FOOTING SCHEDULE

FOOTING COLUMN ID FOOTING TYPE FOOTING DIMENSION DEPTH REINFORCE


ID R.C.C SIZE P.C.C. SIZE MENT
L B L B D d DETAILS
F1 C1 TRAPEZOIDAL 6’ 7’ 6’ - 6” 7’ – 6” 30” 12” 12MM @
7'
125 MM
4” THICK 12"
C1 C/C BOTH
P.C.C. SIDE

6'
21"

F2 C2 TRAPEZOIDAL 3’6” 5’ 4’ – 0” 5’ – 6” 21” 9” 10MM @


5'
125MM
18" C/C BOTH
3'-6"
9"

SIDE
C2

COLUMN SCHEDULE
COLUMN ID COLUMN REINFORCEMENT DETAILS
DIMENSION
C1 12” x 21” STIRRUPS:
21"
REGULAR ZONE: 8# - 150MM C/C
CONFINED ZONE(CZ): 8# - 100MM C/C
12"

- 16 #
- 12 #

MAIN 8 – 16# + 6 – 12#


C2 9” x 18” 18" RING:
REGULAR ZONE: 8# - 150MM C/C
CONFINED ZONE(CZ): 8# - 100MM C/C
9"

- 12 #

MAIN 8 - 12#