Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

18/9/2019 D4G XL & D4G LGP Track-Type Tractors TLX00001-UP (MACHINE) POWERED BY 3046 Engine(SEBP3826 - 54) - Documentation

Previous Screen
Welcome: p230tav
Product: TRACK-TYPE TRACTOR
Model: D4G TRACK-TYPE TRACTOR TLX01086
Configuration: D4G XL & D4G LGP Track-Type Tractors TLX00001-UP
(MACHINE) POWERED BY 3046 Engine

Troubleshooting
D3G, D4G and D5G Track-Type Tractors Electrohydraulic
Media Number -RENR7313-02 Publication Date -01/03/2015 Date Updated -18/03/2015

i01920396

Diagnostic Code List


SMCS - 7569

Use the Caterpillar Electronic Technician in order to determine the diagnostic codes for the ECM. After
determining the diagnostic codes, refer to the corresponding test procedure for more information. Perform the
procedure that corresponds to the diagnostic code (CID and FMI). The following table is a list of possible
diagnostic codes for the ECM.

Table 1
Diagnostic Codes For Machine ECM (MID No. 079) (1)
For troubleshooting, see the procedure with the same CID And FMI No.
CID / FMI Description
CID 0017 Solenoid Valve (Fuel Shutoff)
FMI 03 Voltage above normal or shorted high.
FMI 05 Current below normal or open circuit.
FMI 06 Current above normal or grounded circuit.
CID 0041 Sensor Power Supply (8 DCV)
FMI 00 Data Valid but above normal operating range.
CID 0070 Rocker Switch (Parking Brake)
FMI 02 Data erratic, intermittent, or incorrect.
FMI 01 Data Valid but below normal operating range.
CID 0110 Temperature Sensor (Engine Coolant)

FMI 03 Voltage above normal or shorted high.


CID 0133 Solenoid Valve (Transmission Pilot Pressure)

https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/mediasearch/mediaheaderinfoframeset.jsp&calledpage=/… 1/4
18/9/2019 D4G XL & D4G LGP Track-Type Tractors TLX00001-UP (MACHINE) POWERED BY 3046 Engine(SEBP3826 - 54) - Documentation

FMI 03 Voltage above normal or shorted high.


FMI 05 Current below normal or open circuit.
FMI 06 Current above normal or grounded circuit.
CID 0153 Speed Sensor (Right Track)
FMI 08 Abnormal frequency, pulse width, or period.
CID 0154 Speed Sensor (Left Track)
FMI 08 Abnormal frequency, pulse width, or period.
CID 0168 Electrical System
FMI 03 Voltage above normal or shorted high.
FMI 04 Voltage below normal or shorted low.
CID 0190 Engine Speed Sensor

FMI 08 Abnormal frequency, pulse width or period.


CID 0444 Magnetic Switch (Start Relay)

FMI 03 Voltage above normal or shorted high.


FMI 05 Current below normal or open circuit.

FMI 06 Current above normal or grounded circuit.


CID 0468 Position Sensor (Service Brake Pedal)

FMI 03 Voltage above normal or shorted high.


FMI 04 Voltage below normal or shorted low.

FMI 08 Abnormal frequency, pulse width or period.


CID 0617 Relay (Inlet Air Heater)

FMI 03 Voltage above normal or shorted high.


FMI 05 Current below normal or open circuit.

FMI 06 Current above normal or grounded circuit.


FMI 13 Out of calibration.

CID 0650 Harness Code


FMI 12 Bad device or component failed.

CID 0681 Solenoid Valve (Parking Brake)

FMI 03 Voltage above normal or shorted high.


FMI 06 Current above normal or grounded circuit.

FMI 05 Current below normal or open circuit.


https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/mediasearch/mediaheaderinfoframeset.jsp&calledpage=/… 2/4
18/9/2019 D4G XL & D4G LGP Track-Type Tractors TLX00001-UP (MACHINE) POWERED BY 3046 Engine(SEBP3826 - 54) - Documentation

CID 0817 ECM Internal Backup Battery

FMI 04 Voltage below normal or shorted low.


CID 1482 Sensor Power Supply (10 DCV)

FMI 00 Data Valid but above normal operating range.


FMI 01 Data Valid but below normal operating range.

CID 1693 Position Sensor (Deceleration Pedal)


FMI 03 Voltage above normal or shorted high.

FMI 04 Voltage below normal or shorted low.


FMI 08 Abnormal frequency, pulse width or period.

FMI 13 Out of calibration.


CID 1699 Position Sensor (Forward/Neutral/Reverse)

FMI 03 Voltage above normal or shorted high.


FMI 04 Voltage below normal or shorted low.

FMI 08 Abnormal frequency, pulse width or period.


FMI 13 Out of calibration.

CID 1700 Position Sensor (Joystick)


FMI 03 Voltage above normal or shorted high.

FMI 04 Voltage below normal or shorted low.


FMI 08 Abnormal frequency, pulse width or period.

FMI 13 Out of calibration.


CID 1701 Switch (Machine Acceleration)

FMI 02 Data erratic, intermittent, or incorrect.


CID 1702 Switch (Machine Deceleration)

FMI 02 Data erratic, intermittent, or incorrect.


CID 1703 Proportional Solenoid Valve (Forward Left Drive Pump)

FMI 03 Voltage above normal or shorted high.

FMI 05 Voltage below normal or shorted low.


FMI 06 Failure mode not identifiable.

CID 1704 Proportional Solenoid Valve (Reverse Left Drive Pump)

FMI 03 Voltage above normal or shorted high.

https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/mediasearch/mediaheaderinfoframeset.jsp&calledpage=/… 3/4
18/9/2019 D4G XL & D4G LGP Track-Type Tractors TLX00001-UP (MACHINE) POWERED BY 3046 Engine(SEBP3826 - 54) - Documentation

FMI 05 Voltage below normal or shorted low.

FMI 06 Failure mode not identifiable.


CID 1705 Proportional Solenoid Valve (Forward Right Drive Pump)

FMI 03 Voltage above normal or shorted high.

FMI 05 Voltage below normal or shorted low.

FMI 06 Failure mode not identifiable.

CID 1706 Proportional Solenoid Valve (Reverse Right Drive Pump)


FMI 03 Voltage above normal or shorted high.

FMI 05 Voltage below normal or shorted low.

FMI 06 Failure mode not identifiable.

CID 1707 Proportional Solenoid Valve (Left Drive Motor)


FMI 03 Voltage above normal or shorted high.

FMI 05 Voltage below normal or shorted low.

FMI 06 Failure mode not identifiable.

CID 1708 Proportional Solenoid Valve (Right Drive Pump)


FMI 03 Voltage above normal or shorted high.

FMI 06 Failure mode not identifiable.

FMI 05 Voltage below normal or shorted low.

CID 1960 ECM Cannot Communicate With the Electronic Key Reader
FMI 09 Abnormal Update.
(1) For the Machine ECM, the MID is 079. This table pertains only to diagnostic codes with a MID of 079.

Copyright 1993 - 2019 Caterpillar Inc. Wed Sep 18 2019 11:22:15 GMT-0500 (hora de verano central)
All Rights Reserved.
p230tav
Private Network For SIS Licensees.

https://sis.cat.com/sisweb/sisweb/techdoc/techdoc_print_page.jsp?returnurl=/sisweb/sisweb/mediasearch/mediaheaderinfoframeset.jsp&calledpage=/… 4/4