Data - Sheet-Sanwa Multi Meters

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 11

GENERAL CATALOG 2016

75
http://www.sanwa-meter.co.jp

Anniversary

GENERAL CATALOG
Dempa Bldg., 4-4 Sotokanda 2-Chome, Chiyoda-ku, Tokyo, 101-0021 Japan
Tel: +81-3-3251-0941 Fax: +81-3-3256-9740
2016
2016-1
75 Anniversary

Proudly celebrating our 75th anniversary.

In celebration of our anniversary, we would like to take this opportunity to


thank our loyal partners, distributors and customers. Sanwa has developed
countless measuring instruments since its founding in 1941, and Sanwa will keep
its mission to deliver unique measuring instruments to its valued customers.

since 1941
Clamp Meter
Tester
Insulation Resistance
Clamp Meter Insulation Resistance PC Link System, Analog Multitester Various Instruments
Tester Digital Multimeter

Exposition of clamp Exposition of Insulation Exposition of PC Link Exposition of analog Lux Meters.....P35

Top class quality meter.....P05


Clamp Meter
resistance Tester.....P13
Insulation Resistance Tester
system.....P19
Exposition of digital
multitester.....P29
Analog Multitester
Exposition of Lux meter.....P35
LX2.....P35

popular in 74 countries comparative chart.....P52∼P53


CAM600S.....P06
comparative chart.....P54
DM1008S.....P16
multimeter.....P20
Digital Multimeter
comparative chart.....P58∼P59
AP33.....P33
LX3132.....P35

Optical/Laser Power
around the world. DCL1000.....P06 DM508S.....P16 comparative chart.....P55∼P57 AU-31.....P31

Digital Multimeter
PC Link System,
Meter.....P36
DCL11R.....P07 HG561H.....P14 CD732.....P25 AU-32.....P31
Exposition of optical/
DCL1200R.....P08 M53.....P15 CD770.....P24 CP-7D.....P33
Laser power meter.....P36
DCL3000R.....P08 MG500.....P14 CD771.....P24 CX506a.....P30
LP1.....P37
Measurements become valid only when people place DCL31DR.....P09 MG1000.....P14 CD772.....P24 EM7000.....P30
OPM35S.....P37
DCM60R.....P08 PDM1529S.....P15 CD800a.....P25 SH-88TR.....P31
confidence in the quality of measuring instruments. Sanwa has OPM-360....P36
DCM400.....P06 PDM508S.....P16 KP1.....P27 SP-18D.....P32
OPM37LAN.....P36
supported the work of professionals for over half a century, DCM400AD.....P07 PDM5219S.....P15 PC20.....P23 SP20.....P32
DCM600DR.....P09 PC700.....P22 SP21.....P32 Thermo Meter.....P37
and has produced a myriad of different solutions through the
DCM660R.....P08 MΩ Tester.....P17 PC710.....P22 TA55.....P32 Exposition of Thermo
utilization of high levels of quality. DCM2000DR.....P09 DG34a.....P17 PC773.....P23 VS-100.....P33 meter.....P37

Analog Multitester
DCM-22AD.....P07 DG35a.....P17 PC7000.....P21 YX360TRF.....P31 TH1.....P38
DLC460F.....P09 DG36a.....P17 PC720M.....P21 YX-361TR.....P30 TH10.....P38
This quality control includes not only “products”, but also each PC Link 7.....P19 TH20.....P38
Exposition of clamp PM3.....P26 TH21.....P38
and every operation, maintenance services, and sales and
sensor.....P10 PM33a.....P27 TH3.....P37
marketing activities, and is thoroughly implemented utilizing CL-22AD.....P11 PM7a.....P26
Tachometer / Speed
CL3000.....P11 PM11.....P26
reliable systems and the intangible awareness of each of our Meter.....P39
CL33DC.....P11 PS8a.....P26
SE300.....P39
employees. is a Japanese name brand that lives up RD700.....P25
SE-9000.....P39
RD701.....P25
to the trust of engineers around the world through the SE-9000M.....P39

Various Instruments
provision of high quality measuring instruments. Earth Tester.....P40
Exposition of Earth
tester.....P40
PDR302.....P40

LCR Meter.....P40
LCR700.....P40

Detector.....P41
3 phase detector KS1.....P41
Sanwa’s mission 3 phase detector KS3.....P41

Accessories
(Moter Rotation Tester)
Voltage detector KD2.....P41
Sanwa sees its mission as contributing to global environmental
Assembly Training Kit.....P42
conservation and energy management through continuous advances
KIT-8D.....P42
in electrical and on-site measuring instruments, while “putting the PC20TK.....P42

trust and satisfaction of customers first”.


Calibrator.....P43
STD5000M.....P43

02 www.sanwa-meter.co.jp 03
PC Link System

Clamp Meter
Enhanced operational efficiency by means of data retrieval software, PC Link 7,
which can handle measurements for up to a maximum of 8 channels.
The PC Link system is the software dedicated to a PC for retrieving data outputted from a SANWA digital multimeter (PC series). The
operation screen displays graphs in real time to allow you to check changes in measured values (voltage, current, etc.) with ease.
Measured data can be saved on a CSV file, so it is easily processed on Excel. The ease of use in a variety of applications from data
retrieval, processing and analysis results in its extensive acceptance for business, education and personal use.

PC Link 7

Tester
Insulation Resistance
PC7000, PC720M, PC710
Max 8 Channels Applicable Model
PC700, PC773, PC20, PC20TK

■Data acquisition screen ■Alert indication

Highly visible alert


Send alert information by e-mails
Save them into files

Digital Multimeter
PC Link System,
Digital Multimeter
PC Link System,

■Multi-window flexible screen layout ■Traditional overlapped graphs and separated graphs by each channel.
 (Flexible size and position of each window)  Also, easily switchable display/hide.

Analog Multitester
Separated graphs Overlapped graphs

Customizable screen

Major features :
・Automatically detects a port connected with a digital multimeter ・Allows data saving into CSV files and sending e-mails of alert
・No additional driver installation required with Windows standard

Various Instruments
information with alarm setting.
USB drivers ・Allows data saving into CSV files with the date and time
・The retrieval interval can be set by seconds. The shortest appended.
reading interval of 0.2 – 0.3 seconds depending on the digital ・Multi-window, separated graphs by each channel
multimeter measuring function. ・Allows automatic e-mail of measurement data.
・Allows setting for vertical/horizontal zoom, reading at the ・Allows limited operations depending on the user with usage
cursor position, and Y axis split while retrieving data. restriction function.
・Allows automatic retrieval by schedule setting. ・Allows conditional recording by event function.

PC Link 7 operating environment


OS:Windows XP (32bit ) / 7 (32bit / 64bit) / 8 (32bit / 64bit) / 10 (64bit) CPU:Pentium Ⅳ 1.6GHz or better Memory:1GB or better Resolution:800×600 or above

Accessories
Optional accessories for PC Link products

KB-USB773 KB-USB7 KB-USB20


Optical link USB Optical link USB Optical link USB

For PC773 For PC7 series For PC20, PC20TK

●Microsoft and Windows are registered trademarks or brands of US Microsoft Corporation in the USA and other countries.

18 www.sanwa-meter.co.jp 19
Digital Multimeters
Clamp Meter

Clamp Meter
High accuracy & high resolution (PC Link)

PC7000
What is Digital Multimeter? Advantages of digital multimeters (DMMs)

1.
500000 Count for DCV, Dual Display
A digital multimeter is a convenient measuring instrument that Highly accurate measurement. Higher ■4-4 / 5digits 50000 count Optional
allows by itself the measurement of DC voltage, AC voltage, DC accuracy (1% or less) compared with an  (Selectable 5-4 / 5 digits 500000 count for DCV)
current, AC current and resistance (Pocket type DMM normally analog multimeter (approximately 3%) . ■Dual Display shows voltage/current and its
cannot be used for the measurement of current for safety reasons).  frequency, and AC components and DC
PC7000 Measuring range Best accuracy Resolution Input
 components of voltage/current
In addition to these basic measuring functions, most models are
impedance

2.
■AC True RMS DCV 500m/5/50/500/1000V ± (0.03%+2) 0.01mV
10MΩ
provided with features such as a diode test function and Reduced measuring loss due to high internal ■Low-pass filter for variable frequency drive(VFD) ACV 500m/5/50/500/1000V ± (0.5%+40) 0.01mV

continuity buzzer. Some of recent products feature the


DCA 500μ/5000μ/50m/500m/5/10A ± (0.1%+20) 0.01μA
impedance (low voltage drop between  circuit
Tester
Insulation Resistance

Tester
Insulation Resistance
ACA 500μ/5000μ/50m/500m/5/10A ± (0.6%+40) 0.01μA
measurement of frequency and capacitor capacity. Some have terminals). ■Current (mA / μA) %4-20mA measurement Resistance 500/5k/50k/500k/5M/50MΩ/99.99nS *1 ± (0.2%+6) 0.01Ω
■Capture (peak hold) 0.8ms in duration
added functions of maximum and minimum value hold and Capacitance 50n/500n/5μ/50μ/500μ/5m/25mF± (0.8%+3)*2 0.01nF
■MAX, MIN, AVE recording mode Temperature -50∼1000℃ (thermocouple K type) ± (0.3%+2) 0.1℃
relative value measurement as well as data hold and range hold

3.
■K type temperature -50℃∼1000℃ Frequency 10Hz∼200kHz ± (0.02%+4) 0.001Hz

functions. The PC series DMMs connect to a PC making it   ※Optional accessory K-AD is necessary. Logic frequency 5Hz∼2MHz ± (0.002%+4) 0.001Hz
No parallax reading error occurs as with an   ※K type temp. sensor K-250PC is included as a standard accessory. Duty cycle 0.1%∼99.99% ± (3d / kHz+2) 0.01%
possible to let a PC assume the function of expensive
analog multitester. ■Frequency measurement (AC sine wave only) dBm -29.83dBm∼54.25dBm ± (0.25dB+2) 0.01dB
recording meters and recorders. ■Logic frequency measurement, duty cycle Continuity Buzzer sounds at between 20Ω and 200Ω Open voltage : approx. 1.3V
Diode test Open voltage : approx. 3V
 measurement
■Conductance measurement Bandwidth V : 45Hz∼1kHz 1kHz∼20kHz(below 500V), A : 40Hz∼1kHz
■Dual display with backlight Fuse / Battery
11A/1000V IR20kA φ10×38
6LR61(9V)×1

Measurement ■Data hold, Range hold 0.4A/1000V IR30kA φ6.3×32


Four key points ■Relative value
Size / Mass H184×W86×D52mm/430g (including holster)

in choosing a suitable model


Standard Test Lead (TL-23a), Holster (H-700), Thermocouple K type (K-250PC),
■Auto power saving mode (30min.) (cancelable) accessories
included Instruction manual
■Optical Link USB interface (optional)
Voltage, Resistance measurement
Digital Multimeter
PC Link System,

Digital Multimeter
PC Link System,
1. What are the necessary
*1 nS(Conductance): High-value resistance of Giga-Ohms for leakage measurements.
Display : numeral display 50000 & 500000 selectable, Conductance is the inverse of Resistance, that is S=1/Ω or nS=1/GΩ
     bar graph 41 segments
Object to be measured In making measure- Sampling rate : 5 times/sec. for 50000 count, 1.25  
*2 Accuracy of film capacitor or equivalent with low leakage.
(dry cell, resistor, etc.)
measuring functions? ments, connect your         times/sec. for 500000 count, 60    Optional accessories
DCV DMM in parallel with         times/sec. for bar graph Software : PC Link7
Choose the necessary functions, except voltage and measurement an object to be Safety : IEC61010-1, IEC61010-31 CAT.III 600V Optical PC link cable : KB-USB7
resistance measurement. (including need for the measured. Do not Max./CAT. II 1000V Max., EN61326-1 Clamp probe : CL-22AD, CL33DC, CL3000
Battery life : Approx. 100h (alkaline battery) at DCV range
measurement of current (400mA, 10A, 12A, 20A), V
apply signals Temperature probe : T-300PC (PC Link software is necessary.)
exceeding the K-8-250∼800
capacitor, frequency, temperature and measurement of ACV
measurement maximum rated input K type adapter : K-AD
4-20mA, etc.) voltage.
Test lead : TL-21M, TLF-120

2. Other necessary functions


Carrying case : C-PC7
Clip adapter : CL-13a, CL-14, CL-15a, CL-DG3a, TL-9IC

Power source
Functions required differ depending on where the High accuracy & built-in memory (PC Link)
Analog Multitester

Analog Multitester
measurement is taken.
1) To record measured values concurrently with the Current measurement PC720M
process of measurement 87,328 points data logging in built-in memory
In making measure-
→ To fix data by the data hold function. Power source Load
ments, connect your ■4 digits 9999 count & 3-5/6 digits 6000 count Optional

→ To secure the test lead in the holster. DMM in series with ■AC True RMS
■Dual display with backlight
2) To check changes in measured values an object to be
■Automatic measurement for ACV/DCV/Ω under
measured.
→ Measurement of maximum values, minimum
Input
 low impedance PC720M Measuring range Best accuracy Resolution
Do not apply signals
impedance

values, and relative values. mA


exceeding the ■High speed bar graph DCV
ACV
60m/600m/9.999/99.99/999.9V
60m/600m/9.999/99.99/999.9V
± (0.06%+2)
± (0.5%+3)
0.01mV
0.01mV
10MΩ

3. For measurements of waveforms of


■Capacitance measurement
maximum rated input   ※Not suitable for measurement of condensers with large leak current. DCA 600μ/6000μ/60m/600m/6/10A ± (0.2%+4) 0.1μA
current. ■K type temperature -50℃∼1000℃ ACA 600μ/6000μ/60m/600m/6/10A ± (0.6%+3) 0.1μA
  ※Optional accessory K-AD is necessary. Resistance 600/6k/60k/600k/6M/60MΩ/99.99nS *1 ± (0.1%+3) 0.1Ω

non-sine waves, choose a model   ※K type temp. sensor K-250PC is included as a standard accessory. Capacitance 60n/600n/6μ/60μ/600μ/6m/25mF ± (0.8%+3)*2 0.01nF
Various Instruments

Various Instruments
supporting measurements by RMS
■Frequency measurement (AC sine wave only) Temperature -50∼1000℃ (thermocouple K type) ± (0.3%+2) 1℃
Frequency 15Hz∼50kHz ± (0.04%+4) 0.01Hz
■Logic frequency measurement, duty cycle
values. Diode test
 measurement
Logic frequency
Duty cycle
5Hz∼1MHz
0%∼100%
± (0.03%+4) 0.001Hz
± (3d / kHz+2) 0.01%
■Conductance measurement
In measuring distorted sine and non-sine waves (square
Continuity Buzzer sounds at between 20Ω and 300Ω Open voltage : approx. 1.2V
■MAX, MIN, MAX-MIN recording mode Diode test Open voltage : approx. 3.5V
wave, triangular wave, pulse), significant errors occur in When the black test ■Capture (peak hold) 1ms in duration
Cathode Anode lead is connected to Bandwidth V : 40∼3kHz 3kHz∼20kHz (below 99.99V), A : 40∼1kHz
measurement by models making measurements by the cathode side of the
■Data hold, Range hold
Fuse / Battery
11A/1000V IR20kA φ10×38
6LR61(9V)×1
■Relative value
mean values. diode and the red test
0.4A/1000V IR30kA φ6.3×32
■Auto power saving mode (30min.) (cancelable) Size / Mass H184×W86×D52mm/430g (including holster)
lead to the anode side,
There are two types of RMS values. ■Optical Link USB interface (optional) Standard Test Lead (TL-23a), Holster (H-700), Thermocouple K type (K-250PC),
the forward voltage accessories
included Instruction manual
AC-Coupled true RMS value : Adapted to measurements can be measured. In Data Logging Mode
of distorted sine and non-sine waves of the AC contrast, if the black ■87,328 data points in built-in memory *1 nS(Conductance): High-value resistance of Giga-Ohms for leakage measurements.
Conductance is the inverse of Resistance, that is S=1/Ω or nS=1/GΩ
AC + DC-coupled true RMS value : Adapted to measure- test lead is connected  (single display)
*2 Accuracy of film capacitor or equivalent with low leakage.
to the anode side of  43,664 data points in built-in memory
Accessories

Accessories
ments of waveform containing a DC component.
the diode and the red  (dual display) Optional accessories

4. Other functions test lead to the ■Selection of measurement interval Software : PC Link7
Diode  0.05s/0.1s/0.5s/1s/2s/3s/4s/5s/10s/15s/30s/
cathode side, the Optical PC link cable : KB-USB7
 60s/120s/180s/300s/600s Clamp probe : CL-22AD, CL33DC, CL3000
reverse voltage can be
There are other types including a function to transfer measured and "OL" ■Auto-standby mode when a sampling speed Temperature probe : T-300PC (PC Link software is necessary.)

data during measurement to a PC in real time and a display appears.  of 30s or longer is selected
K type adapter : K-AD
K-8-250∼800
■Export logged data to PC
function to record measured data in a built-in memory.   ※Optional accessory PC Link7 is necessary. Test lead : TL-21M, TLF-120
To transfer data to a PC, optional connecting cables Display : numeral display 9999 & 6000, bar graph 41
Carrying case : C-PC7
Clip adapter : CL-13a, CL-14, CL-15a, CL-DG3a, TL-9IC
and data retrieval software (PC Link or PC Link Plus) segments
are required in addition to a DMM of PC series. Sampling rate : 5 times/sec., 60 times/sec. for bar graph
Safety : IEC61010-1, IEC61010-31 CAT.III
600V Max./CAT. II 1000V Max.EN61326-1
Battery life : Approx. 100h (alkaline battery) at DCV range

20 www.sanwa-meter.co.jp www.sanwa-meter.co.jp 21
Clamp Meter
Clamp Meter

High accuracy & multi-function (PC Link) Digital Multimeter

PC710 PC773
True RMS, Dual Display 11000 Count
■4 digits 9999 count & 3-5/6 digits 6000 count Optional
Minimum resolution 0.01mV, 0.01Ω
Input
■Dual Display shows voltage/current and its ■4-1/2 digits 11000 count PC773 Measuring range Best accuracy Resolution impedance

 frequency, and AC components and DC ■0.28% best accuracy DCV 110m/1.1/11/110/1000V ± (0.28%+2) 0.01mV 10M∼
ACV 110m/1.1/11/110/1000V ± (0.7%+50) 0.01mV 100MΩ
 components of voltage/current Input ■AC True RMS
PC710 Measuring range Best accuracy Resolution impedance DCA 110μ/1100μ/11m/110m/11A ± (0.5%+4) 0.01μA
■AC True RMS ■Thermo plastic elastomer, high resistance
DCV 60m/600m/9.999/99.99/999.9V ± (0.06%+2) 0.01mV ACA 110μ/1100μ/11m/110m/11A ± (0.9%+20) 0.01μA
■EF(Electric Field) Detection to indicate signal 10MΩ  against drop shock
ACV 60m/600m/9.999/99.99/999.9V ± (0.5%+3) 0.01mV Resistance 110/1.1k/11k/110k/1.1M/11M/110MΩ ± (0.3%+6) 0.01Ω
 strength of electric field which surrounds DCA 600μ/6000μ/60m/600m/6/10A ± (0.2%+4) 0.1μA ■Maximum DC/AC 11A can be measured Capacitance 11n/110n/1.1μ/110μ/1.1m/11m/110mF ± (2.0%+20) 0.001nF
Tester
Insulation Resistance

Tester
Insulation Resistance
 current-carrying conductors ACA 600μ/6000μ/60m/600m/6/10A ± (0.6%+3) 0.1μA ■Continuity buzzer and LED Frequency 110Hz/1.1kHz/11kHz/110kHz/1.1MHz ± (0.01%+2) 0.1Hz
■Capture (peak hold) 1ms in duration Resistance 600/6k/60k/600k/6M/60MΩ/99.99ns *1 ± (0.1%+3) 0.1Ω ■Data hold, Range hold, Relative function Continuity Buzzer sounds and LED lights up at less than 30Ω Open Voltage: approx. 0.2V
■MAX, MIN, AVE recording mode Capacitance 60n/600n/6μ/60μ/600μ/6m/25mF± (0.8%+3)*2 0.01nF ■Auto power off function (30 min.) Diode test Open Voltage: approx. 0.2V
Temperature -50∼1000℃ (thermocouple K type) ± (0.3%+2) 1℃
■K type temperature -50℃∼1000℃ ■Optical link USB interface (optional) Bandwidth 45Hz∼100Hz(110mV range), 45Hz∼500Hz(1.1V range), 45Hz∼1kHz(11V range and above, ACA)
  ※Optional accessory K-AD is necessary. Frequency 15Hz∼50kHz ± (0.04%+4) 0.01Hz
315mA/1000V, breaking capacity 30kA
  ※K type temp. sensor K-250PC is included as a standard accessory. Logic frequency 5Hz∼1MHz ± (0.03%+4) 0.001Hz Display : numeral display 11000 Fuse / Battery R6×2
12A/1000V, breaking capacity 30kA
■Frequency measurement (AC sine wave only) Duty cycle 0%∼100% ± (3d / kHz+2) 0.01% Sampling rate : 4 times / sec.
Size / Mass H166×W82×D44mm/360g
■Logic frequency measurement, duty cycle Continuity Buzzer sounds at between 20Ω and 300Ω Open voltage : approx. 1.2V AC frequency bandwidth : Standard
Diode test Open voltage : approx. 3.5V 45∼100Hz(110mV range), 45∼500Hz(1.1V range), accessories Test lead (TL-25a), Instruction manual
 measurement included
Bandwidth V : 40Hz∼3kHz 3kHz∼20kHz(below 99.99V), A : 40Hz∼1kHz
45∼1kHz(11V range and avobe, ACA)
■Conductance measurement
Safety : IEC61010-1 (EN61010-1) CAT.III
■Dual display with backlight Fuse / Battery
11A/1000V IR20kA φ10×38
6F22(9V)×1
Optional accessories
0.4A/1000V IR30kA φ6.3×32 600V Max. / CAT.II1000V Max.
■Data hold, Range hold Software : PC Link 7 (This model works with PC Link 7 only.)
Size / Mass H184×W86×D52mm/430g (including holster)
■Relative value Clamp probe : CL-22AD, CL33DC, CL3000
Standard Test Lead (TL-23a), Holster (H-700), Thermocouple K type (K-250PC),
accessories Temperature probe : T-300PC (PC Link software is necessary.)
■Auto power saving mode (30min.) (cancelable) included Instruction manual
Optical PC link cable : KB-USB773 Test lead : TLF-120
■Optical Link USB interface (optional)
*1 nS(Conductance): High-value resistance of Giga-Ohms for leakage measurements. Carrying case : C-77, C-77H

Digital Multimeter
PC Link System,
Digital Multimeter
PC Link System,

Display : numeral display 9999 & 6000, bar graph 41 Conductance is the inverse of Resistance, that is S=1/Ω or nS=1/GΩ Clip adapter : CL-13a, CL-14, CL-15a, CL-DG3a, TL-9IC
segments *2 Accuracy of film capacitor or equivalent with low leakage.
Sampling rate : 5 times/sec., 60 times/sec. for bar graph
Safety : IEC61010-1, IEC61010-31 CAT.III Optional accessories
600V Max./CAT. II 1000V Max.EN61326-1 Software : PC Link7 A fuse of large
Battery life : Approx. 60h (manganese battery) Optical PC link cable : KB-USB7 breaking capacity (30kA) is
at DCV range Clamp probe : CL-22AD, CL33DC, CL3000 used to further improve
Temperature probe : T-300PC (PC Link software is necessary.) the safety.
K-8-250∼800
K type adapter : K-AD
Test lead : TL-21M, TLF-120
Carrying case : C-PC7
Clip adapter : CL-13a, CL-14, CL-15a, CL-DG3a, TL-9IC

High accuracy (PC Link) Data processing (PC Link)

Analog Multitester
Analog Multitester

Optional

PC700 Optional
PC20
Input
PC20 Measuring range Best accuracy Resolution impedance

Dual Display, Best Accuracy 0.06% AC adapter connectable for long haul measurement DCV 400m/4/40/400/1000V ± (0.5%+2) 0.1mV DCV:
10M∼
■4 digits 9999 count & 3-5/6 digits 6000 count ■3-3 / 4 digits 4000 count ACV 4/40/400/750V ± (1.2%+2) 0.001V
100MΩ
Input DCA 400μ/4000μ/40m/400m/4A/10A ± (1.5%+2) 0.1μA
■Maximum DC/AC voltage measurement PC700 Measuring range Best accuracy Resolution impedance ■0.5% best accuracy ACV:
ACA 400μ/4000μ/40m/400m/4A/10A ± (1.8%+2) 0.1μA 10M∼
 resolution 0.01mV DCV 60m/600m/9.999/99.99/999.9V ± (0.06%+2) 0.01mV
10MΩ
■Capacitance measurement
Resistance 400/4k/40k/400k/4M/40MΩ ± (1.2%+2) 0.1Ω 11MΩ
■Dual Display shows voltage/current and its ACV 60m/600m/9.999/99.99/999.9V ± (0.5%+3) 0.01mV  ※Not suitable for measurement of condensers with large leak current.
Capacitance 50n/500n/5μ/50μ/100μF ± (5%+6) 0.01nF
 frequency, and AC components and DC
DCA 600μ/6000μ/60m/600m/6/10A ± (0.2%+4) 0.1μA ■Data hold / Range hold
Continuity Buzzer sounds at between 10Ω and 120Ω. Open voltage : approx. 0.4V
ACA 600μ/6000μ/60m/600m/6/10A ± (0.6%+3) 0.1μA ■Safety cover for the 4・10A terminal
 components of voltage/current Diode test Open voltage : approx. 1.5V
Resistance 600/6k/60k/600k/6M/60MΩ ± (0.1%+3) 0.1Ω
■High speed bar graph ■Safety cap for AC adapter terminal
Capacitance 60n/600n/6μ/60μ/600μ/6m/25mF± (0.8%+3)* 0.01nF Bandwidth 40Hz∼500kHz (below 500V) 40Hz∼1kHz (ACA)
■Frequency measurement (AC sine wave only) ■Protective holster with wall hanger and lead holder
Frequency 15Hz∼50kHz ± (0.04%+4) 0.01Hz 0.5A/250V IR1500A φ5×20mm
■Logic frequency measurement, duty cycle Logic frequency 5Hz∼1MHz ± (0.03%+4) 0.001Hz ■Tilt stand Fuse / Battery
12.5A/250V IR125A φ6.3×32mm
R6×2

 measurement Duty cycle 0%∼100% ± (3d / kHz+2) 0.01% ■Optical link USB interface (optional) Size / Mass H167×W90×D48mm/330g (including holster)

Various Instruments
Various Instruments

Continuity Buzzer sounds at between 20Ω and 300Ω Open voltage : approx. 1.2V Standard
■Data hold, Range hold Display : numeral display 4000 accessories Test lead (TL-21a), Holster (H-70), Instruction manual
Diode test Open voltage : approx. 3.5V included
■Relative value Sampling rate : 3 times / sec.
■Auto power saving mode (30min.) (cancelable) Bandwidth V : 40Hz∼3kHz 3kHz∼20kHz(below 99.99V), A : 40Hz∼1kHz
11A/1000V IR20kA φ10×38 Optional accessories
■Optical Link USB interface (optional) Fuse / Battery 6F22(9V)×1
0.4A/1000V IR30kA φ6.3×32 Software : PC Link 7 Optical PC link cable : KB-USB20
Display : numeral display 9999 & 6000, bar graph 41 Size / Mass H184×W86×D52mm/430g (including holster) Clamp probe : CL-22AD, CL33DC, CL3000
segments Standard Temperature probe : T-300PC (PC Link software is necessary.)
accessories Test Lead (TL-23a), Holster (H-700), Instruction manual
Sampling rate : 5 times/sec., 60 times/sec. for bar graph included AC adapter : AD-71AC (100V), AD-72AC (220V)
Safety : IEC61010-1, IEC61010-31 CAT.III Test lead : TL-21M, TLF-120
*Accuracy of film capacitor or equivalent with low leakage.
600V Max./CAT. II 1000V Max.EN61326-1 Carrying case : C-PC10/S or C-SP
Battery life : Approx. 60h (manganese battery) Clip adapter : CL-13a, CL-14, CL-15a, CL-DG3a, TL-9IC
at DCV range
Optional accessories
Software : PC Link7
Optical PC link cable : KB-USB7
Clamp probe : CL-22AD, CL33DC, CL3000
Temperature probe : T-300PC (PC Link software is necessary.)

Accessories
Accessories

K type adapter : K-AD


Test lead : TL-21M, TLF-120
Carrying case : C-PC7
Clip adapter : CL-13a, CL-14, CL-15a, CL-DG3a, TL-9IC

22 www.sanwa-meter.co.jp www.sanwa-meter.co.jp 23
Clamp Meter
Clamp Meter

Standard type Multifunction

CD770 CD732
Input Input
CD770 Measuring range Best accuracy Resolution impedance CD732 Measuring range Best accuracy Resolution impedance

New Standard DCV 400m/4/40/400/600V ± (0.5%+2) 0.1mV DCV: High-speed bar graph & Cont. buzzer with LED DCV 600m/6/60/600/1000V ±(0.5%+2) 0.1mV DCV:
ACV 4/40/400/600V ± (1.2%+7) 1mV 10M∼ ACV 6/60/600/750V ±(1.2%+5) 0.001V 10M∼
■3-3/4 digits 4000 count 100MΩ ■6000 count 100MΩ
DCA 400μ/4000μ/40m/400mA ± (1.4%+3) 0.1μ ■Using fire-retarding materials for holster and DCA 600μ/6000μ/60m/600m/6/15A ±(1.5%+3) 0.1μA
■Easy to read large LCD ACV: ACV:
ACA 400μ/4000μ/40m/400mA ± (1.8%+5) 0.1μ ACA 600μ/6000μ/60m/600m/6/15A ±(1.8%+5) 0.1μA 10M∼
■Thermo plastic elastomer, high resistance 10M∼ circuit board 11MΩ
Resistance 400/4k/40k/400k/4M/40MΩ ± (1.2%+5) 0.1Ω 11MΩ Resistance 600/6k/60k/600k/6M/60MΩ ±(1.2%+4) 0.1Ω
 against drop shock ■Wide-range capacitance measurement
Capacitance 50n/500n/5μ/50μ/100μF ± (5%+10) 0.01nF Capacitance 40n/400n/4μ/40μ/400μ/4000μF ±(5.0%+6) 0.01nF
■Safety cap on current terminal (0.01nF to 3999μF)
Frequency 5/50/500/5k/50k/100kHz ± (0.3%+3) 0.001Hz Frequency 9.999/99.99/999.9/9.999k/99.99kHz ±(0.5%+3)
■Data hold / Range hold
■Data hold, Range hold, Relative function Continuity Buzzer sounds at between 0Ω and 85Ω (±45Ω). Open voltage: approx. 0.4V Duty cycle 20∼80% ±(0.5%+5)
■Safety cap on 6・15A terminal
■Continuity check, Diode test Diode test Open voltage: approx. 1.5V Continuity Buzzer sounds and LED lights up at between 10∼60Ω Open voltage : approx. 0.63V
■Protective holster with wall hanger and lead
Diode test Open voltage : approx. 2.7V
Tester
Insulation Resistance

Tester
Insulation Resistance
■Auto power off function (30min.) Bandwidth 40∼400Hz (sine wave) holder
Display : numeral display 4000
Fuse / Battery 0.5A/250V 1.5kA Φ5×20mm R6P×2 ■Auto Power Save (16min.) (cancelable) Bandwidth 45∼500Hz
Size / Mass H166×W82×D44mm/340g Fuse / Battery 0.4A/1000V 30kA φ6.3X32mm R6(1.5V) X 2
Sampling rate : 3 times / sec. 16A/1000V 30kA φ10X38mm
Standard
AC frequency bandwidth : 40∼400Hz (sine wave) accessories Test lead (TL-21a), Instruction manual
included Display : numeral display 6000, bar graph 61 segments Size / Mass H167×W90×D48mm/320g (including holster)
Standard
Sampling rate: 3 times/sec., accessories Test lead(TL-25a), Holster(H-70), Instruction manual
included
Optional accessories 30 times/sec., for bar graph
Clamp probe : CL-22AD, CL33DC, CL3000 Safety : EN61010-1, EN61010-2-030, EN61010-2-033 Optional accessories
Carrying case : C-77, C-77H CAT.III 600V / CATII DC1000V・AC750V Clamp probe : CL-22AD, CL3000, CL33DC
Clip adapter : CL-13a, CL-14, CL-15a, CL-DG3a, TL-9IC IEC61010-031 HV probe : HV-60
Test lead : TL-21M, TLF-120 Carrying case : C-SP
Clip adapter: CL-14

Multifunctional new standard RD701 only

RD700
CD771 RD701

Digital Multimeter
PC Link System,
Digital Multimeter
PC Link System,

Backlight & Cont. buzzer with LED High input impedance 1000MΩ
■3-3/4 digits 4000 count ■3-3 / 4 digits 4000 count
■0.3% best accuracy
Input
■Easy to read large LCD with Backlight CD771 Measuring range Best accuracy Resolution impedance RD700 / 701 Measuring range Best accuracy Resolution Input
impedance

■Large breaking capacity fuse 30kA DCV 400m/4/40/400/1000V ± (0.5%+2) 0.1mV DCV: ■AC True RMS ※RD701 only DCV 400m/4/40/400/1000V ± (0.3%+4) 0.1mV
10M∼ 10M∼
■1.5V battery check function ACV 4/40/400/1000V ± (1.2%+7) 1mV ■Capacitance measurement ACV 400m/4/40/400/1000V ± (1.5%+5) 0.1mV 1000MΩ
100MΩ   ※Not suitable for measurement of condensers with large leak
DCA 400μ/4000μ/40m/400m/4/10A ± (1.4%+3) 0.1μ   current. DCA 400μ/4000μ/40m/400m/4/10A ± (1.2%+3) 0.1μA
■Thermo plastic elastomer, high resistance ACV:
ACA 400μ/4000μ/40m/400m/4/10A ± (1.8%+5) 0.1μ 10M∼ ■K type temperature ACA 400μ/4000μ/40m/400m/4/10A ± (1.5%+4) 0.1μA
 against drop shock Resistance 400/4k/40k/400k/4M/40MΩ ± (1.2%+5) 0.1Ω 11MΩ  ※Optional accessory K-AD is necessary. Resistance 400/4k/40k/400k/4M/40MΩ ± (0.6%+4) 0.1Ω
■Safety cap on current terminal  ※K type temp. sensor K-250PC is included as a standard
Capacitance 50n/500n/5μ/50μ/100μF ± (5%+10) 0.01nF    accessory Capacitance 500n/5μ/50μ/500μ/3000μF ± (2.5%+6) 0.01nF
■Data hold, Range hold, Relative function Frequency 5/50/500/5k/50k/100kHz ± (0.3%+3) 0.001Hz ■Frequency measurement Temperature -20℃∼300℃ ± (2%+3) 1℃
■Continuity check, Diode test Continuity Buzzer sounds and LED lights up at between 0Ω and 85Ω (±45Ω). Open voltage: approx. 0.4V  ※Input voltage : 20VACrms and under Frequency 50Hz∼1MHz ± (0.5%+4) 0.01Hz
 ※Input signal : sign wave or square wave with 40%-70% duty
■Auto power off function (30min.) Diode test Open voltage: approx. 1.5V  ※Input sensitivity : 10Hz∼20kHz/0.9Vrms and above Continuity Buzzer sounds at between 20Ω and 120Ω. Open voltage : approx. 0.4V
Battery check Approximate value (30Ω load) 1.5V battery only : 20kHz∼500kHz/2.6Vp or 1.9Vrms and bove Diode Test Open voltage : approx. 1.6V
■Maximum 20A can be measured if the measurement : 500kHz∼1MHz/4.2Vp or 3Vrms and above

Analog Multitester
Analog Multitester

 time is less than 10 seconds. (Take 10 minutes or Bandwidth 40∼400Hz (sine wave) ■ADP function (for current sensor) Bandwidth 50∼500Hz
 longer intervals between measurements) 0.5A/1000V 30kA Φ6.35×32mm ■Max recording measurement 12.5A/500V IR20kA φ6.3×32mm
Fuse / Battery R6P×2 Fuse / Battery 6LF22 (9V)×1
10A/1000V 30kA Φ10×38mm ■Data hold / Range hold  ■Relative value 0.63A/500V IR200kA φ6.3×32mm
Display : numeral display 4000 Size / Mass H166×W82×D44mm/360g ■Auto power off (30min.) (cancelable) Size / Mass H179×W87×D55mm/460g (including holster)
Sampling rate : 3 times / sec. Standard ■Alarm for improper test lead insertion to current Standard
accessories Test lead (TL-23a), Instruction manual RD700 accessories
Test Lead (TL-23a), Thermocouple K type (K-250PC), Holster (H-50),
AC frequency bandwidth : 40∼400Hz (sine wave) included  terminal included Instruction manual
A fuse of large Safety : IEC61010-1 (EN61010-1) CAT.Ⅲ
breaking capacity (30kA) is ■Protective holster with wall hanger and lead
used to further improve
600V Max. / CAT.ⅡDC1000V Optional accessories  holder Optional accessories
the safety. Clamp probe : CL-22AD, CL33DC, CL3000 ■Tilt stand Clamp probe : CL-22AD, CL33DC, CL3000
HV probe : HV-60 HV probe : HV-60
Display : numeral display 4000 (Hz : 9999, capacitance : Temperature probe : K-8-800, K-8-650, K-8-300, K-8-500, K-8-250
Carrying case : C-77, C-77H      5000)
Clip adapter : CL-13a, CL-14, CL-15a, CL-DG3a, TL-9IC K type adapter : K-AD
Sampling rate : 3 times / sec. (Hz : 2 times / sec.) Test lead : TL-21M, TLF-120
Test lead : TL-21M, TLF-120
AC frequency bandwidth : 50∼500Hz Carrying case : C-CD
Clip adapter : CL-13a, CL-14, CL-15a, CL-DG3a, TL-9IC

True RMS new standard ALL-IN-ONE DMM


CD800a

Various Instruments
Various Instruments

CD772 Tough body cover


■3-3 / 4 digits 4000 count
Backlight & Temperature measurement
■0.7% best accuracy
■3-3/4 digits 4000 count ■Capacitance measurement Input
CD772 Measuring range Best accuracy Resolution Input
 *Not suitable for measurement of condensers with large leak current. CD800a Measuring range Best accuracy Resolution
■AC True RMS impedance
impedance

DCV 400m/4/40/400/1000V ± (0.5%+2) 0.1mV DCV: ■Frequency measurement (AC sine wave only) DCV 400m/4/40/400/600V ± (0.7%+3) 0.1mV DCV:
■Easy to read large LCD with Backlight 10M∼
10M∼ ACV 4/40/400/600V ± (1.6%+9) 0.001V
■Large breaking capacity fuse 30kA ACV 4/40/400/1000V ± (1.2%+8) 1mV
100MΩ
■Data hold / Range hold 100MΩ
DCA 40m/400mA ± (2.2%+5) 0.01mA
DCA 400μ/4000μ/40m/400m/4/15A ± (1.4%+3) 0.1μ ■Relative value ACV:
■K-type thermocouple temperature measure ACV: ACA 40m/400mA ± (2.8%+5) 0.01mA
ACA 400μ/4000μ/40m/400m/4/15A ± (1.8%+6) 0.1μ 10M∼
 ment -20℃∼300℃
10M∼ ■Auto power off (30min.) (cancelable) Resistance 400/4k/40k/400k/4M/40MΩ ± (1.5%+5) 0.1Ω 11MΩ
Resistance 400/4k/40k/400k/4M/40MΩ ± (1.2%+5) 0.1Ω 11MΩ
■Thermo plastic elastomer, high resistance ■Low power ohm (input voltage 0.4V) at continuity range Capacitance 50n/500n/5μ/50μ/100μF ± (5%+10) 0.01nF
Capacitance 50n/500n/5μ/50μ/100μF ± (5%+10) 0.01nF
■Solid & protective body cover that can also be Frequency 5Hz∼100kHz ± (0.5%+3)
 against drop shock Frequency 5/50/500/5k/50k/100kHz ± (0.3%+3) 0.001Hz
used as a tilt stand Duty cycle 20%∼80% ± (0.5%+5)
■Safety cap on current terminal Temperature -20℃∼300℃ ± (0.3%+30) 0.1℃
Continuity Buzzer sounds at between 10Ω and 120Ω. Open voltage : approx. 0.4V
Continuity Buzzer sounds and LED lights up at between 0Ω and 85Ω (±45Ω). Open voltage: approx. 0.4V ■Chip holder behind the body cover
■Data hold, Range hold, Relative function

Accessories
Accessories

Diode test Open voltage : approx. 1.5V


Diode test Open voltage: approx. 1.5V
■Continuity check, Diode test Display : numeral display 4000
Bandwidth 40∼400Hz
■Auto power off function (30min.) Bandwidth 45∼500Hz (4V range), 45∼1KHz (40V range and above) Sampling rate : 3 times / sec.
Fuse / Battery 0.5A/250V 1.5kA φ5.2×20 ceramic R6P×2
AC frequency bandwidth : 40∼400Hz
■Maximum 20A can be measured if the measurement Fuse / Battery
0.5A/1000V 30kA Φ6.35×32mm
R6P×2 Size / Mass H176×W104×D46mm/approx. 340g
 time is less than 10 seconds. (Take 10 minutes or 16A/1000V 30kA Φ10×38mm Standard
Size / Mass H166×W82×D44mm/360g accessories Hand strap , Instruction manual
 longer intervals between measurements) included
Standard
accessories Test lead (TL-25a), Thermocouple K type (K-250CD) Instruction manual
Display : numeral display 4000 included Optional accessories
Sampling rate : 3 times / sec. Clip adapter : CL-14, CL-15a, CL-DG3a, TL-9IC
A fuse of large
breaking capacity (30kA) is
AC frequency bandwidth : 45∼500Hz (4V range), 45∼ Optional accessories
1KHz (40V range and above) Clamp probe : CL-22AD, CL33DC, CL3000 HV probe : HV-60
used to further improve
Safety : IEC61010-1 (EN61010-1) CAT.Ⅲ Using cover as a tilt stand


the safety. Temperature probe : K-8-800, K-8-650, K-8-300, K-8-500, K-8-250
600V Max. / CAT.ⅡDC1000V K type adapter : K-AD
Carrying case : C-77, C-77H
Clip adapter : CL-13a, CL-14, CL-15a, CL-DG3a, TL-9IC
Test lead : TLF-120

24 www.sanwa-meter.co.jp www.sanwa-meter.co.jp 25
Clamp Meter
Clamp Meter

Pocket type Volt Meter


EF
PM11 KP1 (NCV)
Input
PM11 Measuring range Best accuracy Resolution impedance KP1 Measuring range Best accuracy Resolution
Tough but compact DMM DCV 400m/4/40/400/500V ± (0.8%+4) 0.1mV DCV: CAT.IV Volt tester DCV 5∼999.9V ±(0.7%+5) 0.1V
10M∼ ACV 5∼999.9V ±(1.7%+5) 0.1V
■3-3 / 4 digits 4000 count ACV 4/40/400/500V ± (2.3%+8) 0.001V
100MΩ ■AC True RMS
Resistance 400/4k/40k/400k/4M/40MΩ ± (2.0%+4) 0.1Ω Continuity Buzzer sounds at between 20kΩ and 500kΩ Open voltage: approx. 0.6V
■0.8% best accuracy ACV: ■Self test - checking failures of LCD,
Continuity Buzzer sounds at less than 35Ω. Open voltage : approx. 1.2V 10M∼
■Analog bar graph disconnection of a lead wire Bandwidth 45∼400Hz
Diode test Open voltage : approx. 3V 11MΩ
■Compact storage of test leads ■EF (Electric Field) detection Battery LR03 X 2
■Test lead can be snapped into a fixed position Bandwidth 45∼1kHz ■LCD with backlight & LED light for dark Size / Mass H130XW90XD30mm/approx. 205g
Battery Button battery LR-44×2 Standard Test leads (TL-35 : Test probe (red), TL-36 : Test lead (black),
 atop the case. place accessories
Size / Mass H117×W76×D18mm/approx. 117g included TL-A01 : Test probe (black), Instruction manual
■Auto data hold
Display : numeral display 4000, bar graph 40 segments Standard
accessories Instruction manual
Tester
Insulation Resistance

Tester
Insulation Resistance
Sampling rate : 1.3 times / sec., 13 times / sec. included ■Auto power off (1min.)
for bar graph Display : numeral display 9999
AC frequency bandwidth : 45∼1kHz Sampling rate : 6 times / sec. (ACV), 5 times / sec. (DCV)
Safety : IEC61010-1 CAT.Ⅲ300V Max. / CAT.Ⅱ500V Max. Optional accessories
Safety : IEC61010-1, IEC61010-2-030 CAT.IV600V /
Clip adapter : CL-15a, CL-DG3a CAT.III1000V, IEC61010-2-33, IEC61010-31

PM3
Input
PM3 Measuring range Best accuracy Resolution impedance

8.5mm thick body with multi-function Hybrid Digital Multimeter

Digital Multimeter
PC Link System,
Digital Multimeter
PC Link System,

DCV 400m/4/40/400/500V ± (0.7%+3) 0.1mV DCV:


10M∼
■3-3 / 4 digits 4000 count ACV 4/40/400/500V ± (2.3%+10) 0.001V
100MΩ
100A
PM33a
Resistance 400/4k/40k/400k/4M/40MΩ ± (2.0%+5) 0.1Ω
■0.7% best accuracy ACV:
Capacitance 5n/50n/500n/5μ/50μ/200μF ± (5.0%+10) 0.001nF 10M∼
■Capacitance measurement
Frequency 9.999/99.99/999.9/9.99k/60.00kHz ± (0.7%+5) 0.001Hz 11MΩ
  ※Not suitable for measurement of condensers with large leak current. Multimeter Clamp meter
■Frequency measurement (AC sine wave only)
Duty Cycle 0.1∼99% Hybrid pocket size DMM + Clamp meter
Continuity Buzzer sounds at less than 10∼120Ω. Open voltage : approx. 0.4V
■Duty cycle ■Lightweight approx. 160g
Diode Test Open voltage : approx. 1.5V
■Data hold ■Maximum / Minimum value hold PM33a Measuring range Best accuracy Resolution

■Relative value
Bandwidth 40∼400Hz ■ Current measurement with thin U-shaped current DCV 660m / 6.6 / 66 / 600V ± (0.7%+3) 0.1mV
Battery Coin type lithium battery CR2032 (3V)×1 sensor(7mm) at angles of 0 and 180 degrees ACV 660m / 6.6 / 66 / 600V ± (1.4%+6) 0.1mV
■Auto power off (15min.) (cancelable) Size / Mass H108×W56×D11.5mm/approx. 85g
■AC and DC currents measurable up to 100A DCA 100A ± (2.0%+5) 0.1A
Standard
Display : numeral display 4000 accessories Case holder (C-PM3), Instruction manual ■Data hold ACA 100A ± (2.0%+5) 0.1A
Sampling rate : 3 times / sec. included Resistance 660 / 6.6k / 66k / 660k / 6.6M / 66MΩ ± (0.9%+3) 0.1Ω
■Measurement of relative value
AC frequency bandwidth : 40∼400Hz Capacitance 6.6n / 66n / 660n / 6.6μ  / 66μ  / 660μ  / 6.6m / 66mF ± (5.0%+10) 0.001nF
Safety : IEC61010-1 CAT.Ⅱ DC AC500V Max. ■Auto power off Frequency 660 / 6.6k / 66kHz ± (0.5%+3) 0.1Hz
Optional accessories Duty cycle 20%∼80% ± (0.5%+5)
Safety : IEC61010-1 CAT.II 600V, CAT.III 300V
Clip adapter : CL-13a, CL-15a

Analog Multitester
Analog Multitester

Diode test Open voltage : approx. 3V


Continuity Buzzer sounds at below 30Ω . Open voltage : approx. 1.2V

Battery LR03 x 2
Size / Mass H130×W75×D19.9mm / approx160g (including Battery)
Clamp diameter φ10mm
Standard Instruction manual

PM7a
accessory

Optional accessories
Input
PM7a Measuring range Best accuracy Resolution impedance

Updated longtime seller DCV 400m/4/40/400/500V ± (0.7%+3) 0.1mV DCV:


Carrying case : C-DG3a
10M∼
■3-3 / 4 digits 4000 count ACV 4/40/400/500V ± (2.3%+10) 0.001V
100MΩ Clip adapter : CL-13a, CL-14, CL-15a, CL-DG3a, TL-9IC
Resistance 400/4k/40k/400k/4M/40MΩ ± (2.0%+5) 0.1Ω
■0.7% best accuracy ACV:
Continuity Buzzer sounds at less than 10∼120Ω. Open voltage : 0.4V 10M∼
■Range hold
Diode test Open voltage : approx. 1.5V 11MΩ
■Auto power off (15min.)
■Low power ohm (input voltage 0.4V) at Bandwidth 40∼400Hz
Battery Button battery LR-44×2
continuity range

Various Instruments
Various Instruments

Size / Mass H115×W57×D18mm/approx. 85g


■Power saving design Standard
accessories Instruction manual
Display : numeral display 4000 included
Sampling rate : 3 times / sec.
AC frequency bandwidth : 40∼400Hz
Optional accessories
Clip adapter : CL-14, CL-15a

AC current measurement Cables in a narrow space can be DC current measurement Easy to put in a shirt pocket
clamped for current measurement
PS8a
Input
PS8a Measuring range Best accuracy Resolution impedance

Solar charge battery DMM

Accessories
Accessories

DCV 400m/4/40/400/500V ± (0.7%+3) 0.1mV DCV:


10M∼
■3-3 / 4 digits 4000 count ACV 4/40/400/500V ± (2.3%+5) 0.001V
100MΩ
Resistance 400/4k/40k/400k/4M/40MΩ ± (2.0%+5) 0.1Ω
■0.7% best accuracy ACV:
Continuity Buzzer sounds at less than 10∼120Ω. Open voltage : 0.4V 10M∼
■Range hold
Diode test Open voltage : approx. 1.5V 11MΩ
■Auto power off (15min.)
■Low power ohm (input voltage 0.4V) at    Bandwidth 40∼400Hz
Battery Amorphous solar battery + manganese dioxide lithium secondary battery
 continuity range
Size / Mass H115×W57×D18mm/approx. 85g
■Power saving design Standard
accessories Instruction manual
Display : numeral display 4000 included
Sampling rate : 3 times / sec.
AC frequency bandwidth : 40∼400Hz
Optional accessories
Clip adapter : CL-14, CL-15a

26 www.sanwa-meter.co.jp www.sanwa-meter.co.jp 27
Analog Multitesters (circuit testers)

Clamp Meter
Analog multitesters basically make measurements of DC voltage, Easy to read the mean value of values changing
AC voltage, DC current and resistance. Except some special in short cycles.
products, they have no function to measure the AC current. * A digital tester does not give stable value determination.
Characteristics of recent analog multitesters include the
extended measuring range function (particularly for fine voltage
and current) with an amplifier installed, the function to allow the No need for the operating power supply except
measurement of capacitor capacity, and the zero-center meter for resistance range (excluding Model EM7000

Tester
Insulation Resistance
function. To enhance operability and usability, some products integrating an amplifier, and CX506a integrating
include the auto range function, automatic polarity switching an oscillator) and zero-center function.
function, and a structure integrating a case to allow the storage
of a test lead. There are some testers that allow the measure-
ment of hFE (DC current amplification factor) of a transistor and Suited for judgment based by intuition (in
temperature measurement using a temperature sensor, which is continuity test etc.).
offered as an optional accessory.

1. What are the necessary measuring func-

Digital Multimeter
PC Link System,
Check the range before making a measurement
Most problems with a tester are caused by overcurrent
tions?
and drop of the tester. Failures due to overcurrent are
Choose the necessary measuring functions in addition to voltage
most frequently caused by voltage applied to a current
and resistance.
range and resistance range with lower internal resistance
→ Need for the measurement of current (0.25A, 0.3A, 30A), DC
(thereby causing overcurrent of tens to hundreds times to
  only.
run through the circuit). Although some testers include a
→ Measurements for remaining dry battery capacity, capacitor,  
meter protector and a circuit protector using a diode, it is
  and frequency.
recommended to check the range before measuring.
→ Measurement of DC high voltage with the use of an optional
  accessory. For measuring unknown values
In measuring unknown current and voltage values, find an
2. Other necessary functions

Analog Multitester
Analog Multitester

approximate value at the maximum range first and then


make adjustments to the optimum range (1000V to 250V
1) The needle occasionally swings to the opposite direction in range in case of voltage measurement). This method
DC voltage measurement. prevents a failure caused by incorrect range adjustment.
→ Check the polarity by the zero-center meter function. * Do not change the range during measurement.

2) Hard to check for continuity.


→ Use an LED light-up type in noisy places
→ Use a buzzer type to verify with sounds.

3. Graduation of scale

Various Instruments
There are two general types of graduation of the measuring
range:
① 2.5, 5, 10, 50, 250, 500V
② 3, 12, 30, 120, 600V

For measurement of a car battery (24V), measurement in the 30V


range of ② is suitable. Choose a type suitable for your intended
application.

4. Other functions

Accessories
Other types are furnished with an auto range function allowing
the automatic optimal setting of voltage and resistance. There are
also types integrating a transistor transmitter and others integrat-
ing a current-limiting fuse with breaking capacity of 100kA for
enhanced safe operation.

28 29
Clamp Meter

Clamp Meter
FET Tester Multifunctional model
EM7000 SH-88TR
High sensitivity for measurement of lower EM7000 Measuring range Accuracy Zero center meter (NULL) SH-88TR Measuring range Accuracy

capacitance DCV 0.3/1.2/3/12/30/120/300/1000V ±3% of full scale DCV 0.12/3/12/30/120/300/1200V (20kΩ/V) ±2.5% of full scale
■ Total 35 wide ranges (22ch sw + additional (NULL) ±6/15/60/150/600V (40kΩ/V) ±2.5% of full scale
±DCV ±0.15/0.6/1.5/6/15/60/150/600V ±7% of full scale
■ High input impedance (DCV2.5∼12MΩ/V), and fuctions) ACV 3/12/30/120/300/1200V (9kΩ/V) ±3% of full scale
ACV 3V (approx. 2.5MΩ)/12V (approx. 1.1MΩ)
0.12μA range (DCA) rms (50 / 60Hz) 30V (approx. 800kΩ)/120/300V (approx. 800kΩ)/ ±3% of full scale ■ Capacitance measurement 1μF∼1F (3V : ±5%)

■ Bandwidth 40Hz∼1MHz AC sign wave 750V (approx. 10MΩ) ■ LED for continuity check DCA 50μ / 3m/ 30m/ 0 .3 A ±2.5% of full scale
Sine wave:8.4V (approx. 2.5MΩ/V)/ 33V (approx. 1.1MΩ/V) Resistance 3k/30k/300k/3M/30MΩ ±3% of arc
■ Rectangular pulse P-P (Peak to Peak) ACV ±5% of full scale Optional accessories
P-P 84V (approx. 800MΩ/V)/330/840V (approx. 800kΩ/V) dB -10∼+63dB ±3% of full scale
measurement (duty cycle 20% and above) (3V : ±5%)
Square symmetric wave:8.4V (2.5MΩ/V) ±6% of full scale HV probe : HV-10
■ Wide ohm range 0.2Ω∼200MΩ Triangular symmetric wave:8.4V (2.5MΩ/V) ±6% of full scale Carrying case : C-YS Capacitance 1000μ/0.01/0.1/1F
Clip adapter : CL-14, CL-15a, CL-DG3a, TL-9IC Continuity LED : emitting light at 10Ω or less. Open voltage : 3V
Tester
Insulation Resistance

Tester
Insulation Resistance
Bandwidth : 40Hz∼1Mhz (12V range and below) DCA 0.12μ/0.3m/3m/30m/300m/6A ±3% of full scale
DCA (NULL) ±0.06μ/±0.15m/1.5m/15m/150mA ±7% of full scale hFE probe : HFE-6T hFE 1000 at ×10 range (optional probe "HFE-6T" is necessary) ー
Optional accessories ACA 6A ±3% of full scale Test lead : TL-91M
Bandwidth 40∼20kHz (less than 30V : ±3%) 30∼100kHz (less than 30V : ±1dB)
HV probe : HV-60 Resistance 2k/20k/200k/2M/20M/200MΩ ±3% of arc
Battery R6P×2, 6F22×1
Carrying case : C-CA dB -10∼+51dB ±3% of arc
Fuse φ5.2×20mm (250V/0.5A)
Clip adapter : CL-13a, CL-14, CL-15a, CL-DG3a, TL-9IC Bandwidth 40Hz∼1MHz (below 12V range) Size / Mass H150×W100×D36mm/approx. 280g
Test lead : TL-21M, TLF-120 Battery R6P 1.5V×2, 6F22 9V×1 Standard
Test lead (TL-61), Instruction manual
Fuse φ5.0×20mm ceramic (250V / 0.5A) accessories included
φ5.0×20mm ceramic (250V / 6.3A) The value in ( ) at DCV and ACV is input resistance.
Size / Mass H165×W106×D46mm / approx. 375g
Standard acce-
Test lead (TL-21a), Spare fuse, Instruction manual
ssories included
The value in ( ) at DCV and ACV is input resistance.
High input impedance
DCA
AU-32 ACA
AU-31
Digital Multimeter
PC Link System,

Digital Multimeter
PC Link System,
AU-32 Measuring range Accuracy
DCV ±250m (approx. 1MΩ/V)/2.5/10/50/250/500V (10MΩ/V) ±3% of full scale
Auto range, High input impedance ACV 250m (approx. 1MΩ/V)/2.5/10/50/250/500V (10MΩ/V) ±3% of full scale
Multifunctional model ■ Auto range selection (V, Ω) DCA ±250μ/2.5m/25m/250m/2.5A ±3% of full scale
ACA 250μ/2.5m/25m/250m/2.5A ±3% of full scale

CX506a
■ Auto polarity
Resistance 20k/200k/2M/20M/200MΩ ±3% of arc
■ High input impedance 1∼10MΩ dB -10/+10/+22/+36/+50/+56dB ー
■ Series capacitor input ※AU-31 ACV only
Capacitor & Transistor checker (built-in- CX506a Measuring range Accuracy Bandwidth 40∼10kHz (0.25V : ±5%), 40∼600Hz (2.5V∼ : ±5%)
■ Auto 0Ω adjustment
oscillator) DCV 120m (4kΩ)/3/12/30/120 120m : ±4% Battery R03×4
300 (50kΩ/V)/1000V (15kΩ) ±2.5% of full scale ■ Inner battery check Fuse φ5.2×20mm (250V/0.3A)
■ 26ch switch, wide range measurement ±3% of full scale ■ DC / AC auto selection ※AU-32 only Size / Mass H48×W110×D124mm/approx. 290g
■ Capacitance measurement 50pF∼2000μF ACV 3/12/30/120/300/750V (8kΩ/V) (Less than 12V ■ 5 ranges DC / AC current ※AU-32 only Standard
range : ±4%) Test lead (TL-61), Instruction manual
■ High input impedance 50kΩ / V (DC3∼300Vrange) Bandwidth : 40∼10kHz (0.25V : ±5%), 40∼600Hz
accessories included
DCA 30μ/0.3m/3m/30m/0.3A ±2.5% of full scale
■ Switchable DC polarity (2.5V and above : ±5%)
The value in ( ) at DCV and ACV is input resistance.
Resistance 5k/50k/500k/5M/50MΩ ±3% of arc AU-31 Measuring range Accuracy
Bandwidth : 40Hz∼30kHz (3V and 12V), Capacitance C1 : 50p∼0.2μF  C2 : 0.01μ∼20μF C1/C2 : 40∼10kHz (0.3V : ±5%), 40∼1kHz
DCV ±300m (approx. 1MΩ/V)/3/12/60/300/1000V (10MΩ/V) ±3% of full scale

Analog Multitester
Analog Multitester

40Hz∼10kHz (30V range) C3 : 1∼2000μF ±6% of arc (3V and above : ±4%) ACV 300m (approx. 1MΩ/V)/3/12/60/300/1000V (10MΩ/V) ±3% of full scale
hFE (DC Current
Optional accessories Amplification Factor) Transistor hFE:0∼1000 ー Optional accessories DCA ±300m/3A ±3% of full scale
ACA 300m/3A ±3% of full scale
HV probe : HV-60 AU-32 HV probe : HV-50
Bandwidth 40∼30kHz (12V:40Hz∼30kHz 30V∼ : 40Hz∼10kHz) Resistance 20k/200k/2M/20M/200MΩ ±3% of arc
Carrying case : C-CA Carrying case : C-SP
Battery R6P×2, 6F22×1 dB -9/+11/+23/+37/+51/+62dB ー
Clip adapter : CL-13a, CL-14, CL-15a, CL-DG3a, TL-9IC Clip adapter : CL-14, CL-15a, CL-DG3a, TL-9IC
Fuse φ5.0×20mm
Test lead : TL-21M, TLF-120 Test lead : TL-91M Bandwidth 40∼10kHz (0.3V : ±5%) 40∼1kHz (3V∼ : ±4%)
(250V/0.5A) arc-extingishing material in ceramic tube
Battery R03×4
Size / Mass H165×W106×D46mm/approx. 370g
Fuse φ5.2×20mm (250V/0.5A)
Standard Test lead (TL-21a), Clip lead (CL-506a) Size / Mass H48×W110×D124mm/approx. 290g
accessories included Instruction manual, Spare fuse
Standard
The value in ( ) at DCV and ACV is input resistance. Test lead (TL-61), Instruction manual
accessories included
The value in ( ) at DCV and ACV is input resistance.
Various Instruments

Various Instruments
Drop shock proof meter

YX-361TR YX360TRF
Best seller drop shock proof meter YX360TRF Measuring range Accuracy
Wide measurement range YX-361TR Measuring range Accuracy
DCV 0.1V (20kΩ / V) ±5% of full scale
DCV 0.1/0.5/2.5/10/50/250/1000V(20kΩ/V) ±2.5% of full scale ■ Drop shock proof meter
■ Total 35 wide ranges (24ch sw + additional (NULL) ±5/25V (40kΩ/V) ±2.5% of full scale
(NULL) 0.25 / 2.5 / 10 / 50 (20kΩ / V) / 250 / 1000V(9kΩ / V) ±3% of full scale
fuctions) ■ Null (zero center) meter ±5 / ±25 in DCV ±5 / 25V (40kΩ / V) ±5% of full scale
ACV 2.5/10/50/250/1000V (9kΩ/V) ±3% of full scale
■ High resistance up to 200MΩ with low voltage ACV 10 / 50 / 250 / 750V (9kΩ / V) ±4% of full scale
■ ±DCV zero center meter (3V : ±5%)
■ Protective body cover DCA 50μ / 2.5m /25m / 0.25A *1±5% of full scale
■ LED for continuity check DCA 50μ/2.5m/25m/0.25A ±2.5% of full scale
■ Capacitance, dB, Li measurement Resistance 2k / 20k / 200k / 2MΩ (X1 / X10 / X100 / X1k) ±3% of arc
■ OUTPUT terminal (series capacitor terminal) Resistance 2k/20k/200k/2M/20MΩ ±3% of arc
200MΩ (X100k) ±5% of arc
■ Battery check dB -10∼+62dB ±3% of full scale Bandwidth : 30∼100kHz (AC10V)
Load current (LI) 0∼150m / 15m / 1.5m / 150μ / 1.5μA
(3V : ±5%)
Optional accessories Continuity LED : emitting light at 10Ω or less. Open voltage : 3V Optional accessories Capacitance 10μF *2
dB -10dB∼+22dB (for 10VAC) ∼+62dB ー
Battery check 1.5V hFE probe : HFE-6T
HV probe : HV-10 DC high voltage DC25kV (optional probe "HV-10T" is necessary) ー
Accessories

Accessories
hFE 1000 at ×10 range (optional probe "HFE-6T" is necessary) ー Clip adapter : CL-14, CL-15a, CL-DG3a, TL-9IC
Carrying case : C-YS hFE 1000 at ×10 range (optional probe "HFE-6T" is necessary) ー
Clip adapter : CL-15a, CL-14, CL-DG3a, TL-9IC Bandwidth 40∼20kHz (less than 50V : ±3%)
High voltage probe : HV-10T
Battery R6 (IEC) or UM-3(1.5V)×2
hFE probe : HFE-6T Battery R6P×2, 6F22×1
Fuse φ5.2×20mm (250V / 0.5A)
Test lead : TL-91M Fuse φ5.2×20mm (250V / 0.5A)
Size / Mass H159.5×W129×D41.5mm / approx. 320g
Size / Mass H150×W100×D37mm / approx. 290g
Standard
Standard Instruction manual, Hand strap
Test lead (TL-61), Instruction manual accessories included
accessories included
The value in bracket at DCV and ACV is input resistance.
The value in ( ) at DCV and ACV is input resistance. *1 Not including the resistance of fuse.
*2 Pointer indication of the maximum move by charged current in the capacitor.
Tension
Spring
Taut-Band

30 www.sanwa-meter.co.jp www.sanwa-meter.co.jp 31
Clamp Meter

Clamp Meter
Drop shock proof meter Slim compact AMT

SP21 CP-7D
SP21 Measuring range Accuracy CP-7D Measuring range Accuracy
Continuity check buzzer DCV 0.3 (5kΩ)/3/12/30/120/600V (20kΩ/V) ±3% of full scale
23mm thick small size DCV 0.25/2.5/10/50/250/500V (4kΩ/V) ±3% of full scale
(NULL) ±6/30V (20kΩ/V) ±5% of full scale 10/50/250/500V (4kΩ/V)
■ Drop shock proof taut-band meter ■ Wide scale panel with mirror ACV ±4% of full scale
ACV 12/30/120/300/600V ±3% of full scale DCA 0.25m/25m/500mA ±3% of full scale
■ ±DCV zero center meter ■ Affixed test leads providing better safety
DCA 60μ/30m/0.3A ±3% of full scale Resistance 2k/20k/1MΩ ±3% arc
■ Fuse and diode protection Resistance 2k/20k/2MΩ ±3% of arc
■ High-precision, non-flammable, smokeless Load current (LI) 0∼74mA/7.4mA/150μA ー
■ Battery check Capacitance 500μF *1 metal-oxide film resistor Battery check 0.9∼1.5V ー
■ Tilt stand Continuity Buzzer sounds at less than approx. 10Ω. Open voltage: 3V ■ Battery check dB -20∼36dB ー

Bandwidth : 40∼100kHz (AC12V) ■ Fuse and diode circuit protection


Bandwidth 40∼100kHz (AC12V) Bandwidth 30∼100kHz (AC10V) 30∼20kHz (AC50V)
Battery R6P×2 Bandwidth : 30∼100kHz (AC10V), Battery R6P×1
Optional accessories
Tester
Insulation Resistance

Tester
Insulation Resistance
Fuse φ5×20mm (250V/0.5A) 30∼20kHz (AC50V) Fuse φ5.2×20mm (250V/0.5A)
HV probe : HV-20 Size / Mass H144×W99×D41mm/approx. 270g Size / Mass H119×W85×D23mm/approx. 140g
Carrying case : C-SPH or C-SP Standard
Test lead (TL-21a), Instruction manual
Optional accessories Standard
Test lead (TL-84), Instruction manual
Clip adapter : CL-13a, CL-14, CL-15a, CL-DG3a, TL-9IC accessories included Carrying case : C-CP accessories included
Test lead : TL-21M, TLF-120 The value in ( ) at DCV and ACV is input resistance. Clip adapter : CL-14, CL-15a, CL-DG3a, TL-9IC The value in ( ) at DCV and ACV is input resistance.
*1 Pointer indication of the maximum move by charged current in the capacitor.

Optional

SP20
SP20 Measuring range Accuracy
DC high voltage & temperature measurable DCV 0.25/2.5/5/10/50/100V (20kΩ/V)/500V (9kΩ/V) ±3% of full scale
Digital Multimeter
PC Link System,

Digital Multimeter
PC Link System,
ACV 10/50/250/500V (9kΩ/V) ±3% of full scale
■ 20ch measurement ranges
AP33
DCA 50μ/2.5m/25m/0.25A ±3% of full scale
■ Capacitance measurement 500μF Resistance 2k/20k/200k/2MΩ ±3% of arc
■ Tilt stand Capacitance 500μF *1 AP33 Measuring range Accuracy
■ DC high voltage and temperature measurement DC high voltage DC25kV (Optional probe "HV-10" is necessary) ー Small pocket size DCV 10/50/250/500V (2kΩ/V) ±5% of full scale
(with optional accessories) Temperature -20 ∼ +200℃ (Optional probe "T-THP" is necessary) ±3% (T-THP) ACV 50/250/500V (2kΩ/V) ±5% of full scale
■ Elastomer material absorbs shock from fall
Battery check 1.5V/9V ー
Bandwidth : 40∼100kHz (AC10V) Bandwidth 40∼100kHz (AC10V) ■ High-durability nylon-woven copper lead DCA 25m/250mA ±5% of full scale
Battery R6P×2 ■ Using elastomer material improves flexibility and
Optional accessories Fuse φ6.3×30mm (250V/0.5A) reduces the stress on the lead wire and the
Resistance 5k/500kΩ ±3% arc

HV probe : HV-10 Size / Mass H144×W99×D41mm/approx. 270g Bandwidth 40∼10kHz (less than 50V)
probe when bent.
Temperature probe : T-THP Standard Battery R03×1
Test lead (TL-61), Instruction manual Bandwidth : 40∼10kHz (50V and below)
accessories included Fuse φ5×20mm (250V/0.5A)
Carrying case : C-SPH or C-SP
The value in ( ) at DCV and ACV is input resistance. Size / Mass H126×W87×D30mm/approx. 185g
Clip adapter : CL-14, CL-15a, CL-DG3a, TL-9IC
*1 Pointer indication of the maximum move by charged current in the capacitor.
Test lead : TL-91M, TLF-120 Standard
Instruction manual
accessories included
The value in ( ) at DCV and ACV is input resistance.

Analog Multitester
Analog Multitester

SP-18D
SP-18D Measuring range Accuracy
Protective body cover DCV 0.3/3/12/30/120/600V (2 0 k Ω /V) ±3% of full scale
ACV 12/30/120/300/600V (9kΩ/V) ±3% of full scale
■ Low power ohm (3V) measurement upto 200MΩ
DCA 60μ/30m/0.3A ±3% of full scale
■ Capacitance measurement 0.01μF∼1000μF Resistance 2k/20k/2M/200MΩ ±3% of arc
■ LED check by 3V terminal voltage at resistance Battery check 1.5V/1.5V Coin battery ー
range Capacitance 1000μF *1
■ Battery check
Bandwidth 30∼70kHz (AC 12V) 30∼20kHz (AC 30V)
For power line
■ Protective body cover Battery R6P×2
Bandwidth : 30∼80kHz (AC12V), 30∼20kHz
(AC30V)
Fuse
Size / Mass
φ5.2×20mm (250V/0.5A)
H159.5×W129×D41.5mm / approx. 320g VS-100 (with case)
Various Instruments

Various Instruments
VS-100 Measuring range Accuracy
Standard
Instruction manual Current-limiting fuse, 100kA breaking
Optional accessories accessories included DCV 10/50/250/500V (4kΩ/V) ±3% of full scale
The value in ( ) at DCV and ACV is input resistance. capacity, is installed. ACV 10/50/250/500V (4kΩ/V) ±3% of full scale
Clip adapter : CL-14, CL-15a, CL-DG3a, TL-9IC *1 Pointer indication of the maximum move by charged current in the capacitor. Resistance 2k/20k/2MΩ ±3% arc
■ For lower voltage circuit (500V and below) with
large capacitance Bandwidth 40∼10kHz (less than AC50V)
Battery R6P×2
■ Current-limiting fuse that can interrupt 100kA, is
Current-limiting fuse 600V/3A, Breaking capacity 100kA
installed. Fuse
Glass-tube fuse φ6.3×30mm 0.25A/250V, Breaking capacity 100A

TA55 ■ All renges are protected from input voltage upto


500V
Size / Mass
Standard
H144×W96×D56mm/approx. 395g
Test lead (TL-100-0M), Carrying case (C-VS),

30A range for automotive TA55 Measuring range Accuracy ■ Carrying case accessories included Instruction manual
The value in ( ) at DCV and ACV is input resistance.
DCV 0.3/3/16/30/60V (20kΩ/V) ±3% of full scale Bandwidth : 40∼10kHz (50V and below)
■ High level panel visibility ACV 30/120/300V (9kΩ/V) ±4% of full scale
■ Continuity check buzzer DCA 0.5/3/30A ±5% of full scale
■ Tilt-stand Resistance 2k/20k/200k/2MΩ ±3% of arc
■ Measurable upto DC30A / DC300A with optinal
Accessories

Accessories
Continuity Buzzer sounds at less than approx. 70Ω. Open voltage : 3V
clamp probe
Bandwidth 40∼5kHz
Bandwidth : 40∼5kHz Battery R6P×2
Fuse φ6.3×30mm (250V/3A)
Optional accessories Size / Mass H142×W97×D38mm/approx. 300g
Clamp probe : CL33DC Standard Test lead (TL-91), Instruction manual
accessories included
Carrying case : C-SPH or C-SP
Clip adapter : CL-14, CL-15a, CL-DG3a, TL-9IC The value in ( ) at DCV and ACV is input resistance.

Test lead : TL-91M, TLF-120

32 www.sanwa-meter.co.jp www.sanwa-meter.co.jp 33

You might also like