SPREADSHEET OF
R.C. FOOTINGS FOR R.C. COLUMNS SUBJECTED TO VERTICAL LOAD
& MOMENTS BY WORKING STRESS METHOD AS PER IS:456-2000
Concrete Grade = M 3
Yield Strength of Steel, fy (N/mm2) = 4
Modular Ratio DL+LL case (Wind/Seismic in bracket), m = 10.98 (8.24)
SBC of soil (Gross) at depth H below G.L.under DL + LL = 140 kN/m2
-Do- above under DL + LL + Wind/Seismic = 190 kN/m2
Density of dry soil, γsoil =
3
18 kN/m
Density of wet soil, if any (Approx.=0.6* γsoil + 10) 20.8 kN/m3
Bottom Reinforcement:
Cover to Bar Dia.(mm)Actual Reinforcement along 'L' at btm. Reinforcement along 'B' at btm.
Footing btm bars along along Eff.'d' Ast reqd. Provide Ast Ast reqd. Provide Ast
2
Mk. (mm) L' B' (mm) (mm ) Nos. Dia.(mm) Spacing (mm2) (mm2) Nos. Dia.(mm Spacing (mm2)
F1 75 16 16 667 3600 23 16 180 4624 4500 29 16 175 5831
0 75 20 16 - 0 15 - - - 0 23 - - -
0 50 20 16 - 0 13 - - - 0 30 - - -
0 50 25 16 - 0 18 - - - 0 30 - - -
0 75 16 16 - 0 17 - - - 0 21 - - -
0 75 25 20 - 0 36 - - - 0 69 - - -
0 75 16 16 - 0 24 - - - 0 36 - - -
0 75 20 16 - 0 28 - - - 0 51 - - -
0 50 12 12 - 0 11 - - - 0 16 - - -
0 75 12 12 - 0 29 - - - 0 36 - - -
RCDesignCD
Company's Name: 0 Job No.: ABC/1001
0 Design by: UVW
Client: sanghi Date: 26-Sep-19
Project: tata yards Page No. F/103
Top Reinforcement:
Cover to Bar Dia.(mm)Actual Reinforcement along 'L' at top Reinforcement along 'B' at top
Footing top bars along along Eff.'d' Ast reqd. Ast Ast reqd. Ast
2
Provide 2 2
Provide
Mk. (mm) L' B' (mm) (mm ) (mm ) (mm ) (mm2)
F1 75 12 12 669 1440 15- 12dia.@280crs 1470 0 18- 12dia.@290crs 2036
0 50 12 12 - 0 - 0 0 - 0
0 50 12 12 - 0 - 0 0 - 0
0 75 0 0 - 0 - 0 0 - 0
0 75 12 12 - 0 - 0 0 - 0
0 75 12 12 - 0 - 0 0 - 0
0 75 12 12 - 0 - 0 0 - 0
0 75 12 12 - 0 - 0 0 - 0
0 50 12 12 - 0 - 0 0 - 0
0 75 12 12 - 0 - 0 0 - 0
Shears X-X
F1 0.173 0.055 480 0.18 0.259 -75 -0.03 0.253 597.4 0.590 0.800 -84 -0.08 0.800
0 - - - - - - - - - - - - - -
0 - - - - - - - - - - - - - -
0 - - - - - - - - - - - - - -
0 - - - - - - - - - - - - - -
0 - - - - - - - - - - - - - -
0 - - - - - - - - - - - - - -
0 - - - - - - - - - - - - - -
0 - - - - - - - - - - - - - -
0 - - - - - - - - - - - - - -
RCDesignCD
Company's Name: 0 Job No.: ABC/1001
0 Design by: UVW
Client: sanghi Date: 26-Sep-19
Project: tata yards Page No. F/104
Shears Y-Y
F1 0.179 0.062 187.1 0.057 0.262 0 0 0.253 253 0.173 0.8 0 0 0.800
0 - - - - - - - - - - - - - -
0 - - - - - - - - - - - - - -
0 - - - - - - - - - - - - - -
0 - - - - - - - - - - - - - -
0 - - - - - - - - - - - - - -
0 - - - - - - - - - - - - - -
0 - - - - - - - - - - - - - -
0 - - - - - - - - - - - - - -
0 - - - - - - - - - - - - - -
Factor of Safety
Footing against Over-turning Overall Status of
Mk about X-X about Y-Y Design
F1 1.960 N/A Section O.K.