This document provides error codes and descriptions for fixing issues with a Canon iR2530 printer. It lists several error codes ranging from E000 to E025 related to problems with sensors, motors, temperature detection and more. The remedies suggested include clearing errors, checking connections, and potentially replacing parts like sensors, motors, or circuit boards.
This document provides error codes and descriptions for fixing issues with a Canon iR2530 printer. It lists several error codes ranging from E000 to E025 related to problems with sensors, motors, temperature detection and more. The remedies suggested include clearing errors, checking connections, and potentially replacing parts like sensors, motors, or circuit boards.
This document provides error codes and descriptions for fixing issues with a Canon iR2530 printer. It lists several error codes ranging from E000 to E025 related to problems with sensors, motors, temperature detection and more. The remedies suggested include clearing errors, checking connections, and potentially replacing parts like sensors, motors, or circuit boards.
This document provides error codes and descriptions for fixing issues with a Canon iR2530 printer. It lists several error codes ranging from E000 to E025 related to problems with sensors, motors, temperature detection and more. The remedies suggested include clearing errors, checking connections, and potentially replacing parts like sensors, motors, or circuit boards.
1.Go through the following to clear the error: CLEAR > ENGIN > ERRCLR; and then turn Fixing temperature abnormal rise OFF and then ON the power. 2.Check The temperature detected by the E000- connection of the Connectors (Thermistor main thermistor does not rise to 0001 Connector and AC Connector). 3.Replace the the specified value during startup Fixing Main Thermistor (Film Unit). 4.Replace control. the Fixing Assembly. 5.Replace the DC Controller PCB (PCB4). 1.Go through the following to clear the error: CLEAR > ENGIN > ERRCLR; and then turn Fixing unit temperature rise OFF and then ON the power. 2.Check detection E001- connection of the Connectors (Thermistor The reading of the main 0000 Connector and AC Connector). 3.Replace the thermistor is 250 deg C or more Fixing Main Thermistor (Film Unit). 4.Replace continuously for 200 msec. the Fixing Assembly. 5.Replace the DC Controller PCB (PCB4). Fixing unit temperature rise 1.Go through the following to clear the error: detection E001- CLEAR > ENGIN > ERRCLR; and then turn The hardware circuit detects 0001 OFF and then ON the power. 2.Replace the overheating of the main or sub DC Controller PCB (PCB4). thermistor for 200 msec. 1.Go through the following to clear the error: CLEAR > ENGIN > ERRCLR; and then turn Fixing unit temperature rise OFF and then ON the power. 2.Check detection E001- connection of the Connectors (Thermistor The reading of the sub thermistor 0002 Connector and AC Connector). 3.Replace the is 295 deg C or more Fixing Main Thermistor (Film Unit). 4.Replace continuously for 200 msec. the Fixing Assembly. 5.Replace the DC Controller PCB (PCB4). Fixing unit temperature insufficient rise 1.Go through the following to clear the error: 1.The reading of the main CLEAR > ENGIN > ERRCLR; and then turn thermistor is less than 115 deg C OFF and then ON the power. 2.Check continuously for 400 msec 1.3 E002- connection of the Connectors (Thermistor sec after it has indicated 100 deg 0000 Connector and AC Connector). 3.Replace the C. 2.The reading of the main Fixing Main Thermistor (Film Unit). 4.Replace thermistor is less than 150 deg C the Fixing Assembly. 5.Replace the DC continuously for 400 msec 1.3 Controller PCB (PCB4). sec after it has indicated 140 deg C. 1.Go through the following to clear the error: Low fixing temperature detection CLEAR > ENGIN > ERRCLR; and then turn after standby OFF and then ON the power. 2.Check E003- The reading of the main connection of the Connectors (Thermistor 0000 thermistor is less than 140 deg C Connector and AC Connector). 3.Replace the continuously for 400 msec or Fixing Main Thermistor (Film Unit). 4.Replace more. the Fixing Assembly. 5.Replace the DC Controller PCB (PCB4). Thermistor disconnection 1.Check connection of the Connector (J214). detection error E004- 2.Replace the Film Unit. 3.Replace the Fixing When disconnection is detected 0000 Assembly. 4.Replace the DC Controller PCB with connector (J214) for 30 sec (PCB4). continuously. Unstable rotation of the Main Motor (M1) Detection is executed every 100 E010- 1.Replace the Main Motor (M1). 2.Replace the msec after the start of motor 0001 DC Controller PCB (PCB4). rotation; however, the drive detection signal is absent for 2 sec. Unstable rotation of the Main Motor (M1) E010- During motor rotation, detection 1.Replace the Main Motor (M1). 2.Replace the 0002 is executed every 100 msec; DC Controller PCB (PCB4). however, the drive signal is absent 5 times in sequence. Unstable rotation of the Fixing Motor (M2) Detection is executed every 100 E014- 1.Replace the Fixing Motor (M2). 2.Replace msec after the start of motor 0001 the DC Controller PCB (PCB4). rotation; however, the drive detection signal is absent for 2 sec. Unstable rotation of the Fixing Motor (M2) E014- During motor rotation, detection 1.Replace the Fixing Motor (M2). 2.Replace 0002 is executed every 100 msec; the DC Controller PCB (PCB4). however, the drive signal is absent 5 times in sequence. Error in Waste Toner Sensor E019- (S17) 1.Replace the Waste Toner Sensor (S17). 0000 Warning when the sensor goes 2.Replace the DC Controller PCB (PCB4). on for 2000 consecutive sheets, and error when the sensor goes on for 100 consecutive sheets. * Error occurs after the delivery if a paper in passage exists. The path between the sub hopper and the developing assembly is clogged with toner. The Developing Assembly Toner Sensor (TS1) detects the absence of toner,while the Sub 1.Check the rotation of hopper motor gear. (If Hopper Toner Sensor (TS2) rotating, false detection by the sensor is detects the presence of toner. doubted. Feed the toner to the developing unit E020- With the Developing Cylinder in service mode: CLEAR>ENGIN>TNRINST.) 0000 Clutch (CL3) turned on, the 2.Replace the Developing Assembly Toner hopper feedscrew motor (M7) is Sensor (TS1). 3.Replace the Sub Hopper rotated for 1 sec intermittently Toner Sensor (TS2). 4.Replace the DC 194 times; still, theDeveloping Controller PCB (PCB4). Assembly Toner Sensor (TS1) does not detect the presence of toner. * Error occurs after the delivery if a paper in passage exists. The connector (J207) of Developing Assembly Toner Sensor (TS1) is disconnected. 1.Check connection of the Connector (J207). The Developing Assembly Toner E024- 2.Replace the Developing Assembly Toner Sensor (TS1) connection 0000 Sensor (TS1). 3.Replace the DC Controller detection signal is absent for 100 PCB (PCB4). msec 10 times in sequence. * Error occurs after the delivery if a paper in passage exists. The Developing Assembly Toner Sensor (TS1) is disconnected <At LOW SPEED> - The developing assembly toner sensor (TS1) ON counter is checked every 2.5 seconds, and 1.Check connection of the Connector (J207). E024- the counter increments 1 count 2.Correct the cable. 3.Replace the Developing 0001 every 25 times when the sensor Assembly Toner Sensor (TS1). goes on, and 300 counts are reached. <At HIGH SPEED> - The developing assembly toner sensor (TS1) ON counter is checked every 1.5 seconds, and the counter increments 1 count every 15 times when the sensor goes on, and 300 counts are reached.
Code Description Remedy
The connector (J207) of Sub Hopper Toner Sensor (TS2) is disconnected. 1.Check connection of the Connector The Sub Hopper Toner Sensor E025- (J207). 2.Replace the Sub Hopper Toner (TS2) connection detection signal is 0000 Sensor (TS2). 3.Replace the DC Controller absent for 100 msec 10 times in PCB (PCB4). sequence. * Error occurs after the delivery if a paper in passage exists. Failure of the Bottle Motor (M6) The bottle motor (M6) is unlocked E025- when it goes on for 12 consecutive 1.Replace the Bottle Motor (M6). 0001 times at 0.1 sec. intervals. 2.Replace the DC Controller PCB (PCB4). * Error occurs after the delivery if a paper in passage exists. Failure of the Scanner Motor (M21) The Scanner Motor (M21) speed lock signal does not indicate a 1.Check the cable. 2.Replace the Laser E110- locked state a specific period of time Scanner Unit. 3.Replace the DC Controller 0001 after the Scanner Motor (M21) has PCB (PCB4). been started. * The same condition is detected after the error retry is performed. Failure of the Scanner Motor (M21) The speed lock signal indicates a deviation 10 times in sequence at 1.Check the cable. 2.Replace the Laser E110- intervals of 100 msec after the Scanner Unit. 3.Replace the DC Controller 0002 signal has indicated a locked state. PCB (PCB4). * The same condition is detected after the error retry is performed. Failure of the Scanner Motor (M21) The scanner motor (M21) speed 1.Check the cable. 2.Replace the Laser E110- lock signal does not indicate a Scanner Unit. 3.Replace the DC Controller 0003 locked state for 6.5 sec. after a PCB (PCB4). switchover is made from low to normal speed or for 8 sec. after a switchover is made from normal to low speed. * The same condition is detected after the error retry is performed. Error in EEPROM access 20 retries failed after error occurred E196- during communication with 1.Replace the DC Controller PCB (PCB4). 0000 EEPROM. * Error occurs after the delivery if a paper in passage exists. Error in communication of Laser 1.Check the cable. 2.Replace the Laser E197- Driver PCB (PCB14) Scanner Unit. 3.Replace the DC Controller 0000 Communication error 1 with image PCB (PCB4). PCB Error in communication of Laser 1.Check the cable. 2.Replace the Laser E197- Driver PCB (PCB14) Scanner Unit. 3.Replace the DC Controller 0001 Communication error 2 with image PCB (PCB4). PCB There is an error in the detection of 1.Disconnect and then connect the flexible the CIS home position. cable(Relay PCB (PCB2)-Main Controller 1.The attempt to detect the home PCB (PCB1) 64pin). 2.Replace the flexible E202- position fails when the CIS is moved cable. 3.Replace the CIS HP sensor (S31). 0000 forward. 4.Replace the Scanner Motor (M31). 2.The attempt to detect the home 5.Replace the Relay PCB (PCB2). position fails when the CIS is moved 6.Replace the Main Controller PCB back. (PCB1). Error in controller communication E240- The serial communication error such 1.Check the Connectors. 2.Replace the 0000 as parity error or overrun error is DC Controller PCB (PCB4). constantly detected. Error in controller communication E240- The serial communication error such 1.Check the Connectors. 2.Replace the 0001 as parity error or overrun error is DC Controller PCB (PCB4). detected while printing. E246- Writing to the counter PCB (FRAM) 0000 failed E247- Mismatched checksum between the 0000 Flash Rom and the FRAM Error in Zero Cross E261- Zero Cross failed to be detected for 1.Check the Connectors. 2.Replace the 0000 500ms or more while the relay was DC Controller PCB (PCB4). ON. * The same condition is detected after the error retry is performed.
Code Description Remedy
E354- Mismatched serial number for 0000 the SOFT-ID PCB Mismatched serial number E355- between the SOFT-ID, the 0000 Flash Rom and the FRAM E355- System information error 0004 E355- System information error 0005 Communication error 1.Check the cable. 2.Replace the Finisher E500- The communication with the Controller PCB (PCB1). 3.Replace the DC 0000 host machine is interrupted. Controller PCB. EEPROM error E505- 1.Replace the Finisher Controller PCB The checksum for the EEPROM 0001 (PCB1). data has an error. Shift Motor (M4) error The shift roller does not leave 1.Replace the Shift Roller HP Sensor (S2). E520- the shift roller home position 2.Replace the Shift Motor (M4). 3.Replace the 0001 when the Shift Motor (M4) has Finisher Controller PCB (PCB1). been driven for 1.2 seconds. Shift Motor (M4) error The shift roller does not return 1.Replace the Shift Roller HP Sensor (S2). E520- to the shift roller home position 2.Replace the Shift Motor (M4). 3.Replace the 0002 when the Shift Motor (M4) has Finisher Controller PCB (PCB1). been driven for 1.2 seconds. Stapler Motor (M10) error 1.Check the wiring between the Finisher The stapler does not leave the E531- Controller PCB and Stapler. 2.Replace the staple home position when the 8001 Stapler. 3.Replace the Finisher Controller PCB Staple Motor (M10) has been (PCB1). driven for 0.5 sec. Stapler Motor (M10) error 1.Check the wiring between the Finisher The stapler does not return to E531- Controller PCB and Stapler. 2.Replace the the staple home position when 8002 Stapler. 3.Replace the Finisher Controller PCB the Stapler Motor (M10) has (PCB1). been driven for 0.5 sec. 1.Replace the Stapler Move HP Sensor (S10). STP Move Motor (M1) error 2.Check the wiring between the Finisher The stapler does not leave the E532- Controller PCB and the STP Move Motor. stapler move home position 0001 3.Check the stapler shift base. 4.Replace the when the STP Move Motor (M1) STP Move Motor (M1). 5.Replace the Finisher has been driven for 0.25 sec. Controller PCB (PCB1). 1.Replace the Stapler Move HP Sensor (S10). STP Move Motor (M1) error 2.Check the wiring between the Finisher The stapler does not return to E532- Controller PCB and the STP Move Motor. the stapler move home position 0002 3.Check the stapler shift base. 4.Replace the when the STP Move Motor (M1) STP Move Motor (M1). 5.Replace the Finisher has been driven for 2.8 sec. Controller PCB (PCB1). Tray Lift Motor (M11) time out 1.Replace the Tray Lift Motor (M11). E540- error 2.Replace the Finisher Controller PCB 0001 The stack tray does not move (PCB1). within a specified time period. Tray Lift Motor (M11) closing detect switch error 1.Replace the Stack Tray Clock Sensor (S13). E540- The FG input cannot be 2.Replace the Tray Lift Motor (M11). 0005 detected when the Tray Lift 3.Replace the Finisher Controller PCB Motor (M11) has been driven for (PCB1). 0.1 second. Additional Tray Lift Motor (M12) 1.Replace the Additional Tray Lift Motor (M12). E542- time out error 2.Replace the Finisher Controller PCB 0001 The stack tray does not move (PCB1). within a specified time period.
Code Description Remedy
Additional Tray Lift Motor (M12) closing 1.Replace the Additional Tray Clock detect switch error Sensor (S23). 2.Replace the E542- The FG input cannot be detected when Additional Tray Lift Motor (M12). 0005 the Additional Tray Lift Motor (M12) has 3.Replace the Finisher Controller been driven for 0.1 second. PCB (PCB1). Shift Roller Release Motor (M5) error 1.Replace the Shift Roller Release The shift roller does not leave the shift E567- Sensor (S3). 2.Replace the Shift roller release home position when the 0001 Roller Release Motor (M5). 3.Replace Shift Roller Release Motor (M5) has the Finisher Controller PCB (PCB1). been driven for 0.1 sec. Shift Roller Release Motor (M5) error 1.Replace the Shift Roller Release E567- The shift roller does not return to the Sensor (S3). 2.Replace the Shift 0002 shift roller release home position when Roller Release Motor (M5). 3.Replace the Shift Roller Release Motor (M5) has the Finisher Controller PCB (PCB1). been driven for 0.06 sec. Gripper Open/Close Motor (M7) error 1.Replace the Grip Arm Sensor The gripper unit does not leave the E571- (S13). 2.Replace the Gripper gripper unit home position when the 0001 Open/Close Motor (M7). 3.Replace Gripper Open/Close Motor (M7) has the Finisher Controller PCB (PCB1). been driven for 0.25 seconds. Gripper Open/Close Motor (M7) error 1.Replace the Grip Arm Sensor The gripper unit does not return to the E571- (S13). 2.Replace the Gripper gripper unit home position when the 0002 Open/Close Motor (M7). 3.Replace Gripper Open/Close Motor (M7) has the Finisher Controller PCB (PCB1). been driven for 0.15 seconds. Gripper Unit Move Motor (M2) error 1.Replace the Gripper Unit HP The gripper unit does not leave the E575- Sensor (S7). 2.Replace the Gripper gripper unit home position when the 0001 Unit Move Motor (M2). 3.Replace the Gripper Unit Move Motor (M2) has been Finisher Controller PCB (PCB1). driven for 3.8 seconds. Gripper Unit Move Motor (M2) error 1.Replace the Gripper Unit HP The gripper unit does not return to the E575- Sensor (S7). 2.Replace the Gripper gripper unit home position when the 0002 Unit Move Motor (M2). 3.Replace the Gripper Unit Move Motor (M2) has been Finisher Controller PCB (PCB1). driven for 0.1 seconds. E602- The built-in SD card is not detected 0001 E602- Access to the built-in SD card failed 1105 Error in UFDI communication 1.Check and Replace the cable. E711- The communication system error (such 2.Replace the DC Controller PCB 0001 as reception timeout or checksum error) (PCB4). 3.Replace the Finisher occurred. Controller PCB. Erroneous communication with finisher 1.Check the cable. 2.Replace the DC E713- The communication does not restart by Controller PCB (PCB4). 3.Replace 0000 the error retry after the communication the Finisher Controller PCB. failure with the finisher. Erroneous communication with optional cassette or 2-way unit 1.Check the cable. 2.Replace the DC E716- After the presence of a cassette Controller PCB (PCB4). 3.Replace 0000 pedestal or a 2-way unit has been the Cassette Pedestal Driver PCB. detected, the communication fails to be 4.Replace the 2-way unit driver PCB. normal for 5 sec. E716- Failure of the communication with the 2- 1.Install the 2-way unit. 2.Check the 0010 way unit cable. 3.Replace the DC Controller When the communication with the 2- PCB (PCB4). 4.Replace the 2-way way unit is faulty after detecting the unit driver PCB. connection with the finisher. E719- Erroneous communication with New 0000 Card Reader (serial communication) E719- Erroneous communication with Coin 0002 Vendor (serial communication)
Code Description Remedy
E736- Erroneous communication between 0000 CCU and controller. E744- Mismatched version between the 0001 language file and the Bootable E744- Oversized language file in HDD 0002 E744- Mismatched version between the 0003 language file and the Bootable E744- Language file reading error 0004 Failure of the Power Supply Cooloing Fan (FAN6) 1.Disconnect and then connect the When lock signal is detected for 5 connector (J205) on the DC Controller E804- sec while the Power Supply PCB (PCB4). 2.Replace the Power Supply 0000 Cooloing Fan (FAN6) is stopped. Cooloing Fan (FAN6). 3.Replace the DC * The same condition is detected Controller PCB (PCB4). after the error retry is performed. Unstable rotation of the Power Supply Cooloing Fan (FAN6) 1.Disconnect and then connect the When lock signal failed to be connector (J205) on the DC Controller E804- detected for 5 sec while the Power PCB (PCB4). 2.Replace the Power Supply 0001 Supply Cooloing Fan (FAN6) is Cooloing Fan (FAN6). 3.Replace the DC driven. Controller PCB (PCB4). * The same condition is detected after the error retry is performed. Failure of the Exhaust Fan (Rear) 1.Disconnect and then connect the (FAN3) connector (J206) on the DC Controller E805- When lock signal is detected for 5 PCB (PCB4). 2.Replace the Exhaust Fan 0000 sec while the Exhaust Fan (Rear) (Rear) (FAN3). 3.Replace the DC (FAN3) is stopped. Controller PCB (PCB4). * The same condition is detected after the error retry is performed. Unstable rotation of the Exhaust Fan (Rear) (FAN3) or Finisher Fan 1 (M8) or Finisher Fan 2 (M9) 1.When lock signal failed to be detected for 5 sec while the Exhaust 1.Disconnect and then connect the Fan (Rear) (FAN3) is driven. connector (J206) on the DC Controller E805- 2.When lock signal failed to be PCB (PCB4). 2.Replace the Exhaust Fan 0001 detected for 5 sec while the Finisher (Rear) (FAN3). 3.Replace the Finisher Fan Fan 1 (M8) is driven. 3.When lock 1 (M8). 4.Replace the Finisher Fan 2 (M9). signal failed to be detected for 5 sec 5.Replace the DC Controller PCB (PCB4). while the Finisher Fan 2 (M9) is driven. * The same condition is detected after the error retry is performed. Failure of the Exhaust Fan (Front) (FAN4) 1.Disconnect and then connect the When lock signal is detected for 5 connector (J206) on the DC Controller E805- sec while the Exhaust Fan (Front) PCB (PCB4). 2.Replace the Exhaust Fan 0002 (FAN4) is stopped. * The same (Front) (FAN4). 3.Replace the DC condition is detected after the error Controller PCB (PCB4). retry is performed. Unstable rotation of the Exhaust Fan (Front) (FAN4) 1.Disconnect and then connect the When lock signal failed to be connector (J206) on the DC Controller E805- detected for 5 sec while the Exhaust PCB (PCB4). 2.Replace the Exhaust Fan 0003 Fan (Front) (FAN4) is driven. (Front) (FAN4). 3.Replace the DC * The same condition is detected Controller PCB (PCB4). after the error retry is performed.