180
S20230-F-SW2 FSAF230A-S Yes On/Off 230 VAC 180
S2024-F FSAF24A Yes On/Off 24 VAC 180
S2024-F-SW2 FSAF24A-S Yes On/Off 24 VAC 180
32003532-002 Use Belimo “-S”
Auxiliary switch packages N/A N/A N/A N/A
Aux Switch Package models

Call Belimo for assistance. Digital photographs of damper and old motor mounting will be needed. Generally replaced by FSLF for direct coupled and FSNF if
ECM
linkages are needed. Motors were non-spring. Damper OEM external spring must be removed or disabled.
Honeywell, 5800 EMB 2X and other models can easily be replaced if damper shaft is present. Call Belimo for more information. Refer to Multiproducts on page
Prefco
21-6.
Modulating Various models of Honeywell and other modulating can be replaced. FSAFB24-SR and FSAFB24-SR-S are available.

RETROFIT SOLUTIONS
Retrofit of pneumatic actuators with Belimo electronic ones will usually require some re-control also. Depending on age and manufacturer, the fusible links, fusible
Pneumatic
air valve, smoke control relays, or other components may have to be replaced or upgraded.
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

Model Belimo Replacement Model


NOTES RUSKIN BELIMO Fail-Safe Control Signal Power Supply Torque (in-lbs)
H-2000A/3 Low FSLF120 US Yes On/Off 120 VAC 30
H-2000A/6 Medium FSNF120 US Yes On/Off 120 VAC 70
All prices are in US Dollars (USD)

H-2000A/8 High FSNF120 US Yes On/Off 120 VAC 70


H-2000B/3 Low FSLF120 US Yes On/Off 120 VAC 30
H-2000B/6 Medium FSNF120 US Yes On/Off 120 VAC 70
H-2000B/8 High FSNF120 US Yes On/Off 120 VAC 70
H-2024A/3 Low FSLF24 US Yes On/Off 24 VAC 30
H-2024A/6 Medium FSNF24 US Yes On/Off 24 VAC 70
H-2024A/8 High FSNF24 US Yes On/Off 24 VAC 70
The Ruskin/HW motors vary irregularly H-2024B/3 Low FSLF24 US Yes On/Off 24 VAC 30
in torque. It is best to use damper size H-2024B/6 Medium FSNF24 US Yes On/Off 24 VAC 70
to select. H-2024B/8 High FSNF24 US Yes On/Off 24 VAC 70
< 4 sq.ft. use FSLF Series. H-2230A/3 Low FSLF230 US Yes On/Off 230 VAC 30
> 4 sq.ft. use FSNF Series. H-2230A/6 Medium FSNF230 US Yes On/Off 230 VAC 70
H-2230A/8 High FSNF230 US Yes On/Off 230 VAC 70
H-2230B/3 Low FSLF230 US Yes On/Off 230 VAC 30
H-2230B/6 Medium FSNF230 US Yes On/Off 230 VAC 70
H-2230B/8 High FSNF230 US Yes On/Off 230 VAC 70
RH-24 FSNF24 US Yes On/Off 24 VAC 70
RH-24-S FSNF24-S US Yes On/Off 24 VAC 70
RH-120 FSNF120 US Yes On/Off 120 VAC 70
RH-120-S FSNF120-S US Yes On/Off 120 VAC 70
RH-24-MOD FSAFB24-SR Yes 2-10 VDC 24 VAC 180

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

21-5
Ruskin/Multiproducts to Belimo
Fire and Smoke Actuator Replacement Cross Reference

Model Belimo Replacement Model


NOTES- PHILLIPS P150 RUSKIN BELIMO Fail-Safe Power Supply Torque
Shaft spring must be disabled. See Ruskin with Phillips P150 at
www.belimo.us/firesmoke
Linkages and switch model available. Some used with Negator springs;
if so, call for assistance.
Phillips P150 See notes at left Yes On/Off See notes at left
Use FSNF for dampers up to 12 sq.ft.
Use FSNF*A for dampers up to 16 sq.ft

Model Belimo Replacement Model


Control Torque
NOTES MULTIPRODUCTS BELIMO Fail-Safe Power Supply
Signal (in-lbs)
Greenheck. Typically these were linkaged using a crank arm on the square
motor shaft and the spring was on the round shaft. Remove all linkage 2430 No On/Off 120 VAC 30
parts and direct couple to damper shaft.
Air Balance. Square shaft inserted into damper sleeve with special
crankarm. If a smoke damper, replacement may be possible and requires a
2553A No On/Off 120 VAC 30
new shaft and other linkage parts. If a combination fire and smoke damper,
it is possible Belimo cannot be used. Most dampers must be replaced.
Greenheck. Typically these were linkaged using a crank arm on the square
motor shaft and the spring was on the round shaft. Remove all linkage 2585, 2586 No On/Off 120 VAC 30
parts and direct couple to damper shaft.
Safe-Air / Imperial. Typically linkaged. There was an internal spring and
2659 No On/Off 120 VAC 30
fusible link for the fire function.
Air Balance. FSLF < 3 sq.ft.; FSNF 3 to 8 sq.ft. Remove old motor and
external spring. Belimo mounts on shaft without linkages. Use old motor as 2724 No On/Off 120 VAC 30
a mounting platform for anti-rotation strap.
Ruskin. FSLF120/MP Kit available from Ruskin Reps. See instructions for
negator spring removal. Some dampers will need fusible link 2781 or 1161B No On/Off 24/120 VAC 30
replaced and thermal sensor installed.
Ruskin. 10 in-lb. "A" model = CW rotation; plain = CCW. Check voltage. FSLF
2814A-SQ No On/Off 120 VAC 30
replaces both in most cases. Use FSTF when linkages necessary.
RETROFIT SOLUTIONS

Depends on specific geometry of installation. All FSTF & FSNF parts can be
used. Inside clamp mounting or a shaft extension required. Inside clamp 2920 FSLF120 US if No On/Off 120 VAC 30
mounting or a shaft extension may be required. direct coupled.
Greenheck.Typically these were linkaged using a crank arm on the square See notes 1, 2,

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


shaft and the spring was on the round shaft. Remove all linkage parts and 2985, 2986 3 below No On/Off 120 VAC 30
direct couple to damper shaft. (Model difference is CW vs. CCW.)
Greenheck. Some were direct coupled to the damper shaft with an external
spring. Some were linkaged using a crank arm on the square motor shaft
3158, 3159 No On/Off 120 VAC 30
and the spring was on the round shaft. Remove all linkage parts and direct
couple to damper shaft. (Model difference is CW vs. CCW.)

All prices are in US Dollars (USD)


Prefco. Outside the duct, 1 is top mount, power open. 10 is bottom mount,
power closed. Review of linkages, springs, fusible link or McCabeLink©
5800EMB1,10 No On/Off 120 VAC 30
must be performed. Power closed typically used in smoke control systems
so switches may be needed.
Prefco. Review of linkages, springs, fusible link or McCabeLink© must be 5800EMB2XPC,
No On/Off 120 VAC 30
performed. PO, 5800EMB8, 9
Prefco. Inside the duct, 5 is top mount, power open. 7 is bottom mount,
power closed. Review of linkages, springs, fusible link or McCabeLink©
5800EMB5, 7 No On/Off 120 VAC 30
must be performed. Power closed typically used in smoke control systems
so switches may be needed.

6247 No On/Off 120 VAC 30


Nailor. Remove linkage parts and mount to damper shaft. FSLF for dampers
< 4 sq.ft. and FSNF for dameprs > 4 sq.ft.
MZRHM No On/Off 120 VAC 30

Greenheck and others. Typically these were linkaged using a crank arm on
the square motor shaft and the spring was on the round shaft. Remove all TB2001, TSB2000 No On/Off 120 VAC 30
linkage parts and direct couple to damper shaft.
1. In general, use FSLF If a shaft is available for direct coupling and damper is < 4 sq.ft. Use FSNF and ZG-AF US or other linkage if linkage is necessary and damper is > 4 sq.ft.. Use
FSTF if damper < 1.5 sq.ft. Linkage or direct couple.

2. Note that in almost all cases the old linkage, spring, and motor can be removed and mounting Belimo to the shaft is the accepted procedure to make the assembly conform to modern
fire & smoke dampers.
3. Investigation of each application is necessary. Check voltage and breakers. In all cases disconnect external motor spring without compromising fusible link and internal spring ability
to close the blades. These are quite old and changes may have been made by others over the years. Check fusible links or McCabe© Link. Verify damper functions after replacement by
testing damper open and spring closed.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

21-6
Siemens/Siebe to Belimo
Fire and Smoke Actuator Replacement Cross Reference

Model Belimo Replacement Model


Control Torque
NOTES SIEMENS* BELIMO Fail-Safe Power Supply
Signal (in-lbs)
GGD121.1U FSAF24A Yes On/Off 24 VAC 180
GGD121.3U FSAF24A Yes On/Off 24 VAC 180
GGD221.1U FSAF120A Yes On/Off 120 VAC 180
GGD221.3U FSAF120A Yes On/Off 120 VAC 180
GGD321.1U FSAF230A Yes On/Off 230 VAC 180
GND12x.1x FSLF24 US Yes On/Off 24 VAC 30
GND22x.1x FSLF120 US Yes On/Off 120 VAC 30
GND32x.1x FSLF230 US Yes On/Off 230 VAC 30
This is a 165ºF thermal sensor.
ASK79.165 BAE165 US
Call for information.

* While drive torque of Siemens is 142 in-lbs, spring torque is 110 in-lbs. Belimo has passed UL555S at 12 sq.ft.

Model Belimo Replacement Model


Control
NOTES SIEBE BELIMO Fail-Safe Power Supply Damper Size
Signal
MA220 FSLF120 US Yes On/Off 120 VAC
MA221 FSLF230 US Yes On/Off 240 VAC
MA223 FSLF24 US Yes On/Off 24 VAC
Where linkages are needed, use FSNF. Timing is a function
MA230 FSNF120 US Yes On/Off 120 VAC
of damper spring. For <4 sq. ft. dampers
MA231 FSNF230 US Yes On/Off 240 VAC
use FSLF Series
When replacing the actuator, remove the old spring from MA233 FSNF24 US Yes On/Off 24 VAC
the damper. MA240 Call Belimo Yes On/Off 120 VAC For >4 sq. ft.
MA250 FSNF120 US Yes On/Off 120 VAC use FSNF Series
If the damper has one spring, add a new electric thermal
MA251 FSNF230 US Yes On/Off 230 VAC
sensor. (Belimo BAE 165)
MA253 FSNF24 US Yes On/Off 24 VAC
A -500 part number indicates an auxiliary switch. Replace MA-318 FSNF24 US Yes On/Off 24 VAC
with a Belimo “-S” version. MA-318-500 FSNF24 -S US Yes On/Off 24 VAC
MA-418 FSNF120 US Yes On/Off 120 VAC
<4 sq.ft use FSLF
MA-418-500 FSNF120-S US Yes On/Off 120 VAC
>4.sq.ft. use FSNF

RETROFIT SOLUTIONS
Qualifications for Belimo in Replacing Defective Competitive Actuators
Belimo is UL 555S Listed with all damper manufacturers. In addition, all Belimo Fire and Smoke actuators have passed UL 2043 in accordance to requirements of the NEC 300.22 (c) and the
IMC 602 for use in plenums. The basic UL listings are either UL 873 or UL 60730 which has supplanted UL 873. UL 873 has been grandfathered.
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

Infrequently, the fire alarm standard, UL 864, and list of qualified smoke control systems, UUKL, are specified. UL has clearly stated that it will not investigate dampers or actuators in
accordance with these standards and that UL 555 (fire) and UL 555S (smoke) are the only correct standards.
UL has stated that while field replacement of actuators is allowed, the local AHJ is in charge; UL does not regulate field repairs. NFPA 80 (fire) & NFPA 105 (smoke) are the standards
referenced by the IBC which regulate replacement and repair.
All prices are in US Dollars (USD)

Visit www.belimo.us/firesmoke for detailed instructions for each damper manufacturer.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

21-7
How to Select a Globe Valve Retrofit Solution

How to Select a Globe Valve Retrofit Solution


Follow the four steps listed below when ordering a globe valve retrofit kit for either UGLK or GVL series linkages.
Example: Siemens 658 series, 1¼” valve, needing 200 psi close-off pressure and Fail-Safe actuation.

1 Based on the Valve Number, Configuration and Size, select the proper linkage or linkages for your valve.
Some valves will have more than one linkage offered, use the actuator or combination pages to determine the appropriate linkage
for a given application. In this example there is a UGLK1214, UGLK1350 and a UGVL series linkage available.

2 Use the selection guide and your close-off pressure requirement to select the correct actuator series for your application.
Looking at the UGLK1350 there are no fail-safe actuators that will achieve 200 psi close-off for 1¼" valve. Looking at the
UGLK1214 or UGVL, the AF or SVK Series actuator will provide over 200 psi close-off for the 1¼” valve.

3 Use the actuator listings to make your final actuator selection.

4 HOW TO ORDER: Option One: Option Two:


Item 1 1pc UGLK1214 Item 1 1pc UGVL + SVKB24-MFT
Item 2 1pc AFB24-MFT

Select linkage solution


based on the Valve Siemens\Landis\Powers
Number, Configuration, 658 Series Valves
1 and Size; select the Linkage/Actuator Selection Guide
proper Linkage Solution
Belimo
for your valve. Valve Body Model
Valve
Size Fail-safe Close-Off psi Actuator Series
Belimo
Configuration Linkage

658 Series 2-way 1¼” No 78 LM UGLK1350


Example: Siemens Series #658, 156 NM UGLK1350
2-Way, 1¼” valve to be retrofitted. 236 SV UGVL
RETROFIT SOLUTIONS

Choose correct kit UGLK1214 250 AM UGLK1214


or UGVL. Yes 61 LF UGLK1350
156 NF UGLK1214
236 SVK UGVL

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


Verify close-off is suitable 250 AF UGLK1214
for application.
Looking at the UGLK or
2 UGVL, the AF and SVK Series
actuator will provide 200 psi BASIC PRODUCTS

All prices are in US Dollars (USD)


close-off for the 1¼” valve.
Running Time(s)
Power Auxiliary
Control Input Feedback VA Rating
Supply Switch
Model

AFB24 On/Off - 24 VAC/DC <75 seconds 20 secs 7.5 -
Select actuator based on AFB24-S On/Off - 24 VAC/DC <75 seconds 20 secs 7.5 Built-In

needed control type. AFBUP On/Off - 24-240 VAC <75 seconds 20 secs 8.5 -

Decide between AFB24, AFBUP-S On/Off - 24-240 VAC <75 seconds 20 secs 8.5 Built-In
AFB24-SR 2-10 VDC (4-20mA) 2-10 VDC 24 VAC/DC 95 seconds <20 secs 8.5 -
AFB24-MFT AFB24-SR-S 2-10 VDC (4-20mA) 2-10 VDC 24 VAC/DC 95 seconds <20 secs 8.5 Built-In
3 AFB24-PC 0-10 V Phasecut 2-10 VDC 24 VAC/DC 150 seconds <20 secs 10 -
or SVKX24-3, AFB24-MFT 2-10 VDC (4-20mA) 2-10 VDC 24 VAC/DC 150 seconds <20 secs 10 -
AFB24-MFT-S 2-10 VDC (4-20mA) 2-10 VDC 24 VAC/DC 150 seconds <20 secs 10 Built-In
SVKB24-MFT. AFB24-MFT95 0 to 135 2-10 VDC 24 VAC/DC 150 seconds <20 secs 10 -
Consult actuator overview
section for full details.

Complete Ordering Example ACTUATOR PART # LVKX24-3 LVKB24-SR LVKB24-MFT SVKX24-3 SVKB24-SR SVKB24-MFT

Option One: Control type


On/Off,
Modulating Modulating/MFT
On/Off,
Modulating Modulating/MFT
4 Item 1: UGLK1214 Input signal / Feedback
Floating Point
- 2-10 VDC Variable
Floating Point
- 2-10 VDC Variable
Running time Motor 150 seconds 150 seconds Variable 150 seconds 150 seconds Variable
Item 2: AFB24-MFT Fail-Safe 35 seconds 35 seconds 35 seconds 35 seconds 35 seconds 35 seconds
Actuator travel 24mm 24mm 24mm 24mm 24mm 24mm
Actuator noise level <45 dB(A) <45 dB(A) <45 dB(A) <45 dB(A) <45 dB(A) <45 dB(A)
Complete Ordering Example GVL LINKAGES
Option Two: Universal Adjustable for
4 Item 1: UGVL +
UGVL
1/2” to 2”
$ $ $ $ $ $

SGVL Schnieder VB7..., VB9... $ $ $ $ $ $

SVKB24-MFT

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

21-8
Retrofit and Replacement, Siemens 599 MT/MZ
UGSL1200 Short-Stroke Valve Retrofit Kit for CM and TF Series Actuators

Application
The UGSL1200 retrofit kit is designed to easily attach to the valve bonnet on
select Siemens 599 MT/MZ short-stroke valves utilizing Belimo CM and TF*
series actuators. See accessories in Technical Data table for all available
competitor collars.
The unique coupler design allows the UGSL1200 to be mounted on any ½” to
1¼” two-way or three-way valves. In addition, the linkage is suitable for both
normally open and normally closed valves.

Default/Configuration
The default set up for this linkage is for usage with the CM actuator. Included in
the kit is an extension piece for TF actuators. Hardware is supplied to attach the
shaft extension and anti-rotation screws to both a CM or TF actuator.

Operation
The UGSL1200 linkage provides 6 mm of downward stroke with 95° CW rotation
on the actuator. This allows the valve to extend fully open or closed based on
signal. The slot located on the housing provides indication when the maximum
stroke has been reached. For troubleshooting when using a CM actuator, the
operator may use the manual override feature to rotate the linkage up or down.
List Price: $108 When using the TF, refer to electronic override instructions according to actuator
model.
Technical Data UGSL1200
Housing aluminum Note: Linkage cannot be used on 1½” normally closed valves.
Materials: *TFL actuators required for on/off applications.
Coupling nut brass ** CMB24-SR-R for 2V stem down, CMB24-SR-L for 2V stem up.
Shafts stainless steel
Base plate aluminum TF Dimensions (Inches [mm])
Upper plate stainless steel

D315
Cams nylon 6/6 with MDS
Stroke 6 mm in CW direction
Max out force 67 lbf [300 N]
Mounting position 360° mountable as shown
Ambient temperature -22°F to +122°F [-30°C to +50°C]
Storage temperature -40°F to +176°F [-40°C to +80°C]

RETROFIT SOLUTIONS
Servicing chilled or hot water
max steam inlet 15 psi
Weight 1.25 lbs [0.57 kg]
Accessories UGSL-ADPT Collar for:
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

• Danfoss • HW Braukman
• Oventrop • Siemens
• Cazzaniga • JCI
• Spartan • Taco
All prices are in US Dollars (USD)

Mounting Configurations

CM Dimensions (Inches [mm])


360°

D316
2.4” [60.3]

360° 6.3” [159.8]

TF Actuator*
2.8” [72]
3.7” [95.2]

1.5” [37.9]

2.4” [60.3]

CM Actuator**

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

21-9
Dimensions of Globe Valve Retrofit Solutions

MAXIMUM DIMENSIONS – UGLK Linkages with Rotary Actuators

Linkages Taking 1 Actuator Linkages Taking 2 Actuators


B C D

B C D

H1

H2

UGLK1150 and UGLK1550 MAXIMUM DIMENSIONS


If the required spring return direction is not known, a UGLK
linkage and spring return actuator may be selected. The rotary
B C D actuators can be turned over on the linkage and produce a
spring return function in either direction.
Linkages Taking 1 Actuator
H1
A 7”-14” [356] D 5” [127]
A B 3” [76] H1 9.5” [241]
C 9” [229] H2 9.5”
RETROFIT SOLUTIONS

H2

Linkages Taking 2 Actuators


A 19” [483] D 5” [127]

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


B 3” [76]
C 9” [229]

UGLK1150 and UGLK1550


A 6.5” [165] D 4.0” [102]

All prices are in US Dollars (USD)


B 1.5” [33] H1 4.0” [102]
C 5.0” [127] H2 3.5" [89]

MAXIMUM DIMENSIONS – GVL Linkages with New Generation Linear Series Actuators

FGVL with EV, RV Actuators FGVL with AVK Actuators

9.2” [234] 2.78” 2.78” 2.78” 2.78”


10.25” [260] [71] [71]
[71] [71]

16.73”
[425] 16.73”
[425]
14” 14”
[356] [356]

5” [127] 5” [127]

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

21-10
Dimensions of Globe Valve Retrofit Solutions

MAXIMUM DIMENSIONS – GVL Linkages with New Generation Linear Series Actuators

Self Adapting Stroke


The “V” Series actuators, which are used with the UGVL, SGVL, FGVL, and WGVL retrofit kits, are stroke adapting actuators. In modulating
applications, the actuator will recognize the stroke length requirement and automatically adjust the control signal for maximum resolution.

UGVL with LV, SV Dimensions (Inches [mm]) UGVL with LVK, SVK Dimensions (Inches [mm])
4.4” [113] 4.4” [113]

8.5” [215] 9.6” [244]


1.8” [45] 1.8” [45] 4.4” [113]
4.4” [113]

12.1” [307]
11.4” [290]

8.5” [217]
7.9” [200]

8.4” [207]
7.5” [190]

SGVL with LV, SV Dimensions (Inches [mm]) SGVL with LVK, SVK Dimensions (Inches [mm])

7.8” [199] 8.2” [209]


1.8” [45] 3.9” [98] 1.8” [45] 3.9” [98]

RETROFIT SOLUTIONS
5.9” [150]

6.7” [169]

6.6” [167]
6” [152]
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.
All prices are in US Dollars (USD)

WGVL with EV, RV Dimensions (Inches [mm]) WGVL with AVK Dimensions (Inches [mm])
9.2” [233] 10.3” [262]
2.1” [53] 5.5” [140] 2.1” [53] 5.5” [140]
12.22” [310]

12.22” [310]
10.9” [276]

10.9” [276]

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

21-11
UGVL, SGVL, FGVL, and WGVL Series Linkages with Non Fail-Safe Actuators
Retrofit Linkages for NPT and Flanged Globe Valves

Actuator/Linkage Specifications
Force (valve size)
LV 112 lbf [500N] (½” to ¾”)
SV 337 lbf [1500N] (1” to 2”)
EV 562 lbf [2500N] (2½” to 4”)
RV 1011 lbf [4500N] (4” to 6”)
Linkage Material aluminum and steel
Fits Valve Bonnet up to 1.7” [43.18 mm] UGVL
Diameter up to 2.7” [68.5 mm] FGVL
Position Indication adjustable inserts on linkage
Manual Override external push button
LV, SV 4 mm hex (wrench supplied)
EV, RV 5 mm hex (wrench supplied)
Direction of Rotation external switch
Dimensions
UGVL 7.5” to 11.4” x 7.8” x 4.5” All actuators
SGVL 6” x 7.8” x 3.9” have BDCM

FGVL 14” x 9.2” x 5.5”


WGVL 10” x 9.2” x 5.5”
Electrical Connection 3 ft., 18 GA plenum rated
24V cable, ½” conduit fitting
120V appliance cable
Overload Protection electronic throughout stroke
Auxiliary Switch(es) add on: 2 SPDT, 3A @ 250V
Housing NEMA 2/IP54, UL Enclosure
Type 2
Agency Listings cULus according to UL
60730-1A/-2-14, CAN/CSA
E60730-1:02, CE according
to 2004/108/EC and UGVL SGVL
2006/95/EC

ACTUATOR PART # LVB24-3 LVX120-3 LVB24-SR LVX24-MFT SVX24-3 SVX120-3 SVB24-SR SVX24-MFT
On/Off, On/Off, Modulating/ On/Off, On/Off, Modulating/
Control Type Modulating Modulating
Floating PointFloating Point MFT Floating Point Floating Point MFT
Input Signal / Feedback - - 2-10 VDC* Variable - - 2-10 VDC* Variable
90 seconds 90 seconds 90 seconds 90 seconds 90 seconds
RETROFIT SOLUTIONS

Running Time 90 seconds 90 seconds 90 seconds


(variable) (variable) (variable) (variable) (variable)
Actuator Travel 15 mm (0.60”) 15 mm (0.60”) 15 mm (0.60”) 15 mm (0.60”) 20 mm (0.75”) 20 mm (0.75”) 20 mm (0.75”) 20 mm (0.75”)
Actuator Noise Level 55 dB(A) 55 dB(A) 55 dB(A) 55 dB(A) 45 dB(A) 45 dB(A) 45 dB(A) 45 dB(A)
GVL LINKAGES

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


UGVL Universal adjustable for ½” to 2” $686 $719 $751 $825** $802 $834 $866 $943**
Schneider VB7000 (½” to 2”),
SGVL $634 $668 $698 $765** $714 $805 $783 $853**
VB9000 (½” to 1¼”)
 Variable with MFT.
* 4-20 mA with 500 Ω resistor ZG-R01

All prices are in US Dollars (USD)


**Prices do not reflect additional programming codes surcharge. See page 21-14 for linear actuator MFT codes.

FGVL WGVL

ACTUATOR PART # EVB24-3 EVB120-3 EVB24-SR EVB24-MFT RVB24-3 RVB24-MFT


On/Off, On/Off, On/Off,
Control Type Modulating Modulating/MFT Modulating/MFT
Floating Point Floating Point Floating Point
Input Signal / Feedback - - 2-10 VDC* 2-10 VDC* - 2-10 VDC*
Running Time 90 seconds 90 seconds 90 seconds 90 seconds (variable) 90 seconds 90 seconds (variable)
Actuator Travel 50 mm (2”) 50 mm (2”) 50 mm (2”) 50 mm (2”) 50 mm (2”) 50 mm (2”)
Actuator Noise Level 65 dB(A) 65 dB(A) 65 dB(A) 65 dB(A) 65 dB(A) 65 dB(A)
GVL LINKAGES
FGVL Flanged valves adjustable for 2½” to 6” $1,706 $1,803 $1,762 $1,775** $1,923 $2,006**
WGVL Warren Controls Type 20, 22, 30, 32 $981 $1,300 $1,036 $1,114** $1,100 $1,232**
* 4-20 mA with 500 Ω resistor ZG-R01
**Prices do not reflect additional programming codes surcharge. See page 21-14 for linear actuator MFT codes.
Note: All “B” versions available as customizable “X” versions. Please see www.belimo.us for details.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

21-12
UGVL, SGVL, FGVL, and WGVL Series Linkages with Electronic Fail-Safe Actuators
Retrofit Linkages for NPT and Flanged Globe Valves

Actuator/Linkage Specifications
Force (valve size)
LVK 112 lbf [500N] (½” to ¾”)
SVK 337 lbf [1500N] (1” to 2”)
AVK 450 lbf [2000N] (2½” to 4”)
Linkage Material aluminum and steel
Fits Valve Bonnet up to 1.7” [43.18 mm] UGVL
Diameter up to 2.7” [68.5 mm] FGVL
Position Indication adjustable inserts on linkage
Manual Override external push button
LV, SV 4 mm hex (wrench supplied)
AVK 5 mm hex (wrench supplied)
Fail Postion field selectable
Direction of Rotation external switch
Dimensions
UGVL 8” to 12” x 9.5” x 4.5” All actuators
have BDCM
SGVL 6.5” x 9.5” x 4.5”
FGVL 14” x 9.2” x 5.5”
WGVL 10” x 9.2” x 5.5”
Electrical Connection 3 ft., 18 GA plenum rated
24V cable, ½” conduit fitting
120V appliance cable
Overload Protection electronic throughout stroke
Auxiliary Switch(es) add on: 2 SPDT, 3A @ 250V
Housing NEMA 2/IP54, UL Enclosure
Type 2
Agency Listings cULus according to UL
60730-1A/-2-14, CAN/CSA
E60730-1:02, CE according
to 2004/108/EC and
UGVL SGVL
2006/95/EC

ACTUATOR PART # LVKX24-3 LVKX120-3 LVKB24-SR LVKB24-MFT SVKX24-3 SVKX120-3 SVKB24-SR SVKB24-MFT
On/Off, On/Off, Modulating/ On/Off, On/Off, Modulating/
Control Type Modulating Modulating
Floating Point Floating Point MFT Floating Point Floating Point MFT
Input Signal / Feedback - - 2-10 VDC* 2-10 VDC* - - 2-10 VDC* 2-10 VDC*

RETROFIT SOLUTIONS
Running Time 90 seconds 90 seconds 90 seconds 90 seconds 90 seconds 90 seconds
Motor 90 seconds 90 seconds
(variable) (variable) (variable) (variable) (variable) (variable)
Fail-Safe 35 seconds 35 seconds 35 seconds 35 seconds 35 seconds 35 seconds 35 seconds 35 seconds
Actuator Travel 15 mm (0.60”) 15 mm (0.60”) 15 mm (0.60”) 15 mm (0.60”) 20 mm (0.75”) 20 mm (0.75”) 20 mm (0.75”) 20 mm (0.75”)
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

Actuator Noise Level 55 dB(A) 55 dB(A) 55 dB(A) 55 dB(A) 45 dB(A) 45 dB(A) 45 dB(A) 45 dB(A)
GVL LINKAGES
UGVL Universal adjustable for ½” to 2” $998 $1,039 $1,056 $1,142** $1,121 $1,163 $1,180 $1,264**
Schneider VB7000 (½” to 2”),
SGVL $874 $914 $934 $1,045** $962 $1,001 $1,026 $1,103**
VB9000 (½” to 1¼”)
 Variable with MFT.
All prices are in US Dollars (USD)

* 4-20 mA with 500 Ω resistor ZG-R01


**Prices do not reflect additional programming codes surcharge. See page 21-14 for linear actuator MFT codes.

FGVL WGVL

ACTUATOR PART # AVKB24-3 AVKB120-3 AVKB24-MFT


On/Off, On/Off,
Control Type Modulating/MFT
Floating Point Floating Point
Input Signal / Feedback - - 2-10 VDC*
Running Time Motor 90 seconds 90 seconds 90 seconds (variable)
Fail-Safe 35 seconds 35 seconds 35 seconds
Actuator Travel 32 mm (1.25”) 32 mm (1.25”) 32 mm (1.25”)
Actuator Noise Level 60 dB(A) 60 dB(A) 60 dB(A)
GVL LINKAGES
FGVL Flanged valves adjustable for 2½” to 4” $2,165 $2,021 $2,260**
WGVL Warren Controls Type 20, 22, 30, 32 $1,204 $1,732 $1,327**
* 4-20 mA with 500 Ω resistor ZG-R01
**Prices do not reflect additional programming codes surcharge. See page 21-14 for linear actuator MFT codes.
Note: All “B” versions available as customizable “X” versions. Please see www.belimo.us for details.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

21-13
Globe Valve Retrofit Actuators for UGLK Series
Actuator Selection Guide

ROTARY ACTUATORS SUGGESTION


Tandem Standard
Spring Electronic Feedback Power
SERIES TORQUE MODEL Mounting Control Input Running List Price
Return Fail-Safe Position Supply
Available Time
LF24 US • On/Off - 24 VAC/DC $381
35 in-lbs
LF Series* Variable with MFT
[4 Nm] LF24-MFT US • variable VDC 24 VAC/DC $591
(VDC, PWM, Floating Point, On/Off)
NFBUP-X1 • On/Off - 24-240 VAC $512
90 in-lbs
NF Series* (24 VAC/DC) Variable with MFT
[10 Nm] NFX24-MFT-X1 • variable VDC 24 VAC/DC $672
(VDC, PWM, Floating Point, On/Off)
AFBUP-X1 • • On/Off - 24-240 VAC $635
180 in-lbs
AF Series* Variable with MFT
[20 Nm] AFX24-MFT-X1 • • variable VDC 24 VAC/DC $778

Consult Specifications
(VDC, PWM, Floating Pt., On/Off)
LMB24-3-X1 Floating Point, On/Off - 24 VAC/DC $218
45 in-lbs
LM Series* Variable with MFT
[5 Nm] LMX24-MFT-X1 variable VDC 24 VAC/DC $438
(VDC, PWM, Floating Point, On/Off)
NMB24-3-X1 Floating Point, On/Off - 24 VAC/DC $299
90 in-lbs
NM Series* Variable with MFT
[10 Nm] NMX24-MFT-X1 variable VDC 24 VAC/DC $516
(VDC, PWM, Floating Point, On/Off)
AMB24-3-X1 Floating Point, On/Off - 24 VAC/DC $421
180 in-lbs
AM Series* Variable with MFT
[20 Nm] AMX24-MFT-X1 variable VDC 24 VAC/DC $650
(VDC, PWM, Floating Point, On/Off)
GMB24-3-X1 Floating Point, On/Off - 24 VAC/DC $573
360 in-lbs
GM Series* Variable with MFT
[40 Nm] GMX24-MFT-X1 • variable VDC 24 VAC/DC $839
(VDC, PWM, Floating Point, On/Off)
GKB24-3-X1 • Floating Point, On/Off - 24 VAC $1,270
360 in-lbs
GK Series* Variable with MFT
[40 Nm] GKX24-MFT-X1 • • variable VDC 24 VAC/DC $1,747
(VDC, PWM, Floating Point, On/Off)
*Please consult the damper actuator sections for a full list of product offerings. Standard run times should be considered in the selection. All airside products are applicable for retrofit kits.
Select “X1” actuators come with a handle.

MULTI-FUNCTION TECHNOLOGY
PROGRAMMING CODE Control Input Running Time Built-in Feedback List Price
P-10001 A01 2-10 VDC 150 seconds 2-10 VDC No Charge
P-10002 A02 0.5-10 VDC 150 seconds 0.5-10 VDC No Charge
ROTARY ACTUATOR

P-10028 A28 0.5-10 VDC 150 seconds 0.5-10 VDC No Charge


RETROFIT SOLUTIONS

P-10063 A63 0.5-4.5 VDC 150 seconds 0.5-4.5 VDC No Charge


P-10064 A64 5.5-10 VDC 150 seconds 5.5-10 VDC No Charge
P-20002 W02 0.02-5.00 seconds PWM 150 seconds 2-10 VDC No Charge

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


P-20003 W03 0.10-25.5 seconds PWM 150 seconds 2-10 VDC No Charge
P-30001 F01 Floating Point 150 seconds 2-10 VDC No Charge
P-40002 J02 On/Off 150 seconds 2-10 VDC No Charge
G01 On/Off 35 seconds 2-10 VDC MFT only No Charge
G02 On/Off 60 seconds 2-10 VDC MFT only No Charge

All prices are in US Dollars (USD)


G03 On/Off 90 seconds 2-10 VDC MFT only No Charge
G04 On/Off 150 seconds 2-10 VDC MFT only No Charge
G11 Floating Point 35 seconds 2-10 VDC MFT only No Charge
G12 Floating Point 60 seconds 2-10 VDC MFT only No Charge
G13 Floating Point 90 seconds 2-10 VDC MFT only No Charge
G14 Floating Point 150 seconds 2-10 VDC MFT only No Charge
G41(G21 for -SR) 2-10 VDC 35 seconds 2-10 VDC No Charge
LINEAR ACTUATOR

G42 (G22 for -SR) 2-10 VDC 60 seconds 2-10 VDC No Charge
G43 (G23 for -SR) 2-10 VDC 90 seconds 2-10 VDC No Charge
G44 (G24 for -SR) 2-10 VDC 150 seconds 2-10 VDC No Charge
G51 0.5-10 VDC 35 seconds 0.5-10 VDC No Charge
G52 0.5-10 VDC 60 seconds 0.5-10 VDC No Charge
G53 0.5-10 VDC 90 seconds 0.5-10 VDC No Charge
G54 0.5-10 VDC 150 seconds 0.5-10 VDC No Charge
G2A 5.5-10 VDC 150 seconds 5.5-10 VDC No Charge
G2B 0.5-4.5 VDC 150 seconds 0.5-4.5 VDC No Charge
G2C 2-10 VDC 150 seconds 0.5-5 VDC No Charge
G2D 6-9 VDC 150 seconds 2-10 VDC No Charge
G2E 10.5-13.5 VDC 150 seconds 2-10 VDC No Charge
W3M 0.02-5.00 seconds PWM 90 seconds 2-10 VDC No Charge
W3P 0.2-5.00 seconds PWM 90 seconds 2-10 VDC No Charge

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

21-14
UGLK Retrofit Solution
Components

UGLK Collars* Most Commonly Used Valve Style


Part Number Inside Diameter Description Style 1 Style 2 Style 3 Style 4 Style 5 List Price
UGLK-COL-1005 1.000” 3 setscrews, for frame type • $203
UGLK-COL-1063 1.063” 3 setscrews, for frame type • $203
UGLK-COL-1100 1.100” 3 setscrews, for frame type, counterbored top • $203
UGLK-COL-1255 1.250” 3 setscrews, for frame type • $203
UGLK-COL-1315 1.315” 3 setscrews, for frame type, can be used with VB7 with shim • $203
UGLK-COL-1375 1.375” 3 setscrews, for frame type • $203
UGLK-COL-BC10 1.250”- 16 Thd. Fits Siebe VB7/VB9. Use on frame type only • $203
UGLK-COL-HY02 1.370” 1 setscrew, for frame type • $203
UGLK-COL-LG02 1.740” 1 setscrew, for frame type • $203
UGLK-COL-LG04 1.740” 1 setscrew, for frame type • $203
UGLK-COL-JC05 1.070” 3 setscrews, for frame type • $203
UGLK-COL-JC06 1.562- 14 Thd. Threaded, brass • $203
UGLK-COL-JC08 0.760” 3 setscrews, for frame type, counterbored top • $203
UGLK-COL-JC15 1.070” Ring, no setscrews • $203
UGLK-COL-0880 0.880” 3 setscrews, for frame type, counterbored top • $203
UGLK-COL-WNUT 1.375”- 20 Thd. Replacement Warren nut. Will not go over damaged threads • $203
UGLK-COL-AD01 1.250”- 16 Thd. Fits Siebe VB7/VB9. For VB7 frame only • $203
UGLK-COL-UNIV Custom 3 setscrews, for frame type. Must be machined • • • • $356
UGSL-ADPT Custom Custom collar for UGSL1200. Must be machined $84
* Must reuse retaining clip and set screws.

UGLK Stem Adapters Most Commonly Used Valve Style


Part Number Inside Diameter Description Style 1 Style 2 Style 3 Style 4 Style 5 List Price
UGLK-STM-1800 1/4”- 28 Stem Thd. Stem adapter for 1/4”- 28 valve stems • • • • • $113
UGLK-STM-1801 3/8”- 24 Stem Thd. Stem adapter for 3/8”- 24 valve stems • • • • • $113
UGLK-STM-1802 1/2”- 20 Stem Thd. Stem adapter for 1/2”- 20 valve stems • • • $113
UGLK-STM-1803 7/16”- 20 Stem Thd. Stem adapter for 7/16”- 20 valve stems • $113
UGLK-STM-1501 3/8”- 24 Stem Thd. For Warren FLG valves with UGLK • $113
UGLK-STM-1805 3/8” OD Grooved Landis 2.5-3” -599 Series • $113
UGLK-STM-2305 1/2” OD Grooved Landis 4-6” -599 Series • $113
UGLK-STM-UNIV Custom Must be machined • • • • • $163

RETROFIT SOLUTIONS
UGLK Stem Adapters UGLK Collars

Back Plate
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.
All prices are in US Dollars (USD)

Style 4
Style 2
Anti-Rotation
Gear
Screw Actuator Plate Style 1

Drive Shaft

Rack

Box Frame
Set Screw Style 5
Style 3
Stem Adapter

Retaining Ring
Jam Nut
Base Bracket

Set Screw
Collar

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

21-15
Honeywell
VP5.., V5011, V5013, V5045 Series Valves
Linkage/Actuator Selection Guide

Belimo Belimo Linkage


Valve Body Model Size Fail-Safe Close-Off (psi)
Actuator Series Linkage List Price
No CM UGLK1808 $482
VP526 Series 58
Yes TF UGLK1808 $482
5/8”
No CM UGLK1808 $482
VP531 Series 70
Yes TF UGLK1808 $482
No CM UGLK1808 $482
VP531 Series 7/8” 70
Yes TF UGLK1808 $482
No LV UGVL Pg # 21-12
V5011 Series 236 LVK UGVL Pg # 21-13
Yes
LF UGLK1806 $667
V5011F NF UGLK1800 $667
Yes 236
(1014, 1022, 1030, 1048, 1121, 1139) LF UGLK1806 $667
V5011G NF UGLK1800 $667
Yes 236
(1137, 1145, 1152, 1160, 1178, 1186) LF UGLK1806 $667
NF UGLK1800 $667
V5011H (1002, 1010) Yes 236
LF UGLK1806 $667
NF UGLK1800 $667
V5011J (1012, 1079) Yes 236
LF UGLK1806 $667
No LV UGVL Pg # 21-12
V5013 Series 236
Yes LVK UGVL Pg # 21-13
NF UGLK1800 $667
V5013F (1004, 1012, 1079) ½” Yes 236
LF UGLK1806 $667
No LV UGVL Pg # 21-12
V5013N Series 236 LVK UGVL Pg # 21-13
Yes
LF UGLK1806 $667
No AM UGLK1804 $554
V5045 236
Yes NF UGLK1804 $554
No CM UGLK1808 $482
VP525 Series 110
Yes TF UGLK1808 $482
No CM UGLK1808 $482
VP526 Series 50
Yes TF UGLK1808 $482
No CM UGLK1808 $482
VP527 Series 45
Yes TF UGLK1808 $482
No CM UGLK1808 $482
RETROFIT SOLUTIONS

VP531 Series 70
Yes TF UGLK1808 $482
Yes 236 NF UGLK1800 $667
V5011 (H1028, G1194, J1023)
Yes 110 LF UGLK1806 $667
No LV UGVL Pg # 21-12

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


211
V5011 Series Yes LVK UGVL Pg # 21-13
Yes 110 LF UGLK1806 $667
Yes 236 NF UGLK1800 $667
V5011F (1055, 1147)
Yes 110 LF UGLK1806 $667
No LV UGVL Pg # 21-12
V5013 Series 211

All prices are in US Dollars (USD)


Yes LVK UGVL Pg # 21-13
¾” Yes 236 NF UGLK1800 $667
V5013F (1020, 1087)
Yes 110 LF UGLK1806 $667
No LV UGVL Pg # 21-12
211
V5013N Series Yes LVK UGVL Pg # 21-13
Yes 110 LF UGLK1806 $667
V5045 Yes 236 NF UGLK1804 $554
No CM UGLK1808 $482
VP525 Series 55
Yes TF UGLK1808 $482
No CM UGLK1808 $482
VP531 Series 70
Yes TF UGLK1808 $482
Yes 236 AF UGLK1800 $667
V5011 (F1063, F1154, H1028, G1194)
Yes 65 LF UGLK1806 $667
No LV UGVL Pg # 21-12
93
Yes LVK UGVL Pg # 21-13
No SV UGVL Pg # 21-12
V5011 Series
236 SVK UGVL Pg # 21-13
1” Yes
AF UGLK1800 $667
Yes 65 LF UGLK1806 $667
No LV UGVL Pg # 21-12
93
Yes LVK UGVL Pg # 21-13
V5013 Series
No SV UGVL Pg # 21-12
236
Yes SVK UGVL Pg # 21-13

All close-off pressures listed are approximate and actual close-off pressures are based on valve condition and application.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

21-16
Honeywell
V5013, V5045, V5011 Series Valves
Linkage/Actuator Selection Guide

Belimo Belimo Linkage


Valve Body Model Size Fail-Safe Close-Off (psi)
Actuator Series Linkage List Price
Yes 236 AF UGLK1800 $667
V5013F (1038, 1095)
Yes 65 LF UGLK1806 $667
No LV UGVL Pg # 21-12
93
Yes LVK UGVL Pg # 21-13
No SV UGVL Pg # 21-12
V5013N Series 1”
236 SVK UGVL Pg # 21-13
Yes
AF UGLK1800 $667
Yes 65 LF UGLK1806 $667
No AM UGLK1804 $554
V5045 236
Yes NF UGLK1804 $554
Yes 221 AF UGLK1800 $667
V5011 (H1044, G1210, J1049)
Yes 40 LF UGLK1806 $667
Yes 221 AF UGLK1800 $667
No SV UGVL Pg # 21-12
V5011 Series 236
Yes SVK UGVL Pg # 21-13
Yes 40 LF UGLK1806 $667
Yes 221 AF UGLK1800 $667
V5011F (1071, 1162)
Yes 40 LF UGLK1806 $667
No SV UGVL Pg # 21-12
V5013 Series 1¼” 236
Yes SVK UGVL Pg # 21-13
Yes 221 AF UGLK1800 $667
V5013F (1046, 1103)
Yes 40 LF UGLK1806 $667
Yes 221 AF UGLK1800 $667
No SV UGVL Pg # 21-12
V5013N Series 236
Yes SVK UGVL Pg # 21-13
Yes 40 LF UGLK1806 $667
No 236 AM UGLK1804 $554
V5045
Yes 160 NF UGLK1804 $554
Yes 153 AF UGLK1800 $667
V5011 (F1089, F1178, G1228)
Yes 26 LF UGLK1806 $667
Yes 153 AF UGLK1800 $667
No SV UGVL Pg # 21-12
V5011 Series 160
Yes SVK UGVL Pg # 21-13

RETROFIT SOLUTIONS
Yes 26 LF UGLK1806 $667
No SV UGVL Pg # 21-12
V5013 Series 160
Yes SVK UGVL Pg # 21-13
1½”
Yes 153 AF UGLK1800 $667
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

V5013F (1053, 1111)


Yes 26 LF UGLK1806 $667
Yes 153 AF UGLK1800 $667
No SV UGVL Pg # 21-12
V5013N Series 160
Yes SVK UGVL Pg # 21-13
Yes 26 LF UGLK1806 $667
All prices are in US Dollars (USD)

No AM UGLK1804 $554
V5045 211
Yes AF UGLK1804 $554
Yes 86 AF UGLK1800 $667
Yes 173 GK UGLK1800 $667
V5011 (F1097, F1188, G1103)
Yes 40 NF UGLK1800 $667
Yes 14 LF UGLK1806 $667
Yes 86 AF UGLK1800 $667
Yes 173 GK UGLK1800 $667
V5011 Series No SV UGVL Pg # 21-12
85
Yes SVK UGVL Pg # 21-13
Yes 14 LF UGLK1806 $667
No SV UGVL Pg # 21-12
V5013 Series 85
Yes SVK UGVL Pg # 21-13
2”
Yes 86 AF UGLK1800 $667
Yes 173 GK UGLK1800 $667
V5013F (1061, 1129)
Yes 40 NF UGLK1800 $667
Yes 14 LF UGLK1806 $667
Yes 86 AF UGLK1800 $667
Yes 173 GK UGLK1800 $667
V5013N Series No SV UGVL Pg # 21-12
85
Yes SVK UGVL Pg # 21-13
Yes 14 LF UGLK1806 $667
No AM UGLK1804 $554
V5045 120
Yes AF UGLK1804 $554

All close-off pressures listed are approximate and actual close-off pressures are based on valve condition and application.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

21-17
Honeywell
V3350, V3351, V3360, V3450, V3451, V3460, V5011, V5013 Series Valves
Linkage/Actuator Selection Guide

Belimo Belimo Linkage


Valve Body Model Size Fail-Safe Close-Off (psi)
Actuator Series Linkage List Price
Yes 211 2*GK UGLK1870 $846
V3350 Yes 110 2*AF UGLK1870 $846
(A2009, A2017, B2007, C2013, D2003) No SV UGVL Pg # 21-12
55
Yes SVK UGVL Pg # 21-13
Yes 211 2*GK UGLK1870 $846
Yes 110 2*AF UGLK1870 $846
V3351 (A2008, C2005, D2002)
No SV UGVL Pg # 21-12
55
Yes SVK UGVL Pg # 21-13
Yes 211 2*GK UGLK1870 $846
Yes 110 2*AF UGLK1870 $846
V3360E2008, V3361E2007 No SV UGVL Pg # 21-12
55
Yes SVK UGVL Pg # 21-13
Yes 52 AF UGLK1800 $667
Yes 211 2*GK UGLK1870 $846
Yes 110 2*AF UGLK1870 $846
V3450
No SV UGVL Pg # 21-12
(A2008, A2016, B2006, C2012, D2002) 55
Yes SVK UGVL Pg # 21-13
2½” Yes 52 AF UGLK1800 $667
Yes 211 2*GK UGLK1870 $846
Yes 110 2*AF UGLK1870 $846
V3451 (A2007, C2003, C2004) No SV UGVL Pg # 21-12
77
Yes SVK UGVL Pg # 21-13
Yes 52 AF UGLK1800 $667
Yes 211 2*GK UGLK1870 $846
Yes 110 2*AF UGLK1870 $846
V3460E2007, V3461E2006 No SV UGVL Pg # 21-12
55
Yes SVK UGVL Pg # 21-13
Yes 52 AF UGLK1800 $667
V5011 (A1734, F1105, F1196, G1111) Yes 211 2*GK UGLK1870 $846
No SV UGVL Pg # 21-12
V5011 Series 52
Yes SVK UGVL Pg # 21-13
Yes 211 2*GK UGLK1870 $846
V5013 (B1003, C1001)
Yes 52 AF UGLK1800 $667
RETROFIT SOLUTIONS

No SV UGVL Pg # 21-12
V5013 Series 52
Yes SVK UGVL Pg # 21-13
Yes 77 2*AF UGLK1870 $846
Yes 38 AF UGLK1800 $667

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


V3350
Yes 136 2*GK UGLK1870 $846
(A3007, A3015, B3005, C3011, D3001)
No SV UGVL Pg # 21-12
38
Yes SVK UGVL Pg # 21-13
Yes 77 2*AF UGLK1870 $846
Yes 38 AF UGLK1800 $667

All prices are in US Dollars (USD)


V3351 (A3006, C3002, C3003) Yes 136 2*GK UGLK1870 $846
No SV UGVL Pg # 21-12
38
Yes SVK UGVL Pg # 21-13
Yes 77 2*AF UGLK1870 $846
Yes 38 AF UGLK1800 $667
V3360E3006, V3361E3005 Yes 136 2*GK UGLK1870 $846
No SV UGVL Pg # 21-12
38
Yes SVK UGVL Pg # 21-13
3”
Yes 77 2*AF UGLK1870 $846
Yes 38 AF UGLK1800 $667
V3450
Yes 136 2*GK UGLK1870 $846
(A3006, A3014, B3004, C3010, D3000)
No SV UGVL Pg # 21-12
38
Yes SVK UGVL Pg # 21-13
Yes 77 2*AF UGLK1870 $846
Yes 38 AF UGLK1800 $667
V3451 (A3005, C3001, C3002) Yes 136 2*GK UGLK1870 $846
No SV UGVL Pg # 21-12
38
Yes SVK UGVL Pg # 21-13
Yes 77 2*AF UGLK1870 $846
Yes 38 AF UGLK1800 $667
V3460E3005, V3461E3004 Yes 136 2*GK UGLK1870 $846
No SV UGVL Pg # 21-12
38
Yes SVK UGVL Pg # 21-13

All close-off pressures listed are approximate and actual close-off pressures are based on valve condition and application.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

21-18
Honeywell
V5011, V5013, V3350, V3351, V3360, V3450, V3451, V3460 Series Valves
Linkage/Actuator Selection Guide

Belimo Belimo Linkage


Valve Body Model Size Fail-Safe Close-Off (psi)
Actuator Series Linkage List Price
Yes 38 AF UGLK1800 $667
V5011 (A1767, F1113, F1204, G1129)
Yes 136 2*GK UGLK1870 $846
No SV UGVL Pg # 21-12
V5011 Series 40
Yes SVK UGVL Pg # 21-13
3”
Yes 77 GK UGLK1800 $667
V5013 (B1011, C1019)
Yes 136 2*GK UGLK1870 $846
No SV UGVL Pg # 21-12
V5013 Series 40
Yes SVK UGVL Pg # 21-13
No EV FGVL Pg # 21-12
22
Yes 2*AF UGLK1872 $840
V3350
No RV FGVL Pg # 21-12
(A4005, A4013, B4003, C4019, D4009) 40
Yes 2*GK UGLK1872 $840
Yes 10 AF UGLK1802 $667
No EV FGVL Pg # 21-12
22
Yes 2*AF UGLK1872 $840
V3351 ( A4004, C4000, C4001) No RV FGVL Pg # 21-12
40
Yes 2*GK UGLK1872 $840
Yes 10 AF UGLK1802 $667
No EV FGVL Pg # 21-12
22
Yes 2*AF UGLK1872 $840
V3360E4004, V3361E4003 No RV FGVL Pg # 21-12
40
Yes 2*GK UGLK1872 $840
Yes 10 AF UGLK1802 $667
No EV FGVL Pg # 21-12
22
Yes 2*AF UGLK1872 $840
V3450
No RV FGVL Pg # 21-12
(A4004, A4012, B4002, C4018, D4008) 40
Yes 2*GK UGLK1872 $840
4”
Yes 10 AF UGLK1802 $667
No EV FGVL Pg # 21-12
22
Yes 2*AF UGLK1872 $840
V3451 (A4003, C4000, C4009) No RV FGVL Pg # 21-12
40
Yes 2*GK UGLK1872 $840
Yes 10 AF UGLK1802 $667

RETROFIT SOLUTIONS
No EV FGVL Pg # 21-12
22
Yes 2*AF UGLK1872 $840
V3460E4003, V3461E4002 No RV FGVL Pg # 21-12
40
Yes 2*GK UGLK1872 $840
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

Yes 10 AF UGLK1802 $667


No 22 EV FGVL Pg # 21-12
No RV FGVL Pg # 21-12
V5011 (A1858, B1013) 40
Yes 2*GK UGLK1872 $840
Yes 10 AF UGLK1802 $667
All prices are in US Dollars (USD)

No EV FGVL Pg # 21-12
22
Yes GK UGLK1802 $667
V5013 (B1029, C1027)
No RV FGVL Pg # 21-12
40
Yes 2*GK UGLK1872 $840
No RV FGVL Pg # 21-12
22
Yes 2*GK UGLK1872 $840
V3350 No EV FGVL Pg # 21-12
(A5002, A5010, B5000, C5016, D5006) 14 GK UGLK1802 $667
Yes
2*AF UGLK1872 $840
Yes 10 AF UGLK1802 $667
No RV FGVL Pg # 21-12
22
Yes 2*GK UGLK1872 $840
No EV FGVL Pg # 21-12
V3351 (A5001, C5008, D5005) 5”
14 GK UGLK1802 $667
Yes
2*AF UGLK1872 $840
Yes 10 AF UGLK1802 $667
No RV FGVL Pg # 21-12
22
Yes 2*GK UGLK1872 $840
No EV FGVL Pg # 21-12
V3360E5001, V3361E5000
14 GK UGLK1802 $667
Yes
2*AF UGLK1872 $840
Yes 10 AF UGLK1802 $667

All close-off pressures listed are approximate and actual close-off pressures are based on valve condition and application.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

21-19
Honeywell
V3360, V3450, V3451, V3460, V5011, V5013, V3350, V3351, VGF2, VGF3 Series Valves
Linkage/Actuator Selection Guide

Belimo Belimo Linkage


Valve Body Model Size Fail-Safe Close-Off (psi)
Actuator Series Linkage List Price
No RV FGVL Pg # 21-12
22
Yes 2*GK UGLK1872 $840
V3450 No EV FGVL Pg # 21-12
(A5001, A5019, B5009, C5015, D5005) 14 GK UGLK1802 $667
Yes
2*AF UGLK1872 $840
Yes 10 AF UGLK1802 $667
No RV FGVL Pg # 21-12
22
Yes 2*GK UGLK1872 $840
No EV FGVL Pg # 21-12
V3451 (A5000, C5006, C5007)
14 GK UGLK1802 $667
Yes
2*AF UGLK1872 $840
Yes 10 AF UGLK1802 $667
No RV FGVL Pg # 21-12
22
Yes 2*GK UGLK1872 $840
5” No EV FGVL Pg # 21-12
V3460E5000, V3461E5009
14 GK UGLK1802 $667
Yes
2*AF UGLK1872 $840
Yes 10 AF UGLK1802 $667
No RV FGVL Pg # 21-12
22
Yes 2*GK UGLK1872 $840
V5011 (A1882, B1047) GK UGLK1802 $667
Yes 14
2*AF UGLK1872 $840
Yes 10 AF UGLK1802 $667
No RV FGVL Pg # 21-12
22
Yes 2*GK UGLK1872 $840
No EV FGVL Pg # 21-12
V5013 (B1037, C1035)
14 GK UGLK1802 $667
Yes
2*AF UGLK1872 $840
Yes 10 AF UGLK1802 $667
No RV FGVL Pg # 21-12
22
V3350 Yes 2*GK UGLK1872 $840
(A6000, A6008, A6018, C6014, D6004) GK UGLK1802 $667
Yes 10
2*AF UGLK1872 $840
RETROFIT SOLUTIONS

No RV FGVL Pg # 21-12
22
Yes 2*GK UGLK1872 $840
V3351 (A6009, C6005, C6006)
GK UGLK1802 $667
Yes 10
2*AF UGLK1872 $840

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


No RV FGVL Pg # 21-12
22
Yes 2*GK UGLK1872 $840
V3360E6009, V3361E6008
GK UGLK1802 $667
Yes 10
2*AF UGLK1872 $840
No RV FGVL Pg # 21-12
22

All prices are in US Dollars (USD)


V3450 Yes 2*GK UGLK1872 $840
(A6009, A6007, A6017, C6013, D6003) GK UGLK1802 $667
Yes 10
2*AF UGLK1872 $840
6”
No RV FGVL Pg # 21-12
22
Yes 2*GK UGLK1872 $840
V3451 (A6008, C6004, C6005)
GK UGLK1802 $667
Yes 10
2*AF UGLK1872 $840
No RV FGVL Pg # 21-12
22
Yes 2*GK UGLK1872 $840
V3460E6008, V3461E6007
GK UGLK1802 $667
Yes 10
2*AF UGLK1872 $840
No RV FGVL Pg # 21-12
22
Yes 2*GK UGLK1872 $840
V5011 (A1916, B1078)
GK UGLK1802 $667
Yes 10
2*AF UGLK1872 $840
No RV FGVL Pg # 21-12
22
Yes 2*GK UGLK1872 $840
V5013 (B1045, C1043)
GK UGLK1802 $667
Yes 10
2*AF UGLK1872 $840
No EV FGVL Pg # 21-12
VGF2.. Series
Yes AVK FGVL Pg # 21-13
2½” 52
No EV FGVL Pg # 21-12
VGF3.. Series
Yes AVK FGVL Pg # 21-13

All close-off pressures listed are approximate and actual close-off pressures are based on valve condition and application.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

21-20
Honeywell Johnson Controls
VGF2, VGF3 Series Valves V-37, V-38, V-39, V-43, VG7, VTM, V(B)-37, V(B)-39, V(B)-43, V(B)-58 Series Valves
Linkage/Actuator Selection Guide Linkage/Actuator Selection Guide

Belimo Belimo Linkage


Valve Body Model Size Fail-Safe Close-Off (psi)
Actuator Series Linkage List Price
No EV FGVL Pg # 21-12
VGF2.. Series
Yes AVK FGVL Pg # 21-13
3” 40
No EV FGVL Pg # 21-12
VGF3.. Series
Yes AVK FGVL Pg # 21-13
VGF2.. Series No 50 EV FGVL Pg # 21-12
4”
VGF3.. Series No 50 EV FGVL Pg # 21-12
VGF2.. Series No 40 RV FGVL Pg # 21-12
5”
VGF3.. Series No 40 RV FGVL Pg # 21-12
VGF2.. Series No 30 RV FGVL Pg # 21-12
6”
VGF3.. Series No 30 RV FGVL Pg # 21-12
JOHNSON CONTROLS
No LM UGLK1552 $426
V-3766 236
Yes LF UGLK1552 $426
No LM UGLK1554 $426
V-3854-5 236
Yes LF UGLK1554 $426
No LM UGLK1552 $426
V-3966 236
Yes LF UGLK1552 $426
No LV UGVL Pg # 21-12
V-4332 236
½” Yes LVK UGVL Pg # 21-13
No LV UGVL Pg # 21-12
VG7000 Series 236
Yes LVK UGVL Pg # 21-13
VG7XXX-(C, E, GT) *Threaded Stem Only Yes 236 LF UGLK1416 $557
No LM UGLK1550 $426
VTM-TN-(007, 019, 047) LF UGLK1550 $426
236
*Threaded Stem Only Yes LV UGVL Pg # 21-12
LVK UGVL Pg # 21-13
No LV UGVL Pg # 21-12
V(B)-3754 Series, Bronze Trim 211
Yes LVK UGVL Pg # 21-13
No LV UGVL Pg # 21-12
V(B)-3974 Series, Bronze Trim 211
Yes LVK UGVL Pg # 21-13
No LV UGVL Pg # 21-12
V(B)-4324 Series, Bronze Trim 211
Yes LVK UGVL Pg # 21-13
No LV UGVL Pg # 21-12

RETROFIT SOLUTIONS
V(B)-5844 Series 211
Yes LVK UGVL Pg # 21-13
¾”
V-3754-(4, 1008, 1022, 1026) Yes 211 LF UGLK1550 $426
V-3974-(4, 1004, 1010) Yes 211 LF UGLK1550 $426
V-4324-(4, 1005, 1006, 1013) Yes 211 LF UGLK1550 $426
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

No LV UGVL Pg # 21-12
V-4332
Yes LVK UGVL Pg # 21-13
211
No LV UGVL Pg # 21-12
VG7000 Series
Yes LVK UGVL Pg # 21-13
VG7XXX-LT *Threaded Stem Only Yes 169 LF UGLK1416 $557
All prices are in US Dollars (USD)

No LV UGVL Pg # 21-12
93
Yes LVK UGVL Pg # 21-13
V(B)-3754 Series, Bronze Trim
No SV UGVL Pg # 21-12
236
Yes SVK UGVL Pg # 21-13
No LV UGVL Pg # 21-12
93
Yes LVK UGVL Pg # 21-13
V(B)-3974 Series, Bronze Trim
No SV UGVL Pg # 21-12
236
Yes SVK UGVL Pg # 21-13
No LV UGVL Pg # 21-12
V(B)-4324 Series, Bronze Trim 93
Yes LVK UGVL Pg # 21-13
No SV UGVL Pg # 21-12
V(B)-4324 Series, Bronze Trim 1” 236
Yes SVK UGVL Pg # 21-13
No LV UGVL Pg # 21-12
93
Yes LVK UGVL Pg # 21-13
V(B)-5844 Series
No SV UGVL Pg # 21-12
236
Yes SVK UGVL Pg # 21-13
Yes 173 NF UGLK1402 $614
V-3754-(5, 1010, 1023, 1027)
Yes 236 AF UGLK1402 $614
Yes 173 NF UGLK1402 $614
V-3974-(5, 1005, 1011)
Yes 236 AF UGLK1402 $614
Yes 173 NF UGLK1402 $614
V-4324-(5, 1007, 1008, 1014)
Yes 236 AF UGLK1402 $614

All close-off pressures listed are approximate and actual close-off pressures are based on valve condition and application.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

21-21
Johnson Controls
V(B)-58, V-37, V-39, V-43, VG7, V(B)-37, V(B)-39, V(B)-43, V(B)-58, V-52, V-54 Series Valves
Linkage/Actuator Selection Guide

Belimo Belimo Linkage


Valve Body Model Size Fail-Safe Close-Off (psi)
Actuator Series Linkage List Price
No LV UGVL Pg # 21-12
93
Yes LVK UGVL Pg # 21-13
V-4332
No SV UGVL Pg # 21-12
236
Yes SVK UGVL Pg # 21-13
1” No LV UGVL Pg # 21-12
93
Yes LVK UGVL Pg # 21-13
VG7000 Series
No SV UGVL Pg # 21-12
236
Yes SVK UGVL Pg # 21-13
VG7XXX-NT *Threaded Stem Only Yes 93 LF UGLK1418 $557
No SV UGVL Pg # 21-12
V(B)-3754 Series, Bronze Trim 236
Yes SVK UGVL Pg # 21-13
No SV UGVL Pg # 21-12
V(B)-3974 Series, Bronze Trim 236
Yes SVK UGVL Pg # 21-13
No SV UGVL Pg # 21-12
V(B)-4324 Series, Bronze Trim 236
Yes SVK UGVL Pg # 21-13
No SV UGVL Pg # 21-12
V(B)-5844 Series 236
Yes SVK UGVL Pg # 21-13
1¼” Yes 221 AF UGLK1402 $614
V-3754-8
Yes 110 NF UGLK1402 $614
Yes 221 AF UGLK1402 $614
V-4324-8
Yes 110 NF UGLK1402 $614
No SV UGVL Pg # 21-12
V-4332 236
Yes SVK UGVL Pg # 21-13
No SV UGVL Pg # 21-12
VG7000 Series 236
Yes SVK UGVL Pg # 21-13
VG7XXX-PT *Threaded Stem Only Yes 65 LF UGLK1418 $557
No SV UGVL Pg # 21-12
V(B)-3754 Series, Bronze Trim 160
Yes SVK UGVL Pg # 21-13
No SV UGVL Pg # 21-12
V(B)-3974 Series, Bronze Trim 160
Yes SVK UGVL Pg # 21-13
No SV UGVL Pg # 21-12
V(B)-4324 Series, Bronze Trim 160
Yes SVK UGVL Pg # 21-13
No SV UGVL Pg # 21-12
RETROFIT SOLUTIONS

V(B)-5844 Series 160


Yes SVK UGVL Pg # 21-13
Yes 77 NF UGLK1402 $614
Yes 153 AF UGLK1402 $614
V-3754-(6, 1028, 1029, 1030)
Yes 236 GK UGLK1402 $614

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


Yes 211 2*AF UGLK1478 $849
Yes 77 NF UGLK1402 $614
Yes 153 AF UGLK1402 $614
V-3974-(6, 1012, 1013)
Yes 236 GK UGLK1402 $614
Yes 211 2*AF UGLK1478 $849

All prices are in US Dollars (USD)


Yes 77 NF UGLK1402 $614
Yes 153 AF UGLK1402 $614
V-4324-(6,1015, 1016, 1017)
Yes 236 GK UGLK1402 $614
1½”
Yes 211 2*AF UGLK1478 $849
No SV UGVL Pg # 21-12
V-4332 160
Yes SVK UGVL Pg # 21-13
Yes 77 NF UGLK1404 $614
No AM UGLK1404 $614
153
V-5254-(1, 2, 3, 11) Yes AF UGLK1404 $614
GM UGLK1404 $614
No 236
2*GM UGLK1472 $854
GK UGLK1404 $614
V-5254-(1, 2, 3, 11) Yes 236 2*AF UGLK1472 $854
2*GK UGLK1472 $854
Yes 77 NF UGLK1404 $614
No AM UGLK1404 $614
153
Yes AF UGLK1404 $614
GM UGLK1404 $614
V-5464-(1, 2, 11) No
2*GM UGLK1472 $854
236 GK UGLK1404 $614
Yes 2*AF $854
UGLK1472
2*GK $854

All close-off pressures listed are approximate and actual close-off pressures are based on valve condition and application.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

21-22
Johnson Controls
V-58, VG7, V(B)-37, V(B)-39, V(B)-43, V(B)-58, V-37, V-39, V-43, V-52, V-54 Series Valves
Linkage/Actuator Selection Guide

Belimo Belimo Linkage


Valve Body Model Size Fail-Safe Close-Off (psi)
Actuator Series Linkage List Price
Yes 77 NF UGLK1404 $614
Yes 153 AF UGLK1404 $614
No 2*GM UGLK1472 $854
V-5844-(1, 2, 3, 11)
GK UGLK1404 $614
236
Yes 2*AF $854
UGLK1472
2*GK $854
1½” No SV UGVL Pg # 21-12
VG7000 Series 160
Yes SVK UGVL Pg # 21-13
Yes 77 NF UGLK1422 $614
Yes 153 AF UGLK1422 $614
VG7XXX-RT *Threaded Stem Only No GM UGLK1422 $614
236
Yes GK UGLK1422 $614
Yes 26 LF UGLK1420 $557
No SV UGVL Pg # 21-12
V(B)-3754 Series, Bronze Trim 85
Yes SVK UGVL Pg # 21-13
No SV UGVL Pg # 21-12
V(B)-3974 Series, Bronze Trim 85
Yes SVK UGVL Pg # 21-13
No SV UGVL Pg # 21-12
V(B)-4324 Series, Bronze Trim 85
Yes SVK UGVL Pg # 21-13
No SV UGVL Pg # 21-12
V(B)-5844 Series 85
Yes SVK UGVL Pg # 21-13
Yes 86 AF UGLK1406 $614
No GM UGLK1406 $614
173 GK UGLK1406 $614
Yes
V-3754-7 2*AF UGLK1474 $849
No 2*GM UGLK1474 $849
236
Yes 2*GK UGLK1474 $849
Yes 40 NF UGLK1406 $614
Yes 86 AF UGLK1406 $614
No GM UGLK1406 $614
173 GK UGLK1406 $614
Yes
V-3974-7 2*AF UGLK1474 $849
No 2*GM UGLK1474 $849

RETROFIT SOLUTIONS
236
Yes 2*GK UGLK1474 $849
Yes 40 NF UGLK1406 $614
Yes 86 AF UGLK1406 $614
2” No GM UGLK1406 $614
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

173 GK UGLK1406 $614


Yes
V-4324-7 2*AF UGLK1474 $849
No 2*GM UGLK1474 $849
236
Yes 2*GK UGLK1474 $849
Yes 40 NF UGLK1406 $614
All prices are in US Dollars (USD)

No SV UGVL Pg # 21-12
V-4332 85
Yes SVK UGVL Pg # 21-13
No AM UGLK1406 $614
86
Yes AF UGLK1406 $614
No GM UGLK1406 $614
173 GK UGLK1406 $614
V-5254-(4, 5, 6, 12) Yes
2*AF UGLK1474 $849
No 2*GM UGLK1474 $849
236
Yes 2*GK UGLK1474 $849
Yes 40 NF UGLK1406 $614
No AM UGLK1406 $614
86
Yes AF UGLK1406 $614
No 173 GM UGLK1406 $614
GK UGLK1406 $614
V-5464-(3, 4, 12) Yes 173
2*AF UGLK1474 $849
No 2*GM UGLK1474 $849
236
Yes 2*GK UGLK1474 $849
Yes 40 NF UGLK1406 $614

All close-off pressures listed are approximate and actual close-off pressures are based on valve condition and application.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

21-23
Johnson Controls
V-54, V-58, VG7, V-52, VB-37, VB-39, VB-43 Series Valves
Linkage/Actuator Selection Guide

Belimo Belimo Linkage


Valve Body Model Size Fail-Safe Close-Off (psi)
Actuator Series Linkage List Price
Yes 86 AF UGLK1406 $614
No GM UGLK1406 $614
173 GK UGLK1406 $614
Yes
V-5844-(4, 5, 6, 12) 2*AF UGLK1474 $849
No 2*GM UGLK1474 $849
236
Yes 2*GK UGLK1474 $849
Yes 40 NF UGLK1406 $614
2” No SV UGVL Pg # 21-12
VG7000 Series 85
Yes SVK UGVL Pg # 21-13
Yes 86 AF UGLK1422 $614
No GM UGLK1422 $614
173
Yes GK UGLK1422 $614
VG7XXX-ST *Threaded Stem Only
Yes 153 AF UGLK1422 $614
Yes 40 NF UGLK1422 $614
Yes 14 LF UGLK1420 $557
No RV FGVL Pg # 21-12
75 AVK FGVL Pg # 21-13
Yes
2*AF UGLK1478 $849
V-5210-4595
Yes 38 AF UGLK1412 $614
No RV FGVL Pg # 21-12
136
Yes 2*GK UGLK1478 $849
No RV FGVL Pg # 21-12
110
Yes AVK FGVL Pg # 21-13
V-5252-(2, 4, 5, 6, 7, 8, 32, 33)
No EV FGVL Pg # 21-12
52
Yes AF UGLK1404 $614
Yes 211 2*GK UGLK1472 $854
V-5252-(4, 5, 6, 7, 8, 32, 33)
Yes 110 2*AF UGLK1472 $854
No RV FGVL Pg # 21-12
75 AVK FGVL Pg # 21-13
Yes
2*AF UGLK1478 $849
V-5410-4595
Yes 38 AF UGLK1412 $614
No RV FGVL Pg # 21-12
136
Yes 2*GK UGLK1478 $849
RETROFIT SOLUTIONS

No RV FGVL Pg # 21-12
211
Yes 2*GK UGLK1472 $854
No RV FGVL Pg # 21-12
V-5462-(6, 7, 34) 110 AVK FGVL Pg # 21-13

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


Yes
2*AF UGLK1472 $854
No EV FGVL Pg # 21-12
52
Yes AF UGLK1404 $614
2½”
No RV FGVL Pg # 21-12
211
Yes 2*GK UGLK1472 $854

All prices are in US Dollars (USD)


No RV FGVL Pg # 21-12
V-5842-(7, 8, 31) 110 AVK FGVL Pg # 21-13
Yes
2*AF UGLK1472 $854
No EV FGVL Pg # 21-12
52
Yes AF UGLK1404 $614
Yes 211 2*GK UGLK1472 $854
No 200 RV FGVL Pg # 21-12
Yes 120 AVK FGVL Pg # 21-13
VB-3752-19
Yes 110 2*AF UGLK1472 $854
No 75 EV FGVL Pg # 21-12
Yes 52 AF UGLK1404 $614
Yes 211 2*GK UGLK1472 $854
No 110 RV FGVL Pg # 21-12
AVK FGVL Pg # 21-13
VB-3970-11 Yes 110
2*AF UGLK1472 $854
No EV FGVL Pg # 21-12
52
Yes AF UGLK1404 $614
Yes 211 2*GK UGLK1472 $854
VB-4322-9
No 110 RV FGVL Pg # 21-12
AVK FGVL Pg # 21-13
Yes 110
2*AF UGLK1472 $854
VB-4322-9
No EV FGVL Pg # 21-12
52
Yes AF UGLK1404 $614

All close-off pressures listed are approximate and actual close-off pressures are based on valve condition and application.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

21-24
Johnson Controls
VG22, VG24, VG28, V-52, V-54 Series Valves
Linkage/Actuator Selection Guide

Belimo Belimo Linkage


Valve Body Model Size Fail-Safe Close-Off (psi)
Actuator Series Linkage List Price
No 211 RV FGVL Pg # 21-12
No EV FGVL Pg # 21-12
110
Yes AVK FGVL Pg # 21-13
VG2231 TM
Yes 211 2*GK UGLK1472 $854
Yes 110 2*AF UGLK1472 $854
Yes 52 AF UGLK1404 $614
No 211 RV FGVL Pg # 21-12
No EV FGVL Pg # 21-12
110
Yes AVK FGVL Pg # 21-13
VG2431 TM 2½”
Yes 211 2*GK UGLK1472 $854
Yes 110 2*AF UGLK1472 $854
Yes 52 AF UGLK1404 $614
No 211 RV FGVL Pg # 21-12
No EV FGVL Pg # 21-12
110
Yes AVK FGVL Pg # 21-13
VG2831 TM
Yes 211 2*GK UGLK1472 $854
Yes 110 2*AF UGLK1472 $854
Yes 52 AF UGLK1404 $614
No RV FGVL Pg # 21-12
93
Yes 2*GK UGLK1478 $849
No EV FGVL Pg # 21-12
V-5210-4596
52 AVK FGVL Pg # 21-13
Yes
2*AF UGLK1478 $849
Yes 26 AF UGLK1412 $614
No RV FGVL Pg # 21-12
93
Yes 2*GK UGLK1476 $849
No EV FGVL Pg # 21-12
V-5252-(12, 13, 35)
52 AVK FGVL Pg # 21-13
Yes
2*AF UGLK1476 $849
Yes 26 AF UGLK1410 $614
Yes 77 2*AF UGLK1472 $854
Yes 38 AF UGLK1404 $614
Yes 136 2*GK UGLK1472 $854

RETROFIT SOLUTIONS
V-5252-(9, 10, 11, 34)
No 93 RV FGVL Pg # 21-12
No EV FGVL Pg # 21-12
52
Yes AVK FGVL Pg # 21-13
No RV FGVL Pg # 21-12
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

93
Yes 2*GK UGLK1478 $849
No EV FGVL Pg # 21-12
V-5410-4596 3”
52 AVK FGVL Pg # 21-13
Yes
2*AF UGLK1478 $849
Yes 26 AF UGLK1412 $614
All prices are in US Dollars (USD)

No RV FGVL Pg # 21-12
93
Yes 2*GK UGLK1478 $849
No EV FGVL Pg # 21-12
V-5462-10
52 AVK FGVL Pg # 21-13
Yes
2*AF UGLK1478 $849
Yes 26 AF UGLK1412 $614
No RV FGVL Pg # 21-12
93
Yes 2*GK UGLK1476 $849
No EV FGVL Pg # 21-12
V-5462-35
52 AVK FGVL Pg # 21-13
Yes
2*AF UGLK1476 $849
Yes 26 AF UGLK1410 $614
No RV FGVL Pg # 21-12
93
Yes 2*GK UGLK1478 $849
No EV FGVL Pg # 21-12
V-5462-36
52 AVK FGVL Pg # 21-13
Yes
2*AF UGLK1478 $849
Yes 26 AF UGLK1412 $614

All close-off pressures listed are approximate and actual close-off pressures are based on valve condition and application.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

21-25
Johnson Controls
V-54, V-58, VB-37, VB-39, VB-43 Series Valves
Linkage/Actuator Selection Guide

Belimo Belimo Linkage


Valve Body Model Size Fail-Safe Close-Off (psi)
Actuator Series Linkage List Price
No RV FGVL Pg # 21-12
93
Yes 2*GK UGLK1476 $849
No EV FGVL Pg # 21-12
V-5462-8
52 AVK FGVL Pg # 21-13
Yes
2*AF UGLK1476 $849
Yes 26 AF UGLK1410 $614
No RV FGVL Pg # 21-12
93
Yes 2*GK UGLK1476 $849
No EV FGVL Pg # 21-12
V-5462-9
52 AVK FGVL Pg # 21-13
Yes
2*AF UGLK1476 $849
Yes 26 AF UGLK1410 $614
No RV FGVL Pg # 21-12
93
Yes 2*GK UGLK1476 $849
No EV FGVL Pg # 21-12
V-5842-10
52 AVK FGVL Pg # 21-13
Yes
2*AF UGLK1476 $849
Yes 26 AF UGLK1410 $614
No RV FGVL Pg # 21-12
93
Yes 2*GK UGLK1478 $849
No EV FGVL Pg # 21-12
V-5842-17
52 AVK FGVL Pg # 21-13
Yes
2*AF UGLK1478 $849
Yes 26 AF UGLK1412 $614
No RV FGVL Pg # 21-12
93
Yes 2*GK UGLK1478 $849
No EV FGVL Pg # 21-12
V-5842-18
52 AVK FGVL Pg # 21-13
Yes
2*AF UGLK1478 $849
Yes 26 AF UGLK1412 $614
No RV FGVL Pg # 21-12
93
Yes 2*GK UGLK1476 $849
No EV FGVL Pg # 21-12
RETROFIT SOLUTIONS

V-5842-32 3”
52 AVK FGVL Pg # 21-13
Yes
2*AF UGLK1476 $849
Yes 26 AF UGLK1410 $614
No RV FGVL Pg # 21-12

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


93
Yes 2*GK UGLK1478 $849
No EV FGVL Pg # 21-12
V-5842-33
52 AVK FGVL Pg # 21-13
Yes
2*AF UGLK1478 $849
Yes 26 AF UGLK1412 $614

All prices are in US Dollars (USD)


No RV FGVL Pg # 21-12
93
Yes 2*GK UGLK1476 $849
No EV FGVL Pg # 21-12
V-5842-9
52 AVK FGVL Pg # 21-13
Yes
2*AF UGLK1476 $849
Yes 26 AF UGLK1410 $614
No RV FGVL Pg # 21-12
93
Yes 2*GK UGLK1476 $849
No 70 EV FGVL Pg # 21-12
VB-3752-22
Yes 60 AVK FGVL Pg # 21-13
Yes 52 2*AF UGLK1476 $849
Yes 26 AF UGLK1410 $614
No RV FGVL Pg # 21-12
93
Yes 2*GK UGLK1476 $849
No EV FGVL Pg # 21-12
VB-3970-14
52 AVK FGVL Pg # 21-13
Yes
2*AF UGLK1476 $849
Yes 26 AF UGLK1410 $614
No RV FGVL Pg # 21-12
93
Yes 2*GK UGLK1476 $849
No EV FGVL Pg # 21-12
VB-4322-11
52 AVK FGVL Pg # 21-13
Yes
2*AF UGLK1476 $849
Yes 26 AF UGLK1410 $614

All close-off pressures listed are approximate and actual close-off pressures are based on valve condition and application.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

21-26
Johnson Controls
VG22, VG24, VG28, V-52, V-54 Series Valves
Linkage/Actuator Selection Guide

Belimo Belimo Linkage


Valve Body Model Size Fail-Safe Close-Off (psi)
Actuator Series Linkage List Price
No 93 RV FGVL Pg # 21-12
No EV FGVL Pg # 21-12
52
Yes AVK FGVL Pg # 21-13
VG2231 UM
Yes 93 2*GK UGLK1476 $849
Yes 52 2*AF UGLK1476 $849
Yes 26 AF UGLK1410 $614
No 93 RV FGVL Pg # 21-12
No EV FGVL Pg # 21-12
52
Yes AVK FGVL Pg # 21-13
VG2231 UN
Yes 93 2*GK UGLK1478 $849
Yes 52 2*AF UGLK1478 $849
Yes 26 AF UGLK1412 $614
No 93 RV FGVL Pg # 21-12
No EV FGVL Pg # 21-12
52
Yes AVK FGVL Pg # 21-13
VG2431 UM
Yes 93 2*GK UGLK1476 $849
Yes 52 2*AF UGLK1476 $849
Yes 26 AF UGLK1410 $614
3”
No 93 RV FGVL Pg # 21-12
No EV FGVL Pg # 21-12
52
Yes AVK FGVL Pg # 21-13
VG2431 UN
Yes 93 2*GK UGLK1478 $849
Yes 52 2*AF UGLK1478 $849
Yes 26 AF UGLK1412 $614
No 93 RV FGVL Pg # 21-12
No EV FGVL Pg # 21-12
52
Yes AVK FGVL Pg # 21-13
VG2831 UM
Yes 93 2*GK UGLK1476 $849
Yes 52 2*AF UGLK1476 $849
Yes 26 AF UGLK1410 $614
No 93 RV FGVL Pg # 21-12
No EV FGVL Pg # 21-12
52
Yes AVK FGVL Pg # 21-13

RETROFIT SOLUTIONS
VG2831 UN
Yes 93 2*GK UGLK1478 $849
Yes 52 2*AF UGLK1478 $849
Yes 26 AF UGLK1412 $614
No RV FGVL Pg # 21-12
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

52
Yes 2*GK UGLK1478 $849
No EV FGVL Pg # 21-12
V-5210-4597
26 AVK FGVL Pg # 21-13
Yes
2*AF UGLK1478 $849
Yes 14 AF UGLK1412 $614
All prices are in US Dollars (USD)

No RV FGVL Pg # 21-12
52
Yes 2*GK UGLK1476 $849
No EV FGVL Pg # 21-12
V-5252-(14, 36)
26 AVK FGVL Pg # 21-13
Yes
2*AF UGLK1476 $849
Yes 14 AF UGLK1410 $614
No RV FGVL Pg # 21-12
52
Yes 2*GK UGLK1478 $849
No EV FGVL Pg # 21-12
V-5252-(15, 16, 37) 4”
26 AVK FGVL Pg # 21-13
Yes
2*AF UGLK1478 $849
Yes 14 AF UGLK1412 $614
No 52 RV FGVL Pg # 21-12
Yes 2*GK UGLK1478 $849
No EV FGVL Pg # 21-12
V-5410-4597
26 AVK FGVL Pg # 21-13
Yes
2*AF UGLK1478 $849
Yes 14 AF UGLK1412 $614
No RV FGVL Pg # 21-12
52
Yes 2*GK UGLK1476 $849
No EV FGVL Pg # 21-12
V-5462-11
26 AVK FGVL Pg # 21-13
Yes
2*AF UGLK1476 $849
Yes 14 AF UGLK1410 $614

All close-off pressures listed are approximate and actual close-off pressures are based on valve condition and application.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

21-27
Johnson Controls
V-54, V-58, VB-37, VB-39, VB-43 Series Valves
Linkage/Actuator Selection Guide

Belimo Belimo Linkage


Valve Body Model Size Fail-Safe Close-Off (psi)
Actuator Series Linkage List Price
No RV FGVL Pg # 21-12
52
Yes 2*GK UGLK1476 $849
No EV FGVL Pg # 21-12
V-5462-12
26 AVK FGVL Pg # 21-13
Yes
2*AF UGLK1476 $849
Yes 14 AF UGLK1410 $614
No RV FGVL Pg # 21-12
52
Yes 2*GK UGLK1478 $849
No EV FGVL Pg # 21-12
V-5462-13
26 AVK FGVL Pg # 21-13
Yes
2*AF UGLK1478 $849
Yes 14 AF UGLK1412 $614
No RV FGVL Pg # 21-12
52
Yes 2*GK UGLK1478 $849
No EV FGVL Pg # 21-12
V-5462-14
26 AVK FGVL Pg # 21-13
Yes
2*AF UGLK1478 $849
Yes 14 AF UGLK1412 $614
No RV FGVL Pg # 21-12
52
Yes 2*GK UGLK1476 $849
No EV FGVL Pg # 21-12
V-5462-37
26 AVK FGVL Pg # 21-13
Yes
2*AF UGLK1476 $849
Yes 14 AF UGLK1410 $614
No RV FGVL Pg # 21-12
52
Yes 2*GK UGLK1478 $849
No EV FGVL Pg # 21-12
V-5462-38
26 AVK FGVL Pg # 21-13
Yes
2*AF UGLK1478 $849
Yes 14 AF UGLK1412 $614
No RV FGVL Pg # 21-12
52
Yes 2*GK UGLK1478 $849
No EV FGVL Pg # 21-12
RETROFIT SOLUTIONS

V-5842-11 4”
26 AVK FGVL Pg # 21-13
Yes
2*AF UGLK1478 $849
Yes 14 AF UGLK1412 $614
No RV FGVL Pg # 21-12

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


52
Yes 2*GK UGLK1478 $849
No EV FGVL Pg # 21-12
V-5842-12
26 AVK FGVL Pg # 21-13
Yes
2*AF UGLK1478 $849
Yes 14 AF UGLK1412 $614

All prices are in US Dollars (USD)


No RV FGVL Pg # 21-12
52
Yes 2*GK UGLK1478 $849
No EV FGVL Pg # 21-12
V-5842-34
26 AVK FGVL Pg # 21-13
Yes
2*AF UGLK1478 $849
Yes 14 AF UGLK1412 $614
No RV FGVL Pg # 21-12
52
Yes 2*GK UGLK1476 $849
No 40 EV FGVL Pg # 21-12
VB-3752-25
Yes 30 AVK FGVL Pg # 21-13
Yes 26 2*AF UGLK1476 $849
Yes 14 AF UGLK1410 $614
No RV FGVL Pg # 21-12
52
Yes 2*GK UGLK1476 $849
No EV FGVL Pg # 21-12
VB-3970-17
26 AVK FGVL Pg # 21-13
Yes
2*AF UGLK1476 $849
Yes 14 AF UGLK1410 $614
No RV FGVL Pg # 21-12
52
Yes 2*GK UGLK1476 $849
No EV FGVL Pg # 21-12
VB-4322-13
26 AVK FGVL Pg # 21-13
Yes
2*AF UGLK1476 $849
Yes 14 AF UGLK1410 $614

All close-off pressures listed are approximate and actual close-off pressures are based on valve condition and application.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

21-28
Johnson Controls
VG22, VG24, VG28, V-52, V-54 Series Valves
Linkage/Actuator Selection Guide

Belimo Belimo Linkage


Valve Body Model Size Fail-Safe Close-Off (psi)
Actuator Series Linkage List Price
No 52 RV FGVL Pg # 21-12
No EV FGVL Pg # 21-12
26
Yes AVK FGVL Pg # 21-13
VG2231 VM
Yes 52 2*GK UGLK1476 $849
Yes 26 2*AF UGLK1476 $849
Yes 14 AF UGLK1410 $614
No 52 RV FGVL Pg # 21-12
No EV FGVL Pg # 21-12
26
Yes AVK FGVL Pg # 21-13
VG2231 VN
Yes 52 2*GK UGLK1478 $849
Yes 26 2*AF UGLK1478 $849
Yes 14 AF UGLK1412 $614
No 52 RV FGVL Pg # 21-12
No EV FGVL Pg # 21-12
26
Yes AVK FGVL Pg # 21-13
VG2431 VM
Yes 52 2*GK UGLK1476 $849
Yes 26 2*AF UGLK1476 $849
Yes 14 AF UGLK1410 $614
4”
No 52 RV FGVL Pg # 21-12
No EV FGVL Pg # 21-12
26
Yes AVK FGVL Pg # 21-13
VG2431 VN
Yes 52 2*GK UGLK1478 $849
Yes 26 2*AF UGLK1478 $849
Yes 14 AF UGLK1412 $614
No 52 RV FGVL Pg # 21-12
No EV FGVL Pg # 21-12
26
Yes AVK FGVL Pg # 21-13
VG2831 VM
Yes 52 2*GK UGLK1476 $849
Yes 26 2*AF UGLK1476 $849
Yes 14 AF UGLK1410 $614
No 52 RV FGVL Pg # 21-12
No EV FGVL Pg # 21-12
26
Yes AVK FGVL Pg # 21-13

RETROFIT SOLUTIONS
VG2831 VN
Yes 52 2*GK UGLK1478 $849
Yes 26 2*AF UGLK1478 $849
Yes 14 AF UGLK1412 $614
No RV FGVL Pg # 21-12
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

22
Yes 2*GK UGLK1480 $854
No EV FGVL Pg # 21-12
V-5252-17
14 GK UGLK1414 $618
Yes
2*AF UGLK1480 $854
Yes 10 AF UGLK1414 $618
All prices are in US Dollars (USD)

No RV FGVL Pg # 21-12
22
Yes 2*GK UGLK1480 $854
No EV FGVL Pg # 21-12
V-5252-18
14 GK UGLK1414 $618
Yes
2*AF UGLK1480 $854
Yes 10 AF UGLK1414 $618
No RV FGVL Pg # 21-12
22
Yes 2*GK UGLK1480 $854
No EV FGVL Pg # 21-12
V-5252-38 5”
14 GK UGLK1414 $618
Yes
2*AF UGLK1480 $854
Yes 10 AF UGLK1414 $618
No RV FGVL Pg # 21-12
22
Yes 2*GK UGLK1480 $854
No EV FGVL Pg # 21-12
V-5462-15
14 GK UGLK1414 $618
Yes
2*AF UGLK1480 $854
Yes 10 AF UGLK1414 $618
No RV FGVL Pg # 21-12
22
Yes 2*GK UGLK1480 $854
No EV FGVL Pg # 21-12
V-5462-16
14 GK UGLK1414 $618
Yes
2*AF UGLK1480 $854
Yes 10 AF UGLK1414 $618

All close-off pressures listed are approximate and actual close-off pressures are based on valve condition and application.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

21-29
Johnson Controls
V-54, V-58, VB-37, VB-39, VB-43, VG22, VG24, VG28, V-52 Series Valves
Linkage/Actuator Selection Guide

Belimo Belimo Linkage


Valve Body Model Size Fail-Safe Close-Off (psi)
Actuator Series Linkage List Price
No RV FGVL Pg # 21-12
22
Yes 2*GK UGLK1480 $854
No EV FGVL Pg # 21-12
V-5462-39
14 GK UGLK1414 $618
Yes
2*AF UGLK1480 $854
Yes 10 AF UGLK1414 $618
No RV FGVL Pg # 21-12
22
Yes 2*GK UGLK1480 $854
No EV FGVL Pg # 21-12
V-5842-13
14 GK UGLK1414 $618
Yes
2*AF UGLK1480 $854
Yes 10 AF UGLK1414 $618
No RV FGVL Pg # 21-12
22
Yes 2*GK UGLK1480 $854
No EV FGVL Pg # 21-12
V-5842-14
14 GK UGLK1414 $618
Yes
2*AF UGLK1480 $854
Yes 10 AF UGLK1414 $618
No RV FGVL Pg # 21-12
22
Yes 2*GK UGLK1480 $854
No EV FGVL Pg # 21-12
V-5842-35
14 GK UGLK1414 $618
Yes
2*AF UGLK1480 $854
Yes 10 AF UGLK1414 $618
No RV FGVL Pg # 21-12
22
Yes 2*GK UGLK1480 $854
No EV FGVL Pg # 21-12
VB-3752-28
14 GK UGLK1414 $618
Yes
2*AF UGLK1480 $854
Yes 10 AF UGLK1414 $618
5”
No RV FGVL Pg # 21-12
22
Yes 2*GK UGLK1480 $854
No EV FGVL Pg # 21-12
RETROFIT SOLUTIONS

VB-3970-20
14 GK UGLK1414 $618
Yes
2*AF UGLK1480 $854
Yes 10 AF UGLK1414 $618
No RV FGVL Pg # 21-12

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


22
Yes 2*GK UGLK1480 $854
No EV FGVL Pg # 21-12
VB-4322-19
14 GK UGLK1414 $618
Yes
2*AF UGLK1480 $854
Yes 10 AF UGLK1414 $618

All prices are in US Dollars (USD)


No 22 RV FGVL Pg # 21-12
No 14 EV FGVL Pg # 21-12
Yes 22 2*GK UGLK1480 $854
VG2231 WN
GK UGLK1414 $618
Yes 14
2*AF UGLK1480 $854
Yes 10 AF UGLK1414 $618
No 22 RV FGVL Pg # 21-12
No 14 EV FGVL Pg # 21-12
Yes 22 2*GK UGLK1480 $854
VG2431 WN
GK UGLK1414 $618
Yes 14
2*AF UGLK1480 $854
Yes 10 AF UGLK1414 $618
No 22 RV FGVL Pg # 21-12
No 14 EV FGVL Pg # 21-12
Yes 22 2*GK UGLK1480 $854
VG2831 WN
GK UGLK1414 $618
Yes 14
2*AF UGLK1480 $854
Yes 10 AF UGLK1414 $618
No RV FGVL Pg # 21-12
22
Yes 2*GK UGLK1480 $854
V-5252-19 6” No EV FGVL Pg # 21-12
10 GK UGLK1414 $618
Yes
2*AF UGLK1480 $854

All close-off pressures listed are approximate and actual close-off pressures are based on valve condition and application.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

21-30
Johnson Controls
V-52, V-54, V-58, VB-37, VB-39, VB-43, VG22, VG24, VG28 Series Valves
Linkage/Actuator Selection Guide

Belimo Belimo Linkage


Valve Body Model Size Fail-Safe Close-Off (psi)
Actuator Series Linkage List Price
No RV FGVL Pg # 21-12
22
Yes 2*GK UGLK1480 $854
V-5252-39 No EV FGVL Pg # 21-12
10 GK UGLK1414 $618
Yes
2*AF UGLK1480 $854
No RV FGVL Pg # 21-12
22
Yes 2*GK UGLK1480 $854
V-5462-17 No EV FGVL Pg # 21-12
10 GK UGLK1414 $618
Yes
2*AF UGLK1480 $854
No RV FGVL Pg # 21-12
22
Yes 2*GK UGLK1480 $854
V-5462-18 No EV FGVL Pg # 21-12
10 GK UGLK1414 $618
Yes
2*AF UGLK1480 $854
No RV FGVL Pg # 21-12
22
Yes 2*GK UGLK1480 $854
V-5462-40 No EV FGVL Pg # 21-12
10 GK UGLK1414 $618
Yes
2*AF UGLK1480 $854
No RV FGVL Pg # 21-12
22
Yes 2*GK UGLK1480 $854
V-5842-15 No EV FGVL Pg # 21-12
10 GK UGLK1414 $618
Yes
2*AF UGLK1480 $854
No RV FGVL Pg # 21-12
22
Yes 2*GK UGLK1480 $854
V-5842-16 No EV FGVL Pg # 21-12
10 GK UGLK1414 $618
Yes
2*AF UGLK1480 $854
No RV FGVL Pg # 21-12
22
Yes 2*GK UGLK1480 $854
V-5842-36 6” No EV FGVL Pg # 21-12

RETROFIT SOLUTIONS
10 GK UGLK1414 $618
Yes
2*AF UGLK1480 $854
No RV FGVL Pg # 21-12
22
Yes 2*GK UGLK1480 $854
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

VB-3752-31 No EV FGVL Pg # 21-12


10 GK UGLK1414 $618
Yes
2*AF UGLK1480 $854
No RV FGVL Pg # 21-12
22
Yes 2*GK UGLK1480 $854
All prices are in US Dollars (USD)

VB-3970-23 No EV FGVL Pg # 21-12


10 GK UGLK1414 $618
Yes
2*AF UGLK1480 $854
No RV FGVL Pg # 21-12
22
Yes 2*GK UGLK1480 $854
VB-4322-18 No EV FGVL Pg # 21-12
10 GK UGLK1414 $618
Yes
2*AF UGLK1480 $854
No 22 RV FGVL Pg # 21-12
No 10 EV FGVL Pg # 21-12
VG2231 YN Yes 22 2*GK UGLK1480 $854
GK UGLK1414 $618
Yes 10
2*AF UGLK1480 $854
No 22 RV FGVL Pg # 21-12
No 10 EV FGVL Pg # 21-12
VG2431 YN Yes 22 2*GK UGLK1480 $854
GK UGLK1414 $618
Yes 10
2*AF UGLK1480 $854
No 22 RV FGVL Pg # 21-12
No 10 EV FGVL Pg # 21-12
VG2831 YN Yes 22 2*GK UGLK1480 $854
GK UGLK1414 $618
Yes 10
2*AF UGLK1480 $854

All close-off pressures listed are approximate and actual close-off pressures are based on valve condition and application.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

21-31
Robertshaw Siebe\Invensys\Barber Colman\Schneider
V6600, V6700, V6800 Series Valves Belimo USA G2, Belimo USA G3, VB30.., VB7.., VB80.., VB9.. Series Valves
Linkage/Actuator Selection Guide Linkage/Actuator Selection Guide

Belimo Belimo Linkage


Valve Body Model Size Fail-Safe Close-Off (psi)
Actuator Series Linkage List Price
No LV UGVL Pg # 21-12
V6600 236
Yes LVK UGVL Pg # 21-13
½”
No LV UGVL Pg # 21-12
V6700 236
Yes LVK UGVL Pg # 21-13
No LV UGVL Pg # 21-12
V6600 211
Yes LVK UGVL Pg # 21-13
¾”
No LV UGVL Pg # 21-12
V6700, V6800 211
Yes LVK UGVL Pg # 21-13
No LV UGVL Pg # 21-12
93
Yes LVK UGVL Pg # 21-13
V6600
No SV UGVL Pg # 21-12
236
Yes SVK UGVL Pg # 21-13
1”
No LV UGVL Pg # 21-12
93
Yes LVK UGVL Pg # 21-13
V6700
No SV UGVL Pg # 21-12
236
Yes SVK UGVL Pg # 21-13
No SV UGVL Pg # 21-12
V6600 236
Yes SVK UGVL Pg # 21-13
1¼”
No SV UGVL Pg # 21-12
V6700 236
Yes SVK UGVL Pg # 21-13
No SV UGVL Pg # 21-12
V6600 160
Yes SVK UGVL Pg # 21-13
1½”
No SV UGVL Pg # 21-12
V6700 160
Yes SVK UGVL Pg # 21-13
No SV UGVL Pg # 21-12
V6600 85
Yes SVK UGVL Pg # 21-13
2”
No SV UGVL Pg # 21-12
V6700 85
Yes SVK UGVL Pg # 21-13
SIEBE\INVENSYS\BARBER COLMAN\SCHNEIDER
Yes 250 LF UGLK1150** $409
Belimo USA G2/G2S Series
No LV SGVL Pg # 21-12
(OLD = pre April 2018) 250
Yes LVK SGVL Pg # 21-13
Yes 250 LF UGLK1150** $409
RETROFIT SOLUTIONS

Belimo USA G3 Series


No LV SGVL Pg # 21-12
(OLD = pre April 2018) 250
Yes LVK SGVL Pg # 21-13
No LM UGLK1002 $550
VB304X-0-1-4 236 LF UGLK1002 $550
Yes

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


AF UGLK1004 $609
No LV SGVL Pg # 21-12
VB7000 Series 236
Yes LVK SGVL Pg # 21-13
VB7XXX-0-4-1 Yes 236 LF UGLK1150** $409
½”
VB7XXX-0-4-2 Yes 236 LF UGLK1150** $409

All prices are in US Dollars (USD)


VB7XXX-0-4-3 Yes 236 LF UGLK1150** $409
VB7XXX-0-4-4 Yes 236 LF UGLK1150** $409
No LM UGLK1002 $550
VB804X-0-1-4 236 LF UGLK1002 $550
Yes
AF UGLK1004 $609
No LV SGVL Pg # 21-12
VB9000 Series 236
Yes LVK SGVL Pg # 21-13
VB9XXX-0-4-1 Yes 236 LF UGLK1150** $409
VB9XXX-0-4-2 Yes 236 LF UGLK1150** $409
VB9XXX-0-4-3 Yes 236 LF UGLK1150** $409
VB9XXX-0-4-4 Yes 236 LF UGLK1150** $409
Yes 215 LF UGLK1150** $409
Belimo USA G2/G2S Series
No LV SGVL Pg # 21-12
(OLD = pre April 2018) 250
Yes LVK SGVL Pg # 21-13
Yes 215 LF UGLK1150** $409
Belimo USA G3 Series
No LV SGVL Pg # 21-12
(OLD = pre April 2018) 250
Yes LVK SGVL Pg # 21-13
¾”
No 236 NM UGLK1002 $550
VB304X-0-1-7
Yes 110 LF UGLK1002 $550
No LV SGVL Pg # 21-12
VB7000 Series 211
Yes LVK SGVL Pg # 21-13
VB7XXX-0-4-5 Yes 211 LF UGLK1150** $409
VB7XXX-0-4-6 Yes 211 LF UGLK1150** $409
**Not compatible with the new Belimo G2xxB-x, G2xxS-x, and G3xxB-x globe valves.
All close-off pressures listed are approximate and actual close-off pressures are based on valve condition and application.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

21-32
Siebe\Invensys\Barber Colman\Schneider
VB80.., VB9.., Belimo USA G2, Belimo USA G3, VB30.., VB7.. Series Valves
Linkage/Actuator Selection Guide

Belimo Belimo Linkage


Valve Body Model Size Fail-Safe Close-Off (psi)
Actuator Series Linkage List Price
No 236 NM UGLK1002 $550
VB804X-0-1-7
Yes 110 LF UGLK1002 $550
No LV SGVL Pg # 21-12
VB9000 Series ¾” 211
Yes LVK SGVL Pg # 21-13
VB9XXX-0-4-5 Yes 211 LF UGLK1150** $409
VB9XXX-0-4-6 Yes 211 LF UGLK1150** $409
Yes 95 LF UGLK1150** $409
Belimo USA G2/G2S Series Yes 250 AF UGLK1000** $613
(OLD = pre April 2018) No 250 SV SGVL Pg # 21-12
Yes 236 SVK SGVL Pg # 21-13
Yes 95 LF UGLK1150** $409
Belimo USA G3 Series Yes 250 AF UGLK1000** $613
(OLD = pre April 2018) No 250 SV SGVL Pg # 21-12
Yes 236 SVK SGVL Pg # 21-13
No 173 NM UGLK1002 $550
No AM UGLK1004 $609
VB304X-0-1-8 236
Yes AF UGLK1004 $609
Yes 65 LF UGLK1002 $550
No SV SGVL Pg # 21-12
93
Yes SVK SGVL Pg # 21-13
VB7000 Series
No SV SGVL Pg # 21-12
1” 236
Yes SVK SGVL Pg # 21-13
VB7XXX-0-4-(7, 8) Yes 236 AF UGLK1000** $613
VB7XXX-0-4-7 Yes 93 LF UGLK1150** $409
VB7XXX-0-4-8 Yes 93 LF UGLK1150** $409
No 173 NM UGLK1002 $550
No AM UGLK1004 $609
VB804X-0-1-8 236
Yes AF UGLK1004 $609
Yes 65 LF UGLK1002 $550
No SV SGVL Pg # 21-12
93
Yes LVK SGVL Pg # 21-13
VB9000 Series
No SV SGVL Pg # 21-12
236
Yes SVK SGVL Pg # 21-13

RETROFIT SOLUTIONS
VB9XXX-0-4-(7, 8) Yes 236 AF UGLK1000** $613
VB9XXX-0-4-7 Yes 93 LF UGLK1150** $409
VB9XXX-0-4-8 Yes 93 LF UGLK1150** $409
Yes 61 LF UGLK1150** $409
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

Belimo USA G2/G2S Series Yes 250 AF UGLK1000** $613


(OLD = pre April 2018) Yes 236 SVK SGVL Pg # 21-13
No 235 SV SGVL Pg # 21-12
Yes 61 LF UGLK1150** $409
Belimo USA G3 Series Yes 250 AF UGLK1000** $613
All prices are in US Dollars (USD)

(OLD = pre April 2018) Yes 236 SVK SGVL Pg # 21-13


No 235 SV SGVL Pg # 21-12
No AM UGLK1004 $609
221
Yes AF UGLK1004 $609
VB304X-0-1-9
No 110 NM UGLK1002 $550
Yes 40 LF UGLK1002 $550
1¼”
No SV SGVL Pg # 21-12
VB7000 Series 236
Yes SVK SGVL Pg # 21-13
Yes 236 AF UGLK1000** $613
VB7XXX-0-4-9
Yes 65 LF UGLK1150** $409
No AM UGLK1004 $609
221
Yes AF UGLK1004 $609
VB804X-0-1-9
No 110 NM UGLK1002 $550
Yes 40 LF UGLK1002 $550
No SV SGVL Pg # 21-12
VB9000 Series 236
Yes SVK SGVL Pg # 21-13
Yes 236 AF UGLK1000** $613
VB9XXX-0-4-9
Yes 65 LF UGLK1150** $409
Yes 217 AF UGLK1000** $613
Belimo USA G2/G2S Series
No SV SGVL Pg # 21-12
(OLD = pre April 2018) 160
Yes SVK SGVL Pg # 21-13
1½”
Yes 217 AF UGLK1000** $613
Belimo USA G3 Series
No SV SGVL Pg # 21-12
(OLD = pre April 2018) 160
Yes SVK SGVL Pg # 21-13

All close-off pressures listed are approximate and actual close-off pressures are based on valve condition and application. **Not compatible with the new Belimo G2xxB-x, G2xxS-x,
and G3xxB-x globe valves.
800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

21-33
Siebe\Invensys\Barber Colman\Schneider
VB30.., VB7.. VB80.., VB9.., Belimo USA G2, Belimo USA G3 Series Series Valves
Linkage/Actuator Selection Guide

Belimo Belimo Linkage


Valve Body Model Size Fail-Safe Close-Off (psi)
Actuator Series Linkage List Price
No 77 NM UGLK1002 $550
No AM UGLK1004 $609
153
Yes AF UGLK1004 $609
VB304X-0-1-10
No GM UGLK1004 $609
236
Yes GK UGLK1004 $609
Yes 26 LF UGLK1002 $550
No SV SGVL Pg # 21-12
VB7000 Series 160
Yes SVK SGVL Pg # 21-13
VB7XXX-0-4-10 Yes 211 AF UGLK1000** $613
No 77 NM UGLK1002 $550
No AM UGLK1004 $609
153
Yes AF UGLK1004 $609
VB804X-0-1-10
No GM UGLK1004 $609
236
Yes GK UGLK1004 $609
1½” Yes 26 LF UGLK1002 $550
Yes 79 AF UGLK1016 $609
No 2*GM UGLK1066 $840
236
Yes 2*GK UGLK1066 $840
VB9XXX-0-4-10 (Post ‘94)*
Yes 211 2*AF UGLK1066 $840
No GM UGLK1016 $609
160
Yes GK UGLK1016 $609
No 2*GM UGLK1064 $840
236
Yes 2*GK UGLK1064 $840
No GM UGLK1008 $609
211 GK UGLK1008 $609
VB9XXX-0-4-10 (Pre ‘94) Yes
2*AF UGLK1064 $840
AF UGLK1008 $609
Yes
110 SV UGVL Pg # 21-12
No SVK UGVL Pg # 21-13
Yes 122 AF UGLK1000** $613
Belimo USA G2/G2S Series
No 90 SV SGVL Pg # 21-12
(OLD = pre April 2018)
Yes 85 SVK SGVL Pg # 21-13
Yes 122 AF UGLK1000** $613
RETROFIT SOLUTIONS

Belimo USA G3 Series


No 90 SV SGVL Pg # 21-12
(OLD = pre April 2018)
Yes 85 SVK SGVL Pg # 21-13
No AM UGLK1004 $609
86
Yes AF UGLK1004 $609

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


No GM UGLK1004 $609
VB304X-0-1-11 173
Yes GK UGLK1004 $609
No 40 NM UGLK1002 $550
Yes 14 LF UGLK1002 $550
No SV SGVL Pg # 21-12
VB7000 Series 85

All prices are in US Dollars (USD)


Yes SVK SGVL Pg # 21-13
VB7XXX-0-4-11 Yes 120 AF UGLK1000** $613
No AM UGLK1004 $609
86
Yes AF UGLK1004 $609
2” No GM UGLK1004 $609
VB804X-0-1-11 173
Yes GK UGLK1004 $609
No 40 NM UGLK1002 $550
Yes 14 LF UGLK1002 $550
No GM UGLK1016 $609
89
Yes GK UGLK1016 $609
No 2*GM UGLK1066 $840
VB9XXX-0-4-11 (Post ‘94) 211
Yes 2*GK UGLK1066 $840
Yes 110 2*AF UGLK1066 $840
Yes 40 AF UGLK1016 $609
No 2*GM UGLK1064 $840
211
Yes 2*GK UGLK1064 $840
No GM UGLK1008 $609
110 GK UGLK1008 $609
VB9XXX-0-4-11 (Pre ‘94) Yes
2*AF UGLK1064 $840
52 AF UGLK1008 $609
Yes
SVK UGVL Pg # 21-13
110
No SV UGVL Pg # 21-12

**Not compatible with the new Belimo G2xxB-x, G2xxS-x, and G3xxB-x globe valves.

All close-off pressures listed are approximate and actual close-off pressures are based on valve condition and application. *Will also work with UGVL+SV+SGVL kit

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

21-34
Siebe\Invensys\Barber Colman\Schneider
VB30.., VB80.., VB9 Series Valves
Linkage/Actuator Selection Guide

Belimo Belimo Linkage


Valve Body Model Size Fail-Safe Close-Off (psi)
Actuator Series Linkage List Price
Yes 75 2*AF UGLK1072 $840
Yes 38 AF UGLK1006 $609
VB304X-0-2-12 2½”
No 2*GM UGLK1072 $840
136
Yes 2*GK UGLK1072 $840
No 90 RV FGVL Pg # 21-12
VB304X-0-2-12 Yes 80 AVK FGVL Pg # 21-13
No 45 EV FGVL Pg # 21-12
Yes 75 2*AF UGLK1072 $840
Yes 38 AF UGLK1006 $609
No 2*GM UGLK1072 $840
136
VB804X-0-2-12 Yes 2*GK UGLK1072 $840
No 90 RV FGVL Pg # 21-12
Yes 85 AVK FGVL Pg # 21-13
No 40 EV FGVL Pg # 21-12
No GM UGLK1010 $609
2½” 75 GK UGLK1010 $609
Yes
2*AF UGLK1070 $846
VB9XXX-0-4-12 No AM UGLK1010 $609
38
Yes AF UGLK1010 $609
No 2*GM UGLK1070 $846
136
Yes 2*GK UGLK1070 $846
Yes 75 2*AF UGLK1070 $846
Yes 38 AF UGLK1010 $609
Yes 136 2*GK UGLK1070 $846
VB9XXX-0-5-12
No 150 RV FGVL Pg # 21-12
No EV FGVL Pg # 21-12
80
Yes AVK FGVL Pg # 21-13
No 2*GM UGLK1072 $840
93
Yes 2*GK UGLK1072 $840
No 70 RV FGVL Pg # 21-12
VB304X-0-2-13 Yes 60 AVK FGVL Pg # 21-13
Yes 52 2*AF UGLK1072 $840
No 35 EV FGVL Pg # 21-12

RETROFIT SOLUTIONS
Yes 26 AF UGLK1006 $609
No 2*GM UGLK1072 $840
93
Yes 2*GK UGLK1072 $840
No 65 RV FGVL Pg # 21-12
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

VB804X-0-2-13 Yes 60 AVK FGVL Pg # 21-13


Yes 52 2*AF UGLK1072 $840
No 30 EV FGVL Pg # 21-12
3” Yes 26 AF UGLK1006 $609
No 2*GM UGLK1070 $846
93
All prices are in US Dollars (USD)

Yes 2*GK UGLK1070 $846


No GM UGLK1010 $609
VB9XXX-0-4-13 52 GK UGLK1010 $609
Yes
2*AF UGLK1070 $846
No AM UGLK1010 $609
26
Yes AF UGLK1010 $609
Yes 93 2*GK UGLK1070 $846
No 90 RV FGVL Pg # 21-12
Yes 52 2*AF UGLK1070 $846
VB9XXX-0-5-13
No EV FGVL Pg # 21-12
40
Yes AVK FGVL Pg # 21-13
Yes 26 AF UGLK1010 $609
No 2*GM UGLK1072 $840
52
Yes 2*GK UGLK1072 $840
No 35 RV FGVL Pg # 21-12
VB304X-0-2-14 Yes 30 AVK FGVL Pg # 21-13
Yes 26 2*AF UGLK1072 $840
4” No 20 EV FGVL Pg # 21-12
Yes 14 AF UGLK1006 $609
No 2*GM UGLK1072 $840
52
Yes 2*GK UGLK1072 $840
VB804X-0-2-14
No 45 RV FGVL Pg # 21-12
Yes 30 AVK FGVL Pg # 21-13

All close-off pressures listed are approximate and actual close-off pressures are based on valve condition and application.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

21-35
Siebe\Invensys\Barber Colman\Schneider Siemens\Landis\Powers
VB9.., VB30.., VB80.. Series Valves 591, 599, 656, 658 Series Valves
Linkage/Actuator Selection Guide Linkage/Actuator Selection Guide

Belimo Belimo Linkage


Valve Body Model Size Fail-Safe Close-Off (psi)
Actuator Series Linkage List Price
Yes 26 2*AF UGLK1072 $840
VB804X-0-2-14 No 20 EV FGVL Pg # 21-12
Yes 14 AF UGLK1006 $609
Yes 22 2*AF UGLK1074 $840
No 40 2*GM UGLK1074 $840
4”
Yes 40 2*GK UGLK1074 $840
VB9XXX-0-5-14 No 30 RV FGVL Pg # 21-12
Yes 25 AVK FGVL Pg # 21-13
No 15 EV FGVL Pg # 21-12
Yes 10 AF UGLK1012 $609
No 2*GM UGLK1076 $840
22
Yes 2*GK UGLK1076 $840
No 24 RV FGVL Pg # 21-12
VB304X-0-2-15
No 15 EV FGVL Pg # 21-12
Yes 14 2*AF UGLK1076 $840
Yes 10 AF UGLK1014 $609
5” Yes 22 2*GK UGLK1076 $840
No 20 RV FGVL Pg # 21-12
No 15 EV FGVL Pg # 21-12
VB804X-0-2-15
GK UGLK1014 $609
Yes 14
2*AF UGLK1076 $840
Yes 10 AF UGLK1014 $609
VB9XXX-0-5-15 No 20 RV FGVL Pg # 21-12
No 2*GM UGLK1076 $840
22
Yes 2*GK UGLK1076 $840
No 15 RV FGVL Pg # 21-12
VB304X-0-2-16
No 13 EV FGVL Pg # 21-12
AF UGLK1014 $609
Yes 10
2*AF UGLK1076 $840
6” Yes 22 2*GK UGLK1076 $840
No 22 RV FGVL Pg # 21-12
No 13 EV FGVL Pg # 21-12
VB804X-0-2-16
AF $609
RETROFIT SOLUTIONS

UGLK1014
Yes 10 GK $609
2*AF UGLK1076 $840
VB9XXX-0-5-16 No 15 RV FGVL Pg # 21-12
SIEMENS\LANDIS\POWERS

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


No LV UGVL Pg # 21-12
591 Series 236 LVK UGVL Pg # 21-13
Yes
NF UGLK1200 $614
No LV UGVL Pg # 21-12
599 Flowrite ½” 236 LVK UGVL Pg # 21-13
Yes

All prices are in US Dollars (USD)


NF UGLK1208 $614
No CM UGSL1200 $108
599 MZ/MT Series 10-120
Yes TF UGSL1200 $108
656, 658 Series Yes 236 LF UGLK1350 $405
Yes 236 NF UGLK1200 $614
591 Series No LV UGVL Pg # 21-12
211
Yes LVK UGVL Pg # 21-13
No AM UGLK1208 $614
236
Yes AF UGLK1208 $614
599 Flowrite ¾”
No LV UGVL Pg # 21-12
211
Yes LVK UGVL Pg # 21-13
No CM UGSL1200 $108
599 MZ/MT Series 10-120
Yes TF UGSL1200 $108
656, 658 Series Yes 211 LF UGLK1350 $405
SV UGVL Pg # 21-12
No
AM UGLK1200 $614
591 Series 1” 236
SVK UGVL Pg # 21-13
Yes
AF UGLK1200 $614

All close-off pressures listed are approximate and actual close-off pressures are based on valve condition and application.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

21-36
Siemens\Landis\Powers
599, 656, 658, 591 Series Valves
Linkage/Actuator Selection Guide

Belimo Belimo Linkage


Valve Body Model Size Fail-Safe Close-Off (psi)
Actuator Series Linkage List Price
Yes 173 NF UGLK1208 $614
SV UGVL Pg # 21-12
No
599 Flowrite AM UGLK1208 $614
236
SVK UGVL Pg # 21-13
Yes
AF UGLK1208 $614
No CM UGSL1200 $108
599 MZ/MT Series 1” 10-120
Yes TF UGSL1200 $108
656, 658 Series Yes 93 LF UGLK1350 $405
No LV UGVL Pg # 21-12
93
Yes LVK UGVL Pg # 21-13
658 Series
No SV UGVL Pg # 21-12
236
Yes SVK UGVL Pg # 21-13
SV UGVL Pg # 21-12
No
AM UGLK1200 $614
236
591 Series SVK UGVL Pg # 21-13
Yes
AF UGLK1200 $614
Yes 160 NF UGLK1200 $614
No AM UGLK1208 $614
221
Yes AF UGLK1208 $614
599 Flowrite 1¼” No SV UGVL Pg # 21-12
236
Yes SVK UGVL Pg # 21-13
Yes 110 NF UGLK1208 $614
No CM UGSL1200 $108
599 MZ/MT Series 10-120
Yes TF UGSL1200 $108
656, 658 Series Yes 65 LF UGLK1350 $405
No SV UGVL Pg # 21-12
658 Series 236
Yes SVK UGVL Pg # 21-13
No GM UGLK1200 $614
236
Yes GK UGLK1200 $614
SV UGVL Pg # 21-12
No
AM UGLK1200 $614
211
SVK UGVL Pg # 21-13
591 Series Yes
AF UGLK1200 $614

RETROFIT SOLUTIONS
No GM UGLK1202 $614
209
Yes GK UGLK1202 $614
No AM UGLK1202 $614
104
Yes AF UGLK1202 $614
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

1½”
Yes 77 NF UGLK1208 $614
SV UGVL Pg # 21-12
No
AM UGLK1208 $614
153
SVK UGVL Pg # 21-13
599 Flowrite Yes
AF UGLK1208 $614
All prices are in US Dollars (USD)

No GM UGLK1208 $614
236
Yes GK UGLK1208 $614
No 153 SV UGVL Pg # 21-12
No CM UGSL1200 $108
599 MZ/MT Series 10-120
Yes TF UGSL1200 $108
No GM UGLK1200 $614
236
Yes GK UGLK1200 $614
No AM UGLK1200 $614
120
Yes AF UGLK1200 $614
591 Series
No SV UGVL Pg # 21-12
85
Yes SVK UGVL Pg # 21-13
No SV UGVL Pg # 21-12
52
2” Yes SVK UGVL Pg # 21-13
No AM UGLK1208 $614
86
Yes AF UGLK1208 $614
No GM UGLK1208 $614
173
599 Flowrite Yes GK UGLK1208 $614
No SV UGVL Pg # 21-12
85
Yes SVK UGVL Pg # 21-13
Yes 40 NF UGLK1208 $614
No RV FGVL Pg # 21-12
591 Series 2½” 211
Yes 2*GK UGLK1270 $854

All close-off pressures listed are approximate and actual close-off pressures are based on valve condition and application.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

21-37
Siemens\Landis\Powers Warren Controls
591, 599 Series Valves 100, 1800, Type 20-22, Type 23, Type 30-32 Series Valves
Linkage/Actuator Selection Guide Linkage/Actuator Selection Guide

Belimo Belimo Linkage


Valve Body Model Size Fail-Safe Close-Off (psi)
Actuator Series Linkage List Price
No EV FGVL Pg # 21-12
591 Series 110 AVK FGVL Pg # 21-13
Yes
2½” 2*AF UGLK1270 $854
Yes 211 2*GK UGLK1272 $854
599 Flowrite
Yes 110 2*AF UGLK1272 $854
AVK FGVL Pg # 21-13
Yes 77
2*AF UGLK1270 $854
591 Series No RV FGVL Pg # 21-12
136
3” Yes 2*GK UGLK1270 $854
No 90 EV FGVL Pg # 21-12
Yes 77 2*AF UGLK1272 $854
599 Flowrite
Yes 136 2*GK UGLK1272 $854
GK UGLK1206 $614
Yes 22
2*AF UGLK1274 $854
No RV FGVL Pg # 21-12
591 Series 40
Yes 2*GK UGLK1274 $854
No 30 EV FGVL Pg # 21-12
4”
Yes 10 AF UGLK1206 $614
GK UGLK1212 $614
Yes 22
2*AF UGLK1276 $854
599 Flowrite
Yes 40 2*GK UGLK1276 $854
Yes 10 AF UGLK1212 $614
Yes 22 2*GK UGLK1274 $854
No 25 RV FGVL Pg # 21-12
591 Series No 20 EV FGVL Pg # 21-12
GK UGLK1206 $614
5” Yes 14
2*AF UGLK1274 $854
Yes 22 2*GK UGLK1276 $854
599 Flowrite GK UGLK1212 $614
Yes 14
2*AF UGLK1276 $854
No RV FGVL Pg # 21-12
22
591 Series 6” Yes 2*GK UGLK1274 $854
Yes 10 2*AF UGLK1274 $854
RETROFIT SOLUTIONS

WARREN CONTROLS
Yes 110 2*GK UGLK2272 $840
No RV WGVL Pg # 21-12
100 SGL SEAT 52
Yes AVK WGVL Pg # 21-13

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


No 26 EV WGVL Pg # 21-12
No 2*GM UGLK2272 $840
110
1800 3-Way Yes 2*GK UGLK2272 $840
No 52 EV WGVL Pg # 21-12
No 2*GM UGLK2272 $840
110

All prices are in US Dollars (USD)


1800 BAL Yes 2*GK UGLK2272 $840
2½”
No 52 EV WGVL Pg # 21-12
No 93 EV WGVL Pg # 21-12
Type 20-22 No 185 RV WGVL Pg # 21-12
Yes 71 AVK WGVL Pg # 21-13
No EV WGVL Pg # 21-12
Type 23 211
Yes AVK WGVL Pg # 21-13
No 93 EV WGVL Pg # 21-12
Type 30-32 No 185 RV WGVL Pg # 21-12
Yes 71 AVK WGVL Pg # 21-13
Yes 70 2*GK UGLK2272 $840
No 22 EV WGVL Pg # 21-12
100 SGL SEAT
No RV WGVL Pg # 21-12
40
Yes AVK WGVL Pg # 21-13
No 2*GM UGLK2272 $840
3” 70
1800 3-Way Yes 2*GK UGLK2272 $840
No 40 EV WGVL Pg # 21-12
No 2*GM UGLK2272 $840
70
1800 BAL Yes 2*GK UGLK2272 $840
No 40 EV WGVL Pg # 21-12

All close-off pressures listed are approximate and actual close-off pressures are based on valve condition and application.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

21-38
Warren Controls
Type 20-22, Type 23, Type 30-32, 100, 1800 Series Valves
Linkage/Actuator Selection Guide

Belimo Belimo Linkage


Valve Body Model Size Fail-Safe Close-Off (psi)
Actuator Series Linkage List Price
No 126 RV WGVL Pg # 21-12
Type 20-22 No 65 EV WGVL Pg # 21-12
Yes 40 AVK WGVL Pg # 21-13
No EV WGVL Pg # 21-12
Type 23 3” 160
Yes AVK WGVL Pg # 21-13
No 126 RV WGVL Pg # 21-12
Type 30-32 No 65 EV WGVL Pg # 21-12
Yes 40 AVK WGVL Pg # 21-13
No RV WGVL Pg # 21-12
22
Yes AVK WGVL Pg # 21-13
100 SGL SEAT Yes 40 2*GK UGLK2272 $840
No EV WGVL Pg # 21-12
10
Yes AF UGLK2202 $623
No 22 EV WGVL Pg # 21-12
1800 3-Way No 2*GM UGLK2272 $840
40
4” Yes 2*GK UGLK2272 $840
No 22 EV WGVL Pg # 21-12
1800 BAL No 2*GM UGLK2272 $840
40
Yes 2*GK UGLK2272 $840
Type 20-22 No 65 RV WGVL Pg # 21-12
No EV WGVL Pg # 21-12
Type 23 236
Yes AVK WGVL Pg # 21-13
Type 30-32 No 65 RV WGVL Pg # 21-12
Yes 22 2*GK UGLK2272 $840
No RV WGVL Pg # 21-12
100 SGL SEAT 14
Yes AVK WGVL Pg # 21-13
Yes 10 AF UGLK2202 $623
No 2*GM UGLK2272 $840
22
1800 3-Way Yes 2*GK UGLK2272 $840
No 14 EV WGVL Pg # 21-12
5” No 2*GM UGLK2272 $840
22
Yes 2*GK UGLK2272 $840
1800 BAL
No EV WGVL Pg # 21-12

RETROFIT SOLUTIONS
14
Yes AVK WGVL Pg # 21-13
Type 20-22 No 40 RV WGVL Pg # 21-12
No EV WGVL Pg # 21-12
Type 23 236
Yes AVK WGVL Pg # 21-13
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

Type 30-32 No 40 RV WGVL Pg # 21-12


Yes 22 2*GK UGLK2272 $840
No RV WGVL Pg # 21-12
100 SGL SEAT
10 AF UGLK2202 $623
Yes
AVK WGVL Pg # 21-13
All prices are in US Dollars (USD)

No 2*GM UGLK2272 $840


22
1800 3-Way Yes 2*GK UGLK2272 $840
No 10 EV WGVL Pg # 21-12
No 2*GM UGLK2272 $840
6” 22
1800 BAL Yes 2*GK UGLK2272 $840
No 10 EV WGVL Pg # 21-12
Yes 22 2*GK UGLK2272 $840
Type 20-22
Yes 10 2*AF UGLK2272 $840
Yes 22 2*GK UGLK2272 $840
Type 30
Yes 10 2*AF UGLK2272 $840
Yes 22 2*GK UGLK2272 $840
Type 32
Yes 10 2*AF UGLK2272 $840

All close-off pressures listed are approximate and actual close-off pressures are based on valve condition and application.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

21-39
Custom Globe Valve Solutions
UGSP Series Globe Valve Retrofit Solution

Globe valve retrofits that cannot be matched to one of the Belimo UGLK part numbers; please use part number UGSP0000 for valves
requiring single actuation and UGSP0002 for valves requiring dual actuation. These part numbers have no Bill of Materials (BOM)
associated with them, therefore cannot be produced and shipped. When these two part numbers are quoted, sold and orders processed,
the “Globe Valve Retrofit” form must be completed and accompany the order. Belimo’s engineering department will establish the correct
UGSP linkage number for production. UGSP0000 and UGSP0002 will NOT show up on final paperwork. The correct UGSP part number
will be stated.

UGSP0000 The single actuated globe retrofit linkage (shown left) depicts
dimensional data for use in determining the envelope space
B C D required to mount the linkage. These dimensions do NOT
include VALVE dimensions which will affect combined height
requirements.
Dims H1 & H2 are used only when override handles are utilized
H1
on the linkage system, and are not required for proper operation
of the linkage system.
A
Dim A 7.5” [190] to 14” [356] Dim H1 9.5” [242]
H2
Dim B 3” [76] Dim H2 9.5” [242]
Dim C 9” [229]
Dim D 5” [127]

List Price for UGSP0000 $824

UGSP0002 The dual actuated globe retrofit linkage (shown left) depicts
dimensional data for use in determining the envelope space
RETROFIT SOLUTIONS

B C D
required to mount the linkage. These dimensions do NOT
include VALVE dimensions which will affect combined height
requirements.

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


Dim A 9.5” [241] to 19” [483]
Dim B 3” [76]
Dim C 9” [229]
Dim D 5” [127]

All prices are in US Dollars (USD)


List Price for UGSP0002 $1,192

Custom kits are designed to your unique specifications and are not returnable.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

21-40
Custom Globe Valve Retrofit Solution Form
UGSP Series

Instructions for Completing this Form


Before completing this form, check with Belimo technical support if a UGVL will fit your valve.

Required tools needed a caliper, thread gauge, retrofit form, flashlight, and ladder (if applicable).

Dimensions A, B, & C relate to the existing valve stem. Dim A is the stem diameter where it is NOT threaded (Style A), or grooved (Style B). Dim
B refers to the length of the threaded region on the valve stem or top region of the grooved stem. Dim C is the actual thread specification for the
threaded style stem (1/4-28, 5/16-24, 3/8-24, 7/16-20 & 1/2-20 are typical). Dim C for the grooved style is the measurement of the stem groove
height. This information is used to design a stem adapter which will connect the valve stem to the new linkage drive rack. It is important to specify
the correct thread pattern, as incorrect data will prevent the stem adapter from attaching to your valve. If you cannot determine the correct thread
spec, you can send a nut from the valve stem and we will match the correct specification. In some cases where older valves are concerned, some
valve stems must be trimmed in the field to allow attachment of the linkage system. In these cases, a stem adapter is designed to “bite” into the
smooth surface of the valve stem itself.

Dimensions D1, D2 & D3 are used to determine the height of the linkage assembly required to clear the valves’ full stroke. A minimum of two
dimensions are required to manufacture the correct linkage system for your valve. These dimensions also provide the information necessary to
determine valve stroke. The maximum stroke from Belimo globe valve retrofit systems is 1.500”.

Dimension E refers to the valve bonnet diameter (regardless if threads are present or not). Over time, impurities will react to the bonnet threads and
corrode them to the point where they no longer meet the original thread specification. Because of this, we manufacture slip fit collars designed to
slide over the bonnet threads, and locking setscrews are provided which “bite” into the original threads. All retrofit systems are designed to work
with the raw valve body and do not account for previous actuation components which must be removed from the valve body before attaching the
new linkage system.

Dimension F refers to the thread specification on threaded bonnets, and refers to the minor diameter on slip on bonnets (Landis type). This
information helps us determine the length of the locking devices required to hold the collar onto the bonnet.

Dimensions G & H are used to determine working height of the bonnet region of your globe valve, while Dim I is used in calculating the minimum
ID of the collar that will fit over the packing nut. Additionally, information about the environment and process in which this linkage system will be
utilized should be provided.

RETROFIT SOLUTIONS
All the requested information contained on this form is required to guarantee the complete, perfect fit of your retrofit system. Keep in mind that
retrofit kits are designed with close-tolerance components which afford the most efficient linkage systems. Measurements rounded to the nearest
1/8 or 1/16 inch will not perform as well as a kit designed around careful measurements using proper equipment. Our designs are typically +.005”
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

tolerance.

DISCLAIMER:

We will do our best to provide a linkage system designed around your specifications and measurements. However, we cannot be held responsible
All prices are in US Dollars (USD)

for linkages which do not fit as a result of incorrect data given to Belimo. We will re-work components which do not fit properly for a nominal fee.
To reduce the possibility of incorrect linkage solutions, we respectfully request that you fill out the retrofit form completely and forward that
information with your order. This will serve as a double check between your valve and the actuator/linkage package designed for your application.
Actuation, weather shields and linkages cannot be pre-assembled at the Belimo factory prior to your receipt. The linkages are designed to be
attached onto the valve body first, then optional weather shields, and finally actuation products.
Close-off pressures are calculated using actuator torque, valve stroke, and valve area. Other factors may affect the rated close-off pressures,
including flow rates, system maintenance schedules, chemicals used in the shot feeder process, vicinity to pumps, condition of valve stem seals,
and assembly of linkage material in the field.
Valves that are being considered for retrofit of actuation should be analyzed for their life expectancy before the retrofit has taken place. Valves that leak
through stem seals or casings will continue to leak with the new linkage system in place, maybe even more so. Rebuilding the packing on these valves
may be more costly than replacing the valves themselves. In some instances, older valve stem heights will require field modifications to the valve in
order to utilize the retrofit kit. Belimo takes no responsibility for the operation of these valves after they have been modified.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

21-41
Custom Globe Valve Retrofit Solution Form
Custom Globe Valve Retrofit Form
UGSP Series ®

UGSP Series
VALVE STYLE 1 VALVE STYLE 2 VALVE STYLE 3
D2

D3 D1
E D2
D2
H F
G
E D3 D1 D3 D1
I
H G
G F E
F
(i.e. Barber Colman)
NOTE:
Internal Packing Nut
Nut "F" rotates on (i.e. Powers)
valve bonnet

VALVE STYLE 4 VALVE STYLE 5 VALVE STYLE DIMENSIONS

D2 D2 VALVE STYLE:
DIM D1*:
G Stem up, length to base mount surface
D3 D1 D3 D1
I E DIM D2: max.
E G F Stem stroke, stem up vs. stem down (D1-D3) 1.500”
F DIM D3:
E H
Stem down, length to base mount surface
External Packing Nut (i.e. Honeywell)
DIM E:
Bonnet major diameter
DIM F:
STEM STYLE A AØ STEM STYLE B AØ Thread spec or bonnet minor diameter
DIM G:
RETROFIT SOLUTIONS

Bonnet mount height


C B DIM H:
B C
Bonnet minor diameter height
DIM I:

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


External packaging nut, across points

*MAXIMUM LENGTH LINKAGE FRAME WILL


ACCOMODATE UP TO 6.500” D1 MEASUREMENT
VALVE STEMS LONGER THAN THIS NEED TO BE CUT.

All prices are in US Dollars (USD)


STEM STYLE STEM DIAMETER THREAD LENGTH TO STEM GROOVE THREADS PER INCH STEM GROOVE HEIGHT
A or B: DIM A: DIM B: DIM B: DIM C: DIM C:

ACTUATOR
EXISTING ACTUATOR MODEL: _______________________ CONTROL TYPE: ON/OFF FLOATING POINT VDC PWM
FAIL SAFE: YES NO Range:_____ Range:_____
FAIL POSITION: NO NC INDOOR OUTDOOR
VOLTAGE _____

COMPANY: VALVE MANUFACTURER: 2 WAY/3 WAY:


JOB NAME: VALVE SERIES: VALVE SIZE:
PO#: VALVE MODEL: MEDIA TEMP:
PHONE: VALVE TAG/LOCATION: MEDIA TYPE:
EMAIL: QUANTITY: SYSTEM PRESSURE:

NOTE: THIS INFORMATION WILL BE UTILIZED IN THE FABRICATION OF A CUSTOM LINKAGE SYSTEM FOR YOUR VALVE REQUIREMENT; THEREFORE, IT IS ESSENTIAL THAT THE
ABOVE DIMENSIONS BE FURNISHED WITH READINGS TAKEN TO THE NEAREST .001". ANY ERRONEOUS DIMENSIONS FURNISHED WHICH RESULT IN IMPROPER FIT OF THIS LINKAGE
SYSTEM ARE NOT THE RESPONSIBILITY OF BELIMO AIRCONTROLS. ANY REWORK REQUIRED WILL RESULT IN AN EXTRA CHARGE.

CUSTOM KITS ARE DESIGNED TO YOUR UNIQUE SPECIFICATIONS AND ARE NOT RETURNABLE.
COMPANY CONTACT/DIMENSIONS PROVIDED BY: ____________________________________________________________________ DATE: ___________________

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

21-42
Butterfly Valve Retrofit Solution

How to Select a Butterfly Valve Retrofit Solution


Follow the four steps listed below when ordering a butterfly valve retrofit kit.
Example: Centerline C200 Series, 2½” valve, using a Non Fail-Safe Belimo actuator.

1 Identify the Valve Manufacturer, Valve Series and Valve Size.

2 Determine the type of actuator you require: Belimo non fail-safe, spring return, or electronic fail-safe. Belimo non fail-safe and
fail-safe actuators are typically only available on smaller sizes.
Look at the solution using the Non Fail-Safe Belimo Actuator. Looking at the UFLK3500, the GM Series actuator will provide a
200 psi close-off for the 2½” valve with Non Fail-Safe actuation.

3 Use the actuator listings to make your final actuator selection. Decide between GMB24-3-X1 and GMB24-MFT-X1.
ACTUATOR NOT INCLUDED IN THE LIST PRICE OF THE LINKAGE.

4 HOW TO ORDER: Item 1 1pc UFLK3500


Item 2 1pc GMB24-MFT-X1

Select linkage solution


based on the Valve
Number, Configuration, Centerline
1 and Size; select the C200 Round Top Series Butterfly Valves
Linkage/Actuator Selection Guide
proper Linkage Solution
for your valve. Belimo
Valve Close-Off Belimo
Valve Body Model Size Fail-Safe Actuator Series
Configuration psi Linkage

C200 Round Top Series Butterfly 2-way 2” No 200 AM UFLK3500


Valves
SY1 UFLK3538
UFLK3500

RETROFIT SOLUTIONS
Yes 200 AF UFLK3500
Example: Centerline C200 Series, 2½” No 200 GM UFLK3500
2½” valve using a non fail-safe Belimo SY1 UFLK3538
actuation. Yes 200 2*AF UFLK3502
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

GK
Choose correct linkage UFLK3500. UFLK3500
3” No 200 GM UFLK3500
SY1 UFLK3538
Yes 200 2*AF UFLK3502
GK UFLK3500
Verify close-off is suitable
All prices are in US Dollars (USD)

for application. BASIC PRODUCTS


Looking at the UFLK3500,
2 the GM Series actuator will Model Control Input Feedback
Power
Running
Time(s) VA Rating
Auxiliary
Cable Length
Supply Switch
[Default]
provide 200 psi close-off for
GMB24-3-X1 On/Off, Floating Point Add-on 24 VAC/DC 150 seconds 6 Add-on 3 ft.
the 2½” valve. GMB24-SR 2-10 VDC (4-20 mA*) 2-10 VDC 24 VAC/DC 150 seconds 6.5 Add-on 3 ft.
GMB24-MFT-X1 2-10 VDC 2-10 VDC 24 VAC/DC 150 seconds 7 Add-on 3 ft.
 Variable with MFT
‡ Prices do not reflect additional programming code surcharge.
NOTE: 10’ and 16’ cables are available with a $28.00 and $48.00 adder except for the PC and MFT95 version, which are only available with a 3’ cable.

Select actuator based on


needed control type.
Decide between GMB24-3-X1
3 and GMB24-MFT-X1.
Consult actuator overview
section for full details.

Complete Ordering Example:


4 Item 1: UFLK3500
Item 2: GMB24-MFT-X1

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

21-43
Butterfly Valve Retrofit Actuators
Actuator Selection Guide

SY ACTUATORS
CONTROL TYPE
Run Time(s) Duty Floating
SERIES MODEL Torque Power Supply Modulating On/Off Feedback List Price
90°@60Hz Cycle Point
SY4-110 19 seconds 120 VAC ±10%, 50/60 Hz 30% • • none, opt 1k $3,306
SY4-24 20 seconds 24 VAC/DC ±10%, 50/60 Hz 30% • • none, opt 1k $3,306
SY4-220 20 seconds 3540 in-lbs 230 VAC ±10%, 50/60 Hz 30% • • none, opt 1k $3,306
SY4
SY4-24MFT 20 seconds [400 Nm] 24 VAC/DC ±10%, 50/60 Hz 75% • 2-10 VDC/4-20 mA $6,073
SY4-120MFT 24 seconds 120 VAC ±10%, 50/60 Hz 75% • 2-10 VDC/4-20 mA $6,073
SY4-230MFT 22 seconds 230 VAC ±10%, 50/60 Hz 75% • 2-10 VDC/4-20 mA $6,073
SY5-110 26 seconds 120 VAC ±10%, 50/60 Hz 30% • • none, opt 1k $3,823
SY5-24 26 seconds 24 VAC/DC ±10%, 50/60 Hz 30% • • none, opt 1k $3,823
SY5-220 26 seconds 4450 in-lbs 230 VAC ±10%, 50/60 Hz 30% • • none, opt 1k $3,823
SY5
SY5-24MFT 26 seconds [500 Nm] 24 VAC/DC ±10%, 50/60 Hz 75% • 2-10 VDC/4-20 mA $6,612
SY5-120MFT 28 seconds 120 VAC ±10%, 50/60 Hz 75% • 2-10 VDC/4-20 mA $6,612
SY5-230MFT 28 seconds 230 VAC ±10%, 50/60 Hz 75% • 2-10 VDC/4-20 mA $6,612
SY6-110 34 seconds 120 VAC ±10%, 50/60 Hz 30% • • none, opt 1k $4,633
SY6-220 34 seconds 5785 in-lbs 230 VAC ±10%, 50/60 Hz 30% • • none, opt 1k $4,633
SY6
SY6-120MFT 38 seconds [650 Nm] 120 VAC ±10%, 50/60 Hz 75% • 2-10 VDC/4-20 mA $7,467
SY6-230MFT 35 seconds 230 VAC ±10%, 50/60 Hz 75% • 2-10 VDC/4-20 mA $7,467
SY7-110 50 seconds 120 VAC ±10%, 50/60 Hz 30% • • none, opt 1k $5,562
8900 in-lbs
SY7 SY7-120MFT 59 seconds 120 VAC ±10%, 50/60 Hz 75% • 2-10 VDC/4-20 mA $8,331
[1000 Nm]
SY7-230MFT 59 seconds 230 VAC ±10%, 50/60 Hz 75% • 2-10 VDC/4-20 mA $8,331
SY8-110 51 seconds 120 VAC ±10%, 50/60 Hz 30% • • none, opt 1k $7,698
13350 in-lbs
SY8 SY8-120MFT 79 seconds 120 VAC ±10%, 50/60 Hz 75% • 2-10 VDC/4-20 mA $10,528
[1500 Nm]
SY8-230MFT 79 seconds 230 VAC ±10%, 50/60 Hz 75% • 2-10 VDC/4-20 mA $10,528
SY9-110 62 seconds 120 VAC ±10%, 50/60 Hz 30% • • none, opt 1k $9,527
17800 in-lbs
SY9 SY9-120MFT 65 seconds 120 VAC ±10%, 50/60 Hz 50% • 2-10 VDC/4-20 mA $12,380
[2000 Nm]
SY9-230MFT 72 seconds 230 VAC ±10%, 50/60 Hz 50% • 2-10 VDC/4-20 mA $12,380
SY10-110 62 seconds 120 VAC ±10%, 50/60 Hz 30% • • none, opt 1k $9,999
22250 in-lbs
SY10 SY10-120MFT 76 seconds 120 VAC ±10%, 50/60 Hz 50% • 2-10 VDC/4-20 mA $12,856
[2500 Nm]
SY10-230MFT 85 seconds 230 VAC ±10%, 50/60 Hz 50% • 2-10 VDC/4-20 mA $12,856
SY11-110 62 seconds 120 VAC ±10%, 50/60 Hz 30% • • none, opt 1k $13,308
26700 in-lbs
SY11 SY11-120MFT 71 seconds 120 VAC ±10%, 50/60 Hz 50% • 2-10 VDC/4-20 mA $16,180
[3000 Nm]
SY11-230MFT 61 seconds 230 VAC ±10%, 50/60 Hz 50% • 2-10 VDC/4-20 mA $16,180
SY12-110 62 seconds 120 VAC ±10%, 50/60 Hz 30% • • none, opt 1k $14,245
RETROFIT SOLUTIONS

31150 in-lbs
SY12 SY12-120MFT 76 seconds 120 VAC ±10%, 50/60 Hz 50% • 2-10 VDC/4-20 mA $16,931
[3500 Nm]
SY12-230MFT 65 seconds 230 VAC ±10%, 50/60 Hz 50% • 2-10 VDC/4-20 mA $16,931
Modulating actuators will accept 0-10 VDC, 2-10 VDC, or 4-20 mA control signals as standard.
All SY-MFT actuators are 0.5VDC start. Below this will be considered a loss of signal.

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


All SY actuators are non fail-safe, but can be used with NSV-SY back up systems for spring return applications.
These products carry a two year warranty when sold as part of an assembly or with a UFLK retrofit kit.

All prices are in US Dollars (USD)

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

21-44
Butterfly Valve Retrofit Actuators
Actuator Selection Guide

ROTARY ACTUATORS
Tandem
Spring Electronic Feedback Power
SERIES TORQUE MODEL Mounting Control Input List Price
Return Fail-Safe Position Supply
Available
AFBUP-X1 • • On/Off - 24-240 VAC $635
180 in-lbs
AF Series* Variable with MFT variable
[20 Nm] AFX24-MFT-X1 • • 24 VAC/DC $778
(VDC, PWM, Floating Point, On/Off) VDC
AMB24-3-X1 Floating Point, On/Off - 24 VAC/DC $421
180 in-lbs
AM Series* Variable with MFT variable
[20 Nm] AMX24-MFT-X1 24 VAC/DC $650
(VDC, PWM, Floating Point, On/Off) VDC
GMB24-3-X1 Floating Point, On/Off - 24 VAC/DC $573
360 in-lbs
GM Series* Variable with MFT variable
[40 Nm] GMX24-MFT-X1 • 24 VAC/DC $839
(VDC, PWM, Floating Point, On/Off) VDC
GKB24-3-X1 • Floating Point, On/Off - 24 VAC $1,270
360 in-lbs
GK Series* Variable with MFT variable
[40 Nm] GKX24-MFT-X1 • • 24 VAC/DC $1,747
(VDC, PWM, Floating Point, On/Off) VDC

PRBUP-3-T Floating Point, On/Off - 24-240 VAC/ $2,503


PR Series 24-125 VDC,
1400 in-lbs PRBUP-MFT-T Variable with MFT variable 50/60 Hz $4,797
[160 Nm] (VDC, PWM, Floating Point, On/Off) VDC
24-240 VAC/
Variable with MFT variable
PKR Series PKRBUP-MFT-T • 24-125 VDC, $5,831
(VDC, PWM, Floating Point, On/Off) VDC
50/60 Hz
*Please consult the Damper sections for a full list of product offerings. Standard run times should be considered in the selection. All air side products are applicable for retrofit kits.
Select “X1” actuators come with a handle.

MULTI-FUNCTION TECHNOLOGY
P-CODE Control Input Running Time Built-in Feedback List Price
P-10001 A01 2-10 VDC 150 seconds 2-10 VDC No Charge
ROTARY ACTUATOR CODES

P-10002 A02 0-10 VDC 150 seconds 0-10 VDC No Charge


P-10028 A28 0-10 VDC 150 seconds 0-10 VDC No Charge
P-10063 A63 0.5-4.5 VDC 150 seconds 0.5-4.5 VDC No Charge

RETROFIT SOLUTIONS
P-10064 A64 5.5-10 VDC 150 seconds 5.5-10 VDC No Charge
P-20002 W02 0.02-5.00 seconds PWM 150 seconds 2-10 VDC No Charge
P-20003 W03 0.10-25.5 seconds PWM 150 seconds 2-10 VDC No Charge
P-30001 F01 Floating Point 150 seconds 2-10 VDC No Charge
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

P-40002 J02 On/Off 150 seconds 2-10 VDC No Charge


Consult Belimo for programming code, if not shown on chart.

SY MULTI-FUNCTION TECHNOLOGY
All prices are in US Dollars (USD)

Description MFT-CODE Control Input Built-in Feedback Loss of Signal Running Time List Price
MFT ACE 2-10 VDC 2-10 VDC stop actuator(s) constant No Charge
MFT ACF 0.5-10 VDC 0.5-10 VDC stop actuator(s) constant No Charge
MFT ACG 4-20 mA 4-20 mA stop actuator(s) constant No Charge
MFT ACH 4-20 mA 2-10 VDC stop actuator(s) constant No Charge
MFT ACJ 2-10 VDC 2-10 VDC open actuator(s) constant No Charge
MFT ACK 0.5-10 VDC 0.5-10 VDC open actuator(s) constant No Charge
MFT ACL 4-20 mA 4-20 mA open actuator(s) constant No Charge
MFT ACM 4-20 mA 2-10 VDC open actuator(s) constant No Charge
MFT ACN 2-10 VDC 2-10 VDC close actuator(s) constant No Charge
MFT ACP 0.5-10 VDC 0.5-10 VDC close actuator(s) constant No Charge
MFT ACR 4-20 mA 4-20 mA close actuator(s) constant No Charge
MFT ACS 4-20 mA 2-10 VDC close actuator(s) constant No Charge
All other configurations carry a $37.00 list price.
Standard delivery may vary, please consult your customer service representative for the latest lead time(s).

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

21-45
Bray
30/31, 40/41 Series Butterfly Valves
Linkage/Actuator Selection Guide

Valve Belimo Belimo Linkage


Valve Body Model Fail-Safe Size
Configuration Linkage Actuator Series List Price
UFLK1100 AM $426
2”
UFLKP004 PR $778
UFLK1100 GM $426
2½”
UFLKP004 PR $778
UFLK1102 2*GM $542
3”
UFLKP004 PR $778
UFLK1108 2*GM $550
4”
UFLKP008 PR $778
No 5” UFLKP014 PR $778
6” UFLKP014 PR $778
8” UFLK1138 SY4 $778
10” UFLK1140 SY4 $778
2-way
12” UFLK1142 SY6 $778
14” UFLK1144 SY7 $898
16” UFLK1144 SY8 $898
18” UFLK1146 SY9 $978
20” UFLK1146 SY10 $978
2” UFLK1102 2*AF $542
UFLK1102 2*AF $542
2½”
UFLK1100 GK $426
Yes 3” UFLK1102 2*GK $542
30/31 Series Butterfly Valves
4” UFLK1108 2*GK $550
5” UFLKP014 PKR $778
6” UFLKP014 PKR $778
2” UFLKP104 PR $1,420
UFLK4102 2*GM $898
2½”
UFLKP104 PR $1,420
UFLK4102 2*GM $898
3”
UFLKP104 PR $1,420
4” UFLKP108 PR $1,131
5” UFLK4136 SY4 $1,131
No 6” UFLK4136 SY4 $1,131
8” UFLK4138 SY5 $1,131
RETROFIT SOLUTIONS

3-way
10” UFLK4140 SY6 $1,420
12” UFLK4142 SY7 $1,420
14” UFLK4144 SY8 $1,529
16” UFLK4146 SY9 $2,304

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


18” UFLK4148 SY11 $2,304
20” UFLK4148 SY12 $2,304
2” UFLK4102 2*AF $898
Yes 2½” UFLK4102 2*GK $898
3” UFLK4102 2*GK $898

All prices are in US Dollars (USD)


UFLK1200 2*GM $538
2½”
UFLKP008 PR $778
UFLK1200 2*GM $538
3”
UFLKP008 PR $778
UFLK1200 2*GM $538
4”
UFLKP008 PR $778
5” UFLKP014 PR $778
No 6” UFLK1228 SY4 $772
8” UFLK1230 SY4 $772
2-way
10” UFLK1232 SY6 $772
12” UFLK1234 SY7 $772
40/41 Series Butterfly Valves
14” UFLK1236 SY8 $977
16” UFLK1238 SY9 $1,097
18” UFLK1240 SY11 $1,097
20” UFLK1242 SY12 $1,097
2½” UFLK1200 2*GK $538
Yes 3” UFLK1200 2*GK $538
4” UFLK1200 2*GK $538
UFLK4200 2*GM $898
2½”
UFLKP108 PR $1,131
3-way No
UFLK4200 2*GM $898
3”
UFLKP108 PR $1,131

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

21-46
Bray Centerline
40/41 Series Butterfly Valves C200 Round Top Series Butterfly Valves
Linkage/Actuator Selection Guide Linkage/Actuator Selection Guide

Valve Belimo Belimo Linkage


Valve Body Model Fail-Safe Size
Configuration Linkage Actuator Series List Price
4” UFLKP108 PR $1,131
5” UFLK4224 SY4 $1,131
6” UFLK4224 SY4 $1,131
8” UFLK4226 SY5 $1,131
No
10” UFLK4228 SY7 $1,420
40/41 Series Butterfly Valves 3-way
12” UFLK4230 SY8 $1,420
14” UFLK4232 SY10 $2,909
16” UFLK4234 SY12 $2,909
2½” UFLK4200 2*GK $898
Yes
3” UFLK4200 2*GK $898
CENTERLINE
UFLK3500 AM $431
2”
UFLKP030 PR $758
UFLK3500 GM $431
2½”
UFLKP030 PR $758
UFLK3500 GM $431
3”
UFLKP030 PR $758
UFLK3508 2*GM $542
4”
UFLKP031 PR $758
5” UFLKP032 PR $758
No
6” UFLKP032 PR $758
8” UFLK3546 SY4 $834
10” UFLK3548 SY4 $901
12” UFLK3550 SY5 $824
2-way
14” UFLK3550 SY5 $824
16” UFLK3552 SY7 $942
18” UFLK3554 SY8 $942
20” UFLK3556 SY8 $942
24” UFLK3558 SY10 $1,446
2” UFLK3500 AF $431
UFLK3502 2*AF $667
2½”
UFLK3500 GK $431
UFLK3502 2*AF $667

RETROFIT SOLUTIONS
Yes 3”
UFLK3500 GK $431
4” UFLK3508 2*GK $542
C200 Round Top Series Butterfly Valves
5” UFLKP032 PKR $758
6” UFLKP032 PKR $758
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

UFLK6500 AM $778
2”
UFLKP130 PR $1,383
UFLK6500 GM $778
2½”
UFLKP130 PR $1,383
UFLK6502 2*GM $845
3”
All prices are in US Dollars (USD)

UFLKP130 PR $1,383
UFLK6508 2*GM $845
4”
UFLKP131 PR $1,383
No 5” UFLKP132 PR $1,383
6” UFLK6544 SY4 $1,420
8” UFLK6546 SY4 $1,420
3-way
10” UFLK6548 SY5 $1,420
12” UFLK6550 SY7 $1,507
14” UFLK6550 SY7 $1,507
16” UFLK6552 SY8 $2,199
18” UFLK6554 SY9 $2,909
20” UFLK6556 SY10 $2,909
2” UFLK6502 2*AF $845
UFLK6502 2*AF $845
2½”
Yes UFLK6500 GK $778
3” UFLK6502 2*GK $845
4” UFLK6508 2*GK $845

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

21-47
Centerline
C200 Square Top, C225 Square Top Series Butterfly Valves
Linkage/Actuator Selection Guide

Valve Belimo Belimo Linkage


Valve Body Model Fail-Safe Size
Configuration Linkage Actuator Series List Price
UFLK1300 AM $431
2”
UFLKP004 PR $778
UFLK1300 GM $431
2½”
UFLKP004 PR $778
UFLK1300 GM $431
3”
UFLKP004 PR $778
UFLK1308 2*GM $542
4”
UFLKP011 PR $778
5” UFLKP016 PR $778
No
6” UFLKP016 PR $778
8” UFLK1346 SY4 $778
10” UFLK1348 SY4 $778
12” UFLK1350 SY5 $778
2-way
14” UFLK1350 SY5 $778
16” UFLK1352 SY7 $778
18” UFLK1354 SY8 $778
20” UFLK1356 SY8 $778
24” UFLK1358 SY10 $834
2” UFLK1300 AF $431
UFLK1302 2*AF $542
2½”
UFLK1300 GK $431
UFLK1302 2*AF $542
Yes 3”
UFLK1300 GK $431
4” UFLK1308 2*GK $542
C200 Square Top Series Butterfly Valves
5” UFLKP016 PKR $778
6” UFLKP016 PKR $778
UFLK4300 AM $778
2”
UFLKP104 PR $1,420
UFLK4300 GM $778
2½”
UFLKP104 PR $1,420
UFLK4302 2*GM $834
3”
UFLKP104 PR $1,420
UFLK4308 2*GM $834
RETROFIT SOLUTIONS

4”
UFLKP111 PR $1,420
No 5” UFLKP116 PR $1,131
6” UFLK4346 SY4 $1,154
8” UFLK4348 SY4 $1,131

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


3-way
10” UFLK4350 SY5 $1,185
12” UFLK4352 SY7 $1,459
14” UFLK4352 SY7 $1,459
16” UFLK4354 SY8 $2,261
18” UFLK4356 SY9 $2,909

All prices are in US Dollars (USD)


20” UFLK4358 SY10 $2,909
2” UFLK4302 2*AF $834
UFLK4302 2*AF $834
2½”
Yes UFLK4300 GK $778
3” UFLK4302 2*GK $834
4” UFLK4308 2*GK $834
UFLK1400 GM $487
2”
UFLKP004 PR $778
UFLK1400 GM $487
2½”
UFLKP004 PR $778
UFLK1400 GM $487
3”
C225 Square Top Series Butterfly Valves 2-way No UFLKP004 PR $778
UFLK1408 2*GM $542
4”
UFLKP011 PR $778
5” UFLKP016 PR $778
6” UFLK1444 SY4 $834
8” UFLK1446 SY4 $778

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

21-48
Centerline Johnson Controls
C225 Square Top Series Butterfly Valves VF...(H) Series Butterfly Valves
Linkage/Actuator Selection Guide Linkage/Actuator Selection Guide

Valve Belimo Belimo Linkage


Valve Body Model Fail-Safe Size
Configuration Linkage Actuator Series List Price
10” UFLK1448 SY5 $778
12” UFLK1450 SY6 $778
14” UFLK1452 SY7 $778
No
16” UFLK1454 SY9 $1,071
18” UFLK1456 SY10 $1,071
20” UFLK1458 SY10 $834
UFLK1402 2*AF $655
2”
2-way UFLK1400 GK $487
UFLK1402 2*AF $655
2½”
UFLK1400 GK $487
Yes UFLK1402 2*AF $655
3”
UFLK1400 GK $487
UFLK1408 2*GK $542
4”
UFLKP011 PKR $778
5” UFLKP016 PKR $778
UFLK4400 GM $778
2”
UFLKP104 PR $1,420
C225 Square Top Series Butterfly Valves UFLK4400 GM $778
2½”
UFLKP104 PR $1,420
UFLK4402 2*GM $834
3”
UFLKP104 PR $1,420
4” UFLKP111 PR $1,420
No
5” UFLKP116 PR $1,131
6” UFLK4444 SY4 $1,131
8” UFLK4446 SY5 $1,420
3-way
10” UFLK4448 SY7 $1,420
12” UFLK4450 SY8 $1,420
14” UFLK4452 SY8 $1,420
16” UFLK4454 SY12 $2,909
2” UFLK4400 GK $778
2½” UFLK4400 GK $778
UFLK4402 2*GK $834
Yes 3”
UFLKP104 PKR $1,420

RETROFIT SOLUTIONS
4” UFLKP111 PKR $1,420
5” UFLKP116 PKR $1,131
JOHNSON CONTROLS
2” UFLK2100 GM $425
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

UFLK2100 GM $425
2½”
UFLKP007 PR $834
UFLK2100 GM $425
3”
UFLKP007 PR $834
UFLK2108 2*GM $542
4”
All prices are in US Dollars (USD)

UFLKP009 PR $834
No
5” UFLKP015 PR $834
6” UFLK2144 SY4 $834
8” UFLK2158 SY4 $834
2-way 12” UFLK2148 SY7 $834
14” UFLK2156 SY7 $834
VF.. (H) Series Butterfly Valves
18” UFLK2152 SY10 $998
20” UFLK2154 SY10 $998
UFLK2102 2*AF $542
2”
UFLK2100 GK $425
UFLK2102 2*AF $542
2½”
Yes UFLK2100 GK $425
UFLK2102 2*AF $542
3”
UFLK2100 GK $425
4” UFLK2108 2*GK $542
2” UFLK5100 GM $834
3-way No 2½” UFLK5102 2*GM $898
3” UFLK5102 2*GM $898

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

21-49
Johnson Controls Keystone
VF...(H) Series Butterfly Valves 360/362, 370/372, AR1/AR2 Series Butterfly Valves
Linkage/Actuator Selection Guide Linkage/Actuator Selection Guide

Valve Belimo Belimo Linkage


Valve Body Model Fail-Safe Size
Configuration Linkage Actuator Series List Price
4” UFLKP109 PR $1,131
5” UFLK5136 SY4 $1,420
6” UFLK5136 SY4 $1,420
8” UFLK5138 SY5 $1,420
No 12” UFLK5142 SY7 $1,420
14” UFLK5144 SY8 $1,420
VF.. (H) Series Butterfly Valves 3-way 16” UFLK5146 SY9 $2,909
18” UFLK5148 SY11 $2,909
20” UFLK5150 SY12 $2,909
UFLK5102 2*AF $898
2”
UFLK5100 GK $834
Yes
2½” UFLK5102 2*GK $898
3” UFLK5102 2*GK $898
KEYSTONE
3” UFLK2408 2*GM $542
UFLK2414 2*GM $542
4”
UFLKP013 PR $834
5” UFLKP013 PR $834
10” UFLK2452 SY4 $834
No
14” UFLK2456 SY6 $778
16” UFLK2458 SY6 $834
2-way
18” UFLK2460 SY7 $984
20” UFLK2462 SY9 $1,107
24” UFLK2464 SY9 $1,107
UFLK2402 2*AF $497
2½”
UFLK2400 GK $497
Yes
3” UFLK2408 2*GK $542
360/362 Series Butterfly Valves, K-LOK
4” UFLK2414 2*GK $542
2½” UFLK5400 GM $778
4” UFLK5414 2*GM $898
10” UFLK5450 SY4 $1,420
14” UFLK5454 SY7 $2,261
No
16” UFLK5456 SY8 $2,261
RETROFIT SOLUTIONS

18” UFLK5458 SY9 $2,909


3-way
20” UFLK5460 SY11 $2,909
24” UFLK5462 SY12 $2,909
UFLK5402 2*AF $898
2½”

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


UFLK5400 GK $778
Yes
3” UFLK5408 2*GK $898
4” UFLK5414 2*GK $898
4” UFLK2530 SY4 $834
5” UFLK2530 SY4 $834
2-way No

All prices are in US Dollars (USD)


12” UFLK2538 SY9 $1,493
14” UFLK2540 SY9 $1,071
370/372 Series Butterfly Valves, K-LOK
4” UFLK5530 SY4 $1,420
5” UFLK5530 SY4 $1,420
3-way No
8” UFLK5534 SY8 $1,420
14” UFLK5540 SY12 $2,909
2” UFLK2300 GM $496
2½” UFLK2300 GM $496
3” UFLK2300 GM $496
UFLK2308 2*GM $540
4”
UFLKP009 PR $834
5” UFLKP013 PR $834
AR1/AR2 Series Butterfly Valves 2-way No
6” UFLK2356 SY4 $772
8” UFLK2342 SY4 $778
10” UFLK2344 SY5 $822
12” UFLK2346 SY7 $1,003
20” UFLK2352 SY11 $1,090
24” UFLK2354 SY12 $1,090

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

21-50
Keystone
AR1/AR2, Figure 222/221 Series Butterfly Valves
Linkage/Actuator Selection Guide

Valve Belimo Belimo Linkage


Valve Body Model Fail-Safe Size
Configuration Linkage Actuator Series List Price
2” UFLK2300 GK $496
UFLK2302 2*AF $540
2½”
UFLK2300 GK $496
2-way Yes
UFLK2302 2*AF $540
3”
UFLK2300 GK $496
4” UFLK2308 2*GK $540
2” UFLK5300 GM $778
2½” UFLK5300 GM $778
4” UFLKP109 PR $1,131
5” UFLK5338 SY4 $1,420
AR1/AR2 Series Butterfly Valves
No 6” UFLK5338 SY4 $1,420
8” UFLK5340 SY5 $1,420
12” UFLK5344 SY8 $1,529
3-way
16” UFLK5348 SY10 $2,909
18” UFLK5350 SY12 $2,909
UFLK5302 2*AF $898
2”
UFLK5300 GK $778
Yes UFLK5302 2*AF $898
2½”
UFLK5300 GK $778
3” UFLK5302 2*GK $898
UFLK2200 GM $426
2”
UFLKP003 PR $834
UFLK2200 GM $426
2½”
UFLKP003 PR $834
UFLK2200 GM $426
3”
UFLKP003 PR $834
No UFLK2208 2*GM $542
4”
UFLKP009 PR $834
5” UFLKP013 PR $834
6” UFLK2232 SY4 $778
2-way
8” UFLK2234 SY4 $778
10” UFLK2236 SY5 $778
12” UFLK2238 SY7 $1,011

RETROFIT SOLUTIONS
UFLK2202 2*AF $542
2”
UFLK2200 GK $426
UFLK2202 2*AF $542
2½”
Yes UFLK2200 GK $426
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

UFLK2202 2*AF $542


3”
Figure 222/221 Series Butterfly Valves UFLK2200 GK $426
4” UFLK2208 2*GK $542
UFLK5200 GM $679
2”
UFLKP103 PR $1,420
All prices are in US Dollars (USD)

UFLK5200 GM $679
2½”
UFLKP103 PR $1,420
UFLK5202 2*GM $898
3”
UFLKP103 PR $1,420
No
4” UFLKP109 PR $1,131
5” UFLK5228 SY4 $1,420
3-way 6” UFLK5228 SY4 $1,420
8” UFLK5230 SY5 $1,420
10” UFLK5232 SY7 $1,529
12” UFLK5234 SY8 $1,529
UFLK5202 2*AF $898
2”
UFLK5200 GK $679
Yes UFLK5202 2*AF $898
2½”
UFLK5200 GK $679
3” UFLK5202 2*GK $898

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

21-51
Milwaukee
CL, ML Series Butterfly Valves
Linkage/Actuator Selection Guide

Valve Belimo Belimo Linkage


Valve Body Model Fail-Safe Size
Configuration Linkage Actuator Series List Price
2” UFLK2600 AM $542
2½” UFLK2600 AM $542
3” UFLK2600 GM $542
UFLK2608 2*GM $667
4”
UFLKP005 PR $834
No UFLK2608 2*GM $667
5”
UFLKP005 PR $834
6” UFLKP010 PR $778
2-way
8” UFLK2634 SY4 $778
10” UFLK2636 SY4 $778
12” UFLK2636 SY5 $778
2” UFLK2600 AF $542
2½” UFLK2600 AF $542
CL Series Butterfly Valves Yes 3” UFLK2600 GK $542
4” UFLK2608 2*GK $667
5” UFLK2608 2*GK $667
2” UFLK5600 AM $891
2½” UFLK5600 GM $891
3” UFLK5600 GM $891
No 4” UFLK5608 2*GM $891
6” UFLK5628 SY4 $1,420
3-way 8” UFLK5630 SY4 $1,420
10” UFLK5632 SY6 $1,420
UFLK5602 2*AF $891
2½”
UFLK5600 GK $891
Yes
UFLK5602 2*AF $891
3”
UFLK5600 GK $891
2” UFLK2700 AM $425
2½” UFLK2700 AM $425
3” UFLK2700 GM $425
UFLK2708 2*GM $530
4”
UFLKP005 PR $834
UFLK2708 2*GM $530
RETROFIT SOLUTIONS

5”
UFLKP005 PR $834
No 6” UFLKP010 PR $778
8” UFLK2740 SY4 $834
10” UFLK2742 SY4 $834

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


2-way
12” UFLK2742 SY5 $834
14” UFLK2744 SY7 $834
16” UFLK2744 SY7 $834
18” UFLK2746 SY8 $834
24” UFLK2750 SY10 $994

All prices are in US Dollars (USD)


2” UFLK2700 AF $425
2½” UFLK2700 AF $425
ML Series Butterfly Valves
Yes 3” UFLK2700 GK $425
4” UFLK2708 2*GK $530
5” UFLK2708 2*GK $530
2” UFLK5700 AM $679
3” UFLK5700 GM $679
4” UFLK5708 2*GM $891
8” UFLK5740 SY4 $1,420
3-way No 10” UFLK5742 SY6 $1,420
12” UFLK5744 SY7 $1,420
14” UFLK5746 SY8 $1,420
16” UFLK5748 SY9 $2,909
20” UFLK5750 SY11 $2,909
2” UFLK5702 2*AF $891
2½” UFLK5702 2*AF $891
2-way Yes UFLK5702 2*AF $891
3”
UFLK5700 GK $679
4” UFLK5708 2*GK $891

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

21-52
Nibco PDC
LD1/WD1, LD2/WD2, LD3 Series Butterfly Valves 27 Series Butterfly Valves
Linkage/Actuator Selection Guide Linkage/Actuator Selection Guide

Valve Belimo Belimo Linkage


Valve Body Model Fail-Safe Size
Configuration Linkage Actuator Series List Price
14” UFLK2960 SY7 $1,003
16” UFLK2968 SY8 $1,003
2-way No 18” UFLK2962 SY8 $910
20” UFLK2964 SY9 $834
LD1/WD1 Series Butterfly Valves 24” UFLK2966 SY11 $834
14” UFLK5956 SY8 $2,261
16” UFLK5958 SY9 $2,261
3-way No
18” UFLK5960 SY10 $2,261
20” UFLK5962 SY12 $2,261
2” UFLK2900 GM $466
UFLK2908 GM $426
2½”
UFLKP002 PR $834
UFLK2910 2*GM $609
3”
UFLKP002 PR $834
UFLK2916 2*GM $609
No 4”
UFLKP006 PR $834
5” UFLKP012 PR $729
6” UFLKP012 PR $729
8” UFLK2954 SY4 $778
2-way
10” UFLK2956 SY4 $783
12” UFLK2958 SY6 $910
UFLK2902 2*AF $542
2”
UFLK2900 GK $466
UFLK2910 2*AF $609
2½”
UFLK2908 GK $426
LD2/WD2, LD3 Series Butterfly Valves Yes
3” UFLK2910 2*GK $609
4” UFLK2916 2*GK $609
5” UFLKP012 PKR $729
6” UFLKP012 PKR $729
2” UFLK5900 GM $724
2½” UFLK5910 2*GM $898
3” UFLK5910 2*GM $898
4” UFLKP106 PR $1,131

RETROFIT SOLUTIONS
No
5” UFLK5948 SY4 $1,420
6” UFLK5948 SY4 $1,420
3-way
8” UFLK5950 SY6 $1,420
12” UFLK5954 SY8 $1,493
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

UFLK5902 2*AF $898


2”
UFLK5900 GK $724
Yes
2½” UFLK5910 2*GK $898
3” UFLK5910 2*GK $898
PDC
All prices are in US Dollars (USD)

2” UFLK3100 GM $497
2½” UFLK3102 2*GM $667
3” UFLK3102 2*GM $667
No
4” UFLK3108 2*GM $542
6” UFLKP010 PR $778
2-way 8” UFLK3132 SY4 $778
UFLK3102 2*AF $667
2”
UFLK3100 GK $497
Yes 2½” UFLK3102 2*GK $667
3” UFLK3102 2*GK $667
4” UFLK3108 2*GK $542
27 Series Butterfly Valves (Pinned Shaft Type) 2” UFLK6100 GM $778
2½” UFLK6102 2*GM $898
3” UFLK6102 2*GM $898
5” UFLK6126 SY4 $1,420
No
6” UFLK6128 SY4 $1,420
8” UFLK6130 SY4 $1,420
3-way
10” UFLK6132 SY6 $1,420
12” UFLK6134 SY7 $1,459
UFLK6102 2*AF $898
2”
UFLK6100 GK $778
Yes
2½” UFLK6102 2*GK $898
3” UFLK6102 2*GK $898

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

21-53
Victaulic
Masterseal, Vic300 Series Butterfly Valves
Linkage/Actuator Selection Guide

Valve Belimo Belimo Linkage


Valve Body Model Fail-Safe Size
Configuration Linkage Actuator Series List Price
UFLK8172 AM $398
2”
UFLKP001 PR $783
UFLK8172 GM $398
2½”
UFLKP001 PR $783
UFLK8172 GM $398
3”
UFLKP001 PR $783
No UFLK8176 2*GM $534
4”
UFLKP008 PR $778
5” UFLKP013 PR $834
6” UFLKP013 PR $834
2-way 8” UFLK8188 SY4 $793
10” UFLK8190 SY5 $793
12” UFLK8190 SY6 $793
2” UFLK8174 2*AF $461
UFLK8174 2*AF $461
2½”
UFLK8172 GK $398
3” UFLK8172 GK $398
Yes
4” UFLK8176 2*GK $534
4” UFLKP008 PKR $778
Masterseal (New Style) Series Butterfly Valves 5” UFLKP013 PKR $834
6” UFLKP013 PKR $834
UFLK7400 GM $778
2”
UFLKP101 PR $1,593
UFLK7402 2*GM $823
2½”
UFLKP101 PR $1,593
3” UFLKP101 PR $1,593
No 4” UFLKP108 PR $1,131
5” UFLKP113 PR $1,140
6” UFLK7412 SY4 $1,140
8” UFLK7414 SY4 $1,842
3-way
10” UFLK7416 SY6 $1,447
12” UFLK7418 SY7 $1,824
UFLK7402 2*AF $823
RETROFIT SOLUTIONS

2”
UFLK7400 GK $778
2½” UFLK7402 2*GK $823
Yes 2½” UFLKP101 PKR $1,593
3” UFLKP101 PKR $1,593

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


4” UFLKP108 PKR $1,131
5” UFLKP113 PKR $1,140
2” UFLK3300 AM $571
2½” UFLK3308 AM $504
3” UFLK3308 GM $504

All prices are in US Dollars (USD)


No 4” UFLK3316 2*GM $557
8” UFLK3352 SY4 $846
10” UFLK3354 SY4 $854
2-way
12” UFLK3356 SY4 $784
2” UFLK3300 AF $571
2½” UFLK3308 AF $504
Yes UFLK3310 2*AF $487
3”
UFLK3308 GK $504
Vic300 (Old Style) Series Butterfly Valves
4” UFLK3316 2*GK $557
2” UFLK6300 GM $1,071
2½” UFLK6308 GM $1,071
6” UFLK6348 SY4 $1,417
No
8” UFLK6350 SY4 $1,431
10” UFLK6352 SY5 $1,504
3-way
12” UFLK6354 SY6 $1,504
UFLK6300 AF $1,071
2”
UFLK6300 GK $1,071
Yes
UFLK6310 2*AF $1,011
2½”
UFLK6308 GK $1,071

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

21-54
Specialty Retrofit Solutions for Valve Manufacturers
Belimo offers specialty linkage solutions for the manufacturers in the chart below.
Please contact technical support for a quotation.
Valve Company Butterfly Valve Series Valve Configuration
2-way
Apollo 141/143 Series
3-way
2-way
Belimo HS, HSU, HD, HDU Series
3-way
2-way
Challenger CH100 Series
3-way
2-way
Chemtrol PVC Model C Series
3-way
2-way
Dezurik BRS Series
3-way
2-way
1 L/W Series
3-way
Flowseal
2-way
3 L/W Series
3-way
2-way
FNW Figure 1000/2000 Series
3-way
2-way
Figure 7700 (Double D Shaft 2003 and Newer) Series
3-way
Gruvlok
2-way
Figure 7700 (Sheared Pin Shaft Pre 2003) Series
3-way
2-way
Hammond 61/62 Series
3-way
2-way
815 L/W Series
3-way
Jamesbury
2-way
830 L/W Series

RETROFIT SOLUTIONS
3-way
2-way
Jenkins 22XXEXJ Series
3-way
2-way
Metraflex 200 WOG Series
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

3-way
2-way
Mueller 65/66 Series
3-way
2-way
PDC 27 Series (Double D Shaft)
3-way
All prices are in US Dollars (USD)

2-way
Quartermaster 42/44 Series
3-way
2-way
Watts DBF Series (pre 2009)
3-way

Considerations:
• Every retrofit solution is available in 2-way and 3-way configurations.

• Kits do not require completed retrofit form; only the make, model, and
size of the competitor valve are required.

• Pricing and delivery vary with complexity.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

21-55
Custom Butterfly Valve Retrofit Solution Form
UFSP Series

Instructions for Completing this Form


Required tools needed a caliper, thread gauge, retrofit form, flashlight, and ladder (if applicable).

Please keep in mind that all dimensions should be taken with ALL original actuation and hardware components removed from the valve body.
Examples of dimensions A & B (Dim A and Dim B) relate to the TOP mounting holes on the butterfly valve body. These holes are usually arranged on
the body in either an “X” pattern (MOUNT STYLE 1), or a cross pattern (MOUNT STYLE 2). This information is entered on the UFSP Series Butterfly
Valve Retrofit Form in the MOUNT STYLE section. The length of the valve stem sticking out of the top of the valve body is recorded under Dim C. The
TOP mounting holes are usually drilled through the top flange, but sometimes are threaded. Enter this information on the form next to the mount style
information previously recorded.
Next is the valve stem data. The five styles of valve stems cover 98% of the butterfly valves ever produced. Examine the valve being retrofitted to establish
which shaft style matches the diagrams above. Use caution when recording these dimensions. Careless use of calipers will result in a sloppy and possibly
dysfunctional linkage system. Dim D refers to the valve stem diameter and should be measured at several points up and down as well as around the stem
itself. Dim E refers to the length of the drive surface available, whether it be a key, flatted surface, or the distance a drive hole is from the top of the stem.
There are two types of keys (Keyway-Shaft Style 4 and Woodruff Key-Shaft Style 5). Please select the key size as noted in the column “For Shaft Style 4 & 5”.
Dim F refers to the width of the drive surface. This is the most critical dimension for correct linkage operation. Please measure accordingly.
In addition, we require information about the environment and process in which this linkage system will be utilized.
The form must be completed in its entirety to guarantee the complete, perfect fit of your retrofit system. Keep in mind that retrofit kits are designed
with close-tolerance components which afford the most efficient linkage system for the facility. Measurements rounded to the nearest 1/8 or 1/16 inch
will not perform as well (sometimes not at all) as a kit designed around careful measurements using proper equipment. Our designs are typically
+.005” tolerance.

DISCLAIMER

We will do our best to provide a linkage system designed around your specifications and measurements. However, we cannot be held responsible for
linkages which do not fit as a result of incorrect data given to Belimo. We will re-work components which do not fit properly for a nominal fee.
RETROFIT SOLUTIONS

To reduce the possibility of incorrect linkage solutions, we respectfully request that you fill out the retrofit form completely and forward that
information with your order. This will serve as a double check between your valve and the actuator/linkage package designed for your application.

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


Actuation, weather shields and linkages cannot be pre-assembled at the Belimo factory prior to your receipt. The linkages are designed to be attached
onto the valve body first, then optional weather shields, and finally actuation products.
Close-off pressures are calculated using actuator torque, valve stroke, and valve area. Other factors may affect the rated close-off pressures,
including flow rates, system maintenance schedules, chemicals used in the shot feeder process, vicinity to pumps, condition of valve stem seals, and
assembly of linkage material in the field.

All prices are in US Dollars (USD)


Valves that are being considered for retrofit of actuation should be analyzed for their life expectancy before the retrofit has taken place. Valves that leak
through stem seals or casings will continue to leak with the new linkage system in place, maybe even more so. Rebuilding the packing on these valves
may be more costly than replacing the valves themselves. In some instances, older valve stem heights will require field modifications to the valve in order
to utilize the retrofit kit. Belimo takes no responsibility for the operation of these valves after they have been modified.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

21-56
Custom Butterfly Valve Retrofit Solution Form
Custom Butterfly Valve Retrofit Form UFSP Series
®

UFSP Series
MOUNT STYLE 1 MOUNT STYLE 2 MOUNT STYLE DIMENSIONS
MOUNTING
SHAFT SHAFT HOLES MOUNT STYLE
B DIM A:
DIM B:
A
A B DIM C:
MOUNTING DIM. A & B MEASURED FROM CENTER OF HOLE
VALVE VALVE C
C HOLES BODY
BODY

MOUNT STYLE 3 MOUNTING MOUNT STYLE 4


HOLES SKETCH YOUR MOUNT STYLE
USING MOUNT STYLE EXAMPLES. MOUNTING HOLES:
SHAFT
DRILLED
DIA Ø: Ex: 0.437"
A B
THREAD TAPPED
VALVE SPEC. Ex: 1/2-20
BODY C

SHAFT STYLE 4 SHAFT STYLE 6 SHAFT STYLE 8 SHAFT STYLE 9


F KEY SIZE VALVE CLOSED
D D F D
.125"
G E
.1875" F
E E G
.250"

RETROFIT SOLUTIONS
KEYWAY DOUBLE D PINNED

SHAFT STYLE 5 .3125" SHAFT STYLE 9


F SHAFT STYLE 7
F
E .375" D F D
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

.4375"
G
D H .500" E E
WOODRUFF KEY CHECK ONE HEX SQUARE CHECK ONE
All prices are in US Dollars (USD)

SHAFT STYLE
DIM D: DIM E: DIM F: DIM G: DIM H:

ACTUATOR
EXISTING ACTUATOR MODEL: _______________________ CONTROL TYPE: ON/OFF FLOATING POINT VDC PWM
FAIL SAFE: YES NO Range:_____ Range:_____
FAIL POSITION: NO NC INDOOR OUTDOOR
VOLTAGE_____

COMPANY: VALVE MANUFACTURER: 2 WAY/3 WAY:


JOB NAME: VALVE SERIES: VALVE SIZE:
PO#: VALVE MODEL: MEDIA TEMP:
PHONE: VALVE TAG/LOCATION: MEDIA TYPE:
EMAIL: QUANTITY: SYSTEM PRESSURE:

NOTE: THIS INFORMATION WILL BE UTILIZED IN THE FABRICATION OF A CUSTOM LINKAGE SYSTEM FOR YOUR VALVE REQUIREMENT; THEREFORE, IT IS ESSENTIAL THAT THE
ABOVE DIMENSIONS BE FURNISHED WITH READINGS TAKEN TO THE NEAREST .001". ANY ERRONEOUS DIMENSIONS FURNISHED WHICH RESULT IN IMPROPER FIT OF THIS LINKAGE
SYSTEM ARE NOT THE RESPONSIBILITY OF BELIMO AIRCONTROLS. ANY REWORK REQUIRED WILL RESULT IN AN EXTRA CHARGE.

CUSTOM KITS ARE DESIGNED TO YOUR UNIQUE SPECIFICATIONS AND ARE NOT RETURNABLE.
COMPANY CONTACT/DIMENSIONS PROVIDED BY: ____________________________________________________________________ DATE: ___________________

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

21-57
Custom Butterfly Valve Retrofit Solutions
Component Identification

2-way Single Actuator 2-way Dual Actuator 2-way SY / PR / PKR Actuator


Generic – Retrofit Form Required Generic – Retrofit Form Required Generic – Retrofit Form Required

VALVE COUPLING
DRIVE SHAFT DRIVE SHAFT
ACTUATOR PLATE
BRACKET
ANTI-ROTATION NUT
LOCK WASHER (4)
INDUSTRIAL
COUPLING
PIN VALVE COUPLING (WELDED)
PIN

BOLT (4)
ANTI-ROTATION NUT
SHAFT LOCK () SHAFT LOCK

BOLT (4)

BOLT (4)
VALVE STEM
BOLT (4)

ANTI-ROTATION PIN
TOP MOUNTING HOLES
NUT (4)
TOP MOUNTING HOLES
NUT (4) EXISTING VALVE BODY
VALVE STEM ANTI-ROTATION PIN
() ACTUATOR PLATE
EXISTING VALVE BODY
TOP MOUNTING HOLES VALVE STEM

LUG MOUNTING HOLES VALVE DISC


NUT (4)
VALVE DISC
EXISTING VALVE BODY

LUG MOUNTING HOLES


VALVE DISC
LUG MOUNTING HOLES

UFSP0000 $813 UFSP0008 $1,073 UFSP0020* PR, PKR, SY4 - SY8 $966
UFSP0022* SY9 - SY12 $1,637
3-way Single Actuator 3-way Dual Actuator 3-way SY / PR / PKR Actuator
Generic – Retrofit Form Required Generic – Retrofit Form Required Generic – Retrofit Form Required
RETROFIT SOLUTIONS

CLEVIS PIN (2) CLEVIS PIN (2)

OKE (2) OKE (2)


CRANK LOCK (2) CRANK LOCK (2)
DRIVE SHA T DRIVE SHA T (2)

PIN PIN (2)

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


CONNECTING CONNECTING
ROD ROD
SHA T LOCK (2) SHA T LOCK (2)
AM NUT AM NUT
VALVE COUPLING (2) OLT (4) VALVE COUPLING (2) OLT ( )

COTTER PIN (2) COTTER PIN (2)

CRANK ARM (2)


CRANK ARM (2)

All prices are in US Dollars (USD)


ACTUATOR PLATE ACTUATOR PLATE (2)

ANTI-ROTATION NUT ANTI-ROTATION NUT (2)


VALVE STEM
VALVE STEM EXISTING VALVE ANTI-ROTATION PIN (2)
ANTI-ROTATION PIN
EXISTING VALVE TOP MOUNTING HOLES
TOP MOUNTING HOLES

NUT ( )
NUT (4)

EXISTING TEE EXISTING TEE

EXISTING VALVE
EXISTING VALVE

UFSP0002 $1,073 UFSP0010 $1,169 UFSP0024* PR, PKR, SY4 - SY8 $1,705
UFSP0026* SY9 - SY12 $2,431
NOTE: 3-way bracket configuration shown is only one of many possible arrangements. Custom kits are
designed to your unique specification and are not returnable.
*Reference page 21-50 Keystone AR1/AR2 for approximate actuator sizing.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

21-58
Custom Ball Valve Retrofit Solution Form

Instructions for Completing this Form


Required tools needed a caliper, thread gauge, retrofit form, flashlight, and ladder (if applicable).

Ball valves without a mounting flange are typically not designed for installing actuation; therefore the valve design may not support modulation
outside of manual usage. Belimo does not recommend retrofitting these types of ball valves.

All dimensions should be taken with ALL original actuation and hardware components removed from the valve body.

An example using Mounting Style 3: Dimensions A & B (Dim A and Dim B) relate to the TOP mounting holes on the ball valve body. These holes
are usually arranged on the body in a “X” pattern (MOUNT STYLE 3). This information is entered on the UBSP Series Ball Valve Retrofit Form in the
MOUNT STYLE section. The length of the valve stem sticking out of the top of the valve body is recorded under Dim D and E. The TOP mounting
holes are usually drilled through the top flange, but sometimes are threaded. Enter this information on the form next to the mount style information
previously recorded.

MOUNT STYLE 3: Dimensions A & B (Dim A and Dim B) relate to the TOP mounting holes on the ball valve body. These holes are usually arranged
on the body in a “X” pattern (MOUNT STYLE 3). This information is entered on the UBSP Series Ball Valve Retrofit Form in the MOUNT STYLE
section. The length of the valve stem sticking out of the top of the valve body is recorded under Dim D and E. The TOP mounting holes are usually
drilled through the top flange, but sometimes are threaded. Enter this information on the form next to the mount style information previously
recorded.

STEM STYLE: Examine the valve being retrofitted to establish which stem style matches the diagrams. Use caution when recording these dimensions.
Dim H refers to the valve stem diameter and should be measured at several points up and down as well as around the stem itself. Dim E refers to
the length of the drive surface available, whether it is a key or flatted surface. Dim F refers to the width of the drive surface or the distance across
the flats. This is the most critical dimension for correct linkage operation. Please measure accordingly. Lastly please specify the desired actuator
orientation in reference to the valve body using the ports as reference, i.e. over the “A” port etc. We have also includes an ISO-5211 standard
dimension chart for reference. If the valve is labeled please specify its “F” number so that we may confirm the dimensions per the ISO spec.

In addition, we require information about the environment and process in which this linkage system will be utilized, as well as the frequency of use
the current actuator runs. This will help to ensure the longevity of the new linkage and actuator. Having the prior actuator spec and model will help.

RETROFIT SOLUTIONS
The form must be completed in its entirety to guarantee the complete, perfect fit of your retrofit system. Keep in mind that retrofit kits are designed
with close-tolerance components which afford the most efficient linkage systems. Measurements rounded to the nearest 1/8 or 1/16 inch will not
perform as well (sometimes not at all) as a kit designed around careful measurements using proper equipment. Our designs are typically +.005”
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

tolerance.
DISCLAIMER

We will do our best to provide a linkage system designed around your specifications and measurements. However, we cannot be held responsible
All prices are in US Dollars (USD)

for linkages which do not fit as a result of incorrect data given to Belimo. We will re-work components which do not fit properly for a nominal fee.
To reduce the possibility of incorrect linkage solutions, we respectfully request that you fill out the retrofit form completely and forward that
information with your order. This will serve as a double check between your valve and the actuator/linkage package designed for your application.
Actuation, weather shields and linkages cannot be pre-assembled at the Belimo factory prior to your receipt. The linkages are designed to be
attached onto the valve body first, then optional weather shields, and finally actuation products.
Close-off pressures are calculated using actuator torque, valve stroke, and valve area. Other factors may affect the rated close-off pressures,
including flow rates, system maintenance schedules, chemicals used in the shot feeder process, vicinity to pumps, condition of valve stem seals,
and assembly of linkage material in the field.
Valves that are being considered for retrofit of actuation should be analyzed for their life expectancy before the retrofit has taken place. Valves that leak
through stem seals or casings will continue to leak with the new linkage system in place, maybe even more so. Rebuilding the packing on these valves
may be more costly than replacing the valves themselves. In some instances, older valve stem heights will require field modifications to the valve in
order to utilize the retrofit kit. Belimo takes no responsibility for the operation of these valves after they have been modified.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

21-59
Custom Ball Valve Retrofit Solution Form
Custom Ball Valve Retrofit Form
UBSP Series
®

UBSP Series
MOUNT STYLE 1 MOUNT STYLE 2 MOUNT STYLE 3
I
MOUNTING HOLE
CENTER OF STEM
D B B
TO END OF STOP

E E A
A A

C E MOUNTING HOLE MOUNTING HOLE

MOUNT STYLE 4 MOUNT STYLE DIMENSIONS ISO STANDARD


SKETCH YOUR MOUNT STYLE USING EXAMPLES ABOVE
ISO BOLT BOLT CHECK

MOUNT STYLE MOUNTING HOLES:


SQUARE SIZE Ø ONE

F03 1.002 M5
DIM A: DRILLED F04 1.169 M5
DIA Ø: F05 1.392 M6
DIM B: F07 1.949 M8
DIM C: F10 2.840 M10
TAPPED F12 3.480 M12
DIM D: THREAD F14 3.879 M16
SPEC. F16 4.593 M20
DIM E:
F25 7.071 M16
DIM. A & B MEASURED FROM CENTER OF HOLE

STEM STYLE 1 STEM STYLE 2 STEM STYLE 3


SQUARE DRIVE
J DIAMETER
OF STEM NUT ON STEM NO NUT J DIAMETER
OF STEM

H
I LARGEST AREA
TO CLEAR OR NUT

# OF NUTS: ______ VALVE IN CLOSED POSITION


RETROFIT SOLUTIONS

DIAGONAL PARALLEL

H G F H
ACROSS
FLATS

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


G TOP OF G TOP OF
NUT TO NUT TO
TOP OF
F
TOP OF
STEM F STEM

All prices are in US Dollars (USD)


STEM STYLE
DIM F: DIM G: DIM H: DIM I: DIM J:

ACTUATOR ACTUATOR
EXISTING ACTUATOR MODEL: _______________________ CONTROL TYPE: ON/OFF FLOATING POINT VDC PWM ORIENTATION:
FAIL SAFE: YES NO Range:_____ Range:_____ A AB
FAIL POSITION: NO NC INDOOR OUTDOOR
FREQUENCY OF OPERATION (specify how often): DAILY_____ WEEKLY_____ MONTHLY_____ VOLTAGE: _____
B

COMPANY: VALVE MANUFACTURER: 2 WAY/3 WAY:


JOB NAME: VALVE SERIES: VALVE SIZE:
PO#: VALVE MODEL: MEDIA TEMP:
PHONE: VALVE TAG/LOCATION: MEDIA TYPE:
EMAIL: QUANTITY: SYSTEM PRESSURE:

NOTE: THIS INFORMATION WILL BE UTILIZED IN THE FABRICATION OF A CUSTOM LINKAGE SYSTEM FOR YOUR VALVE REQUIREMENT; THEREFORE, IT IS ESSENTIAL THAT THE
ABOVE DIMENSIONS BE FURNISHED WITH READINGS TAKEN TO THE NEAREST .001". ANY ERRONEOUS DIMENSIONS FURNISHED WHICH RESULT IN IMPROPER FIT OF THIS LINKAGE
SYSTEM ARE NOT THE RESPONSIBILITY OF BELIMO AIRCONTROLS. ANY REWORK REQUIRED WILL RESULT IN AN EXTRA CHARGE.

CUSTOM KITS ARE DESIGNED TO YOUR UNIQUE SPECIFICATIONS AND ARE NOT RETURNABLE.
COMPANY CONTACT/DIMENSIONS PROVIDED BY: ____________________________________________________________________ DATE: ___________________

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

21-60
Custom Ball Valve Retrofit Solutions
Component Identification

2-way/3-way Single Actuator 2-way/3-way Dual Actuator


Generic – Retrofit Form Required Generic – Retrofit Form Required
BUSHING ACTUATOR PLATE
NUT
DRIVE SHAFT

ROLL PIN BOLT

EXTENSION

BOLT

ANTI-ROTATION PIN

BUSHING

NUT
NYLON WASHER
ROLL PIN
ACTUATOR PLATE
DRIVE SHAFT
VALVE COUPLING
BOLT
BUSHING NUT
ZM0259

ACTUATOR

ZM0260
MOUNTING NYLON
PLATE WASHER
BRACKET

NUT
VALVE EXTENSION
COUPLING

BOLT

BOLT
ANTI-ROTATION
PIN
LOCK WASHER

BOLT
NUT ANTI-ROTATION
PIN MOUNTING
BRACKET
LOCK
WASHER
NUT
NUT

UBSP0004 $775 UBSP0006 $1,052

Industrial Electronic 2-way/3-way


Generic – Retrofit Form Required

RETROFIT SOLUTIONS
MOUNTING
BRACKET
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

SPLIT LOCK
WASHER

BOLT
All prices are in US Dollars (USD)

SY CPL/INTERFACE

VALVE COUPLING
ZM0271

BOLT

LOCK WASHER

UBSP0008 PR, PKR, SY4 - SY6 $962 NUT

UBSP0012 SY7-SY9 $1,614


Custom kits are designed to your unique specification and are not returnable.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

21-61
Increasing
Performance and
Efficiency

UBLK1000 Series Zone Valve Retrofit Solution


The new UBLK series retrofit kits are designed to replace existing actuators on TACO zone
valves, Schneider VBB ball valves, or Erie VM zone valves with the Belimo compact CQ
non fail-safe or CQK electronic fail-safe actuator. These replacement solutions restore
service without the removal of the valve, saving downtime, increasing performance, and
efficiency backed with a 5-year warranty.

Discover the advantages


www.belimo.us
22
APPENDIX
Quality, Reliability, Ease of
Doing Business
• Damper actuator and valve sizing.
• Valve quotation form.
• Terms and conditions.
• Actuator and valve specifications.
• Belimo platinum distributors.

Alan Kovacs, Vice President,


Quality and Customer Service, Americas
How to Select a Damper Actuator

ACTUATOR REQUIREMENTS APPLICATION DATA


The “10 questions” method for sizing and selection shown below is
recommended as the best method for your actuation requirements. 6 Is fail-safe
actuation
Use the “Application Data” column in this chart as a worksheet to help
in the selection process. required?
❑ Yes
APPLICATION INFO APPLICATION DATA ❑ No
Consider the application. Is the
1 What is the
total area of
actuator and/or damper exposed
to outside air? If yes, use fail-safe
the damper? actuator.

sq.ft.
7 What is
the supply
Do you need
a step down
voltage to transformer? ❑ 24 VAC
2 Opposed blade
or
L” x W” = Total sq.
inches/144 = total sq. feet the actuator? If replacing an oil ❑ 120 VAC
• 24 VAC/DC immersed gear
Parallel blade Opposed Blade train actuator, is the transformer in the
construction? w/o seals 3 in-lbs/sq. ❑ Opposed Blade
• 120 VAC
defective actuator? You may need to
❑ 230 VAC
feet* • 230 VAC purchase one.
single phase

8
Opposed Blade What is • 2 position ❑ On/Off
w/ seals 5 in-lbs/sq. feet
the control • Floating point ❑ Floating Point
Parallel Blade signal to the • Modulating
w/o seals 4 in-lbs/sq. feet actuator? ❑ 2-10 VDC
• Sequencing
❑ 0.5-10 VDC
Parallel Blade ❑ Parallel Blade • “Non-standard”
w/ seals 7 in-lbs/sq. feet voltage signals ❑ 4-20 mA
*Less than 1,000 feet per This will be a critical component to ❑ PWM____
minute the selection of an actuator. Consider range
the …MFT actuator product range and
❑ Other (MFT)
3 Are there blade
and edge seals
This will impact
the proper
the flexibility of its application.

on the damper?
selection as the
seals add resistance ❑ Yes 9 Can you direct
couple to a
Direct-
coupling has
requiring more torque. damper shaft? become the ❑ Yes
If unknown, use ❑ No industry
a worst case standard. ❑ No, see
scenario, parallel Some retrofit
blade with seals. applications
accessories

U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


do not allow direct coupling. Refer to page
4 For the damper
in question,
If this information
is not available
the Belimo “Mounting & Methods
Guide” for application details.
refer to the
what does the
manufacturer
“typical damper
requirements and 10 Are there
additional
K7-2
KH-AFB

in-lbs/sq.ft. ❑ No

All prices are in US Dollars (USD)


specify as the sizing” chart
below. accessories
torque rating? required?
PA… SA…

❑ Yes, see
accessories
5 What is the air For example, some applications require
APPENDIX

velocity, static _______W.G. the addition of an auxiliary switch for section or


pressure, or proof of position; a retrofit application actuator
_______CFM may require an additional mounting series for
design CFM? bracket and linkage kit. We advise that
_______FPM details
Systems above 1,000 FPM you identify these needs prior to leaving
require additional actuator torque the job site or ordering products.

TYPICAL DAMPER REQUIREMENTS AND SIZING


Square Damper (with square shape): ft2 = h x w /144; (h= height, w= width, in inches)
EXAMPLE: Damper Area (8 ft ) x Rated Torque Loading of Damper (4 in-lbs/ft2) = Total in-lbs Required (32 in-lbs) Belimo LF 35 in-lbs/ LM 45 in-lbs actuators
2

Torque Loading in-lbs/ft2


Damper Blade Type < 1000 FPM 1000-2500 FPM 2500-3500 FPM
Parallel blade/edge seals 7 (Typical) 10.5 14
Opposed blade/edge seals 5 (Typical) 7.5 10
SQUARE

Parallel blade/no edge seals 4 6 8


Opposed blade/no edge seals 3 4.5 6
Round 10 14 20

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

22-2
How to Select a Damper Actuator

TYPICAL DAMPER REQUIREMENTS AND SIZING EXAMPLE:

APPLICATION REQUIREMENTS SQUARE DAMPER ROUND DAMPER


Damper Length 24"
Damper Width 12"
Damper (Round) 12"
Blade Type Opposed Round
Edge Seals Edge Seals
Design CFM 1800 CFM 700 CFM
Fail-Safe Yes Yes
Supply Voltage 24 Volt 24 Volt
Control Signal 2-10 VDC 2-10 VDC
CALCULATIONS
Damper Area (sq. inches) 24" x 12" = 288 in2 πr² =113.04 in2
Damper Area (sq. feet)* 288 in2 x 1ft/12 in x 1ft/12 in = 2 ft2 113.04 in2 / 1ft/12in x 1ft/12in= 0.785 ft2
Velocity 1800 ft3/min / 2 ft2 = 900 ft/min 700 ft3/min / .785 ft2 = 892 ft/min
See chart under <1000 FPM (ft/min) See chart under <1000 FPM (ft/min)
Rated Torque Loading (in-lbs/ft2)** Select 5 in-lbs/ft2 for Opposed Blade/Edge Seals Select 10 in-lbs/ft2 for Round Damper
EXAMPLE EQUATION *Damper Area (sq. ft) x **Rated Torque Loading of Damper (in-lbs/ft2) = Total in-lbs Required
2 ft2 x 5 in-lbs/ft2 = 10 in-lbs 0.785 ft2 x 10 in-lbs/ft2 = 7.85 in-lbs
Belimo LF24-SR US @ 35 in-lbs Belimo LF24-SR US @ 35 in-lbs

CONTROL SIGNAL OVERVIEW

Belimo actuators are compatible with many control inputs and all direct digital control (DDC) systems. There are many signals to select from
with today’s controllers.

On/Off or Open-Close: The actuator is able to drive either to its full Phasecut: An actuator drives depending on the power result of a
clockwise (CW) position, or to its full counter-clockwise (CCW) remaining wave. This signal type cuts a portion of an AC sine wave
position. and the actuator recognizes this signal as a modulating movement.
See actuator model AFB24-PC.
3-point, Tri-State, Floating Point: The actuator has both clockwise
(CW) and counter-clockwise (CCW) control inputs. One drives the
U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

actuator to its CW, the other to its CCW position. If there is no signal
(Null point) on either input the actuator simply stays in its last
position.
All prices are in US Dollars (USD)

Modulating (Proportional) Control: The actuator drives to its control


signal input throughout its angle of rotation. This control type is
usually a variation of VDC with typical ranges of 0.5-10 VDC and
Multi-Functional Technology (MFT): This technology was developed

APPENDIX
2-10 VDC.
by Belimo for incorporation into our damper and valve actuators.
It is common to also have a 4-20 mA output from a controller. This MFT provides the ability to program certain characteristics of the
can be very easily converted to 2-10 VDC with a 500 Ω resistor. actuators. Some of the key characteristics to change are:

Pulse Width Modulation (PWM): The actuator drives to a specified CONTROL INPUT
position according to a pulse duration, the “length” of signal. The Selectable on/off, VDC, PWM or floating point
pulse can originate from a dry contact closure or a triac sink or MOTION VALUES
source controller. An example of PWM control: Selectable running time adjustment
Time base: 0 to 10 seconds FEEDBACK
Output pulse: 5 seconds Selectable feedback values

Actuator position: 50% 0-135 Ω: The actuator drives to a modulating position proportional to
the ohm signal of the controller. See actuator model AFB24-MFT95.
See -MFT model actuators.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

22-3
Valve Sizing – Water Applications

PRESSURE DEPENDENT, ON/OFF APPLICATION PRESSURE DEPENDENT, MODULATING APPLICATION


APPLICABLE PRODUCTS APPLICABLE PRODUCTS
CCV, HTCCV, ZONE, GLOBE, BALL, QCV CCV, HTCCV, ZONE, GLOBE, BALL, QCV

REQUIRED INFORMATION REQUIRED INFORMATION


FOR SIZING: FOR SIZING:
flow in GPM flow in GPM
∆P (if none given, utilize 1 psi) ∆P (if none given, utilize 3-5 psi)

FOR SELECTION: FOR SELECTION:


2-way or 3-way valve 2-way or 3-way valve
pipe size pipe size
media temperature media temperature
fail-safe or non fail-safe fail-safe or non fail-safe
required close-off pressure (COP) required close-off pressure (COP)
voltage requirement voltage requirement
ambient temperature ambient temperature
required accessories required accessories

EQUATIONS USED EQUATIONS USED

   
2 2
Q* G Q* G Q* G Q* G
Cv   P Cv   P
P Cv P Cv
Cv = 50* 1  Cv
required Cv = 50* 1 Cv
required
Cv  50 Cv  50
Q = flow
1 in Gallons per Minute Q = flow
1 in Gallons per Minute
G = Specific gravity of fluid (estimated as 1 for water systems) G = Specific gravity of fluid (estimated as 1 for water systems)
∆P = differential pressure over valve (deltaP) – stated in psi ∆P = differential pressure over valve (deltaP) – stated in psi

PROCEDURE PROCEDURE
1) Calculate Cv 1) Calculate Cv
2) Choose valve type (CCV, Zone, etc) 2) Choose valve type (CCV, Zone, etc)
3) Choose valve model number that has closest Cv rating 3) Choose valve model number that has closest Cv rating
(normally round down unless maximum ∆P for project is exceeded) (normally round down unless maximum ∆P for project is exceeded)
a. Refer to section 8 for QCV a. Refer to section 8 for QCV
b. Refer to section 11 for CCV (Fp correction required)

U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


b. Refer to section 11 for CCV (Fp correction required)
c. Refer to section 12 for HTCCV c. Refer to section 12 for HTCCV
d. Refer to section 10 for Zone valves d. Refer to section 10 for Zone valves
e. Refer to section 15 for Globe valves e. Refer to section 15 for Globe valves
f. Refer to sections 13 and 14 for Ball valves (Fp correction required) f. Refer to sections 13 and 14 for Ball valves (Fp correction required)

All prices are in US Dollars (USD)


NOTE: If valve selection requires piping correction factor (Fp), calculate Cv NOTE: If valve selection requires piping correction factor (Fp), calculate Cv
based on chart provided in section that shows appropriate Cv for pipe size based on chart provided in section that shows appropriate Cv for pipe size
selected. In general, do not select a valve less than ½ of the line size selected. In general, do not select a valve less than ½ of the line size
APPENDIX

4) Calculate actual ∆P based upon Cv of valve selected 4) Calculate actual ∆P based upon Cv of valve selected
5) If calculated ∆P is within project specified limits, proceed with actuator 5) If calculated ∆P is within project specified limits, proceed with actuator
selection selection
6) If #5 is no, need to select a valve with a higher/lower Cv 6) If #5 is no, need to select a valve with a higher/lower Cv
7) Select actuator based upon selection parameters above 7) Select actuator based upon selection parameters above
8) Based upon actuator/valve selection, verify close-off pressure (COP) meets 8) Based upon actuator/valve selection, verify close-off pressure (COP) meets
project requirements project requirements

EXAMPLE OF CV CALCULATION EXAMPLE OF CV CALCULATION

 
i.e. GPM is 50 2 i.e. Pressure drop through the coil is 3 psi, then the pressure drop across the
i.e. SG is 1 Q* G Q* G valve should be approximately 3 psi. Let us use 4 psi for example.
Cv   P

 
i.e. ∆P = 1 psi P Cv i.e. GPM is 50 2
i.e. SG is 1 Q* G Q* G
Cv = 50 GPM * sqrt of SG1/sqrt of 1 psi 50* 1  Cv   P
Cv  50 i.e. ∆P = 4 psi P Cv
Cv = 50 GPM/1 = 50 1
Cv = 50 GPM * sqrt of SG1/sqrt of 4 psi 50* 1
Cv   25
Cv = 50 GPM/2 = 25 4

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

22-4
Valve Sizing – Water Applications

PRESSURE INDEPENDENT, ON/OFF, FLOATING APPLICATION PRESSURE INDEPENDENT, MODULATING APPLICATION


APPLICABLE PRODUCTS APPLICABLE PRODUCTS
ePIV, ENERGY VALVE, PIQCV ePIV, ENERGY VALVE, PIQCV

REQUIRED INFORMATION REQUIRED INFORMATION


FOR SIZING: FOR SIZING:
flow in GPM flow in GPM
line size line size
FOR SELECTION: FOR SELECTION:
2-way valves only 2-way valves only
pipe size pipe size
media temperature media temperature
fail-safe or non fail-safe fail-safe or non fail-safe
required close-off pressure (COP) required close-off pressure (COP)
voltage requirement voltage requirement
ambient temperature ambient temperature
required accessories required accessories

EQUATIONS USED EQUATIONS USED


No equations are required. Choose the valve that has the closest GPM to the No equations are required. Choose the valve that has the closest GPM to the
requirement and round up to next available flow. requirement and round up to next available flow.

PROCEDURE PROCEDURE
1) Obtain required GPM 1) Obtain required GPM
2) Choose valve model number that has closest GPM rating (round up) 2) Choose valve model number that has closest GPM rating (round up)
• Refer to section 6 for ePIV • Refer to section 6 for ePIV
• Refer to section 5 for Energy Valve • Refer to section 5 for Energy Valve
• Refer to section 7 for PIQCV • Refer to section 7 for PIQCV
3) Verify that valve size is not larger than 2 times pipe size and in general, do 3) Verify that valve size is not larger than 2 times pipe size and in general, do
not select a valve less than 2 times the line size not select a valve less than 2 times the line size
4) Select actuator based upon selection parameters above 4) Select actuator based upon selection parameters above
5) Based upon actuator/valve selection, verify close-off pressure (COP) meets 5) Based upon actuator/valve selection, verify close-off pressure (COP) meets
project requirements project requirements
U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

EXAMPLE OF SELECTION EXAMPLE OF SELECTION


87 GPM is needed – choose 90 GPM valve P2200S-900 87 GPM is needed – choose 90 GPM valve P2200S-900
All prices are in US Dollars (USD)

APPENDIX

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

22-5
Valve Sizing – Steam Applications
Low Pressure Steam

LOW PRESSURE STEAM (15 PSI AND UNDER), ON/OFF APPLICATION

APPLICABLE PRODUCTS PROCEDURE


HTCCV, GLOBE, VS/VSS/V BALL, SHP BUTTERFLY 1) Calculate Cv using 10% inlet gauge pressure as h (differential pressure)
2) If this is a 1/3 – 2/3 application, you will select 2 valves. The first valve will be
REQUIRED INFORMATION rated for 1/3 of the total flow (1/3 of required Cv rating) and the second valve
will be rated for 2/3 of the total flow (2/3 of required Cv rating).
FOR SIZING:
3) Choose valve type (Ball, Globe, HTCCV, etc)
flow in lb/hr
∆P (if none given, 10% psi or line size valve) 4) Choose valve model number that has closest Cv rating (normally round down
Is it a 1/3 – 2/3 application? unless maximum ∆P for project is exceeded)
a. Refer to section 12 for HTCCV
FOR SELECTION:
b. Refer to section 15 for Globe valves
2-way valve only
c. Refer to sections 13 and 14 for Ball valves (Fp correction required)
pipe size
d. Refer to section 16 for Butterfly valves
media temperature
fail-safe or non fail-safe actuation NOTE: If valve selection requires piping correction factor (Fp), calculate Cv
required close-off pressure (COP) based on chart provided in section that shows appropriate Cv for pipe size
voltage requirement selected. In general, do not select a valve less than ½ of the line size
ambient temperature 5) Calculate actual ∆P based upon Cv of valve selected
required accessories 6) If calculated ∆P is within project specified limits, proceed with actuator
selection
EQUATIONS USED 7) If #6 is no, need to select a valve with a higher/lower Cv
8) Select actuator based upon selection parameters above
Q
Cv = 9) Based upon actuator/valve selection, verify close-off pressure (COP) meets
3 * h *P o
project requirements
C Q
Cvv = = Valve coefficient
= 51.25 of flow
Q =3#/hr * h *P
steam
o
h = Pressure drop across open valve EXAMPLE OF Cv CALCULATION
– use 10% inlet pressure for on/off applications Q = FLOW RATE Q = 1000 #/hr
Po = Outlet pressure in psia = P1-h
P1 = Absolute inlet pressure = gauge pressure (psig) + 14.7 Inlet psi = 15 psi
h = 10% (inlet psi) h = 0.10 (15) = 1.5
Po = (inlet psi + 14.7) – h Po = (15 + 14.7) – 1.5 = 28.2
Q
Cv =
3 * h *P o
Cv = 1000/(3*sqrt[1.5*28.2])
Q
Cv = 1000/(3*6.50) Cv = = 51.25
Cv = 1000/19.51 3 * h *P o

U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


Required Cv = 51.25

All prices are in US Dollars (USD)


APPENDIX

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

22-6
Valve Sizing – Steam Applications
Low Pressure Steam

LOW PRESSURE STEAM, (15 PSI AND UNDER) MODULATING APPLICATION

APPLICABLE PRODUCTS PROCEDURE


HTCCV, GLOBE, VS/VSS/V BALL, SHP BUTTERFLY 1) Calculate Cv using 80% inlet gauge pressure as h (differential pressure)
2) If this is a 1/3 – 2/3 application, you will select 2 valves. The first valve will be
REQUIRED INFORMATION rated for 1/3 of the total flow (1/3 of required Cv rating) and the second valve
will be rated for 2/3 of the total flow (2/3 of required Cv rating).
FOR SIZING:
3) Choose valve type (Ball, Globe, HTCCV, SHP Butterfly, etc)
flow in lb/hr
∆P (if none given, 80% psi of inlet pressure) 4) Choose valve model number that has closest Cv rating (normally round down
Is it a 1/3 – 2/3 application? unless maximum ∆P for project is exceeded)
a. Refer to section 12 for HTCCV
FOR SELECTION:
b. Refer to section 15 for Globe valves
2-way valve only
c. Refer to sections 13 and 14 for Ball valves
pipe size
d. Refer to section 16 for Butterfly valves
media temperature
fail-safe or non fail-safe actuation NOTE: If valve selection requires piping correction factor (Fp), calculate Cv
required close-off pressure (COP) based on chart provided in section that shows appropriate Cv for pipe size
voltage requirement selected. In general, do not select a valve less than ½ of the line size
ambient temperature 5) Calculate actual ∆P based upon Cv of valve selected
required accessories 6) If calculated ∆P is within project specified limits, proceed with actuator
selection
EQUATIONS USED 7) If #6 is no, need to select a valve with a higher/lower Cv
8) Select actuator based upon selection parameters above
Q
Cv = 9) Based upon actuator/valve selection, verify close-off pressure (COP) meets
3 * h *P o
project requirements
C Q
Cv = Valve coefficient
v = = 22.9 of flow
Q =3 *#/hr
h *P
steam
o
h = Pressure drop across open valve – use 80% of inlet pressure for
EXAMPLE OF Cv CALCULATION
modulating applications if inlet is under 15 psi Q = FLOW RATE Q = 1000 #/hr
Po = Outlet pressure in psia = P1-h
P1 = Absolute inlet pressure = gauge pressure (psig) + 14.7 Inlet psi = 15 psi
h = 80% (inlet psi) h = 0.80 (15) = 12
Po = (inlet psi + 14.7) – h Po = (15 + 14.7) – 12 = 17.7
Q
Cv =
3 * h *P o
Cv = 1000/(3*sqrt[12*17.7])
Q
Cv = 1000/(3*14.6) Cv = = 22.9
3 * h *P o
Cv = 1000/43.7
U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

Required Cv = 22.9
All prices are in US Dollars (USD)

APPENDIX

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

22-7
Valve Sizing – Steam Applications
Medium/High Pressure Steam

MEDIUM/HIGH PRESSURE STEAM, (ABOVE 15 PSI), ON/OFF APPLICATION

APPLICABLE PRODUCTS PROCEDURE


GLOBE, VS/VSS/V BALL, SHP BUTTERFLY 1) Calculate Cv using 10% inlet pressure as h (differential pressure)
2) If this is a 1/3 – 2/3 application, you will select 2 valves. The first valve will be
REQUIRED INFORMATION rated for 1/3 of the total flow (1/3 of required Cv rating) and the second valve
will be rated for 2/3 of the total flow (2/3 of required Cv rating).
FOR SIZING:
3) Choose valve type (Ball, Globe, etc)
flow in lb/hr
∆P (if none given, 10% psi or line size valve) 4) Choose valve model number that has closest Cv rating (normally round down
Is it a 1/3 – 2/3 application? unless maximum ∆P for project is exceeded)
a. Refer to section 15 for Globe valves
FOR SELECTION:
b. Refer to sections 13 and 14 for Ball valves
2-way valve only
b. Refer to section 16 for Butterfly valves
pipe size
media temperature NOTE: If valve selection requires piping correction factor (Fp), calculate Cv
fail-safe or non fail-safe actuation based on chart provided in section that shows appropriate Cv for pipe size
required close-off pressure (COP) selected. In general, do not select a valve less than ½ of the line size
voltage requirement 5) Calculate actual ∆P based upon Cv of valve selected
ambient temperature 6) If calculated ∆P is within project specified limits, proceed with actuator
required accessories selection
7) If #6 is no, need to select a valve with a higher/lower Cv
EQUATIONS USED 8) Select actuator based upon selection parameters above
Q 9) Based upon actuator/valve selection, verify close-off pressure (COP) meets
Cv = project requirements
3 * h *P o
C Q
Cv = Valve coefficient
v = = 23.41 of flow
Q =3#/hr steam
* h *P o EXAMPLE OF Cv CALCULATION
h = Pressure drop across open valve
Q = FLOW RATE Q = 1000 #/hr
– use 10% inlet pressure for on/off applications
Po = Outlet pressure in psia = P1-h Inlet psi = 40 psi
P1 = Absolute inlet pressure = gauge pressure (psig) + 14.7
h = 10% (inlet psi) h = 0.10 (40) = 4
Po = (inlet psi + 14.7) – h Po = (40 + 14.7) – 4 = 50.7
Q
Cv =
3 * h *P o
Cv = 1000/(3*sqrt[4*50.7])
Cv = 1000/(3*14.3) Q
Cv = = 23.41
Cv = 1000/42.7 3 * h *P o

U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


Required Cv = 23.42

All prices are in US Dollars (USD)


APPENDIX

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

22-8
Valve Sizing – Steam Applications
Medium/High Pressure Steam

MEDIUM/HIGH PRESSURE STEAM, (ABOVE 15 PSI), MODULATING APPLICATION

APPLICABLE PRODUCTS PROCEDURE


1) Calculate Cv using 42% absolute inlet pressure as h (differential pressure)
GLOBE, VS/VSS/V BALL, SHP BUTTERFLY
2) If this is a 1/3 – 2/3 application, you will select 2 valves. The first valve will be
rated for 1/3 of the total flow (1/3 of required Cv rating) and the second valve
REQUIRED INFORMATION will be rated for 2/3 of the total flow (2/3 of required Cv rating).
FOR SIZING: 3) Choose valve type (Ball, Globe, etc)
flow in lb/hr 4) Choose valve model number that has closest Cv rating (normally round down
∆P (if none given, 42% psi of absolute inlet pressure) unless maximum ∆P for project is exceeded)
Is it a 1/3 – 2/3 application?
a. Refer to section 15 for Globe valves
FOR SELECTION: b. Refer to sections 13 and 14 for Ball valves
2-way valve only c. Refer to section 16 for Butterfly valves
pipe size NOTE: If valve selection requires piping correction factor (Fp), calculate Cv
media temperature based on chart provided in section that shows appropriate Cv for pipe size
fail-safe or non fail-safe actuation selected. In general, do not select a valve less than ½ of the line size
required close-off pressure (COP)
5) Calculate actual ∆P based upon Cv of valve selected
voltage requirement
ambient temperature 6) If calculated ∆P is within project specified limits, proceed with actuator
required accessories selection
7) If #6 is no, need to select a valve with a higher/lower Cv
EQUATIONS USED 8) Select actuator based upon selection parameters above
9) Based upon actuator/valve selection, verify close-off pressure (COP) meets
Q project requirements
Cv =
3 * h *P o
C Q
Cvv = = Valve coefficient
= 12.35 of flow EXAMPLE OF Cv CALCULATION
Q =3#/hr steam
* h *P o
h = Pressure drop across open valve – use 42% of absolute inlet pressure for Q = FLOW RATE Q = 1000 #/hr
modulating applications
Pi = inlet psi Pi = 40 psi
h= 0.42(Pi+14.7)
Po = Outlet pressure in psia = P1-h h = pressure drop across open valve – use 42% of absolute
P1 = Absolute inlet pressure = gauge pressure (psig) + 14.7 inlet pressure for modulating applications
h = 0.42 (40 + 14.7) = 22.97
Po = (inlet pressure in psia + 14.7) – h
Po = (40 + 14.7) – 22.97 = 31.73
Q
Cv =
3 * h *P o
Cv = 1000/(3*sqrt[22.97*31.73])
U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

Q
Cv = 1000/(3*26.99) Cv = = 12.35
Cv = 1000/80.97 3 * h *P o

Required Cv = 12.35
All prices are in US Dollars (USD)

APPENDIX

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

22-9
Valve Sizing – Water Applications
Velocity Method

PRESSURE DEPENDENT, ON/OFF APPLICATION

APPLICABLE PRODUCTS PROCEDURE


Butterfly Valve - HD/L Series 1) To select the proper valve, find required GPM on the velocity chart on page
Butterfly Valve Grooved - VIC Series 16-6. (Verify pipe velocity. HVAC design is typically from 4 ft/sec to 10 ft/sec.)
Butterfly Valve High Performance - SHP Series 2) Choose valve that does not exceed 12 ft/sec for the HD/L series, 20 ft/sec for
the VIC series or 32 ft/sec for the SHP series.
REQUIRED INFORMATION 3) Verify valve selection is not too large or small for the pipe size.
4) Verify Close-off Pressure (COP) is sufficient for the application.
FOR SIZING:
flow in GPM
pipe size NOTES
velocity
1) Most butterfly valves are line size and piping geometry is not considered. If
FOR SELECTION: valve size must be reduced, a recommendation is to select a valve only one
2-way or 3-way valve size less than the pipe. Do not exceed valve type fluid velocity limits.
pipe size 2) For a two-position Butterfly valve, the maximum opening for flow should be at
media temperature 90° open.
fail-safe or non fail-safe
3) Determine the close-off rating. Full rated valves have a close-off rating
required close-off pressure (COP)
equivalent to the valve body rating (most are 200 psi), with the exception of
voltage requirement
150 psi close-off for the 14” Butterfly valves and above. See Butterfly
ambient temperature
selection models for the ratings.
required accessories
4) Determine the type of actuation for your application involved.
5) Consult Belimo Customer Service for Butterfly applications involving steam,
EQUATIONS USED
high velocity requirements, etc.
No equations are used. Use Velocity Chart on page 16-6 of the Butterfly
Valve section. EXAMPLE
Application requires a 2-way, 400 GPM Butterfly valve, a valve of 4” minimum
would be selected. The 4” valve at 12 ft/second would be able to withstand a
capacity of 470 GPM, without damage to the liner.

U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


All prices are in US Dollars (USD)
APPENDIX

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

22-10
Valve Sizing – Water Applications
Using Velocity Method

PRESSURE DEPENDENT, MODULATING APPLICATION

APPLICABLE PRODUCTS PROCEDURE

Butterfly Valve - HD/L Series 1) Calculate Cv


Butterfly Valve Grooved - VIC Series 2) Choose valve model number that has closest Cv rating at 60° open (normally
Butterfly Valve High Performance - SHP Series round down unless maximum ∆P for project is exceeded.)
2) Choose valve that does not exceed 12 ft/sec for the HD/L series, 20 ft/sec for
REQUIRED INFORMATION the VIC series or 32 ft/sec for the SHP series.
FOR SIZING: FOR SELECTION: 3) Verify valve selection is not too large or small for the pipe size.
flow in GPM 2-way or 3-way valve 4) Verify Close-off Pressure (COP) is sufficient for the application.
∆P (if none given, utilize 4-5 psi) pipe size
pipe size media temperature
velocity fail-safe or non fail-safe NOTES
required close-off pressure (COP) 1) Most butterfly valves are line size and piping geometry is not considered. If
voltage requirement valve size must be reduced, a recommendation is to select a valve only two
ambient temperature sizes less than the pipe. Do not exceed valve type fluid velocity limits.
required accessories
2) For a modulating 2-way Butterfly valve, the maximum opening for flow should
be at 60° open.
EQUATIONS USED 3) Determine the close-off rating. Full rated valves have a close-off rating

 
2 equivalent to the valve body rating (most are 200 psi), with the exception of
Q* G Q* G 150 psi close-off for the 14” Butterfly valves and above. Refer to Butterfly
Cv   P
P Cv models for ratings.
50* 1  4) Determine the type of actuation for your application involved.
Cv = required C50v 5) Consult Belimo Customer Service for Butterfly applications involving steam,
Q = 1 in Gallons per Minute
flow high velocity requirements, etc.
G = Specific gravity of fluid (estimated as 1 for water systems)
∆P = differential pressure over valve (deltaP) – stated in psi
EXAMPLE OF CV CALCULATION
i.e. Pressure drop through the coil is 4 psi, then the pressure drop across the
valve should be approximately 4 psi. Let us use 4 psi for example.
i.e. GPM is 400

 
2
i.e SG is 1 Q* G Q* G
i.e. ∆P = 4 psi Cv   P
P Cv
400* 1
Cv = 400 GPM * sqrt of SG1/sqrt of 4 psi Cv   200
Cv = 400 GPM/2 = 200 4
U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

Application requires a modulating 2-way, 400 GPM Butterfly valve. A valve of 4"
minimum would be selected. The 4" valve at 12 ft/second would be able to
withstand a capacity of 470 GPM without damage to the liner. The Cv of the 4"
HD valve at 60° open is 230, making it the best choice for controlability.
All prices are in US Dollars (USD)

APPENDIX

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

22-11
General Information

MODELS OF VALVES/APPLICATIONS
ENERGY ZONE
FLOW MEDIUM EPIV QCV PIQCV CCV HTCCV BALL GLOBE BUTTERFLY
VALVE VALVES
Chilled / Hot Water / Glycol EV P2, P6 Z2Q Z2QP B2(B), B2...HT B2VS, G2, G3, F6, F7… Z2
B3(B), B2VSS G7(D), HD, L,
B6 B3...L G6C Series VIC, SHP
3-Way Mixing B3(B) G3, G7 F7, HD/L,
VIC, SHP
3-Way Diverting Z3Q B3(B) B3...L G3, G7D F7, HD/L, Z3
VIC, SHP
Low Pressure Steam B2...HT B2VS G2, G6C F6 ...SHP
(up to 15 inlet psi)
Medium Pressure Steam B2VS G2B up to F6 ...SHP
(15–50 inlet psi) (up to 35 (35 inlet
psi only) psi only)
B2VSS, G2S, G6C
B2VB, (35 psi
B6VB only),
G6CS
High Pressure Steam B2VB, G2S, G6CS
(50-100 inlet psi) B6VB

WATER QUALITY RECOMMENDED PARAMETERS


Chilled Water, Closed Loops, and Hot Water Systems up to 212°F (100°C)
8.0 < pH < 10.3
Conductivity < 3000 MMHS
Iron < 0.5 ppm
Copper < 0.5 ppm
Molybdenum
Chilled Systems ➡ 100 ppm < < 150 ppm

U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


(Mild Steel Corrosion Inhibitor)
Molybdenum
Hot Systems ➡ 200 ppm <
(Mild Steel Corrosion Inhibitor)
< 250 ppm

Nitrite 1000 ppm


400 ppm < <
(Mild Steel Corrosion Inhibitor)

All prices are in US Dollars (USD)


Azole
> 5 ppm free and available
(Yellow Metal Inhibitor)
APPENDIX

Total Aerobic Bacteria < 1000 cells/ml


Anaerobic Bacteria < 50 cells/ml
Ammonia < 2 ppm
Turbidity
< 20 FTU’s
(in systems not containing a dye)
Particles
< 200,000
(0.5 micron particles/ml with no particles above 20 microns)
Polymer < 10 ppm
Type I Ultra Pure
Water EXCEPTIONS for Belimo valve and fittings if either type of media is considered. An assessment should be made by qualified personnel to
assure compatibility and risk factors.
Deionized Water

Use water with low levels of chloride and sulfate, less than 25 ppm. Water hardness should be less than 50 ppm of hard water ions (Ca, Mg).
When water hardness is at unacceptable levels, a water softener expert should be consulted.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

22-12
ANSI/FCI Standards
ANSI/FCI 70-2-2006 Specification

CONTROL VALVE SEAT LEAKAGE CLASSIFICATIONS (IN ACCORDANCE WITH ANSI/FCI 70-2)
Leakage Class Maximum Leakage Testing Procedures Required for
Test Medium Test Pressure
Designation Allowable Establishing Rating
No test required provided user and
I - - -
supplier so agree
Pressure applied to valve inlet with
outlet open to atmosphere or connected
Air or water at 50°F to 125°F 45-60 psig or max. operating
II 0.5% of rated capacity to a low head loss measuring device
(10°C to 52°C) differential whichever is lower.
full normal closing thrust provided by
actuator
III 0.1% of rated capacity As above As above As above
IV 0.01% of rated capacity As above As above As above
Pressure applied to valve inlet after
filling entire body cavity and connected
Max service pressure drop
0.0005 ml per minute of water piping with water and stroking valve
Water at 50°F to 125°F across valve plug, not to
V per inch of seat diameter per plug closed. Use net specified max
(10°C to 52°C) exceed ANSI body rating (100
psi differential. actuator thrust, but no more, even if
psi pressure drop minimum).
available during test. Allow time for
leakage flow to stabilize.
Actuator should be adjusted to
operating differential pressure
50 psig or max rated amounts
Not to exceed in following table Air or nitrogen at 50°F to 125°F conditions specified with full normal
VI across valve plug shown
based on seat diameter. (10°C to 52°C) closing thrust applied to valve plug seat.
whichever is lower.
Allow time for leakage flow to stabilize
and use suitable measuring device.

CONTROL VALVE SEAT LEAKAGE CLASSIFICATIONS (FOR CLASS VI ONLY)


(IN ACCORDANCE WITH ANSI/FCI 70-2-2006)
NOMINAL SEAT DIAMETER LEAK RATE
Inches DN/Millimeters mL per minute Bubbles per minute
1 25 0.15 1
U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

1½ 40 0.3 2
2 50 0.45 3
2½ 65 0.6 4
3 80 0.9 6
All prices are in US Dollars (USD)

4 100 1.7 11
6 150 4 27

APPENDIX
8 200 6.75 45

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

22-13
Water Guidelines
Pressure/Temperature Charts

MAXIMUM TEMPERATURE AND PRESSURE RATINGS PRESSURE/TEMPERATURE CHART FOR ANSI CLASS 150/300
FOR GLOBE VALVE BODIES BUTTERFLY VALVES

ANSI 125 ANSI 250


Iron Body Bronze Body Threaded
Flanged Iron Flanged

SATURATED STEAM TEMPERATURE BODY PRESSURE-TEMPERATURE RATINGS (PSIG)


Pressure Temp Pressure Iron Body
Temp (°F) Bronze Body Iron Body 125
(PSIG) (°F) (PSIG) Temp (°F) Thread/250
Thread Flange
Flange
0 212 55 302.6
+20 to 100°F 400 175 400
2 218.5 60 307.3
150°F 400 175 400

U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


4 224.4 65 311.8
175°F 392 170 385
6 229.8 70 316.0
200°F 385 165 370
8 234.6 75 320.0
225°F 375 155 355

All prices are in US Dollars (USD)


10 239.0 80 323.9
250°F 365 150 340
15 249.7 85 327.6
275°F 350 145 325
20 258.8 90 331.1
APPENDIX

300°F 335 140 310


25 266.8 95 334.6
350°F 300 125 280
30 274.0 100 337.9
Table provided complements of Warren Controls.
35 280.6 105 341.1
40 286.7 110 344.1
45 292.4 115 347.1
50 297.7 120 350.0

Table provided complements of Warren Controls.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

22-14
U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.
All prices are in US Dollars (USD)

CONTACT NAME
Belimo Aircontrols (USA), Inc.
COMPANY 33 Turner Road 1049 Fortunato Loop
Danbury, CT 06810 Sparks, NV 89436
ADDRESS
Phone (203) 791-9915 Phone (775) 857-4243
Fax (203) 791-9919 Fax (775) 857-4255
TOLL FREE TOLL FREE
PHONE Phone (800) 543-9038 Phone (800) 987-9042
Fax (800) 228-8283 Fax (800) 987-8875
FAX (800) ACTUATE

800-543-9038 USA
PROJECT NAME

Project Specifications Valve Specifications Actuator Specifications NOTES

Cv
Ball
CCV

Size
QCV

(in.)
Pipe

(psi)
(psi)
ePIV

Flow
Drop
Zone

Globe

PIQCV

(GPM)
On-Off

24 VAC

System
System

Desired
Desired

Quantity
Tri-State

120 VAC

Butterfly

Two-way

Pressure
Pressure
Switches

Fail-Safe

Close-Off
Three-way
Modulating

Floating Pt.

Energy Valve

866-805-7089 CANADA
203-791-8396 LATIN AMERICA/CARIBBEAN
Valve Quotation Form

22-15
APPENDIX
Terms and Conditions of Sale and Warranty

I. General until the shipment is unpacked, Client must make a request for inspection
1.1. The following Terms and Conditions of Sale and Warranty (“Terms”) by the carrier’s agent and file with the carrier within 15 days after receipt of
apply to the sale of products described in this Product Guide and products product and notify Seller of the same.
sold by Seller as an original equipment manufacturer (“OEM”) which may
not be included in this Product Guide (“Product” or “Products”). As used VI. Delivery
herein, “Seller” or “Belimo” refers to Belimo Aircontrols (USA), Inc., or 6.1. Seller undertakes to make every attempt to adhere to its stated delivery
Belimo Aircontrols (CAN), Inc., or Belimo Automation AG, or Belimo Brasil parameters and to make a timely delivery of the Products but does not
– Comércio de Automação Ltda. as applicable, and “Client” refers to the guarantee any delivery specifications. Each contract entered into for the
individual or business entity that purchases the Products directly from purchase of Products is not cancelable nor is Seller liable for any direct or
Seller. These Terms shall apply unless the Seller and Client mutually agree indirect losses that may arise, for any reason whatsoever, due to Seller’s
to different terms and memorialize such agreement in writing signed by failure to meet any stated or assumed delivery schedules.
both Client and Seller or (ii) unless Seller changes these Terms and
publishes the Terms on its Website to be found at: www.belimo.us, in which VII. Inventory Overstock
case the most recent Terms published on the Website will prevail. In case 7.1. If Client has an overstock of Product inventory, such Products received
Seller’s delivery includes software and/or application software and by Client cannot be returned unless and until: (i) Client alerts Seller that it
accompanying documentation, the terms of the license agreement for such intends to return some overstock of Products, (ii) Seller agrees to accept
software and/or application software are applicable in addition to these such return, (iii) Client obtains a Return Material Authorization ("RMA")
Terms. However, in case of conflicts between the terms and conditions of number from Seller for such return of such Products, and (iv) Client follows
the license agreement and the Terms, the terms and conditions of the all return instructions provided by the Seller. The RMA number must be
license agreement shall prevail. clearly written on the outside of all packaging for any returned overstock of
Products.
II. Price 7.2. Only such Products returned in original packaging and shipped to
2.1. The Seller’s price for Products (the “Price”) is net, F.O.B. Point of Seller at Client's cost may be accepted for return under this Section. Client
Origin, and is calculated in US currency for sales made by Belimo is also responsible for payment of a restocking charge for all returned
Aircontrols (USA), Inc., and calculated in Canadian currency for sales made overstocked Products in an amount no less than 20% of the invoice value
by Belimo Aircontrols (CAN) Inc., and Brazilian currency for sales made by of the Products ("Restocking Charges"). Any piping package or custom
Belimo Automation AG or Belimo Brasil – Comércio de Automação Ltda. to order returns carry a minimum restocking charge of 75% of the invoice
Clients in Brazil. value. Returns that result from Seller errors and not overstocking will be
2.2. The Price, unless otherwise agreed upon, does not include freight and credited in full and will not be subject to Restocking Charges.
packaging (wooden crates, pallets, etc.), the costs of which will be charged 7.3. Any Product received damaged or showing evidence of having been
to Client at cost for each shipment and shall be payable with payment of the installed will be refused or assessed a higher restocking charge. Custom
Price. kits designed to a Client's unique specifications are not returnable.
2.3. Orders for Products where the total order has a net value of less than 7.4. If Client requests product to be returned to Client, the Client will be
US $300 (CAN $300) will be subject to a US $20 (CAN $20) handling fee responsible for return shipping charges. See specific product literature for
(the “Handling Fee”). The Handling Fee will not be charged for orders of exclusions or exceptions.
Products with a net value equal to or greater than US $300 (CAN $300) or 7.5. Any Products that are retrofit are not returnable.
for Products ordered through Seller’s e-commerce ordering system at:
www.belimo.com. VIII. Handling, Installation and Use of Products
2.4. Seller reserves the right to make partial deliveries of orders of 8.1. Products are only intended for installation and commissioning by
Products, each of which deliveries may be invoiced separately by Seller. trained technicians.
2.5. The Price does not include charges for wiring diagrams, installation, 8.2. The installation and exchange of Products may only be carried out by

U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


and commissioning, which will be charged to Client separately and will be trained technicians. Products may only be handled by trained technicians
payable on demand. and only in accordance with the most current valid data and installation
sheet.
III. Payment
3.1. Invoices are payable in US currency for sales made by Belimo IX. Limited Warranty
Aircontrols (USA), Inc., and in Canadian currency for sales made by Belimo A. 5-year Limited Warranty

All prices are in US Dollars (USD)


Aircontrols (CAN); Inc., and in Brazilian currency for sales made by Belimo 9.1. Products that are designated by Seller as carrying a 5-year warranty to
Automation AG on behalf of Brazil or Belimo Brasil – Comércio de a location in the United States, Canada, or Latin America shall carry a 5-year
Automação Ltda. Payments on invoices are due no later than 30 days from warranty. The 5-year warranty is unconditional for the first two years from
APPENDIX

the date of invoice, without any deductions. the date of sale of the Products to Client, subject to the Limitation On
3.2. If Client maintains an outstanding balance for 45 days or more after the Warranty in Section 9C. After the first two years from the date of sale, the
date of invoice, Client may be subject to restricted shipments of Products. warranty coverage shall not apply to damage to Products not resulting from
A Client may also be required to pay for all future deliveries of Products on normal wear and tear (e.g. negligence, misuse, or failure to maintain).
a cash-on-delivery or approved credit card only basis. Product specific terms of warranty with regard to warranty period or
conditions of warranty may apply to certain specified Products as stated in
IV. Title and Risk the documentation for those Products.
4.1. Title to Products will pass to Client from the Seller based upon the B. 2-year Conditional Warranty
agreed Incoterms as stated on the Order Confirmation. The Seller retains 9.2. Products that are designated by Seller as carrying a 2-year warranty to
the right to a return of the Product when payment is not received. a location in the United States, Canada, or Latin America shall carry a 2-year
warranty. The 2-year warranty is conditional from the date of sale of the
V. Damage or Loss in Transit Products to Client, and the warranty coverage shall not apply to damage to
5.1. Seller assumes no liability for damage or loss of shipment of Products, Products not resulting from normal wear and tear (e.g. negligence, misuse,
which risk shall at all times remain with the carrier. All shipments must be or failure to maintain). Product specific terms of warranty with regard to
unpacked and examined by Client immediately upon receipt. Any external warranty period or conditions of warranty may apply to certain specified
evidence of loss or damage must be noted on the freight bill accompanying Products as stated in the documentation for those Products.
the shipment of Products or carrier’s receipt and signed by the carrier’s C. Limitation On Warranty; Warranty Disclaimer
agent at the time of delivery. Failure to do so will result in the carrier’s 9.3. Seller’s warranties hereunder shall be null and void in the event of any:
refusal to honor any claim relating to damage of Products. Client must also (a) modification or unauthorized repairs of Products by Client; (b)
notify Seller within 5 days of such damage by providing Seller with a copy unauthorized incorporation or integration of Products into or with Client’s
of the freight bill or damage report so that Seller can file a claim for loss or equipment; (c) use of Products in an unauthorized manner; or (d) damage
damage in transit with the carrier. If the damage does not become apparent to Products not caused by Seller.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

22-16
Terms and Conditions of Sale and Warranty

9.4. These Terms constitute the entire understanding and agreement exchanged or replaced Products are shipped by Seller (the “Replacement
between Seller and Client regarding the warranties that cover Products and Warranty Period”).
supersedes all previous understandings, agreements, communications and 9.16. If Seller determines that Product under warranty is to be replaced,
representations. All Seller warranties are extended only to Client and are Seller may elect to send a replacement in advance of receiving the returned
non-transferrable. All Seller warranties shall extend only to HVAC use of the item. For valve products 2-1/2” in diameter or greater, a purchase order is
Products. If Products are used in non-HVAC applications (e.g., aircraft, required. An invoice will be issued and shall be due and payable if the
industrial processes, etc.), Seller’s warranties will not cover such Products. returned Products are not received by Seller within 60 days from the date
Client will be solely responsible for any damage to or malfunction of that the replacement Products are shipped. Additional charges may apply if
Products or for any damage resulting from such use of Products. the nature of the problem has been misrepresented by Client.
9.5. Both the conditional and unconditional warranties hereunder cover the 9.17. New Products ordered in an attempt to circumvent the warranty
Products only, and do NOT cover labor associated with the troubleshooting, process may NOT be reimbursed if, upon receipt of returned Products, it is
removal or replacement of such Products. determined that the defect in the returned Products is actually field related,
9.6. EXCEPT FOR THE EXPRESS WARRANTIES SPECIFIED IN SECTION IX, or the Products have been returned for cosmetic reasons only.
SELLER MAKES NO OTHER WARRANTIES, EITHER EXPRESS OR IMPLIED,
AND DISCLAIMS ALL OTHER WARRANTIES, INCLUDING BUT NOT LIMITED X. Liability Disclaimer
TO THE IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE 10.1. IN NO EVENT SHALL SELLER HAVE ANY LIABILITY TO CLIENT OR
AND IMPLIED WARRANTY OF MERCHANTABILITY. ANY THIRD PARTY FOR ANY (a) LOST PROFITS OR COSTS OF
D. Remedies PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES, OR FOR ANY
9.7. If a defect arises in the Product and an RMA is issued as provided in INDIRECT, INCIDENTAL, SPECIAL OR CONSEQUENTIAL DAMAGES, OR (b)
Section 9.8, Seller will, at its option and to the extent permitted by law, either ANY DAMAGES WHATSOEVER RESULTING FROM THE PERFORMANCE OR
(1) repair the Product at no charge, using new or refurbished replacement A TEMPORARY OR PERMANENT LOSS OF USE OF PRODUCTS, HOWEVER
parts or (2) replace the Product with a new Product. In the event of such a CAUSED UNDER ANY THEORY OF LIABILITY AND WHETHER BASED IN
defect, to the extent permitted by law, these are Client’s sole and exclusive CONTRACT, TORT (INCLUDING NEGLIGENCE), STATUTE OR OTHERWISE.
remedies. THE FOREGOING LIMITATIONS SHALL APPLY EVEN IF SELLER HAS BEEN
9.8. Client cannot return Products to Seller unless: (i) Client notifies Seller ADVISED OF THE POSSIBILITY OF SUCH DAMAGES AND NOTWITHSTANDING
that it intends to return such Products, (ii) Seller agrees to accept the return THE FAILURE OF ESSENTIAL PURPOSE OF ANY LIMITED REMEDY STATED
of such Products, (iii) Client obtains a RMA number from Seller for the HEREIN. SELLERS MAXIMUM AGGREGATE LIABILITY UNDER, ARISING
return of such Products, and (iv) Client follows all return instructions FROM OR IN CONNECTION WITH THE SALE OF ITS PRODUCTS TO CLIENT,
provided by the Seller. Client shall promptly notify Seller of Products’ alleged SHALL BE LIMITED TO THE AMOUNT PAID BY CLIENT FOR THE PRODUCT
defect and provide Seller with other evidence and documentation reasonably DEEMED RESPONSIBLE FOR THE LOSS OR DAMAGE.
requested by Seller. The RMA number must be clearly written on the outside 10.2. Client releases Seller in full from any possible third party claims
of all packaging for any returned Products. Only Products returned to the resulting in connection with the circumstances listed above. This also
proper location as instructed by Seller and identified with an RMA number applies to claims in connection with products liability.
will be considered for credit. 10.3. If Client becomes aware that any third party has made or appears likely
9.9. Seller will only accept for return Products returned in original to make any claim regarding Products (including, without limitation,
packaging. All returned Products must be shipped to Seller at Client’s cost. regarding Product defects or rights infringed by Products), then Client shall
Such returned Products must be received within one year from original sale immediately inform Seller and afford to Seller all assistance that Seller may
date to Client, in as-new condition, adequate for resale as new Products to require to enforce its rights and defend such claim.
qualify for credit. Client will be responsible for payment of a restocking
charge for all returned Products in an amount no less than 20% of the XI. Proper Law and Jurisdiction
invoice value of the Products (“Restocking Charges”). Product received 11.1. All sales of Products under these Terms described herein shall be
damaged or showing evidence of having been installed will be refused or governed by the laws of the State of Connecticut, without regard to its
U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

assessed a higher restocking charge. Custom kits designed to a Client’s conflicts of law principles, and Seller and Client agree to submit to the
unique specifications are not returnable. If Client requests repaired Product exclusive jurisdiction of the federal and state courts located in the State of
to be returned to them, Client will be responsible for return shipping Connecticut with respect to any dispute arising from the subject matter
charges. See specific Product literature for exclusions or exceptions. hereof. The Seller and Client hereby waive all rights to a jury trial in
9.10. Returns that result from Seller’s breach of these Terms will be credited connection with any claims relating to the subject matter hereof. All causes
All prices are in US Dollars (USD)

in full and will not be subject to Restocking Charges. of action arising out of or connected to the sales of Products under these
9.11. Seller-authorized support technicians are available for troubleshooting Terms shall be resolved individually, with no right by Seller or Client to
before any shipments to Seller. The contact information for Belimo customer participate in a representative capacity, or as a member of any class action.

APPENDIX
service is listed on the back page of Belimo’s Product Guide and Price List
(“PGPL”) or may be found at www.belimo.com. XII. Privacy and Data
9.12. If Seller determines that a problem cannot be resolved without Product 12.1 Seller places great value on the implementation of lawful data
replacement, an RMA number will be issued by Seller for return of the processing to protect Client’s personal data. Seller is obliged to process
Products. Prior to returning any Products under a warranty, Client must Client’s personal data in accordance with applicable law. Seller is dependent
obtain an RMA number from Seller, along with shipping instructions for the on the services of a third party for the provision of its services. Seller has
return. The RMA number must be clearly written on the outside of the box obligated the third party to process Client’s data only in connection with the
containing the returned Products. Only Products returned to the proper services agreed with Seller, to ensure the same level of data protection as
location and identified with an RMA number will be accepted by the Seller. Seller, and to not pass on Client’s data to other third parties without Client’s
9.13. All returned Products should be packaged appropriately to prevent consent. When processing Client’s data and transferring Client’s data to third
further damage. Seller reserves the right to refuse any returned Product if parties, Seller will use reasonable commercial efforts to provide an
improperly packaged or labeled (e.g. without an RMA number on the outside appropriate level of data protection and that appropriate organizational and
of packaging). Products returned without proper RMA documentation will technical measures are implemented to protect Client’s personal data. More
void Seller’s warranty. Seller is not responsible for charges that Client may detailed information on Seller’s data protection guidelines is available from
incur as a result of the removal or replacement of Products. the following Internet address: www.belimo.com/privacy.
9.14. Repaired or replacement Products are shipped from Seller via ground
shipment. Other shipping methods are available at the sole expense of the XIII. California Proposition 65
Client. 13.1 WARNING: Some Belimo Products can expose you to chemicals which
9.15. Repaired, replaced or exchanged Products will carry a warranty for a are known to the State of California to cause cancer, birth defects, or other
period of time equal to the greater of: (i) the remainder of the original 5-year reproductive harm. Please refer to the Product specific Technical Data sheet
warranty or 2-year warranty that was applicable to the repaired, replaced or at www.belimo.us for details.
exchanged Products, or (ii) six months, effective from the date the repaired, For more information see www.p65warnings.ca.gov

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

22-17
Actuator/Valve Specification

Section 230900 – INSTRUMENTATION AND CONTROL FOR HVAC 2.16 CONTROL VALVES

PART 1 – GENERAL A. Manufacturer:


1. Manufactured, brand labeled or distributed by BELIMO.
The following addition should be made to 1.2.B.
B. Control Valve Actuators:
1.2 SUMMARY 1. Size for valve close off at 100 percent of total system (head)
pressure for two-way valves and three-way diverting valves; and
B. Related Sections include the following: 100 percent of total system (pump) head differential pressure for
3. Division 23 Section “Hydronic Piping” for requirements for piping three-way mixing valves. [Combination of actuator and trim
packages for control valves. shall provide minimum close-off pressure rating of [100 psid]
[200 psid] <Insert Close-Off Rating>.]
Choose optional close-off pressure rating statement for higher (greater
The following replaces the noted specification sections, except as noted.
than 100psid) requirements.
2. Coupling: directly couple and mount to valve stem, shaft ISO-style
2.15 ACTUATORS direct-coupled mounting pad.

Consultants and Specifiers


3. Shall meet all the requirements of 2.15.A. Electronic Actuators.
A. Electronic Actuators:
Specifier must include section 2.15.A Electronic Actuators when using
1. Manufactured, brand labeled or distributed by BELIMO.
this section.
2. Size for torque required for damper seal at load conditions.

Get the Latest Actuator and


3. Coupling: V-bolt dual nut clamp with a V-shaped, toothed cradle.
4. Mounting: Actuators shall be capable of being mechanically and
electrically paralleled to increase torque if required.
C. Control Valves:
1. Factory fabricated of type, body material, and pressure class

Valve Specifications
based on maximum pressure and temperature rating of piping
5. Overload protected electronically throughout rotation. system, unless otherwise indicated.
6. Fail-Safe Operation: Mechanical, spring-return mechanism. 2. Sizing:
[Electronic fail safe shall incorporate a visual indication of the
a. Two-Position: Line size or size using a pressure differential of
fail safe status on the face of the actuator. The power fail
Visit www.Belimo.us
1 psi.
position shall be field adjustable between 0 to 100% in 10°
increments. The electronic fail safe shall have a 2 sec [0-10 0-10 b. Two-Way Modulating: [3 psid] 5 psid or twice the load pressure
3 psid

or Call Your Local Representative


sec] <Insert Timing between 0-10 sec>] operational delay.]
sec drop, whichever is more.
Choose electronic fail safe option when specifying pressure c. Three-Way Modulating: Twice the load pressure drop, but not
independent valves (2-1/2” through 6”). more than [3 psid] 5 psid.
3 psid
7. Power Requirements: 24 [120] 120 [230]
230 V ac, maximum 10 VA [22 [2. Sizing (steam):
VA] at 24-V ac or 8 W at 24-V dc. a. Two-Position: Line size or sized using 10% of inlet
Choose 22 VA is selecting electronic fail safe option in 2.15.A.6. gauge pressure.
(above). b. Modulating: 15 PSIG or less inlet steam pressure, the
8. Modulating Actuators shall be fully programmable through an pressure drop shall be 80% of inlet gauge pressure.
EEPROM without the use of actuator mounted switches Higher than 15 PSIG inlet steam pressure the pressure
drop shall be 42% of the inlet absolute pressure.]
9. Temperature Rating: -22 to +122ºF -30 to +50ºC [-58 to +122ºF
+50ºC]
-50 to +50ºC Choose this option when specifying steam valves.
10. Housing: Minimum requirement NEMA type 2 (4/4X) 4/4X / IP54 (IP67)
IP67 3. The control valve assembly shall be provided and delivered from a
single manufacturer as a complete assembly.

U16000 - 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


mounted in any orientation. .
11. Agency Listings: ISO 9001, cULus, CE or CSA
12. The manufacturer shall warrant all components for a period of 5 D. The manufacturer shall warrant all components for a period of 5
years from the date of production, with the first two years years from the date of production, with the first two years
unconditional. unconditional (except as noted).

All prices are in US Dollars (USD)


B. Industrial Actuators (ONLY TO BE USED WITH 2.16.I Butterfly Valves E. Pressure Independent Control Valves
– Resilient Seat and 2.16.J Butterfly Valves – High Performance.)
1. Manufactured, brand labeled or distributed by BELIMO. 1. NPS 2 and Smaller: Forged brass body rated at no less than 400
APPENDIX

2. The combination of valve and actuator shall meet the close-off PSI, chrome plated brass ball and stem, female NPT union ends,
requirements as specified in Section 2.16.H – Butterfly Valves. dual EPDM lubricated O-rings and a brass or TEFZEL
3. Coupling: ISO 5211 mounting standards. characterizing disc.
4. Overload Protection: A self resetting thermal switch embedded in 2. NPS 2-1/2 through 6: GG25 cast iron body according to ANSI
the motor. Class 125, standard class B, stainless steel ball and blowout proof
5. Manual Override: Actuator shall be equipped with a hand wheel or stem, flange to match ANSI 125 with a dual EPDM O-ring packing
shaft for manual override to permit operation of the actuator in the design, PTFE seats, and a stainless steel flow characterizing disc.
event of an electrical power failure 3. Accuracy: The control valves shall accurately control the flow from
6. Power Requirements: 24VAC [120VAC] [230VAC] 1 pH. 0 to 100% full rated flow with an operating pressure differential
range of 5 to 50 PSI differential across the valve with a valve body
7. Auxiliary Switches: 2 SPDT rated 3A at 250 VAC. accuracy of +/- 5% variance due to differential pressure fluctuation
8. Temperature Rating: -22 to +150ºF. -30 to +65ºC. or +/- 10% total assembly error incorporating differential pressure
9. Housing: Minimum requirement NEMA type 4X/ IP67 with an fluctuation, .manufacturing tolerances and valve hysteresis
industrial quality coating. Actuator shall have an internal heater to 4. Flow Characteristics: Equal percentage characteristics.
prevent condensation within the housing. A visual indication Remember to modify 2.15.A.6 to incorporate electronic fail-safe option
beacon shall indicate position status of the device. for 2-1/2” through 6” Pressure Independent Valves, where fail safe
10. Agency Listing: ISO, CE, CSA applications are required.
11. The manufacturer shall warrant for 2 years from the date of
production.

800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA/CARIBBEAN

22-18
Belimo Americas Platinum Distributors

ACR Supply Company Inc. Control Stop RSD / Refrigeration Supplies Distributor
USA

4040 S. Alston Avenue 1000 N Pine Street, Suite 6 26021 Atlantic Ocean Drive
Durham, NC 27713 Spartanburg, SC 29303 Lake Forest, CA 92630
Phone: 919-765-8081 Phone: (864) 586-3818 Phone: 949-380-7878
With branches in NC With a branch in NC With branches in CA, NV, OR, AK, AZ,
ID, UT, WA, MT
Aireco Supply Engineered Control Systems
9120 Washington Boulevard 5627 NW 74th Avenue Saint Louis Boiler Supply, Co.
Savage, MD 20763-0414 Miami, FL 33166 617 Hanley Industrial Court
Phone: 301-953-8800 Phone: 305-885-8804 St. Louis, MO 63144
With branches in MD, VA With branches in FL Phone: 314-962-9242
Amcon Controls, Inc. G & O Thermal Supply South Side Control Supply, Co.
11906 Warfield Street 5435 N. Northwest Highway 488 N. Milwaukee Avenue
San Antonio,TX 78216 Chicago, IL 60630 Chicago, IL 60610-3923
Phone: 210-349-6161 Phone: 773-763-1300 Phone: 312-226-4900
With branches in Houston, TX With branches in IL, IN and WI With branches in IL, IN
and Mandeville, LA
Industrial Controls Distributors, LLC Stromquist and Company
Relevant Solutions (formally Climatic Control) 4620 Atlanta Road
(formally Applied Automation) 1245 W. Canal Street Smyrna, GA 30080
3186 South Washington Street, #230 Milwaukee, WI 53233 Phone: 404-794-3440
Salt Lake City, UT 84115 Phone: 414-259-9070 With a branch in Orlando, FL
Phone: 801-486-6454 With branches in WI Temperature Control Systems
With branches in CA, CO, TX
Industrial Controls Distributors, LLC 10315 Brockwood Road
Boston Aircontrols, Inc. 17 Christopher Way Dallas, TX 75238
8 Blanchard Road Eatontown, NJ 07724 Phone: 214-343-1444
Burlington, MA 01803 Phone: 800-543-8200 With branches in OK, TX
Phone: 781-272-5800 With branches in GA, KY, IN, MA, ME, T.F. Campbell Company
NC, NY, OH, PA, TN
Charles D. Jones Co. 1203 Edgebrook Avenue
445 Bryant Street, Unit #1 Interstate HVAC Controls Pittsburgh, PA 15226
Denver, CO 80204-4800 30 Vineland Street Phone: 412-881-8006
Phone: 800-777-0910 Brighton, MA 02135 Tower Equipment Co., Inc.
With branches in CO, MO, KS Phone: 617-782-9000 1320 West Broad Street
Cochrane Supply and Engineering, Inc. Jackson Controls Stratford, CT 06615
30303 Stephenson Highway 1708 E. 10th Street Phone: 800-346-4647
Madison Heights, MI 48071-1633 Indianapolis, IN 46201 Twinco Supply Corporation
Phone: 800-482-4894 Phone: 317-231-2200
U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.

55 Craven Street
With branches in MI, OH and KY
M & M Controls Huntington Station, NY 11746-2143
Columbus Temperature Control 9E West Aylesbury Road Phone: 800-794-3188
1053 E. 5th Avenue Timonium, MD 21093 With branches in NY
Columbus, OH 43201 Phone: 410-252-1221
Phone: 800-837-1837
All prices are in US Dollars (USD)

With branches in VA
Canada

For a complete list of distributors


Controlco Meier Supply in Canada, please visit our
3451 Vincent Road 275 Broome Corporate Pwky website: www.belimo.ca
Pleasant Hill, CA 94523 Conklin, NY 13748 or call toll free: 866-805-7089
Phone: 916-927-5599 Phone: 607-797-7700
With branches in CA, NV, TN With branches in NY, PA
Brazil

Control Depot Minvalco, Inc. For a complete list of distributors


9304 G Court 3340 Gorham Avenue in Brazil, please visit our
Omaha, NE 68127 Minneapolis, MN 55426-4267 website: www.belimo.com.br
Phone: 866-809-7408 Phone: 952-920-0131 or call: 55 11 3643-5656
With a branch in Lincoln, NE With branches in MN
Control Products Relevant Solutions
Latin America &

For a complete list of distributors


9101 Jameel, Suite 130 9750 West Sam Houston Pwky North in Latin America and the Caribbean,
the Caribbean

Houston, TX 77447 Suite 190 please visit our website: www.belimo.us


Phone: 713-849-7200 Houston, TX 77064 or call: 203-791-8396
With a branch in San Antonio, TX Phone: 281-295-8850
From Design to Delivery, Always with One Intention,
Complete Customer Satisfaction

Advanced Butterfly Valves 6-way ePIV


University of Oregon’s Football Complex, Oregon Innes Air, Mexico City

U16000- 04/19 - Subject to change. © Belimo Aircontrols (USA), Inc.


Sensors Belimo Energy Valve™ PIQCV
250 South Street, New York Red Wing School District, Minnesota Wentworth Institute of
Technology, Massachusetts

All prices are in US Dollars (USD)


Belimo worldwide: www.belimo.com

BELIMO Americas
USA Locations
33 Turner Road, Danbury, CT 06810
1049 Fortunato Loop, Sparks, NV 89436
Tel. 800-543-9038, Fax 800-228-8283, customerservice@us.belimo.com

Canada Location
5845 Kennedy Road, Mississauga, Ontario L4Z 2G3
Tel. 866-805-7089, Fax 905-712-3124, orders.ca@ca.belimo.com

BELIMO Brasil Comércio de Automação Ltda.


Rua Barbalha, 251, São Paulo/SP, Brazil
Tel: 55 11 3643-5656, Fax: 55 11 3643 5657, atendimentoaocliente@br.belimo.com

BELIMO Mexico
Av. Insurgentes Sur 1602, Col. Credito Constructor, Del. Benito Juarez, Mexico City 03940
Tel: 55 4125 7890, servicioalcliente@mx.belimo.com

Latin America and the Caribbean Customer Service


Tel. 203-791-8396, Fax 203-791-9139, servicioalcliente@us.belimo.com

You might also like