DET-5306-074

Power Charge Electric Igniter


TECHNICAL
SPECIFICATIONS:
APPLICATION:

BKNO3 based Power Charge Electric Igniter Assembly Part Number: DET-5306-074
Igniter. Used in wireline operations to
initiate power charge products with a D.O.T. EX Number: EX2008120360
99.99% initiation reliability @ 95% Shipping Class: 1.4S
confidence level.
CE Number: 0080.EXP.01.0024
RATINGS: UN Number: UN0454
TEMPERATURE RATING:

400°F (200°C) for 1 hour

ELECTRICAL SPECIFICATIONS:

RESISTANCE:

51.0Ω
ALL-FIRE LEVEL:
1.0 Amp
NO-FIRE LEVEL:
0.2 Amps for 5 min.
STATIC SENSITIVITY:
MIL-DTL-23659F IMPORTANT NOTES:

This Igniter is compatible with all Owen Power Charge products. Please refer
EXPLOSIVES: to User Manual MAN-DET-074 for further details on use of this igniter.
BASE CHARGE:

2.7 grams (BKNO3)


PRIMARY EXPLOSIVE:

None

PACKAGING:

QUANTITY PER BOX:


10 (can be packed up to 50)
NET EXPLOSIVE WEIGHT:
27 grams
NET ITEM WEIGHT:
13.6 grams (0.03 lbs)
TOTAL PACKAGE WEIGHT:
2 lbs This igniter is designed to initiate Power Charge products and not high
BOX DIMENSIONS:
explosives. This is a "wireless" igniter design that utilizes the spring as
13.4 in. X 6.7 in. X 6.9 in. the postive terminal and the brass body as the negative (ground)
terminal by making contact with the metal hardware. For best results,
SHELF LIFE:
ensure the hardware is clean of any debris or residue so that a proper
5 years from DOM (in original packaging) grounding connection can be made.
PACKAGE TYPE:
4G fiberboard box

DET-5306-074-DS (R01)