Download as pdf or txt
Download as pdf or txt
You are on page 1of 64

APPENDIX 1

Standard Detail Drawings

Township of King
Design Criteria and Standard Detail Drawings
Township of King Design Criteria and Standard Detail Drawings

APPENDIX 1 – STANDARD DETAIL DRAWINGS

Drawing Title Revision


No. Date
KS-171 Typical Drop Structure for Storm Manhole Feb. 2017
KS-174 Beehive Catchbasin - Frame and Cover April 2015
KS-175 Service Location Single Family Residential Oct. 2016
KS-176 Service Location Semi-Detached Residential Oct. 2016
KS-177 Storm Sewer Service Connection Sep. 2016
KS-178 Storm Sewer Riser Connection Nov. 2009
KS-179 Townhouse Service Connections April 2015
KS-180 Bedding Detail for Plastic Sanitary Service Connections Nov. 2009
KS-190 Sanitary Sewer House Connections Nov. 2015
KS-191 Sanitary Sewer Riser Connections for Residential Developments Mar. 2012
KS-193 Sanitary Sewer Cleanouts June 2016
KS-194 Sanitary Sewer Connections June 2016
KS-202 20.0m Estate Residential Roadway Feb. 2017
KS-205 20.0m Local Roadway Feb. 2017
KS-210 26.0m Collector Roadway (incl. Bike Lanes) Mar. 2017
KS-218 Typical Cul-De-Sac for Residential Streets Nov. 2009
KS-219 Typical Cul-De-Sac for Industrial Streets Nov. 2009
KS-220 Temporary Turning Circle for Residential Streets Nov. 2009
KS-224 Typical Bulb Detail for Residential Crescents Mar. 2016
KS-231 Concrete Sidewalk May 2014
KS-302 Precast Concrete Splash Pad Detail Nov. 2009
KS-313 Wood Privacy Fence Nov. 2015
KS-320 Pedestrian Walkway In Urban Setting Nov. 2009
KS-331 Traffic Sign Details and Pavement Markings Mar. 2016
KS-335 Stormwater Management Facility Warning Sign May 2016
KS-340 Standard Driveway Culvert Nov. 2009
KS-341 Driveway Approach Paving for Residential Driveways Nov. 2015
KS-342 Driveway Approach Paving Commercial, Industrial & Apartments Nov. 2015
KS-346 Joint Use Utility Trench Dec. 2015
KS-400 Typical Legend for Lot Grading Plan Nov. 2015
KS-401 Front Lot Drainage Nov. 2009
KS-402 Rear Lot Drainage Nov. 2009
KS-403 Rear Lot Drainage for Walkout or Back Split House Nov. 2009
KS-404 Front Lot Drainage for Front Split House Nov. 2009
KS-500 Drawing Title Block Nov. 2009
KS-701 Typical Pole and Luminaire (Decorative) Feb. 2017

Last Update: March 2017 1-1


Township of King Design Criteria and Standard Detail Drawings

APPENDIX 1 – STANDARD DETAIL DRAWINGS

Drawing Title Revision


No. Date
KS-801 Watermain Trench and Bedding Details Nov. 2015
KS-802 Watermain Trench Detail Under Watercourse Nov. 2009
KS-803 50mm Blow-off for Watermain with Restrained Joints Oct. 2016
KS-804 Methods of Insulating Watermains Nov. 2009
KS-805 Supports for Watermains and Sewers Crossing Watermain Nov. 2009
Trenches
KS-820 19mm to 25mm Water Meter Installation in Building Jan. 2017
KS-830 Joint Restraining Length for P.V.C Pipe Nov. 2015
KS-840 150mm to 250mm Gate Valve & Box Nov. 2009
KS-841 Semi-precast Concrete Valve Chamber for 300mm Pipe or Jan. 2017
Larger
KS-843 Air Release Chamber Feb. 2015
KS-844 Combination Air & Valve Chamber-Model Nov. 2015
KS-845 Water Meter Installation in Chamber (For Combined Fire & April 2015
Domestic)
KS-846 Water Service Connections for Single ICI Building April 2015
KS-847 Water Meter Chamber Details (50 mm Service Line) May 2015
KS-851 Water Service (20 mm to 50 mm) Oct. 2016
KS-854 Corrosion Protection for Hydrant Cut Into an Existing D.I. or C.I Nov. 2015
Watermain
KS-860 Tracer Wire Arrangement at Valve Box for P.V.C. or C.P.P Nov. 2009
Watermain
KS-870 Corrosion Protection for Tracer Wires on P.V.C. or C.P.P Nov. 2009
Watermain
KS-871 Corrosion Protection for Valves & Fittings on Non-ferrous Pipe Nov. 2009
KS-873 Corrosion Protection for Existing Ferrous Watermain Connected Nov. 2009
to Proposed Non-Ferrous Watermain
KS-874 Corrosion Protection for Hydrant Assembly on Non-Ferrous Pipe Nov. 2015
KS-875 Corrosion Protection for Hydrants Off of New D.I Watermain Nov. 2015
KS-877 Watermain Configuration for Dead End Cul-De-Sacs Sep. 2016
KS-878 Side View of Sampling Station Installation Oct. 2016
KS-900 Benchmark Monument Details Jan. 2017

Last Update: March 2017 1-2


NOTES:
1. DROP PIPE TO BE ONE SIZE SMALLER THAN INLET UNLESS
OTHERWISE NOTED. MIN= 200mm; MAX= 750mm
2. DROP PIPE TO HAVE CROWN LEVEL WITH OUTLET PIPE AND BENCHED
TO CROWN.
3. DROP PIPE TO BLEND WITH FLOW.
4. DROP STRUCTURE TO BE ENCASED IN A MINIMUM OF 150mm OF 20
MPa CONCRETE AND DOWELLED TO MAINTENANCE HOLE WITH 12mm
DIA. DOWELS, 450mm LONG, EITHER SIDE OF DROP PIPE AND AT
300mm C TO C.
5. MAXIMUM VELOCITIES SHOWN IN TABLE INDICATE MAXIMUM VELOCITY
IN INCOMING PIPE WITH NO OVERSHOOTING.
6. WHEN USED ON STORM SEWERS 375mm DIA. OR LARGER, A 12 DIA.
CONCRETE STOPPER MAY BE INSERTED IN THE INVERT OF THE MAIN
LINE AS INDICATED.
7. ADJUSTMENT IN 'D' AND 'L' TO BE MADE WITH PLAIN END STRAIGHT
PIPE.
8. WHERE 'Y' FITTING JOINS FIRST PIPE, A 300mm WIDE BY 15mm THICK 20
MPa CONCRETE COLLAR IS TO BE CONSTRUCTED.
9. ALL CONCRETE IN DROP STRUCTURE TO BE 20 MPa AT 28 DAYS.
10. MINIMUM DIMENSIONS BASED ON USE OF STANDARD CONCRETE
FITTINGS.
11. ALL DIMENSIONS ARE SUBJECT TO MANUFACTURER'S PERMISSIBLE
VARIATIONS.

APPROVED DATE OF ISSUE

TOWNSHIP OF KING M.C. FEB. 2017

REVISION DRAWING No.

TYPICAL DROP STRUCTURES FOR


STANDARD STORM MANHOLES DATE OF REVISION KS-171
44
600

44
600

32

55 64
119
820

76

29
305 305
64
623

305
655
88
820

51

305
51
38
32
51

NOTES:

1. ALLOWABLE TOLERANCE: DIMENSIONS 300mm OR LESS + 3mm


DIMENSIONS OVER 300mm UP TO AND INCLUDING 900mm +6mm
2.. THE INITIALS OR MARK OF THE MANUFACTURER ARE TO BE DISTINCTLY
CAST IN RAISED LETTERS ON BOTH FRAME AND COVER

3. STEEL FOR HINGE PINS TO BE AS ASTM DESIGNATION A-7 OR EQUIVALENT

4. CAST IRON TO CONFORM TO ASTM DESIGNATION A-48-74 CLASS 30-C

5. DIMENSIONS IN mm EXCEPT AS NOTED

APPROVED DATE OF ISSUE

TOWNSHIP OF KING M.C. APRIL 2015

REVISION DRAWING No.

BEEHIVE CATCHBASIN
FRAME and COVER
DATE OF REVISION KS-174
Lot CL CL Lot

SANITARY SERVICE - 125 mm

SANITARY SERVICE - 125 mm


STORM SERVICE - 150 mm

STORM SERVICE - 150 mm


WATER SERVICE - 20 mm

WATER SERVICE - 20 mm
LEGEND
B - BELL
H - HYDRO
C - CABLE TV
P/L

P/L

P/L
0.6 m 0.6 m

1.5 m 1.5 m

1.5 m
GAS
GAS
H. B. & C
H. B. & C

H. B. & C
H. B. & C
CURB STOP VALVE
AT STREETLINE

MANHOLE

STORM SEWER

CL OF STREET
MANHOLE

SANITARY SEWER

WATERMAIN

HYDRANT

NOTES:

1. SERVICES TO EXTEND 1.5m INSIDE PROPERTY LINE AND CAPPED.

REFER TO NOTE 7 2. UNDER NO CIRCUMSTANCES SHALL SERVICES CROSS ONE ANOTHER.


SANITARY SERV.

3.
WATER SERV.

STORM SERV.

FINISHED GRADE
INSTALLED AT A MINIMUM GRADE OF 2% FROM THE STORM SEWER TO
3 1 3 1 THE BUILDING ENVELOPE.
1.8m max.
1.7m min.

1 1
4.
INSTALLED AT A MINIMUM GRADE OF 2% FROM THE SANITARY SEWER TO
3.0m max.
2.5m min.

1.5m 0.6m
THE BUILDING ENVELOPE.
5. ALL UNDERGROUND SERVICE CABLES TO BE PLACED A MINIMUM 1.0m
1.2m max.

BELOW FINISHED GRADE OF LOTS.


600mm min. 6. ALL DIMENSIONS ARE IN METRES EXCEPT WHERE NOTED.
7. TRENCH DIMENSIONS AND SLOPING OF WALLS TO BE UNDERTAKEN IN
ACCORDANCE WITH REQUIREMENTS OF THE OCCUPATIONAL HEALTH
TYPICAL TRENCH SECTION AND SAFETY ACT, AS AMENDED.
N.T.S
8. CURB STOPS SHALL NOT BE LOCATED WITHIN DRIVEWAYS (0.6m MINIMUM
OFFSET).

APPROVED DATE OF ISSUE

TOWNSHIP OF KING M.C. JAN. 1990

REVISION DRAWING No.

SERVICE LOCATION
SINGLE FAMILY RESIDENTIAL
DATE OF REVISION KS-175
OCT. 2016
CL
CL SEMI-DETACHED LOT CL SEMI-DETACHED
LOT LOT

SANITARY SERVICE - 125 mm

SANITARY SERVICE - 125 mm


STORM SERVICE - 150 mm

STORM SERVICE - 150 mm


WATER SERVICE - 20 mm

WATER SERVICE - 20 mm
LEGEND
B - BELL
H - HYDRO
C - CABLE TV

P/L
P/L

0.9m 0.5m 1.0m

LOT LINE
H. B. & C

GAS
0.6 m 0.6 m

1.5 m 1.5 m
H. B. & C

H. B. & C
GAS

GAS
1.5 m

1.5 m
SHUT-OFF VALVE SHUT-OFF VALVE
AT STREETLINE AT STREETLINE

MANHOLE

STORM SEWER

CL OF STREET
MANHOLE

SANITARY SEWER

WATERMAIN

HYDRANT

CL SEMI-DETACHED
LOT

REFER TO NOTE 7
SANITARY SERV.

NOTES:
WATER SERV.
STORM SERV.

FINISHED GRADE

1 3 3 1 1. SERVICES TO EXTEND 1.5m INSIDE PROPERTY LINE AND CAPPED


1.8m max.
1.7m min.

1 1
2. UNDER NO CIRCUMSTANCES SHALL SERVICES CROSS ONE ANOTHER.
3.0m max.
2.5m min.

0.6m 1.5m 3.
INSTALLED AT A MINIMUM GRADE OF 2% FROM THE STORM SEWER TO
THE BUILDING ENVELOPE.
1.2m max.

4.
600mm min. INSTALLED AT A MINIMUM GRADE OF 2% FROM THE SANITARY SEWER TO
THE BUILDING ENVELOPE.
5. ALL UNDERGROUND SERVICE CABLES TO BE PLACED A MINIMUM 1.0m
TYPICAL TRENCH SECTION
N.T.S
BELOW FINISHED GRADE OF LOTS.
6. ALL DIMENSIONS ARE IN METRES EXCEPT WHERE NOTED.
7. TRENCH DIMENSIONS AND SLOPING OF WALLS TO BE UNDERTAKEN IN
ACCORDANCE WITH REQUIREMENTS OF THE OCCUPATIONAL HEALTH
AND SAFETY ACT, AS AMENDED.
8. CURB STOPS SHALL NOT BE LOCATED WITHIN DRIVEWAYS
(0.6m MINIMUM OFFSET).

APPROVED DATE OF ISSUE

TOWNSHIP OF KING M.C. JAN. 1990

REVISION DRAWING No.

SERVICE LOCATION
SEMI DETACHED RESIDENTIAL
DATE OF REVISION KS-176
OCT. 2016
STREET LINE
CL SANITARY SEWER
CL STORM SEWER

CL ROAD
1.50m 1.50m

600mm MIN.
SUITABLE DEPTH TO
ALLOW FOR CONNECTION
TO HOUSE WEEPING TILE
(2.30m TO 2.80m)

2%

2% MIN GRADE
WATERTIGHT PLUG
1.50m
75mm - 20mm
CRUSHER RUN LIMESTONE
COMPACTED GRANULAR
MATERIAL
SERVICE
CONNECTION
PIPE

MANUFACTURED TEE
OR 'KOR-N-TEE'
CONNECTOR

CRUSHER RUN LIMESTONE


PIPE SIZES
450mm OR
LESS

ORIGINAL SEWER BEDDING

SAND
150mm

1/2 HEIGHT OF PIPE

BACKFILL
SERVICE
CONNECTION
CONNECTION PIPE PIPE

'KOR-N-TEE'
CONNECTION OR
BELL TO REST
78.8mm

ON MAIN SEWER

SADDLE SHALL NOT


20mm CRUSHER PROJECT INTO
RUM LIMESTONE MAIN SEWER
CRUSHER RUN LIMESTONE
SPECIFIED BEDDING
PIPE SIZES SADDLE TO BE
525mm TO FIRMLY MORTARED
750mm TO MAIN SEWER

ORIGINAL SEWER BEDDING

NOTES:

1. STORM SERVICE CONNECTION PIPE TO BE FITTED WITH APPROVED RUBBER GASKET JOINTS. SERVICE
CONNECTION
2. IF CONTRACTOR TUNNELS UNDER WATERMAIN, MINIMUM LENGTH OF PIPE
TUNNEL TO BE 1.8m AND ALL VOIDS TO BE FILLED WITH H.L.8 BLEND
CLEAR STONE.
'KOR-N-TEE'
CONNECTION OR
3. RISERS TO BE INSTALLED WHERE SPECIFIED ON THE ENGINEERING BELL TO REST
DRAWINGS OR WHEN DEPTH TO TOP OF SEWER EXCEEDS 4.5m. ON MAIN SEWER
(SEE KS-178)
4. SERVICE CONNECTION TO BE INSTALLED IN A STRAIGHT LINE FROM BELL SHALL NOT
PROJECT INTO
SEWER TO STREETLINE. MAIN SEWER
5. ALL DIMENSIONS ARE IN MILLIMETRES OR METRES.
CRUSHER RUN LIMESTONE
6. FLOOR DRAIN CONNECTIONS WITHIN BUILDING ENVELOPE SHALL NOT BE
CONNECTED TO STORM SEWER SERVICE. PIPE SIZES
BELL TO BE FIRMLY
7. AS AN ALTERNATIVE 'KOR-N-TEE' CONNECTORS MAY BE USED FOR 150mm MORTARED TO MAIN
GREATER
SEWER

8. TRENCH DIMENSIONS AND SLOPING OF WALLS TO BE UNDERTAKEN IN


ACCORDANCE WITH REQUIREMENTS OF THE OCCUPATIONAL HEALTH
ORIGINAL SEWER BEDDING
AND SAFETY ACT, AS AMENDED.

APPROVED DATE OF ISSUE

TOWNSHIP OF KING M.C. FEB. 1980

REVISION DRAWING No.

STORM SEWER SERVICE


CONNECTION
DATE OF REVISION KS-177
SEP. 2016
CONCRETE CONNECTION
MIN. SLOPE 2%

150mm 150mm
MIN. MIN.
1/8 BEND

CONCRETE RISER 15 MPa


(LENGTH VARIES TO SUIT) CONC. BEDDING TO GO
TO 1st JOINT WITHIN
UNDISTURBED GROUND

MANUFACTURED TEE
CONCRETE ENCASEMENT
150mm

UNDISTURBED
GROUND
150mm

A SEWER MAIN
TO NEAREST JOINT TO NEAREST
JOINT
CONCRETE ENCASEMENT

SECTION A-A

NOTES:

1. ALL CONCRETE BEDDING TO BE MINIMUM 15 MPa.


2.
THE MAIN IS TO BE MADE BY MEANS OF A MANUFACTURED TEE.
3. RISERS MUST NOT EXCEED 3.0m IN DEPTH.
4. RISER CONNECTION DETAIL MUST BE USED WHEN DEPTH TO INVERT OF
SEWER MAIN EXCEEDS 4.5m.
5. ALL DIMENSIONS ARE IN MILLIMETRES AND METRES.
6. POLYVINYL CHLORIDE (SDR 28) IS AN APPROVED EQUIVALENT TO
CONCRETE PIPE FOR SERVICE CONNECTIONS. WHERE P.V.C. PIPE IS
USED, BEDDING MATERIAL SHALL BE HL 8 BLEND CLEAR STONE.
7. TRENCH DIMENSIONS AND SLOPING OF WALLS TO BE UNDERTAKEN IN
ACCORDANCE WITH REQUIREMENTS OF THE OCCUPATIONAL HEALTH
AND SAFETY ACT, AS AMENDED.

APPROVED DATE OF ISSUE

TOWNSHIP OF KING M.C. FEB. 1980

REVISION DRAWING No.

STORM SEWER RISER CONNECTION DATE OF REVISION KS-178


NOV. 2009
COMMON LOT LINE COMMON LOT LINE COMMON LOT LINE

CL UNIT CL UNIT

SANITARY SERVICE - 125mm PVC

SANITARY SERVICE - 125mm PVC


STORM SERVICE - 150mm PVC
WATER SERVICE - 20mm

WATER SERVICE - 20mm


LEGEND
B - BELL
H - HYDRO
C - CABLE TV

0.6m 0.6m

1.5m MIN. 1.5m MIN.

1.0m 0.5m 0.9m 0.9m 0.5m 1.0m


H. B. & C

H. B. & C
GAS

GAS
1.5m

1.5m
STREET LINE

SHUT-OFF VALVE PVC TEST FITTING PVC TEST FITTING SHUT-OFF VALVE
AT STREETLINE A A AT STREETLINE

PVC TEST FITTING

MANHOLE

STORM SEWER

CL OF STREET
MANHOLE

SANITARY SEWER

WATERMAIN

HYDRANT

CL UNIT
REFER TO NOTE 8
SANITARY SERV.

NOTES:
WATER SERV.
STORM SERV.

FINISHED GRADE

1 3 3 1
1. SERVICES TO EXTEND 1.5m INSIDE PROPERTY LINE.
1.8m MAX.
1.7m MIN.

1 1
2. UNDER NO CIRCUMSTANCES SHALL SERVICES CROSS ONE ANOTHER.
3.0m MAX.
2.5m MIN.

0.6m 1.5m MIN. 3.


SERVICE LATERAL.
1.2m MAX.

4.
INSTALLED AT A MINIMUM GRADE OF 2% FROM THE STORM SEWER TO
600mm MIN.
THE BUILDING ENVELOPE.
5.
SECTION A-A
INSTALLED AT A MINIMUM GRADE OF 2% FROM THE SANITARY SEWER TO
N.T.S THE BUILDING ENVELOPE.
6. ALL UNDERGROUND SERVICE CABLES TO BE PLACED A MINIMUM 1.0m
BELOW FINISHED GRADE OF LOTS.
7. ALL DIMENSIONS ARE IN METRES EXCEPT WHERE NOTED.
8. TRENCH DIMENSIONS AND SLOPING OF WALLS TO BE UNDERTAKEN IN
ACCORDANCE WITH REQUIREMENTS OF THE OCCUPATIONAL HEALTH
AND SAFETY ACT, AS AMENDED.

APPROVED DATE OF ISSUE

TOWNSHIP OF KING M.C. NOV. 2010

REVISION DRAWING No.

SERVICE LOCATION
MULTI / TOWN HOUSE SERVICE CONNECTION DATE OF REVISION KS-179
APRIL 2015
MINIMUM 450mm

TRENCH DIMENSIONS AND SLOPING


OF WALLS TO BE UNDERNEATH IN
ACCORDANCE WITH REQUIREMENTS
OF THE OCCUPATIONAL HEALTH AND
SAFETY ACT, AS AMENDED.

NATIVE MATERIAL COMPACTED


TO 95% PROCTOR DENSITY

MINIMUM 300mm
SAND BACKFILL COMPACTED
TO 98% PROCTOR DENSITY

Bc

05 Bc
100mm
MIN.

P.V.C. SERVICE CONNECTION 20mm CRUSHER RUN LIMESTONE


STANDARD DIMENSION RATIO TO SPRINGLINE OF PIPE COMPACTED
NOT TO EXCEED SDR 28 TO 98% PROCTOR DENSITY TO
WALLS OF TRENCH

APPROVED DATE OF ISSUE

TOWNSHIP OF KING M.C. JAN. 1990

REVISION DRAWING No.

BEDDING DETAIL FOR PLASTIC


SANITARY SEWER SERVICE CONNECTIONS DATE OF REVISION KS-180
NOV. 2009
PROPERTY LINE

ROAD ALLOWANCE

MAX. 3.0m
MIN. 2.5m
CENTRE OF
SHORT LENGTH OF
P.V.C. SDR 28

MINIMUM 3.0m
MINIMUM 2% GRADE
MAXIMUM 10% GRADE
MAXIMUM 4.5m

'A'
SEE
NOTE 4

CONN. 3%
INVERT MAX 125mm x 125mm CAST IRON
TEST FITTING (CROWLE INDUSTRIES
OR APPROVED EQUIVALENT)
PIPE COUPLING
CONNECTION BRANCH
(SEE NOTE 2)
FULL LENGTH OF
P.V.C. SDR 28

'B'

'A' - MINIMUM 75mm. MAXIMUM 125mm OBVERT TO OBVERT


CONNECTION 'B' - MAXIMUM 300mm OBVERT TO OBVERT
INVERT

STAINLESS STEEL RING SEAL ACCORDING TO


NUT AND WASHER MANUFACTURERS
SPECIFICATIONS

9.525 STUD AND NUT


STAINLESS (2 REQUIRED)
STEEL STRAP
CEMENT MORTAR

SECTION 'A-A'

CAST IRON SADDLE BRANCH FOR


CONNECTION TO EXISTING MAINS OTHER 31.750 DEPTH
THAN P.V.C. OR A.B.S. TRUSS PIPE 'TAMPIN'
EXPANSION MACHINE INSIDE CIRCUMFERENCE
JOINT CUT OPENING OF PIPE

NOTES:

1. IN NEW SUBDIVISIONS THE SANITARY SEWER AND WATER SERVICE CONNECTIONS ARE TO
PIPE COUPLING BE INSTALLED IN COMMON TRENCHES AS PER STANDARD DETAILS KS-175 AND KS-176.
2. IN NEW SUBDIVISIONS ALL CONNECTIONS TO THE SEWERS ARE TO BE MADE WITH A FACTORY
MANUFACTURED TEE. FOR CONNECTIONS TO EXISTING SANITARY SEWERS, OTHER THAN
P.V.C. OR A.B.S. TRUSS PIPE, A SADDLE CONNECTION MAY BE USED. MORTAR-ON SADDLES

SEWERS ARE TO BE MADE WITH A FACTORY MANUFACTURED TEE. CONNECTIONS TO


EXISTING A.B.S. PIPE ARE TO BE MADE WITH A SOLVENT WELDED SADDLE.
125mm P.V.C. SDR 28 3.
WHEN LATERAL INTERSECTS SEWER MAIN AT AN ACUTE ANGLE.
SADDLE BRANCH 4. THE SEWER CONNECTION SHALL BE LAID FROM THE MAIN TO 1.5m BEYOND THE PROPERTY
LINE IN NEW SUBDIVISIONS ONLY.
SEWER MAIN
5. THE ENDS OF ALL SEWER PIPE MUST BE MACHINED. ALL CUTTING AND MACHINING TO BE
DONE BY THE CONTRACTOR.
6. A COUPLING SHALL BE INSTALLED AT DEAD ENDS AND SHALL BE PLUGGED USING A WATER
TIGHT PLUG.
7.
'A' 'A'
8. PIPE COUPLING TO BE 'RING-TITE' OR EQUIVALENT P.V.C. BELL AND SPIGOT JOINT WITH
RUBBER GASKETS.
9. REFER TO STANDARD KS-180 FOR BEDDING REQUIREMENTS FOR P.V.C. SERVICE
CONNECTIONS.
10. WHEN MORTAR-ON SADDLES ARE USED, A MACHINE CUT OPENING IS TO BE MADE IN THE
TOP VIEW SANITARY SEWER WITH A CORING MACHINE.
11. ALL DIMENSIONS ARE IN MILLIMETRES EXCEPT WHERE NOTED.

APPROVED DATE OF ISSUE

TOWNSHIP OF KING M.C. JAN. 1990

REVISION DRAWING No.

SANITARY SEWER HOUSE CONNECTIONS


(125 & 150mm PIPE) DATE OF REVISION KS-190
NOV. 2015
CENTRELINE PAVEMENT ELEVATION

PROPERTY LINE
150mm MAXIMUM DEFLECTION FOR
BEND, S.D.R. 28

3.0m MAXIMUM
2.5m MINIMUM
EVERY 4.0m LENGTH OF PIPE

P.V.C. PIPE
S.D.R. 28

CENTRELINE OF
MAIN SEWER
ROAD ALLOWANCE
CENTRE OF

MINIMUM 2% GRADE
MAXIMUM 10% GRADE
SEE
2.0m MAXIMUM

NOTE 3

TYPE '1' BEDDING


150mm MIN.

NOTES:
UNDISTURBED GROUND
1. RISER CONNECTIONS TO BE USED WHEN MAIN SEWER DEPTH IS
MINIMUM 75mm GREATER THAN 4.5m FROM CENTRELINE PAVEMENT ELEVATION TO
OBVERT OF MAIN SEWER.
FACTORY MANUFACTURED 'T'
2. RISER CONNECTION TO BE USED WHEN WALLS OF EXCAVATION ARE
150mm MIN.
O.D. +

H.L. 8 BLEND CLEARSTONE


3. IN NEW SUBDIVISIONS, THE SEWER CONNECTION SHALL BE LAID FROM
THE MAIN TO 1.5m BEYOND THE PROPERTY LINE AND PLUGGED WITH
CROWLE - 125mm x 125mm TEST FITTING.
O.B. +
600mm MIN. 4. ALL CUTTING AND MACHINING TO BE DONE BY CONTRACTOR.

SANITARY SEWER RISER CONNECTION - LESS THAN 5.0m DEEP 5. 'KWICK' COUPLING OR APPROVED EQUAL SHALL BE USED WHEN
CONNECTION IS MADE TO EXISTING LATERAL.
6. ALL DIMENSIONS IN MILLIMETERES EXCEPT WHERE NOTED.

PAVEMENT ELEVATION

PROPERTY LINE
150mm MAXIMUM DEFLECTION FOR
CENTRELINE OF
MAIN SEWER

3.0m MAXIMUM
2.5m MINIMUM
EVERY 4.0m LENGTH OF PIPE
ROAD ALLOWANCE

P.V.C. PIPE
CENTRE OF

S.D.R. 28

UNDISTURBED GROUND
SEE
NOTE 3
MINIMUM 2% GRADE
TYPE '1' BEDDING MAXIMUM 10% GRADE
VARIES

CONTROLLED SETTLEMENT JOINT


NOTES:

1. RISER CONNECTIONS TO BE USED WHEN MAIN SEWER DEPTH IS


MINIMUM 75mm
150mm MIN.

GREATER THAN 4.5m FROM CENTRELINE PAVEMENT ELEVATION TO


OBVERT OF MAIN SEWER.

2. RISER CONNECTION TO BE USED WHEN WALLS OF EXCAVATION ARE

3. IN NEW SUBDIVISIONS, THE SEWER CONNECTION SHALL BE LAID FROM


150mm MIN.

THE MAIN TO 1.5m BEYOND THE PROPERTY LINE AND PLUGGED WITH
O.D. +

FACTORY MANUFACTURED TEE


(SEE NOTE 7) WATERTIGHT PLUG.
H.L. 8 BLEND CLEARSTONE 4. ALL CUTTING AND MACHINING TO BE DONE BY CONTRACTOR.
O.B. +
600mm MIN. 5. APPROVED COUPLING SHALL BE USED WHEN CONNECTION IS MADE TO
AN EXISTING LATERAL.
SANITARY SEWER RISER CONNECTION - DEEP LATERAL 6. 'WHEN CONNECTING TO AN EXISTING SANITARY SEWER, CRUSHER RUN
LIMESTONE IS TO EXTEND FROM SPRINGLINE OF THE SEWER TO TOP
OF SWEEP BEND.

7. A CONTROLLED SETTLEMENT JOINT IS TO BE USED ON RISERS OVER


5.0m HIGH.
APPROVED DATE OF ISSUE

TOWNSHIP OF KING M.C. JAN. 1990

REVISION DRAWING No.

SANITARY SEWER RISER CONNECTIONS


FOR RESIDENTIAL DEVELOPMENT DATE OF REVISION KS-191
MAR. 2012
ROAD ALLOWANCE PRIVATE PROPERTY

SWING CAP
100mm - 150mm (SEE NOTE 2)

PROPERTY LINE
BELL CLEANOUT
SEE DETAIL 'A'

125mm PIPE

BENDS
H.L. 8 STONE
FOR P.V.C. PIPE PLAN

162mm

RUBBER GASKET
'Y' BRANCH

GALVANIZED
92mm

OR BRASS

100m MINIMUM
125mm PIPE

PROFILE

SURFACE CLEANOUT
DETAIL 'A'
ROAD ALLOWANCE PRIVATE PROPERTY

NOTES:

1. FITTINGS ARE TO BE CAST IRON (CROWLE) OR PVC EQUIVALENT (PER ROYAL


INSPECTION CHAMBER).
PLAN 2. LATERALS AND CLEAN-OUTS SHALL NOT BE LOCATED IN DRIVEWAYS.
3. METAL CAP, OR PVC CAP SUITABLE FOR THE RISER PIPE WITH A METALLIC
MASS, IS ACCEPTABLE.
4. SURFACE CLEAN-OUTS SHALL BE USED ON SERVICE LATERALS 30 m LONG
(OR GREATER), OR AS DIRECTED.
5. ALL DIMENSIONS IN MILLIMETRES EXCEPT WHERE NOTED.

PROFILE

RUNNING CLEANOUT

APPROVED DATE OF ISSUE

TOWNSHIP OF KING M.C. JAN. 1990

REVISION DRAWING No.

SANITARY SEWER CLEANOUTS DATE OF REVISION KS-193


JUNE 2016
ALTERNATE CONNECTION LOCATION

FLOW
CLEAN-OUT

PIPE AT MIN 2% GRADE

LONG RADIUS BEND TO SUIT

PROPERTY LINE
LATERAL WYE

TYPICAL PLAN

SUFFICIENT TO PICK UP BASEMENT PLUMBING


WATER TIGHT CAP DETECTABLE WITH METAL DETECTOR

COVER AT THE PROPERTY LINE OR


MIN 2.50mm
CENTRELINE OF

SEE NOTE 3
MAIN SEWER

CAP OR PLUG WITH RUBBER RING JOINT

1m

125mm-MINIMUM 2% GRADE
MAXIMUM 10% GRADE

COMPACTED BEDDING MATERIAL MIN. DEPTH 100mm BELOW PIPE

ELEVATION

NOTES:

1. RISER CONNECTIONS TO BE USED ONLY WHERE SERVICE IS GREATER THAN 2M ABOVE


WYE INVERT OR WHERE APPROVED
2. MINIMUM SERVICE CONNECTION TO BE 125mm IN DIAMETER.
3. ONLY THE SANITARY SERVICE REQUIRES A CLEANOUT AT THE PROPERTY LINE.
4. SEE KS-193 FOR DETAILS OF CLEAN-OUT.

APPROVED DATE OF ISSUE

TOWNSHIP OF KING M.C. JAN. 1990

REVISION DRAWING No.

SANITARY SEWER CONNECTIONS


FOR RESIDENTIAL DEVELOPMENT DATE OF REVISION KS-194
JUNE 2016
20.0
R.O.W.

5.75 4.25 4.25 5.75

CL
CONSTRUCTION

CONCRETE CURB & GUTTER


OPSD 600.070 (TYP.)
3.75 3.75
40mm ASPHALT SURFACE COURSE HL 3 FIN. PAV'T GRADE
PLUS 0.15 MIN.
2.8 (TYP.) PLUS 0.30 MAX.
50mm ASPHALT BINDER COURSE HL 8
0.5 0.5 2.8 (TYP.)

5% MAX. HYDRO HYDRO 5% MAX.


2% MIN. VAULT VAULT 2% MIN.
2% 2%
0.3m 0.3m 0.3m
100mm TOPSOIL & SOD

100mm TOPSOIL & SOD


3% 3%
0.3 0.3
150mm GRANULAR 'A'
SOUTH OR WEST STREETLINE

(ALTERNATE)

(ALTERNATE)

NORTH OR EAST STREETLINE


TRENCH)

TRENCH)
300mm GRANULAR 'B'
KS-346

KS-346
(JOINT

(JOINT
GAS

GAS
400mm

400mm
150mm SUBDRAIN

150mm SUBDRAIN
1.5
1.6 1.0 1.0 1.6
TREE, UTILITY PEDESTAL

TREE, UTILITY PEDESTAL


STORM
& STREET LIGHT POLE

& STREET LIGHT POLE


SEWER

NOTES:

1. ALL DIMENSIONS IN METRES UNLESS NOTED.


2. ALL GRANULAR MATERIALS TO BE COMPACTED TO 100% STANDARD PROCTOR DENSITY.
3. ALL ASPHALT AND GRANULAR DEPTHS SPECIFIED ARE MINIMUM DEPTHS AND ARE
SUBJECT TO INCREASE BASED ON SOIL CONDITIONS.
4. BELL, HYDRO, COAXIAL, AND GASMAIN TO BE LOCATED IN COMMON TRENCH.
(SEE KS-346)

APPROVED DATE OF ISSUE

TOWNSHIP OF KING M.C. FEB. 1980

REVISION DRAWING No.

20.0m ESTATE RESIDENTIAL ROADWAY


8.5m PAVEMENT WIDTH DATE OF REVISION KS-202
JAN. 2017
20.0
R.O.W.

5.75 4.25 4.25 5.75

2.0 CL 2.0
CONSTRUCTION

3.75

CONCRETE CURB & GUTTER


3.75 OPSD 600.070 (TYP.)
3.10
40mm ASPHALT SURFACE COURSE HL 3
2.8 (TYP.)
0.5 1.8 HYDRANT
0.5 50mm ASPHALT BINDER COURSE HL 8 1.8 0.5
CONCRETE VALVE BOX CONCRETE
SIDEWALK (TYP.) SIDEWALK (TYP.)
HYDRO FIN. PAV'T GRADE
VAULT 5% MAX. 5% MAX. PLUS 0.15 MIN.
2% 2%
2% MIN. 2% MIN. PLUS 0.30 MAX.
2% 2%
0.3m 0.3m CURB
0.5 STOP
100mm TOPSOIL & SOD

1.80 MIN COVER


3% 3%

0.3 150mm GRANULAR 'A' 0.3


SOUTH OR WEST STREETLINE

NORTH OR EAST STREETLINE


300mm GRANULAR 'B'
(ALTERNATE)

(ALTERNATE)
400mm

400mm
TRENCH)

TRENCH)
150mm SUBDRAIN

150mm SUBDRAIN
KS-346

KS-346
(JOINT

(JOINT
GAS

GAS
TREE, UTILITY PEDESTAL
& STREET LIGHT POLE

1.5 1.5
1.6 1.0 2.0 1.0 1.6

WATERMAIN
SANITARY
SEWER
STORM COMMON 4.6
SEWER TRENCH

TREE, UTILITY PEDESTAL


& STREET LIGHT POLE
NOTES:
1. ALL DIMENSIONS IN METRES UNLESS NOTED.
2. ALL GRANULAR MATERIALS TO BE COMPACTED TO 100% STANDARD PROCTOR DENSITY.
3. ALL ASPHALT AND GRANULAR DEPTHS SPECIFIED ARE MINIMUM DEPTHS AND ARE
SUBJECT TO INCREASE BASED ON SOIL CONDITIONS.
4. BELL, HYDRO, COAXIAL, AND GASMAIN TO BE LOCATED IN COMMON TRENCH.
(SEE KS-346)

APPROVED DATE OF ISSUE

TOWNSHIP OF KING M.C. FEB. 1980

REVISION DRAWING No.

20.0m LOCAL R.O.W.


8.5m PAVEMENT, SIDEWALK ONE SIDE DATE OF REVISION KS-205
FEB. 2017
26.0
R.O.W.

CL
CONSTRUCTION
7.00 6.00 6.50 6.50

4.75 2.0 2.20 1.80 3.50 3.50 1.50 2.0 4.50


PARKING BAY BIKE LANE LANE LANE BIKE LANE
7.50 5.00
1.50

CROWN
4.0
CONCRETE CURB & GUTTER
OPSD 600.070 (TYP.)

40mm ASPHALT SURFACE COURSE HL 3


3.50 40mm ASPHALT SECOND COURSE HL 8
1.0 0.70 45mm ASPHALT BINDER COURSE HL 8 HYDRANT 1.0
1.8 1.8
CONCRETE CONCRETE
SIDEWALK (TYP.) SIDEWALK (TYP.)
HYDRO VALVE
VAULT 5% MAX.
BOX 5% MAX.
2% 2% MIN. 2%
2% MIN.
2% 2%
0.3m (TYP.) CURB
0.7 STOP
3% 3%

NORTH OR EAST STREETLINE


1.80 MIN COVER
SOUTH OR WEST STREETLINE

TREE &
UTILITY PEDESTAL
150mm GRANULAR 'A'
380mm GRANULAR 'B'
(TYP.)
400mm
TRENCH)

TRENCH)
150mm SUBDRAIN
KS-346

KS-346
(JOINT

(JOINT
3.00
TREE, UTILITY PEDESTAL,
& STREET LIGHT POLE

SANITARY SEWER
2.50 1.00 1.00 2.50

WATERMAIN
STORM
SEWER
5.50

NOTES:
1. ALL DIMENSIONS IN METRES UNLESS NOTED.
2. ALL GRANULAR MATERIALS TO BE COMPACTED TO 100% STANDARD PROCTOR DENSITY.
3. ALL ASPHALT AND GRANULAR DEPTHS SPECIFIED ARE MINIMUM DEPTHS AND ARE
SUBJECT TO INCREASE BASED ON SOIL CONDITIONS.
4. BELL, HYDRO, COAXIAL, AND GASMAIN TO BE LOCATED IN COMMON TRENCH.
(SEE KS-346)
APPROVED DATE OF ISSUE

TOWNSHIP OF KING M.C. FEB. 2017

REVISION DRAWING No.

26.0m COLLECTOR ROADWAY


12.5m PAVEMENT WIDTH (BIKE LANES) DATE OF REVISION KS-210
MAR. 2017
1.5m CONC. S/W

R
=
18

m
.7

.0
5m

13
=
R

A = 34.110m
22.382m

7m
4.90
R=
20m A=1 R=1
4.25m

CATCHBASINS TO BE PLACED AT
BEGINNING OF BULB
1.5m CONC. S/W

1.5m CONC. S/W

0.91m 0.91m

5.75m 8.5m 5.75m

20m

NOTES:

1. MINIMUM GUTTER SLOPE TO BE 1.00%


2. DETAIL OF GRADING OF BULB AREAS OF CUL-DE-SACS TO BE SHOWN ON PROFILE
DRAWINGS.
3. CUL-DE-SAC DRAINAGE TO BE DIRECTED TOWARDS THE BEGINNING OF THE BULB.
4. ALL DIMENSIONS ARE IN METRES.

APPROVED DATE OF ISSUE

TOWNSHIP OF KING M.C. FEB. 1980

REVISION DRAWING No.

TYPICAL CUL-DE-SAC
FOR RESIDENTIAL STREETS
DATE OF REVISION KS-218
NOV. 2009
R= m
24.0
m 17.5
R=

46.0m
42.83
4m

R = 60.0m

R = 53.5m
R= m
24.0
m 17.5
R=

6.5m 10.0m 6.5m

23.0m
46.0m

SYMMETRICAL
71
5.5
mm

NOTES:
R=
45
R=

.0m

1. MINIMUM GUTTER SLOPE TO BE 1.00%


38
.5m

2. DETAIL OF GRADING OF BULB AREAS OF CUL-DE-SACS TO BE SHOWN ON


PROFILE DRAWINGS.
3. CUL-DE-SAC DRAINAGE TO BE DIRECTED TOWARDS THE BEGINNING OF THE
BULB.
4. ALL DIMENSIONS ARE IN METRES.

6.5m 10.0m 6.5m

23.0m

OFFSET

APPROVED DATE OF ISSUE

TOWNSHIP OF KING M.C. FEB. 1980

REVISION DRAWING No.

TYPICAL CUL-DE-SAC
FOR INDUSTRIAL STREETS
DATE OF REVISION KS-219
NOV. 2009
TURNING CIRCLE PAVEMENT DESIGN: 32mm HL3 ASPHALT SURFACE COURSE
50mm HL8 ASPHALT BINDER COURSE
150mm GRANULAR 'A'
300mm GRANULAR 'B'

ROAD
EASEMENT

FINAL REGISTERED 0.3m RESERVE


LOT

STREET LINE

m
0.0

m
=1

.2
12
R

=
R

32.0m
CURB & GUTTER

R
=1
0.0
m

STREET LINE

FINAL REGISTERED
LOT

32.0m
PROPERTY LINE

NOTES:

1. TEMPORARY TURNING CIRCLES SHALL BE USED ONLY FOR PHASING OF RESIDENTIAL


SUBDIVISIONS, SUBJECT TO THE TOWNSHIP ENGINEER'S APPROVAL.
2. ALL DIMENSIONS ARE IN MILLIMETRES OR METRES.
3. THE SUBDIVIDER WILL DEPOSIT WITH THE TOWNSHIP AN AMOUNT WHICH THE TOWNSHIP
ENGINEER CALCULATES TO BE THE COST OF REMOVING THE TURNING CIRCLE AND
CONSTRUCTING THE STANDARD ROAD FROM THE START OF THE TURNING CIRCLE TO THE
LIMIT OF THE SUBDIVISION.

APPROVED DATE OF ISSUE

TOWNSHIP OF KING M.C. FEB. 1980

REVISION DRAWING No.

TEMPORARY TURNING CIRCLE


FOR RESIDENTIAL STREETS
DATE OF REVISION KS-220
NOV. 2009
35.0

STREET LINE

R=16

1.5
CURB

1.5
CL OF R.O.W
WIDENING DEFLECTION

R=30

R1

S
WIDENING DEFLECTION

S
CL OF R.O.W
35.0

R=30

S
ROAD TYPE RI
(MIN.)

LOCAL 5 10
COLLECTOR OR INDUSTRIAL 8 12

NOTES:
1. CHAINAGE TO BE CALCULATED USING A CENTRELINE RADIUS OF 15m.
2. GUTTER GRADES TO BE DETAILED ON THE ENGINEERING DRAWINGS.
MINIMUM GRADE ALONG GUTTER TO BE 0.50%.
3. THE LOCATION OF ANY SIDEWALK IS TO BE DETAILED IN THE ENGINEERING DRAWINGS.
4. ALL CURB RADII ARE TO FACE OF CURBS.
5. BOULEVARD WIDTHS ARE TO BE MAINTAINED.
6. ALL DIMENSIONS ARE IN MILLIMETRES OR METRES.

APPROVED DATE OF ISSUE

TOWNSHIP OF KING M.C. FEB. 1980

REVISION DRAWING No.

TYPICAL ROAD BEND


DATE OF REVISION KS-224
MAR. 2016
STREET LINE

0.9m
1.80m 1.80m
50mm

CONTRACTION
JOINT

1.50m
A A

EXPANSION JOINT EXPANSION JOINT

PLAN VIEW

130mm NORMAL, 180mm AT DRIVEWAYS

LONGITUDINAL SECTION

130mm EXPANSION JOINT

130mm OR
180mm
15mm

SECTION B-B
EXPANSION JOINT DETAIL

130mm
40mm

130mm OR
180mm
5mm

SECTION A-A
CONTRACTION JOINT DETAIL

1.50m AS SPECIFIED

6mm
6mm
SOD ROUND CURB
ROUND SOD
2% 2% MIN.
5% MAX.

90mm

SEE NOTE 2 MIN. 100mm GRANULAR 'A' COMPACTED


TO 100% STANDARD PROCTOR DENSITY

COMPACTED SUBGRADE TO 95% S.P.D.

BOULEVARD SECTION
NOTES:

1. CONCRETE TO BE 30 MPa; 5-7% AIR ENTRAINED WITH A 20mm MAX. AGGREGATE SIZE.
2. FOR COMMERCIAL, INDUSTRIAL, AND APARTMENT DRIVEWAYS, SIDEWALK TO
BE REINFORCED WITH 152 x 152 MW 18.7 x MW 18.7 METRIC WELDED WIRE.
3. EXPANSION JOINTS ARE ALSO REQUIRED WHERE THE SIDEWALK ABUTS OTHER CONCRETE STRUCTURE, WALKS,
CURBS, UTILITY POLES, HYDRANTS, MANHOLES, AND AT CERTAIN LOCATIONS AT DISCRETION OF THE ENGINEER.
4. CONTRACTION JOINTS TO BE FORMED AFTER THE CONCRETE HAS RECEIVED ITS INITIAL SET.
5. ALL DIMENSIONS ARE IN MILLIMETRES OR METRES

APPROVED DATE OF ISSUE

TOWNSHIP OF KING M.C. FEB. 1980

REVISION DRAWING No.

CONCRETE SIDEWALK DATE OF REVISION KS-231


MAY 2014
760mm

710mm

SIDE VIEW

305mm
610mm

275mm

170mm

TOP VIEW 150mm


305mm

0.60m MIN.
SPLASH PAD

3% MAX.
185mm

150mm

305mm BEDDING MATERIAL


150mm 305mm

TOP VIEW

NOTES:
1. MINIMUM CONCRETE STRENGTH SHALL BE 20 MPa.
2. BEDDING MATERIAL SHALL BE 19mm CLEAR STONE OR EQUIVALENT.
3. SPLASH PADS TO BE USED TO DIRECT DRAINAGE FROM ALL RAINWATER DOWNSPOUTS.
4. ALL DIMENSIONS ARE IN MILLIMETRES OR METRES UNLESS OTHERWISE SPECIFIED.

APPROVED DATE OF ISSUE

TOWNSHIP OF KING M.C. FEB. 1980

REVISION DRAWING No.

PRECAST CONCRETE
SPLASH PAD DETAIL DATE OF REVISION KS-302
NOV. 2009
100 x 100 mm POSTS
AT 2.4m c/c 50 x 100mm
TOP PLATE
A

25 x 150 x 1800mm
FACER BOARDS
(STAGGERED)

50mm
GAP
50 x 100
1800mm

1350mm
300mm

A SECTION A-A
50mm

900mm
1200mm

FILL EXCAVATION WITH


20 MPa CONCRETE

50mm
MAX.
TOP VIEW
SECTION
300mm

NOTES:

1. USE CONSTRUCTION GRADE CEDAR, CALIFORNIA RED WOOD OR PRESSURE TREATED LUMBER
ONLY. DO NOT USE SPRUCE OR HEMLOCK.
2. ALL FASTENERS AND HANGERS TO BE GALVANIZED.
3. ALL DIMENSIONS ARE IN MILLIMETRES OR METRES.

APPROVED DATE OF ISSUE

TOWNSHIP OF KING M.C. JUNE. 1993

REVISION DRAWING No.

WOOD PRIVACY FENCE DATE OF REVISION KS-313


NOV. 2015
m
10m 10mm

20mm 10mm
5mm 10mm

20mm
60mm

60mm
15mm 5mm

PIN DETAIL
1.5m (TYP.)

HINGE AND PIN COMPONENTS TO BE

P.)
500mm
GALVANIZED STEEL AND WELDED

(T Y
NOTE:

m
ONTO SLEEVE PLATE AND POST

1.2
MAXIMUM LONGITUDINAL
RESPECTIVELY. PADLOCK TO BE SLOPE TO BE 8%
PROVIDED BY TOWNSHIP.

GALVANIZED STEEL
BOLLARD REMOVABLE
(SEE DETAIL 'A')

SAWCUT
150mm HIGH CONCRETE
JOINT (TYP.)

m
CURB (TYP.)

1. 5
2%
2% TAPER ENDS OF CURB
100 (TYP.)
mm

HINGE

m
40m

3.0m
CONCRETE SIDE
DETAIL 'A' (WHEN SPECIFI WALK
ED ON ENGINEE
RING DRAWIN
G)

DRESSED CURB AS PER


STANDARD DRAWING KS-225

100mm DIAMETER GALVANIZED STEEL POST WITH GALVANIZED


TOP. WHERE GRADES EXCEED 8%, A MAZE SHALL BE DESIGNED
AND CONSTRUCTED SUBJECT TO THE TOWNSHIP ENGINEERS
APPROVAL
CROSS SECTION

100mm 3.0m
1.5m CHAINLINK FENCE
50mm
INSTALLED AS PER
STANDARD DWG. KS-311 150mm 150mm
150mm
R = 50mm

1.20m 1.20m
CENTRELINE OF SWALE

CENTRELINE OF SWALE
450mm

LOT LINE

LOT LINE
(TYPICAL)

CONCRETE SIDEWALK (TYPICAL)


SEE
DETAIL 'A'

CONCRETE CURB
2% 2%
150mm 3 3
1 1

CONCRETE CURB
DETAIL (TYPICAL) 100mm TOP SOIL
1.0m

AND SOD (TYP.)

150mm CONCRETE CURB


SEE DETAIL (TYP.)

250mm 250mm
NOTES: SONO TUBE
GALVANIZED SLEEVE
1. ALL DIMENSIONS ARE IN MILLIMIETRES OR METRES.
2. SECURITY LIGHTING OF WALKWAYS TO BE PROVIDED. DESIGN OF LIGHTING
WILL BE SUBJECT TO APPROVAL BY THE TOWNSHIP OF KING.
3. ALL CONCRETE WORK TO CONFORM TO REQUIREMENT OF OPSD-1350. CLASS OF
CONCRETE: 25MPa, 5-7% AIR ENTRAINMENT, 20mm MAXIMUM AGGREGATE SIZE.
4. MAXIMUM SAW CUT JOINT SPACING TO BE 4.5m.
5. CONCRETE POST FOOTINGS TO BE SEPARATE FROM CURB.

APPROVED DATE OF ISSUE

TOWNSHIP OF KING M.C. JUNE. 1993

REVISION DRAWING No.

PEDESTRIAN WALKWAY
IN URBAN SETTING DATE OF REVISION KS-320
NOV. 2009
STREET SIGNS

0.5 STOP BAR


0.1 CROSS WALK

SIDEWALK SIDEWALK
REGULATORY SIGN
(Ra-1 STOP)

2.0
0.6MIN.

CL 0.6 - 2.0
1.5

2.5
15.0

1.0 REGULATORY SIGN


(Ra-1 STOP)

1.0
SIDEWALK

NO EXIT SIGN 1.0


(Wa-31)
STREETLINE

STREETLINE

INSTALLATION DETAIL
CURB

CURB

DEAD END

LOCATION PLAN

NOTES:

1. REGULATORY/WARNING SIGNS AS PER OHTA REG. 615/616 OR AMENDMENTS THEREOF.


2. STOP SIGNS (Ra-1) POSTS SHALL BE 75mm x 3.66m ALUMINUM COMPLETE WITH TOP CAP.
3. STOP SIGNS SHALL BE BANDED TO THE POST WITH MINIMUM 12.7mm x .76mm STAINLESS STEEL BANDING AND FLARED
LEG STAINLESS STEEL BRACKETS (BANDRIT BRACKETS OR EQUIVALENT).
4. ALL OTHER REGULATORY/WARNING SIGNS SHALL BE MOUNTED ON 3.66M 80,000psi U-FLANGE POSTS WHICH HAVE
THE TOP 1200mm PUNCHED ON 50mm CENTRES WITH 11mm HOLES.
5. ALL REGULATORY SIGNS SHALL CONFORM WITH THE CURRENT VERSION OF THE ONTARIO TRAFFIC MANUAL (O.T.M).
6. ALL WARNING SIGNS AND INSTALLATIONS SHALL CONFORM WITH THE CURRENT VERSION OF THE O.T.M
7. ALL WARNING AND REGULATORY SIGNS SHALL BE MOUNTED A MINIMUM OF 2.0M ABOVE FINISHED GROUND ELEVATION.
8. ALL REGULATORY AND WARNING SIGN BLANKS SHALL BE ALUMINUM AND BE HIGH DENSITY REFLECTORIZED SURFACES.

ALL DIMENSIONS ARE EXPRESSED IN METRES (m) UNLESS OTHERWISE NOTES.


APPROVED DATE OF ISSUE

TOWNSHIP OF KING M.C. FEB. 1980

REVISION DRAWING No.

TRAFFIC SIGN DETAILS


& PAVEMENT MARKINGS DATE OF REVISION KS-331
MAR. 2016
WARNING

NOTE: CIRCLE AND STRIKETHROUGH TO BE RED.

ALL DIMENSIONS ARE EXPRESSED IN METRES (m) UNLESS OTHERWISE NOTES.


APPROVED DATE OF ISSUE

TOWNSHIP OF KING M.C. MAY 2016

REVISION DRAWING No.

STORMWATER MANAGEMENT FACILITY


WARNING SIGN DATE OF REVISION KS-335
CL
DRIVEWAY

100mm TOPSOIL
AND SOD (TYP.)
D/W WIDTH (VAR.)

3 3
1 1
300mm MIN. PIPE COVER (NOTE 3)

DIRECTION DITCH
OF FLOW INVERT

CORRUGATED STEEL RIVETED PIPE AT MINIMUM 1.0% GRADE

NOTES:

1. BARREL LENGTH TO BE D/W WITH PLUS 5.0m. MINIMUM LENGTH SHALL BE 8.5m.
2. MINIMUM DIAMETER SHALL BE 400mm AND THE MINIMUM METAL THICKNESS
SHALL BE 1.6mm.
3. THE MINIMUM DEPTH OF COVER SHALL BE 300mm OR DIAMETER OF C.S.P.
CULVERT DIVIDED BY 6.0, WHICHEVER IS GREATER.
4. BEDDING FOR C.S.P. CULVERTS SHALL BE CONSTRUCTED IN ACCORDANCE WITH O.P.S.D.
802.04. GRANULAR 'A' BACKFILL SHALL BE PLACED AND COMPACTED TO 100% STANDARD
PROCTOR DENSITY.
5. CORRUGATED STEEL PRODUCTS SHALL CONFORM WITH O.P.S.S. 1801 AND THE
REQUIREMENTS OF CAN 3-G401.
6. HELICAL C.S.P. CULVERTS ARE NOT APPROVED FOR USE IN THE TOWNSHIP OF KING.
7. ALL NEW DRIVEWAYS ARE TO BE STAKED AS TO THEIR PROPOSED LOCATION AND APPORVED
BY THE TOWNSHIP.
8. HOMEOWNERS ARE RESPONSIBLE TO LOCATE ALL UNDERGROUND SERVICE AND UTILITY
PLANTS IN THE AREA OF THE DRIVEWAY ENTRANCES, PRIOR TO INSTALLATION.

APPROVED DATE OF ISSUE

TOWNSHIP OF KING M.C. JAN. 1990

REVISION DRAWING No.

STANDARD DRIVEWAY CULVERT DATE OF REVISION KS-340


PROPERTY
LINE

EXPANSION JOINT

300mm
DEPRESSED CURB

6.60m MAX. DOUBLE DRIVEWAY

6.0m MAX. DOUBLE DRIVEWAY


3.60m MIN. SINGLE DRIVEWAY

3.0m MIN. SINGLE DRIVEWAY

CONCRETE
SIDEWALK
CONTRACTION JOINT

EXPANSION JOINT
300mm

EXPANSION JOINT

PLAN VIEW

PROPERTY
LINE

1% MIN.
8% MAX.
2% MIN.
5% MAX.
8%

LIMIT OF
APPROACH PAVING

50mm MIN. ASPHALT HL3

155mm MIN. GRANULAR 'A'


OR 100mm OF 20mm SIZED C.R. LIMESTONE
TYPICAL SECTION
COMPACTED SUBGRADE ON STREETS WITHOUT SIDEWALK

CONCRETE
SIDEWALK
2% MIN. 1% MIN.
5% MAX. 8% MAX.
2% MIN. 2%
8% MAX.
180mm

WIRE MESH RENIFORCING

50mm MIN. ASPHALT HL3


PROPERTY
LIMIT OF LINE
155mm MIN. GRANULAR 'A'
OR 100mm OF 20mm SIZED C.R. LIMESTONE APPROACH PAVING

COMPACTED SUBGRADE

TYPICAL SECTION
ON STREETS WITH SIDEWALK

NOTES:

1. ALL DIMENSIONS ARE IN MILLIMETRES OR METRES.


2. FIRE HYDRANTS, TRANSFORMERS, AND UTILITY PEDESTALS TO BE LOCATED A
MINIMUM OF 3.0m FROM ANY DRIVEWAY.
3. STREETLIGHTS TO BE LOCATED A MINIMUM OF 1.5m FROM ANY DRIVEWAY.

APPROVED DATE OF ISSUE

TOWNSHIP OF KING M.C. FEB. 1980

REVISION DRAWING No.

DRIVEWAY APPROACH PAVING


FOR RESIDENTIAL DRIVEWAYS DATE OF REVISION KS-341
MAY 2016
EXPANSION JOINT EXPANSION JOINT

1.2m
150mm HIGH CONCRETE BARRIER CURB

CONTRACTION
JOINT

EXPANSION JOINT

SIDEWALK
DEPRESSED CURB 11.4m MAXIMUM NOTE:
AN EXISTING SIDEWALK OF LESS THAN
180mm THICKNESS ACROSS THE

9.0m MAX.
PROPOSED DRIVEWAY IS TO BE EXPANSION JOINT PROPERTY
REMOVED AND REPLACED WITH A LINE
180mm THICK SIDEWALK. NEW
SIDEWALK TO BE REINFORCED WITH

CONCRETE
152 x 152 MW 18.7 x MW 18.7 WELDED
WIRE FABRIC.

EXPANSION JOINT

CONTRACTION
JOINT

150mm HIGH CONCRETE BARRIER CURB


1.2m

EXPANSION JOINT
EXPANSION JOINT

PLAN VIEW

COMMERCIAL, LIGHT INDUSTRIAL, APARTMENTS:

45mm ASPHALT BASE COURSE HL3


50mm ASPHALT BASE COURSE HL8

150mm GRANULAR 'A'


OR 200mm CRUSHER RUN LIMESTONE
225mm GRANULAR 'B'

LIMIT OF
APPROACH PAVING

2% MIN.
6% MAX.

PROPERTY
LINE
40mm ASPHALT SURFACE COURSE HL3
TYPICAL SECTION 75mm ASPHALT BASE COURSE HL8
ON STREETS WITHOUT SIDEWALK 150mm GRANULAR 'A'
OR 235mm CRUSHER RUN LIMESTONE
300mm GRANULAR 'B'

HEAVY INDUSTRIAL

CONCRETE
LIMIT OF SIDEWALK
APPROACH PAVING 2% MIN.
5% MAX.
2% MIN. 2%
6% MAX.
180mm

RENIFORCING
WIRE MESH

PROPERTY
HEAVY INDUSTRIAL: LINE
40mm ASPHALT SURFACE COURSE HL3

TYPICAL SECTION 75mm ASPHALT BASE COURSE HL8


150mm GRANULAR 'A'
ON STREETS WITH SIDEWALK 235mm CRUSHER RUN LIMESTONE OR
300mm GRANULAR 'B'

COMMERCIAL, LIGHT INDUSTRIAL, APARTMENTS


SEE DRIVEWAY DESIGN ABOVE

NOTES:

1. ALL DIMENSIONS ARE IN MILLIMETRES OR METRES.

APPROVED DATE OF ISSUE

TOWNSHIP OF KING M.C. FEB. 1980

REVISION DRAWING No.

DRIVEWAY APPROACH PAVING FOR


COMMERCIAL, INDUSTRIAL, & APARTMENTS DATE OF REVISION KS-342
NOV. 2015
5.75

1.00 1.50 1.70 1.50


0.50

S/W

CONDUIT FOR
CL BROADBAND
TRANSFORMER, 300mm MIN.
PEDESTAL,
CURB
OR VAULT
2%
MIN.

0.60 0.40 NATIVE BACKFILL


CAUTION TAPE 0.90
LIGHTPOLE

0.30 MIN.
1.20 MIN.

LIGHTING CONDUITS GAS MAIN (LOC.1)

GAS MAIN (LOC. 2)


COMMUNICATION 0.30 MIN.
CABLES / FIBRE OPTIC
0.30 (TYP)
CLEAN MASONRY SAND

PRIMARY & SECONDARY HYDRO AS


PER HYDRO ONE REQUIREMENTS
UNDISTURBED SOIL OR WELL 1.00 0.60
COMPACTED NATIVE BACKFILL (TYP)
2.50

NOTES
*DENOTES 26m R.O.W. (REFER TO WS-103 & WS-104 FOR DIMENSIONS AND ROAD DETAILS).

1. ALL DIMENSIONS ARE IN METRES UNLESS NOTED OTHERWISE.

2. ALL SEPARATIONS TO BE AS PER OPSD 2101.01.

3. STREETLIGHT WIRE DUCT MAY BE INSTALLED AT A REDUCED DEPTH UP TO A MINIMUM DEPTH OF 600mm.

4. GAS MAIN TO BE INSTALLED IN LOC. 1 SUBJECT TO AGREEMENT AND APPROVAL BY THE TOWNSHIP AND GAS UTILITY.

5. CONDUIT FOR FUTURE BROADBAND SHALL BE 75mm DIA. RIGID PVC WITH A WALL THICKNESS OF 5.5mm.

APPROVED DATE OF ISSUE

TOWNSHIP OF KING M.C. DEC 2015

REVISION DRAWING No.

DATE OF REVISION KS-346


PROPERTY ELEVATION AT REAR LOT CORNER

9. 50

0. 90
REAR LOT DRAINAGE SWALE

27 9.

28 9.
10

70
27

27
(IF APPLICABLE)
N
SWALE

EXISTING ELEVATION AT REAR LOT CORNER

LOT NUMBER

221 HOUSE NUMBER

48
DIRECTION OF REAR LOT DRAINAGE

280.00 280.00

SPECIFIED REAR HOUSE GRADE


(IF APPLICABLE)

BREAK POINT ELEVATION


1. 90

1. 90
28 3.

28 3.
00

00
28

28
281.00

EXISTING CONTOUR FOUNDATION


ELEVATION WALL

SPECIFIED LOT GRADE

288.00 288.00

INDICATE APPROPRIATE D/W


GRADING STANDARD GRADE
(R/S, B/S, W/O)

PROPERTY ELEVATION AT STREET


20 0

60 0
8

2
2.

3.
28

28
3.

3.
28

28
CONCRETE SIDEWALK

EXISTING ELEVATION AT STREET

PROPOSED CENTRELINE ROAD ELEVATIONS


AT EVEN 20.00m STATIONS AND ALL LOT CORNERS

80
00
0

60

0.
.8

9.

0.
8

28
27
27

28

CONCRETE SIDEWALK

NOTES:

1. ALL CATCHBASINS LOCATIONS TO BE SHOWN ON GRADING PLAN. 6. PROVIDE MAIN FLOOR AND BASEMENT ELEVATIONS.
2. ALL EASEMENTS MUST BE SHOWN ON GRADING PLAN. 7. SPECIFY PROPOSED GRADES ON ALL SWALES.
3. THIS LEGEND MUST APPEAR ON ALL GRADING PLANS. 8. IDENTIFY PROPOSED LOCATION AND DIMENSIONS OF PRIMARY AND
4. ALL DIMENSIONS ARE IN MILLIMETRES OR METRES UNLESS OTHERWISE RESERVE SEPTIC TILE BED AREAS AND APPROVAL CERTIFICATE OF
YORK REGION HEALTH UNIT.
SPECIFIED.
5. PROVIDE LOT GRADING CERTIFICATE BY DEVELOPER'S ENGINEER IN 9. PROVIDE REGISTERED PLAN NUMBER ON GRADING PLAN.
ACCORDANCE WITH SUBDIVISION AGREEMENT REQUIREMENTS. 10. REFER TO SECTION F FOR ALL OTHER REQUIREMENTS.

APPROVED DATE OF ISSUE

TOWNSHIP OF KING M.C. FEB. 1980

REVISION DRAWING No.

TYPICAL LEGEND FOR


LOT GRADING PLAN
DATE OF REVISION KS-400
NOV. 2015
STREETLINE

STREETLINE
CL FLOWS TO BE CARRIED AROUND
HOUSE IN DEFINED SWALES LOCATED
BESIDE LOT LINES.

2% MIN. SWALE GRADE BEHIND


APPROX. LOCATION OF FLOW
DIVISION POINT VARIES WITH
ROAD GRADE TO SUIT

PLAN

SPECIFIED
LOT GRADE

FRONT LOT ELEVATION


OF CORNER
300mm MAX.
150mm MIN.

F.F X.
3:1 MA
6% MAX.
2.0% MIN.
150mm
MIN.

2% MIN. SIDE
YARD SWALE

REAR LOT LINE


SETBACK HOUSE DEPTH 3.0m 6.0m
MIN. MIN.

ELEVATION

NOTES:
1. SPECIFIED LOT GRADE SHALL BE MIN. 300mm ABOVE THE HIGHEST FRONT
LOT CORNER.
2. DRIVEWAYS ARE NOT TO BE USED AS AN OUTLET FOR ANY SIDE YARD
SWALE.
3. ALL DIMENSIONS ARE IN MILLIMETRES OR METRES UNLESS OTHERWISE
SPECIFIED.

APPROVED DATE OF ISSUE

TOWNSHIP OF KING M.C. FEB. 1980

REVISION DRAWING No.

FRONT LOT DRAINAGE DATE OF REVISION KS-401


NOV. 2009
STREETLINE

STREETLINE
CL

DRAINAGE SWALE.
IF NOTED, MIN.
GRADE TO BE 2.0%

PLAN

SPECIFIED
LOT GRADE

REAR LOT LINE


FRONT LOT ELEVATION
OF CORNER
300mm MAX.
150mm MIN.

F.F
2.0% MIN.
5.0% MAX
.
150mm
MIN.

3:1 H
2% MIN. SIDE MA
YARD SWALE X.

3:1
SETBACK HOUSE DEPTH 6.0m 1.50m MA
MIN. MIN. X.

NOTE:
IF ATTACHED GARAGE IS CONSTRUCTED,
THEN REAR YARD SLOPE MAY COMMENCE
ELEVATION AT REAR WALL OF GARAGE

NOTES:
1. SPECIFIED LOT GRADE SHALL BE MIN. 300mm ABOVE THE HIGHEST FRONT
LOT CORNER.
2. DRIVEWAYS ARE NOT TO BE USED AS AN OUTLET FOR ANY SIDE YARD
SWALE.
3. 'H' DIMENSION TO BE 1.80m MAX. UNLESS UNDISTURBED EXISTING SLOPE.
TERRACE CAN BE ELIMINATED ON SLOPES OF 4:1 OR LESS.
4. ALL DIMENSIONS ARE IN MILLIMETRES OR METRES UNLESS OTHERWISE
SPECIFIED.

APPROVED DATE OF ISSUE

TOWNSHIP OF KING M.C. FEB. 1980

REVISION DRAWING No.

REAR LOT DRAINAGE DATE OF REVISION KS-402


NOV. 2009
STREETLINE

STREETLINE
CL

DRAINAGE SWALE.
IF NOTED, MIN.
GRADE TO BE 2.0%

PLAN

SPECIFIED
LOT GRADE

REAR LOT LINE


SPECIFIED REAR HOUSE GRADE
FRONT LOT ELEVATION
OF CORNER
2.10m FOR WALKOUT (MAX.)
1.20 FOR BACKSPLIT (MAX.)
300mm MAX.
150mm MIN.

F.F

2.0% MIN.
150mm MIN.
5.0% MAX
2% MIN. SIDE .
YARD SWALE
3:1 H
MA
X.
SETBACK HOUSE DEPTH 6.0m
MIN. 3:1
1.50m MA
MIN. X.

ELEVATION

NOTES:
1. SPECIFIED LOT GRADE SHALL BE MIN. 300mm ABOVE THE HIGHEST FRONT
LOT CORNER.
2. 'H' DIMENSION TO BE 1.80m MAX. UNLESS UNDISTURBED EXISTING SLOPE.
TERRACE CAN BE ELIMINATED ON SLOPES OF 4:1 OR LESS.
3. REAR HOUSE GRADE MUST ALSO BE SPECIFIED ON LOT GRADING PLANS
WHEN THIS HOUSE TYPE IS PROPOSED.
4. ALL DIMENSIONS ARE IN MILLIMETRES OR METRES UNLESS OTHERWISE
SPECIFIED.

APPROVED DATE OF ISSUE

TOWNSHIP OF KING M.C. FEB. 1980

REVISION DRAWING No.

REAR LOT DRAINAGE FOR


WALKOUT OR BACKSPLIT OUT DATE OF REVISION KS-403
NOV. 2009
STREETLINE

STREETLINE
CL

PLAN

SPECIFIED
LOT GRADE
2% MIN. SIDE YARD SWALE

SPECIFIED REAR HOUSE GRADE

FRONT LOT ELEVATION


OF CORNER

AX.
3:1 M
F.F 150mm MIN.
300mm MAX.
150mm MIN.

6.0% MAX.
2.0% MIN.
.
AX

1.80m MAX.
M

REAR LOT LINE


1
3:

SETBACK HOUSE DEPTH 3.0m 6.0m


MIN. MIN.

ELEVATION

NOTES:
1. SPECIFIED LOT GRADE SHALL BE MIN. 300mm ABOVE THE HIGHEST FRONT
LOT CORNER.
2. DRIVEWAYS ARE NOT TO BE USED AS AN OUTLET FOR ANY SIDE YARD
SWALE.
3. REAR HOUSE GRADE MUST ALSO BE SPECIFIED ON LOT GRADING PLANS
WHEN THIS HOUSE TYPE IS PROPOSED.
4. ALL DIMENSIONS ARE IN MILLIMETRES OR METRES UNLESS OTHERWISE
SPECIFIED.

APPROVED DATE OF ISSUE

TOWNSHIP OF KING M.C. FEB. 1980

REVISION DRAWING No.

FRONT LOT DRAINAGE


FOR FRONT SPLIT HOUSE DATE OF REVISION KS-404
NOV. 2009
ACCEPTED TO BE IN GENERAL CONFORMANCE WITH THE
TOWNSHIP OF KING STANDARDS APPROVED
THIS ACCEPTANCE IS NOT TO BE CONSTRUED
AS VERIFICATION OF ENGINEERING CONTENT
Engineering Department

TOWNSHIP ENGINEER
Region of York

DATE: Date:

REVISIONS

No. Revision Date By Approved

CORPORATION OF THE TOWNSHIP OF KING

SUBDIVISION NAME

STREET OR EASEMENT

LIMITS

CONSULTANTS NAME,

ADDRESS AND TELEPHONE No.

Project No:
Scale

Drawing No:
Drawn By:

ENGINEERS
STAMP Designed By:

Checked By:

Date:

NOTES:
1. THE ABOVE TITLE BLOCK MUST APPEAR ON CONTRACT DRAWINGS.
2. "APPROVED" BLOCKS MUST APPEAR ON DRAWINGS IN A POSITION WHICH
WILL NOT RESTRICT REVISION TABLE.

APPROVED DATE OF ISSUE

TOWNSHIP OF KING M.C. FEB. 1980

REVISION DRAWING No.

DRAWING TITLE BLOCK DATE OF REVISION KS-500


NOV. 2009
1.5m
(5.0')

FINIAL
LED FIXTURE
(BLACK)

0.15m
(6")
SCROLL ARM
(BLACK)

OCTAGONAL BLACK CONCRETE POLE


(ACRYLIC COATED)
7.60m
(25.0')
(30.0')
9.1m

NAME PLATE
(12.0")
0.3m

HAND HOLE & COVER


PLATE FACING SIDEWALK
1.2m
(4.0')

GRADE
1.65m
(5.5')

(18.0")
0.45m

NATIVE
BACKFILL

2-50mm x 100mm APERTURES


(5.0')
1.5m

LIMESTONE SCREENINGS COMPACTED TO


1.05m
(3.5')

100% PROCTOR DENSITY

75mm 75mm

NOTES:
1. DIMENSIONS ARE TYPICAL AND SUBJECT TO ADJUSTMENT TO
SUIT SPECIAL LIGHTING DESIGN.

2. SEE SECTION J FOR DETAILS AND SPECIFICATIONS

APPROVED DATE OF ISSUE

TOWNSHIP OF KING M.C. AUG. 1981

REVISION DRAWING No.

TYPICAL POLE & LUMINAIRE


(DECORATIVE) DATE OF REVISION KS-701
FEB. 2017
VERTICAL TRENCHING ACROSS PAVED AREAS
AND WHERE ELSE REQUIRED

GRADE

SEE NOTE 5 SEE NOTE 5


1 3 1 3
BACKFILL

1.80m MINIMUM
3 3 ZONE

300mm
MIN.

1200mm MAXIMUM
E

SEE NOTE 5
BEDDING
ZONE

Bc
100mm
MIN.
d
CLASS B
Lf = 1.9 CLASS D
(FOR CONCRETE PRESSURE PIPE WATERMAINS)
Bd

Bd
300

SAND BACKFILL COMPACTED


TO 98% STANDARD

300
PROCTOR DENSITY
(S.P.D.)

Bc
0.5 Bc

Bc
d (100mm MIN.)
CLEAN DRY EARTH, FREE FROM
LUMPS, COMPACTED TO 98%
DRY TRENCH S.P.D.
20mm CRUSHER RUN LIMESTONE
COMPACTED TO 98% S.P.D.
WET TRENCH CLASS F
HL8 BLEND OF CRUSHED Bd (FOR P.V.C. WATERMAINS ONLY)
CLEAR STONE
SAND BACKFILL COMPACTED
TO 98% PROCTOR DENSITY
300

LEGEND
TRACE WIRE-No.12 GAUGE
STANDARD C.S.A. TYPE T.W.H. TAPED Bc = OUTSIDE DIAMETER
TO THE WATERMAIN WITH Bd = WIDTH OF TRENCH
FIBERGLASS TAPE = Bc + 0.60m WITH MINIMUM 0.90m
= Bc + WIDTH OF SHORING + 0.60m
Bc
0.75 Bc

d = DEPTH OF BEDDING MATERIAL BELOW PIPE


20mm CRUSHER RUN LIMESTONE H = BACKFILL COVER ABOVE TOP OF PIPE
COMPACTED TO 98% PROCTOR DENSITY
ALL VALVES AND FITTINGS TO BE
COMPLETELY BACKFILLED WITH
100

20mm CRUSHER RUN LIMESTONE

PVC PRESSURE PIPE STANDARD


NOTES: DIMENSION RATIO NOT TO EXCEED SDR 18
1. ALL DIMENSIONS ARE IN MILLIMETRES OR METRES. 3. CONNECTORS USED FOR SPLICING TRACER WIRES SHALL BE WING
NUT TYPE WITH NYLON SHELL AND NON-CORROSIVE STEEL WIRE
2. ALL BACKFILL MATERIAL TO BE COMPACTED TO 95% STANDARD SPRING.
PROCTOR DENSITY. 4. TRENCH DIMENSIONS AND SLOPING OF WALLS TO BE UNDERTAKEN IN
ACCORDANCE WITH REQUIREMENTS OF THE OCCUPATIONAL HEALTH
AND SAFETY ACT, AS AMENDED.

APPROVED DATE OF ISSUE

TOWNSHIP OF KING M.C. FEB. 1980

REVISION DRAWING No.

WATERMAIN TRENCH
AND BEDDING DETAILS DATE OF REVISION KS-801
NOV. 2015
20 MPa CONCRETE HIGHWATER LINE

SHORELINE

WATERCOURSE WATERCOURSE

WATERMAIN

SHORING

PLAN

0.90m MINIMUM
TRENCH WIDTH

WATER LEVEL WATER LEVEL

BOTTOM OF
MINIMUM COVER

WATERCOURSE
1.80m

HL8 BLEND CRUSHED CLEAR STONE


225 COMPACTED TO 98% PROCTOR
MINMUM DENSITY
300
MINMUM
20 MPa CONCRETE SLAB

WATERMAIN

HL8 BLEND CRUSHED CLEAR STONE


COMPACTED TO 98% PROCTOR DENSITY
225
MINMUM

SHORING

ELEVATION

NOTES:
1. ALL SLOPING MUST BE CUT OFF AT CREEK BED WHEN CONSTRUCTION
IS COMPLETED.
2. VALVES WILL BE PROVIDED AT BOTH ENDS OF WATER CROSSING
ABOVE THE HIGHWATER LINE AT THE DISCRETION OF THE TOWNSHIP
ENGINEER.
3. ALL DIMENSIONS ARE IN MILLIMETRES OR METRES UNLESS
OTHERWISE SPECIFIED.

APPROVED DATE OF ISSUE

TOWNSHIP OF KING M.C. FEB. 1980

REVISION DRAWING No.

WATERMAIN TRENCH DETAIL


UNDER WATERCOURSE DATE OF REVISION KS-802
NOV. 2009
50mm CURB STOP & DRAIN
MUELLER No. H15182 OR AN
APPROVED EQUIVALENT
JOINT TO BE MECHANICALLY GLAND RING
RESTRAINED (REFER TO
NOTE 1 FOR METHOD OF
50mm TAPPED TEE
RESTRAINING JOINTS)
PIPE SCHEDULE 40
MINIMUM 900

300
MIN.
150
MAX.
600

20mm CRUSHER RUN LIMESTONE


WIDTH OF TRENCH COMPACTED TO 95% PROCTOR DENSITY
AND THRUST BLOCK

PLAN

TABLE 1

MIN. RESTRAINED
PIPE SIZE
LENGTH (m)

MAX
50
150 4.6 50mm BRASS CAP OR
GALVANIZED IRON
(SEE NOTE 3)
200 5.5
CAN. VAL SERIES 161-2
HEAVY SERVICE BOX VALVE BOX
250 7.0
OR APPROVED EQUAL

300 8.3
1800 MIN.

IRON PIPE SCHEDULE 40

50mm CURB STOP & DRAIN


MUELLER No. H15182 OR AN
APPROVED EQUIVALENT

300 MIN.

DRAIN PORT

WATERMAIN
20mm CRUSHER
RUN LIMESTONE
250mm CONCRETE BLOCK

ELEVATION

NOTES:
1. JOINTS ON PVC MAIN ARE TO BE RESTRAINED USING UNI-FLANGE 3. THREADS ON CAP TO BE GREASED AND CAP TO BE INSTALLED
SERIES 1300 RESTRAINER (OR APPROVED EQUAL). LOOSELY.
4. BLOW-OFF AND TAPPED TEE TO BE COMPLETELY BACKFILLED WITH
2. ALL JOINTS ENCOUNTERED WITHIN THE SPECIFIED RESTRAINING HL8 STONE.
LENGTH ON TABLE 1, FROM THE FIRST RESTRAINED JOINT SHALL BE 5. ALL DIMENSIONS ARE IN MILLIMETRES.
RESTRAINED.

APPROVED DATE OF ISSUE

TOWNSHIP OF KING M.C. FEB. 1980

REVISION DRAWING No.

50mm BLOWOFF FOR WATERMAIN


WITH MECHANICALLY RESTRAINED JOINTS DATE OF REVISION KS-803
OCT. 2016
TRENCH WIDTH FINISHED GRADE
O.D. + MINIMUM 600

APPROVED EXCAVATED BACKFILL


COMPACTED TO 95% PROCTOR DENSITY

MINIMUM 1200
SAND

100
MINIMUM 1500

75
EXTRUDED POLYSTYRENE

150
INSULATION (STYROFOAM HI 40
OR APPROVED EQUIVALENT)

SAND BACKFILLED TO 98%


PROCTOR DENISTY

WATERMAIN

BEDDING MATERIAL AS SPECIFIED


ON CONTRACT DRAWINGS

INSULATION OF NEW SERVICES

APPROVED EXCAVATED
BACKFILL COMPACTED TO
95% PROCTOR DENSITY

FINISHED GRADE
362.9mm

SAND
H

W W
100

EXTRUDED POLYSTYRENE
INSULATION (STYROFOAM HI 40
OR APPROVED EQUIVALENT)
75

SAND BACKFILL COMPACTED


TO 98% PROCTOR DENSITY
150

. .
O.D O.D

EXISTING GROUND BELOW


SPRINGLINE OF THE PIPE
NOT TO BE DISTURBED

H >= 1350 WATERMAIN H < 1350

INSULATION OF EXISTING SERVICES

W = O.D. + 2(1500-H) OR O.D. + 600mm WHICHEVER IS GREATER


WHERE: W = INSULATION WIDTH
O.D. = OUTSIDE DIAMETER OF PIPE TO BE INSULATED
H = DEPTH OF PIPE TO BE INSULATED
(MINIMUM = 1200mm)

NOTES:
1. ALL DIMENSIONS ARE IN MILLIMETRES.

APPROVED DATE OF ISSUE

TOWNSHIP OF KING M.C. JAN. 1990

REVISION DRAWING No.

METHODS OF INSULATING
WATERMAINS DATE OF REVISION KS-804
NOV. 2009
WIDTH OF TRENCH

TIMBER OR STEEL BEAM


OF ADEQUATE SIZE GROUND ELEVATION

TEMPORARY HANGERS

DO NOT REMOVE HANGERS GRANULAR C

MIN.
GRANULAR C 300 300

300
UNTIL BACKFILLING
OPERATIONS REACH THIS
POINT

EXISTING SEWER O.D.


OR WATERMAIN
HL8 BLEND CRUSHED CLEAR
GREATER THAN 1200

LIMESTONE COMPACTED TO

H
MAX.
1200
95% PROCTOR DENSITY

MIN.
600
CLEARANCE

MINIMUM 300
O.D. + 600 +H

300
MIN.
600

CONCRETE SLAB
15 MPa AT 28 DAYS

NEW SEWER OR WATERMAIN

CLEARANCE GREATER THAN 1200

WIDTH OF TRENCH
TIMBER OR STEEL BEAM
OF ADEQUATE SIZE

GROUND ELEVATION

TEMPORARY HANGERS

GRANULAR C
DO NOT REMOVE
O.D. + 600
EXISTING SEWER HANGERS UNTIL
300 300 BACKFILLING
OR WATERMAIN
OPERATIONS REACH
THIS POINT

O.D.
HL8 BLEND CRUSHED CLEAR
NOT GREATER THAN 1200

LIMESTONE COMPACTED TO
95% PROCTOR DENSITY
CLEARANCE

O.D. + 600 +H

NEW SEWER OR
WATERMAIN
SECTION LONGITUDINAL SECTION

CLEARANCE NOT GREATER THAN 1200

NOTES:
1. ALL DIMENSIONS ARE IN MILLIMETRES.

APPROVED DATE OF ISSUE

TOWNSHIP OF KING M.C. JAN. 1990

REVISION DRAWING No.

SUPPORTS FOR WATERMAINS AND SEWERS


CROSSING WATERMAIN TRENCHES DATE OF REVISION KS-805
NOV. 2009
A SEE 1
LE
S
TA EE
TAB BLE
1
RESTRAINED JOINT
TRENCH WIDTH
20mm CRUSHER
RUN LIMESTONE
COMPACTED TO
95% PROCTOR 300 MIN.
DENSITY
E
PIP . O.D.
O.D

300 MIN.
75
S SECTION A-A
A TA EE
BLE
2
HORIZONTAL DEFLECTION

C
SE LE
TA

B RESTRAINED JOINT
E 2
B

SEE
TABLE 1

SE LE
TA

E 1
B
SE LE
TA

E 1
B

TRENCH BED TRENCH BED


SEE
TABLE 1

SE LE
TA

E 2
B
B NOTES:
1. ALL JOINTS ENCOUNTERED WITHIN THE SPECIFIED RESTRAINING
TRENCH WIDTH LENGTH OF BOTH SIDES OF DEFLECTION SHALL BE RESTRAINED.
2. REFER TO OPSD FOR JOINT RESTRAINING DETAIL.
20mm CRUSHER RUN 150
LIMESTONE COMPACTED
TO 95% PROCTOR E 3. GRANULAR THRUST BLOCKS SHALL BE FULLY EXTENDED AND
DENSITY PIP . O.D.
O.D COMPACTED AGAINST TRENCH WALLS.
4. GRANULAR THRUST BLOCKS SHALL BE ENCLOSED WITH FILTER
150
FABRIC IF GROUND WATER TABLE IS ABOVE THE TRENCH BED OR IF
CLEAR STONE FOUNDATION GROUND WATER IS SEEPING THROUGH TRENCH WALLS.
AS REQUIRED, SEE NOTE 5
5. IF THE BEARING CAPACITY OF TRENCH BED RESISTING DOWNWARD
THRUST IS LESS THAN 100 KN/m2, CLEAR STONE FOUNDATION SHALL
SECTION B-B BE PROVIDIED AS REQUIRED.
6. CORROSION PROTECTION SHALL ALSO BE PROVIDED.
DOWNWARD THRUST 7. ALL DIMENSIONS IN MILLIMETRES.
TABLE No. 1
VERTICAL DEFLECTION
PIPE DIAMETER
20mm CRUSHER RUN DEFLECTION
LIMESTONE COMPACTED ANGLE
TO 95% PROCTOR 150 200 250 300
DENSITY
400 500 550 600
400 500 550 600
TRENCH WIDTH 450 550 600 650
600 700 750 850

TABLE 2
300 MIN.
MINIMUM RESTRAINING LENGTH (m)
VERTICAL DELFECTION
E
PIP . O.D. PIPE HORIZONTAL DEFLECTION
O.D DATA
DOWNWARD THRUST UPWARD THRUST

75 150 1.2 2.1 4.0 4.8 7.6 9.2 1.2 2.1 4.0 6.0
SECTION C-C
200 1.5 3.0 4.9 6.7 9.7 11.3 1.5 3.0 4.9 7.9
UPWARD THRUST 250 1.8 3.6 6.4 9.0 12.2 14.0 1.8 3.6 6.4 9.0

300 2.1 4.3 7.3 10.9 14.7 16.6 2.1 4.3 7.3 11.9

APPROVED DATE OF ISSUE

TOWNSHIP OF KING M.C. JAN. 1990

REVISION DRAWING No.

JOINT RESTRAINING LENGTH


(IN COMBINATION WITH GRANULAR THRUST BLOCK)

FOR P.V.C. PIPE


DATE OF REVISION KS-830
NOV. 2015
FINISHED GRADE

SLIDE TYPE VALVE BOX

50mm OPERATING NUT


OPENING COUNTER CLOCKWISE

GUIDE PLATE

NON-RISING STEM

IRON BODY, BRONZE MOUNTED RESILIENT


SEAT GATE VALVE, MECHANICAL JOINT ENDS
CONFORMING TO A.W.W.A. C.509

GLAND RING
GASKET
20mm CRUSHER RUN LIMESTONE
150mm MIN.

20mm CRUSHER RUN LIMESTONE

SLIDE TYPE SOLID CONCRETE BLOCK

NOTES:
1. VALVE BOX TO BE ADEQUATELY BRACED WHILE BACKFILLING AND
MUST REMAIN PLUMB.
2. VALVE BOX EXTENSION TO BE USED ONLY IF REQUIRED.
3. A 50x100x1500 MARKER STAKE PAINTED BLUE SHALL BE INSTALLED
BESIDE EACH VALVE AT THE TIME OF INSTALLATION.
4. ALL DIMENSIONS ARE IN MILLIMETRES.
5. VALVE TO BE COMPLETELY BACKFILLED WITH 20mm CRUSHER RUN
LIMESTONE.
6. CORROSION PROTECTION SHALL ALSO BE PROVIDED.

APPROVED DATE OF ISSUE

TOWNSHIP OF KING M.C. FEB. 1980

REVISION DRAWING No.

150mm TO 250mm DIAMETER


GATE VALVE & BOX
DATE OF REVISION KS-840
NOV. 2009
B 1200mm MANHOLE

WATERMAIN

B
MINIMUM 3 CONCRETE MODULAR RINGS, PARGE
300 OUTSIDE AND PAINT WITH BITUMINOUS SEALER

PRECAST FLAT TOP


200

APPROVED RUBBER GASKET JOINTS,


MORTAR INSIDE AND OUT
1800 MINIMUM

WATERMAIN

TYPICAL CONCRETE SUPPORT

POURED OR PRECAST BASE

300mm
SQUARE 150
AIR RELEASE CHAMBER TO BE DRAINED TO
STORM SEWERS WITH 100mm DIAMETER
CONNECTIONS WHERE POSSIBLE 20mm CRUSHER RUN LIMESTONE
COMPACTED TO 75mm MINIMUM

650 850

25mm AUTOMATIC AIR RELEASE


25mm GATE VALVE

25mm GATE VALVE


25mm TEE

25mm BRASS NIPPLE


WATERMAIN

NOTES:
1. ALL FITTINGS TO BE BRASS.
2. ALL DIMENSIONS ARE IN MILLIMETRES.
3. GRANULAR 'C' BACKFILL TO BE PLACED TO A MINIMUM THICKNESS OF 300mm
ON ALL SIDES AND COMPACTED TO 100% STANDARD PROCTOR DENSITY.
3. SEE APPROVED MATERIAL LISTING FOR AIR RELEASE VALVE

APPROVED DATE OF ISSUE

TOWNSHIP OF KING M.C. JAN. 1990

REVISION DRAWING No.

AIR RELEASE CHAMBER DATE OF REVISION KS-843


FEB. 2017
APPROVED DATE OF ISSUE

TOWNSHIP OF KING M.C. OCT. 2010

REVISION DRAWING No.

COMBINATION AIR
AND VALVE CHAMBER DATE OF REVISION KS-844
NOV. 2015
APPROVED DATE OF ISSUE

TOWNSHIP OF KING M.C. JULY 2012

REVISION DRAWING No.


WATER METER INSTALLATION IN CHAMBER
(FOR COMBINED FIRE & DOMESTIC) DATE OF REVISION
APRIL 2015
KS-845
APPROVED DATE OF ISSUE

TOWNSHIP OF KING M.C.

REVISION DRAWING No.


WATER SERVICE CONNECTIONS FOR
SINGLE ICI / COMMON ELEMENT DATE OF REVISION KS-846
CONDOMINIUM BUILDING APRIL 2015
SUMP

APPROVED DATE OF ISSUE

TOWNSHIP OF KING M.C. MAY 2015

REVISION DRAWING No.

WATER METER CHAMBER DETAILS


(50mm SERVICE LINE)
DATE OF REVISION KS-847
CENTRELINE

STREETLINE
SWEEP FORMED IN A
HORIZONTAL PLANE

PLAN

STREETLINE
FINISHED GRADE

1.80m

PEX SERVICE TUBE

STAINLESS
STEEL SADDLE CURB STOP
MAIN STOP

WATERMAIN SEE NOTE 3


ELEVATION
CONCRETE BLOCK

NOTES:
1. ALL SERVICES TO BE AT 90 TO WATER MAIN UNLESS
OTHERWISE SPECIFIED.
2. SERVICE DEPTH TO MEET MINIMUM COVER AS
SPECIFIED BY DESIGN STANDARDS.
3. INSTALL 'FORD' SERVICE INSULATOR OR APPROVED
EQUAL BETWEEN THE CURB STOP AND THE STREET
LINE ONLY IF THE SERVICED BUILDING IS LOCATED 7.6m
OR MORE FROM THE STREETLINE.

4. NO DIRECT TAPPING OF PVC WATER MAINS. ALL


CONNECTIONS TO PVC PIPE TO BE MADE USING AN
APPROVED WIDE BAND SERVICE SADDLE.

5. TRACER WIRE AND CATHODIC PROTECTION TO BE


PROVIDED PER SECTION D7 OF THE DESIGN CRITERIA.

APPROVED DATE OF ISSUE

TOWNSHIP OF KING M.C. JAN. 1990

REVISION DRAWING No.

WATER SERVICE
(20mm - 50mm DIAMETER) DATE OF REVISION KS-851
OCT. 2016
14.5 kg MAGNESIUM ANODE
PROPOSED HYDRANT

1000mm PROPOSED 150mm WATERMAIN


MIN.

BONDING CABLES
(SEE NOTE 4 & 5)

PROPOSED ANCHOR TEE

PROPOSED D.I. NIPPLE

EXISTING D.I. OR PROPOSED SOLID SLEEVE


C.I. WATERMAIN
1500mm
MIN.

BONDING CABLES
(SEE NOTE 4 & 5)

14.5kg MAGNESIUM
ANODE 3000 MAX. EXISTING D.I. OR
C.I. WATERMAIN

NOTES:
1. ANODE TO BE PLACED AT LEAST 1.0m AWAY FROM THE FITTINGS AND
AS DEEP AS THE BOTTOM OF THE FITTINGS. MINIMUM DISTANCE
BETWEEN ANODES TO BE 1.0m.
2. ALL FITTINGS TO BE COATED WITH BITUMINOUS SEALER ON SITE.
3. PROVIDE 0.20mm POLYETHYLENE BOND BREAKER BETWEEN
CONCRETE AND FITTINGS.
4. ALL THERMITE WELD CONNECTIONS TO BE COATED WITH "ROYBOND
747" PRIMER AND ROYSTON "HANDY CAP" OR APPROVED EQUAL.
5. BONDING CABLE TO BE NO. 6, SEVEN STRAND COATED COPPER WIRE,
CAD WELD TO FITTINGS.

APPROVED DATE OF ISSUE

TOWNSHIP OF KING M.C. JAN. 1990

REVISION DRAWING No.

CORROSION PROTECTION FOR HYDRANT CUT


INTO AN EXISTING D.I. OR C.I. WATERMAIN
DATE OF REVISION KS-854
NOV. 2015
DRILLED HOLE IN VALVE BOX

VALVE BOX

NOTES:
1. TRACER WIRE - #12 GAUGE STRANDED, C.S.A. TYPE T.W.H.
2. TRACER WIRE TO BE INSTALLED OUTSIDE LOWER VALVE BOX AND
BROUGHT INTO UPPER SECTION OF VALVE BOX AND LOOPED AT TOP.
LOOP TO BE A MINIMUM 450mm IN LENGTH.
3. CONNECTORS USED FOR SPLICING TRACER WIRE SHALL BE WING NUT
TYPE, WITH NYLON SHELL AND NON-CORROSIVE STEEL WIRE SPRING.

APPROVED DATE OF ISSUE

TOWNSHIP OF KING M.C. JAN. 1990

REVISION DRAWING No.

TRACER WIRE ARRANGEMENT AT VALVE


BOX FOR P.V.C OR C.P.P. WATERMAIN
DATE OF REVISION KS-860
NOV. 2009
A SERVICE CONNECTOR (SEE NOTE 3)

MASTIC MATERIAL
(SEE NOTE 4) TRACER WIRE (SEE NOTE 1)

P.V.C. OR C.P.P. WATERMAIN


2.3 kg ZINC ANODE
(SEE NOTE 2)

ELEVATION

MASTIC MATERIAL SERVICE CONNECTOR (SEE NOTE 3)


(SEE NOTE 4)
TRACER WIRE (SEE NOTE 1)

COATED COPPER WIRE P.V.C. OR C.P.P.


WATERMAIN

2.3 kg ZINC ANODE


(SEE NOTE 2)

50 MINIMUM

1000 MINIMUM

SECTION A-A

NOTES:
1. TRACER WIRE - #12 GAUGE STRANDED, C.S.A. TYPE T.W.H.
2. ONE 2.3 kg ZINC ANODE TO BE SUPPLIED AND INSTALLED IN A MANNER
APPROVED BY THE TOWNSHIP ENGINEER FOR EVERY 500m OF
TRACER WIRE INSTALLED.
3. SERVICE CONNECTOR TO BE A 'BURNDY SERVIT' TYPE K.S. MODEL
KS20 COPPER OR APPROVED EQUAL.
4. CONNECTOR SPLICE TO BE WRAPPED WITH 'SCOTCHFILL' ELECTRICAL
PUTTY OR APPROVED EQUAL.
5. ALL DIMENSIONS ARE IN MILLIMETRES.
6. THE LOCATION OF EACH TRACER WIRE ANODE MUST BE DETAILED ON
THE CONTRACT DRAWINGS.

APPROVED DATE OF ISSUE

TOWNSHIP OF KING M.C. JAN. 1990

REVISION DRAWING No.

CORROSION PROTECTION FOR TRACER


WIRES ON P.V.C. OR C.P.P. WATERMAINS
DATE OF REVISION KS-870
NOV. 2009
A
CENTRELINE
OF VALVE

THERMITE WELD (CADWELD)


SEE NOTE 4
1000 MIN.

5.4 kg ZINC ANODE


5.4 kg ZINC ANODE

A SECTION A-A

CORROSION PROTECTION FOR VALVES (TYPICAL)


B

THERMITE WELD (CADWELD)


SEE NOTE 4 GRANULAR
THRUST BLOCK

1000 MIN.

B
5.4 kg ZINC ANODE

SECTION B-B

5.4 kg ZINC ANODE RESTRAINED JOINT


FITTINGS (TYPICAL)

CORROSION PROTECTION FOR FITTINGS (TYPICAL)

NOTES:
1. ANODE TO BE PLACED AT LEAST 1.0m AWAY FROM THE FITTING AND
AS DEEP AS THE BOTTOM OF THE FITTINGS. MINIMUM DISTANCE
BETWEEN ANODES TO BE 1.0m.
2. ALL VALVES AND FITTINGS TO BE COATED WITH BITUMINOUS SEALER
PRIOR TO INSTALLATION ON SITE.
3. ALL DIMENSIONS ARE IN MILLIMETRES.

4. PROVIDE 0.2m POLYETHYLENE BOND BREAKER BETWEEN CONCRETE


AND FITTINGS.
5. ALL THERMITE WELD CONNECTIONS TO BE COATED WITH 'ROYBOND
747' PRIMER AND ROYSTON 'HANDY CAP' OR APPROVED EQUAL.
APPROVED DATE OF ISSUE

TOWNSHIP OF KING M.C. JAN. 1990

REVISION DRAWING No.

CORROSION PROTECTION FOR VALVES


& FITTINGS ON NON-FERROUS PIPE
DATE OF REVISION KS-871
NOV. 2009
BONDING CABLE
(SEE NOTE 2 AND 3)

EXISTING C.I. OR
D.I. WATERMAIN
PROPOSED C.I. SOLID SLEEVE

1000 MINIMUM

PROPOSED NON-FERROUS WATERMAIN

14.5 kg MAGNESIUM ANODE

3000 MAXIMUM

NOTES:
1. ANODE TO BE PLACED AT LEAST 1.0m AWAY FROM THE FITTING AND
AS DEEP AS THE BOTTOM OF THE FITTINGS. MINIMUM DISTANCE
BETWEEN ANODES TO BE 1.0m.
2. ALL THERMITE WELD CONNECTIONS TO BE COATED WITH 'ROYBOND
747' PRIMER AND ROYSTON 'HANDY CAP' OR APPROVED EQUAL.

3. BONDING CABLE TO BE No. 6 SEVEN STRAND COATED COPPER WIRE,


CADWELDED TO FITTINGS.
4. ALL DIMENSIONS IN MILLIMETRES.

APPROVED DATE OF ISSUE

TOWNSHIP OF KING M.C. JAN. 1990

REVISION DRAWING No.


CORROSION PROTECTION FOR EXISTING
FERROUS WATERMAIN CONNECTED TO DATE OF REVISION KS-873
PROPOSED NON-FERROUS WATERMAIN NOV. 2009
A

CENTRELINE CENTRELINE
OF HYDRANT OF HYDRANT

SIDE PORTS
875 MAXIMUM

SIDE PORTS
CENTRELINE
OF VALVE
MIN.
75

GRANULAR
THRUST BLOCKS

GRANULAR BONDING
THRUST BLOCKS CABLE SEE
SEE KS-808 NOTE 4 & 5

THERMITE WELD (CADWELD)


(SEE NOTE 4)
1000 MIN.

ANCHOR TEE
5.4 kg ZINC ANODE

A CENTRELINE OF
RESTRAINED JOINT 5.4 kg ZINC ANODE WATERMAIN
FITTING (TYPICAL)

SECTION A-A ELEVATION

NOTES:
1. ANODE TO BE PLACED AT LEAST 1.0m AWAY FROM THE FITTINGS AND
AS DEEP AS THE BOTTOM OF THE FITTINGS. MINIMUM DISTANCE
BETWEEN ANODES TO BE 1.0m
2. ALL FITTINGS TO BE COATED WITH BITUMINOUS SEALER ON SITE.
3. ALL DIMENSIONS ARE IN MILLIMETRES.

4. ALL THERMITE WELD CONNECTIONS TO BE COATED WITH 'ROYBOND


747' PRIMER AND ROYSTON 'HANDY CAP' OR APPROVED EQUAL.
5. BONDING CABLE TO BE No. 6 SEVEN STRAND COATED COPPER WIRE,
CADWELDED TO FITTINGS.

APPROVED DATE OF ISSUE

TOWNSHIP OF KING M.C. JAN. 1990

REVISION DRAWING No.

CORROSION PROTECTION FOR HYDRANT


ASSEMBLY ON NON-FERROUS PIPE
DATE OF REVISION KS-874
NOV. 2015
14.5 kg MAGNESIUM ANODE
PROPOSED HYDRANT

1000mm
MIN.

BONDING CABLES
(SEE NOTE 4 & 5)

PROPOSED ANCHOR TEE

D.I. WATERMAIN D.I. WATERMAIN


1500mm
MIN.

BONDING CABLES
(SEE NOTE 4 & 5)

14.5kg MAGNESIUM
ANODE 3000 MAX.

NOTES:
1. ANODE TO BE PLACED AT LEAST 1.0m AWAY FROM THE FITTINGS AND
AS DEEP AS THE BOTTOM OF THE FITTINGS. MINIMUM DISTANCE
BETWEEN ANODES TO BE 1.0m
2. ALL FITTINGS TO BE COATED WITH BITUMINOUS SEALER ON SITE.
3. PROVIDE 0.20mm POLYETHYLENE BOND BREAKER BETWEEN
CONCRETE AND FITTINGS.
4. ALL THERMITE WELD CONNECTIONS TO BE COATED WITH "ROYBOND
747" PRIMER AND ROYSTON "HANDY CAP" OR APPROVED EQUAL.
5. BONDING CABLE TO BE No. 6, SEVEN STRAND COATED COPPER WIRE,
CAD WELD TO FITTINGS.

APPROVED DATE OF ISSUE

TOWNSHIP OF KING M.C. JAN. 1990

REVISION DRAWING No.

CORROSION PROTECTION FOR HYDRANTS


OFF OF D.I. WATERMAINS
DATE OF REVISION KS-875
NOV. 2015
PLUG TAPPED FOR 50mm

HYD. NEAR LAST LOT LINE AT


START OF BULB
150mm VALVE & BOX
TEE WITH PLUG TAPPED
50mm CORPORATION STOP FOR 50mm
(NOTE 1) WATERMAIN

NOTES:
1. VALVE AND BOX IS NOT TO BE LOCATED WITHIN TRAVELED PORTION
OR ROAD.

APPROVED DATE OF ISSUE

TOWNSHIP OF KING M.C.

REVISION DRAWING No.

WATERMAIN CONFIGURATION FOR


DEAD END CUL-DE-SACS
DATE OF REVISION KS-877
SEP, 2016
3.6m

1.5m
PL
0.9m

1.5m x 1.2m RUBBER ECOFLEX MAT

SAMPLING PIPE

DRAIN PIPE

50mm RUBBER ECOFLEX MAT

50mm HIGH PERFORMANCE BEDDING


1.2m
SUBGRADE COMPACTED TO 98% SPD

1.5m

1.8m

1" DOMESTIC PIPE 1" CURBSTOP 1" PEX PIPE

1" MAINSTOP

1" FIP INLET


30cm x 30cm CONCRETE SLAB

NOTES:

1. SAMPLING STATIONS TO BE WITH 'TEST TAP' (CROMER), OR EQUIVALENT.

2. SAMPLING STATIONS SHALL BE EQUIPPED WITH A 3/8" 316 STAINLESS STEEL VENT TUBE. THIS IS USED TO PUMP STANDING WATER FROM THE UNIT
AFTER USE, PREVENTING FREEZING AND BACTERIA GROWTH

3. THE ENCLOSURE SHALL BE MADE FROM SCHEDULE 40 PVC PIPE WITH LOCKABLE ACCESS DOOR

4. THE ENCLOSURE SHALL PROTECT ALL COMPONENTS FROM CORROSIVE SOIL AND GROUND WATER

5. AFTER THE WATER IS TURNED OFF AT THE CURBSTOP, ALL WORKING PARTS SHALL BE REMOVABLE WITHOUT DIGGING OR USE OF ANY TOOLS

6. SAMPLING STATIONS WILL BE EQUIPPED WITH A 1" FIP INLET FOR THE CONNECTION TO THE WATERMAIN

7. STANDARD TEST TAP IS DESIGNED FOR A 1.8m (6 FEET) BURY AND AND 1.2m (4 FEET) PEDESTAL

8. TEST TAP AND CURBSTOP SHOULD REST ON CONCRETE SLAB. 30cm X 30cm PATIO SLAB IS ACCEPTIBLE

9. NO LEAD FITTINGS (MAINSTOP, CURBSTOP ETC.) ARE TO BE USED

APPROVED DATE OF ISSUE

TOWNSHIP OF KING M.C. FEB. 2010

REVISION DRAWING No.

SIDE VIEW OF SAMPLING


STATION INSTALLATION
DATE OF REVISION KS-878
OCT, 2016

You might also like