CE5510 Advanced Structural Concrete Design 

Solutions to Assignment 1 
 

Q1. 

z
50 z
B  400 cu fcd 
A  40 50 Cs4 
160  s4
200 s3 Cs3 
560  160  700  200 0.8h

s2 C 
160  200 Cs2 
s1 Cs1 
D  C  y  40 50 N.A. 

(a) N.A. is parallel to AB because the resultant tensile and compressive forces must lie on z‐
axis. 
 
(b) s1 = 0.0035(50/700) = 0.00025; s2 = 0.0035(250/700) = 0.00125; 
     s3 = 0.0035(450/700) = 0.00225 > yd = 0.00217 ; s2 > yd . 
    
    Cs1 = 3 x 490 x 0.00025 x 200 = 73.5 kN; Cs2 = 2 x 490 x 0.00125 x 200 = 245 kN; 
    Cs3 = 2 x 490 x (500/1.15) x 10‐3 = 426.1 kN; Cs2 = 639.1 kN . 
C = 500 x (0.8 x 560) x 0.567 x 30 x 10‐3 = 3810.2 kN  
 
N = 3810.2 + 73.5 + 245 + 426.1 + 639.1 = 5193.9 kN 
Ne = 3810.2(0.1 x 700) – 73.5(300) – 245(100) + 426.1(100) + 639.1(300) 
     = 454504 kNm 
e = 454504 / 5193.9 = 87.5 mm 
 
 (c) The internal forces have the same magnitude and location as shown above; hence the 
values of N and e remain the same.  
   
Q2. 

(a)  = 0.6(1‐30/250)=0.528  z 
     z = 0.9x1540=1386 mm  200 
     bw = 2x250 = 500 mm 
H13 
     VRd,max = 0.528x(30/1.5)x500x  
                    1386x10‐3/2 = 3659 kN  800 
     A = 1600x1600  
         = 2.56 x 106 mm2   y 
800 
     u = 6000 mm  H13‐
    tef = 2560/6 = 426.7 mm  150 
        > 200 mm (governs)  9H40 
        > 2 x 60 = 120 mm  600  1000  600 
   Ak = (1‐100/800)2x16002 
        = 1.96 x 106 mm2 
   uk = (1‐100/800)x6000  VEd/VRd,max + TEd/TRd,max  
       = 5250 mm       = 1200/3659 + 900/4140 
   TRd,max = 2x0.528x(30/1.5)x1.96 x        = 0.328 + 0.217 = 0.545 < 1    ok 
                  106 x200x10‐6/2  
               = 4140 kNm 
(b)  = 9000/(500x1540) = 0.0117; k = 1 +(200/1540)1/2 =  1.360 
     VRd,c = 0.12x1.360x(1.17x30)1/3x500x1540x10‐3 = 411 kN  
              > 0.035x1.3603/2x301/2x500x1540x10‐3 = 234 kN 
     fctd = 0.21x302/3/1.5 = 1.352 MPa 
     TRd,c = 2x1.96x106x1.352x200x10‐6 kN = 1060 kNm  
    VEd/VRd,c + TEd/TRd,c = 1200/411 + 900/1060 > 1 
     
    Design for shear & torsion: 
    Asw/s (per web) = [600x103/1386 + 900x106/(2x1.96x106)]/500/1.15  
      = 1524 mm2/m > 0.5Asw,min = 0.5x0.0830x500/(500/1.15) = 252 mm2/m 
     use H13 double‐legged links@150 mm spacing (1770 mm2/m) 
    Check: s < 0.75x1540 = 770 mm; 6000/8= 750 mm; 200 mm 
   Asl (shear) = 0.5x1200x103/(500/1.15) = 1380 mm2  
(to be provided in lower flange) 
   Asl (torsion) = 900x106x5250/(2x1.96x106x500/1.15) =2772 mm2 
    provide 24H13 (3186 mm2) with 6H13 (796 mm2) in lower flange. 
Asl to be provided in lower flange = 9000 (flexure) + 1380 (shear) + 796  
      (torsion) = 11176 mm2  provide 9H40 (11311 mm2) 
Reinforcement sketch  see above figure. 
 
 
 
 