Project name CAPILLA HUANDOY


Project address Peru
Reference LIMA
Client name ASPERSUD
Revision GCM_06

Selection parameters of the indoor units can be found under the chapter Indoor unit details
Selection parameters of the outdoor units can be found under the chapter Outdoor unit details
Only the data published in the data book are correct. This program uses close approximations of these data.

1. Material List
Model Qty Description
RHXYQ14ATL 1 Heat pump VRV IV 220V(TL)
RHXYQ22ATL 4 Heat pump VRV IV 220V(TL)
FXAQ20PVE 4 VRV AP - De Pared (Panel Plano)
FXAQ32PVE 6 VRV AP - De Pared (Panel Plano)
FXMQ100PAVE 1 VRV M-PA - Unidad de conducto montada en el techo
FXMQ140PAVE 1 VRV M-PA - Unidad de conducto montada en el techo
FXMQ250MAVE 8 VRV M-A - Unidad de conducto montada en el techo
FXMQ50PAVE 1 VRV M-PA - Unidad de conducto montada en el techo
FXMQ63PAVE 1 VRV M-PA - Unidad de conducto montada en el techo
KHRP26A22T 9 Refnet branch piping kit
KHRP26A33T 1 Refnet branch piping kit
KHRP26A72T 5 Refnet branch piping kit
KHRP26A73T + KHRP26M73TP 4 Refnet branch piping kit
BRC1E62 21 Wired Remote Controller (Navigation Remote Controller)
BRC1E63 1 Wired Remote Controller (Navigation Remote Controller)
BHFP22P100 2 Outdoor unit multi connection piping kit
R410A 68.1kg Extra refrigerant charge
Piping ¼" 57.3m
Piping ⅜" 102.2m
Piping ½" 147.4m
Piping ⅝" 55.6m
Piping ¾" 124.2m
Piping ⅞" 84.3m
Piping 1" 23.2m
Piping 1⅛" 17.9m
Piping 1¼" 11.7m
Piping 1½" 84.0m

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Page 1
2. Indoor Unit Details
2.1. Table of Abbreviations
Name Logical name of the device
FCU Device model name
Tmp C Indoor conditions in cooling (dry bulb temp. / wet bulb temp.)
Rq TC Required total cooling capacity
Max TC Available total cooling capacity
Rq SC Required sensible cooling capacity
Max SC Available sensible cooling capacity
Tevap Evaporating temperature of indoor unit coil
Tdis C Indoor unit discharge air temperature in cooling
Tmp H Indoor temperature in heating
Rq HC Required heating capacity
Max HC Available heating capacity
Tdis H Indoor unit discharge air temperature in heating
Airflow Supplied airflow
Sound Sound pressure low and high
PS Power supply (voltage and phases)
MCA Minimum Circuit Amps
WxHxD WidthxHeightxDepth
Wght Weight of the device

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Page 2
2.2. VRV - 2 - RHXYQ14ATL
Capacity data at conditions and connection ratio (109%) as entered
Name FCU Tmp C Rq TC Max TC Rq SC Max SC Tevap Tdis C Tmp H Rq HC Max HC Tdis H Airflow
°C BTU/h BTU/h BTU/h BTU/h °C °C °C BTU/h BTU/h °C cfm
UE - 1 FXAQ32PVE 24.0 / 17.0 n/a 10748 n/a 8087 6.0 10.4 20.0 n/a 13649 43.0 300
UE - 2 FXAQ20PVE 24.0 / 17.0 n/a 6654 n/a 5903 6.0 12.7 20.0 n/a 8530 36.3 265
UE - 3 FXAQ20PVE 24.0 / 17.0 n/a 6654 n/a 5903 6.0 12.7 20.0 n/a 8530 36.3 265
UE - 4 FXAQ32PVE 24.0 / 17.0 n/a 10748 n/a 8087 6.0 10.4 20.0 n/a 13649 43.0 300
UE - 5 FXMQ50PAVE 24.0 / 17.0 n/a 16549 n/a 14133 6.0 12.8 20.0 n/a 21496 37.1 636
UE - 6 FXAQ32PVE 24.0 / 17.0 n/a 10748 n/a 8087 6.0 10.4 20.0 n/a 13649 43.0 300
UE - 7 FXAQ20PVE 24.0 / 17.0 n/a 6654 n/a 5903 6.0 12.7 20.0 n/a 8530 36.3 265
UE - 8 FXAQ20PVE 24.0 / 17.0 n/a 6654 n/a 5903 6.0 12.7 20.0 n/a 8530 36.3 265
UE - 9 FXAQ32PVE 24.0 / 17.0 n/a 10748 n/a 8087 6.0 10.4 20.0 n/a 13649 43.0 300
UE - 10 FXAQ32PVE 24.0 / 17.0 n/a 10748 n/a 8087 6.0 10.4 20.0 n/a 13649 43.0 300
UE - 11 FXAQ32PVE 24.0 / 17.0 n/a 10748 n/a 8087 6.0 10.4 20.0 n/a 13649 43.0 300
UE - 12 FXMQ63PAVE 24.0 / 17.0 n/a 20985 n/a 16962 6.0 11.6 20.0 n/a 27297 40.0 689

Required cooling capacity towards the outdoor unit: 128638BTU/h.


Required heating capacity towards the outdoor unit: 164806BTU/h.

The calculation shows the peak discharge temperatures (lowest temperature in case of cooling mode / highest
temperature in case of heating mode), assuming the indoor unit is running at full load at the given indoor
temperature design conditions. In practice the discharge temperature will modulate based on actual capacity
requirements and during defrost mode (heating mode).
The analysis of the suction and discharge temperature values may help in preventing a cold draft and to ensure a
thermal comfort level.

Name Sound PS MCA WxHxD Wght


dBA A mm kg
UE - 1 31-38 220V 1ph 0.4 795×290×238 11
UE - 2 31-35 220V 1ph 0.3 795×290×238 11
UE - 3 31-35 220V 1ph 0.3 795×290×238 11
UE - 4 31-38 220V 1ph 0.4 795×290×238 11
UE - 5 37-41 220V 1ph 1.6 1000×300×700 35
UE - 6 31-38 220V 1ph 0.4 795×290×238 11
UE - 7 31-35 220V 1ph 0.3 795×290×238 11
UE - 8 31-35 220V 1ph 0.3 795×290×238 11
UE - 9 31-38 220V 1ph 0.4 795×290×238 11
UE - 10 31-38 220V 1ph 0.4 795×290×238 11
UE - 11 31-38 220V 1ph 0.4 795×290×238 11
UE - 12 38-42 220V 1ph 1.8 1000×300×700 35

Outdoor unit placed at the same level as the indoor units.

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Page 3
2.3. VRV - 3 - RHXYQ44ATL
Capacity data at conditions and connection ratio (100%) as entered
Name FCU Tmp C Rq TC Max TC Rq SC Max SC Tevap Tdis C Tmp H Rq HC Max HC Tdis H Airflow
°C BTU/h BTU/h BTU/h BTU/h °C °C °C BTU/h BTU/h °C cfm
UE - 13 FXMQ100PAVE 24.0 / 17.0 n/a 33269 n/a 25714 6.0 12.5 20.0 n/a 42652 39.1 1130
UE - 14 FXMQ250MAVE 24.0 / 17.0 n/a 83086 n/a 64182 6.0 11.3 20.0 n/a 107482 41.3 2543
UE - 15 FXMQ250MAVE 24.0 / 17.0 n/a 83086 n/a 64182 6.0 11.3 20.0 n/a 107482 41.3 2543
UE - 16 FXMQ250MAVE 24.0 / 17.0 n/a 83086 n/a 64182 6.0 11.3 20.0 n/a 107482 41.3 2543
UE - 17 FXMQ250MAVE 24.0 / 17.0 n/a 83086 n/a 64182 6.0 11.3 20.0 n/a 107482 41.3 2543

Required cooling capacity towards the outdoor unit: 365613BTU/h.


Required heating capacity towards the outdoor unit: 472582BTU/h.

The calculation shows the peak discharge temperatures (lowest temperature in case of cooling mode / highest
temperature in case of heating mode), assuming the indoor unit is running at full load at the given indoor
temperature design conditions. In practice the discharge temperature will modulate based on actual capacity
requirements and during defrost mode (heating mode).
The analysis of the suction and discharge temperature values may help in preventing a cold draft and to ensure a
thermal comfort level.

Name Sound PS MCA WxHxD Wght


dBA A mm kg
UE - 13 39-43 220V 1ph 2.9 1400×300×700 45
UE - 14 45.5-48.5 220V 1ph 10.1 1380×470×1100 137
UE - 15 45.5-48.5 220V 1ph 10.1 1380×470×1100 137
UE - 16 45.5-48.5 220V 1ph 10.1 1380×470×1100 137
UE - 17 45.5-48.5 220V 1ph 10.1 1380×470×1100 137

Outdoor unit placed at the same level as the indoor units.

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Page 4
2.4. VRV - 4 - RHXYQ44ATL
Capacity data at conditions and connection ratio (104%) as entered
Name FCU Tmp C Rq TC Max TC Rq SC Max SC Tevap Tdis C Tmp H Rq HC Max HC Tdis H Airflow
°C BTU/h BTU/h BTU/h BTU/h °C °C °C BTU/h BTU/h °C cfm
UE - 18 FXMQ250MAVE 24.0 / 17.0 n/a 83086 n/a 64182 6.0 11.3 20.0 n/a 107482 41.3 2543
UE - 19 FXMQ250MAVE 24.0 / 17.0 n/a 83086 n/a 64182 6.0 11.3 20.0 n/a 107482 41.3 2543
UE - 20 FXMQ250MAVE 24.0 / 17.0 n/a 83086 n/a 64182 6.0 11.3 20.0 n/a 107482 41.3 2543
UE - 21 FXMQ250MAVE 24.0 / 17.0 n/a 83086 n/a 64182 6.0 11.3 20.0 n/a 107482 41.3 2543
UE - 22 FXMQ140PAVE 24.0 / 17.0 n/a 47600 n/a 36455 6.0 12.7 20.0 n/a 61419 39.1 1624

Required cooling capacity towards the outdoor unit: 379944BTU/h.


Required heating capacity towards the outdoor unit: 491349BTU/h.

The calculation shows the peak discharge temperatures (lowest temperature in case of cooling mode / highest
temperature in case of heating mode), assuming the indoor unit is running at full load at the given indoor
temperature design conditions. In practice the discharge temperature will modulate based on actual capacity
requirements and during defrost mode (heating mode).
The analysis of the suction and discharge temperature values may help in preventing a cold draft and to ensure a
thermal comfort level.

Name Sound PS MCA WxHxD Wght


dBA A mm kg
UE - 18 45.5-48.5 220V 1ph 10.1 1380×470×1100 137
UE - 19 45.5-48.5 220V 1ph 10.1 1380×470×1100 137
UE - 20 45.5-48.5 220V 1ph 10.1 1380×470×1100 137
UE - 21 45.5-48.5 220V 1ph 10.1 1380×470×1100 137
UE - 22 43-46 220V 1ph 3.4 1400×300×700 46

Outdoor unit placed at the same level as the indoor units.

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Page 5
3. Outdoor Unit Details
3.1. Table of Abbreviations
Name Logical name of the device
Model Device model name
▼ Optimized selection: Smaller outdoor model selected than standard proposed model
Tmp C Outdoor temperature in cooling
CC Available cooling capacity
Rq CC Required cooling capacity
Tmp H Outdoor conditions in heating (dry bulb temp. / wet bulb temp.)
HC Available heating capacity (integrated heating capacity)
Rq HC Required heating capacity
Piping Largest distance from indoor unit to outdoor unit
Bse Refr Standard factory refrigerant charge (5m actual piping length)
excluding extra refrigerant charge
For calculation of extra refrigerant charge refer to the databook
Ex Refr Extra refrigerant charge
PS Power supply (voltage and phases)
MCA Minimum Circuit Amps
WxHxD WidthxHeightxDepth
Wght Weight of the device

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Page 6
3.2. Outdoor Details
Name Model Comb Tmp C CC Rq CC Tmp H HC Rq HC
% °C BTU/h BTU/h °C BTU/h BTU/h
VRV - 2 RHXYQ14ATL ▼ 109 30.0 115603 (-10.1%) 128638 17.0 / 11.0 162228 (-1.6%) 164806
VRV - 3 RHXYQ44ATL ▼ 100 30.0 303955 (-16.9%) 365613 17.0 / 11.0 460356 (-2.6%) 472582
VRV - 4 RHXYQ44ATL ▼ 104 30.0 302297 (-20.4%) 379944 17.0 / 11.0 470763 (-4.2%) 491349

Name Model Piping Refrigerant


m Type Bse Refr Ex Refr
kg kg
VRV - 2 RHXYQ14ATL 65.8 R410A 6.9 15.1
VRV - 3 RHXYQ44ATL 63.6 R410A 17.2 24.7
VRV - 4 RHXYQ44ATL 86.7 R410A 17.2 28.3

Name Model PS MCA WxHxD Wght


A mm kg
VRV - 2 RHXYQ14ATL 220V 3ph 55 1240×1657×765 285
VRV - 3 RHXYQ44ATL 220V 3ph
× RHXYQ22ATL 76 1240×1657×765 317
× RHXYQ22ATL 76 1240×1657×765 317
VRV - 4 RHXYQ44ATL 220V 3ph
× RHXYQ22ATL 76 1240×1657×765 317
× RHXYQ22ATL 76 1240×1657×765 317

Sufficient distance should be respected between the modules according to the service & operation space rules as
mentioned in the databook.

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Page 7
4. Piping Diagrams
Pipes marked with * in the diagrams must be connected to the device with a reducing joint.

4.1. Piping VRV - 2


VRV - 2
RHXYQ14ATL

20.0m 21.0m 2.5m


½"×1" ½"×⅞" ¼"×½"
KHRP26A72T KHRP26A22T

UE - 1
FXAQ32PVE
2.2m 3.9m
½"×¾" ¼"×½"
KHRP26A22T

UE - 2
FXAQ20PVE
2.6m 3.8m
½"×¾" ¼"×½"
KHRP26A22T

UE - 3
FXAQ20PVE
1.7m 3.7m
½"×¾" ¼"×½"
KHRP26A22T

UE - 4
FXAQ32PVE
14.6m
¼"×½"

UE - 5
FXMQ50PAVE
3.2m 4.8m
½"×1" ¼"×½"
KHRP26A33T

UE - 6
FXAQ32PVE
2.5m 4.3m
½"×⅞" ¼"×½"
KHRP26A22T

UE - 7
FXAQ20PVE
2.2m 4.5m
½"×⅞" ¼"×½"
KHRP26A22T

UE - 8
FXAQ20PVE
3.4m 4.5m
½"×⅞" ¼"×½"
KHRP26A22T

UE - 9
FXAQ32PVE
15.0m 8.5m
½"×¾" ¼"×½"
KHRP26A22T

UE - 10
FXAQ32PVE
7.0m 2.2m
½"×¾" ¼"×½"
KHRP26A22T

UE - 11
FXAQ32PVE
9.0m
⅜"×⅝"

UE - 12
FXMQ63PAVE

The actual length (42.1m) from the first branch to UE - 5 exceeds 40.0m. The intermediate pipes are sized up
The actual length (42.3m) from the first branch to UE - 12 exceeds 40.0m. The intermediate pipes are sized up
The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Page 8
4.2. Piping VRV - 3
VRV - 3
RHXYQ44ATL
RHXYQ22ATL RHXYQ22ATL

⅝"×1⅛" ⅝"×1⅛"

BHFP22P100

38.0m 3.8m 8.0m


¾"×1½" ⅝"×1⅛" ⅜"×⅞"
KHRP26A73T + KHRP26A72T
KHRP26M73TP
UE - 15
FXMQ250MAVE
6.3m 8.7m
½"×1⅛" ⅜"×⅞"
KHRP26A72T

UE - 14
FXMQ250MAVE
14.0m
⅜"×⅝"

UE - 13
FXMQ100PAVE
4.8m 7.0m
⅝"×1⅛" ⅜"×⅞"
KHRP26A72T

UE - 16
FXMQ250MAVE
5.5m
⅜"×⅞"

UE - 17
FXMQ250MAVE

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Page 9
4.3. Piping VRV - 4
VRV - 4
RHXYQ44ATL
RHXYQ22ATL RHXYQ22ATL

⅝"×1⅛" ⅝"×1⅛"

BHFP22P100

46.0m 6.0m
¾"×1½" ⅜"×⅞"
KHRP26A73T +
KHRP26M73TP
UE - 18
FXMQ250MAVE
5.5m 6.0m
¾"×1¼" ⅜"×⅞"
KHRP26A73T +
KHRP26M73TP
UE - 19
FXMQ250MAVE
6.2m 6.0m
¾"×1¼" ⅜"×⅞"
KHRP26A73T +
KHRP26M73TP
UE - 20
FXMQ250MAVE
3.0m 8.0m
½"×1⅛" ⅜"×⅞"
KHRP26A72T

UE - 21
FXMQ250MAVE
24.0m
⅜"×⅝"

UE - 22
FXMQ140PAVE

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Page 10
5. Wiring Diagrams
P1P2 = Please select the cable type and size in accordance with the databook.
F1F2 = Please select the cable type and size in accordance with the databook.

5.1. Wiring VRV - 2


P1,P2
VRV - 2 UE - 1 BRC1E62
RHXYQ14ATL FXAQ32PVE
IN F1,F2 F1,F2 L, N 0.4A 1ph

L1,L2,L3 55A 3ph


P1,P2
UE - 2 BRC1E62
FXAQ20PVE
F1,F2 L, N 0.3A 1ph

P1,P2
UE - 3 BRC1E62
FXAQ20PVE
F1,F2 L, N 0.3A 1ph

P1,P2
UE - 4 BRC1E62
FXAQ32PVE
F1,F2 L, N 0.4A 1ph

P1,P2
UE - 5 BRC1E63
FXMQ50PAVE
F1,F2 L, N 1.6A 1ph

P1,P2
UE - 6 BRC1E62
FXAQ32PVE
F1,F2 L, N 0.4A 1ph

P1,P2
UE - 7 BRC1E62
FXAQ20PVE
F1,F2 L, N 0.3A 1ph

P1,P2
UE - 8 BRC1E62
FXAQ20PVE
F1,F2 L, N 0.3A 1ph

P1,P2
UE - 9 BRC1E62
FXAQ32PVE
F1,F2 L, N 0.4A 1ph

P1,P2
UE - 10 BRC1E62
FXAQ32PVE
F1,F2 L, N 0.4A 1ph

P1,P2
UE - 11 BRC1E62
FXAQ32PVE
F1,F2 L, N 0.4A 1ph

P1,P2
UE - 12 BRC1E62
FXMQ63PAVE
F1,F2 L, N 1.8A 1ph

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Page 11
5.2. Wiring VRV - 3
P1,P2
VRV - 3 UE - 15 BRC1E62
RHXYQ44ATL FXMQ250MAVE
IN F1,F2 F1,F2 L, N 10.1A 1ph
RHXYQ22ATL
Q1,Q2 L1,L2,L3 P1,P2
UE - 14 BRC1E62
76A 3ph
FXMQ250MAVE
RHXYQ22ATL F1,F2 L, N 10.1A 1ph
Q1,Q2 L1,L2,L3
76A 3ph P1,P2
UE - 13 BRC1E62
FXMQ100PAVE
F1,F2 L, N 2.9A 1ph

P1,P2
UE - 16 BRC1E62
FXMQ250MAVE
F1,F2 L, N 10.1A 1ph

P1,P2
UE - 17 BRC1E62
FXMQ250MAVE
F1,F2 L, N 10.1A 1ph

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Page 12
5.3. Wiring VRV - 4
P1,P2
VRV - 4 UE - 18 BRC1E62
RHXYQ44ATL FXMQ250MAVE
IN F1,F2 F1,F2 L, N 10.1A 1ph
RHXYQ22ATL
Q1,Q2 L1,L2,L3 P1,P2
UE - 19 BRC1E62
76A 3ph
FXMQ250MAVE
RHXYQ22ATL F1,F2 L, N 10.1A 1ph
Q1,Q2 L1,L2,L3
76A 3ph P1,P2
UE - 20 BRC1E62
FXMQ250MAVE
F1,F2 L, N 10.1A 1ph

P1,P2
UE - 21 BRC1E62
FXMQ250MAVE
F1,F2 L, N 10.1A 1ph

P1,P2
UE - 22 BRC1E62
FXMQ140PAVE
F1,F2 L, N 3.4A 1ph

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Page 13
6. Device Options
6.1. Outdoor Unit Options
Model Description Used by
BHFP22P100 Outdoor unit multi connection piping kit VRV - 3 [RHXYQ44ATL] VRV - 4 [RHXYQ44ATL]

The Xpress Selection Program is property of Daikin Europe NV. Daikin Europe NV cannot be held liable for any inaccuracy, reliability of the outcome of the Xpress Selection
Program.

Page 14

You might also like