Etap Excel
Etap Excel
Z1 3 1 1
Description POWER_REQ From Bus To Bus Positive
ID ID R
Y 280-EE-0700A 280-EE-0503A 1
Positive Positive Zero Zero Zero Comment
X Y R X Y
10 0 1 10
Equipment 1-PHASE Rated Rated Service Type
ID Y/N Amps kV 1 = In Service
X1 N 100 11 0
Description POWER_REQ From Bus To Bus Positive
ID ID Z (ohms)
Y 280-EE-0700A 280-EE-0501A 10
Positive Zero Zero Tolerance Comment
X/R Z (ohms) X/R in %
19.5 10 19.5
Equipment Length Length Tolerance Service Type
ID Unit in % 1 = In Service
Line1 100 0 1
Description POWER_REQ From Bus To Bus Temperature
ID ID Base T1 (°C)
Y 280-EE-0500A 280-EE-0502A 75
Temperature Temperature Temperature Positive Positive Positive
Base T2 (°C) Minimum (°C) Maximum (°C) R1 R2 X
75 75 75 0.8 0.8 5
Impedance per Conductor
Positive Negative Negative Negative Negative Zero
Y R1 R2 X Y R1
0
Equipment No per Service Type Description POWER_REQ From Bus
ID Phase 1 = In Service ID
75 20 0 0 55 95
Cable Impedance per Conductor
Positive Positive Positive Zero Zero Zero
R X Y R X Y
A B C D E F G H I J K
1
2
3 Equipment POWER_REQ Service Type Bus ID Data Type Priority Description Rating kV %EFF Comment
4 ID 1 = In Service kW
5 VFD1 Y 1 280-EE-0503A 0 0 POWER FACTOR CORRECTIONCAPACITOR 250 11 90
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z AA AB AC AD AE AF AG AH AI AJ AK AL AM AN AO AP AQ AR AS AT AU AV AW AX AY AZ BA
1
2 MOV Starting Period No Load Period Travelling Period Seating_Unseating Equipment Cable Library Data
Equipment QUANTITY POWER_REQ Bus ID Data Type Priority Initial Status Service Type Description Motor Motor Rated 1-PHASE Phase Closing Opening Throttling Spare %PF %EFF FLA Start %FLA LR %PF Start Time NL %FLA NL%PF NL Time TP %FLA TP %PF TP Time Seat %FLA Seat %PF Seat Time Unit System Frequency Conductor Type Installation Cable % Class Cable Source Insulation #/Cable Cable Library Library Base Cable ID No per Cable Cable Length Cable Temperature Cable Comment
3 Torque Temperatur
e
ID 1 = In Service kV kW ft-lb Y/N Connection DF DF DF DF sec sec sec sec English or Metric 60 Hz or 50 Hz Al or Cu Mag/Non- Voltage (kV) 100 or 133% 1/C or 3/C Size Unit Length Length Unit Temperature (°C) Phase Length Unit Minimum (°C) Maximum
4 Mag/Overhead (°C)
5 MOV1 3 Y 280-EE-0504A 0 0 1 1 11 50 N 3 English 60 Cu Non-Mag. 15 100 ICEA Rubber 3/C 8 1000 0 75 Cable2 5 55 95
File: 441849856.xls
Printed: 20:28:10 10/13/2019 Sheet 21 of 35
Tab: MOV
BORGER VACUUM / COKER ELECTRICAL LOAD LIST
NON-MOTOR LOADS
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z AA AB AC AD AE AF AG AH AI AJ AK AL AM AN AO
1
2 Equipment Cable Library Data
Equipment QUANTITY POWER_REQ Plant Area Bus ID Data Type VFD Y/N Priority RUN_INT_SP Service Type Description Load Load % PF 1-PHASE Phase Cont Interm Spare Delta-Wye-Grd Operating Unit System Frequency Conductor Type Installation Cable % Class Cable Source Insulation #/Cable Cable Library Library Base Cable ID No per Cable Cable Length Cable Temperature Cable Temperature Comment
3
ID 1 = In Service Voltage kVA Y/N Connection DF DF DF Connection Load (kVA) English or Metric 60 Hz or 50 Hz Al or Cu Mag/Non- Voltage (kV) 100 or 133% 1/C or 3/C Size Unit Length Length Unit Temperature (°C) Phase Length Unit Minimum (°C) Maximum (°C)
4 Mag/Overhead
5 280-EE-0750AKS 2 Y 280-EE-0700A 2 N 0 SP 1 POWER FACTOR CORRECTIONCAPACITOR 11000 2000 90 N 100 30 10 2 0 English 60 Cu Mag. 15 100 ICEA Rubber 3/C 2 1000 0 75 Cable3 5 55 95
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z AA AB AC AD AE AF AG AH AI AJ AK AL AM AN
1
2 Equipment Cable Library Data
Equipment QUANTITY POWER_REQ Plant Area Bus ID Data Type Priority RUN_INT_SP Service Type Description Heater Heater % PF 1-PHASE Phase Cont Interm Spare Delta-Wye-Grd Operating Unit System Frequency Conductor Type Installation Cable % Class Cable Source Insulation #/Cable Cable Library Library Base Cable ID No per Cable Cable Length Cable Temperature Cable Comment
3 Temperature
ID 1 = In Service Voltage kW Y/N Connection DF DF DF Connection Load (kW) English or Metric 60 Hz or 50 Hz Al or Cu Mag/Non- Voltage (kV) 100 or 133% 1/C or 3/C Size Unit Length Length Unit Temperature (°C) Phase Length Unit Minimum (°C) Maximum (°C)
4 Mag/Overhead
5 S-110-TRACE 2 Y 4A1 280-EE-0504A 1 0 INT 1 Caustic Line Heat Tracing 11,000 15.00 100 N 3 100.00 50.00 0.00 1 15.00 English 60 Cu Mag. 15 100 ICEA Rubber 3/C 2 1000 0 75 Cable4 1 450 0 55 95
ID 1 = In Service
1
Primary Bus ID Secondary Bus ID Tertiary Bus ID Temp Rise Transformer Primary Transformer Primary
Rating Rating UOM
0
Primary Primary Voltage UOM Secondary Secondary Tertiary Tertiary Secondary
Voltage Voltage Voltage UOM Voltage Voltage UOM Rating
kV kV kV
Secondary Tertiary Tertiary Rating UOM Pri-Sec Pri-Sec Impedance UOM Pri-Ter Impedance
Rating UOM Rating Impedance
Pri-Ter Impedance Sec-Ter Sec-Ter Impedance Cooling Code Pri-Sec X/R Pri-Ter X/R Sec-Ter X/R
UOM Impedance UOM
Transformer Basic Impulse Level
Max Rating
Equipment QUANTITY Service Type Description POWER_REQ
ID 1 = In Service
280-ET-0511A 1 1 33/11.5KV SUB 5 Y
280-ET-0700A 1 0 33/11.5KV SUB 7 Y
Primary Bus ID Secondary Bus ID Temp Rise Transformer Primary Rating Transformer Primary Primary Voltage
Rating UOM
kV 11 kV 10 Ohm
kV 11 kV 10 Ohm
Basic Impulse Level Cooling Code K Factor Max Transformer Rating X/R Ratio
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z AA AB AC AD AE AF AG AH AI AJ AK AL AM AN AO AP AQ AR AS AT AU AV AW AX AY AZ BA BB BC BD BE BF BG BH
1
2 Equipment Cable Library Data
Equipment QUANTITY POWER_REQ VFD Y/N Plant Area Bus ID Data Type Priority RUN_INT_SP Service Type Description Motor Motor Brake 1-PHASE Phase Cont Interm Spare %PF %PF %PF %EFF %EFF %EFF % Locked % Starting Starting Delta-Wye Grounding Grd Device Rated % Slip Service Stall Time Stall Time Unit System Frequency Conductor Type Installation Cable % Class Cable Source Insulation #/Cable Cable Library Library Base Cable ID No per Cable Cable Length Cable Temperature Cable Temperature Comment
3
ID 1 = In Service Voltage kW kW Y/N Connection DF DF DF 100% 75% 50% 100% 75% 50% Rotor Current PF Device Connection Type Amp Rating RPM Factor Hot Start Cold Start English or Metric 60 Hz or 50 Hz Al or Cu Mag/Non- Voltage (kV) 100 or 133% 1/C or 3/C Size Unit Length Length Unit Temperature (°C) Phase Length Unit Minimum (°C) Maximum (°C)
4 Mag/Overhead
5 141-CM-101A 1 Y N 280-EE-0501A 0 0 S 1 BOOSTER COMPRESSORAFTERCO 11000 37 26.3 N 100 30 10 86 91 20 0 0 1 1800 2 1 English 60 Cu Mag. 15 100 ICEA Rubber 3/C 8 1000 0 75 Cable5 8 0 55 90 INFO FROM HEAT EXCHANGER DATA SHEET
6 262-PM-201A 1 Y N 280-EE-0700A 1 0 I 1 CONDENSATE COLLECTION PUM 11000 22 15 N 100 30 10 88 90 20 0 0 1 1800 1 1 ESTIMATED ABSORBED LOAD
7 262-PM-201B 1 Y N 280-EE-0501A 2 0 C 1 CONDENSATE COLLECTION PUM 11000 22 15 N 100 30 10 88 90 20 0 0 1 1800 1 1 ESTIMATED ABSORBED LOAD
8 262-PM-201C 2 Y N 280-EE-0501A 3 0 C 1 CONDENSATE COLLECTION PUM 11000 22 15 N 100 30 10 88 90 20 0 0 1 3600 1 1 ESTIMATED ABSORBED LOAD
A B C D E F G H I J K L M N O P
1 ETAP 6.0.0
2
3 Equipment POWER_REQ Bus Initial Service Type Description Min % DF Max % DF ANSI or IEC Bus Type Cont Bracing Bracing Bracing Bracing Comment
ID Voltage % Voltage 1 = In Service Rating (A) Symm RMS (kA) ASymm RMS (kA) Crest (kA) Peak kA
4 (IEC)
5 280-EE-0500A YES 33000 100 1 SUB 5 33KV BUS A 80 100 0 0 2500 30 32 35
6 280-EE-0501A YES 11000 100 1 SUB 5 11KV BUS A 80 100 0 2 2500
7 280-EE-0700A YES 11000 100 1 SUB 7 11KV BUS A 80 100 0 3 1600
8 280-EE-0502A YES 33000 100 1 SUB 52 11KV BUS A 80 100 0 7 1600 30 32 35
9 280-EE-0503A YES 11000 100 1 SUB 53 11KV BUS A 80 100 1 1 1600 36 40
10 280-EE-0504A YES 11000 100 1 SUB 53 11KV BUS A 80 100 0 2 1600