11 In tankers, electrical equipment, cables and wiring shall not be installed in hazardous
locations unless it conforms with standards not inferior to those acceptable to the
Organization.* However, for locations not covered by such standards, electrical equipment,
cables and wiring which do not conform to the standards may be installed in hazardous
locations based on a risk assessment to the satisfaction of the Administration, to ensure that
an equivalent level of safety is assured.
Interpretation
Where the prescriptive requirements within SOLAS and related Codes (IBC, IGC) and the
standards published by the International Electrotechnical Commission, such as but not limited
to IEC 60092-502, are not aligned, the prescriptive requirements in SOLAS and Codes take
precedence and are to be applied. The differences revealed between the above mentioned
documents are listed in Annex 1.
Note:
ANNEX 1 - Summary of Discrepancies on the Hazardous Area Classification Issues among SOLAS/IBC/IGC and IEC 60092-502
SC
274 No. Title SOLAS IBC IGC IEC 60092-502:1999
(cont) 1 Hazardous area and Within 5m radius; SOLAS Within 4.5m radius; IEC
classification on open Reg. II-2/11.6.2.2. 60092-502, 4.2.2.7 and
deck from the cargo tank 4.2.3.1.
ventilation outlet for small Reference is made to UI
flow by thermal variations SC70 “Cargo tank vent Zone 1: open areas on
systems and selection of deck within a 3m radius.
electrical equipment”. Zone 2: additional 1.5m
beyond Zone 1;
IEC 60092-502, 4.2.2.7
and 4.2.3.1.
2 The separation distance At least 5m; SOLAS Reg. At least 10m; IBC Code At least 10m; IGC Code At least 6m; IEC 60092-
of the nearest air intakes II-2/11.6.2.2. 8.3.4.2. 8.2.10 and 2014 502, 4.2.2.7, 4.2.3.1 and
for non-hazardous amended IGC Code 8.2.5.
spaces from the tank At least 15m; IBC Code 8.2.11.2.
ventilation outlet for small 15.12.1.3 (although
flow by thermal variations toxicity not flammability). Cargo tank PRV vent
exits: at least equal to B
or 25m, whichever is
less. For ships less than
90m in length, smaller
distances may be
permitted; IGC Code
8.2.10 and 2014
amended IGC Code
8.2.11.1.
3 The separation distance At least 10m; SOLAS At least 10m; IBC Code At least 10m; IGC Code At least 11.5m; IEC
of the nearest air intakes Reg. II-2/4.5.3.4.1.3. 12.1.5. 12.1.6. 60092-502, 4.2.2.8,
for non-hazardous At least 10m; For tankers At least 15m; IBC Code 4.2.3.2 and 8.2.5.
4 The separation distance MSC.1/Circ.1321 Pt.IV At least 10m; IBC Code At least 10m; IGC Code At least 6m; IEC 60092-
of the nearest air intakes Ch.3 Para.1.2: the 12.1.5. 12.1.6. 502, 4.2.2.7, 4.2.3.1 and
for non-hazardous areas position of the cargo 8.2.5.
from the ventilation pump room vent outlet Ventilation ducts, air
exhaust outlet for should be arranged at a intakes and exhaust
hazardous areas (i.e. distance of at least 3m outlets serving artificial
cargo compressor room, measured horizontally ventilation systems shall
cargo pump room, etc.) from any ignition source be positioned in
and from the nearest accordance with
opening to recognized standards*;
accommodation, service 2014 amended IGC
or machinery spaces. Code 12.1.5.
* IEC60092-502(1999)
6 Opening to main cargo Subject to Administration; IBC Code 3.2.3. The intent of a minimum
control stations and SOLAS Reg. II-2/4.5.2.2. distance of 1.5m from
service spaces not giving Note: SOLAS Reg. II- the boundaries of any
access to 2/4.5.2.2 does not hazardous area is to be
accommodations, control categorize the space as followed; IEC 60092-
stations and similar hazardous or non- 502, 8.2.5.
spaces containing hazardous.
sources of ignition
7 Openings to Not less than 4% of L, but Not less than 4% of L, Not less than 4% of L, At least 1.5m from the
accommodation spaces, not less than 3m from the but not less than 3m from but not less than 3m from boundaries of any
service spaces, control end of the superstructure the end of the the end of the hazardous area; IEC
stations and machinery or deckhouse. (This superstructure or superstructure or 60092-502, 8.2.5.
spaces facing the cargo distance need not exceed deckhouse. (This deckhouse. (This
area 5m); SOLAS Reg. II- distance need not distance need not
2/4.5.2. exceed 5m); IBC Code exceed 5m); IGC Code
3.2.3. 3.2.4 and 2014 amended
IGC Code 3.2.4.1.
11 Concentration of gas 10% LFL (Lower 10% LFL for cargo pump Alarms should be 30% LFL; IEC 60092-
implying that space is Flammable Limit) for room; IBC Code 11.1.1.7 activated for flammable 502, 8.4.2.
non-hazardous (alarm cargo pump rooms in (Res. MSC.219(82)), products when the
limits) tankers; SOLAS Reg. II- clarifying that SOLAS vapour concentration Note: The requirement
2/4.5.10.1.3. regulation II-2/4.5.10 reaches 30% of the lower of the standard applies
applies, in which case flammable limit, for the to spaces protected by
30% LFL for all ballast “hydrocarbon gases” are spaces of 13.6.7 of the over-pressure.
tanks and void spaces of replaced by “flammable Code; IGC Code 13.6.10.
double-hull and double- vapours”.
bottom spaces adjacent 30% LFL for the spaces
* IEC 60092-502(1999).
As per the Note to 8.4.3
of the standard, a fan
motor or a fan rotation
monitoring device will not
satisfy this requirement.
14 Classification of cargo Hazardous zone IGC Code 1.3.17.7 IEC 60092-502, 4.1.4.1
pump room classification and 2014 amended IGC Table 1 and 4.2.2.4 may
electrical installation shall Code 1.2.24.6. indicate that cargo pump
be complied with IEC rooms are Zone 1.
60092-502(1999); SOLAS However, as ventilation
Reg. II-1/45.11. is only running during
cargo handling, the
requirements may be
interpreted that it is
Zone 0 (Flag
Administration position
may be required).
16 Gas carrier ballast tanks Ballast tanks may be Ballast tanks on gas
connected to pumps in carriers, separated from
machinery spaces; IGC a hold space, where
Code 3.7.4, 2014 cargo is carried in a
amended IGC Code cargo tank requiring a
3.7.5. secondary barrier, by a
single gastight
boundary, are
hazardous areas Zone
1.
18 Access to forward spaces Access openings to Reference is made to UI Reference is made to UI It is implied that as long
below level of main deck service spaces, control SC120 “Access to SC120 “Access to as the sill height is
stations and machinery forecastle spaces on forecastle spaces on above 0.5m then it is
spaces are not to face the tankers; SOLAS tankers; SOLAS exempted from SOLAS
cargo area; SOLAS Reg. regulations II-2/4.5.2.1 regulations II-2/4.5.2.1 and can face the cargo
II-2/4.5.2. Reference is and 4.5.2.2, IBC Code and 4.5.2.2, IBC Code area; IEC 60092-502,
made to UI SC120 paragraph 3.2.3 and IGC paragraph 3.2.3 and IGC 4.2.3.6.
“Access to forecastle Code paragraph 3.2.4”. Code paragraph 3.2.4”.
spaces on tankers;
SOLAS regulations II-
2/4.5.2.1 and 4.5.2.2, IBC
Code paragraph 3.2.3
and IGC Code paragraph
3.2.4”.
21 Location of fan motors for To be located outside To be located outside IEC 60092-502; follows
cargo pump room and ducts; IBC Code 12.1.8. ducts; IGC Code 12.1.9. zone classification. I.e. if
compressor room 2014 amended IGC Zone 0, outside
Code 12.1.7. ventilation duct (based
on 6.5.2). If Zone 1,
inside OK, provided
certified for Zone 1.
22 Openings to Shall not face the cargo Shall not face the cargo Should not face the Access doors or other
accommodation spaces, area. Can be located at area. They shall be cargo area. They should openings shall not be
service spaces, control the transverse bulkhead located on the end be located on the end provided between an
stations and machinery not facing the cargo area, bulkhead not facing the bulkhead not facing the area intended to be
spaces facing the cargo at a distance of at least cargo area and/or on the cargo area or on the considered as non-
area 4% of the length of the outboard side of the outboard side of the hazardous and a
ship but not less than 3m superstructure or deck- superstructure or deck- hazardous area, or
from the end of the house at a distance of at house or on both at a between a space
superstructure or least 4% of the length (L) distance of at least 4% of intended to be
26 Hazardous zone Hazardous zone IBC Code Chapter 10: IGC Code 1.3.17.8. The cargo tanks,
classification on main classification and IEC 60092-502(1999). 2014 amended IGC including all ballast
deck of tankers electrical installation shall Code 1.2.24.9. tanks with cargo tank
be complied with IEC area; IEC 60092-502,
60092-502(1999); SOLAS 4.2.2.11 & 4.2.3.5
Reg. II-1/45.11. (areas on open deck
over cargo tanks as per
the above IEC
paragraphs do not
coincide with the
definition of the cargo
area in SOLAS or the
Codes).
End of