𝑑
𝑡𝑛𝑣 = 𝑡𝑧𝑎𝑠 𝑧𝑎 𝑝𝑑 = 0,71 𝑀𝑃𝑎 0.71
𝑑
𝑡𝑛𝑣 = 165,55 °𝐶 165.55
𝑑
𝑖𝑛𝑣 = 699,3 𝑘𝐽Τ𝑘𝑔 699.30
Odabrana temperatura napojne vode i ostali parametri iz ZVP1 kod normalnog režima rada:
𝑣 237.00
𝑡𝑛𝑣 = 𝑡𝑍𝑉𝑃1 = 237 °𝐶
𝑣 14.70
𝑝𝑍𝑉𝑃1 = 14,7 𝑀𝑃𝑎
𝑣 15.70
𝑝𝑍𝑉𝑃2 = 15,7 𝑀𝑃𝑎
𝑣
𝑝𝑛𝑝 = 16,7 𝑀𝑃𝑎 16.70
𝑑 𝑣
𝑣
𝑡𝑛𝑣 + 𝑡𝑍𝑉𝑃1 201.28
𝑡𝑍𝑉𝑃2 = = 201,28 °𝐶
2
𝑣 239.00
𝑡𝑧𝑎𝑠,1 = 𝑡𝑍𝑉𝑃1 + Θ = 237 + 2 = 239 °𝐶
𝑣 203.28
𝑡𝑧𝑎𝑠,2 = 𝑡𝑍𝑉𝑃2 + Θ = 201,28 + 2 = 203,28 °𝐶
TAČKA 0-0'
Parametri pare ispred turbine:
𝑝0 = 13,20 𝑀𝑃𝑎 13.20
𝑡0 = 530 °𝐶 530.00
Zbog pada pritiska u regulacionom ventilu od 5%, parametri na samom ulazu u stupanj su:
TAČKA 0'-1
𝑖 −𝑖
𝜂𝑜𝑖1 = 𝑖 0−𝑖 1 ⇒ 𝑖1 = 𝑖0 − 𝜂𝑜𝑖1 𝑖0 − 𝑖1𝑡 ⇒ 𝑖1 = 3075,89 𝑘𝐽Τ𝑘𝑔 3075.89
0 1𝑡
TAČKA 1-2
𝑖 −𝑖
𝜂𝑜𝑖2 = 𝑖 1−𝑖 2 ⇒ 𝑖2 = 𝑖1 − 𝜂𝑜𝑖2 𝑖1 − 𝑖2𝑡 ⇒ 𝑖2 = 2934,9 𝑘𝐽Τ𝑘𝑔 2934.81
1 2𝑡
TAČKA 2-3
𝑖 −𝑖
𝜂𝑜𝑖3 = 𝑖 2−𝑖 3 ⇒ 𝑖3 = 𝑖2 − 𝜂𝑜𝑖3 𝑖2 − 𝑖3𝑡 ⇒ 𝑖3 = 2783,77 𝑘𝐽Τ𝑘𝑔 2783.77
2 3𝑡
𝑑
𝑖𝑛𝑝 = 𝑖𝑛𝑣 + 𝜏𝑛𝑝 = 699,3 + 26,9 = 726,2 𝑘𝐽Τ𝑘𝑔 726.20
Pritisak napojne vode iza ZVP2 = 15,7 MPa, pa na osnovu temperature 201,28 °C slijedi da je
entalpija napojne vode iza ZVP2:
𝑣
𝑖𝑍𝑉𝑃2 = 858,2 𝑘𝐽Τ𝑘𝑔 858.20
Pritisak napojne vode iza ZVP1 = 14,7 MPa, pa na osnovu temperature 237 °C slijedi da je
entalpija napojne vode iza ZVP1:
𝑣 1023.40
𝑖𝑍𝑉𝑃1 = 1023,4 𝑘𝐽Τ𝑘𝑔
𝑣 𝑣
𝜏𝑍𝑉𝑃1 = 𝑖𝑍𝑉𝑃1 − 𝑖𝑍𝑉𝑃2 = 1023,4 − 858,2 = 165,20 𝑘𝐽Τ𝑘𝑔 165.20
𝑣
𝜏𝑍𝑉𝑃2 = 𝑖𝑍𝑉𝑃2 − 𝑖𝑛𝑝 = 858,2 − 726,2 = 132,00 𝑘𝐽Τ𝑘𝑔 132.00
𝑑 𝑣
𝜏𝐷𝑁𝑉 = 𝑖𝑛𝑣 − 𝑖𝑍𝑁𝑃4
𝑣 𝑑
𝑖𝑍𝑁𝑃4 = 𝑖𝑛𝑣 − 𝜏𝐷𝑁𝑉 = 699,30 − 90 = 609,30 𝑘𝐽Τ𝑘𝑔 609.30
Slika 3.
𝑣 𝑑
𝑖𝑍𝑁𝑃4 = 𝑖𝑛𝑣 − 𝜏𝐷𝑁𝑉 = 699,30 − 195,5 = 503,8 𝑘𝐽Τ𝑘𝑔 503.80
𝑣
𝑖𝐻𝑍𝑃 = 210,5 𝑘𝐽Τ𝑘𝑔 210.50
𝑣
𝑝𝐻𝑍𝑃 = 1,4 𝑀𝑃𝑎 1.40
𝑣
𝑡𝐻𝑍𝑃 = 50 °𝐶 50.00
𝑣 𝑣
𝑖𝑍𝑁𝑃5 = 𝑖𝑍𝑁𝑃4 − 𝜏4 = 354,4 𝑘𝐽Τ𝑘𝑔 354.40
Pritisak iza pumpe za kondenzat je 1,6 Mpa, iza hladnjaka zaptivnih para 1,4 Mpa, a iza ZNP:
𝑣
𝑝𝑍𝑁𝑃4 = 1,0 𝑀𝑃𝑎
𝑣
𝑝𝑍𝑁𝑃5 = 1,2 𝑀𝑃𝑎
𝑣 𝑣
𝑖𝑍𝑁𝑃4 = 503,8 𝑘𝐽Τ𝑘𝑔 𝑡𝑍𝑁𝑃4 = 120 °𝐶
𝑣 𝑣
𝑖𝑍𝑁𝑃5 = 354,4 𝑘𝐽Τ𝑘𝑔 , 𝑡𝑍𝑁𝑃5 = 84,4 °𝐶
𝑣 𝑣
𝑖𝐻𝑍𝑃 = 210,5 𝑘𝐽Τ𝑘𝑔 , 𝑡𝐻𝑍𝑃 = 50 °𝐶
Temperature zasićenja:
𝑣
𝑡𝑧𝑎𝑠,4 = 𝑡𝑍𝑁𝑃4 + Θ = 123°𝐶 123.00
𝑣
𝑡𝑧𝑎𝑠,5 = 𝑡𝑍𝑁𝑃4 + Θ = 87,3°𝐶 87.30
𝑧𝑎𝑠
𝑝𝑍𝑁𝑃4 = 0,2182 𝑀𝑃𝑎 0.2182
𝑧𝑎𝑠
𝑝𝑍𝑁𝑃5 = 0,0632 𝑀𝑃𝑎 0.0632
𝑧𝑎𝑠 516.40
𝑖𝑍𝑁𝑃4 = 516,4 𝑘𝐽Τ𝑘𝑔
𝑧𝑎𝑠 366.20
𝑖𝑍𝑁𝑃5 = 366,2 𝑘𝐽Τ𝑘𝑔
𝑖 −𝑖
𝜂𝑜𝑖4 = 𝑖 3−𝑖 4 ⇒ 𝑖4 = 𝑖3 − 𝜂𝑜𝑖4 𝑖3 − 𝑖4𝑡 ⇒ 𝑖4 = 2723,34 𝑘𝐽Τ𝑘𝑔 2723.34
3 4𝑡
𝑖4 −𝑖5
𝜂𝑜𝑖5 = ⇒ 𝑖5 = 𝑖4 − 𝜂𝑜𝑖5 𝑖4 − 𝑖5𝑡 ⇒ 𝑖5 = 2700,15 𝑘𝐽Τ𝑘𝑔 2700.15
𝑖4 −𝑖5𝑡
𝑖 −𝑖
𝜂𝑜𝑖𝑘 = 𝑖 5−𝑖 𝑘 ⇒ 𝑖𝑘 = 𝑖5 − 𝜂𝑜𝑖𝑘 𝑖5 − 𝑖𝑘𝑡 ⇒ 𝑖𝑘 = 2531,28 𝑘𝐽Τ𝑘𝑔 2531.28
5 𝑘𝑡
𝑣 𝑣
𝜏𝑍𝑁𝑃4 = 𝑖𝑍𝑁𝑃4 − 𝑖𝑍𝑉𝑃5 = 503,8 − 354,4 = 149,4 𝑘𝐽Τ𝑘𝑔 149.40
𝑣 𝑣
𝜏𝑍𝑁𝑃5 = 𝑖𝑍𝑁𝑃4 − 𝑖𝐻𝑍𝑃 = 354,4 − 210,5 𝑘𝐽Τ𝑘𝑔 = 143,9 𝑘𝐽/𝑘𝑔 143.90
Pošto je pad pritiska od oduzimanja do vršnog i osnovnog zagrijača 5%, pritisci u zagrijačima
su:
𝑖4 = 2723,34 𝑘𝐽Τ𝑘𝑔 𝑝4 = 0,24 𝑀𝑃𝑎 ⇒ za VZ 𝑝4′ = 0,228 𝑀𝑃𝑎
Temperatura pare,
𝑡5 114.77 𝑡4 130.18
°C
Entalpija pare, kJ/kg 𝑖5 2700.15 𝑖4 2723.34
Predata toplota,
𝑞𝑂𝑍 2239.7 𝑞𝑉𝑍 2200.94
kJ/kg
Kondenzat grejne
Pritisak u zagrijaču,
𝑝𝑧𝑎𝑠,𝑂𝑍 0.1425 𝑝𝑧𝑎𝑠,𝑉𝑍 0.228
MPa
pare
Temperatura
𝑡𝑧𝑎𝑠,𝑂𝑍 109.84 𝑡𝑧𝑎𝑠,𝑉𝑍 124.43
zasićenja, °C
Entalpija
𝑖5′ 460.8 𝑖4′ 522.4
kondenzata, kJ/kg
MPa
Temperatura vode na 𝑣 𝑣
𝑡𝑂𝑍 85 𝑡𝑉𝑍 120
izlazu u zagrijač, °C
Entalpija vode na
izlazu u zagrijač, 𝑣 356.6 𝑣 503.7
𝑖𝑂𝑍 𝑖𝑉𝑍
kJ/kg
Nedogrijanost vode
Θ𝑂𝑍 2.6 Θ𝑉𝑍 3
u zagrijaču, °C
Nedogrijanost vode
𝜈𝑂𝑍 𝜈𝑉𝑍
u zagrijaču, kJ/kg
Zagrijavanje vode u
𝜏𝑂𝑍 83.9 𝜏𝑉𝑍 147.1
zagrijaču, kJ/kg
Koeficijent
iskorištenja 𝜂𝑂𝑍 0.995 𝜂𝑉𝑍 0.995
zagrijača
𝑄𝑡𝑝 ∙ 103
𝐺𝑚𝑣 = 𝑣 𝑢𝑙
= 1000,67 𝑘𝑔/𝑠 1000.67
(𝑖𝑉𝑍 − 𝑖𝑂𝑍 )𝜂𝑡𝑝
𝐺𝑚𝑣 ∙ 𝜏𝑉𝑍
𝐷𝑉𝑍 = = 67,22 𝑘𝑔/𝑠 67.22
𝑞𝑉𝑍 ∙ 𝜂𝑉𝑍
Gdje su:
𝑁𝑒 160 ∙ 103
𝐷𝑘𝑢 = = = 185.88 𝑘𝑔/𝑠 185.88
𝐻𝑖 ∙ 𝜂𝑚 ∙ 𝜂𝑔 882,72 ∙ 0,99 ∙ 0,985
𝑖5 − 𝑖𝑘 2700,15 − 2531,28
𝑦𝑜𝑧 = = = 0,19131 0.19131
𝐻𝑖 882,72
𝑖4 − 𝑖𝑘 2723.34 − 2531,28
𝑦𝑣𝑧 = = = 0,21758 0.21758
𝐻𝑖 882,72
𝑖3 − 𝑖 𝑘 2783,77 − 2531,28
𝑦𝑝𝑜 = = = 0,28604 0.28604
𝐻𝑖 882,72
𝛽𝑟 = 1,15 1.15
𝐷0 = 𝛽𝑟 𝐷𝑘𝑢 + 𝑦𝑝𝑜 ∙ 𝐷𝑝𝑜 +𝑦𝑜𝑧 ∙ 𝐷𝑜𝑧 + 𝑦𝑣𝑧 ∙ 𝐷𝑣𝑧 =240,29 kg/s 240.29
𝐷𝑣𝑧
𝛼𝑉𝑍 = = 0,27975 0.27975
𝐷0
𝐷𝑜𝑧
𝛼𝑂𝑍 = = 0,14907 0.14907
𝐷0
𝑣
𝑖𝑑.1 = 𝑖𝑍𝑉𝑃2 + 𝜈ℎ𝑑.1 = 858,2 + 40 = 898,2 𝑘𝐽/𝑘𝑔
𝛼𝑛𝑣 ∙ 𝜏𝑍𝑉𝑃2 ∙ 𝑘𝑍𝑉𝑃2 = 𝛼𝑍𝑉𝑃2 ∙ 𝑞𝑍𝑉𝑃2 + 𝑞ℎ𝑑.2 + 𝛼𝑍𝑉𝑃1 ∙ 𝑖𝑑.1 + 𝑖𝑑.2 + 𝛼𝑧𝑝2 ∙ 𝑞𝑧𝑝2
𝑣
𝑖𝑑.2 = 𝑖𝑛𝑝 + 𝜈ℎ𝑑.2 = 726,6 + 40 = 766,6 𝑘𝐽/𝑘𝑔
kJ
𝑞𝑧𝑝2 = 2460 − usvojeno
kg
𝛼𝑛𝑣 ∙ 𝜏𝑍𝑉𝑃2 ∙ 𝑘𝑍𝑉𝑃2 − 𝛼𝑍𝑉𝑃1 ∙ 𝑖𝑑.1 + 𝑖𝑑.2 + 𝛼𝑧𝑝2 ∙ 𝑞𝑧𝑝2
𝛼𝑍𝑉𝑃2 = = 0,06257 0.06257
𝑞𝑍𝑉𝑃2 + 𝑞ℎ𝑑.2
𝑣 𝑣
𝛼𝑍𝑉𝑃1 ∙ 𝑞ℎ𝑑.1 = 𝛼𝑛𝑣 ∙ 𝑖ℎ𝑑.1 − 𝑖𝑍𝑉𝑃2 ∙𝑘
𝑣 𝛼𝑍𝑉𝑃1 ∙ 𝑞ℎ𝑑.1 𝑣
𝑖ℎ𝑑.1 = + 𝑖𝑍𝑉𝑃2 = 869,35 𝑘𝐽/𝑘𝑔 869.35
𝛼𝑛𝑣 ∙ 𝑘
𝑣 𝑣 11.15
𝜏ℎ𝑑.1 = 𝑖ℎ𝑑.1 − 𝑖𝑍𝑉𝑃2 = 11,15 𝑘𝐽/𝑘𝑔
𝑣 200.00
𝑝ℎ𝑑.1 = 15,5 𝑀𝑃𝑎 ⇒ 𝑡ℎ𝑑.1 = 200 °𝐶
𝑜
𝑡𝑧1 = 𝑡1′ + Θℎ𝑝 = 241,76 + 10 = 261,76 °𝐶 261.76
Uzimajući u obzir gubitak pritiska pare u HP1, parametri pare na izlazu su:
𝑜 𝑜 2857.00
𝑝𝑧1 = 3,705 𝑀𝑃𝑎 ⇒ 𝑖𝑧1 = 2857,0 𝑘𝐽/𝑘𝑔
𝑜 𝑣
𝛼𝑍𝑉𝑃1 𝑖𝑧.1 − 𝑖1′ = 𝛼𝑛𝑣 ∙ 𝑖𝑧.1
𝑣
− 𝑖ℎ𝑑.1 ∙𝑘
𝑜
𝑣
𝛼𝑍𝑉𝑃1 𝑖𝑧.1 − 𝑖1′ 𝑣
𝑖𝑧.1 = + 𝑖ℎ𝑑.1 = 1005,92 𝑘𝐽/𝑘𝑔 1005.92
𝛼𝑛𝑣 ∙ 𝑘
𝑣 𝑣
𝑝𝑧1 = 15,1 𝑀𝑃𝑎 ⇒ 𝑡𝑧1 = 235°𝐶 235.00
𝑣
𝛼𝑍𝑉𝑃1 ∙ 𝑖𝑑.1 − 𝑖𝑑.2 +𝛼𝑍𝑉𝑃2 ∙ 𝑞ℎ𝑑.2 = 𝛼𝑛𝑣 ∙ 𝑖ℎ𝑑.2 − 𝑖𝑛𝑝 ∙ 𝑘
𝑣 𝑣
𝑝ℎ𝑑.2 = 16,4 𝑀𝑃𝑎 ⇒ 𝑡ℎ𝑑.2 = 170 °𝐶
𝑣
𝛼𝑘𝑑 ∙ 𝑖𝑍𝑁𝑃4 + 𝛼𝑑 ∙ 𝑖3 + 𝛼𝑙 ∙ 𝑖𝑑′ + 𝛼𝑟𝑠𝑣 ∙ 𝑖𝑟𝑠𝑣 + 𝛼𝑍𝑉𝑃1 + 𝛼𝑍𝑉𝑃2 + 𝛼𝑧𝑝2 ∙ 𝑖𝑑2
= [ 𝛼𝑧𝑑 + 𝛼𝑒 ∙ 𝑖𝑑′′ + 𝛼𝑔𝑢𝑏.𝑘 ∙ 𝑖𝑑′ + 𝛼𝑛𝑣 ∙ 𝑖𝑑′ ] ∙ 𝑘𝑑
𝛼𝑑 = 0,08521 0.08521
⬚ 𝑣 ⬚
𝛼𝑍𝑁𝑃4 ∙ 𝑖4⬚ + (𝛼𝑍𝑁𝑃4 + 𝛼𝑍𝑁𝑃5 ) ∙ 𝑖𝑑5 ′
+ (𝛼𝑉𝑍 +𝛼𝑂𝑍 ) ∙ 𝑖𝑂𝑍 + 𝛼𝑘5 ∙ 𝑖𝑍𝑁𝑃5 + 𝛼𝑡.𝑝𝑘 ∙ 𝑖𝑡.𝑝𝑘
𝑣 ⬚
= [ 𝛼𝑘𝑑 ∙ 𝑖𝑍𝑁𝑃4 ) + (𝛼𝑍𝑁4 ∙ 𝑖𝑑4 ] ∙ 𝑘𝑍𝑁𝑃5
𝐷𝑜𝑑 20
𝛼𝑡.𝑝𝑘 = = = 0,023120 0.023120
𝐷0 3,6 ∙ 240,29
⬚ ⬚
𝑖𝑡.𝑝𝑘 = 𝑐𝑝 ∙ 𝑡𝑡.𝑝𝑘 = 4,19 ∙ 85 = 356,2 𝑘𝐽/𝑘𝑔 356.20
𝑣
𝑖𝑑4 = 𝑖𝑍𝑁𝑃5 + 𝜈 = 354,4 + 40 = 394,4 𝑘𝐽/𝑘𝑔
𝑣
𝑖𝑑5 = 𝑖𝐻𝑍 + 𝜈 = 210,5 + 40 = 250,5 𝑘𝐽/𝑘𝑔
𝑣 𝑣
𝛼𝑍𝑁𝑃5 ∙ 𝑖5 + 𝛼𝑍𝑁𝑃4 ∙ 𝑖𝑑4 + 𝛼𝑘5 ∙ 𝑖𝐻𝑍𝑃 = [𝛼𝑘5 ∙ 𝑖𝑍𝑁𝑃5 + (𝛼𝑍𝑁𝑃4 + 𝛼𝑍𝑁𝑃5 ) ∙ 𝑖𝑑5 ] ∙ 𝑘𝑍𝑁𝑃5
𝛼𝑍𝑁𝑃4 = 0,08671
𝛼𝑍𝑁𝑃5 = 0,00988
𝛼𝑘5 = 0,25507
Nakon uvrštavanja:
𝛼𝑟𝑒𝑐 = 0,27241
Kratnost hlađenja:
𝛼𝑟𝑒𝑐 + 𝛼𝑘5
𝑚𝑟𝑒𝑐 = = 2,068
𝛼𝑘5
Jednačina toplotnog bilansa hladnjaka zaptivnih para (HZP):
𝜏𝐻𝑍 𝜏𝐻𝑍
𝑞𝐻𝑍 ∙ 𝛼𝐻𝑍 = (𝛼𝑘5 +𝛼𝑟𝑒𝑐 ) ∙ = 0,016 ∙ 2200 = (0,25507 + 0,27241) ∙
𝜂𝐻𝑍 0,995
𝜏𝐻𝑍 = 66,4 𝑘𝐽/𝑘𝑔
𝑣 𝑣 𝑣 𝑣
𝜏𝐻𝑍 = 𝑖𝐻𝑍 − 𝑖𝐻𝐸 ⇒ 𝑖𝐻𝐸 = 𝑖𝐻𝑍 − 𝜏𝐻𝑍 = 144,1 𝑘𝐽/𝑘𝑔
𝑣
𝜏𝑒 = 𝑖𝐻𝐸 − 𝑖𝑘′ = 99,4 𝑘𝐽/𝑘𝑔
𝛼1 = 𝛼𝑍𝑉𝑃1 = 0,07662
𝛼2 = 𝛼𝑍𝑉𝑃2 = 0,06257
𝛼𝑖 = 0,77293
𝑖=1
𝛼𝑟𝑠𝑣 = 0,005
5
𝑝
𝛼𝑘 = 𝛼0 − 𝛼𝑟𝑠𝑣 − 𝛼𝑖 = 0,22207
𝑖=1
𝑝
𝛼𝑘 − 𝛼𝑘𝑣
∆= 𝑝 ∙ 100 = 3,81 %
𝛼𝑘
𝐷0 = 240,29 𝑘𝑔/𝑠
𝐷1 = 𝛼1 ∙ 𝐷0 = 18,41 𝑘𝑔/𝑠
𝐷2 = 𝛼2 ∙ 𝐷0 = 15,03 𝑘𝑔/𝑠
𝐷3 = 𝛼3 ∙ 𝐷0 = 26,03 𝑘𝑔/𝑠
𝐷4 = 𝛼4 ∙ 𝐷0 = 88,06 𝑘𝑔/𝑠
𝐷5 = 𝛼5 ∙ 𝐷0 = 38,19 𝑘𝑔/𝑠
𝑝
𝐷𝑘 = 𝛼𝑘𝑝 ∙ 𝐷0 = 53,36 𝑘𝑔/𝑠
Greška:
160,92 − 160
∆= ∙ 100 = 0,57%
160,92
𝑒
1
𝑞𝑡𝑝 = 𝑒 ∙ 3600 = 5921,05 𝑘𝐽/𝑘𝑊ℎ
𝜂𝑡𝑝
𝑄𝑡𝑝
𝜂𝑐 = = 0,989
𝑄𝑔𝑝
𝜂𝑒𝑇𝐸−𝑇𝑂 = 𝜂𝑡𝑝
𝑒
∙ 𝜂𝑐 ∙ 𝜂𝑔𝑝 = 0,535
𝑒
1
𝑞𝑇𝐸−𝑇𝑃 = ∙ 3600 = 7157,06 𝑘𝐽/𝑘𝑊ℎ
𝜂 𝑒𝑇𝐸−𝑇𝑂
123
𝑏𝑢𝑒 = = 229,91 𝑔/𝑘𝑊ℎ
𝜂𝑒𝑇𝐸−𝑇𝑂
5.3.6. Specifična potrošnja uslovnog goriva za proizvodnju jedinice toplote vanjskog
potrošača
𝑝 123
𝑏𝑢 = = 140,41 𝑔/𝑘𝑊ℎ
𝜂 𝑡𝑇𝐸−𝑇𝑂