Nokia Networks

WCDMA RAN, Rel. WCDMA


16, Operating Documentation,
Issue 04

Installing and Cabling Flexi


Multiradio Remote Radio
Heads
DN09185846
Issue 06A
Approval Date 2016-02-19

 
 
Installing and Cabling Flexi Multiradio Remote Radio Heads

The  information  in  this  document  applies  solely  to  the  hardware/software  product  (“Product”)  specified
herein, and only as specified herein.

This document is intended for use by Nokia Solutions and Networks' customers (“You”) only, and it may not
be used except for the purposes defined in the agreement between You and Nokia Solutions and Networks
(“Agreement”)  under  which  this  document  is  distributed.  No  part  of  this  document  may  be  used,  copied,
reproduced,  modified  or  transmitted  in  any  form  or  means  without  the  prior  written  permission  of  Nokia
Solutions  and  Networks.  If  you  have  not  entered  into  an  Agreement  applicable  to  the  Product,  or  if  that
Agreement has expired or has been terminated, You may not use this document in any manner and You
are obliged to return it to Nokia Solutions and Networks and destroy or delete any copies thereof.

The  document  has  been  prepared  to  be  used  by  professional  and  properly  trained  personnel,  and  You
assume full responsibility when using it. Nokia Solutions and Networks welcome Your comments as part of
the process of continuous development and improvement of the documentation.

This  document  and  its  contents  are  provided  as  a  convenience  to  You.  Any  information  or  statements
concerning the suitability, capacity, fitness for purpose or performance of the Product are given solely on
an “as is” and “as available” basis in this document, and Nokia Solutions and Networks reserves the right
to change any such information and statements without notice. Nokia Solutions and Networks has made all
reasonable efforts to ensure that the content of this document is adequate and free of material errors and
omissions,  and  Nokia  Solutions  and  Networks  will  correct  errors  that  You  identify  in  this  document.  But,
Nokia Solutions and Networks' total liability for any errors in the document is strictly limited to the correction
of such error(s). Nokia Solutions and Networks does not warrant that the use of the software in the Product
will be uninterrupted or error-free.

NO  WARRANTY  OF  ANY  KIND,  EITHER  EXPRESS  OR  IMPLIED,  INCLUDING  BUT  NOT  LIMITED  TO
ANY  WARRANTY  OF  AVAILABILITY,  ACCURACY,  RELIABILITY,  TITLE,  NON-INFRINGEMENT,
MERCHANTABILITY  OR  FITNESS  FOR  A  PARTICULAR  PURPOSE,  IS  MADE  IN  RELATION  TO  THE
CONTENT  OF  THIS  DOCUMENT.  IN  NO  EVENT  WILL  NOKIA  SOLUTIONS  AND  NETWORKS  BE
LIABLE  FOR  ANY  DAMAGES,  INCLUDING  BUT  NOT  LIMITED  TO  SPECIAL,  DIRECT,  INDIRECT,
INCIDENTAL  OR  CONSEQUENTIAL  OR  ANY  LOSSES,  SUCH  AS  BUT  NOT  LIMITED  TO  LOSS  OF
PROFIT,  REVENUE,  BUSINESS  INTERRUPTION,  BUSINESS  OPPORTUNITY  OR  DATA  THAT  MAY
ARISE FROM THE USE OF THIS DOCUMENT OR THE INFORMATION IN IT, EVEN IN THE CASE OF
ERRORS IN OR OMISSIONS FROM THIS DOCUMENT OR ITS CONTENT.

This document is Nokia Solutions and Networks’ proprietary and confidential information, which may not be
distributed  or  disclosed  to  any  third  parties  without  the  prior  written  consent  of  Nokia  Solutions  and
Networks.

Nokia  is  a  registered  trademark  of  Nokia  Corporation.  Other  product  names  mentioned  in  this  document
may be trademarks of their respective owners, and they are mentioned for identification purposes only.

Copyright © 2016 Nokia Solutions and Networks. All rights reserved.

f Important Notice on Product Safety


  This product may present safety risks due to laser, electricity, heat, and other sources of danger.

Only  trained  and  qualified  personnel  may  install,  operate,  maintain  or  otherwise  handle  this
product and only after having carefully read the safety information applicable to this product.

The  safety  information  is  provided  in  the  Safety  Information  section  in  the  “Legal,  Safety  and
Environmental Information” part of this document or documentation set.

Nokia  Solutions  and  Networks  is  continually  striving  to  reduce  the  adverse  environmental  effects  of  its
products and services. We would like to encourage you as our customers and users to join us in working
towards a cleaner, safer environment. Please recycle product packaging and follow the recommendations
for power use and proper disposal of our products and their components.

If you should have questions regarding our Environmental Policy or any of the environmental services we
offer, please contact us at Nokia Solutions and Networks for any additional information.

2 DN09185846 Issue: 06A
Installing and Cabling Flexi Multiradio Remote Radio Heads

Table of Contents
This document has 163 pages
   
Summary of changes................................................................... 12
   
1 Introduction to installing Flexi RRH modules............................... 14
   
2 Unpacking Flexi Multiradio RRH delivery.....................................16
2.1 Contents of the Flexi 2x40 delivery.............................................. 16
2.2 Contents of the Flexi 2x60 delivery.............................................. 17
2.3 Contents of the Release 4 RRH delivery..................................... 17
2.4 Contents of the Flexi RRH 2-pipe 700/840 100W (FHPC) delivery.
18
2.5 Contents of the Flexi RRH 4TX 2100 (FRIG and FHGB) delivery...
18
2.6 Contents of the Flexi Pole Mounting Kit (FPKA) delivery.............18
2.7 Contents of the Flexi Pole Kit (FPKC) delivery............................ 19
2.8 Contents of the mounting bracket for pole (FMFC) delivery........ 20
2.9 Contents of the pole mounting kit (VMPB) delivery......................20
2.10 Contents of the mounting kit for floor, wall and pole (FMFA)
delivery.........................................................................................21
   
3 Installation tools and torque values..............................................23
3.1 BTS installation tools and equipment...........................................23
3.2 Torque values...............................................................................24
   
4 Before you start............................................................................26
   
5 Dimension guidelines for wall and pole mounting........................ 28
   
6 Installing and cabling Flexi 2x40 W RRH onto a pole.................. 31
   
7 Installing and cabling Flexi 2x60 W RRH onto a pole.................. 44
   
8 Installing and cabling RRH Release 4 onto a pole.......................57
   
9 Installing and cabling Flexi RRH 2TX 730 (FRLB) onto a pole.... 76
   
10 Installing and cabling Flexi RRH 4TX 2100 (FRIG and FHGB) onto
a pole........................................................................................... 87
   
11 Installing and cabling Flexi RRH 2TX 850 (FHCA) onto a pole....99
   
12 Installing and cabling Flexi TRS External Filter for FHCA (FFCB)
onto a pole................................................................................. 107
   
13 Installing and cabling Flexi TRS External Filter for FHCA (FFCB)
onto a wall.................................................................................. 115
   
14 Installing and cabling Flexi RRH 2-pipe 700/840 (FHPC) onto a
pole.............................................................................................117

Issue: 06A DN09185846 3
Installing and Cabling Flexi Multiradio Remote Radio Heads

   
15 Installing and cabling s-RRH850 (FHCB)...................................122
   
16 Installing and cabling s-RRH1800 (FHEC).................................123
   
17 Installing Flexi RRH 2TX onto a pole opposite to FMFA............ 124
   
18 Installing Flexi 2x40 W RRH onto a wall.................................... 127
   
19 Installing Flexi 2x60 W RRH onto a wall.................................... 131
   
20 Installing RRH Release 4 onto a wall.........................................135
   
21 Installing Flexi RRH 2-pipe 700/840 (FHPC) onto a wall........... 137
   
22 Installing first RRH with FPKC................................................... 140
   
23 Installing a second RRH with FPKC...........................................146
   
24 Installing additional Remote Radio Heads onto the same side with
FPKC..........................................................................................150
   
25 Installing additional Remote Radio Heads onto opposite sides with
FPKC..........................................................................................156
   
26 Flexi RRH 2TX external alarm connection................................. 162

4 DN09185846 Issue: 06A
Installing and Cabling Flexi Multiradio Remote Radio Heads

List of Figures
Figure 1 Flexi pole mounting kit (FPKA)........................................................... 19
Figure 2 Contents of the pole mounting kit (VMPB) delivery............................ 21
Figure 3 Delivery contents of FMFA................................................................. 22
Figure 4 Dimension guidelines for installations onto poles (2x40 W RRH)...... 28
Figure 5 2x60 RRH Spacing............................................................................. 29
Figure 6 Dimension guidelines for installations onto poles (2x60 W RRH)...... 29
Figure 7 Dimension guidelines for installations onto walls (2x40 W RRH)....... 30
Figure 8 Dimension guidelines for installations onto walls (2x60 W RRH)....... 30
Figure 9 FRGQ interfaces.................................................................................31
Figure 10 FRMB, FRHB, FHEA, and FHDA interfaces.......................................32
Figure 11 Releasing strain relief......................................................................... 33
Figure 12 Releasing strain relief......................................................................... 33
Figure 13 Fixing the upper screws to the FPKA bracket.................................... 34
Figure 14 Applying the lower screws to the FPKA..............................................35
Figure 15 Attaching DC cable clamp.................................................................. 35
Figure 16 Connecting grounding cable...............................................................36
Figure 17 Wrapping tape around shielded DC cable.......................................... 36
Figure 18 Wrapping extra tape around the DC cable......................................... 36
Figure 19 Inserting DC power cable into an IP boot........................................... 37
Figure 20 Removing narrow end of an IP boot................................................... 38
Figure 21 Properly secured shielded DC cable (left) and non-shielded DC cable
(right).................................................................................................. 39
Figure 22 Connecting DC feeder cable wires..................................................... 39
Figure 23 Example of conduit usage.................................................................. 40
Figure 24 Fixing DC cable clamp........................................................................40
Figure 25 Connecting antenna cables................................................................ 41
Figure 26 Connecting RET cable........................................................................41
Figure 27 Connecting optical cables...................................................................42
Figure 28 Connecting EAC cable....................................................................... 42
Figure 29 Connecting RX out cable....................................................................42
Figure 30 Connecting LMP cable....................................................................... 43
Figure 31 Securing cables with cable ties.......................................................... 43
Figure 32 FHDB, FHEB, FHEF, and FHEG interfaces........................................44
Figure 33 Lower fixing bracket of 2x60 W RRH..................................................45
Figure 34 Placing the RRH upside down (2x60 W RRH)................................... 46
Figure 35 Aligning lower fixing bracket............................................................... 46
Figure 36 Attaching DC cable clamp (2x60 W RRH)..........................................47
Figure 37 Lifting RRH onto a pole...................................................................... 47
Figure 38 Connecting grounding cable (2x60 W RRH)...................................... 48

Issue: 06A DN09185846 5
Installing and Cabling Flexi Multiradio Remote Radio Heads

Figure 39 Removing the DC protective cover (2x60 W RRH)............................ 48
Figure 40 Removing and reserving DC protective cover.................................... 49
Figure 41 Wrapping tape around DC cable........................................................ 49
Figure 42 Inserting DC feeder cable to an IP boot............................................. 50
Figure 43 Removing narrow end of an IP boot................................................... 51
Figure 44 Connecting wires to screw terminals (2x60 W RRH)..........................52
Figure 45 Connecting braid to the middle screw terminal (2x60 W RRH).......... 52
Figure 46 Fixing the IP boot (2x60 W RRH)....................................................... 53
Figure 47 Example of conduit usage.................................................................. 53
Figure 48 Securing the cable with the cable clamp (2x60 W RRH)....................54
Figure 49 Connecting the RET cable (2x60 W RRH)......................................... 54
Figure 50 Connecting antenna cables (2x60 W RRH)........................................55
Figure 51 Connecting the EAC cable (2x60 W RRH)......................................... 55
Figure 52 Connecting optical transceiver and cable (2x60 W RRH).................. 55
Figure 53 FRGY and FRAA interfaces............................................................... 57
Figure 54 FRCC and FRCG interfaces...............................................................58
Figure 55 FHFB, FRBE, FRBF, FRBG, FRNC, FRHG, FHEH, and FHED
interfaces............................................................................................ 58
Figure 56 Lower mounting bracket of RRH Release 4....................................... 59
Figure 57 Vertical spacing options for the RRH Release 4.................................60
Figure 58 Assembling the lower pole bracket with the lower fixing bracket for a
FHFB.................................................................................................. 62
Figure 59 RRH with the plastic cover faced down.............................................. 62
Figure 60 Attaching a DC clamp.........................................................................63
Figure 61 Aligning key holes on the lower fixing bracket....................................63
Figure 62 Sliding lower bracket into place.......................................................... 64
Figure 63 RRH with lower bracket in place.........................................................64
Figure 64 Lifting RRH onto a pole...................................................................... 65
Figure 65 Connecting grounding cable (4 ANT)................................................. 66
Figure 66 Connecting antenna cables (4 ANT).................................................. 66
Figure 67 Wrapping tape around DC cable........................................................ 67
Figure 68 Wrapping extra tape around DC cable............................................... 67
Figure 69 Inserting DC power cable into an IP boot........................................... 68
Figure 70 Removing narrow end of an IP boot................................................... 69
Figure 71 Properly secured shielded DC cable (left) and non-shielded DC cable
(right).................................................................................................. 70
Figure 72 Connecting DC feeder cable wires..................................................... 70
Figure 73 Example of conduit usage.................................................................. 71
Figure 74 Securing DC cable clamp................................................................... 71
Figure 75 FRNC DC cable..................................................................................72
Figure 76 Connecting FRNC DC cable...............................................................72

6 DN09185846 Issue: 06A
Installing and Cabling Flexi Multiradio Remote Radio Heads

Figure 77 Connecting RET and EAC cables (4 ANT).........................................73
Figure 78 Connecting optical cables (4 ANT)..................................................... 73
Figure 79 Connecting RXO cables (4 ANT)........................................................74
Figure 80 Securing cables with ties and clamps.................................................74
Figure 81 Connecting all the cables for FRCC and FRCG................................. 74
Figure 82 Mounting additional modules onto a pole........................................... 75
Figure 83 FRLB interfaces..................................................................................76
Figure 84 Releasing strain relief plate................................................................ 77
Figure 85 Fixing FPKA onto FRLB..................................................................... 77
Figure 86 Fixing strain relief screws................................................................... 78
Figure 87 Lifting FRLB........................................................................................79
Figure 88 Fixing FPKA lower bracket................................................................. 80
Figure 89 Connecting grounding cable...............................................................80
Figure 90 Connecting EAC cable....................................................................... 81
Figure 91 Connecting LMP cable....................................................................... 81
Figure 92 Connecting optical cables...................................................................82
Figure 93 Connecting antenna cables................................................................ 82
Figure 94 Wrapping tape around DC cable........................................................ 83
Figure 95 Inserting DC feeder cable into an IP boot...........................................83
Figure 96 Removing narrow end of an IP boot................................................... 84
Figure 97 Example of conduit usage.................................................................. 84
Figure 98 Attaching DC cable clamp.................................................................. 85
Figure 99 Securing a DC cable in place............................................................. 85
Figure 100 Connecting RET cable........................................................................86
Figure 101 Connecting two RX out cable............................................................. 86
Figure 102 Securing cables with cable ties.......................................................... 86
Figure 103 FRIG interfaces.................................................................................. 87
Figure 104 FHGB interfaces................................................................................. 88
Figure 105 Releasing strain relief......................................................................... 89
Figure 106 Fixing FPKA onto FRIG...................................................................... 89
Figure 107 Fixing strain relief screws................................................................... 90
Figure 108 ............................................................................................................91
Figure 109 Attaching FPKA lower bracket............................................................92
Figure 110 Connecting a grounding cable............................................................92
Figure 111 Connecting EAC cable....................................................................... 93
Figure 112 Connecting LMP cable....................................................................... 93
Figure 113 Connecting antenna cables................................................................ 94
Figure 114 Wrapping tape around DC cable........................................................ 94
Figure 115 Inserting DC power cable into an IP boot........................................... 95
Figure 116 Removing narrow end of an IP boot................................................... 95

Issue: 06A DN09185846 7
Installing and Cabling Flexi Multiradio Remote Radio Heads

Figure 117 Example of conduit usage.................................................................. 96
Figure 118 Attach DC cable clamp....................................................................... 96
Figure 119 Securing DC cable in place................................................................ 97
Figure 120 Connecting RX out cable....................................................................97
Figure 121 Securing cables with cable ties.......................................................... 98
Figure 122 FHCA interfaces................................................................................. 99
Figure 123 Releasing strain relief....................................................................... 100
Figure 124 Releasing strain relief....................................................................... 100
Figure 125 Fixing FHCA to the FPKA bracket.................................................... 101
Figure 126 Attaching DC cable clamp................................................................ 102
Figure 127 Connecting antenna cables.............................................................. 103
Figure 128 Connecting optical cables.................................................................104
Figure 129 Wrapping tape around DC cable...................................................... 104
Figure 130 Inserting DC power cable into an IP boot......................................... 105
Figure 131 Removing narrow end of an IP boot................................................. 105
Figure 132 Fixing DC power cable..................................................................... 106
Figure 133 Threading hose clamps on a mounting bracket................................107
Figure 134 Hose clamps in place....................................................................... 108
Figure 135 Mounting FFCB on a pole.................................................................109
Figure 136 Tightening worm screw assembly.....................................................110
Figure 137 FFCB on a pole................................................................................. 111
Figure 138 Connecting FFCB grounding cable (M5).......................................... 112
Figure 139 Connecting jumper cable to BTS1.................................................... 113
Figure 140 Connecting jumper cable to ANT1.................................................... 114
Figure 141 Marking FFCB screw hole locations................................................. 115
Figure 142 Fixing FFCB on a wall.......................................................................116
Figure 143 FHPC interfaces............................................................................... 117
Figure 144 Installing a static mounting bracket to the FPKA.............................. 118
Figure 145 Installing FHPC onto a vertical pole..................................................119
Figure 146 FHPC mounted onto a pole with a mounting bracket....................... 119
Figure 147 Connecting a grounding cable..........................................................120
Figure 148 Connecting antenna cables.............................................................. 120
Figure 149 Connecting DC power cable.............................................................121
Figure 150 Connecting power supply................................................................. 122
Figure 151 Connecting power supply................................................................. 123
Figure 152 Moving RRH mounting kit brackets.................................................. 124
Figure 153 Releasing strain relief....................................................................... 125
Figure 154 Attaching strain relief screws............................................................126
Figure 155 Drilling mounting holes (RRH mounting kit fixing bolts fixed to the
innermost holes)............................................................................... 127

8 DN09185846 Issue: 06A
Installing and Cabling Flexi Multiradio Remote Radio Heads

Figure 156 Drilling mounting holes (RRH mounting kit fixing bolts fixed to the
outermost holes)...............................................................................128
Figure 157 Lifting RRH onto a wall..................................................................... 128
Figure 158 Releasing strain relief....................................................................... 129
Figure 159 Fixing strain relief screws................................................................. 129
Figure 160 Attaching DC cable clamp................................................................ 130
Figure 161 Placing the RRH upside down (2x60 W RRH)................................. 131
Figure 162 Aligning lower fixing bracket............................................................. 132
Figure 163 Attaching DC cable clamp (2x60 W RRH)........................................132
Figure 164 Drilling mounting holes..................................................................... 133
Figure 165 Lifting RRH onto a wall..................................................................... 134
Figure 166 Drilling mounting holes..................................................................... 135
Figure 167 Lifting RRH onto a wall..................................................................... 136
Figure 168 Drilling holes in a wall for FHPC....................................................... 137
Figure 169 Mounting a static mounting bracket on a wall...................................138
Figure 170 Mounting FHPC module onto a static mounting bracket.................. 138
Figure 171 FHPC mounted onto a wall with a mounting bracket........................139
Figure 172 Screw cut locations...........................................................................140
Figure 173 Screw installation slots..................................................................... 140
Figure 174 Placing FPKC upper brackets around a pole................................... 141
Figure 175 Inserting screws................................................................................142
Figure 176 Mounting a lower bracket................................................................. 142
Figure 177 Fixing lower bracket..........................................................................143
Figure 178 Fixing counterpart of a lower bracket............................................... 144
Figure 179 Tightening screws on an upper bracket............................................144
Figure 180 Inserting screws to upper brackets...................................................146
Figure 181 Fixing the lower bracket to a RRH....................................................147
Figure 182 Lifting RRH to a pole........................................................................ 148
Figure 183 Tightening screws on an upper bracket............................................148
Figure 184 Fixing a lower bracket.......................................................................149
Figure 185 Installing an upper bracket............................................................... 150
Figure 186 Inserting screws to an upper bracket................................................151
Figure 187 Fixing lower bracket to a RRH..........................................................151
Figure 188 Lifting RRH to a pole........................................................................ 152
Figure 189 Fixing counterpart of a lower bracket............................................... 153
Figure 190 Tightening screws on an upper bracket............................................153
Figure 191 Third RRH installed.......................................................................... 154
Figure 192 Installing fourth RRH........................................................................ 155
Figure 193 Installing upper bracket.................................................................... 156
Figure 194 Inserting screws to the upper brackets.............................................157

Issue: 06A DN09185846 9
Installing and Cabling Flexi Multiradio Remote Radio Heads

Figure 195 Fixing lower bracket to RRH.............................................................157
Figure 196 Lifting RRH to the pole..................................................................... 158
Figure 197 Securing counterpart of lower bracket..............................................159
Figure 198 Tightening screws on upper bracket.................................................160
Figure 199 Installing fourth RRH........................................................................ 161
Figure 200 Flexi System Alarm Cable for Flexi RRH 2TX.................................. 162

10 DN09185846 Issue: 06A
Installing and Cabling Flexi Multiradio Remote Radio Heads

List of Tables
Table 1 Releases covered by the document................................................... 12
Table 2 Allowed cable diameters.....................................................................18
Table 3 The Flexi pole mounting kit (FPKA) delivery content..........................19
Table 4 The Flexi pole kit (FPKC) delivery content......................................... 20
Table 5 Tools for installation............................................................................ 23
Table 6 Torque values for the BTS.................................................................. 24
Table 7 Installation tools..................................................................................61
Table 8 Pole diameter table related to cut location and installation slot for
optimum pole mounting.................................................................... 141
Table 9 Flexi RRH 2 TX EAC pinout............................................................. 162

Issue: 06A DN09185846 11
   

Summary of changes Installing and Cabling Flexi Multiradio Remote Radio
Heads

Summary of changes
Changes between document issues are cumulative. Therefore, the latest document
issue contains all changes made to previous issues.

This document is common for all Radio Access Technologies (RAT). The document
contains information about solutions that are unavailable or unsupported in specific SW
or RAT releases. Table RAT releases covered by the document lists all SW releases
covered by the content of this document. For features supported in your SW release, see
the respective feature documentation chapter in the system library.

Table 1 Releases covered by the document

Radio Access Technology (RAT) Product release

WCDMA RAN RU50, RU50 EP1, WCDMA 16

Long Term Evolution (LTE) RL70, FDD-LTE 15A, FDD-LTE 16

Changes between issues 06 (2015-12-04) and 06A (2016-02-19)

Installing and cabling Flexi 2x60 W RRH onto a pole


• Figure 38: Connecting grounding cable (2x60 W RRH) has been updated.

Installing and cabling RRH Release 4 onto a pole


• Figure 65: Connecting grounding cable (4 ANT) has been updated.

Installing and cabling Flexi RRH 2-pipe 700/840 (FHPC) onto a pole
• Static mounting bracket has been updated.
• Figure 145: Installing FHPC onto a vertical pole: FHPC adapter has been lifted up to
70 mm.

Installing Flexi RRH 2-pipe 700/840 (FHPC) onto a wall


• Static mounting bracket has been updated.
• Figure 170: Mounting FHPC module onto a static mounting bracket: FHPC adapter
has been lifted up to 70 mm.

Changes between issues 05A (2015-09-23) and 06 (2015-12-04)


Introduction to installing Flexi RRH modules
• Flexi RRH 4TX 1800 (FHED) module has been added to the list.
• Flexi RRH 4TX 2600 (FRHG) module has been added to the list.
• Flexi RRH 4TX 1800 (FHEH) module has been added to the list.
• Flexi RRH 2TX 450 (FRAA) module has been added to the list.
• FHFB name has been changed.
• FRIG name has been changed.
• FHDB name has been changed.

12 DN09185846 Issue: 06A
   

Installing and Cabling Flexi Multiradio Remote Radio Summary of changes
Heads

Dimension guidelines for wall and pole mounting


• Figure 4: Dimension guidelines for installations onto poles (2x40 W RRH) has been
updated.
• Figure 6: Dimension guidelines for installations onto poles (2x60 W RRH) has been
updated.
• Figure 7: Dimension guidelines for installations onto walls (2x40 W RRH) has been
updated.
• Figure 8: Dimension guidelines for installations onto walls (2x60 W RRH) has been
updated.

Installing and cabling Flexi 2x40 W RRH onto a pole


• Note in Connect the DC power cable. step has been added.
• Figure 24: Fixing DC cable clamp has been updated.

Installing and cabling Flexi 2x60 W RRH onto a pole


• Figure 33: Lower fixing bracket of 2x60 W RRH has been added.
• Figure 36: Attaching DC cable clamp (2x60 W RRH) has been updated.
• Figure 39: Removing the DC protective cover (2x60 W RRH) has been updated.
• Figure 40: Removing and reserving DC protective cover has been updated.

Installing and cabling Flexi RRH 4TX 2100 (FRIG and FHGB) onto a pole
• Title has been changed.

Changes between issues 05 (2015-03-18) and 05A (2015-09-23)


Introduction to installing Flexi RRH modules
• Flexi RRH 2-pipe 700/840 100W (FHPC) module has been added to the list.

Issue: 06A DN09185846 13
   

Introduction to installing Flexi RRH modules Installing and Cabling Flexi Multiradio Remote Radio
Heads

1 Introduction to installing Flexi RRH modules


Information on Flexi RRH modules and the document structure.

Use Flexi Pole Mounting Kit (FPKA) when installing Flexi Remote Radio Head onto
poles. If your FPKA includes both plinth (FMFA) and RRH 2TX installations, see
Installing Flexi RRH 2TX on the pole opposite to FMFA for instructions.
You can also use Flexi Pole Mounting Kit (FPKC) when installing Flexi Remote Radio
Head 2TX onto a pole. To do this, see Installing Flexi RRH 2TX on the pole with FPKC
for instructions.
For the additional information on Flexi RRH modules, see Flexi Multiradio BTS RF
Module and Remote Radio Head Description.
For pole and wall installation instructions for the following 2x40 W modules, see Installing
2x40 W RRH on a pole and Installing 2x40 W RRH on the wall:

• Flexi RRH 2TX 800EU (FRMB)
• Flexi RRH 2TX 2600 (FRHB)
• Flexi RRH 2TX 2100 (FRGQ)
• Flexi RRH 2TX 1800 (FHEA)
• Flexi RRH 2TX 900 (FHDA)

For pole and wall installation instructions for the following 2x60 W modules, see Installing
2x60 W RRH on a pole and Installing 2x60 W RRH on the wall:

• Flexi RRH 2TX 900 (FHDB)
• Flexi RRH 2TX 1800 (FHEB)
• Flexi RRH 2TX 1800 (FHEF)
• Flexi RRH 2TX 1800 (FHEG)

For pole and wall installation instructions for the following Release 4 modules, see
Installing and cabling RRH Release 4 onto a pole and Installing RRH Release 4 onto a
wall:
• Flexi RRH 4TX 1900 (FHFB)
• Flexi RRH 2TX 2100 (FRGY)
• Flexi RRH 2TX 750 (FRBE)
• Flexi RRH 4TX 760 (FRBF)
• Flexi RRH 2TX 730 (FRBG)
• Flexi RRH 2TX 850 (FRCC)
• Flexi RRH 4TX 2300 (FRNC)
• Flexi RRH 2TX 850 (FRCG)
• Flexi RRH 4TX 1800 (FHED)
• Flexi RRH 4TX 2600 (FRHG)
• Flexi RRH 4TX 1800 (FHEH)
• Flexi RRH 2TX 450 (FRAA)

For pole installation instructions for the following modules, see Installing and cabling
Flexi RRH 4TX 2100 (FRIG and FHGB) onto a pole:

14 DN09185846 Issue: 06A
   

Installing and Cabling Flexi Multiradio Remote Radio Introduction to installing Flexi RRH modules
Heads

• Flexi RRH 4TX 2100 (FRIG)
• Flexi RRH 4TX 2100 (FHGB)

For Flexi RRH 2-pipe 700/840 (FHPC) installation instructions, see Installing and cabling
Flexi RRH 2-pipe 700/840 (FHPC) onto a pole and Installing Flexi RRH 2-pipe 700/840
(FHPC) onto a wall.
For Flexi RRH 2TX 730 (FRLB) installation instructions, see Installing Flexi RRH 2TX
730 (FRLB) on the pole.
For Flexi RRH 2TX 850 (FHCA) installation instructions, see Installing Flexi RRH 2TX
850 (FHCA) on the pole, Installing Flexi TRS External Filter for FHCA (FFCB) on the
pole or Installing Flexi TRS External Filter for FHCA (FFCB) on the wall
If Flexi Power AC/DC sub-module (FPAC/D/E) is also to be installed, see the instructions
in Installing Flexi Multiradio Base Station and Flexi Multiradio 10 Base Station Optional
Items.

Issue: 06A DN09185846 15
   

Unpacking Flexi Multiradio RRH delivery Installing and Cabling Flexi Multiradio Remote Radio
Heads

2 Unpacking Flexi Multiradio RRH delivery


List of items of the Flexi FDD-LTE Remote Radio Heads delivery.

Before you start


Before installing the Remote Radio Head, unpack the delivery carefully and check to
make sure that all required items are undamaged and present.

w NOTICE: Electrostatic discharge (ESD) might damage the modules. Wear an ESD wrist
strap or use a corresponding method when handling the modules.

Procedure

1 Carefully check the contents of the delivery.

2 Remove the items from the package.

3 Check that the delivery is complete and undamaged.

4 Recycle the packaging material.

5 Proceed to the module installation procedure.

2.1 Contents of the Flexi 2x40 delivery


List of items of the Flexi RRH 2x40 (FRGQ, FRMB, FRHB, FHEA, and FHDA) delivery.
The Flexi RRH 2TX 2100 (FRGQ)
The Flexi RRH 2TX 2100 (FRGQ) delivery contains:

• Remote Radio Head (FRGQ)
• 1 x IP boot for the DC cable
• 1 x grounding cable
• 2 x strain relief clamps for optical cables
• 1 x cable clamp to secure the DC cable + 2 x screws
• 1 x M5x12 screw
• 7 x cable ties
The Flexi RRH 2TX (FRMB, FRHB, FHEA, and FHDA)
The Flexi Remote Radio Head 2TX (FRMB, FRHB, FHEA, and FHDA) delivery contains:
• Remote Radio Head (FRMB)
• 1 x IP boot for the DC cable
• 1 x grounding cable

16 DN09185846 Issue: 06A
   

Installing and Cabling Flexi Multiradio Remote Radio Unpacking Flexi Multiradio RRH delivery
Heads

• 2 x strain relief clamps for optical cables
• 1 x cable clamp to secure the DC cable
• 2 x screws to secure the cable clamp
• 1 x M5x12 screw
• 8 x cable ties

2.2 Contents of the Flexi 2x60 delivery


List of items of the Flexi RRH 2x60 (FHDB, FHEB, FHEF, and FHEG) delivery.
The Flexi RRH 2TX (FHDB, FHEB, FHEF, and FHEG)
The Flexi Remote Radio Head 2TX (FHDB, FHEB, FHEF, and FHEG) delivery contains:
• Remote Radio Head (FHDB, FHEB, FHEF or FHEG)
• 1 x Lower Mounting Bracket
• 2 x M8x20 Torx screw
• 2 x M5x12 Torx screw
• 2 x Optical Cable Clamps
• 1 x DC Terminal Seal
• 7 x cable ties
• 1 x ground cable (FHDB A.102/FHEB A.102/FHEF A.101/FHEG A.101 and earlier,
removed for FHDB A.103/FHEB A.103/FHEF A.102/FHEG A.102)

2.3 Contents of the Release 4 RRH delivery


List of items of the Release 4 RRH delivery.
The Flexi RRH 2TX/4TX
The Flexi RRH 2TX (FRGY, FRAA, FRCC, FRCG, FRBE, and FRBG) and Flexi RRH
4TX (FHFB, FRBF, FRHG, FHEH, and FHED) delivery contains:
• Remote Radio Head (FRGY, FRAA, FRCC, FRCG, FHFB, FRBE, FRBF, FRBG,
FRHG, FHEH or FHED)
• 1 x Lower Mounting Bracket
• 2 x M8x20 Hexagonal Screw
• 3 x M5x12 Torx Screw
• 3 x Optical Cable Clamps 3
• 1 x DC Terminal Seal
• 1 x DC Cable Clamp
• 7 x cable ties
The Flexi RRH 4-pipe 2300 120W (FRNC)

• Remote Radio Head (FRNC)
• 1 x Lower Mounting Bracket
• 2 x M8x20 Hexagonal Screw
• 3 x M5x12 Torx Screw
• 3 x Optical Cable Clamps 3

Issue: 06A DN09185846 17
   

Unpacking Flexi Multiradio RRH delivery Installing and Cabling Flexi Multiradio Remote Radio
Heads

• 1 x Optical Cable Boot
• 1 x DC Connector
• 1 x DC Cable Clamp
• 7 x Cable Ties

Table 2 Allowed cable diameters
Element Code
473789A FMNA Fiber cable IP boot
Allowed cable diameter is 4.5 to 9 mm

473790A FMNB 2 way DC Input Cable connector
Allowed DC cable diameter is 7 to 17mm
Allowed cross-section is 1-10 mm2 (17-8 AWG)

2.4 Contents of the Flexi RRH 2-pipe 700/840 100W


(FHPC) delivery
List of items of the Flexi Remote Radio Head 2-pipe 700/840 100W (FHPC) delivery.
The Flexi Remote Radio Head 2-pipe 700/840 100W (FHPC) delivery contains only
FHPC Remote Radio Head module.

2.5 Contents of the Flexi RRH 4TX 2100 (FRIG and


FHGB) delivery
List of items of the Flexi RRH 4TX 2100 (FRIG and FHGB) delivery.

The Flexi RRH 4TX 2100 (FRIG and FHGB) delivery contains:

• Remote Radio Head (FRIG or FHGB)
• 1 x IP boot for the DC cable
• 1 x grounding cable
• 3 x strain relief clamps for optical cables
• 1 x cable clamp to secure the DC cable
• 2 x M5x12 screw
• 7 x cable ties

2.6 Contents of the Flexi Pole Mounting Kit (FPKA)


delivery
List of items of the Flexi Pole Mounting Kit (FPKA) delivery.

18 DN09185846 Issue: 06A
   

Installing and Cabling Flexi Multiradio Remote Radio Unpacking Flexi Multiradio RRH delivery
Heads

The Flexi pole mounting kit (FPKA) is designed for poles between 30 mm (1.2 in.) and
120 mm (4.7 in.).
Table 3 The Flexi pole mounting kit (FPKA) delivery content

Description Quantity

Flexi Pole Mounting Kit (FPKA) 1
(472821A)

Aluminum castings 2

Assembling bolts 2

Module fixing screws 6

Bolt restrainer 2

Flexi pole mounting kit (FPKA) shows the FPKA including all of the additional delivery
contents.
Figure 1 Flexi pole mounting kit (FPKA)

BoltM8x20

Fixingpoints
64mm(2.5in.)

Fixingpoints BoltM10X120
184mm(7.2in.) 105mmthread

2.7 Contents of the Flexi Pole Kit (FPKC) delivery


List of items of the Flexi Pole Kit (FPKC) delivery.

The Flexi pole kit (FPKC) is designed for poles between 60 mm (2.4 in.) and 300 mm
(4.7 in.).

Issue: 06A DN09185846 19
   

Unpacking Flexi Multiradio RRH delivery Installing and Cabling Flexi Multiradio Remote Radio
Heads

Table 4 The Flexi pole kit (FPKC) delivery content

Description Quantity

Flexi Pole Kit (FPKC), (472821A) 1

FPKC Bracket 2

FMFA Rodent Block Plate 1

Stud Grounding Press Stud (ESD) 1

M8x30 hexagonal screws with nuts 5

M10x315 hexagonal screws 2

M5x12 screws 8

M8x20 hexagonal screws 5

2.8 Contents of the mounting bracket for pole (FMFC)


delivery
List of items of the mounting bracket for pole (FMFC) delivery.

The FMFC Mounting Bracket delivery contains only FMFC Mounting Bracket.

2.9 Contents of the pole mounting kit (VMPB) delivery


List of items of the pole mounting kit (VMPB) delivery.

The pole mounting kit (VMPB) is an optional item that can be ordered separately, if
needed.
The figure Contents of the pole mounting kit (VMPB) delivery presents the contents of
the pole mounting kit delivery.

20 DN09185846 Issue: 06A
   

Installing and Cabling Flexi Multiradio Remote Radio Unpacking Flexi Multiradio RRH delivery
Heads

Figure 2 Contents of the pole mounting kit (VMPB) delivery

2.10 Contents of the mounting kit for floor, wall and pole
(FMFA) delivery
List of items of the mounting kit for floor, wall and pole (FMFA) delivery.

The FMFA mounting kit is an optional item that has to be ordered separately, if needed.
The FMFA delivery contains:
• Mounting kit for floor, wall and pole
• 2 pcs fixing plate for the casing
• 12 pcs M5x8 screws
• 2 pcs M5x12 screws

See the following figure for more information on FMFA delivery contents.

Issue: 06A DN09185846 21
   

Unpacking Flexi Multiradio RRH delivery Installing and Cabling Flexi Multiradio Remote Radio
Heads

Figure 3 Delivery contents of FMFA

12pcsM5x8
2pcsM8x12

22 DN09185846 Issue: 06A
   

Installing and Cabling Flexi Multiradio Remote Radio Installation tools and torque values
Heads

3 Installation tools and torque values

3.1 BTS installation tools and equipment


List of needed installation tools and equipment.

This section lists the installation tools and equipment.
Table 5 Tools for installation

Installation tools

Allen key: 8 mm

Allen key: 6 mm

Allen key: 3 mm

Allen key: 2.5 mm

ESD wrist strap and cable

TORX screwdriver set: T10, T20, T25, T45

Screwdriver set: Phillips 0 , 1, 2 and flathead

Wrench 13 mm (0.51 in.)

Folding knife

Monkey wrench

Side cutters

Scissors

Hose clamps

Crimping tool for 16 mm² grounding cable

Torque wrench for antenna cables

Lint-free swab or wipe and 99% alcohol for cleaning optical connectors

Cable ties for routing cables

Tape measure

Flashlight, pocket lamp or torch

Issue: 06A DN09185846 23
   

Installation tools and torque values Installing and Cabling Flexi Multiradio Remote Radio
Heads

Table 5 Tools for installation (Cont.)

Installation tools

Hammer drill

Marker pen or comparable tool

Pliers

Saw

Lubricant for cables

3.2 Torque values


Table with torque values for the BTS recommended by Nokia.

Nokia strongly recommends the following torque values for the various different bolts and
screws (assuming that lubricant has been applied). Use these values unless stated
otherwise.
For the torque values of the DC connector and its IP boot, refer to installation
instructions.

Table 6 Torque values for the BTS

Bolt/Screw Type DIN Size Torque

TORX head screw 7985 F1-60 M3 0.7 - 1.0 Nm


cylinder head
(0.52 - 0.74 ft-lb)

TORX head screw 7985 F1-60 M4 1.2 - 1.6 Nm


cylinder head
(0.89 - 1.18 ft-lb)

TORX head screw 7985 F1-60 M5 2.0 - 5 Nm


cylinder head
(1.47 - 3.7 ft-lb.)

TORX head PT 5x10 WN1452 5x10 mm 2.0 Nm (1.48 ft-lb)


mm
TORX head screw 7985 F1-60 M8 20.0 Nm
cylinder head
(14.75 ft-lb)

Hexagon head screw 933-12-70 M12 49.0 Nm


(cabinet fixing)
(36.14 ft-lb)

24 DN09185846 Issue: 06A
   

Installing and Cabling Flexi Multiradio Remote Radio Installation tools and torque values
Heads

Table 6 Torque values for the BTS (Cont.)

Bolt/Screw Type DIN Size Torque

Allen screw 912-A2-70 M8 8.0 - 10.0 Nm


(5.90 - 7.38 ft-lb)

Nut 934 A2 M5 3.7 Nm


(2.73 ft-lb)

Nut (cabinet fixing) 934 A2 M12 49.0 Nm


(36.14 ft-lb)

FPKA/FPKC screw 933 M8x20 20.0 Nm (14.75 ft-


lb)

Release 4 Mounting 933 M8x20 20.0 Nm (14.75 ft-


Bracket lb)

Fan fixing screws, -NA- M4 0.7 Nm


plastic
(0.52 ft-lb)

Fan fixing screws, -NA- M4 1.2 Nm


metal
(0.89 ft-lb)

Issue: 06A DN09185846 25
   

Before you start Installing and Cabling Flexi Multiradio Remote Radio
Heads

4 Before you start


Important precautions and initial information on installing RRH.

The installation pictures show how a Single RRH is set-up and configured.

g Note: Do not paint over the plastic cover as extra layers of paint can cause cooling
problems. Ensure the RRH solar shield or plastic cover is in the standard issue color for
guaranteed optimum performance.

Consider the following guidelines before installing the RRH module:

• The RRH module is designed to be installed in a vertical position.
• Up to three RRH Modules can be fitted onto one FPKA (excluding
FRIG/FRHE/FRHD/FHPC).
• Up to two RRH Modules can be installed onto one VMPB or FPKC. FPKC kits can be
expanded to support up to 6 RRHs.
• If an FMFA is already installed using a pole mounting kit, only one 2x40 W RRH
module can be installed using the same pole mounting kit.
• If two FMFAs are installed using a pole mounting kit, 2x40 W RRH cannot be
installed using the same pole mounting kit.
• A 2x60 W RRH can be installed next to FMFA on FPKA. Requires FMFA to be
installed on front face of FPKA.
• FPKA enables the FPAD/E to be installed behind the RRH when FPKC is connected.
The FPKC can only be mounted behind the RRH when the FPKC is connected to a
further FPKC. Expansion brackets need to be installed/fixed/ applied onto the side of
the FPKC in order to allow more than two RRHs to be mounted onto a pole.
• Up to one 2x60 W RRHs or one 4x40 W RRHs can be installed with one FMFA on
the same FPKA.
• Angle or straight lugs can be used for ground cabling.
• Optical cables can be straight or angled.
• Antenna cables must be rated IP65.

The TORX screw driver sizes required for RRH installation are T10 (DC cable clamp),
T45 (M8 grounding interface), and T25 (all M5 screws).

g Note: Do not install RRH modules inside an enclosed space without proper ventilation
or climate control, as the module is cooled by convection.

g Note: If RET is used, consider the length of the RET and the antenna jumper cables
and their physical path to the antenna tilt meter when choosing an installation location
on the pole. All cables connecting to the interfaces above the RRH should be routed
down below the RRH and then looped up to help prevent water ingress. The loop must
not exceed the minimum bending radius specified by the manufacturer.

w NOTICE:  Risk of damage to equipment. Optical fibers are sensitive and therefore must
be kept clear of contaminants which lower the mechanical strength of the optical fiber,
possibly dampening the transmission of the light in the fibers. Clean all optical fiber
connectors before installation using an optical fiber connector cleaning kit.

26 DN09185846 Issue: 06A
   

Installing and Cabling Flexi Multiradio Remote Radio Before you start
Heads

f CAUTION! Risk of personal injury.


When operating in hot environments the unit's surfaces might be very hot.
IEC/UL 60950-1 safety compliance requires installation in a restricted access location
so that the unit's hot surface cannot be touched unintentionally.

w NOTICE:  Risk of damage to equipment. Incorrect cables and seals do not offer
optimum protection against extreme weather conditions. Only use tested IP65 class
outdoor cables with seals provided by Nokia for outdoor installations.

w NOTICE:  Risk of damage to equipment. Overbending optical fiber cables can damage
the cables and can detach or damage the connectors. Do not exceed the minimum
bending radius of 70 mm (2.76 inches) for optical cables with a diameter 7 mm (0.28
inches) or 50 mm (1.97 inches) for optical cables with a diameter 5 mm (0.20 inches).

w NOTICE:  Risk of damage to equipment. Remote Radio Head uses convection cooling.
To avoid module overheating, cables should be routed so they do not block airflow
through the cooling fins. Never route cables between cooling fins.

Issue: 06A DN09185846 27
   

Dimension guidelines for wall and pole mounting Installing and Cabling Flexi Multiradio Remote Radio
Heads

5 Dimension guidelines for wall and pole


mounting
Information on dimensions for wall and pole mounting of Flexi 2x40 and 2x60 RRH
modules.

g Note: For guidelines for the Release 4 RRH, see:
Installing and cabling RRH Release 4 onto a pole.
Dimension guidelines for installations onto poles
RRH mounting kit brackets can be fixed to longer or shorter dimensions according to site
specifications. To install RRH mounting kit, see: Installing Flexi 2x40 W RRH on the pole
next to FMFA. The following illustrations provide guidelines for using these dimensions.

g Note: The minimum spacing (392.5 mm) is required only when installing the 2x60W
RRH onto the same pole kit or fixing rails as the legacy RRH with 392.5 mm vertical
spacing. Use 482.5 mm (19 in) or longer spacing when mounting the FPAD onto the
back of the RRH during FPKA installations.

Figure 4 Dimension guidelines for installations onto poles (2x40 W RRH)
For 2x40WRRHonly onFPKA/FPKC, For 2x40WRRHandFMFA onthesame
usethelongerdimensionsbetweenupperand FPKA/FPKC,useshorterdimensions
lowerFPKA/FPKC brackets. betweenupperandlowerFPKA/FPKC
brackets.
FlexiModule
482.5mm
532mm

FMF A

2x40W 2x40W 2x40W


RRH RRH RRH

FPKA
Fixing
Fixing FPKC bracket
Antenna bracket
FPKA Pole Antenna
Pole
FPKC

28 DN09185846 Issue: 06A
   

Installing and Cabling Flexi Multiradio Remote Radio Dimension guidelines for wall and pole mounting
Heads

Figure 5 2x60 RRH Spacing

g Note: The 392.5 mm (15.45 in) spacing applies only to FHDB, FHEB, and FHEG
modules.

Figure 6 Dimension guidelines for installations onto poles (2x60 W RRH)
Fora 2x60WRRH onthesameFPKA/VMPB Fora 2x60WRRH andFMF A inthesame
asa 2x40WRRH (installedwith532mmdimensions), FPKA/VMPB,usethe"FMF A"dimensions
usethe"AL T"dimensionsgivenonthefixingbrackets. givenonthefixingbrackets.

FlexiModule
482.5mm
532mm

FMF A

2x40W 2x60W 2x60W


RRH RRH RRH

FPKA
Fixing
Fixing
bracket
Antenna bracket
Antenna
Pole Pole
FPKA
Dimension guidelines for installations onto walls

Issue: 06A DN09185846 29
   

Dimension guidelines for wall and pole mounting Installing and Cabling Flexi Multiradio Remote Radio
Heads

Figure 7 Dimension guidelines for installations onto walls (2x40 W RRH)

g Note: The dimensions in the figure also apply to FRGQ, FRLB, 4x30 W RRH, and
FHCA modules.
For 2x40WRRHonly onawall For 2x40WRRHandFMFA onthesameset
usethelongerdimensions offixingrails useshorterdimensions

FMF A

482.5mm
532mm
Fixing Fixing
2x40WRRH 2x40WRRH FlexiModule 2x40WRRH
RRH
RRH
rails rails

Fixing
bracket

Figure 8 Dimension guidelines for installations onto walls (2x60 W RRH)
Fora 2x60WRRH onthesamefixingrails
asa 2x40WRRH (installedwith532mm For 2x60WRRH and FMF A onthesamesetof
dimensions),usethe532 dimensionsgiven fixingrails,usethe482.5dimensions.
onthefixingbrackets.

FMF A
482.5mm
532mm

Fixing Fixing
2x60WRRH 2x60WRRH FlexiModule 2x60WRRH
RRH
RRH
rails rails

Fixing
bracket

30 DN09185846 Issue: 06A
   

Installing and Cabling Flexi Multiradio Remote Radio Installing and cabling Flexi 2x40 W RRH onto a pole
Heads

6 Installing and cabling Flexi 2x40 W RRH onto


a pole
These instructions show the installation and cabling procedure for the Flexi 2x40 W
Remote Radio Head onto a pole.

Purpose
The RRH 2TX variant shown in the figures is Flexi RRH 2TX 800EU (FRMB). The order
of the interfaces under to RRH can vary between Flexi RRH 2TX variants, however,
these instructions apply to all variants.
The Flexi 2x40 W RRH interfaces are shown in the following diagram.

Figure 9 FRGQ interfaces
ANT2 RXO2 RXO1 ANT1 RET

EAC LMP OPT2 OPT1 DCIN

Issue: 06A DN09185846 31
   

Installing and cabling Flexi 2x40 W RRH onto a pole Installing and Cabling Flexi Multiradio Remote Radio
Heads

Figure 10 FRMB, FRHB, FHEA, and FHDA interfaces
ANT2 RET ANT1

Grounding
points DCINPUT OPT2 OPT1
EAC
MOD Tx
(LEDModulestatus) (LED Txstatus)
Before you start

f CAUTION! Risk of personal injury.


When operating in hot environments the unit's surfaces might be very hot.
IEC/UL 60950-1 safety compliance requires installation in a restricted access location
so that the unit's hot surface cannot be touched unintentionally.

Procedure

1 Install Flexi Pole Mounting Kit (FPKA) as instructed in Installing Flexi Pole
Mounting Kit (FPKA).

2 Release the strain relief by undoing the screw.


Reserve the screw for later use.

32 DN09185846 Issue: 06A
   

Installing and Cabling Flexi Multiradio Remote Radio Installing and cabling Flexi 2x40 W RRH onto a pole
Heads

Figure 11 Releasing strain relief

3 Fix the two screws on the strain relief.

Figure 12 Releasing strain relief

Issue: 06A DN09185846 33
   

Installing and cabling Flexi 2x40 W RRH onto a pole Installing and Cabling Flexi Multiradio Remote Radio
Heads

4 Lift the module RRH onto the upper part of the FPKA bracket and tighten the
M8 bolts to 20 Nm (14.75 ft-lb.). Use the lifting point.

w NOTICE:  Do not lift the RRH onto a pole by the handle. Use the lifting point instead.
This does not concern FRGY. For FRGY lifting point is part of the handle.

w NOTICE: Use a rope which is strong enough to support the module.

w NOTICE: Do not remove the lifting rope until the RRH is secured to the FPKA bracket.

f CAUTION! Risk of personal injury.


Take care when lifting the Remote Radio Head as it is very heavy.

Figure 13 Fixing the upper screws to the FPKA bracket

Liftingpoint

34 DN09185846 Issue: 06A
   

Installing and Cabling Flexi Multiradio Remote Radio Installing and cabling Flexi 2x40 W RRH onto a pole
Heads

5 Apply the lower screws to the FPKA lower bracket to 30 Nm (22.12 ft-lb.).

Figure 14 Applying the lower screws to the FPKA

6 Tighten the fixing bolts to 20 Nm (14.75 ft-lb).

7 Attach the DC cable clamp on the strain relief.

Figure 15 Attaching DC cable clamp

Issue: 06A DN09185846 35
   

Installing and cabling Flexi 2x40 W RRH onto a pole Installing and Cabling Flexi Multiradio Remote Radio
Heads

8 Connect the grounding cable.

Figure 16 Connecting grounding cable

9 Connect the DC power cable.

a) Strip about 10 cm (4 in) of the DC cable and wrap some tape around the GND
mesh and the cable sheath neck.
Figure 17 Wrapping tape around shielded DC cable

b) Wrap extra tape around the exposed wires to prevent to IP from breaking..
Figure 18 Wrapping extra tape around the DC cable

36 DN09185846 Issue: 06A
   

Installing and Cabling Flexi Multiradio Remote Radio Installing and cabling Flexi 2x40 W RRH onto a pole
Heads

c) Insert the taped end of the DC feeder cable into the IP boot.
Figure 19 Inserting DC power cable into an IP boot

When using a thick cable, the narrow end of the IP boot can be removed using
scissors. Use a single cut to ensure a clean cut surface. For details, see Figure
20: Removing narrow end of an IP boot for details. The cable diameter cannot be
wider than 25 mm (1 in.) or be narrower than 6 mm (0.24 in.).

w NOTICE:  The IP boot edge must be smooth. Ensure there are no cracks present in the
edge, as it compromises boot IP protection.

Issue: 06A DN09185846 37
   

Installing and cabling Flexi 2x40 W RRH onto a pole Installing and Cabling Flexi Multiradio Remote Radio
Heads

Figure 20 Removing narrow end of an IP boot

Cablediameter 20.1 -25.0 mm


cutwithscissorsinonego

Cablediameter15.1 -20.0 mm
cutwithscissorsinonego

Cablediameter10.1 - 15.0 mm
cutwithscissorsinonego

Cablediameter 6.0 - 10.0 mm


(nocuttingneed)

d) Remove the extra tape from DC cable.

g Note: Keep the tape around the GND mesh and cable sheath neck to protect an IP
boot from sharp edges.

38 DN09185846 Issue: 06A
   

Installing and Cabling Flexi Multiradio Remote Radio Installing and cabling Flexi 2x40 W RRH onto a pole
Heads

Figure 21 Properly secured shielded DC cable (left) and non-shielded DC
cable (right)

e) Connect the wires to the screw terminal and tighten to 3.0 Nm (26.55 in-lb.).
Figure 22 Connecting DC feeder cable wires

GND -
+

f) Fix the IP boot in place and tighten the screw to max 2.0 (17.7 in-lb.).

Issue: 06A DN09185846 39
   

Installing and cabling Flexi 2x40 W RRH onto a pole Installing and Cabling Flexi Multiradio Remote Radio
Heads

g Note: On sites where birds or rodents are a concern, it is recommended that exposed
cables and DC terminal seals be protected with conduit. Use any suitable standard
conduit for that purpose. Make sure that the conduit is securely locked in position as
close to the IP seals as possible.

Figure 23 Example of conduit usage

g) Secure the cable in place with the cable clamp.
Figure 24 Fixing DC cable clamp

10 Connect the antenna cables and tighten them to 25 Nm (18.44 ft-lb).

w NOTICE:  When using a large torque wrench to tighten the cable connections, be
careful not to damage any of the other smaller connectors.

40 DN09185846 Issue: 06A
   

Installing and Cabling Flexi Multiradio Remote Radio Installing and cabling Flexi 2x40 W RRH onto a pole
Heads

Figure 25 Connecting antenna cables

11 Remove the shipping cap from RET connector.

12 If applicable, connect the RET cable.


Push the cable all the way down into the connector on the RRH front panel and then
twist it. Tighten to max 0.5 - 1.0 Nm (0.37 - 0.74 ft-lb). Only hand-tightening is
allowed.
If no RET cable is connected, place the shipping cap back onto the RET connector.

Figure 26 Connecting RET cable

13 Connect the optical cables and secure them using cable clamps.
Straight optical cables are recommended. Do not exceed minimum bending radius of
70 mm (2.76 inches) for cables with diameter 7 mm (0.28 inches) or 50 mm (1.97
inches) for cables with diameter 5 mm (0.20 inches).

Issue: 06A DN09185846 41
   

Installing and cabling Flexi 2x40 W RRH onto a pole Installing and Cabling Flexi Multiradio Remote Radio
Heads

Figure 27 Connecting optical cables

14 If applicable, connect the EAC cable.


For further details, see Flexi RRH 2TX external alarm connection.

Figure 28 Connecting EAC cable

15 If applicable, connect the RX out cables.

Figure 29 Connecting RX out cable

42 DN09185846 Issue: 06A
   

Installing and Cabling Flexi Multiradio Remote Radio Installing and cabling Flexi 2x40 W RRH onto a pole
Heads

16 If applicable, connect the LMP cable.

Figure 30 Connecting LMP cable

17 Secure all cables with cable ties.

Figure 31 Securing cables with cable ties

Issue: 06A DN09185846 43
   

Installing and cabling Flexi 2x60 W RRH onto a pole Installing and Cabling Flexi Multiradio Remote Radio
Heads

7 Installing and cabling Flexi 2x60 W RRH onto


a pole
These instructions show the installation and cabling procedure for the Flexi 2x60 W
Remote Radio Head (FHDB A.103/FHEB A.103/FHEF A.102/FHEG A.102 and later)
onto a pole.

Before you start

g Note: For FHDB A.102/FHEB A.102/FHEF A.101/FHEG A.101 and earlier, see Issue 5
of this document.

The Flexi 2x60 W RRH interfaces are shown in the following diagram.

Figure 32 FHDB, FHEB, FHEF, and FHEG interfaces
LED OPT2 OPT1 EAC

ANT2 RET DCIN ANT1

44 DN09185846 Issue: 06A
   

Installing and Cabling Flexi Multiradio Remote Radio Installing and cabling Flexi 2x60 W RRH onto a pole
Heads

Figure 33 Lower fixing bracket of 2x60 W RRH

G
G

F F

H
E
E
D
C
C
B
A H
A Standard cable fixing plane
B 45° cable fixing plane
C Mounting to pole or wall (532 mm spacing)
D Optical cable clamp interfaces
E Mounting to pole or wall (482.5 mm spacing)
F Mounting to pole or wall (392.5 mm spacing)
G Module mounting
H DC cable clamp interfaces

g Note: The module is delivered with the upper bracket pre-installed.
For dimension guidelines for 2x60 RRH installation onto walls and poles, see Dimension
guidelines for wall and pole mounting.

Procedure

1 Install Flexi Pole Mounting Kit (FPKA) or VMPB.


See: Mounting the plinth on a pole.

2 Install the lower fixing bracket.

a) Place the RRH upside down.

Issue: 06A DN09185846 45
   

Installing and cabling Flexi 2x60 W RRH onto a pole Installing and Cabling Flexi Multiradio Remote Radio
Heads

Figure 34 Placing the RRH upside down (2x60 W RRH)

b) Align the M8 screw holes on the fixing bracket with the RRH.
Figure 35 Aligning lower fixing bracket

c) Tighten the two M8 screw holes to 20 Nm (14.8 ft-lb).

3 Attach the DC cable clamp onto the strain relief.


The cable clamp might be screwed in one of the positions as shown in the Figure 36:
Attaching DC cable clamp (2x60 W RRH).

46 DN09185846 Issue: 06A
   

Installing and Cabling Flexi Multiradio Remote Radio Installing and cabling Flexi 2x60 W RRH onto a pole
Heads

Figure 36 Attaching DC cable clamp (2x60 W RRH)

4 Lift the RRH onto the pole using the lifting point.

w NOTICE: Take care when lifting the Remote Radio Head as it is very heavy.

w NOTICE: Use a rope which is strong enough to support the module.

Figure 37 Lifting RRH onto a pole

Issue: 06A DN09185846 47
   

Installing and cabling Flexi 2x60 W RRH onto a pole Installing and Cabling Flexi Multiradio Remote Radio
Heads

5 Tighten the four M8 screws to 20 Nm (14.8 ft-lb).

6 Connect the grounding cable.


Install the grounding cable according to local standards. For example, use M8 torx
screw in Europe and 2 x M5 screw in USA.

Figure 38 Connecting grounding cable (2x60 W RRH)
Groundingpoint
M8 M5

7 Connect the DC power cable.


Sub-steps

a) Remove the DC protective cover.

Figure 39 Removing the DC protective cover (2x60 W RRH)

b) Reserve DC protective cover for later use.


Place the cover on the back of the bracket, as shown in Figure 40: Removing
and reserving DC protective cover.

48 DN09185846 Issue: 06A
   

Installing and Cabling Flexi Multiradio Remote Radio Installing and cabling Flexi 2x60 W RRH onto a pole
Heads

Figure 40 Removing and reserving DC protective cover

c) Strip 7 cm (2.75 in.) off the outer jacket of the DC cable and wrap tape
around the exposed wires to avoid breaking the IP boot.

Figure 41 Wrapping tape around DC cable

Issue: 06A DN09185846 49
   

Installing and cabling Flexi 2x60 W RRH onto a pole Installing and Cabling Flexi Multiradio Remote Radio
Heads

d) Insert the taped end of the DC feeder cable to the IP boot and feed it
through.

Figure 42 Inserting DC feeder cable to an IP boot

When using a thick cable, the narrow end of the IP boot can be removed using
scissors. Hold the IP boot at the rigid part and twist the end so that it comes off.

50 DN09185846 Issue: 06A
   

Installing and Cabling Flexi Multiradio Remote Radio Installing and cabling Flexi 2x60 W RRH onto a pole
Heads

Figure 43 Removing narrow end of an IP boot

Cablediameter 20.1 -25.0 mm


cutwithscissorsinonego

Cablediameter15.1 -20.0 mm
cutwithscissorsinonego

Cablediameter10.1 - 15.0 mm
cutwithscissorsinonego

Cablediameter 6.0 - 10.0 mm


(nocuttingneed)

e) Remove the tape.

f) Strip 12 mm (0.47 in.) off the + and - wires and connect those wires to the +
and - screw terminals. Tighten to 3.0 Nm (26.55 in-lb).

t Tip: The square metal plate secures the cable against a fixture. To avoid it from
falling out, do not remove the screw completely when loosening to connect the
power supply. Instead, apply slight pressure to the screw so that metal plate
creates an opening for the cable.

Issue: 06A DN09185846 51
   

Installing and cabling Flexi 2x60 W RRH onto a pole Installing and Cabling Flexi Multiradio Remote Radio
Heads

Figure 44 Connecting wires to screw terminals (2x60 W RRH)

GND -
+

+ -

g) If a shielded cable is used, connect the cable braid or ground wire to the
middle screw terminal. Tighten to 3.0 Nm (26.55 in-lb).

Figure 45 Connecting braid to the middle screw terminal (2x60 W RRH)

GND -
+

Middlescrewterminal

52 DN09185846 Issue: 06A
   

Installing and Cabling Flexi Multiradio Remote Radio Installing and cabling Flexi 2x60 W RRH onto a pole
Heads

h) Secure a tie wrap around the end of the IP boot to complete IP65
protection.

i) Apply the IP boot in place and fix the screw to max 2.0 Nm (17.07 in-lb).

Figure 46 Fixing the IP boot (2x60 W RRH)

g Note: On sites where birds or rodents are a concern, it is recommended that
exposed cables and DC terminal seals be protected with conduit. Use any
suitable standard conduit for that purpose. Make sure that the conduit is securely
locked in position as close to the IP seals as possible.

Figure 47 Example of conduit usage

Issue: 06A DN09185846 53
   

Installing and cabling Flexi 2x60 W RRH onto a pole Installing and Cabling Flexi Multiradio Remote Radio
Heads

j) Tighten the clamp to 0.5 Nm (4.4 in-lb.) and secure the cable in place with
the cable clamp.

Figure 48 Securing the cable with the cable clamp (2x60 W RRH)

8 If applicable, connect the RET cable.

Figure 49 Connecting the RET cable (2x60 W RRH)

9 Connect the antenna cables.


Tighten the connector with a torque wrench to 25.0 Nm (18.5 ft-lb).

54 DN09185846 Issue: 06A
   

Installing and Cabling Flexi Multiradio Remote Radio Installing and cabling Flexi 2x60 W RRH onto a pole
Heads

Figure 50 Connecting antenna cables (2x60 W RRH)

10 If applicable, connect the EAC cable.

Figure 51 Connecting the EAC cable (2x60 W RRH)

11 Connect the optical transceivers and cables.


For instructions on connecting the optical transceiver and cable, see Connecting
Optical Cables. Note that port OPT 1 is used for System Module or RRH chaining
and OPT 2 is used for RRH chaining.

Figure 52 Connecting optical transceiver and cable (2x60 W RRH)

Issue: 06A DN09185846 55
   

Installing and cabling Flexi 2x60 W RRH onto a pole Installing and Cabling Flexi Multiradio Remote Radio
Heads

12 Secure all cables with cable ties or clamps.

w NOTICE:  Risk of damage to equipment. Do not overbend cables. The minimum
bending diameter for the cables is listed in the Appendix Bending diameter for cables.

56 DN09185846 Issue: 06A
   

Installing and Cabling Flexi Multiradio Remote Radio Installing and cabling RRH Release 4 onto a pole
Heads

8 Installing and cabling RRH Release 4 onto a


pole
These instructions show the installation and cabling procedure for the Release 4 Remote
Radio Heads onto a pole.

Purpose
This document describes RRH installation without FPAD/E. For FPAD/E installation
instructions, see Installing Flexi Multiradio Base Station and Flexi Multiradio 10 Base
Station Optional Items.
The lower mounting bracket interfaces and cable fixing plates are shown in the Figure
56: Lower mounting bracket of RRH Release 4.
The images in the following instruction show FRGY RRH module, but the installation
order applies to all Release 4 modules listed in the introduction.

f CAUTION! Risk of personal injury.


The plastic cover is always required for Release 4 RRH during indoor and outdoor
operation for IEC/UL 60950-1 safety compliance.

The RRH Release 4 interfaces are shown in the following diagrams.

Figure 53 FRGY and FRAA interfaces

DCIN OPT2 OPT1 RXO2 RXO1

GND ANT2 RET EAC ANT1

Issue: 06A DN09185846 57
   

Installing and cabling RRH Release 4 onto a pole Installing and Cabling Flexi Multiradio Remote Radio
Heads

Figure 54 FRCC and FRCG interfaces
OPT1
OPT2 RXO2
DCIN EAC
RET RXO1

GND

ANT4 ANT1
Figure 55 FHFB, FRBE, FRBF, FRBG, FRNC, FRHG, FHEH, and FHED interfaces
OPT1
CHAIN/EXT OPT2 RXO2
RET DCIN EAC RXO1

GND

ANT4TX ANT3TX ANT2TX/RX ANT1TX/RX


B29 B29 B13 B13

58 DN09185846 Issue: 06A
   

Installing and Cabling Flexi Multiradio Remote Radio Installing and cabling RRH Release 4 onto a pole
Heads

Before you start

Figure 56 Lower mounting bracket of RRH Release 4

F
F

E
E

D G
D

C
C

B
H
A
I

A 45° cable fixing plane
B Standard cable fixing plane
C Mounting to pole kit or wall (482.5, 532 mm vertical
spacing) for modules defined in
Installing and cabling RRH Release 4 onto a pole.
D Module mounting
E Key hole for shoulder bolts/M8 screws (back of a module)
F 4 ANT/FRCC/FRCG mounting to pole kit or wall
(482.5mm, 532mm vertical spacing)
G Mounting to pole kit or wall (392.5 mm vertical spacing) for
modules defined in FRGY and FRAA chapter.
H Optical cable clamp interfaces
I DC cable clamp interfaces

g Note: The module is delivered with the upper bracket pre-installed.

g Note: The strain relief is designed for optical cables with straight ingress protection (IP)
boots (00). For a complete list of Flexi optical cable lengths and types, see
Optional Items Description.

There are three vertical spacing options allowed, shown in the Figure 57: Vertical
spacing options for the RRH Release 4:

Issue: 06A DN09185846 59
   

Installing and cabling RRH Release 4 onto a pole Installing and Cabling Flexi Multiradio Remote Radio
Heads

• 482.5 mm (19 in) - common with FMFA and all legacy RRH variants. Recommended
for all new pole or wall installations or co-siting with legacy modules using this
dimension.
• 532 mm (21 in) – recommended only for co-siting with legacy RRH variants using
this dimension.
• 392.5 mm (15 in) – modules with two antenna connectors only. Recommended for
co-siting with legacy RRH variants using this dimension. FPAC/D mounting on a
RRH is not supported by this dimension.

Figure 57 Vertical spacing options for the RRH Release 4

392.5mm 482.5mm 532mm

g Note: Avoid installing RRH modules inside enclosed spaces without proper ventilation
or climate control, as the modules are cooled by convection.

g Note: If RET is used, consider the length of the RET and the antenna jumper cables
and their physical path to the antenna tilt meter when choosing an installation location
on the pole. All cables connecting to the interfaces above the RRH must be routed
down below the RRH and then looped up to help prevent water ingress. The loop must
not exceed the minimum bending radius specified by the manufacturer.

w NOTICE:  Risk of damage to equipment. Optical fibers are sensitive and therefore must
be kept clear of contaminants which lower the mechanical strength of the optical fiber,
possibly dampening the transmission of the light in the fibers. Clean all optical fiber
connectors before installation using an optical fiber connector cleaning kit.

w NOTICE:  Risk of damage to equipment. Incorrect cables do not offer optimum
protection against extreme weather conditions. Only use tested IP65 class outdoor
cables with seals provided by Nokia for outdoor installations.

60 DN09185846 Issue: 06A
   

Installing and Cabling Flexi Multiradio Remote Radio Installing and cabling RRH Release 4 onto a pole
Heads

w NOTICE:  Risk of damage to equipment. Overbending the optical fiber cables can
damage the cables and can detach or damage the connectors. Do not exceed the
minimum bending radius of 70 mm (2.76 inches) for optical cables with a diameter 7
mm (0.28 inches) or 50 mm (1.97 inches) for optical cables with a diameter 5 mm (0.20
inches).

w NOTICE:  Risk of damage to equipment. Remote Radio Head uses convection cooling.
To avoid module overheating, cables should be routed so they do not block airflow
through the cooling fins. Never route cables between cooling fins.

Release 4 RRH installation requires the following driver sizes. For a complete list of
required tools, see BTS installation tools and equipment.
Table 7 Installation tools
Required tool
Torque wrench capable of 10-30 Nm (7.4 - 22.1 ft-lb) with extensions
Torque screw driver capable of 0.8-5 Nm (7-44 in-lbs.)
TORX screw driver sizes are T10 (DC cable clamp), T45 for M8 ground screw (not required for
dual M5/NEBS ground screws), and T25 (M5 screws)
Hexagonal socket size is 13 mm (1/2 in)
Allen driver size for FPKA/C is 8 mm (5/16 in)

g Note: If you are expanding a FPKC beyond two kits, then a 6 mm (1/4 in) Allen screw
driver is required.

For front panel interfaces, see Flexi Multiradio BTS Radio Module and Remote Radio
Head Description.

Procedure

1 Install the lower fixing bracket on the RRH.

w NOTICE:  Before installing the 4 ANT/FRCC/FRCG module onto the RRH, preassemble
the lower pole bracket (FPKA or FPKC) with the lower fixing bracket, as shown in
Figure 58: Assembling the lower pole bracket with the lower fixing bracket for a FHFB.
For the lower pole bracket installation instructions, see:
Mounting the plinth on a pole with FPKA or . Use a space of 482.5 mm or 532 mm
vertically for the 4 ANT/FRCC/FRCG, as shown in
Figure 56: Lower mounting bracket of RRH Release 4.
Note that if you are installing an 4 ANT/FRCC/FRCG onto an existing FPKA/FPKC, the
lower mounting bracket should be preinstalled on the lower FPKA/FPKC bracket.

Issue: 06A DN09185846 61
   

Installing and cabling RRH Release 4 onto a pole Installing and Cabling Flexi Multiradio Remote Radio
Heads

Figure 58 Assembling the lower pole bracket with the lower fixing bracket for a
FHFB

Sub-steps

a) Place the RRH so that the plastic cover faces down.

Figure 59 RRH with the plastic cover faced down

62 DN09185846 Issue: 06A
   

Installing and Cabling Flexi Multiradio Remote Radio Installing and cabling RRH Release 4 onto a pole
Heads

b) Attach the DC cable clamp on the lower fixing bracket. Tighten the screws
half way to secure them during lifting.

Figure 60 Attaching a DC clamp

c) Rotate the lower fixing bracket with the cable tie points facing down.

d) Align the key holes on the lower fixing bracket with the M8 TORX alignment
screws on the RRH.

Figure 61 Aligning key holes on the lower fixing bracket

Issue: 06A DN09185846 63
   

Installing and cabling RRH Release 4 onto a pole Installing and Cabling Flexi Multiradio Remote Radio
Heads

e) Slide the lower fixing bracket into place.

Figure 62 Sliding lower bracket into place

f) Apply two M8 hexagonal screws. Tighten to 20 Nm (14.8 ft-lb).

Figure 63 RRH with lower bracket in place

hexagonalscrews

64 DN09185846 Issue: 06A
   

Installing and Cabling Flexi Multiradio Remote Radio Installing and cabling RRH Release 4 onto a pole
Heads

2 Install the Flexi Pole Mounting Kit (FPKA or FPKC). See Mounting the plinth on
a pole with FPKA or Installing Flexi RRH 2TX on the pole with FPKC for
instructions, substituting the RRH with the plinth where applicable.

3 Lift the RRH onto the pole as shown in the Figure 64: Lifting RRH onto a pole.
Use the lifting point.

f CAUTION! Risk of personal injury.


Take care when lifting the Remote Radio Head as it is very heavy.

w NOTICE: Use a rope which is strong enough to support the module.

Figure 64 Lifting RRH onto a pole

Liftingpoint

4 Tighten the four M8 hexagonal screws to 20 Nm (14.8 ft-lb).

5 Connect the grounding cable.

g Note: FRCC and FRCG are 2ANT modules, but they have to follow the 4ANT mounting
pattern. The work order is the same. For details see
Figure 81: Connecting all the cables for FRCC and FRCG.

g Note: Install the grounding cable according to local standards. For example, use M8
bolts in Europe and 2 x M5 bolts in USA. Tighten M8 bolts to 20 Nm (14.75 ft-lb) and
M5 bolts to 4.2 Nm (37 in-lb).

Issue: 06A DN09185846 65
   

Installing and cabling RRH Release 4 onto a pole Installing and Cabling Flexi Multiradio Remote Radio
Heads

Figure 65 Connecting grounding cable (4 ANT)

6 Connect the antenna cables. Tighten the connectors according to the antenna
cable manufacturer instructions.

Figure 66 Connecting antenna cables (4 ANT)

7 Connect the DC cable.


These sub-steps concern connecting the DC cable for Release 4 modules excluding
FRNC. For FRNC DC cable instructions, see Figure 76: Connecting FRNC DC cable.
a) Strip about 10 cm (4 in) of the DC cable and wrap some tape around the GND
mesh and the cable sheath neck.

66 DN09185846 Issue: 06A
   

Installing and Cabling Flexi Multiradio Remote Radio Installing and cabling RRH Release 4 onto a pole
Heads

Figure 67 Wrapping tape around DC cable

b) Wrap extra tape around the exposed wires to prevent to IP from breaking.
Figure 68 Wrapping extra tape around DC cable

c) Insert the taped end of the DC feeder cable into the IP boot and feed it through.

Issue: 06A DN09185846 67
   

Installing and cabling RRH Release 4 onto a pole Installing and Cabling Flexi Multiradio Remote Radio
Heads

Figure 69 Inserting DC power cable into an IP boot

When using a thick cable, the narrow end of the IP boot can be removed using
scissors. Use a single cut to ensure a clean cut surface. For details, see: Figure
70: Removing narrow end of an IP boot. The cable diameter cannot be wider
than 25 mm (1 in) or be narrower than 6 mm (0.24 in).

w NOTICE:  The IP boot edge must be smooth. Ensure there are no cracks present in the
edge, as it compromises IP boot protection.

68 DN09185846 Issue: 06A
   

Installing and Cabling Flexi Multiradio Remote Radio Installing and cabling RRH Release 4 onto a pole
Heads

Figure 70 Removing narrow end of an IP boot

Cablediameter 20.1 -25.0 mm


cutwithscissorsinonego

Cablediameter15.1 -20.0 mm
cutwithscissorsinonego

Cablediameter10.1 - 15.0 mm
cutwithscissorsinonego

Cablediameter 6.0 - 10.0 mm


(nocuttingneed)

d) Remove the extra tape from DC cable.

g Note: Keep the tape around the GND mesh and cable sheath neck to protect IP boot
from sharp edges.

Issue: 06A DN09185846 69
   

Installing and cabling RRH Release 4 onto a pole Installing and Cabling Flexi Multiradio Remote Radio
Heads

Figure 71 Properly secured shielded DC cable (left) and non-shielded DC
cable (right)

e) Connect the wires to the screw terminal and tighten to 3.0 Nm (26.55 in-lb).
Figure 72 Connecting DC feeder cable wires

GND -
+

f) Fix the IP boot in place and tighten the screw to max 2.0 Nm (17.07 in-lb).

70 DN09185846 Issue: 06A
   

Installing and Cabling Flexi Multiradio Remote Radio Installing and cabling RRH Release 4 onto a pole
Heads

g Note: On sites where birds or rodents are a concern, it is recommended that exposed
cables and DC terminal seals be protected with conduit. Use any suitable standard
conduit for that purpose. Make sure that the conduit is securely locked in position as
close to the IP seals as possible.

Figure 73 Example of conduit usage

g) Secure the cable in place with the cable clamp and tighten it to 0.5 Nm (4.43 ft-
lb).
Figure 74 Securing DC cable clamp

For DC feeder cable details, see Feederless site and Distributed site solution
requirements in the Flexi Multiradio BTS WCDMA Installation Site Requirements
document.

8 When installing FRNC, connect DC cable as shown in the Figure 76:


Connecting FRNC DC cable.
Information on DC connector pins:
• A - this is a negative (-) pin
• B - this is a positive (+) pin

Issue: 06A DN09185846 71
   

Installing and cabling RRH Release 4 onto a pole Installing and Cabling Flexi Multiradio Remote Radio
Heads

Figure 75 FRNC DC cable

-
(A)

+
(B)

Figure 76 Connecting FRNC DC cable

72 DN09185846 Issue: 06A
   

Installing and Cabling Flexi Multiradio Remote Radio Installing and cabling RRH Release 4 onto a pole
Heads

9 If applicable, connect the EAC cable.

10 If applicable, connect the RET cable.

Figure 77 Connecting RET and EAC cables (4 ANT)

11 Connect the optical transceivers and cables.

g Note: When cabling FRNC, check the manufacturers instructions for optical cable boot
installation.

Figure 78 Connecting optical cables (4 ANT)

Issue: 06A DN09185846 73
   

Installing and cabling RRH Release 4 onto a pole Installing and Cabling Flexi Multiradio Remote Radio
Heads

12 If applicable, connect the RXO cables.

Figure 79 Connecting RXO cables (4 ANT)

13 Secure all cables with cable ties or clamps.

g Note: Tighten optical cable clamps to 2 Nm (18 in-lb).

Figure 80 Securing cables with ties and clamps

Figure 81 Connecting all the cables for FRCC and FRCG

74 DN09185846 Issue: 06A
   

Installing and Cabling Flexi Multiradio Remote Radio Installing and cabling RRH Release 4 onto a pole
Heads

Result

When installing additional RRH modules onto the same FPKA bracket, follow the
instructions above. Modules must be hung onto existing FPKAs, as shown in Figure 82:
Mounting additional modules onto a pole.

Figure 82 Mounting additional modules onto a pole

Issue: 06A DN09185846 75
   

Installing and cabling Flexi RRH 2TX 730 (FRLB) onto Installing and Cabling Flexi Multiradio Remote Radio
a pole Heads

9 Installing and cabling Flexi RRH 2TX 730


(FRLB) onto a pole
These instructions show the installation and cabling procedure for the Flexi RRH 2TX
730 (FRLB) Remote Radio Heads onto a pole.

Purpose
Use Flexi Pole Mounting Kit (FPKA) for installing Flexi Remote Radio Head 2TX 730
(FRLB) onto a pole. If your FPKA includes both plinth (FMFA) and RRH 2TX
installations, for instructions, see Installing Flexi RRH 2TX on the pole opposite to FMFA.
The FRLB interfaces are shown in the following diagram.

Figure 83 FRLB interfaces
ANT2 RXO2 RET RXO1 ANT1

EAC LMP Ground OPT1 OPT2

Procedure

1 Install the upper FPKA bracket onto the pole as instructed in Installing Flexi
Pole Mounting Kit (FPKA).

2 Release the strain relief by undoing the screw.


Reserve the screw for later use.

76 DN09185846 Issue: 06A
   

Installing and Cabling Flexi Multiradio Remote Radio Installing and cabling Flexi RRH 2TX 730 (FRLB) onto
Heads a pole

Figure 84 Releasing strain relief plate

3 Fix the lower FPKA bracket onto the back of the FRLB.

Figure 85 Fixing FPKA onto FRLB

Issue: 06A DN09185846 77
   

Installing and cabling Flexi RRH 2TX 730 (FRLB) onto Installing and Cabling Flexi Multiradio Remote Radio
a pole Heads

4 Fix the strain relief onto the lower bracket using two M5 screws and tighten
them to 4 Nm (2.95 ft-lb.).

Figure 86 Fixing strain relief screws

5 Lift the RRH onto the pole using the lifting point.

g Note: Do not lift the RRH onto a pole by the handle. Use the lifting point instead.

g Note: Take care when lifting the Remote Radio Head as it is very heavy.

g Note: Use a rope which is strong enough to support the module.

78 DN09185846 Issue: 06A
   

Installing and Cabling Flexi Multiradio Remote Radio Installing and cabling Flexi RRH 2TX 730 (FRLB) onto
Heads a pole

Figure 87 Lifting FRLB

Liftingpoint

Issue: 06A DN09185846 79
   

Installing and cabling Flexi RRH 2TX 730 (FRLB) onto Installing and Cabling Flexi Multiradio Remote Radio
a pole Heads

6 Fix the FPKA lower bracket to 30 Nm (22.13 ft-lb.).

Figure 88 Fixing FPKA lower bracket

7 Tighten all FPKA fixing bolts.


Make sure that the bolts are tightened to 20 Nm (14.75 ft-lb.).

8 Connect the grounding cable.

Figure 89 Connecting grounding cable

80 DN09185846 Issue: 06A
   

Installing and Cabling Flexi Multiradio Remote Radio Installing and cabling Flexi RRH 2TX 730 (FRLB) onto
Heads a pole

9 If applicable, connect the EAC cable.

Figure 90 Connecting EAC cable

10 If applicable, connect the LMP cable.

Figure 91 Connecting LMP cable

11 Connect the optical cables and fix them using cable clamps.
Straight optical cables are recommended. Do not exceed minimum bending radius of
70 mm (2.76 inches) for cables with a diameter 7 mm (0.28 inches) or 50 mm (1.97
inches) for cables with a diameter 5 mm (0.20 inches).

Issue: 06A DN09185846 81
   

Installing and cabling Flexi RRH 2TX 730 (FRLB) onto Installing and Cabling Flexi Multiradio Remote Radio
a pole Heads

Figure 92 Connecting optical cables

12 Connect the antenna cables and tighten them to 25 Nm (18.4 ft-lb).

w NOTICE:  When using a large torque wrench to tighten the cable connections, be
careful not to damage any of the other smaller connectors.

Figure 93 Connecting antenna cables

13 Connect the DC power cable as follows:

a) Strip about 10 cm (4 in) of the DC cable and wrap some tape around the
exposed wires to prevent to IP from breaking.

82 DN09185846 Issue: 06A
   

Installing and Cabling Flexi Multiradio Remote Radio Installing and cabling Flexi RRH 2TX 730 (FRLB) onto
Heads a pole

Figure 94 Wrapping tape around DC cable

b) Insert the taped end of the DC feeder cable into the IP boot and feed it through.
Figure 95 Inserting DC feeder cable into an IP boot

When using a thick cable, the narrow end of the IP boot can be removed using
scissors. Use a single cut to ensure a clean cut surface. For details, see Figure
Removing narrow end of IP boot. The cable diameter cannot be wider than 25
mm (1 in.) or be narrower than 6 mm (0.24 in.).
Note that you can insert only one DC cable with a diameter of max. 25 mm (1 in.)
to the IP boot.

w NOTICE: The IP boot edge must be smooth. Ensure there are no cracks present in the
edge, as it compromises boot IP protection.

Issue: 06A DN09185846 83
   

Installing and cabling Flexi RRH 2TX 730 (FRLB) onto Installing and Cabling Flexi Multiradio Remote Radio
a pole Heads

Figure 96 Removing narrow end of an IP boot

Cablediameter20.1-25mm,
useasinglecut
Cablediameter11.1-20mm,
useasinglecut

Cablediameter6-11mm

c) Remove the tape.
d) Connect the wires to the screw terminal and tighten to 3.0 Nm (3.69 ft-lb.).
e) Secure the IP boot, apply the screws and tighten (them) to max 7.0 Nm (17.7 in-
lb.).

g Note: On sites where birds or rodents are a concern, it is recommended that exposed
cables and DC terminal seals be protected with conduit. Use any suitable standard
conduit for that purpose. Make sure that the conduit is securely locked in position as
close to the IP seals as possible.

Figure 97 Example of conduit usage

f) Attach the DC cable clamp to the strain relief.

84 DN09185846 Issue: 06A
   

Installing and Cabling Flexi Multiradio Remote Radio Installing and cabling Flexi RRH 2TX 730 (FRLB) onto
Heads a pole

Figure 98 Attaching DC cable clamp

g) Secure the cable in place with a cable clamp.
Figure 99 Securing a DC cable in place

14 If applicable, connect the RET cable.


Push the cable all the way down into the connector on the RRH front panel and then
twist it. Tighten to max 0.5 - 1.0 Nm (4.43 - 8.85 in-lb.). Only hand-tightening is
allowed.
If no RET cable is connected, place the shipping cap back onto the RET connector.

Issue: 06A DN09185846 85
   

Installing and cabling Flexi RRH 2TX 730 (FRLB) onto Installing and Cabling Flexi Multiradio Remote Radio
a pole Heads

Figure 100 Connecting RET cable

15 If applicable, connect the RX out cables.

Figure 101 Connecting two RX out cable

16 Secure all cables with cable ties.

Figure 102 Securing cables with cable ties

86 DN09185846 Issue: 06A
   

Installing and Cabling Flexi Multiradio Remote Radio Installing and cabling Flexi RRH 4TX 2100 (FRIG and
Heads FHGB) onto a pole

10 Installing and cabling Flexi RRH 4TX 2100


(FRIG and FHGB) onto a pole
These instructions show the installation and cabling procedure for the Flexi RRH 4TX
2100 (FRIG and FHGB) Remote Radio Heads onto a pole.

Purpose
Use Flexi Pole Mounting Kit (FPKA) for installing Flexi Remote Radio Head 4TX 1.7/2.1
GHz (FRIG) onto a pole. If your FPKA includes both plinth (FMFA) and RRH
installations, see Installing Flexi RRH 2TX on the pole opposite to FMFA for instructions.
Two FRIG modules can be installed onto one FPKA.
The FRIG and FHGB interfaces are shown in the following diagrams.

Figure 103 FRIG interfaces
ANT4 ANT3 ANT2 ANT1 RET

EAC LMP LEDs OPT2 DCIN


OPT 3 OPT1 Ground

Issue: 06A DN09185846 87
   

Installing and cabling Flexi RRH 4TX 2100 (FRIG and Installing and Cabling Flexi Multiradio Remote Radio
FHGB) onto a pole Heads

Figure 104 FHGB interfaces
TXM4 TXM3 CUSTI/O TXM2 TXM1
RXM4 RXM3 RXM2 RXM1
ANT4 ANT3 ANT2 ANT1 RET

EAC LMP OPT3 OPT2 OPT1

Procedure

1 Install the upper FPKA bracket onto the pole as instructed in Installing Flexi
Pole Mounting Kit (FPKA).

2 Release the strain relief by undoing the screw.


Reserve the screw for later use.

88 DN09185846 Issue: 06A
   

Installing and Cabling Flexi Multiradio Remote Radio Installing and cabling Flexi RRH 4TX 2100 (FRIG and
Heads FHGB) onto a pole

Figure 105 Releasing strain relief

3 Fix the lower FPKA bracket onto the back of the FRIG.

Figure 106 Fixing FPKA onto FRIG

Issue: 06A DN09185846 89
   

Installing and cabling Flexi RRH 4TX 2100 (FRIG and Installing and Cabling Flexi Multiradio Remote Radio
FHGB) onto a pole Heads

4 Fix the strain relief onto the lower bracket using two M5 screws and tighten
them to 4 Nm (2.95 ft-lb.).

Figure 107 Fixing strain relief screws

5 Lift the RRH on the pole using the lifting point.

w NOTICE:  Do not lift the RRH on the pole by the handle. Use the lifting point instead.

f CAUTION! Risk of personal injury.


Take care when lifting the Remote Radio Head as it is very heavy.

g Note: Use a rope which is strong enough to support the module.

90 DN09185846 Issue: 06A
   

Installing and Cabling Flexi Multiradio Remote Radio Installing and cabling Flexi RRH 4TX 2100 (FRIG and
Heads FHGB) onto a pole

Figure 108

Liftingpoint

Issue: 06A DN09185846 91
   

Installing and cabling Flexi RRH 4TX 2100 (FRIG and Installing and Cabling Flexi Multiradio Remote Radio
FHGB) onto a pole Heads

6 Attach the FPKA lower bracket to 30 Nm (22.13 ft-lb.).

Figure 109 Attaching FPKA lower bracket

7 Tighten all FPKA fixing bolts.


Ensure that the bolts are tightened to 20 Nm (14.75 ft-lb.).

8 Connect the grounding cable.

Figure 110 Connecting a grounding cable

92 DN09185846 Issue: 06A
   

Installing and Cabling Flexi Multiradio Remote Radio Installing and cabling Flexi RRH 4TX 2100 (FRIG and
Heads FHGB) onto a pole

9 If applicable, connect the EAC cable.

Figure 111 Connecting EAC cable

10 If applicable, connect the LMP cable.

Figure 112 Connecting LMP cable

11 Connect the optical cables and fix them using cable clamps.
Insert SFP modules to ports that are to be used.

g Note: Straight optical cables are recommended. Do not exceed minimum bending
radius of 70 mm (2.76 inches) for cables with a diameter 7 mm (0.28 inches) or 50 mm
(1.97 inches) for cables with a diameter 5 mm (0.20 inches).

12 Connect the antenna cables and tighten them to 25 Nm (18.4 ft-lb).

w NOTICE:  When using a large torque wrench to tighten the cable connections, be
careful not to damage any of the other smaller connectors.

Issue: 06A DN09185846 93
   

Installing and cabling Flexi RRH 4TX 2100 (FRIG and Installing and Cabling Flexi Multiradio Remote Radio
FHGB) onto a pole Heads

Figure 113 Connecting antenna cables

13 Connect the DC power cable as follows:

a) Strip about 10 cm (4 in) of the DC cable and wrap some tape around the
exposed wires to prevent to IP from breaking.
Figure 114 Wrapping tape around DC cable

b) Insert the taped end of the DC feeder cable into the IP boot.

94 DN09185846 Issue: 06A
   

Installing and Cabling Flexi Multiradio Remote Radio Installing and cabling Flexi RRH 4TX 2100 (FRIG and
Heads FHGB) onto a pole

Figure 115 Inserting DC power cable into an IP boot

When using a thick cable, the narrow end of the IP boot can be removed using
scissors. Use a single cut to ensure a clean cut surface. For details, see Figure
116: Removing narrow end of an IP boot. The cable diameter cannot be wider
than 25 mm (1 in.) or be narrower than 6 mm (0.24 in.).
Note that you can insert only one DC cable with a diameter of max. 25 mm (1 in.)
to the IP boot.

w NOTICE: The IP boot edge must be smooth. Ensure there are no cracks present in the
edge, as it compromises boot IP protection.

Figure 116 Removing narrow end of an IP boot

Cablediameter20.1-25mm,
useasinglecut
Cablediameter11.1-20mm,
useasinglecut

Cablediameter6-11mm

c) Remove the tape.
d) Connect the wires to the screw terminal and tighten to 3.0 Nm (3.7 ft-lb.).
e) Secure the IP boot, apply the screws and tighten them to max. 7.0 Nm (1.5 in-
lb.).

Issue: 06A DN09185846 95
   

Installing and cabling Flexi RRH 4TX 2100 (FRIG and Installing and Cabling Flexi Multiradio Remote Radio
FHGB) onto a pole Heads

g Note: On sites where birds or rodents are a concern, it is recommended that exposed
cables and DC terminal seals be protected with conduit. Use any suitable standard
conduit for that purpose. Make sure that the conduit is securely locked in position as
close to the IP seals as possible.

Figure 117 Example of conduit usage

f) Attach the DC cable clamp to the strain relief.
Figure 118 Attach DC cable clamp

g) Secure the cable in place with the cable clamp.

96 DN09185846 Issue: 06A
   

Installing and Cabling Flexi Multiradio Remote Radio Installing and cabling Flexi RRH 4TX 2100 (FRIG and
Heads FHGB) onto a pole

Figure 119 Securing DC cable in place

14 If applicable, connect the RET cable.


Push the cable all the way down into the connector on the RRH front panel and then
twist it. Tighten to max 0.5 - 1.0 Nm (4.4 - 8.9 in-lb.). Only hand-tightening is allowed.
If no RET cable is connected, place the shipping cap back onto the RET connector.

15 If applicable, connect the RX out cables.

Figure 120 Connecting RX out cable

Issue: 06A DN09185846 97
   

Installing and cabling Flexi RRH 4TX 2100 (FRIG and Installing and Cabling Flexi Multiradio Remote Radio
FHGB) onto a pole Heads

16 Secure all cables with cable ties.

Figure 121 Securing cables with cable ties

98 DN09185846 Issue: 06A
   

Installing and Cabling Flexi Multiradio Remote Radio Installing and cabling Flexi RRH 2TX 850 (FHCA) onto
Heads a pole

11 Installing and cabling Flexi RRH 2TX 850


(FHCA) onto a pole
These instructions show the installation and cabling procedure for the Flexi RRH 2TX
850 (FHCA) Remote Radio Heads onto a pole.

Purpose
Use Flexi Pole Mounting Kit (FPKA) for installing Flexi Remote Radio Head 2TX onto a
pole. If your FPKA includes both plinth (FMFA) and RRH 2TX installations, see Installing
Flexi RRH 2TX 850 on the pole opposite to FMFA for instructions.
The Flexi RRH 2TX 850 (FHCA) interfaces are shown in the below diagram.

Figure 122 FHCA interfaces
DC IN OPT1 OPT2 RET

PWR MAIN

+V48RTN -V48N
LMP EAC

ANT1 ANT2

Procedure

1 Install Flexi Pole Mounting Kit (FPKA) as instructed in Installing Flexi Pole
Mounting Kit (FPKA).

2 Release the strain relief by undoing the screw.


Reserve the screw for later use.

Issue: 06A DN09185846 99
   

Installing and cabling Flexi RRH 2TX 850 (FHCA) onto Installing and Cabling Flexi Multiradio Remote Radio
a pole Heads

Figure 123 Releasing strain relief

3 Fix the strain relief plate onto the lower bracket using two M5 screws and
tighten them to 4 Nm (2.95 ft-lb.).

Figure 124 Releasing strain relief

100 DN09185846 Issue: 06A


   

Installing and Cabling Flexi Multiradio Remote Radio Installing and cabling Flexi RRH 2TX 850 (FHCA) onto
Heads a pole

4 Tighten the fixing bolts to 20 Nm (14.8 ft-lb.).

5 Lift the RRH on the pole using the lifting point..

g Note: Do not lift the RRH on the pole by the handle. Use the lifting point instead.

g Note: Take care when lifting the Remote Radio Head as it is very heavy.

g Note: Use a rope which is strong enough to support the module.

Figure 125 Fixing FHCA to the FPKA bracket

Issue: 06A DN09185846 101


   

Installing and cabling Flexi RRH 2TX 850 (FHCA) onto Installing and Cabling Flexi Multiradio Remote Radio
a pole Heads

6 Attach the DC cable clamp on the strain relief.

Figure 126 Attaching DC cable clamp

7 Connect the grounding cable:

a) Remove the two M5x10 screws from the grounding lug screw holes on the RRH.
b) Place the grounding lug above the holes and connect the grounding cable (not
included in the package) to the lug.
c) Re-insert and tighten the two M5x10 screws to the grounding lug screw holes on
the RRH with a torque of 4.5 Nm (39.8 in-lb.).

8 Connect the antenna cables:

a) Remove the caps from the DIN 7/16 connectors on the bottom of the RRH.
b) Connect the feeder/jumper cables from the antenna/co-location filter with the DIN
7/16 connectors.
c) Tighten the connectors to 25 Nm (18.4 ft-lb.) using an adjustable wrench and
alligator pliers.

w NOTICE:  When using a large torque wrench to tighten the cable connections, be
careful not to damage any of the other smaller connectors.

102 DN09185846 Issue: 06A


   

Installing and Cabling Flexi Multiradio Remote Radio Installing and cabling Flexi RRH 2TX 850 (FHCA) onto
Heads a pole

Figure 127 Connecting antenna cables

9 Connect the optical cables:


Straight optical cables are recommended. Do not bend optical fiber cables to a
radius smaller than the minimum radius of 70 mm (2.76 inches) for cables with a
diameter 7 mm (0.28 inches) or 50 mm (1.97 inches) for cables with a diameter 5
mm (0.20 inches).
a) Remove the cap from the OPT1 connector (Slave to BTS).
b) Insert the optical SFP module gently into the cage and connect with the optical
cable and IP seal.
c) When daisy chaining the RRH to another RRH, remove the cap from the OPT2
connector (Master to another RRH).
Insert the optical SFP module gently into the cage and connect with the optical
cable and IP seal.
d) Fix the optical cables to the strain relief using cable clamps.

Issue: 06A DN09185846 103


   

Installing and cabling Flexi RRH 2TX 850 (FHCA) onto Installing and Cabling Flexi Multiradio Remote Radio
a pole Heads

Figure 128 Connecting optical cables

10 Connect the DC power cable as follows:

a) Strip about 10 cm (4 in) of the DC cable and wrap some tape around the
exposed wires to prevent to IP from breaking.
Figure 129 Wrapping tape around DC cable

b) Insert the taped end of the DC feeder cable into the IP boot.

104 DN09185846 Issue: 06A


   

Installing and Cabling Flexi Multiradio Remote Radio Installing and cabling Flexi RRH 2TX 850 (FHCA) onto
Heads a pole

Figure 130 Inserting DC power cable into an IP boot

When using a thick cable, the narrow end of the IP boot can be removed using
scissors. Use a single cut to ensure a clean cut surface. For details, see Figure
131: Removing narrow end of an IP boot. The cable diameter cannot be wider
than 25 mm (1 in.) or be narrower than 6 mm (0.24 in.).
Note that you can insert only one DC cable with a diameter of max. 25 mm (1 in.)
to the IP boot.

w NOTICE: The IP boot edge must be smooth. Ensure there are no cracks present in the
edge, as it compromises boot IP protection.

Figure 131 Removing narrow end of an IP boot

Cablediameter20.1-25mm,
useasinglecut
Cablediameter11.1-20mm,
useasinglecut

Cablediameter6-11mm

c) Remove the tape.
d) Connect the wires to the screw terminal and tighten to 5 Nm (3.7 ft-lb.).
e) Secure the IP boot, apply the screws and tighten them to max. 2.0 Nm (17.7 in-
lb.).

Issue: 06A DN09185846 105


   

Installing and cabling Flexi RRH 2TX 850 (FHCA) onto Installing and Cabling Flexi Multiradio Remote Radio
a pole Heads

f) Fix the DC cable clamp on the strain relief.
Figure 132 Fixing DC power cable

11 If applicable, connect the EAC cable.

12 If applicable, connect the RET cable.


Push the cable all the way down into the connector on the RRH front panel and then
twist it. Tighten to max 0.5 - 1.0 Nm (4.4 - 8.9 in-lb.). Only hand-tightening is allowed.
If no RET cable is connected, place the shipping cap back onto the RET connector.

13 Secure all cables with cable ties.

106 DN09185846 Issue: 06A


   

Installing and Cabling Flexi Multiradio Remote Radio Installing and cabling Flexi TRS External Filter for
Heads FHCA (FFCB) onto a pole

12 Installing and cabling Flexi TRS External


Filter for FHCA (FFCB) onto a pole
These instructions show the installation and cabling procedure for the Flexi TRS External
Filter for FHCA (FFCB) Remote Radio Heads onto a pole.

Purpose
These instructions show the installation procedure for the Flexi TRS External Filter for
FHCA (FFCB) on a pole. Mounting brackets are pre-installed.

Procedure

1 While on the ground, thread the hose clamps through the two slots on each
mounting bracket.

Figure 133 Threading hose clamps on a mounting bracket

Issue: 06A DN09185846 107


   

Installing and cabling Flexi TRS External Filter for Installing and Cabling Flexi Multiradio Remote Radio
FHCA (FFCB) onto a pole Heads

Figure 134 Hose clamps in place

108 DN09185846 Issue: 06A


   

Installing and Cabling Flexi Multiradio Remote Radio Installing and cabling Flexi TRS External Filter for
Heads FHCA (FFCB) onto a pole

2 Position the FFCB on the pole with ANT1 and ANT2 connectors at the top.

3 Wrap the hose clamps around the pole and thread them through the worm
screw assembly.

Figure 135 Mounting FFCB on a pole

Issue: 06A DN09185846 109


   

Installing and cabling Flexi TRS External Filter for Installing and Cabling Flexi Multiradio Remote Radio
FHCA (FFCB) onto a pole Heads

4 Tighten the worm screw assemblies.

Figure 136 Tightening worm screw assembly

110 DN09185846 Issue: 06A


   

Installing and Cabling Flexi Multiradio Remote Radio Installing and cabling Flexi TRS External Filter for
Heads FHCA (FFCB) onto a pole

Figure 137 FFCB on a pole

Issue: 06A DN09185846 111


   

Installing and cabling Flexi TRS External Filter for Installing and Cabling Flexi Multiradio Remote Radio
FHCA (FFCB) onto a pole Heads

5 Connect the grounding cable (grounding point is located between the BTS1
and BTS2 ports).

Figure 138 Connecting FFCB grounding cable (M5)

6 Connect a 7/16 antenna jumper cable (approximately 1.5 meters long, included
in the delivery) from the FHCA RF output (ANT1 connector) to the port labelled
BTS1 on the FFCB.
Only use the antenna jumper cables provided with the delivery. Tighten to 25 Nm
(14.8 ft-lb.).

112 DN09185846 Issue: 06A


   

Installing and Cabling Flexi Multiradio Remote Radio Installing and cabling Flexi TRS External Filter for
Heads FHCA (FFCB) onto a pole

Figure 139 Connecting jumper cable to BTS1

Issue: 06A DN09185846 113


   

Installing and cabling Flexi TRS External Filter for Installing and Cabling Flexi Multiradio Remote Radio
FHCA (FFCB) onto a pole Heads

7 Connect a jumper cable from the port labelled ANT1 on the FFCB to the
antenna feeder cable.

Figure 140 Connecting jumper cable to ANT1

8 Repeat steps 6 and 7 for BTS2 and ANT2 ports.

9 Check that the connectors are correctly mated and securely fastened.
Make sure that the bend radius of the cables do not place stress on the cable or
connectors.

10 Make sure that any excess cabling is securely fixed to the pole to prevent it
from moving.

114 DN09185846 Issue: 06A


   

Installing and Cabling Flexi Multiradio Remote Radio Installing and cabling Flexi TRS External Filter for
Heads FHCA (FFCB) onto a wall

13 Installing and cabling Flexi TRS External


Filter for FHCA (FFCB) onto a wall
These instructions show the installation and cabling procedure for the Flexi TRS External
Filter for FHCA (FFCB) Remote Radio Heads onto a wall.

Purpose
These instructions show the installation procedure for Flexi TRS External Filter for FHCA
(FFCB) on a wall. Mounting brackets are pre-installed.

Procedure

1 Using the FFCB as a template, mark the screw hole locations on the wall.

Figure 141 Marking FFCB screw hole locations

Issue: 06A DN09185846 115


   

Installing and cabling Flexi TRS External Filter for Installing and Cabling Flexi Multiradio Remote Radio
FHCA (FFCB) onto a wall Heads

2 Drill the holes.

3 Position the FFCB on the wall with ANT1 and ANT2 connectors at the top.

4 Fix with four M8 screws or bolts.

Figure 142 Fixing FFCB on a wall

5 Proceed with cabling as instructed in Installing Flexi TRS External Filter for
FHCA (FFCB) on a pole.

116 DN09185846 Issue: 06A


   

Installing and Cabling Flexi Multiradio Remote Radio Installing and cabling Flexi RRH 2-pipe 700/840
Heads (FHPC) onto a pole

14 Installing and cabling Flexi RRH 2-pipe


700/840 (FHPC) onto a pole
These instructions show the installation and cabling procedure for the Flexi RRH 2-pipe
700/840 (FHPC) Remote Radio Heads onto a pole.

Purpose
Use Flexi Pole Mounting Kit (FPKA) when installing Flexi Remote Radio Head 2-pipe
700/840 100W (FHPC) onto a pole.

g Note: Make sure that the minimum distance between the gap of N connector and cable
ladder is 120 mm.

The FHPC interfaces are shown in the following diagram.

Figure 143 FHPC interfaces
AISG ANT0 TXMON0 TXMON1 ANT1 CUSTI/O

LTEBBU LTERRH FG -48VDC

Issue: 06A DN09185846 117


   

Installing and cabling Flexi RRH 2-pipe 700/840 Installing and Cabling Flexi Multiradio Remote Radio
(FHPC) onto a pole Heads

Procedure

1 Install the upper FPKA bracket onto the pole as instructed in Installing Flexi
Pole Mounting Kit (FPKA).

2 Install the static mounting bracket onto the FPKA bracket with four M8 bolts.

Figure 144 Installing a static mounting bracket to the FPKA

3 Install the FHPC to the mounting bracket with eight M5 bolts.


Shift the adapter up to obtain the result as shown in the Figure 146: FHPC mounted
onto a pole with a mounting bracket.

f Take care when lifting the Remote Radio Head as it is very heavy.

118 DN09185846 Issue: 06A


   

Installing and Cabling Flexi Multiradio Remote Radio Installing and cabling Flexi RRH 2-pipe 700/840
Heads (FHPC) onto a pole

Figure 145 Installing FHPC onto a vertical pole

Step result
FHPC is mounted onto a mounting bracket.
Figure 146 FHPC mounted onto a pole with a mounting bracket

Issue: 06A DN09185846 119


   

Installing and cabling Flexi RRH 2-pipe 700/840 Installing and Cabling Flexi Multiradio Remote Radio
(FHPC) onto a pole Heads

4 Tighten all fixing bolts.

5 Connect the grounding cable.

g Note: Make sure that the minimum distance between the gap of N connector and cable
ladder is 120 mm.

Figure 147 Connecting a grounding cable

6 Connect the antenna cables and tighten them to 0.9 Nm (0.7 ft-lb).

w NOTICE:  When using a large torque wrench to tighten the cable connections, be
careful not to damage any of the other smaller connectors.

Figure 148 Connecting antenna cables

120 DN09185846 Issue: 06A


   

Installing and Cabling Flexi Multiradio Remote Radio Installing and cabling Flexi RRH 2-pipe 700/840
Heads (FHPC) onto a pole

7 Connect the DC power cable.

Figure 149 Connecting DC power cable

8 Secure all cables with cable ties.

Issue: 06A DN09185846 121


   

Installing and cabling s-RRH850 (FHCB) Installing and Cabling Flexi Multiradio Remote Radio
Heads

15 Installing and cabling s-RRH850 (FHCB)


These instructions provide the installation information for s-RRH850 (FHCB) Remote
Radio Heads.

Procedure

1 Slide the FHCB module into the rack and fix it with four screws.

2 Connect power cables.


Depending on power supply type, connect power cables, as shown in the Figure 150:
Connecting power supply.

Figure 150 Connecting power supply
-48VConnection +27VConnection

-48V GND +27V -48V GND +27V


DCSwitch DCSwitch
DCIN DCIN

3 Connect the optical cable.


Connect the optical between System Module and the FHCB Optic1 interface.

4 Connect the RF cables.


Connect the RF cables between the Optic Repeater MU and the FHCB Rx and Tx
interfaces.
Use the following logic: Tx0 -> Tx0, Tx1 -> Tx1, Rx0 -> Rx0, Rx1 -> Rx1.

5 If applicable, connect the LMP cable.

6 Switch on the power.

122 DN09185846 Issue: 06A


   

Installing and Cabling Flexi Multiradio Remote Radio Installing and cabling s-RRH1800 (FHEC)
Heads

16 Installing and cabling s-RRH1800 (FHEC)


These instructions provide the installation information for s-RRH1800 (FHEC) Remote
Radio Heads.

Procedure

1 Slide the FHEC module onto the rack and fix it with four screws.

2 Connect power cables.


Depending on power supply type, connect power cables, as shown in the Figure 151:
Connecting power supply.

Figure 151 Connecting power supply

-48V GND

DCSwitch DCIN

-48VConnection

3 Connect the optical cable.


Connect the optical between the System Module and the FHEC Optic1 interface.

4 Connect the RF cables.


Connect the RF cables between Optic Repeater MU and the FHEC Rx and Tx
interfaces.
Use the following logic: Tx0 -> Tx0, Tx1 -> Tx1, Rx0 -> Rx0, Rx1 -> Rx1.
If any external equipment (for example a repeater) needs 10MHz reference, connect
10M1 ~ 10M4 interfaces.

5 If applicable, connect the LMP cable.

6 Switch on the power.

Issue: 06A DN09185846 123


   

Installing Flexi RRH 2TX onto a pole opposite to FMFA Installing and Cabling Flexi Multiradio Remote Radio
Heads

17 Installing Flexi RRH 2TX onto a pole opposite


to FMFA
Step by step instruction for installing Flexi RRH 2TX onto a pole opposite to FMFA.

Purpose
Use Flexi Pole Mounting Kit (FPKA) when installing Flexi Remote Radio Head 2TX onto
a pole. Follow these instructions if your FPKA includes both plinth (FMFA) and RRH 2TX
installations. Mount the RRH opposite the plinth (adjacent installation is not supported).
Only one RRH is supported in this configuration.

w NOTICE: FMFA requires 482.5 mm (19 in.) vertical spacing.

Procedure

1 Install Flexi Pole Mounting Kit (FPKA) as instructed in Installing Flexi Pole
Mounting Kit (FPKA).

2 Move the RRH mounting kit brackets so that the fixing bolts are fixed to the
outermost holes. Tighten the bolts to 20 Nm (14.75 ft-lb).

Figure 152 Moving RRH mounting kit brackets

1 2

124 DN09185846 Issue: 06A


   

Installing and Cabling Flexi Multiradio Remote Radio Installing Flexi RRH 2TX onto a pole opposite to FMFA
Heads

3 Release the strain relief by undoing the screw. Reserve the screw for later use.

g Note: This step does not apply to FHDB and FHEB modules.

Figure 153 Releasing strain relief

4 Apply the two screws on the strain relief.

g Note: This step does not apply to FHDB and FHEB modules.

Issue: 06A DN09185846 125


   

Installing Flexi RRH 2TX onto a pole opposite to FMFA Installing and Cabling Flexi Multiradio Remote Radio
Heads

Figure 154 Attaching strain relief screws

g Note: Handle the released strain relief with care when lifting the RRH to its target
location.

5 Follow the instructions provided in Installing Flexi RRH 2TX on the pole (steps
2-15) for information on how to cable and lift the RRH onto a pole.

126 DN09185846 Issue: 06A


   

Installing and Cabling Flexi Multiradio Remote Radio Installing Flexi 2x40 W RRH onto a wall
Heads

18 Installing Flexi 2x40 W RRH onto a wall


These instructions show the installation and cabling procedure for the Flexi 2x40 W
Remote Radio Head onto a wall.

Procedure

1 Mark the mounting hole locations on the wall and drill holes for the screws.
For the two different options, see Moving RRH mounting kit brackets.

Figure 155 Drilling mounting holes (RRH mounting kit fixing bolts fixed to the
innermost holes)

185mm

532 mm

Issue: 06A DN09185846 127


   

Installing Flexi 2x40 W RRH onto a wall Installing and Cabling Flexi Multiradio Remote Radio
Heads

Figure 156 Drilling mounting holes (RRH mounting kit fixing bolts fixed to the
outermost holes)

185mm

482.5mm

2 Lift the RRH onto the wall.


Do not lift the RRH from the plastic cover. Place your hand on the bottom of the RRH
and then lift.

f Take care when lifting the Remote Radio Head as it is very heavy.

Figure 157 Lifting RRH onto a wall

A B C

128 DN09185846 Issue: 06A


   

Installing and Cabling Flexi Multiradio Remote Radio Installing Flexi 2x40 W RRH onto a wall
Heads

3 Tighten the upper fixing bolts to 20 Nm (14.75 ft-lb).

4 Release the strain relief by undoing the screw.


Reserve the screw for later use.

Figure 158 Releasing strain relief

5 Fix the two screws on the strain relief.

Figure 159 Fixing strain relief screws

Issue: 06A DN09185846 129


   

Installing Flexi 2x40 W RRH onto a wall Installing and Cabling Flexi Multiradio Remote Radio
Heads

6 Tighten the lower fixing bolts to 20 Nm (14.75 ft-lb).

7 Attach the DC cable clamp on the strain relief.

Figure 160 Attaching DC cable clamp

8 Connect the cabling as instructed in Installing Flexi RRH 2TX on the pole.

130 DN09185846 Issue: 06A


   

Installing and Cabling Flexi Multiradio Remote Radio Installing Flexi 2x60 W RRH onto a wall
Heads

19 Installing Flexi 2x60 W RRH onto a wall


These instructions show the installation and cabling procedure for the Flexi 2x60 W
Remote Radio Head onto a wall.

Procedure

1 Install the lower fixing bracket.

a) Place the RRH upside down.
Figure 161 Placing the RRH upside down (2x60 W RRH)

b) Align the “FMFA” or “ALT” M5 screw holes on the fixing bracket with the M5 holes
on the RRH.

Issue: 06A DN09185846 131


   

Installing Flexi 2x60 W RRH onto a wall Installing and Cabling Flexi Multiradio Remote Radio
Heads

Figure 162 Aligning lower fixing bracket

g Note: “ALT” should only be used when installing the 2x60W RRH onto a FPKA/VMPB
or wall rails with already installed 2x40W RRH (installed with 532 mm vertical spacing).

c) Tighten six M5 screws to 5 Nm (3.7 ft-lb).

2 Attach the DC cable clamp to the strain relief.

Figure 163 Attaching DC cable clamp (2x60 W RRH)

132 DN09185846 Issue: 06A


   

Installing and Cabling Flexi Multiradio Remote Radio Installing Flexi 2x60 W RRH onto a wall
Heads

3 Mark the mounting hole locations on the wall and drill holes for the screws.

Figure 164 Drilling mounting holes

185mm

Verticalspacing
dependsonsite
requirements

g Note: For vertical spacing options, see
Dimension guidelines for wall and pole mounting.

4 Lift the RRH onto the wall and mount it by performing the following steps:

a) Fix two upper mounting screws.
b) Hang the bracket on the screws.
c) Insert the lower screws.
d) Tighten four screws to 20 Nm (14.8 ft-lb).

w NOTICE: Take care when lifting the Remote Radio Head as it is very heavy.

w NOTICE: Use a rope which is strong enough to support the module.

Issue: 06A DN09185846 133


   

Installing Flexi 2x60 W RRH onto a wall Installing and Cabling Flexi Multiradio Remote Radio
Heads

Figure 165 Lifting RRH onto a wall

A B C

5 Tighten the four M8 screws to 20 Nm (14.8 ft-lb).

6 Connect the cabling as instructed in Installing Flexi 2x60W RRH on a pole.

134 DN09185846 Issue: 06A


   

Installing and Cabling Flexi Multiradio Remote Radio Installing RRH Release 4 onto a wall
Heads

20 Installing RRH Release 4 onto a wall


These instructions show the installation procedure for the Release 4 Remote Radio
Heads onto a wall.

Procedure

1 Install the lower fixing bracket as instructed in Step 1 of Installing and cabling
RRH Release 4 onto a pole.

2 Mark the mounting hole locations on the wall and drill holes for the screws.

w For available spacing options, see chapter
Installing and cabling RRH Release 4 onto a pole.

w NOTICE: The bottom holes can be drilled after hanging the module off the top screws.

Figure 166 Drilling mounting holes

185mm

Verticalspacing
dependsonsite
requirements

3 Lift the RRH onto the wall. Use the lifting point.

f Take care when lifting the Remote Radio Head as it is very heavy.

w NOTICE: Do not remove the lifting rope until the RRH is secured on the bolts.

Issue: 06A DN09185846 135


   

Installing RRH Release 4 onto a wall Installing and Cabling Flexi Multiradio Remote Radio
Heads

Figure 167 Lifting RRH onto a wall

Liftingpoint

4 Tighten the four M8 screws to 20 Nm (14.8 ft-lb).

5 Connect the cabling as instructed in Installing and cabling RRH Release 4 onto
a pole.

136 DN09185846 Issue: 06A


   

Installing and Cabling Flexi Multiradio Remote Radio Installing Flexi RRH 2-pipe 700/840 (FHPC) onto a wall
Heads

21 Installing Flexi RRH 2-pipe 700/840 (FHPC)


onto a wall
These instructions show the installation and cabling procedure for the Flexi RRH 2-pipe
700/840 (FHPC) Remote Radio Heads onto a wall.

Purpose
The RRH must be properly mounted to the wall and therefore it is necessary to use the
appropriate fixing construction or dowels for the type of wall. Use M8 screws for
mounting the RRH onto the wall.

g Note: Make sure that the minimum distance between the gap of N connector and cable
ladder is 120 mm.

Procedure

1 Mark the mounting hole locations on the wall and drill holes for the screws.

Figure 168 Drilling holes in a wall for FHPC

250 mm
280mm

2 Install the static mounting bracket on the wall with four M8 bolts by performing
the following steps:

a) Apply two upper mounting screws.
b) Hang the static mounting bracket on the screws.
c) Insert the lower screws.
d) Tighten the four M8 bolts to 13.75 Nm (10 ft-lb).

Issue: 06A DN09185846 137


   

Installing Flexi RRH 2-pipe 700/840 (FHPC) onto a wall Installing and Cabling Flexi Multiradio Remote Radio
Heads

Figure 169 Mounting a static mounting bracket on a wall

A B C

3 Lift the FHPC module and mount it onto the static mounting bracket with eight
M5 bolts.
Shift the adapter up to obtain the result as shown in the Figure 171: FHPC mounted
onto a wall with a mounting bracket.

f Take care when lifting the Remote Radio Head as it is very heavy.

Figure 170 Mounting FHPC module onto a static mounting bracket

Step result
FHPC is mounted onto a mounting bracket.

138 DN09185846 Issue: 06A


   

Installing and Cabling Flexi Multiradio Remote Radio Installing Flexi RRH 2-pipe 700/840 (FHPC) onto a wall
Heads

Figure 171 FHPC mounted onto a wall with a mounting bracket

4 Tighten all fixing bolts.


Ensure that the bolts are tightened to 2.2 Nm (1.62 ft-lb).

5 Connect the cabling as instructed in Installing and cabling Flexi RRH 2-pipe
700/840 (FHPC) onto a pole.

Issue: 06A DN09185846 139


   

Installing first RRH with FPKC Installing and Cabling Flexi Multiradio Remote Radio
Heads

22 Installing first RRH with FPKC


These instructions show the installation procedure for the Remote Radio Heads using
FPKC Mounting Kit.

Purpose
Flexi Pole Mounting Kit is required for mounting modules on poles. FPKC is designed for
poles between 60 mm (2.36 in) and 300 mm (11.81 in) in diameter.
Two FPKC kits are required for the minimum installation, which allows to install two
RRHs on opposite sides of FPKC.
There is no need to use thread-locking compound or lock nuts when installing the FPKC.

Before you start


M10x315mm pole mount screw can be cut down to correct installation specific lengths
for pole installations in the field. There are four different lengths of the screw available
and four places for the screw in the FPKC. When attaching the FPKC to poles, use the
shortest possible bolts and the holes whose distance is the closest to the pole diameter.
For more details, see Screw cut locations, Screw installation slots, and Pole diameter
table related to cut location and installation slot for optimum pole mounting.

Figure 172 Screw cut locations

L-BarCut Cut1 Cut2 NoCut

Figure 173 Screw installation slots

140 DN09185846 Issue: 06A


   

Installing and Cabling Flexi Multiradio Remote Radio Installing first RRH with FPKC
Heads

Table 8 Pole diameter table related to cut location and installation slot for optimum
pole mounting
Slot 1 Slot 2 Slot 3 Slot 4
Cut 1 60-100 mm 101-140 mm N/A N/A
Cut 2 141-180 mm 181-220 mm 221-260 mm N/A
No cut N/A N/A N/A 261-300 mm

Procedure

1 Place the upper brackets around the pole and fix them with M10 screws to 30
Nm (22.13 ft-lb).

Figure 174 Placing FPKC upper brackets around a pole

Issue: 06A DN09185846 141


   

Installing first RRH with FPKC Installing and Cabling Flexi Multiradio Remote Radio
Heads

2 Insert hexagonal head screws (M8x20).

Figure 175 Inserting screws

3 Mount the lower bracket to the bottom part of the RRH. Make sure that the
lower bracket is placed so that the lifting lug hole is facing down.

Figure 176 Mounting a lower bracket

Liftinglughole

142 DN09185846 Issue: 06A


   

Installing and Cabling Flexi Multiradio Remote Radio Installing first RRH with FPKC
Heads

4 Lift the RRH to the pole so it hangs off the hexagonal head screws. Do not
tighten the screws yet.

Figure 177 Fixing lower bracket

Issue: 06A DN09185846 143


   

Installing first RRH with FPKC Installing and Cabling Flexi Multiradio Remote Radio
Heads

5 If no additional RRHs are going to be installed, fix the counterpart of the lower
bracket with two M10x315 bolts.

Figure 178 Fixing counterpart of a lower bracket

6 Tighten the hexagonal head screws on the upper brackets.

Figure 179 Tightening screws on an upper bracket

144 DN09185846 Issue: 06A


   

Installing and Cabling Flexi Multiradio Remote Radio Installing first RRH with FPKC
Heads

Example

Click here to watch a video on how to install the RRH.

g Note: The video serves as a procedure overview only. For full instructions always refer
to the steps in Installing first RRH with FPKC.

Issue: 06A DN09185846 145


   

Installing a second RRH with FPKC Installing and Cabling Flexi Multiradio Remote Radio
Heads

23 Installing a second RRH with FPKC


These instructions show the installation procedure for the second Remote Radio Heads
using FPKC Mounting Kit.

Purpose
Flexi Pole Mounting Kit is required for mounting modules on poles. FPKC is designed for
poles between 60 mm (2.4 in) and 300 mm (11.8 in) in diameter.
There is no need to use thread-locking compound or lock nuts when installing the FPKC.

Procedure

1 Insert hexagonal head screws to the upper brackets. Do not tighten the screws
yet.

Figure 180 Inserting screws to upper brackets

146 DN09185846 Issue: 06A


   

Installing and Cabling Flexi Multiradio Remote Radio Installing a second RRH with FPKC
Heads

2 Fix the lower bracket to the bottom part of the RRH.

Figure 181 Fixing the lower bracket to a RRH

Liftinglughole

Issue: 06A DN09185846 147


   

Installing a second RRH with FPKC Installing and Cabling Flexi Multiradio Remote Radio
Heads

3 Lift the RRH to the pole so it hangs off the screws. Do not tighten the screws
yet.

Figure 182 Lifting RRH to a pole

4 Tighten the hexagonal head screws on the upper brackets to 20 Nm (14.75 ft-
lb).

Figure 183 Tightening screws on an upper bracket

148 DN09185846 Issue: 06A


   

Installing and Cabling Flexi Multiradio Remote Radio Installing a second RRH with FPKC
Heads

5 Fix the lower brackets of the first and second FPKC together with two M10x315
bolts.

Figure 184 Fixing a lower bracket

Example

Click here to watch a video on how to install the RRH.

g Note: The video serves as a procedure overview only. For full instructions always refer
to the steps in Installing a second RRH with FPKC.

Issue: 06A DN09185846 149


   

Installing additional Remote Radio Heads onto the Installing and Cabling Flexi Multiradio Remote Radio
same side with FPKC Heads

24 Installing additional Remote Radio Heads


onto the same side with FPKC
These instructions show the installation procedure for the additional Remote Radio
Heads using FPKC Mounting Kit.

Purpose
Flexi Pole Mounting Kit is required for mounting modules on poles. FPKC is designed for
poles between 60 mm (2.36 in.) and 300 mm (11.81 in.) in diameter.
There is no need to use thread-locking compound or lock nuts when installing the FPKC.

Procedure

1 Install two upper brackets perpendicularly to the first and second FPKC using
hexagonal socket-head screws. Secure the screws with M8 nuts.

Figure 185 Installing an upper bracket

Liftinglughole

150 DN09185846 Issue: 06A


   

Installing and Cabling Flexi Multiradio Remote Radio Installing additional Remote Radio Heads onto the
Heads same side with FPKC

2 Insert hexagonal head screws to the upper brackets.

Figure 186 Inserting screws to an upper bracket

3 Fix a lower bracket to the bottom part of the RRH.

Figure 187 Fixing lower bracket to a RRH

Liftinglughole

Issue: 06A DN09185846 151


   

Installing additional Remote Radio Heads onto the Installing and Cabling Flexi Multiradio Remote Radio
same side with FPKC Heads

4 Lift the RRH to the pole so that it hangs off the hexagonal head screws.

Figure 188 Lifting RRH to a pole

152 DN09185846 Issue: 06A


   

Installing and Cabling Flexi Multiradio Remote Radio Installing additional Remote Radio Heads onto the
Heads same side with FPKC

5 If no additional RRHs are going to be installed, fix the counterpart of the lower
bracket with two M8x30 Allen screws with Nyloc nut and tighten them to 20 Nm
(14.75 ft-lb.).

Figure 189 Fixing counterpart of a lower bracket

6 Tighten the hexagonal head screws on the upper brackets.

Figure 190 Tightening screws on an upper bracket

Issue: 06A DN09185846 153


   

Installing additional Remote Radio Heads onto the Installing and Cabling Flexi Multiradio Remote Radio
same side with FPKC Heads

Figure 191 Third RRH installed

154 DN09185846 Issue: 06A


   

Installing and Cabling Flexi Multiradio Remote Radio Installing additional Remote Radio Heads onto the
Heads same side with FPKC

7 To install fourth RRH follow steps 1 to 4 and then fix the brackets together with
two M8x30 Allen screws with Nyloc nuts.

Figure 192 Installing fourth RRH

Example

Click here to watch a video on how to install the RRH.

g Note: The video serves as a procedure overview only. For full instructions always refer
to the steps in Installing additional Remote Radio Heads onto the same side with FPKC.

Issue: 06A DN09185846 155


   

Installing additional Remote Radio Heads onto opposite Installing and Cabling Flexi Multiradio Remote Radio
sides with FPKC Heads

25 Installing additional Remote Radio Heads


onto opposite sides with FPKC
These instructions show the installation procedure for the additional Remote Radio
Heads using FPKC Mounting Kit.

Purpose
Flexi Pole Mounting Kit is required for mounting modules on the pole. FPKC is designed
for poles between 60 mm (2.36 in) and 300 mm (11.81 in) in diameter.
There is no need to use thread-locking compound or lock nuts when installing the FPKC.

Procedure

1 Install an upper bracket perpendicularly to the first and second FPKC using
hexagonal socket-head screws and secure screws with M8 nuts.

Figure 193 Installing upper bracket

Liftinglughole

156 DN09185846 Issue: 06A


   

Installing and Cabling Flexi Multiradio Remote Radio Installing additional Remote Radio Heads onto opposite
Heads sides with FPKC

2 Insert hexagonal head screws to the upper brackets.

Figure 194 Inserting screws to the upper brackets

3 Fix a lower bracket to the bottom part of the RRH.

Figure 195 Fixing lower bracket to RRH

Liftinglughole

Issue: 06A DN09185846 157


   

Installing additional Remote Radio Heads onto opposite Installing and Cabling Flexi Multiradio Remote Radio
sides with FPKC Heads

4 Lift the RRH to the pole so that it hangs off the hexagonal head screws.

Figure 196 Lifting RRH to the pole

158 DN09185846 Issue: 06A


   

Installing and Cabling Flexi Multiradio Remote Radio Installing additional Remote Radio Heads onto opposite
Heads sides with FPKC

5 If no additional RRHs are going to be installed, secure the counterpart of the


lower bracket with two M8x30 Allen screws with Nyloc nuts and tighten them to
20 Nm (14.75 ft-lb).

Figure 197 Securing counterpart of lower bracket

Issue: 06A DN09185846 159


   

Installing additional Remote Radio Heads onto opposite Installing and Cabling Flexi Multiradio Remote Radio
sides with FPKC Heads

6 Tighten the hexagonal head screws on the upper brackets.

Figure 198 Tightening screws on upper bracket

160 DN09185846 Issue: 06A


   

Installing and Cabling Flexi Multiradio Remote Radio Installing additional Remote Radio Heads onto opposite
Heads sides with FPKC

7 To install a fourth RRH, follow steps 1 to 4 and then secure the brackets
together with two M8x30 Allen screws with Nyloc nuts.

Figure 199 Installing fourth RRH

Example

Click here to watch a video on how to install the RRH.

g Note: The video serves as a procedure overview only. For full instructions always refer
to the steps in Installing additional Remote Radio Heads onto opposite sides with
FPKC.

Issue: 06A DN09185846 161


   

Flexi RRH 2TX external alarm connection Installing and Cabling Flexi Multiradio Remote Radio
Heads

26 Flexi RRH 2TX external alarm connection


These instructions provide information on external alarm connection of Flexi RRH 2TX.
Alarm cables
The following alarm cables are available for Flexi RRH 2TX:
• Flexi System Alarm Cable 15 m (FSAC) 472284A
• Flexi System Alarm Cable 2.5 m (FSAD) 472563A

Figure 200 Flexi System Alarm Cable for Flexi RRH 2TX

Connector1
SubD37
Connector2
MDR14

Pin1

Wiring
Conn.1 Conn.2 Pairno:Color Signal
Pinno. Pinno.
25 1 1:White GND
7 2 1:Blue EXT Alarm(0)
31 3 2:White GND
32 4 2:Orange GND
8 5 3:White EXT Alarm(1)
26 6 3:Green GND
29 7 4:White GND
9 8 5:White EXT Alarm(2)
27 9 5:Gray GND
28 10 6:Red GND
10 11 6:Blue EXT Alarm(3)
36 12 7:Red GND
19 13 7:Orange 5VEAC
30 14 4:Brown GND
External alarms (EAC) interface
See the table below for the pinout of the external alarms (EAC) interface. Sub D 37 is
connected to Flexi System External Alarm (FSEB) and MDR 14 to the RRH bottom. If an
alarm connection box other than FSEB is used, cut off the Sub D 37 connector and
connect the wires according to the table below.
Table 9 Flexi RRH 2 TX EAC pinout

Connector 1 (Sub D Connector 2 (MDR Signal Pair No.: Color


37) Pin No. 14) Pin No.

25 1 GND 1: White

7 2 EXT_ALARM (0) 1: Blue

162 DN09185846 Issue: 06A


   

Installing and Cabling Flexi Multiradio Remote Radio Flexi RRH 2TX external alarm connection
Heads

Table 9 Flexi RRH 2 TX EAC pinout (Cont.)

Connector 1 (Sub D Connector 2 (MDR Signal Pair No.: Color


37) Pin No. 14) Pin No.

31 3 GND 2: White

32 4 GND 2: Orange

8 5 EXT_ALARM (1) 3: White

26 6 GND 3: Green

29 7 GND 4:White

9 8 EXT_ALARM (2) 5: White

27 9 GND 5: Gray

28 10 GND 6: Red

10 11 EXT_ALARM (3) 6: Blue

36 12 GND 7: Red

19 13 5V_EAC 7: Orange

30 14 GND 4: Brown

Issue: 06A DN09185846 163