Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

N-600x™ Pulse Oximeter

Confidently Monitor Your


Most Critically Ill Patients

EXTREME PERFORMANCE DEFINED EASY TO SEE, EASY TO USE


™ ™ ™
The NELLCOR OXIMAX N-600x
• Bright blue backlight with dimmer
LOSAT™ EXPANDED ACCURACY pulse oximeter delivers exceptional
and contrast adjustment.
The LOSAT™ expanded accuracy feature
performance throughout the hospital,
of our OxiMax adhesive sensors assures • Flip feet let you adjust the angle for
so you can confidently monitor even
you of the industry’s widest accuracy improved tabletop viewing.
your most critically ill patients. While
range (60% to 100% SpO2) when used
with the OxiMax N-600x pulse oximeter. some oximeters may have trouble • Three display options: plethysmo-
This allows improved patient assessment acquiring a pulse signal during low graphic waveform, large numerics
at the more challenging lower saturation perfusion and signal interference, and customizable real-time trend.
levels common in congenital heart the OxiMax N-600x pulse oximeter
PATIENT SAFETY FEATURES
disease (CHD) infants. achieves accurate, reliable readings
during these difficult conditions. It • Digital signal processing technology
includes our unique SATSECONDS™ enhances performance during
alarm management technology to difficult conditions.*
safely reduce nuisance alarms that • SatSeconds alarm management
can interfere with staff productivity. function offers a safe, practical way
to reduce nuisance alarms.

• Connect OxiMax N-600x pulse


oximeters to Covidien’s remote
oximetry alarm systems or nurse
call systems for enhanced patient
safety on general care floors.
* The OxiMax N-600x pulse oximeter has the same signal processing
technology as the OxiMax N-600 pulse oximeter.
OXIMAX N-600X PULSE OXIMETER
Exceptional performance in any clinical • Variable pitch beep tone enables
environment and compatible with the clinicians to hear point-by-point
complete line of OxiMax sensors. changes in SpO2.

• Convenient selection of adult or • User-selectable fast-averaging mode


neonate alarm limits, and user- (2–3 seconds) to more precisely track
configurable power-on settings. rapidly changing saturations.

• On-screen quick guide provides • On-screen viewing of 24–48 hours


instant help to assist caregivers with of downloadable SpO2 and pulse rate
monitor operation. trends taken at 2–4 second intervals;
printing capability.
• Sensor Messages function provides
troubleshooting tips for optimal • Compatible with Philips VueLink
sensor application. device interface module, M1032A-A05.

OXIMAX SENSOR ADVANTAGE


The diverse family of Nellcor OxiMax sensors
expands your monitoring capabilities.

• The MAX-FAST™ forehead sensor offers a better


option for monitoring patients with low perfusion.

• SOFTCARE™ nonadhesive sensors provide a


gentle alternative for patients with fragile skin.
FEATURES AND SPECIFICATIONS
PERFORMANCE PHYSICAL CHARACTERISTICS Alarms
Measurement Range Weight Audible and visual alarms for high/low
SpO2: 1% to 100% 5.7 lb (2.6 kg) saturation and pulse rate.
Pulse rate: 20 to 250 beats per minute
Size SatSeconds alarm management settings:
Perfusion index: 0.03% to 20%
3.3 in H x 10.4 in W x 6.8 in D 10, 25, 50 and 100, or OFF
Accuracy (Adult - Neonate) (8.4 cm x 26.4 cm x 17.3 cm)
Audible and visual warning indicators
Saturation (% SpO2 ± 1 SD)
Equipment Classification for low battery.
70% to 100% ± 2 digits
• IEC 60601-1 • EN865
60% to 80% ± 3 digits Audible sensor disconnect alarm and
• CSA 601.1 • IPX1
Low perfusion: 70% to 100% ± 2 digits sensor off alarm.
• UL 2601-1 • ISO 9919
Pulse rate: 20 to 250 bpm ± 3 digits • EN/IEC 60601-1-2 (2nd ed.) Displayed saturation and pulse
Low perfusion: 20 to 250 bpm ± 3 digits rate alarm limits.
Emissions Compliance
ELECTRICAL EN55011, Group 1, Class B Backup speaker with escalating
Instrument alarm tones.
Output
Power requirements: 100 to 120 VAC, Optional Accessories
EIA-232 and RS-422 digital output
200 to 240 VAC, 50/60 Hz, 20 VA GCX mounting options
from serial port
Fuse rating: 0.5 Amperes Interface cables
Oxinet Communications Output Protocol
Carrying cases
Battery
Nurse call capability
Type: Sealed lead-acid internal battery
Adult specifications are shown for the OxiMax MAX-A
Analog output (0-1V); SpO2, pulse rate and MAX-N sensors with the OxiMax N-600x pulse oximeter.
Battery capacity: Typically 7 hours using
and plethsymographic waveform Neonate specifications are shown for MAX-N sensors with the
new, fully charged battery OxiMax N-600x pulse oximeter. Saturation accuracy will vary
Displays/Indicators by sensor type. Refer to Nellcor’s Sensor Accuracy Grid Card
Charge time: 8-12 hours for details. The low perfusion specifications apply to monitor
High quality LCD graphical screen. performance. Refer to the OxiMax N-600x pulse oximeter
Environmental operator’s manual for complete description, instructions,
Visual indicators: Pulse search, audible warnings, cautions and specifications. Specifications
Operating Temperature are subject to change without notice.
alarms silenced or off, interference
Instrument: 5°C to 40°C
indicator, low battery and battery
Transport/Storage Temperature charging, battery fuel gauge, sensor off,
(in shipping carton): -20°C to 70°C sensor disconnect, data in sensor and
SatSeconds clock.
Operating Humidity: 15% to 95%
noncondensing

Operating Altitude: -1,280 ft to 12,000 ft

COVIDIEN, COVIDIEN with logo and ™ marked brands are trademarks of Covidien AG or its affiliate.
© 2007 Covidien AG or its affiliate. All rights reserved. F.y 5399-1007 MN06207

6135 Gunbarrel Avenue 303-530-2300 [t] www.covidien.com


Boulder, CO 303-305-2221 [f]
80301

You might also like