CONSTRUCTION & SPECIFICATIONS

Inner tube: PVC


Weaving Jacket: Polyester staple as warp and polyester filaments/PP as weft, plain or twill
Inner Dia.: 1-1/2, 2-1/2
Working Pressure:, 8bar
Length: 20 ~35m ready stock
Application: fire-fighting, Construction, Industrial. Shipyard and Agriculture

CONTACT: 08999377799

Product Description
When the fire happens in the fire compartment, alarm controller can drive this audio and video alarm video alarm, in
order to tell the person on site to escape fast. We have three kinds of Sounder Strobe . Addressable Sounder Strobe
. Conventional Sounder . Flashing Lamp
Product Description
Type: Smoke detectors(ISD) ExteriorSize: diameter:108X40mm FixSize: 78mm Weight: 119g Technical
specifications and explanation: In many families, the country forces to stipulate must have to install smoke detector,
the goal is for prevent the fire the occurrence, this product the early time which occurs at the fire once has the smog
to occur may induce to the smog, at the same time made 85 decibels sounds and sends out the light to report to the
police informs the user to have the fire, should promptly take the measure, this product also had the networking
function, might at the same time connect 39 products, suited the family to have many rooms the user, after the joint, a
room had the fire, other rooms alarm apparatus also at the same time started report to the police, prompt the user.
This product outward appearance is attractive, the function may expand; 1. Operating Voltage: The 9V level folds the
battery 2. Static current: <=10mA 3. Audio current: <=10mA 4. Shines the diode under the inspecting mode to govern
and restrain for 40 seconds to glitter a time, in reports to the police under the condition to shine two aurora fast to
glitter. 5. The buzzer does not make the sound under the inspecting mode, owes presses the buzzer when the battery
to make the short prompt sound, in reports to the police under the condition the buzzer to send out continues to
report to the police the sound. 6. Environment: Temp. Range: -10 º C ~50 º C humidity Range: <95% (40 º C, does
not have congeals). 7. Suitable place A. Guesthouse, hotel, apartment, eating house, hotel and so on; B. Assembly
hall, memorial hall, ancient temple and so on; C. Museum, library, art museum and so on; D. Department store,
market, warehouse, bank and so on. 8. Installs requests: The position of installation have to satisfy requests: A.
When the installment is smaller than highly 6 meters, like the detector in separates on Liang, then does not have to
surpass 0.3 meter the detector undersurface to the ceiling distance; B. Has the air conditioned room detector to leave
delivers the gusty area at least 1.5 meters; C. The detector installs the angle not to be able to be bigger than 45; D.
The detector installs in is away from wall or the wall Liang 0.6 meter above place. 9. Detectors tests: Press down
detector test button which have installed the battery, and maintains above 2 seconds, the detector reports to the
police, the light emitter diode fast glitters, the buzzer sends out continues to report to the police the sound; The pine
opens tests the button, the detector restores to the inspecting mode. 10. Notes: A. When installs the battery pays
attention to the battery polarity, installs counter- can cause the detector damage. B. Environment dust is big, can
pollute the detector.
‧LED test NW8200-4 Conventional Fire Alarm Control Panel

Product detailed introduction :

Key Specifications:

‧Model No: NW8200-4 ( 4 ZONE )


‧Input voltage: 240VAC (50Hz/60Hz) +/-10%
‧Battery: 2X12V/2.3AH
‧Charging voltage protection: 1.0A glass fuse
‧Sounder output: 24V nominal EOL 10K resistor
‧Auxiliary contacts: 30VDC, 1A max. NC/NO
‧Main supply protection: glass fuse
‧Sounder protection: 2 x 500mA glass fuse
‧Reverse battery protection: charger glass fuse
‧Zone EOL: 5.6K resistor
‧Color: IVORY
‧Zoned visual red alarm and yellow trouble indicators
‧Continuous signal during alarm
‧Built-in battery charger
‧Low / no power and battery detection
‧Automatic loading and testing of battery
‧Battery over-discharge protection
‧Evacuate (alarm resound)

NW8200L-8/16 Conventional Fire Alarm Control Panel


NW8200L-8/16 Conventional Fire Alarm Control Panel

Product detailed introduction :

8/16 zone conventional fire alarm panels


Both End of Line Resister and Active End of Line can be used
Day/night mode selected
Zone isolate control
One man test
Key-control evacuate over-ride
Fire alarm output for remote alarm
Class change terminal for remote control
Active EOL enables multiple alarm reporting from same zone
Active EOL max 15 fire detectors and infinite manual buttons each zone
Resistor EOL up to 25 detectors and infinite manual buttons each zone

Technical Specifications
Power supply: 230VAC 50/60Hz
Operating Environment:

Temperature: 0 ~ +40°C
Relative Humidity: 95%
Dimension 321mm x 247mm x 88mm

Product

/w EPDw ULLTE2M

NW2102P-RT1 Conventional Heat Detector(Normal Type, DC24V, 2Wire)

Product detailed introduction :

‧ Model: NW2102P-RT1 (HEAT DETECTOR)


‧ Voltage: DC- 9V~40V (DC-24V, 2WIRE)
‧ Alarm Current:10mA~70mA
‧ Standby current: 60uA average, 55uA peak at 24VDC
‧ Standby current: 40uA average, 30uA peak at 12VDC
‧ Environmental temperature: 32 to 140 degrees Fahrenheit
‧ Humidity: 0 to 95% RH
‧ Detector sensitivity: nominal set at 10%/50cm
‧ Standard : EN54-7 UL268

‧ Type: Normal Type(DC-24V)

Portable fire monitor

Technical parameter

Model PSY30 PSY 40 PSY 50 PSY 60

Flow type Straight stream or fog pattern

Rated flow rate 2100L/min 2400L/min 3000L/min 3600L/min


Working
0.8MPa
pressure

Max pressure 1.2MPa

Throw distance ≥50m ≥60m ≥62m ≥65m

Pitch angle +30°~ +90°

Fog angle ≥120°

Material Fine aluminum alloy

Coupling type All type coupling are available

Weight ≤17kgs

MODEL PSY30ZB
Free swing fire monitor is one type of monitor
which takes advantage of water pressure to cause
the oscillation.It acquires the features of light
weight,small body and operates conveniently.In
fire field,the fire fighter can adjust the
monitor's pitch angle,swing frequency to get the
Description straight stream flow or fog pattern and extinguish
the specific area fire or target.It also can
extinguish fire,cooling the temperature of fire
field and protect fire fighter's life safety.Free
swing fire monitor has saved efforts of fire
fighter to manually operate it.This monitor is the
best choice for special fire brigade.

Working pressure:0.8MPa(8 Bar)


Rated flow rate:2100Litre/min(567GPM)
Water throw distance≥55m

Main Max fog angle≥120°


technical Pitch angle:20-70°
parameters
Foam throw distance≥45m
Foam vertical throw distance≥30m
Swing frequency(times/min)≥4
Weight≤15kg