Fault 1: The laser intensity decreases and the marking are not clear.
Solution:
Check if there is any change with the laser resonator; slightly adjust the lens of laser resonator to
make the light spot output much better;
The acousto-optic crystal shifts or the acousto-optic power supply is relatively too low; adjust the
position of acousto-optic crystal or increase the acousto-optic power working current; enter the
laser deviation center: adjust the laser;
If the current is adjusted to around 20A, the sensitive is still not strong enough: the aging krypton
lamp needs to be changed.
Solution:
Check all the power supply cables
The high-pressure krypton lamp is aging and needs to be changed.
Fault 3: when online, it has one long and three short alarms.