Professional Documents
Culture Documents
TM-3541 AVEVA Plant (12.1) Schematic Model Manager Rev 3.0
TM-3541 AVEVA Plant (12.1) Schematic Model Manager Rev 3.0
(12.1)
TRAINING GUIDE
AVEVA Engineering
Schematic Model Manager
TM-3541
www.aveva.com
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
Revision Log
Date Revision Description of Revision Author Reviewed Approved
30/11/2011 1.0 Approved for Training 12.1 KI HU BT
07/12/2011 2.0 Issued with latest copyright KI HU BT
13/01/2012 3.0 Approved for Training 12.1.SP2 KI BT BT
Updates
All headings containing updated or new material will be highlighted.
Suggestion / Problems
If you have a suggestion about this manual or the system to which it refers please report it to AVEVA
Training & Product Support at tps@aveva.com
This manual provides documentation relating to products to which you may not have access or which may
not be licensed to you. For further information on which products are licensed to you please refer to your
licence conditions.
Disclaimer
1.1 AVEVA does not warrant that the use of the AVEVA software will be uninterrupted, error-free or free
from viruses.
1.2 AVEVA shall not be liable for: loss of profits; loss of business; depletion of goodwill and/or similar
losses; loss of anticipated savings; loss of goods; loss of contract; loss of use; loss or corruption of
data or information; any special, indirect, consequential or pure economic loss, costs, damages,
charges or expenses which may be suffered by the user, including any loss suffered by the user
resulting from the inaccuracy or invalidity of any data created by the AVEVA software, irrespective of
whether such losses are suffered directly or indirectly, or arise in contract, tort (including negligence)
or otherwise.
1.3 AVEVA's total liability in contract, tort (including negligence), or otherwise, arising in connection with
the performance of the AVEVA software shall be limited to 100% of the licence fees paid in the year
in which the user's claim is brought.
1.4 Clauses 1.1 to 1.3 shall apply to the fullest extent permissible at law.
1.5 In the event of any conflict between the above clauses and the analogous clauses in the software
licence under which the AVEVA software was purchased, the clauses in the software licence shall
take precedence.
www.aveva.com
© Copyright 1974 to current year. 2
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
Copyright
Copyright and all other intellectual property rights in this manual and the associated software, and every part
of it (including source code, object code, any data contained in it, the manual and any other documentation
supplied with it) belongs to, or is validly licensed by, AVEVA Solutions Limited or its subsidiaries.
All rights are reserved to AVEVA Solutions Limited and its subsidiaries. The information contained in this
document is commercially sensitive, and shall not be copied, reproduced, stored in a retrieval system, or
transmitted without the prior written permission of AVEVA Solutions Limited. Where such permission is
granted, it expressly requires that this copyright notice, and the above disclaimer, is prominently displayed at
the beginning of every copy that is made.
The manual and associated documentation may not be adapted, reproduced, or copied, in any material or
electronic form, without the prior written permission of AVEVA Solutions Limited. The user may not reverse
engineer, decompile, copy, or adapt the software. Neither the whole, nor part of the software described in
this publication may be incorporated into any third-party software, product, machine, or system without the
prior written permission of AVEVA Solutions Limited, save as permitted by law. Any such unauthorised
action is strictly prohibited, and may give rise to civil liabilities and criminal prosecution.
The AVEVA software described in this guide is to be installed and operated strictly in accordance with the
terms and conditions of the respective software licences, and in accordance with the relevant User
Documentation.
Copyright 1974 to current year. AVEVA Solutions Limited and its subsidiaries. All rights reserved. AVEVA
shall not be liable for any breach or infringement of a third party's intellectual property rights where such
breach results from a user's modification of the AVEVA software or associated documentation.
AVEVA Solutions Limited, High Cross, Madingley Road, Cambridge, CB3 0HB, United Kingdom
AVEVA Solutions Ltd, High Cross, Madingley Road, Cambridge, CB3 0HB, United Kingdom.
Trademark
AVEVA and Tribon are registered trademarks of AVEVA Solutions Limited or its subsidiaries. Unauthorised
use of the AVEVA or Tribon trademarks is strictly forbidden.
AVEVA product/software names are trademarks or registered trademarks of AVEVA Solutions Limited or its
subsidiaries, registered in the UK, Europe and other countries (worldwide).
The copyright, trademark rights, or other intellectual property rights in any other product or software, its
name or logo belongs to its respective owner.
www.aveva.com
© Copyright 1974 to current year. 3
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
Contents
1 Introduction .............................................................................................................................................. 7
1.1 Aim..................................................................................................................................................... 7
1.2 Objectives ......................................................................................................................................... 7
1.3 Prerequisites .................................................................................................................................... 7
1.4 Course Structure .............................................................................................................................. 7
1.5 Using this guide ............................................................................................................................... 8
2 Introducing AVEVA Schematic Model Manager ................................................................................... 9
2.1 Overview ........................................................................................................................................... 9
2.2 Operating Principles ...................................................................................................................... 10
2.3 Entering AVEVA Schematic Model Manager ............................................................................... 10
3 Schematic Model Manager Basic Use ................................................................................................ 13
3.1 Schematic Model Manager User Interface ................................................................................... 13
3.1.1 File Menu .................................................................................................................................. 13
3.1.2 View .......................................................................................................................................... 13
3.1.3 Import ....................................................................................................................................... 13
3.1.4 Edit Menu ................................................................................................................................. 14
3.1.5 View Menu ................................................................................................................................ 14
3.1.6 Tools Menu ............................................................................................................................... 15
3.1.7 SMM Toolbar ............................................................................................................................ 15
3.1.8 Schematic Model Viewer Toolbar ............................................................................................ 16
3.2 Schematic Model Manager Explorer ............................................................................................ 16
3.2.1 Schematic Explorer Element Right Click Menus...................................................................... 21
Exercise 1- Schematic Model User Interface .............................................................................................. 30
4 Import P&ID Data ................................................................................................................................... 31
4.1 Import Pre-requisites ..................................................................................................................... 31
4.2 Diagrams Preview – Worked Example ......................................................................................... 31
4.3 Import Diagrams Facility ............................................................................................................... 34
4.3.1 Import Diagrams –Worked Example ........................................................................................ 34
4.3.2 Import Diagrams Set – Worked Example ................................................................................. 37
4.4 Importing using PML ..................................................................................................................... 38
Exercise 2- Import ing P&ID Data ................................................................................................................. 40
5 Review Imported P&ID Data .................................................................................................................. 41
5.1 Review Imported Data Using Schematic Explorer and Diagram Viewer .................................. 41
5.1.1 Diagram Viewer Toolbar Description ....................................................................................... 43
5.2 Review Imported Data using Schematic Model Viewer.............................................................. 44
5.2.1 Generating Schematic Model for Import Schematic Equipments –Worked Example.............. 44
5.3 Schematic Model Viewer Toolbar Description ............................................................................ 46
5.3.1 Expand Option.......................................................................................................................... 46
5.3.2 Display Inline Items Option ...................................................................................................... 46
5.3.3 Settings Option ......................................................................................................................... 47
5.3.4 Schematic Symbol Settings ..................................................................................................... 53
5.4 Off-Page Connectors ..................................................................................................................... 54
5.4.1 Off-page Connectors of Imported Diagram .............................................................................. 54
5.4.2 Editing Existing Off-page Connectors ...................................................................................... 55
5.5 Imported Element Release Status ................................................................................................ 59
5.6 Highlight Changes in Diagram Objects Between Database Sessions ..................................... 61
5.6.1 Highlight Changes in Diagrams – Worked Example ................................................................ 62
5.6.2 Diagram Change Highlighting Toolbar ..................................................................................... 66
Exercise 3- Review Importing P&ID Data .................................................................................................... 70
6 Excel Import and Export ....................................................................................................................... 71
6.1 Formatting Excel Import Files ...................................................................................................... 72
6.1.1 Importing Excel Worksheets – Worked Example ..................................................................... 73
6.1.2 Exporting Excel Worksheet File – Worked Example................................................................ 83
6.1.3 Excel Import and Export Command Line Interface .................................................................. 87
Exercise 4- Excel Import and Export ........................................................................................................... 88
7 Creating and Editing Schematic Elements ......................................................................................... 89
7.1 Creating and Editing Schematic Elements using Edit Member Function ................................ 89
7.1.1 Creating Elements – Worked Example ....................................................................................
www.aveva.com 90
7.1.2 Duplicating Elements- Worked Example .................................................................................. 92
© Copyright 1974 to current year. 4
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
5
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
6
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
CHAPTER 1
1 Introduction
This training guide is for use with AVEVA’s Schematic Model Manager product. The product is a module that
can be licensed for use with an existing AVEVA PDMS or Marine installation. This chapter outlines the
objectives for this guide, details the knowledge required and what must be in place before training starts,
how to use this guide and the course structure.
1.1 Aim
Over the duration of the training participants will learn how to use the AVEVA Schematic Model Manager
application, importing P&ID data for use with Schematic 3D Integrator and PDMS.
1.2 Objectives
1.3 Prerequisites
Please see Help file Schematic Model Manager – Post Installation Tasks
Training consists of oral and visual presentations, demonstrations and set tasks. Training is executed in the
PDMS SAM training project. Appropriate XML files from AVEVA P&ID are provided and form the basis of
this training course.
www.aveva.com
7
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
Certain text styles are used to indicate special situations throughout this document, here is a summary;
Menu pull downs and button press actions are indicated by bold dark turquoise text.
Information the user has to key-in will be red and in bold Italics.
Annotation for trainees benefit:
Additional information
Refer to other documentation
System prompts should be bold and italic in inverted commas i.e. 'Choose function'
Example files or inputs will be in the courier new font, colours and styles used as before.
8
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
CHAPTER 2
2.1 Overview
AVEVA Schematic Model Manager is an application that supports the import of P&ID data in XML format
from any source that provides output which conforms to AVEVA’s interpretation of the ISO 15926 schema.
The ISO 15926 standard is a classification of engineering items, it is not a detailed description of how or
what is in any ISO 15926 xml output file.
The Schematic Model Manager application is a module of AVEVA Engineering that can be licensed for use
with an existing AVEVA PDMS or Marine installation.
Imported data is stored in a Schematic Database within PDMS. This data can then be used for 3D modelling
through the use of the Schematic 3D Integrator application (add-in to Design Module).
The Schematic Model Manager application creates a Scalable Vector Graphics (SVG) representation of a
diagram (P&ID) as part of the import process. This may be viewed using the Diagram Viewer which allows
the user to point and click navigation of the schematic data from the diagram, opens other diagrams linked
by offpage connectors and managed via a hierarchical data explorer know as Schematic Explorer.
This explorer also includes facilities for releasing selected schematic elements to the AVEVA Schematic 3D
Integrator, for integration with the 3D Design Model database.
www.aveva.com
9
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
Schematic Model Manager works as PDMS does & uses cached memory. To ensure consistency between
Schematic Model Manager and Schematic 3D Integrator please ensure the SaveWork function is executed
following an Import.
This action is necessary to cause the SVG rendition used by Schematic 3D Integrator to be created and
ensure that it is consistent with Schematic Model Manager data. The SVG rendition is typically located here,
C:\AVEVA\Plant\Projects12.1.1\project\xxxdia
The schematic data is organized into a fixed model hierarchy. The top level object is the Group object
SCGROU, which is an organising object.
The user can create, name and organise data at this level as necessary. Beneath this level the data is
organised as defined on the P&ID’s.
Schematic groups (SCGROU) can have further groups created beneath, if so desired.
The Schematics database also maintains references between schematic items and the diagrams that they
are represented on. This allows the user to, for example, find and open all diagrams where a specific
pipeline is depicted.
To start the AVEVA Schematic Model Manager application, Select All Programs > AVEVA Plant >
Engineer > Engineering 12.1 > Schematic Model Manager as shown:
10
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
Alternatively AVEVA Schematic Model Manager application could be access by double clicking on AVEVA
Engineer shortcut icon on the desktop as shown below:
AVEVA Schematic Model Manager login box will then be displayed as shown:
MDB: SAMPLE
11
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
12
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
Chapter 3
Schematic Model Manager is installed as an Engineering module that can be licensed for use with an
existing AVEVA PDMS or Marine installation and following a successful installation, the module is accessed
using menus and toolbars as described below:
3.1.2 View
Used to locate, display and previews of an XML file available for import in
the SVG viewer.
3.1.3 Import
www.aveva.com
13
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
The Edit Members dialog is used to create and editing elements. See Section 7.0
Catalog Search: This search facility provides direct access to the Plant or
Marine catalogue.
3.1.5.1 Explorers
14
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
Set Release Status: Used to set the release status of the current
element, i.e. to release it to or unrelease it from the 3D model. See
Section 5.5
Source Dictionary Management: Accesses tool for maintaining the Source Data Dictionary which is used
to visualise the potential contents of import files when editing the attribute mappings and to keep track of
metadata about source files such as the source systems which data has come from.
Line List Options: Accesses facilities for specifying the settings which define how line lists will be
generated.
For more details on Attribute, Gtype Mapping, Attribute Derivation Rules, Source Dictionary
Management, Line List and Project option, please refer to TM-3542 AVEVA Schematic Model
Manager Training Guide (Admin).
15
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
Used to set the release status of the current element, i.e. to release it to or unrelease it from the 3D
model.
Accesses the Diagram Connector, which is used to manually connect page connectors between
imported diagrams.
In addition to the menu structure above a toolbar for the Schematic Model Viewer is also installed.
This can be accessed by Right clicking on the main toolbar and select Schematic Model Viewer.
The Schematic Model Viewer toolbar is not displayed if MS Visio 2007 professional is not
installed.
The Schematic Model Manager Explorer is used to review and navigate the Schematic Database. If the
Schematic Model Manager Explorer is not visible, it can be displayed by selecting the
View > Explorer > Schematic Explorer menu function from the Schematic Model Manager menu
16
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
The Schematic Model Manager Explorer behaves identically to the PDMS Design Explorer and has its own
right mouse button menu providing additional options.
The Schematic Model Manager Explorer can be moved to any position within the screen
display or fixed into a specific location within the PDMS display.
Each element in the Schematic database is assigned a element type (TYPE). Elements in the Explorer are
arranged by TYPE, in the following hierarchy:
Schematic Worl *
STLNKW
STLNKS(May contain further STLNKS)
STALNK
SCGROU (may contain further SCGROUs)
SCPLIN
SCBRAN
SCSEG
SCTUB
SCVALV
SCINST
SCFITT
SCOPCO
SCOPCI
SCPDES
17
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
SCDUCT
SCHVFI
TEXT
TEXT
SCHVAC (same as under SCPLIN - see above)
SCEQUI
SCSUBE
SCNOZZ
SCELCO
TEXT
SCNOZZ
SCELCO
TEXT
SCOINS
TEXT
SCMCAB
SCCAB
SCCORE
SCCAB
SCCORE
SCDIAG
SPAGE
SCIND
SCTEMP
SCSTEN
SCLOOP
SCILIN
(Same as under SCPLIN)
SCACTU
Note: Element Types in italics cannot be imported into the database using Schematic Model
Manager. However, they can be created using other methods such as the Create menu options
or the command line, so they may appear in Explorer.
Schematic Worl *: Topmost level of the Schematic database hierarchy within which all other elements exist
cannot be moved, renamed or deleted.
Note: STLNKS may contain other STLNKS, which in turn may contain STALNK elements or
more STLNKS. STALNK : Status Link.
By default, groups for Diagrams, Instruments, Equipment and Pipeline are created automatically
when these elements are imported into the database.
The default groups can be changed using the option dialog or by setting the OWNER attribute
using the attribute mapping facilities. See section 4.8.
18
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
SCPLIN: Pipelines
SCBRAN: Pipe branches
SCSEG: Page/Pipe segements
SCTUB: Tubing.
SCVALV: Valves.
SCINST: Inline Instruments.
SCFITT: Inline Fittings.
SCOPCI: Off-page connection (in).
SCOPCO: Off-page connection (out).
SCPDES: Pipe destination.
SCDUCT: Ducting.
SCHVFI: HVAC fitting.
SCHVAC: HVAC.
TEXT: Text elements are used to store information about the
identity of elements. This is provided for use by the
system and these should not be deleted or renamed by
users.
SCEQUI: Equipment.
SCSUBE: Sub-equipment.
SCNOZZ: Equipment nozzles.
SCELCO: Electrical connections.
19
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
20
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
The right click menus is used to perform actions on an element, accessed by selecting an elements on the
Schematic Explorer and then right-click on it to display context menu.This is discussed in full in section
below:
The Highlight Changes option allows the user to highlight changes made. The user can choose to either
display the Latest changes or choosing to highlight the changes between two sessions.
The Highlight Changes option contains Latest and Choose Sessions sub-options. Accessed from
Schematic Explorer context menu by selecting any SCGROUPs elements such as Scpline, Scequi, Scoins,
Scdiag etc as shown below.
21
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
The Set Release Status option displays the Set Release Status window.
The element in the Schematic database is made accessible to the AVEVA Schematic 3D Integrator for
integration with the 3D Design Model database,when the element release Status is set to ON
The Attributes option is used to view attributes of the current element. To view the attributes of an element,
right-click on the element and select the Attributes option.
The Attributes form is then displayed, on which the attributes of the selected element are displayed.
22
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
The Attributes form can also display attributes in a grouped by category. Right-click on the Attributes form
and select Categorised/Aphabetical option from the submenu as shown:
To return the form to list view, click again on the Categorised/Aphabetical option from the right-click
submenu as shown:
The displayed attributes of selected element can be filtered to only display required attributes category as
described in this example. Right-click on the Attributes form and select Modify Category filters option
from the submenu to display available catergories.
23
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
Select the Uncheck all option and then check the required category in this case “Default”. Click the Ok
button to apply the filter as shown:
Click on the filter icon , select Check all option and click on the Ok button as shown:
Alternatively right-click on the Attributes form and select Manage Category Filters option from the
submenu to display the Manage Category Filter by Element Type form.
Then select required type and click on the Delete Selected Filter(s) option from Manage Category Filter
by Element Type form to delete the filter from the selected element type.
24
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
The Diagram Connector option is used to open the Diagram Connector, used to edit existing connections,
and to set connections between Off Page Connectors that were not established on import. This option is
only enable if an offpage connector is selected as shown:
If the current element is a schematic diagram, the Show Diagram option is used to open that diagram in the
Diagram Viewer. This option is disabled if the selected or current element is not schematic diagram element.
25
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
The Show in Diagram option is used to open the Diagram Viewer and displays the diagram in which the
current or selected element is located.
The option Show in Diagram is disabled if the “Text” element is selected as shown below.
26
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
The New option displays a sub-menu from which elements can be created.
The Edit Member options displays a sub-menu from which multiple elements can be created and edited.
27
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
The Add Link option is used to create a link element, i.e. a link between the current element and an external
document or URL.
The Rename option is used to change the name of the current element.
28
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
The Delete option is used to delete the current element and elements beneath it in the element hierarchy.
The New Explorer option opens a sub-menu from which another Explorer window can be opened,
displaying the current element and its members.
29
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
2. Select Schematic Equipment Item from Schematic Explorer and display its Attributes.
30
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
Chapter 4
AVEVA Schematic Model Manager is used to import P&ID data into a PDMS Schematic database. The
P&ID data is imported from an XML file, which complies with AVEVA’s interpretation of ISO 15926. An ISO
15926 XML file may be imported from AVEVA P&ID and from any other P&ID System that outputs an ISO
15926 compliant XML file.
Once imported, the P&ID data in the schematic database can be viewed and managed via a hierarchical
data explorer (Schematic Model Manager Explorer) or reported on via one of the PDMS reporting
mechanisms.
The XML files for importing contain engineering item and graphical data. There is a validation check on XML
files prior to importing confirming that these files are consistent and comply with the ISO 15926 schema
definition.
And before importing P&ID data users are advised to complete the following procedures:
For further details on pre-import configuiration, please refer to AVEVA Schematic Model Manager
Training Guide (Administration) TM-3542
If on import a file is found to be invalid, an error message is displayed, listing the invalid file and describing
the error. The error must be corrected for this file to be imported; there is no partial import option.
Possible causes of invalid files are unsupported primitives, foreign language character, and
incorrect format of the values or incomplete item descriptions.
Diagrams which are available for import can be previewed. By selecting File > View… from the Schematic
Model Manager Module main menu.
www.aveva.com
31
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
Select the XML file(s) of the diagrams to preview and then press the Open button to display Diagram Viewer
dialog.
To close a diagram, right-click on the diagram tab, and select the close option from the menu
that is the displayed.
32
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
Once the Diagram Viewer is open, use the View Diagram dialog to select and open existing imported
diagrams in Schemaic database, select the View Diagram button from the Diagram Viewer toolbar:
Check the Preview checkbox and select the required diagram from the Diagram Page list. The preview is
then displayed in the left-hand window. Select it from the list and press the OK button. The diagram open is
then displayed on a tab, labelled with the diagram name in the Diagram Viewer.
The displayed diagram may be printed by right clicking on the displayed diagram and select
Print Current Diagram function from the submenu.
33
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
There are two import facilities available from the Schematic Model Manager menu;
Diagrams
Diagram Set.
Both import facilities can be accessed from Schematic Model Manager main menu File > Import
To import diagram, select File > Import >Diagrams from the Schematic Model Manager main menu. The
Open dialog will then be displayed, listing all the files of diagrams in the default import file
The Open dialog will then be displayed, listing all the files of diagrams in the default import file
The default import file location is specified using the User Option dialog. See TM-3542 Schematic Model
Manager Training Guide (Admin) for more details.
Select the required XML file(s) of the diagram to import in this case ”A1-51-2009-1”and then press the Open
button.
34
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
The Release Comments dialog will is displayed. Add a release comment if required, which is stored against
each “Released element”. Then press the OK button.
User can specify the display of Release Comments Dialog and set the release Behaviour of
Elements on import by using the Project Option dialog. Please refer to AVEVA Schematic
Model Manager Training Guide (Administration) TM-3542 for more details.
The status of each task is displayed in the Status column and indicated by an icon in the first column
Ready:
Cancelled:
Runing: Completed:
Completed with warning
Failed
35
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
The Summary and Error Tabs on the Import Progress Dialog displays the textual description of the import
and a list of import errors respectively
Then press the Dismiss button from the Import Progress Dialog to close the form. The import diagram may
be viewed from Schematic Explorer as shown:
Select a diagram(s) from Schematic Explorer, right-click, and select Show Diagram from the
menu that is then displayed.
After the data has been imported, it must be saved to the database with the ‘savework’ function.
Imported Schematic may be displayed in the Diagram View, by selecting a diagram(s) in the
Schematic Model Manager Explorer, and drag and drop them into the Diagram Viewer Dialog.
36
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
Diagram set is a group of diagram XML files; they can be recalled and re-imported as required. The File set
are created and edited using the Diagram Set Editor.
To create the import file set select File > Import > Diagram Set Editor. The Diagram Set Editor dialog will
then be displayed.
Select the Add Diagram button to add a single or multiple files to a new Diagram Set
The Open dialog will then be displayed. Browse for and select the required diagram “A1-51-2009-1” to add
to the Diagram Set and the press Open button
37
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
The selected file(s) will then be displayed in the diagram list section of the Diagram set editor dialog
To clear the screen, select the New Diagram File set button to clear the screen.
To save the new Diagram Set, select the Save Diagram set button from the Diagram Set Editor dialog.
P&IDs can also be imported in non-graphics mode using PML. This enables batch scripts to execute imports
without user interaction.
Create a file in the Testlmport folder and save the file as import.bat with the following content:
../ Engineering tty <project> <user>/<password> /<mdb> $M/import.mac
Create a file in the TestImport folder and saved the file as import.mac with the following
contents:
SchematicModelManager
!pid = object smm()
!result = !pid.ImportFile('<P&ID filename and path>')
if (!result NE -1) then
savework
endif
finish
Run import.bat either from a command prompt or by double clicking on it from the file explorer
All imports are executed using an instance of the PIDManager PML object. To create A PIDManager object
enter the following in the command line:
!pid=object smm()
To see the method available on this object enter the following using the command window
Q methods !pid
If it is the first time the command line is used to import P&IDs the user may need to enter
38
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
PML REHASH ALL using the command window to update the PML library index file. If this hasn't been done
an error message will be displayed.
There are three ways of importing diagrams using the Command Window.
To import a single diagram enter the following using the command window:
To import the diagrams in a folder enter the following using the command window:
!Pid.importfilesindir('Folder','Release Comment')
To import the diagrams in a Diagram Set enter the following using the command window:
!Pid.importfromfileset('diagram set’)
Note: In any of the above method the Command Window displays progress, error and warning
messages as the import is carried out, for example:
A return value is provided that indicates the success (or otherwise) of the import operation
All import messages, warnings and errors are written to a log file. A new log file is created for every time
Schematic Model Manager is run.
Imported data is not saved into the Schematic database until a Save Work takes place. To save changes to
the database using the command line, enter 'savework' at the command prompt.
39
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
40
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
Chapter 5
Imported P&ID data in the schematic database can be viewed and reviewed using options:
5.1 Review Imported Data Using Schematic Explorer and Diagram Viewer
Select a diagram(s) in the Schematic Model Manager Explorer, right-click, and select Show
Diagram from the menu that is then displayed.
Or select a diagram(s) in the Schematic Model Manager Explorer, and drag and drop them into
the Diagram Viewer Dialog.
www.aveva.com
41
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
Click Schematic Equipment Elements (C1101) contained within the displayed diagram from the Diagram
Viewer dialog. The selected item is then enclosed in a red dashed line and becomes the current element
and is selected in the Schematic Explorer as shown:
Click Schematic Pipeline (B-1) contained within the displayed diagram from the Diagram Viewer dialog.
The item is enclosed in a red dashed line. It becomes the current element and is selected in the Schematic
Explorer as shown:
42
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
View Diagram - used to view diagrams that have been imported. Not used to preview un-imported
diagrams. See Section 4.2
Diagram Changes Highlighting– used to view database changes related to diagram objects between
two database sessions or stamps and highlight the changes using different colours. See Section 5.6
Zoom to Selection - zooms to a selected area of the diagram. Select this button then select the area by
left-clicking on one corner of the area and then dragging the cursor to the opposite corner of the area
Zoom to Window - zooms out so that the entire diagram is visible. This option is also available from the
menu that is displayed by right-clicking on a diagram
Set Bookmark - saves the current view - saved views are known as bookmarks
Previous Bookmark - sets the view to the bookmark that was set before the current bookmark
Next Bookmark - sets the view to the bookmark that was set after the current bookmark
If the cursor is hovered over this button, a tooltip displaying information on keyboard commands is
displayed.
43
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
The Schematic Model Viewer provides the user with the ability to view and navigate the contents of the
schematic model database based upon physical connection rather than logical connection (database
hierarchy) or diagram layout.
It provides a continuous navigable view of equipment items and the interconnecting piping networks,
independently of which system they belong to or which P&ID they have been drafted on.
The Schematic Model Viewer is implemented as a Common Application Framework (CAF) Add-In, which
means that it can be hosted by different applications. The viewer requires access to a Schematic database
included in the current MDB
The Schematic Model Viewer is a new approach to viewing the entire consolidated schematic model that
has been imported into the Schematic database.
5.2.1 Generating Schematic Model for Import Schematic Equipments –Worked Example
Users can use the Schematic Model Viewer to display the imported schema centred on selected equipment
items.
To activate the Schematic Model viewer, select the New Schematic Model View button from the Schematic
Model View toolbar, and then select the schematic equipment element P1502B from the Select Equipment
form.
44
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
To item re-positioned the selected equipment at the diagram’s center, select the require equipment icon and
select the Center option from the Right Mouse Button menu. The Schematic Model View is re-generated
with the selected equipment item re-positioned at the diagram’s center.
.
The center item option can also be accessed from Schematic Model Viewer Toolbar
Command Result
45
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
The Schematic Model Viewer toolbar as shown that allows the user(s) to control the Schematic Model
Viewer behaviour.
Using the Expand command allows all connections to that item will be traversed and expanded.
To display all connections to a selected item click on the Expand command on the toolbar or from the Right
Mouse Button menu. This will generate a new schematic view as shown.
And to restore the view to its previous state, selecting the Collapse option as shown:
By selecting the View Inline Items command, the viewer will change into a mode in which all inline fittings
are shown. These will be placed along the lines between the branching points, like knots on a piece of
string.
The branching points will also be illustrated by an icon representing the kind of fitting it is, rather than
the generic branching point icon used when inline fittings are not shown.
46
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
To display inline items such as valves, reducers, instruments etc. select the Show Inline Items icon from
the toolbar. The view will then display all the schematic inline fittings of the selected element as shown:
It is now possible to individually control the shape annotations for the element types in Schematic Model
Viewer. The following settings can now be made using the Options dialog in Schematic Model Viewer:
47
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
- Show Arrow – Show flow direction using arrows. You can determine size of arrows using drop
down list.
48
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
- Display Text
- Line Colour
- Line Patters
- Line Weight
- Object Visibility
This xml are pointing to symbol file which is responsible for symbol settings:
<SymbolFilepath="%PDMSEXE%\SchematicSymbols.xml"></SymbolFile>
Display Text
This is the text that is displayed on an item. User can use bracket to get attribute value. For example in
Schematic module the owner and name attributes can be displayed for Pipelines as shown:
49
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
Click on the Apply or OK button. This will apply the changes to the schematic view.
Line Colour
This option is used to change line colours for required connection type. If required, select the Line Colour in
this case Pipelines and click on the desired colour.
Click on the Apply or OK button.This will apply the changes to the schematic view as shown:
50
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
Line Patterns
This option is used to change line patterns for required connections types. To do this; select the Line
Pattern, in this case Pipelines and click on the desired Line Pattern as shown:
Click on the Apply or OK button. This will apply the changes to the schematic view
51
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
Line Weight
This option is used to set weight of line for required connections types. To do this; select the Line Weight, in
this case Pipelines and click on the desired Line Weight as shown.
Click on the Apply or OK button button. This will apply the changes to the schematic view
52
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
Object Visibility
This option is used to show/hide desired element types. In this example to hide OpenEnd object, select the
object and click on false from the pull-down list.
The symbol settings are stored in an XML format file (Symbol file) at the following location
<SymbolFile path="%PDMSEXE%\SchematicSymbols.xml"></SymbolFile>
Icons used to represent the equipment items, generic branch points as well as inline fittings are determined
by a set of user configurable rules.
53
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
However if the system will not find shape or stencil then the relevant icon will be used. And if icon, shape
and stencil are not found default rule will be used.
As part of the import process, Schematic Model Manager attempts to match any off-page connectors
(OPCs) on the imported diagrams with those of diagrams already in the Schematic database.
Most often connections between Off-Page Connectors (OPCs) may be established when diagram data is
imported.
The Diagram Connector is used to edit existing connections, and to set connections between OPCs that
were not established on import.
To review any off-page connectors (OPCs) on the imported diagrams with those of diagrams which existed
in the Schematic database.
Right-clicking on an off-sheet connector element in an imported drawing and select the “Go To Connected
OPC” option.
The “Go To Connected OPC” option is greyout if there are no corresponding / appropriate off-
page connectors (OPCs) found in Schematic database.
54
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
The corresponding matching off-page connectors (OPCs) of the diagram already in schematic database is
then be displayed as shown
Connections between Off-Page Connectors (OPCs) may not be established when diagram data is imported.
To set connections between OPCs that was not established on import.
Select Tools > Diagram Connector... option from the Schematic Model Manager Module main menu.
This displays the Diagram connector dialog:
55
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
Alternatively the Diagram connector dialog can be accessed by right-clicking on an off-sheet connector
element in the element hierarchy of the schematic Explorer
Access can also be by selecting the button on the SMM toolbar to display the Diagram
Connector dialog.
If the selected element is an off-page connector, the Source OPC field is populated with the connector of
the selected OPC. If there is already a connection set up for that off-page connector, the connected off-page
connector is displayed in the Target OPC field. Otherwise, the field will be blank
“Source” does not indicate that a connector is a SCOPCO (connector out) and “Target” does not
indicate that a connector is a SCOPCI (connector in).
In this context “Source” connector is the subject of this procedure, to which a selected “Target” connector is
connected.
If the Diagram connector dialog was opened from the Schematic Model Manager menu and the current
element (CE) was not an off-page connector, both fields will be blank. The source connector must therefore
be selected.
56
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
Right-click on an off-sheet connector element (OPC) on an imported diagram and select the Diagram
Connector option.
The Diagram Connector dialog is displayed. Select the browse … button next to the Source OPC
field from the Diagram Connector dialog
57
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
Connectors that are not currently connected are indicated by Red Cross in the first column.
Select the required connector by double-clicking the selected “OPC” or click on it once and press the
OK button.
In Target OPC Browser dialog, connectors that are not currently connected are indicated by
Red Cross in the first column
Target off-page Connector must be different from Source off-page connector. For example if
the source off-page connector is a SCOPCO, the target must be a SCOPCI
Once a connector is selected, the Source OPC field is populated with the name of the selected connector.
To connect the source and target OPCs Press the Connect button on the Schematic Model Manager
Diagram connector dialog.
58
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
The element in the Schematic database is made accessible to the AVEVA Schematic 3D Integrator for
integration with the 3D Design Model database,when the element release Status is set to ON
When an element is released, all its “child” elements (i.e. the elements beneath it in the database, such as
the nozzles of an equipment item) are released as well. Such elements cannot be released independently of
their parent elements
Elements can be released when they are imported, depending on the settings specified on the Project
Options dialog. If they are not released during an import, they can be released using the Set Release
Release Status option.
For further details on Project Option configuiration, please refer to AVEVA Schematic Model
Manager Training Guide (Administration) TM-3542
Only following types of element can be released: SCDIAG SCEQUI SCOINS SCSEG
Access this option either by selecting the Set Release Status Option from Schematic Explorer right click
menu or Tools > Set Release Status ... option from the Schematic Model Manager Module main menu.
59
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
The dialog displays the name of each element and its current release status. It also displays the date that
the release took place and the identity of the user that performed the release.
Each listed element has a checkbox next to its name. If the checkbox is checked, this indicates that the
element has been released.
To unrelease a previously released element, uncheck its checkbox. The checkboxes of its child elements (if
any) are not automatically unchecked.
Then click the Set Status button to complete the changes to the release status of the selected elements and
close the dialog. To close the dialog without implementing any changes, click the Cancel button.
60
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
Highlight Changes is an add-in used by AVEVA Schematic products. The tool provides users the capability
to view database changes related to diagram objects between two database sessions or stamps and
highlight the changes using different colours.
The Highlight Changes option contains Latest and Choose Sessions sub-options. Access from
Schematic Explorer context menu by selecting any SCGROUPs elements such as Scpline, Scequi, Scoins,
Scdiag etc. As shown below.
The Diagram Change Highligting can also be accessed by selecting Diagram Change Highligting icon
from the Diagram Viewer main toolbar as shown.
61
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
In this worked example, the highlight changes feature is used to compare database differences of a diagram
items between two SMM sessions
Select a Diagram element listed on the Explorer hierarchy and from context menu, select Highlight
Changes > Choose Sessions option from the sub-option. The Select Diagram and Session to Compare
Dialog will be displayed with the diagram name in the Diagram Element text box.
The Select Diagram and Sessions to Compare” dialog allows for selection of diagram elements
and two sessions and/or stamps from the current database.
62
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
The Select Diagram Element dialog will display a hierarchy containing elements having SCDIAG types as
their members. Selecting a node from the tree will display a list of diagram (SCDIAG) elements.
Select the diagram “A1-51-2009-2” and click OK button, this will return control to the Select Diagram and
Session to Compare and update the diagram name in the Diagram Element text box.
63
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
Select require Target Session or stamps from the current database, by clicking on the browse button next to
Target Session field. The Select Session dialog will be display with list of sessions available for the
selected element.
Select the required session by clicking a row from the grid and click OK button. This will return control to the
Select Diagram and Session to Compare and update Target Session text box, based on the button used
to invoke this dialog.
64
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
Set the Base Session, by clicking on the browse button next to Base Session field, Select Session dialog
will be displayed with a list of sessions available for the selected element.
65
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
On completion of the comparison process, the compared diagrams will be displayed on the Diagram
Change Highlighting form with colour highlighted components/elements, indicating attribute and element
differences.
Additional information such as Diagram Name, Page Number, Base and Target session details
are displayed on the Status bar as shown below.
If selected diagram contains multiple pages, each page will be loaded in separate tab within the
Diagram Change Highlighting add-in window.
The comparison result grid as highlighted below lists the details of new, modified or deleted item(s) between
the selected sessions or stamps.
The displayed element on the comparison result grid can be filtered with grid filtering tool. If the
filter is not displayed, right-click on the grid and select the Enable Filtering option as shown
above.
The comparison result can be exported Excel file, using the Export To Excel functionality
accessed from the grid right-click menu.
The Diagram Change Highlighting dialog toolbar contains various buttons and control for performing
different task as described in the example below.
66
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
5.6.2.1 Diagram Change Highlighting – Using New Element Option – Worked Example
In this worked example, use the Highlight New Elements option to highlight only new element on the
resultant diagram from worked example in section 5.6.1
To achieve this;
Click on the Highlight New Elements icon from Diagram Change Highlighting main toolbar. The
new element(s) are highlighted in “green” as shown
For further details on Highlight Colour Configuration, please refer to AVEVA Schematic Model
Manager Training Guide (Administration) TM-3542
5.6.2.2 Diagram Change Highlighting – Using Highlight Deleted Elements Option– Worked
Example
In this worked example, use Highlight Deleted Elements option to highlight only deleted element on the
compared diagram from worked example in section 5.6.1
To achieve this;
67
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
Clicking on the same the “Highlight Deleted Elements” icon the second time removes the highlighted if
required.
Deleted elements will only be highlighted if there are deleted elements in the selected target
and base sessions
Modified items are elements whose attribute values/data differ between the selected target and base
sessions. In this worked example, using Highlight Modified Elements functionality, highlight only modified
element on the compared diagram from worked example in section 5.6.1
To do this;
Click on the “Highlight Modified Elements” icon from Diagram Change Highlighting main toolbar. The
modified element(s) are highlighted in “magenta” colour using the “Items Modified” colour setting.
Click on the ‘Auto Zoom on Selection’ button to zoom onto selected item from the Diagram Change
Highlighting main toolbar. Then click on the required row from the comparison result grid to zoom on
selected element as shown
68
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
To apply a filter to the comparison result grid, select the required column row in this case “Modified
Element” and click on the Modified element check box as shown.
Only the Modified element is then displayed in the grid as shown above.
To start new comparison, clicking on the “Start New Comparison” icon, will display
“Select Diagram and Sessions to Compare” dialog required for starting a new comparison.
To refresh current diagram, click on the “Re-Compare Selected Session” icon. This will
redo the comparison, and update results. It is mainly useful when the comparison is between
the last saved session and in memory session.
To print current diagram, clicking on the “Print Diagram” icon this will displays the printer
selection dialog.
Click on the “Zoom In” icon, to Zoom in to the diagram.
Click on the “Zoom Out” icon, to Zoom out of the diagram.
Click on the “Zoom to Fit” icon, to Fit the diagram to the viewer window and maintains aspect
ratio.
69
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
70
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
Chapter 6
The Excel Import and Export feature supports the import and export of Excel Workbook files to/from
Dabacon database. This tool is common to AVEVA Diagrams and AVEVA Schematic Model Manager (Plant
& Marine).
Import of attribute data such as operating pressures and temperatures from external system.
The import of elements generated in an external system, such as Equipment and Nozzles.
Hierarchical Import.
Select File > Import > Import from Excel... option from the Schematic Model Manager main menu.
Select File > Import > Import from Excel... option from the Schematic Model Manager Module main
menu.
Alternatively click button Import/Export Icon from the Schematic Model Manager Module main toolbar.
www.aveva.com
71
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
The Excel Import feature is used where an excel file is used for an import. The excel file may contain
multiple worksheets and the content of the import file is used as the input for this function.
The import file must contain One Element Type per Worksheet, including UDETs.
The first row of the file must contain a list of headings. Each heading represents a column in the file
containing an attribute of the elements being loaded.
Item creation will require OWNER column. If this column is present, the owner of an element in
an import file must either exist in the import file, or already exist in the Dabacon database.
Below is an example of an Import file containing Equipment and related Nozzles with one element type per
worksheet.
When importing an excel file containing new elements to Dabacon database, it is important that users
comply with the following conventions:
Any reference to the name of an element should be preceded by a forward slash (/). For
example Equipment Tag Name P-9002B, should be represented as /P-9002B as highlighted
above.
72
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
If the name of the element is not preceded by a forward slash (/), the item(s) will be imported
without the name.
Any reference to the owner of an element should be preceded by a forward slash (/). For
example if an item with Tag Name P-9002B is owned Equipment group, it should be
represented as /Equipment as highlighted above.
Before the import process, it is important to confirm that the owner of element(s) in an import file
exist in the import file, or already exist in the Schematic database. And if no owner exists in
Schematic database, the user (s) is required to create the required Schematic Group
(SCGROUP) in Schematic Explorer.
In this example SCGROUP containing one SCGROUP element named /Equipment is created
in Schematic Model Manager Explorer.
If no appropriate owner exists in Schematic database, the import process will fail, and an error
message will be displayed.
This example illustrates the use of the Excel Import function in Schematic Model Manager to import Excel
Workbook files e.g. Equipment and related Nozzles to Dabacon database (Schematic Database).
Select File > Import > Import from Excel... option from the Schematic Model Manager Module main
menu or alternatively click on the Import Icon from the Schematic Model Manager Module main toolbar
as shown below:
73
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
Select File to Import dialog is then displayed. Navigate to the folder containing your import file and
select and click Open button to display the Excel Interface Wizard- Import dialog.
From Excel Interface Wizard- Import dialog If Configuration Name exists, it will be available for
selection from the Configuration Name drop-down menu.
Configuration Name is not mandatory, it is only required if the user needs to the save the
Configurations for future use.
And if no Configuration Name exists, user(s) may enter their preferred name. In this case enter
“EQUIP LIST TEST”
Select the required Data Mode to use for the import, in this case click on Element Type radio button
as highlighted above
For details on how to use Database View(s) Data Mode. Please refer to Common Design
Functionality Guide
From Excel Interface Wizard- Import dialog, click Next button to display the Worksheet and
Element Type Configuration dialog.
74
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
Click in the Element Type textbox to reveal a drop down, from a drop down list of the valid element
types for the schematic database type as shown below. This is required if the Import Wizard made no
element type suggestion or an inappropriate suggestion.
Then map the displayed worksheets column to the appropriate or required database element in this
case SCEQUIPMENT and SCNOZZLE shown above.
Ticked the Include All check box as highlighted above, this will automatically check the “Include” column
checkbox as highlighted as above.
Worksheets where ‘Include’ column is unchecked, but database Element Type is specified will
not be imported
Also worksheets where ‘Include’ column checked box is checked, but no database Element
Type is specified will not be imported.
To delete or remove any row, select the required row and then select the delete icon to remove
the row.
To continue; click on the Next button from Worksheet and Element Type Configuration dialog to
display the Column and Element Configuration dialog as shown below:
The the cells within the ‘Excel Column’ are automatically with the column headers (attribute names)
from the excel worksheet for import
75
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
Select the required Worksheet from the Worksheets section of the Column and Element
Configuration form, in this case SCEQUIPMENT.
Select the required Excel Column, click on the Attribute cell and then select the required database
attribute from the drop down list as shown.
76
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
Check the “Update All” checkbox, ‘Update’ rows checkboxes are automatically checked. This allows the
available columns to be included in the import process. If some columns are not required, they will be ingnored
during the import by unchecking the ‘Update’ checkbox
Leaving the ‘Update’ checkbox unchecked will allow the attribute to be processed during import
matching process and any difference will be highlighted in the Accept and Reject form, but will not
update the required database attribute.
77
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
Once the required configuration in Column and Element Configuration has been completed as shown
above, Click on the Next button, the Save Configuration Changes form is displayed.
To save the configuration check the Save the Configuration check box and enter preferred configuration
name, in this case enter “EQUIP LIST TEST”.
Then click the Finish button. The Excel Wizard then scans the Dabacon database and determines what
changes will take place if the import is confirmed. And if there database is large amount of item to be import
a progress bar may be shown indicating the progress of the database scan.
Once the processing of the source data (Excel import data) is completed, the Accept/Reject form will then
be displayed with a list of potential changes as shown:
The Accept/Reject-
Items tab displays
processed items
from the Excel
spreadsheet. The
content may be
sorted or filtered by
clicking on the filter
icon on the column
headers as
highlighted
At this point no changes are made. The import may be cancelled without affecting the contents of
the schematic database.
78
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
Below are the descriptions of the contents of the “Accept/Reject” form Item tab toolbar:
- Accepted Column - Displays checkboxes. If the update described in the ‘Items tab’ for the row is
required, then check box must be checked.
checkbox.
- Name Column - Displays the name of the database element that will be created or updated by the
import.
- Matched Column - Displays a checkbox which indicates if the row item has been matched to an
existing database item.
- Changes Column - Displays a count of attributes found in the database that have been selected to
be updated, and where the database value differs from the import value.
79
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
- Differences Column - Displays a count of attributes found in the database that are mapped to
columns but not selected for update and where the database value differs from the import value.
The “Difference” column shows the number of attributes found in the database where the
database value differs from the import value, but have not been selected for updated in Column
and Attribute Configuration page of the Excel import wizard.
- Type or ACTType Column – Display the element Type of the database element.
- Select and right clicking on any of the rows in the Accept/Reject - Items tab, a submenu is then
displayed as shown below;
For further details on Accept/Reject – Item tab submenu, please refer to PDMS Design Common
Functionality User Guide.
80
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
After reviewing all the required columns or items in the Accept / Reject - Item tab, select Accept / Reject to
display Accept / Reject tab grid. Check the Accept All checkbox to accept all the changes or updates as
shown
User(s) can reset the Accept/Reject Grid feedback colour to any preferred colour, right click on any of the
rows to display a submenu and then select Feedback Colours function as shown.
To start the import process, click the OK button from the Accept/Reject tab as highlighted.
After this point it will not be possible to undo changes made during the import. Unless the PDMS
session is exited without performing a savework.
81
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
An import progress dialogue will then be displayed indicating the progress of the import.
A successful completion of the import process will have the items displayed on Accept/Reject form imported,
as well as apply all accepted changed or updates to the schematic database as shown
The imported item(s) is usually displayed in the Explorer under a default schematic group
(SCGROUP) or Owner specified in the import file.
82
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
Excel export option is a feature used to export item(s) from Dabacon database (schematic database in this
case) to an Excel output.
Start the Export Wizard either from the File menu or from the Export toolbar, the Excel Interface Wizard -
Export is then displayed.
Select the Configuration Name created during the import example, which in this case is “EQUIP LIST
TEST” and click the NEXT button.
83
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
The Worksheet and Element Type Configuration wizard form will then be displayed, showing the saved
configuration setup defined during the import process.
This adds a new row to the grid. This allows an additional worksheet to be defined and added to
the export by selecting the icon.
Once the required configuration in Worksheet and Element Type Configuration has been completed as
shown and click on the Next button to continue.
84
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
Click Next button from the Column and Element Configuration wizard to continue.
The Save Configuration Changes wizard form will then be displayed. To save the configuration check the
Save Configuration check box. The Configuration Name could be Renamed if required.
85
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
Click the Finish button. The “Select Filename for export” dialogue will be displayed. Enter a Name for the
export file and click the Save button
86
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
The Excel Import and Export Tool provides a PML object (excelio) for batch processing of excel files. An
instance of this object can be created at the command line as follows:-
!e = object excelio()
import(‘<filename>’)
This will make the best guess at mapping worksheets and columns to database structures.
This should only be used where Worksheets are named to match Element Types and
Columns are named to match database attributes. All changes identified in the import file
will be applied to the database.
import(‘<filename>’,’<configname>’)
This will use the specified a configuration to import an Excel Workbook. All changes
identified in the import file will be applied to the database.
export(‘<filename>’,’<configname>’)
All methods return the following values to indicate the success of their operation :-
-1 error
0 success
1 warning
The export example in this user guide can be achieved non-graphically using the commands below :-
!e = object excelio()
!result = !e.export(‘C:\data\export.xls’,’ExportEquipmentAndNozzleConfiguration’)
87
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
Use the Excel Import tool to create the following records in Schematic database.
And using the Excel export tool, export schematic Equipment data as an Excel output and modify
the record as shown below before re-importing the data.
88
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
Chapter 7
Schematic Database elements can be created and edited using the Edit Members dialog or from the
schematic explorer context menu as described in the worked example below:
7.1 Creating and Editing Schematic Elements using Edit Member Function
This dialog can be used to efficiently create and edit multiple elements. Elements may also be deleted using
this feature.
Or right-click on an element in the Schematic Explorer and then select the Edit Members option.The
Edit Members dialog is then displayed.
Element data is displayed in a grid. The parent of the elements is displayed in the title bar
If the dialog was opened from the Schematic Explorer, the grid only displays elements that are
of the selected type that are below the current element in the database hierarchy, i.e. a filter is
automatically applied
www.aveva.com
89
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
If the current element is changed, the list of displayed elements may change to reflect this, depending on the
setting of this button on the toolbar:
Edit Member Dialog Toolbar: This is used to create, duplicate and delete elements
Move
Access the Edit members form, either by right-click on an element in the Schematic Explorer or select the
Edit Members option from the Edit menu The Edit Members dialog is then displayed.
If the dialog was opened from the Schematic Explorer, the grid only displays elements that are
of the selected type below the current element in the database hierarchy, i.e. a filter is
automatically applied.
90
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
Then select the type of element to create from the dropdown list in Edit Member dialog toolbar. The list
only elements types which are applicable for creation beneath the Element type of the CE.
Select where the new the new elements for creation, are to be placed in the list of existing items. For
example to place the new element(s) at the bottom the list, select this toolbar button:
To place the new element(s) at the top of the list in the grid, select this button
To place the new element(s) directly above the currently selected element in the list select this toolbar
button
To change the database order of element(s) on the grid, select an element by click its row and use the
Selection bottons to scroll up and down the list of items. The “Selection” buttons are only
enabled if the Database Order icon is selected.
Select the number of instances elements to be created from this dropdown list in the toolbar: In this
case select
To create the new element, select the “Create item” button . The new element(s) are then created
To delete an element, select it from the grid and then select the delete button from the Edit Members
main toolbar.
91
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
To duplicate an element:
Select the number of duplicates to be created from this dropdown list in the toolbar:
The name of a duplicate is the name of the original element prefixed with "Copy-of-". If
subsequent duplicates are made of the original element then each duplicated element is
prefixed with "Copy-([…])-of-[Element Name]", where […] is an incremental count of the number
of duplicates for that element.
Before data in the grid can be edited, the required “interaction mode” must be selected. There are three
interaction modes:
92
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
Select the required mode (Single Cell Edit), and then click on the required cell to edit its contents
Select the required mode (Bulk Cell Edit) and then double click on the required cell places so that it can be
edited in the same way as in Single Cell Edit mode.
Single click on the required cell and use standard window selection methods (e.g. left mouse click plus Ctrl
and Shift keys) to select multiple cells
Once multiple cells have been selected right click on the edited cell and Fill Down or Fill Up
The selected cells are then updated with the data contained within the first selected cell. This operation can
also be done by selecting Copy or Paste option from the sub-menu.
The edit members grid in which schematic elements and their attribute data is listed can be configured in a
numbers of ways such as:
To add or deletes the attribute columns displayed on the edit members grid. Right-click on the column
header of the grid and select the Column Setup option. The Column Setup form is then displayed.
94
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
To add a column, select Add Column option and enter the required expression or select the required
attribute which the column will be based on from the pull-down list. And then Select Ok button to save the
column setup
Select the Add Standard Attributes option if required, to add the standard attributes of the
selected element type
The Edit Member grid is then updated with the created attribute column, with cells populated with the
selected attribute data
95
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
Right click on the grid and select to the Feedback Colours option option from menu. From the feedback
colour sub-menu, select the option for the feedback colour to be changed as highlighted.
Select Reset Default Feedback Colours to restore the default settings from the sub-menu.
Filtering Elements
There are two facilities for filtering elements, accessed from the
The list of element types on the menu is restricted to those that may exist
under the current element in the database hierarchy.
To display a specific element (s) types, select the required element type from the list
the filter will be automatically applied.
96
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
Elements can be filtered so that only elements with a specific attribute value are displayed. This facility uses
a filter row which is displayed above the element grid.
Click on pick list button from the filter row, select the required value from the displayed list and
click on Ok button as shown.
97
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
Grid configurations can be saved for different combinations of element types which are displayed in the grid
as shown below;
To do this, select the Save grid Layout icon from the Edit Members toolbar as highlighted.
The dialog box is then displayed with a list of the current set of element types displayed in the grid to which
the configuration will apply to.
In the Comment textbox add comment, in this case Enter “Equipment and Pipeline Configuration”.
Users can save a number of configuration files for different combinabins of element types.
98
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
Click on the Manage grid layouts icon from the edit member toolbar in order to view all the saved
configurations for the current user:
These configurations are serialised for each user to the file system (in the user’s Local Settings
folder), and will therefore be available the next time the Edit Members functionality is used in a
subsequent session of the Schematic Model Manager application
Layout files can be deleted from this dialog using the Delete Selected Layouts function on the
dialog.
A grid and its contents as currently displayed can be exported to an Excel spreadsheet. Right-click on the
grid and select the Export to Excel option from the menu as shown.
99
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
Schematic Database elements can also be created and edited using Schematic Explorer context menu. This
feature is mainly used for creation of a single element as described in the worked example below
To create a single element, right-click on the element in the hierarchy beneath which the new element is to
be created.
For example, to create an SCEQUI element right-click on the relevant, schematic group (SCGROU)
element. If required a new SCGROU can be created as shown:
Select and right-click on the “Schematic WORL” from Schematic Explorer. The context menu is then
displayed. Select the required element type (in this case SCGROUP) from the New sub-menu.
The new element is created (SCGROU 1) without a name and is placed beneath the selected element in the
element hierarchy.
100
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
To rename an element, select the element, right-click, and select the Rename option from the menu. The
Name dialog is displayed.
Enter the preferred name e.g “EQUIPMENT_GROUP” as shown. Click the Apply button and then after click
the Dismiss button to close the form.
Alternatively newly created or existing elements can also be renamed using the Attribute form,
accessed from Schematic Explorer context menu.
To create an SCEQUI element right-click on the newly created schematic group (EQUIPMENT_GROUP)
element. Select the required element type (Schematic Equipment) from the New sub-menu
101
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
The new element is created without a name and is placed beneath the selected element in the element
hierarchy
Elements are shown in the Schematic Explorer with their TYPE and element sequence number
(SCEQUI 1) combined. The elements can be renamed if desired.
Newly created or existing elements types attributes can be edited/modified using the Attribute form,
accessed from Schematic Explorer context menu as described below:
The Attribute dialog is displayed, showing the current element (CE) attributes.
102
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
The background colours of cells indicate if the update is successfully or unsuccessfully. In this example the
update is successful
When a cell fails to be updated, or cannot be edited, then the likely reason will be displayed as
a tooltip
103
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
Using the Edit Member feature create and update schematic equipments and its attributes beneath
the Schematic Group (“EQUIPMENT_GROUP”) created in section 7.2.1, using the record below:
104
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
Chapter 8
8 Status Control
Status Control enables the user to control and report on the status of individual model objects as they
progress through their lifecycles. It can be applied to any model objects, e.g. tagged items, catalogue
components, drawings. The status levels are defined in the Lexicon module by the system administrator.
For further details, please refer to AVEVA Schematic Model Manager (Administration) TM3542
For further details on Status setup Configuration, please refer to AVEVA Schematic Model Manager
Training Guide (Administration) TM-3542
Select the Status Controller option.The Status Controller dialog is then displayed
www.aveva.com
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
105
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
Select New layout from the Status Layout pull down window. The Select Layout Columns dialog is then is
then displayed.
The schematic elements to which the status definitions apply will then be displayed, along with their status
values.
106
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
The P&ID which have been imported into the database and have not yet had their status values set are
displayed.
Select the SCDIAG elements and from the right click menu select Edit Status option
107
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
To change the status of the element(s) “A1-51-2009-1 to the next status in the lifecycle, select it in the list
and click Promote from the Status Definition toolbar or by right-clicking on the element and select
Promote option .
The Status Management form is then displayed, enter a comment if required, and click OK button button.
108
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
The statistical Report can be shown by selecting Statistical Report from the right click sub-menu. As shown
below.
109
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
1. Change the status of the listed schematic diagram in accordance with the lifecycle shown below:
110
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
Chapter 9
The Compare/Update feature is designed for use by Schematic Model Manager, Diagrams, Tags, Design,
Outfitting and Paragon.
The tool can compare and update data between Design, Schematic and Engineering databases, as well as
data from AVEVA Instrumentation and AVEVA Electrical. The integrating between two Dabacon databases
adds the capability to link objects using the linking capabilities shared with Schematic 3D Integrator.
This section covers comparison of attribute values for schematic instruments against corresponding
instruments data held in AVEVA Instrumentation, and updates of schematic database with values from
AVEVA Instrumentation.
The Compare/Update feature is accessed. By selecting Compare/Update option from the View menu. The
Compare/Update form is then displayed.
www.aveva.com
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
111
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
Compare/Update Toolbar:
Accept All – To accept or reject all available changes on all objects compared
Instrument data from AVEVA Instrumentation can be accessed and compared against the Schematic
Database.
To do this;
First select Compare/Update from the View menu. The Compare/Update Window is then displayed.
Click once on Login button from Compare/Update toolbar, to display “Select an AVEVA
Instrumentation Project” dialog
Then select the required Instrumentation project from the list of available instrumentation projects and
click Select button.
112
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
If attribute mappings have not been set up, the user will be prompted to do this. If the Yes button is
selected the Options dialog used to define the attribute mappings is then displayed.
If element filtering has not been set up, the user will be prompted to do this. If Yes button is selected
the Filter window is displayed. This is used to define one or more filters to control the selection of
instrument Tags and Loops will be compared from AVEVA Instrumentation.
This example covers comparison of attribute values for schematic instruments against corresponding
instruments data held in AVEVA Instrumentation, and updating the schematic database with values from
AVEVA Instrumentation
To do this;
Set the element type that will be compared and to map their respective attributes. By selecting the Options
tab from Compare/Update toolbar. The Options window is then displayed.
113
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
In the Group field select required Group; in this case select Instruments from the pull down list. To set the
element types with common mappings, select Instruments or loop from the Group pull down list then
check the required types in the Common attribute applied for list.
Select the Map Attributes button from Options dialog and then the Attribute Mapping window will be
displayed. This is then used to define attribute mappings for selected instrument or loop types.
114
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
To add an attribute mapping, select the “Common Instrument” from Element type field. Click on Aveva
Instrumentation Attribute and Schematic Attribute rows and from the pull down list, select a
corresponding or required attributes as shown.
New rows can also be added or deleted by selecting the required row and then select add or remove from
the right click context menu as shown:
Once all the required mappings have been set up, press the OK button to save the mappings.
When mapping attribute between “AVEVA Instrumentation” and “Schematic Model”, If multiple
mappings are entered for the same Schematic Model attribute, the last available mapping will
be the one used.
Options and attribute mappings are automatically saved in the folder: C:\Documents and
Settings\<CurrentUser>\LocalSettings\ApplicationData\Aveva\PDMS\Aveva\SchematicIns
trumentationAddin.
115
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
Once the element that will be compared and to map their respective attributes have been setup,
select the element type of the items that will be compared from the field next to the “Logoff from AVEVA
Instrumentation” icon as shown:
The compare process will start automatically, displaying a progress bar as it proceeds.
If attribute mappings have previously been set up the compare process will start automatically.
The compare process starts automatically following login to the AVEVA Instrumentation project
and selection of the element type to conduct the compare process on from the field next to the
“Logoff from AVEVA Instrumentation” icon
The results of the compare process will be displayed in the instrument grid. The Instrument Grid lists the
instruments retrieved from AVEVA Instrumentation and compared against the Schematic Database.The
Compare/Update form contains twoTabs
1. Instruments or Loops tab - lists all items compared, and also includes matched items, and changes
available for each.
116
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
2. Attribute details tab - lists the individual attribute differences for each selected instrument or loop.
Selecting one or more rows in either tab will automatically select all the corresponding rows in
the other tab and will set the current element to the first instrument or loop in the selection. And
selecting an object in either of the Compare/Update tab will automatically select the
corresponding object in the schematic Explorer, if that object is available for update in the
schematic explorer.
Only instruments data that is available in both Aveva Instrumentation and Schematic Model DB
are matched during the compare process.
The Refresh button can be used to re-read the data from Aveva Instrumentation and Schematic
Model and as well as to repeat the compare process.
117
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
Accept column - displays check boxes showing the current choice for how the compared data will be
updated.
If the check box is checked – All attributes related to this item (01-PI-
527) will be updated into the Schematic Database when the user select
UpdateDB botton from the main Compare/Update toolbar.
If the check box is Semi-checked – This means some of the attributes for this object (01-PI-525)
will be updated in the Schematic Database.
Matched Column - Cells in the matched column confirms if items in AVEVA Instrumentation database
(Source database) has matched with corresponding items in the Schematic DB (Target Database).
Matched Against column - lists the type of matching object in the Schematic DB
Examples of element types are SCOINS, SCINST, SCVALV SCACTU and SCLOOP
Wrong type: <type>: Displayed when object (s) is matched but not to an appropriate type.
118
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
No of Changes column - lists how many attribute changes are available for update
Changed Attributes column - displays a comma separated list of the attributes whose values have
changed
Attributes to be Updated column - This displays the attributes with differences in values, which have been
selected for update
Users can add more columns from the available Aveva Instrumentation attributes to the grid
using Column Setup Option.
The Update Datebase tool provides the user with the capability; to apply all the accepted changes from the
compare process result to schematic DB.
To access this functionality select the Update Datebase button from the Compare/Update main toolbar as
shown below.
Before applying changes to Schematic DB, users must first accept changes for Update. Using the following
methods to accept which attribute should be updated.
119
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
Use the Accept All check box from the Compare/Update main toolbar as shown below,
to accept or reject all available changes on all objects compared.
Use the Accept check boxes in the Instruments tab or the Attributes Details tab to accept or reject all
available changes.
Instruments tab
In the Attribute Details tab individual attribute changes for an object can also be accepted by
checking the Accept check box next to the required object.
120
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
After accepting the required changes, select the Update Datebase button to apply all the accepted changes
to the Schematic Database. The Update Schematic Model Database dialog will be displayed showing the
statistics from the compare process and the changes accepted for update.
Once the update process has completed, the results summary will be displayed. The grid will be updated
with results messages as shown.
The grid view will be updated to display any messages and errors, highlighting in the appropriate feedback
colours as shown
121
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
If an update error occurs for a particular attribute, only that attribute will fail to update. Other
attributes on the same element will still be updated.
If no attributes are updated in the schematic database the following reasons should be considered:
There is no matching object in the Schematic Database for the object in AVEVA Instrumentation. In
this case the row is greyed out.
The AVEVA Instrumentation object is matched but the Schematic Database object is not an
appropriate type, these being SCOINS, SCINST, SCVALV, SCACTU, SCLOOP or a UDET based
on one of these types.
Filtering is useful to limit the number of rows displayed in the grid. For example using AVEVA Instrumentaion
project, if a large number of Instruments and Loops are present in the project, applying the filter tool controls
which Instrument data will be compared from AVEVA Instrumentation.
If element filtering has not been set up, the user will be
prompted to do this after login.
The Filter options can also be accessed by selecting the Filter icon from the Compare/Update
main toolbar.
To setup a Filter;
Select OK to save the filter. To display the filtered attribute in the grid, select Refresh icon from
Compare/Update main toolbar
122
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
In this example only Item “01-FT-520” is displayed on the grid at the end of of the compare process.
Filters are saved to the same file and folder as the Attribute Mappings. To delete a filter, select
the row and click on the Delete Filter button.
A filter that has previously been saved will be applied to the data being read from AVEVA
Instrumentation. If the filter prevents required Instrumentation data from being displayed,
modify the Filter settings, then click Refresh in the toolbar and proceed with the compare
process.
The grid configuration menu can be accessed via a context menu by right clicking in any column title.
To display additional columns from the available AVEVA Instrumentation attributes in the grid;
123
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
Grid Settings
Right click on any column title and select Settings option to display the settings submenu. Select any of the
grid settings to enable or disable the required function by clicking on the required settings as shown below.
To set feedback colours, right click in any column title, select Settings > Feedback Colours to display the
submenu.
Then select the required options, in this case Matched with Changes Row Colour to display
the colour selector dialogue for that category
In this case select the orange colour, as shown below
And then select the Dismiss button, to close the dialog.
To revert to the default colours, select the Reset button.
124
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
To access the Instrument Datasheet or Details, select and right click in any row in the Instruments or
Loops tab to display the context menu.
Select Instrument Datasheet to view the AVEVA Instrumentation datasheet for that object.
Select Instrument Details to view the AVEVA Instrumentation dialogue for that object.
The Instrument Datasheet or Instrument Details option can also be accessed via the Schematic explorer
context menu, by right click on the required instrument.
The Instrument Datasheet or Details icon in Schematic explorer context menu is only visible
when the user is logged in to an Aveva Instrumentation database.
Grid layouts are automatically saved in the folder C:\Documents and Settings\<Current
User>\LocalSettings\ApplicationData\Aveva\PDMS\Aveva\SchematicInstrumentationAddin with
filenames of SchAiInstruments.xml and SchAiLoops.xml
125
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
1. Compare the attribute values for schematic equipments (Scequip) against corresponding equipment data
held in Design database and updating the schematic database with values from AVEVA Design.
Open the Options tab from Compare/Update toolbar and setup the required attributes mappings
that will be compared using the table below:
Once the element attribute mapping have been setup, select the element type in this case Design
Equipment from the field next to the “Source” field as shown to start the compare process.
2. Updating the schematic database with the Design Equipment values from AVEVA Design.
126
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
Chapter 10
The AVEVA Plant Schematic database stores a large amount of 2D schematic information about each
element. The user can extract this data either graphically, in the form of diagrams, or in text form, in the form
of a report. This chapter describes the principles and practice of producing reports from the Schematic
database.
The Schematic Model Manager application provides a number of pre-defined Report Templates.
The Report Designer add-in is an interactive visual report designer provided with AVEVA PDMS and AVEVA
Marine.
Report Designer enables users to create new reports, bind them to data, and pass them to another
workstation for loading into another instance of the Report Designer. In addition to report editing capabilities,
it allows the user to display print previews and to print reports and export or print reports in different format
such as PDF, HTML etc.
In Schematic Module Manager Report Designer is accessed by selecting Tools > Reporting > Run
Report or Designer from Schematic Model Manager main toolbar.
www.aveva.com
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
127
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
The resulting feature can also be accessed from the Search Utility grid right click menu as shown below;
Using Report Designer, user can edit existing reports and create new reports template. The procedures for
editing and creating reports are described in the worked example below;
First, select Tools > Reporting > Designer from the Schematic Model Manager main toolbar, the
Report Designer dialog will be displayed as shown;
128
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
Click on File > New from Report Designer main toolbar, New Report dialog is displayed as shown
below. This Dialog is used to select the layout template (a .repx file format) to be used as the basis for
the new report.
The New Report Dialog can also display by selecting button from Report Designer Main
Toolbar. If there is another report already loaded in the Designer, then the user is asked
whether this report should be saved before it is replaced with the new one.
Click on the Look In drop-down to select the template layout location, in this example select “Product” as
shown
Product: %PDMSDFLTS%\Data\Reports
Project: %<PRJ>INFO%\Reports
User: %PDMSUSER%\Data\Reports
Browse… to look for layout templates in an alternative folder.
129
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
Once a folder has been selected, the layout templates in that folder are listed in the Layout Template tab.
Click on a template to view a preview of it. As shown;
Then click on Create button from New Report Dialog to select a template and exit the window. A new report
layout is then created based on the selected template and displayed in the Designer tab as shown below;
For further details on changing page settings, border widths for a report, please refer to
Reporting User Guide.
130
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
10.2.2 Bind Report Layout Template to Dabacon Project Data – Worked Example
Once a report layout has been created, project data can be bind to the layout template using Data Source
Wizard as described below.
In this worked example, bind the Report layout template created in worked example in Section 10.2.1 to
Equipment (SCEQUIP) data in Schematic Database project database using Data Source Wizard form.
To do this;
Click Data Source from Report Designer main toolbar, Data Source Wizard dialog is displayed as shown
below.
Use Edit to modify the data source of the current report (this option is not available if the
current report does not have a data source defined for it)
131
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
Click Next button from the Properties dialog. The Base Element Types dialog of the wizard is then
displayed. Select prefered element type (in this case SCEQUIP), as the base element type for the report.
The list of elements shown may be filtered by typing in the filter box as shown
132
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
Select the prefered element type in this case SCEQUIP by clicking on them and use the arrow buttons to
move the selected elements for the data source to the Base Element Types section as shown below.
Click Next button from the Base Element Types dialog. The Filters dialog of the wizard is then displayed.
133
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
To add a new filter click on Add Filter button, select the required attribute (in this case “Name”) to apply the
filter to and select the appropriate “Operator” which is this case “Contains”. Then enter the required
Operator “Value” (in this case “/P”) as shown below.
Click Next button from the Filter dialog. The Columns form of the wizard is then displayed.
134
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
To add attribute column to the Data Source Columns pane, which will be included in the report, click on the
preferred attributes and use the arrow buttons highlighted below to move the selected columns to the Data
Source Columns box as shown below.
Click Finish button when the data source definition is complete. The data source is then saved inside the
report and the Field List on the right-hand side will display the attributes selected in the Data Source wizard
as shown:
The data source may be edited by selecting Edit option of the Data Source Wizard
135
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
Select Equip List from Field List, Drag and drop the desired attributes to the Detail section in the report. As
shown below.
136
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
Use the Standard Control functions to add Page Header, Report Header and Company Logo if required as
shown:
Click Preview tab to see a preview of current layout with the first 20 records available from the associated
data source:
137
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
Click on Run Report as shown below to run the report definition with the actual data available from the bind
data source.
Select the Watermark Icon from the Run Report dialog to insert ghosted text as shown, if required.
The report can be saved, export or print in different format such as shown.
For further details, on Report styles, conditional formatting and types please refer to Reporting User
Guide.
138
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
Click on Save button from Report Designer main toolbar as highlighted below or menu option to save the
current report definition as a report definition or report layout.
Enter appropriate File name, in this case enter “Equipment List” as shown and Click on Save button to save
the file.
139
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
Reports can also be generated by opening an existing report or layout template, the procedures are
described in the worked example below;
In this worked example, run a report based on existing Equipment list Report Layout created in Example 1
above, modify the layout and save it as a new report.
To do this;
Select Tools > Reporting > Run Report from Schematic Model Manager main toolbar, the Run Report
dialog will be displayed as shown below;
Select the appropriate location in this case (User directory) from the Look In pull down window to display
saved Report Definitions as shown
140
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
Then click on Run button from the Run Dialog to run the report based on the selected Report template
141
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
The standard Search feature can be used to configure a search which returns, in a grid, the attributes
required to generate Line list , Equipment List etc.
To access the Search Utility, if not already open, select Search from the View menu.
Schematic Model Manager Searches can be accessed by opening the saved Searches section at the
bottom of the Search utility
Then select the Database type (Schematic) the search will be applied to from the Search filter section on the
Search Utility.
142
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
Any of the searches can be run by using the next dropdown list to select the required search in this case
Line List-SCPLIN
Users can setup additional configuration rules if required for SCPLINE and SCBRANCH to
specify the following; elements to be included in the line list, to generate the text displayed in
the line list for the From and To attributes, and how diagram names are displayed in the line list.
For further please refer to AVEVA Schematic Model Manager Training Guide
(Administration) TM-3542
143
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
Right-click on a column heading, and from the right click menu that is then displayed, select Column
Setup… and add desired attribute columns.
The Column Setup dialog is then displayed. Enter the following columns as shown below and then press
the OK button.
The Search Results grid will be automatically populated with the set attribute values.
144
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
Right-click on a column heading, and from the right-click menu that is then displayed, select Export
to Excel...
A Save As dialog will then be displayed. Enter meaningful name for the exported line list, in this
example "LineList" is used.
The saved search results will then be exported as an Excel spreadsheet file.
The file will contain your line list data, including your defined column headings, and some default formatting.
145
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
10.2.5 Running Quick report From Search Result Grid – Worked Example
The results of a search may be sent from the Search Results grid to the reporting tool for formatting.
To use the Quick Reports feature, activate the right-click menu available from any column heading in the
Search Results grid, and select Quick Report.
If you have already designed a layout template for use with this Saved Search, then select that Layout
Template. And if any of the default layout is selected you will then be prompted to confirm if you want to
default layout to be applied as shown below:
146
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
If Yes’ button is selected, the Reporting Tool will automatically place the fields in your Search Results grid
into a system generated table placed directly in your Quick Report and displayed in Preview Tab. as shown
below.
Select this option when the search results grid contains a small number of fields
The Preview shown in a Quick Report includes all data supplied by the Search Results grid. Data Source,
Scope and Run buttons are disabled in a Quick Report preview. Data source is not required as the source of
data for a Quick Report as this is achieved from the ‘Search Results Grid’.
If you are using a Saved Search and have selected a Layout Template, which you have already
designed for use with the Search, then do not select ‘Yes’ button, as the Default Layout will
overwrite your Layout Template.
147
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
Exercise 8 - Reporting
1. Using the Quick Report functionality, run a report from search result generated from schematic pipeline
2. Save the report in pdf file format.
148
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
Chapter 9
11 Troubleshooting
AVEVA Schematic Model Manager has some known limitations at this time and in this next section we will
discuss some of these and some of the error messages.
11.1 Overview
The XML files for importing will contain engineering items and graphical data. There is a validation check on
XML files prior to importing so these must be consistent and comply with the ISO 15926 schema definition.
If on import a file is found to be invalid, an error message is displayed, listing the invalid file. The error must
be corrected for this file to be imported; there is no partial import option.
XML files are validated prior to Import to confirm that they comply with the AVEVA ISO 15926 shema.
Invalid XML files are identified and are not imported. Error messages will indicate the type of problem
encountered but not exactly where the problem is. Investigation of the xml file is sometimes necessary to
locate the problem. Any issues must be resolved in the source application for the import process to proceed
with the invalid file.
In the following example an attempt is made to import an invalid xml file. The application identifies that this
file is invalid due to the polyline element having incomplete content and it indicates that ‘Coordinate’ is
expected but not found.
Investigation of the xml file using Notepad reveals that a polyline element should have a description like this,
<PolyLine NumPoints="2">
<Presentation Layer="0" LineType="Solid" LineWeight="0.5" Color="White" R="1" G="1" B="1" />
<Extent>
<Min X="368" Y="380" Z="0"/>
<Max X="372" Y="380" Z="0"/>
</Extent>
<Coordinate X="372" Y="380" Z="0"/>
<Coordinate X="368" Y="380" Z="0"/>
</PolyLine>
Use the Notepad Find option to locate the first occurance of “Polyline”. Then find the Polyline bounding tags
(shown in blue font) for that Polyline element.
From the text above we can see that the content includes information about the polyline presentation, layer,
color etc, and information about the polyline graphics, including 2 coordinate lines. Now all we have to do is
locate all polyline elements that have no coordinate content.
www.aveva.com
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
149
All rights reserved.
AVEVA Plant (12.1)
Schematic Model Manager TM-3541
Using the Notepad Find option, locate every occurrence of </PolyLine> looking for missing coordinate lines.
Eventually the following polyline should be located with missing coordinates,
<PolyLine >
<Presentation Layer="AS_EQU" LineType="Solid" LineWeight="0.5" Color="92" R="0" G="0.8"
B="0" />
<Extent>
<Min X="477" Y="274" Z="0"/>
<Max X="505.09" Y="287" Z="0"/>
</Extent>
</PolyLine>
Using the coordinates we can now locate the polyline on the P&ID. In this instance the problem is due to the
shell ends on the heat exchanger symbol being an unsupported entity (curved polyline).
Once all the problems are fixed on the source P&ID the subsequent xml output file can then be imported into
Schematic Model Manager.
Look out for incomplete content as above caused by using unsupported entities, foreign language
characters in xml file, and incorrect format of values (text value instead of numerical) or incomplete item
descriptions.
Some Process link arrangements in Aveva P&ID are not currently supported
Entities (Acad) not supported by the XML schema:Splines, curve polylines, linetypes other than the 6
supported by xmplant, shapes, filled entites, hatch, Unicode fonts, big fonts, ellipses that have been
scale up or down
HVAC or Electrical item Import is not currently supported
Element names (pre 12.0.0.2 are raw tag values and are not configurable)
Units of measure is a fixed unit for each measured type
150
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
Appendix A
Appendix A
Listed below is a sample list of ISO 15926 Item Types and the associated GTYPE / SCTYPE values.
152
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
All rights reserved.
Appendix D
Appendix B
GTYPE - a word attribute indicating the generic type of the PDMS Piping Component, selected from the
following list. Selected choice should consider 3D activities and output.
For more information please refer to the PDMS 12 Isodraft Admin Guide.
ATTA attachment
BEND pipe bend
CAP end cap
CLOS closure
COUP coupling
CROS cross piece
DUCT ducting
ELBO fitting elbow
FBLI blind flange
FILT filter
FLAN or FLG flange
FTUB fixed length tube
GASK gasket
HELE hanger element
INST instrument
INSU insulation
LJSE lap joint stub end
NOZZ nozzle
OLET weldolets
PCOM pipe component
REDU reducer
SHU standard hook-up
TEE fitting tee
TRAC tracing
TRAP steam trap
TUBE implied tube
UNIO union
VALV valve
VENT open-ended pipe or vent
VFWA four-way valve
VTWA three-way valve
WELD weld
www.aveva.com
© Copyright 1974 to current year.
AVEVA Solutions Limited and its subsidiaries.
153