RACKMOUNTED ONLINE UPS - STANDARD / LONG BACK UP TYPE

Providing customer satisfaction is our key to our business.


Product Name: RC1K/RC1KS to RC3K/RC3KS
Key Features
◆Rack Mounted High Frequency Double Conversion Online UPS
◆Single Phase,0.9/0.8PF
◆Fully digitized microprocessor control
◆Wide input voltage range
◆Advanced PFC technology
◆Self-testing when UPS startup
◆Advanced battery management
◆Automatic battery charging in UPS off mode
◆Lightning and surge protection
◆Short circuit and overload protection
◆Smart RS232 communication with monitoring software
◆Battery voltage and load capacity display
◆LCD Disply ,SNMP card , USB Communication is (Optional)

TECHNICAL SPECIFICATION
Item Model RC1K RC1KS RC2K RC2KS RC3K RC3KS
Capacity VA / Watts 1KVA/0.9KW 1KVA / 0.8KW 2KVA/1.8KW 2KVA / 1.6KW 3KVA/2.7KW 3KVA / 2.4KW
Normal voltage 220VAC/ 110VAC
a) (110±5 ~ 300±5) VAC when Load at 0-60%
b) (120±5 ~ 300±5) VAC when Load at 60-70%
220V Voltage range
Input C) (140±5 ~ 300±5) VAC when Load at 70-80%,
D) (160±5 ~ 300±5) VAC when Load at 80-100%
Power Factor 0.97
Frequency range Normal 50HZ/60HZ±4, 40~60Hz(set by winpower)
Voltage range 220/110VAC+-2%
Frequency range 50Hz/60Hz+-0.2 (Battery mode)
Wave form Pure Sine Wave
0 ms (AC mode and battery mode)
Transfer time
Transfer time: 4ms (typical 2.5ms),AC mode and bypass mode
Output Distortion (Full Load) linear
≤3% ≤3% ≤4% ≤4% ≤4% ≤4%
load
Degree of distortion (Full
≤6% ≤6% ≤7% ≤7% ≤7% ≤7%
Load) nonlinear load
Overload capacity >108% 30s turn to bypass mode; >150%, 300ms turn to bypass
Load peak ratio 3:1(max)
Type Maintenance free valve regulated lead acid (VRLA) battery
Backup time >3Mins >5Mins >3Mins
Battery DEPENDS ON DEPENDS ON DEPENDS ON
BATTERY 90%capacity BATTERY 90%capacity BATTERY
90%capacity after
Recharge time CAPACITTY (AH) after 5 hrs CAPACITTY (AH) after 5 hrs CAPACITTY (AH)
5 hrs charging
charging charging
Bypass Automatic while overload or ups fail.
Display LED Load level / Battery level / Battery mode / Line mode / Inverter , Bypass ,Over load , Fault
LCD Option BAT % VDC, Input VAC HZ, Output VAC HZ , Load %
Battery Mode Beeping every 4 seconds (re-settable) and every second when battery low
Audible Alarm Overload Beeping twice every second
Fault Beeping Continuously
Communications RS-232 Interface,With monitoring software,USB Option,SNMP NetAgent Option
Surge protection RJ-45 I/O port available for network or Fax/Modem
Working temperature - 20℃〜40℃
Environment
Humidity 0-95% non-condensing
UPS Product size WxDxH (mm) 483 x 450 x 88 (2U)
UPS CTN size WxDxH (mm) 605*610*270
UPS CTN weight KG/PCS 20/1PCS 15/1PCS 18/1PCS 18.2/1PCS 19/1PCS 19.2/1PCS
BP Product size WxDxH (mm) 483 x 450 x 88 (2U)
BP CTN size WxDxH (mm) 605*610*270
BP CTN weight KG/PCS included in ups N/A 305/1PCS N/A 35/1PCS N/A
Note: All specifications are subject to change without prior notice

Manufactured and Distributed by: