Download as pdf or txt
Download as pdf or txt
You are on page 1of 30

DRX 125 HP

DRX 250 HP
& DRX 630

THE MCCBs
THAT EASILY FIT
YOUR INSTALLATION

THE GLOBAL SPECIALIST


IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES
AN
ENHANCED
OFFER
DRX 125 & 250
With the arrival of the new DRX 125 and
250 HP, Legrand has enhanced its offer
of thermal magnetic MCCBs to meet
your requirements even more effectively.
Designed to extend the existing DRX
range, the HP releases and the DRX 630
combine simplicity and robustness with
safety and reliability.

• Designed for residential and commercial


applications
• For installations up to 250 A (breaking capacity
≤ 25 kA) with no specific constraints
Whatever your application,
the level of protection
required, or your specific
budget, Legrand has a
reliable solution for you!

DRX 125 HP, 250 HP & 630


FIXED & ADJUSTABLE

NEW
DPX3

• Designed for residential, commercial or • For installations up to 1600 A (breaking capacity


industrial applications ≤ 100 kA) requiring high-precision protection,
excellent continuity of service, measurement
• For installations up to 630 A (breaking capacity
of different electrical values and multiple
≤ 50 kA) requiring a greater degree of flexibility
configurations
in the choice of trip thresholds to provide more
adaptable protection • Ensuring scalability and ease of maintenance

THERMAL MAGNETIC MCCBs DRX 125 HP, DRX 250 HP & DRX 630 1
WWW.LEGRAND.COM
THE NEW
DRX 125 HP
DRX 250 HP
& DRX 630
OFFER
A COMPREHENSIVE RANGE UP TO 630 A
The DRX 125 HP, DRX 250 HP and DRX 630 ranges of fixed
and adjustable thermal magnetic circuit breakers have
been designed to meet your requirements when it comes to
protecting an electrical installation up to 630 A.
The robust design of the DRX range, the adjustable
protection, the different accessories for connection and
remote tripping have made it the ideal choice in terms of
efficiency and affordability.

THE RIGHT ANSWER IN TERMS OF:


CHOICE RELIABILITY ADAPTABILITY
 Three different sizes  SEMKO - LOVAG certification  Fixing on plate
 Ratings ranging from 16 to 630 A  Compliant with standard IEC 60947-2  Dedicated accessories for integration
 Three breaking capacities: 25, 36  Mechanical endurance up to into XL3 S 630 and 4 000 enclosures
and 50 kA 20,000 operations  Wiring via cables or busbars

DRX 125 HP DRX 125 HP


THE RANGE
fixed version adjustable version

Mounting ON PLATE ON PLATE

Rated current (In) From 16 to 125 A From 16 to 125 A

Breaking capacity (Icu) at 415 V 25 kA, 36 kA, 50 kA 25 kA, 36 kA, 50 kA


Rated service short-circuit breaking
capacity Ics (% Icu) 100 100

Thermal (Ir) Fixed at 1.0 x In Adjustable: 0.8 - 0.9 - 1.0 x In


Protection Fixed: 400 A, for In up to 40 A Fixed: 400 A, for In up to 40 A
Magnetic (Ii)
10 x In, for 50 A ≤ In ≤ 125 A 10 x In, for 50 A ≤ In ≤ 125 A
Number of poles 3P and 4P 3P and 4P

(1) : See page 10 for more detailed information


2
A solution
adapted to
numerous
different sites,
whether
residential,
commercial or
even in the
industrial sector.

DRX 250 HP DRX 250 HP DRX 630 DRX 630


fixed version adjustable version fixed version adjustable version

ON PLATE ON PLATE ON PLATE ON PLATE

From 16 to 250 A From 16 to 250 A From 320 to 630 A From 320 to 630 A

25 kA, 36 kA, 50 kA 25 kA, 36 kA, 50 kA 36 kA, 50 kA 36 kA, 50 kA

100 100 50 100

Fixed at 1.0 x In Adjustable (1): 0.8 - 0.9 - 1.0 x In Fixed at 1.0 x In Adjustable: 0.8 - 0.9 - 1.0 x In

Fixed at 10 x In Adjustable (1): 5 - 7.5 - 10 x In Fixed at 10 x In Adjustable: 5 - 10 x In

3P and 4P 3P and 4P 3P and 4P 3P and 4P

THERMAL MAGNETIC MCCBs DRX 125 HP, DRX 250 HP & DRX 630 3
WWW.LEGRAND.COM
Clear, simple, indelible marking
on the front of the MCCB stating:
- the thermal magnetic protection,
- the rated current, Clear identification of the state
- the breaking capacity. of the circuit breaker:
I = On
0 = Off

Magnetic adjustment:
Thermal adjustment:
Ii from 5 to 10 x In
Ir from 0.8 to 1 x In
on the adjustable version(1)
on the adjustable version

Test button

DRX 250 HP ADJUSTABLE VERSION DRX 250 HP FIXED VERSION

FLEXIBLE
SOLUTIONS TO
AN ADJUSTED PROTECTION
3 circuit breakers sizes covering all
needs when it comes to providing
protection against overloads and
short-circuits, for sites up to 630 A.
The adjustable version gives
the possibility to adjust thermal
(protection against overloads) and
magnetic(1) (protection against short-
circuits) tripping levels.

(1) : Except DRX 125 HP adjustable


4
Clear, simple, indelible marking Clear identification of the state
on the front of the MCCB stating: of the circuit breaker:
- the thermal magnetic protection, I = On
- the rated current, 0 = Off
- the breaking capacity.

Thermal adjustment: Ir from 0.8 to 1 x In


(on the adjustable version)
Magnetic adjustment:
Ii from 5 to 10 x In
(on the adjustable version)

Test button

DRX 630 ADJUSTABLE VERSION DRX 630 FIXED VERSION

ANSWER ALL NEEDS


SOLUTIONS FOR ALL TYPES OF SITES
The comprehensive DRX range
provides solutions suiting:
- any installation merely requiring a
certain flexibility when it comes to
protecting the electric circuits,
- all residential, commercial or
industrial sites requiring protection
and remote tripping functions.

THERMAL MAGNETIC MCCBs DRX 125 HP, DRX 250 HP & DRX 630 5
WWW.LEGRAND.COM
ROBUST DESIGN
RELIABILITY
SAFETY With the DRX HP range, you
can guarantee long-term
protection for your customers’
installations.
Its rugged construction ensures
continuity of operation even in
excessive temperatures.

TEST OF ENDURANCE QUALITY LEVEL


The DRX has proven mechanical Guaranteed by SEMKO and LOVAG
endurance up to 20,000 operations. certifications.
Compliant with standard IEC 60947-2.

6
REMOTE TRIPPING FOR SAFETY


The control and signalling
auxiliaries simply clip on.

RISK-FREE INTERVENTION
The padlock can be used to lock the
handle in “Open” position during
maintenance operations and thus avoid
any risk of accidents due to mishandling.

FACEPLATE PROTECTION
No live parts are
accessible once installed
under a faceplate.

THERMAL MAGNETIC MCCBs DRX 125 HP, DRX 250 HP & DRX 630 7
WWW.LEGRAND.COM
EASE
OF INSTALLATION
AND WIRING
The DRX 125 HP, DRX 250 HP and DRX 630 ranges
include numerous accessories which make wiring and
installation easier and allow remote tripping, saving
time during installation.

EASE OF INSTALLATION
AND FLEXIBILITY
MCCB easily positioned and
removed from the fixing plate.
Wide choice of fixing accessories
for integration into XL3 S 630
and 4 000 enclosures (horizontal
or vertical position and 16, 24 and
36 modules wide enclosures)

A VARIETY OF WIRING SYSTEM OPTIONS

Numerous wiring The size of the terminals Cable spreaders, cage terminals,
accessories are available is optimized for connection rear terminals, terminal shields, etc;
to assist installation. via busbars. our wiring accessories cover all your
requirements.

8
ROTARY HANDLE
The rotary handle, is available in
direct or external version in order
to accommodate different users’
habits or the specific constraints
affecting each type of site.
It is simple and quick to fit.

HORIZONTAL OPERATION
If required DRX 125 HP, DRX 250 HP
and DRX 630 can be also installed
horizontally, according to the size and
type of enclosure.

THERMAL MAGNETIC MCCBs DRX 125 HP, DRX 250 HP & DRX 630 9
WWW.LEGRAND.COM
DRX 125 HP TM
DRX 125 HP adjustable
TM

thermal magnetic MCCBs from 16 to 125 A thermal magnetic MCCBs from 16 to 125 A

6 693 89 6 693 99 6 697 49 6 697 59

Technical characteristics and curves p. 12-13 Technical characteristics and curves p. 12-13
Dimensions and installation principle p. 14-15 Dimensions and installation principle p. 14-15
For switching, control, isolation and protection of low-voltage electrical For switching, control, isolation and protection of low-voltage electrical
lines. Can be fitted with auxiliaries. Supplied with: screw terminals, fixing lines. Can be fitted with auxiliaries. Supplied with: screw terminals, fixing
screws, insulating shields (2 for 3P and 3 for 4P). screws, insulating shields (2 for 3P and 3 for 4P).
Fixed thermal and magnetic Adjustable thermal
Conform to IEC 60947-2 Fixed magnetic
Conform to IEC 60947-2
Pack Cat.Nos DRX 125 HP
Pack Cat.Nos DRX 125 HP
Breaking capacity Icu 25 kA (415 VA)
3P 4P In Thermal adjustable from 0.8 to 1 x In
1 6 693 40 6 693 50 16 A Breaking capacity Icu 25 kA (415 VA)
1 6 693 41 6 693 51 20 A 3P 4P In
1 6 693 42 6 693 52 25 A 1 6 697 00 6 697 10 16 A
1 6 693 43 6 693 53 32 A 1 6 697 01 6 697 11 20 A
1 6 693 44 6 693 54 40 A 1 6 697 02 6 697 12 25 A
1 6 693 45 6 693 55 50 A 1 6 697 03 6 697 13 32 A
1 6 693 46 6 693 56 63 A 1 6 697 04 6 697 14 40 A
1 6 693 47 6 693 57 80 A 1 6 697 05 6 697 15 50 A
1 6 693 48 6 693 58 100 A 1 6 697 06 6 697 16 63 A
1 6 693 49 6 693 59 125 A 1 6 697 07 6 697 17 80 A
Breaking capacity Icu 36 kA (415 VA) 1 6 697 08 6 697 18 100 A
In 1 6 697 09 6 697 19 125 A
1 6 693 60 6 693 70 16 A Breaking capacity Icu 36 kA (415 VA)
1 6 693 61 6 693 71 20 A In
1 6 693 62 6 693 72 25 A 1 6 697 20 6 697 30 16 A
1 6 693 63 6 693 73 32 A 1 6 697 21 6 697 31 20 A
1 6 693 64 6 693 74 40 A 1 6 697 22 6 697 32 25 A
1 6 693 65 6 693 75 50 A 1 6 697 23 6 697 33 32 A
1 6 693 66 6 693 76 63 A 1 6 697 24 6 697 34 40 A
1 6 693 67 6 693 77 80 A 1 6 697 25 6 697 35 50 A
1 6 693 68 6 693 78 100 A 1 6 697 26 6 697 36 63 A
1 6 693 69 6 693 79 125 A 1 6 697 27 6 697 37 80 A
Breaking capacity Icu 50 kA (415 VA) 1 6 697 28 6 697 38 100 A
In 1 6 697 29 6 697 39 125 A
1 6 693 80 6 693 90 16 A Breaking capacity Icu 50 kA (415 VA)
1 6 693 81 6 693 91 20 A In
1 6 693 82 6 693 92 25 A 1 6 697 40 6 697 50 16 A
1 6 693 83 6 693 93 32 A 1 6 697 41 6 697 51 20 A
1 6 693 84 6 693 94 40 A 1 6 697 42 6 697 52 25 A
1 6 693 85 6 693 95 50 A 1 6 697 43 6 697 53 32 A
1 6 693 86 6 693 96 63 A 1 6 697 44 6 697 54 40 A
1 6 693 87 6 693 97 80 A 1 6 697 45 6 697 55 50 A
1 6 693 88 6 693 98 100 A 1 6 697 46 6 697 56 63 A
1 6 693 89 6 693 99 125 A 1 6 697 47 6 697 57 80 A
1 6 697 48 6 697 58 100 A
1 6 697 49 6 697 59 125 A

10
DRX 125 HP accessories
TM

0 271 76 0 271 80 0 271 40 0 271 51 0 271 65

Pack Cat.Nos Rotary handles Pack Cat.Nos Control and signalling auxiliaries for
DRX 125, 250, DRX 125 HP and DRX 250 HP
Direct
1 0 271 76 Standard (grey) Auxiliary contact blocks
Vari-depth handle For left-hand side mounting
Up to 250 VA and =
Comprising: connecting rod, bracket,
drilling template, mounting accessories,
1 0 271 40 Block with 1 auxiliary
door locking mechanism
1 0 271 41 Block with 1 alarm
1 0 271 42 Block with 1 auxiliary + 1 alarm
1 0 271 77 Standard (grey)
Shunt trips
Connection accessories 1 0 271 50 12 VA and =
1 0 271 51 24 VA and =
Insulating shields 1 0 271 52 48 VA and =
Used to isolate the connection 1 0 271 53 100/130 VA
between each pole 1 0 271 54 200/277 VA
3P 4P For DRX 125 HP and DRX 250 HP 1 0 271 55 380/480 VA
1 6 693 00 Set of 2 Undervoltage releases
1 6 693 01 Set of 3 1 0 271 60 12 VA and =
Sealable terminal shields 1 0 271 61 24 VA and =
1 6 693 08 6 693 09 Set of 2 1 0 271 62 48 VA and =
1 0 271 68 110 V=
Cage terminals 1 0 271 63 110/130 VA
1 6 693 02 6 693 03 Up to 125 A 1 0 271 64 200/240 VA
High capacity cage terminals 1 0 271 67 277 VA
3P 4P Up to 125 A 1 0 271 65 380/415 VA
1 6 693 18 Set of 3
1 0 271 66 440/480 VA
1 6 693 19 Set of 4
Spreaders
1 6 693 16 6 693 17 Set of incoming or outgoing spreaders
Rear terminals
Used to convert a fixed version with front
terminals into a fixed version with rear
terminals
1 6 693 06 Set of 3 rear terminals
1 6 693 07 Set of 4 rear terminals
Padlock for DRX 125, 250,
DRX 125 HP and DRX 250 HP
1 0 271 80 For locking on "OFF" position
(up to 3 locks)

11
DRX 125 HP
TM
DRX 125 HP adjustable
TM

technical characteristics technical characteristics

n Electrical and mechanical characteristics n Electrical and mechanical characteristics


DRX 125 HP DRX 125 HP DRX 125HP DRX 125 HP DRX 125 HP DRX 125HP
25 kA 36 kA 50 kA 25 kA 36 kA 50 kA

Number of poles 3P - 4P 3P - 4P 3P - 4P Number of poles 3P - 4P 3P - 4P 3P - 4P


Release type thermal-magnetic Release type thermal-magnetic

Rated current In (A) 16, 20, 25, 32, 40, 50, 63, 80, 100, 125 Rated current In (A) 16, 20, 25, 32, 40, 50, 63, 80, 100, 125

Rated insulation voltage Ui (V) 800 800 800 Rated insulation voltage Ui (V) 800 800 800
Rated operating voltage (50/60 Hz) Ue (V) 550 550 550 Rated operating voltage (50/60 Hz) Ue (V) 550 550 550
Rated impulse withstand Voltage Uimp (kV) 8 8 8 Rated impulse withstand Voltage Uimp (kV) 8 8 8
Rated frequency (Hz) 50 - 60 50 - 60 50 - 60 Rated frequency (Hz) 50 - 60 50 - 60 50 - 60
Reference ambient temperature Tamb (°C) 40 - 50 40 - 50 40 - 50 Reference ambient temperature Tamb (°C) 40 - 50 40 - 50 40 - 50
Operating temperature (°C) -25 to 70 -25 to 70 -25 to 70 Operating temperature (°C) -25 to 70 -25 to 70 -25 to 70
220/240 V± 40 70 90 220/240 V± 40 70 90
380/415 V± 25 36 50 380/415 V± 25 36 50
Rated ultimate short-circuit Rated ultimate short-circuit
breaking capacity Icu (kA) 440/460 V± 20 30 45 breaking capacity Icu (kA) 440/460 V± 20 30 45
IEC 60947-2 IEC 60947-2
480/500 V± 4 4 4 480/500 V± 4 4 4
550 V± 4 4 4 550 V± 4 4 4

Rated service short-circuit breaking capacity Rated service short-circuit breaking capacity
100 100 100 100 100 100
Ics (% Icu) Ics (% Icu)

Rated short-circuit making capacity Icm (kA) Rated short-circuit making capacity Icm (kA)
52.5 75.6 105 52.5 75.6 105
at 415 V± at 415 V±

Neutral protection for 4P version (% Ith) 100 100 100 Neutral protection for 4P version (% Ith) 100 100 100
220/240 V± 40 70 90 220/240 V± 40 70 90
Rated ultimate short-circuit Rated ultimate short-circuit
breaking capacity Icu (kA) 480/500 V± 4 4 4 breaking capacity Icu (kA) 480/500 V± 4 4 4
NEMA AB-1 NEMA AB-1
550 V± 4 4 4 550 V± 4 4 4
Category of use A A A Category of use A A A
Suitable for isolation Yes Yes Yes Suitable for isolation Yes Yes Yes
Thermal adjustment Ir (A) Fixed at 1.0 x In Thermal adjustment Ir (A) 0.8 - 0.9 - 1.0 x In

Fixed : 400 A, for In up to 40 A Fixed : 400 A, for In up to 40 A


Magnetic adjustment Ii (A) Magnetic adjustment Ii (A)
10 x In, for 50 A ≤ In ≤ 125 A 10 x In, for 50 A ≤ In ≤ 125 A

mechanical 20000 20000 20000 mechanical 20000 20000 20000


Endurance (cycles) electrical at In 8000 8000 8000 Endurance (cycles) electrical at In 8000 8000 8000
electrical at 0.5 In 8000 8000 8000 electrical at 0.5 In 8000 8000 8000
Neutral protection for 4P version (%) 100 100 100 Neutral protection for 4P version (%) 100 100 100
3P 75 x 130 x 86 3P 75 x 130 x 86
Dimensions W x H x D (mm) Dimensions W x H x D (mm)
4P 100 x 130 x 86 4P 100 x 130 x 86
3P 0.95 3P 0.95
Weight (kg) Weight (kg)
4P 1.15 4P 1.15

12
DRX 125 HP TM

tripping curves

n Curves
Thermal magnetic tripping curve (In = 16 A - 80 A) Cut-off peak current characteristic curve (kA)
Icu = 25 / 36 / 50 kA Imax = 80 A 3P - 4P Ue = 415 VA Icu = 25 / 36 / 50 kA Imax = 125 A 3P - 4P Ue = 415 VA
104 103

t (s)

103

In ≥ 40 A 102
102
li = 10 x ln

36 kA
50 kA
101 2 25 kA
In = 32 A
li = 12,5 x ln In = 100, 125 A
In = 63, 80 A
In = 25 A
li = 16 x ln In = 32, 40, 50 A
100 In = 20 A 101 In = 16, 20, 25 A
li = 20 x ln
In = 10 A
li = 25 x ln
10-1

10-2 100
100 101 102 100 101 102
I/Ir I/In

t = time Icc = estimated short circuit symmetrical current (RMS value)


I = current Ip = maximum short circuit peak current
In = rated current = maximum prospective short circuit peak
Ir = long time setting current current corresponding at the power factor
curve 1 = characteristic with cold start = maximum real peak short circuit current
curve 2 = characteristic with hot start

Thermal magnetic tripping curve (In = 100 A - 125 A) Pass-through specific energy characteristic curve
Icu = 25 / 36 / 50 kA Imax = 125 A 3P - 4P Ue = 415 VA Icu = 25 / 36 / 50 kA Imax = 125 A 3P - 4P Ue = 415 VA
10 4
108

t (s)
I2t (A2s)

103
107
50 kA

1 36 kA
102 25 kA

106
In = 100,125 A
li = 10 x ln
101
In = 100, 125 A
In = 63, 80 A
105 In = 32, 40, 50 A
2
10 0 In = 16, 20, 25 A

104
10-1

10-2 103
100 101 102 103 104 105
I/Ir I/In Icc (A)

t = time Icc = short circuit current


I = current I2t (A2s) = pass-through specific energy
In = rated current
Ir = long time setting current
curve 1 = characteristic with cold start
curve 2 = characteristic with hot start

13
DRX 125 HP TM

dimensions and mounting principle

n Dimensions
3P 4P

25 25
= = = =
111

111
130

130

25 25 25 25

75 100 87

112

n Mounting principale
Door cut-out
2
3P 4P Fixing on plate
Y Y
3P

111
52

52

77 102
= = = =
29,5

29,5

Ø3.65 or M4 = =
25
25 50
87

112

3P 4P 2 4P
Y Y
Y

24 24
111

X
52

52

0,5 0,5
29,5

29,5

25 25

25 50 93

112

14
DRX 125 HP
TM

dimensions (continued) and connection

n Connection
Connection via busbar
1

24
≤ 7
2
Ø 6,5
1
2
CLAC ≤ 17

D
3

M6 x 12,6
≥ 8,5
≤ 9 4
7 Nm
Ø 6,5

≤ 17

Connection via cable


With cage terminals Cat.No 6 693 02 (3P) or 6 693 03 (4P)

6 693 02 (3P) DRX 125 HP


6 693 03 (4P)
Flexible
2.5 mm2 _ 50 mm2
2 # 14 _ # 1/0 AWG
1 or

14
Solid
1 2.5 mm2 _ 50 mm2
3 # 14 _ # 1/0 AWG

CLAC
2

15
DRX 250 HP TM
DRX 250 HP adjustable
TM

thermal magnetic MCCBs from 16 to 250 A thermal magnetic MCCBs from 16 to 250 A

6 674 19 6 674 34 6 690 90 6 691 10

Technical characteristics and curves p. 18-19 Technical characteristics and curves p. 18-19
Dimensions and installation principle p. 20-21 Dimensions and installation principle p. 20-21
For switching, control, isolation and protection of low-voltage electrical For switching, control, isolation and protection of low-voltage electrical
lines. Can be fitted with auxiliaries. Supplied with: screw terminals, fixing lines. Can be fitted with auxiliaries. Supplied with: screw terminals, fixing
screws, insulating shields (2 for 3P and 3 for 4P). screws, insulating shields (2 for 3P and 3 for 4P).
Fixed thermal and magnetic Adjustable thermal and magnetic
Conform to IEC 60947-2 Conform to IEC 60947-2
Pack Cat.Nos DRX 250 HP Pack Cat.Nos DRX 250 HP
Breaking capacity Icu 25 kA (415 VA) Thermal adjustable from 0.8 to 1 x In
3P 4P In Magnetic adjustable from 5 to 10 x In
1 6 694 10 6 694 25 16 A Breaking capacity Icu 25 kA (415 VA)
1 6 694 11 6 694 26 20 A 3P 4P In
1 6 694 12 6 694 27 25 A 1 6 690 00 6 690 20 16 A
1 6 694 13 6 694 28 32 A 1 6 690 01 6 690 21 20 A
1 6 694 14 6 694 29 40 A 1 6 690 02 6 690 22 25 A
1 6 694 15 6 694 30 50 A 1 6 690 03 6 690 23 32 A
1 6 694 16 6 694 31 63 A 1 6 690 04 6 690 24 40 A
1 6 694 17 6 694 32 80 A 1 6 690 05 6 690 25 50 A
1 6 694 18 6 694 33 100 A 1 6 690 06 6 690 26 63 A
1 6 694 19 6 694 34 125 A 1 6 690 07 6 690 27 80 A
1 6 694 20 6 694 35 160 A 1 6 690 08 6 690 28 100 A
1 6 694 21 6 694 36 180 A 1 6 690 09 6 690 29 125 A
1 6 694 22 6 694 37 200 A 1 6 690 10 6 690 30 160 A
1 6 694 23 6 694 38 225 A 1 6 690 11 6 690 31 200 A
1 6 694 24 6 694 39 250 A 1 6 690 12 6 690 32 250 A
Breaking capacity Icu 36 kA (415 VA)
Breaking capacity Icu 36 kA (415 VA)
In
In
1 6 694 40 6 694 55 16 A 1 6 690 40 6 690 60 16 A
1 6 694 41 6 694 56 20 A 1 6 690 41 6 690 61 20 A
1 6 694 42 6 694 57 25 A 1 6 690 42 6 690 62 25 A
1 6 694 43 6 694 58 32 A 1 6 690 43 6 690 63 32 A
1 6 694 44 6 694 59 40 A 1 6 690 44 6 690 64 40 A
1 6 694 45 6 694 60 50 A 1 6 690 45 6 690 65 50 A
1 6 694 46 6 694 61 63 A 1 6 690 46 6 690 66 63 A
1 6 694 47 6 694 62 80 A 1 6 690 47 6 690 67 80 A
1 6 694 48 6 694 63 100 A 1 6 690 48 6 690 68 100 A
1 6 694 49 6 694 64 125 A 1 6 690 49 6 690 69 125 A
1 6 694 50 6 694 65 160 A 1 6 690 50 6 690 70 160 A
1 6 694 51 6 694 66 180 A 1 6 690 51 6 690 71 200 A
1 6 694 52 6 694 67 200 A 1 6 690 52 6 690 72 250 A
1 6 694 53 6 694 68 225 A
1 6 694 54 6 694 69 250 A Breaking capacity Icu 50 kA (415 VA)
Breaking capacity Icu 50 kA (415 VA) In
In 1 6 690 80 6 691 00 16 A
1 6 690 81 6 691 01 20 A
1 6 674 10 6 674 25 16 A 1 6 690 82 6 691 02 25 A
1 6 674 11 6 674 26 20 A 1 6 690 83 6 691 03 32 A
1 6 674 12 6 674 27 25 A 1 6 690 84 6 691 04 40 A
1 6 674 13 6 674 28 32 A 1 6 690 85 6 691 05 50 A
1 6 674 14 6 674 29 40 A 1 6 690 86 6 691 06 63 A
1 6 674 15 6 674 30 50 A 1 6 690 87 6 691 07 80 A
1 6 674 16 6 674 31 63 A 1 6 690 88 6 691 08 100 A
1 6 674 17 6 674 32 80 A 1 6 690 89 6 691 09 125 A
1 6 674 18 6 674 33 100 A 1 6 690 90 6 691 10 160 A
1 6 674 19 6 674 34 125 A 1 6 690 91 6 691 11 200 A
1 6 674 20 6 674 35 160 A 1 6 690 92 6 691 12 250 A
1 6 674 21 6 674 36 180 A
1 6 674 22 6 674 37 200 A
1 6 674 23 6 674 38 225 A
1 6 674 24 6 674 39 250 A

16
DRX 250 HP accessories
TM

0 271 78 6 693 04 0 271 80 0 271 40 0 271 51 0 271 65

Pack Cat.Nos Rotary handles Pack Cat.Nos Control and signalling auxiliaries for
DRX 125, 250, DRX 125 HP and DRX 250 HP
Direct
1 0 271 78 Standard (grey) Auxiliary contact blocks
Vari-depth handle For left-hand side mounting
Up to 250 VA and =
Comprising: connecting rod, bracket,
drilling template, mounting accessories,
1 0 271 40 Block with 1 auxiliary
door locking mechanism
1 0 271 41 Block with 1 alarm
1 0 271 42 Block with 1 auxiliary + 1 alarm
1 0 271 79 Standard (grey)
Shunt trips
Connection accessories 1 0 271 50 12 VA and =
1 0 271 51 24 VA and =
Insulating shields 1 0 271 52 48 VA and =
Used to isolate the connection 1 0 271 53 100/130 VA
between each pole 1 0 271 54 200/277 VA
3P 4P For DRX 125 HP and DRX 250 HP 1 0 271 55 380/480 VA
1 6 693 00 Set of 2 Undervoltage releases
1 6 693 01 Set of 3 1 0 271 60 12 VA and =
Sealable terminal shields 1 0 271 61 24 VA and =
1 6 693 12 6 693 13 Set of 2 1 0 271 62 48 VA and =
1 0 271 68 110 V=
Cage terminals 1 0 271 63 110/130 VA
1 6 693 04 6 693 05 Up to 250 A 1 0 271 64 200/240 VA
Spreaders 1 0 271 67 277 VA
1 6 693 14 6 693 15 Set of incoming or outgoing spreaders 1 0 271 65 380/415 VA
1 0 271 66 440/480 VA
Rear terminals
Used to convert a fixed version with front
terminals into a fixed version with rear
terminals
1 6 693 10 Set of 3 rear terminals
1 6 693 11 Set of 4 rear terminals
Padlock for DRX 125, 250,
DRX 125 HP and DRX 250 HP
1 0 271 80 For locking on "OFF" position
(up to 3 locks)

17
DRX 250 HP
TM
DRX 250 HP adjustable
TM

technical characteristics technical characteristics

n Electrical and mechanical characteristics n Electrical and mechanical characteristics


DRX 250 HP DRX 250 HP DRX 250 HP DRX 250 HP DRX 250 HP DRX 250 HP
25 kA 36 kA 50 kA 25 kA 36 kA 50 kA

Number of poles 3P - 4P 3P - 4P 3P - 4P Number of poles 3P - 4P 3P - 4P 3P - 4P


Release type thermal-magnetic Release type thermal-magnetic

16, 20, 25, 32, 40, 50, 63, 80, 100, 125, 16, 20, 25, 32, 40, 50, 63, 80, 100, 125,
Rated current In (A) Rated current In (A)
160, 180, 200, 225, 250 160, 200, 250

Rated insulation voltage Ui (V) 800 800 800 Rated insulation voltage Ui (V) 800 800 800
Rated operating voltage (50/60 Hz) Ue (V) 550 550 550 Rated operating voltage (50/60 Hz) Ue (V) 550 550 550
Rated impulse withstand Voltage Uimp (kV) 8 8 8 Rated impulse withstand Voltage Uimp (kV) 8 8 8
Rated frequency (Hz) 50 - 60 50 - 60 50 - 60 Rated frequency (Hz) 50 - 60 50 - 60 50 - 60
Reference ambient temperature Tamb (°C) 40 - 50 40 - 50 40 - 50 Reference ambient temperature Tamb (°C) 40 - 50 40 - 50 40 - 50
Operating temperature (°C) -25 to 70 -25 to 70 -25 to 70 Operating temperature (°C) -25 to 70 -25 to 70 -25 to 70
220/240 V± 40 70 90 220/240 V± 40 70 90
380/415 V± 25 36 50 380/415 V± 25 36 50
Rated ultimate short-circuit Rated ultimate short-circuit
breaking capacity Icu (kA) 440/460 V± 20 30 45 breaking capacity Icu (kA) 440/460 V± 20 30 45
IEC 60947-2 IEC 60947-2
480/500 V± 4 4 4 480/500 V± 4 4 4
550 V± 4 4 4 550 V± 4 4 4

Rated service short-circuit breaking capacity Rated service short-circuit breaking capacity
100 100 100 100 100 100
Ics (% Icu) Ics (% Icu)

Rated short-circuit making capacity Icm (kA) Rated short-circuit making capacity Icm (kA)
52.5 75.6 105 52.5 75.6 105
at 415 V± at 415 V±

Neutral protection for 4P version (% Ith) 100 100 100 Neutral protection for 4P version (% Ith) 100 100 100
220/240 V± 40 70 90 220/240 V± 40 70 90
Rated ultimate short-circuit Rated ultimate short-circuit
breaking capacity Icu (kA) 480/500 V± 4 4 4 breaking capacity Icu (kA) 480/500 V± 4 4 4
NEMA AB-1 NEMA AB-1
550 V± 4 4 4 550 V± 4 4 4
Category of use A A A Category of use A A A
Suitable for isolation Yes Yes Yes Suitable for isolation Yes Yes Yes
Thermal adjustment Ir (A) Fixed at 1.0 x In Thermal adjustment Ir (A) 0.8 - 0.9 - 1.0 x In
Fixed : 400 A, for In up to 40 A Adjustable : 400 A, for In up to 40 A
Magnetic adjustment Ii (A) 630 A, for In = 50 / 63 A Magnetic adjustment Ii (A) 6.5 - 10 - 13 x In, for In = 50 A
10 x In, for 80 A ≤ In ≤ 250 A 5 - 7.5 - 10 x In, for 63 A ≤ In ≤ 250 A
mechanical 12000 12000 12000 mechanical 12000 12000 12000
Endurance (cycles) electrical at In 6000 6000 6000 Endurance (cycles) electrical at In 6000 6000 6000
electrical at 0.5 In 6000 6000 6000 electrical at 0.5 In 6000 6000 6000
Neutral protection for 4P version (%) 100 100 100 Neutral protection for 4P version (%) 100 100 100
3P 105 x 165 x 86 3P 105 x 165 x 86
Dimensions W x H x D (mm) Dimensions W x H x D (mm)
4P 140 x 165 x 86 4P 140 x 165 x 86
3P 1.6 3P 1.6
Weight (kg) Weight (kg)
4P 2.05 4P 2.05

18
DRX 250 HP TM

tripping curves

n Curves
Thermal magnetic tripping curve Pass-through specific energy characteristic curve
Icu = 25 / 36 / 50 kA Imax = 250 A 3P - 4P Ue = 415 VA 1010

10 4 I2 t (A2s)

t (s) 109

103 1 108

107 200 A ≤ In ≤ 250 A

102 In = 40 A
li = 10 x ln
125 A ≤ In ≤ 180 A
106
In = 80 A,100 A
10
105
In = 50 A, 63 A

In = 32 A + 50 A
li = 12,5 x ln
104
1
In = 25 A 16 A ≤ In ≤ 40 A
li = 16 x ln
In ≥ 63 A 10 3
li = 5/10 x ln In = 20 A
li = 20 x ln
0,1
In = 16 A 102
li = 25 x ln

0,01 10

1
1 10 102 103 104 105
0,001 Icc (A)
1 10 100 Icc = estimated short circuit symmetrical current (RMS value)
I/Ir I/In
I2t (A2) = pass-through specific energy

t = time
I = rated current
In = rated current
Ir = long time setting current Cut-off peak current characteristic curve (kA)
curve 1 = characteristic with cold start
curve 2 = characteristic with hot start 103

5
4
3

2 2
0.
Ip (kA)

102
25
0.

5
4
3
3 0.

2
5
0.

10 7
0.

8
0.
5
4
3 9
0.
2

1
1 2 3 4 5 10 20 30 40 50 100
Icc (kA)
Icc = estimated short circuit symmetrical current (RMS value)
Ip = maximum short circuit peak current
maximum prospective short circuit peak current
corresponding at the power factor
maximum real peak short circuit current by contact limiting effect

19
DRX 250 HP
TM

dimensions and mounting principle

n Dimensions
3P 4P
105 140 105.4
35 35 17.5 17.5 86
35 35 35
35 35 35 79.5
50 (45)
165
144
126
102

n Mounting principale
Door cut-out Fixing on plate
3P 4P 3P
Y Y 2

126
107 142
52

52

35.5 35.5
37

37

87 Ø3.65 or M4 = =
35

3P 4P 4P
Y Y 2
Y

24 24
52

52

126

5 23
37

37

93
112 35 35

20
DRX 250 HP
TM

dimensions (continued) and connection

n Connection
Connection via busbar
1 - 8 max.

≤ 8

Ø 1 2
≤ 25

≥ 11
≤8

Ø
≤ 25

Connection via cable


With cage terminals Cat.No 6 693 04 (3P) or 6 693 05 (4P)

6 693 04 (3P)
or
DRX 250 HP
6 693 05 (4P)
Flexible
2.5 mm2 _ 120 mm2
CLAC # 14 _ # 250 kcmil
MAX Ø 18 or
3

23
Solid
1 2.5 mm2 _ 150 mm2
# 2 _ # 300 kcmil
1 1
2

2 10 Nm
5

21
DRX 630 TM
DRX 630 adjustable
TM

thermal magnetic MCCBs from 320 to 630 A thermal magnetic MCCBs from 320 to 630 A

0 272 45 0 272 49 6 676 51

Technical characteristics and curves p. 24-25 Technical characteristics and curves p. 24-25

For switching, control, isolation and protection of low-voltage electrical lines For switching, control, isolation and protection of low-voltage electrical lines
Can be fitted with auxiliaries Can be fitted with auxiliaries
Supplied with: Supplied with:
- Screw terminals - Screw terminals
- Fixing screws - Fixing screws
- Insulating shields (2 for 3P and 3 for 4P) - Insulating shields (2 for 3P and 3 for 4P)
Fixed thermal and magnetic Adjustable thermal and magnetic
Conform to IEC 60947-2 Conform to IEC 60947-2
Pack Cat.Nos DRX 630 Pack Cat.Nos DRX 630
Breaking capacity Icu 36 kA (415 VA) Thermal adjustable from 0.8 to 1 x In
3P 4P In Magnetic adjustable from 5 to 10 x In
1 0 272 34 0 272 38 320 A Breaking capacity Icu 36 kA (415 VA)
1 0 272 35 0 272 39 400 A 3P 4P In
1 0 272 36 0 272 40 500 A 1 6 676 50 6 676 54 320 A
1 0 272 37 0 272 41 630 A 1 6 676 51 6 676 55 400 A
Breaking capacity Icu 50 kA (415 VA) 1 6 676 52 6 676 56 500 A
In 1 6 676 53 6 676 57 630 A
1 0 272 42 0 272 46 320 A Breaking capacity Icu 50 kA (415 VA)
1 0 272 43 0 272 47 400 A In
1 0 272 44 0 272 48 500 A 1 6 676 58 6 676 62 320 A
1 0 272 45 0 272 49 630 A 1 6 676 59 6 676 63 400 A
1 6 676 60 6 676 64 500 A
1 6 676 61 6 676 65 630 A

22
DRX 630 accessories
TM

0 262 50 0 262 51 0 262 48 0 263 52 4 222 42 4 222 48

Pack Cat.Nos Rotary handles Pack Cat.Nos Padlock for DRX 630
Direct 1 0 262 40 For locking on "OFF" position
1 0 272 50 Standard (grey) (up to 3 locks)
Vari-depth handle Control and signalling auxiliaries
Comprising: connecting rod, bracket, for DRX 630
drilling template, mounting accessories,
door locking mechanism For DPX3, DPX3 -I and DRX
1 0 272 51 Standard (grey)
Auxiliary contact or fault signal
Connection accessories 1 4 210 11 For signalling the state of
the contacts or opening of
Insulating shields the MCCB on a fault
Used to isolate the connection Changeover switch 3 A - 240 VA
between each pole Shunt releases
0 262 30 Set of 2 pieces Shunt inrrush power 300 VA
3P 4P Sealable terminal shields Coil voltage
1 0 262 44 0 262 45 Set of 2 1 4 222 39 24 VA and =
1 4 222 40 48 VA and =
1 4 222 41 110 VA and =
1 4 222 42 230 VA and =
IP 20 terminal cover 1 4 222 43 400 VA and =
1 4 222 34 4 222 35 Set of two terminal covers
Undervoltage releases
Cage terminals Undervoltage power consumption 5 VA
1 0 262 50 Set of 4 cage terminals for cables
Coil voltage
1 0 262 51 Set of 4 high capacity cage
terminals for cables
1 4 222 44 24 =
1 4 222 45 24 VA
Extended front terminals 1 4 222 46 48 V=
1 0 262 47 Set of 4 extended front terminals 1 4 222 47 110-125 VA
1 4 222 48 220-240 VA
1 4 222 49 380-415 VA
Spreaders
1 0 262 48 0 262 49 Set of incoming or outgoing
spreaders

Swivel terminals
1 0 263 50 0 263 51 Set of incoming or outgoing
swivel terminals

Flat terminals
1 0 263 52 0 263 53 Set of incoming or outgoing
flat terminals

23
DRX 630 TM
DRX 630 adjustable
TM

technical characteristics technical characteristics

n Technical characteristics n Technical characteristics


DRX 630 - 36 kA DRX 630 - 50 kA DRX 630 - 36 kA DRX 630 - 50 kA
Number of poles 3P - 4P 3P - 4P Number of poles 3P - 4P 3P - 4P
Release type thermal-magnetic Releases type thermal-magnetic
Rated current In (A) 320, 400, 500, 630 Rated current In (A) 320, 400, 500, 630
Rated insulation voltage Ui (V) 800 800 Rated insulation voltage (50/60Hz) Ui (V) 800 800
Rated operating voltage (50/60 Hz) Ue (V) 550 550 Rated operational voltage (50/60 Hz) Ue (V) 690 690
Rated impulse withstand Voltage Uimp (kV) 8 8 Rated impulse withstand voltage Uimp (kV) 8 8
Rated frequency (Hz) 50 - 60 50 - 60 Rated frequency (Hz) 50 - 60 50 - 60
Reference ambient temperature Tamb (°C) 40 - 50 40 - 50 Reference ambient temperature Tamb (°C) 40 - 50 40 - 50
Operating temperature (°C) -25 to 70 -25 to 70 Operating temperature (°C) -25 to 70 -25 to 70
110/130 V± 70 100 110/130 V± 70 100
220/240 V± 70 100 220/240 V± 70 100
Rated ultimate short-circuit 380/415 V± 36 50 Rated ultimate short-circuit 380/415 V± 36 50
breaking capacity Icu (kA) breaking capacity Icu (kA)
IEC 60947-2 440/460 V± 30 40 IEC 60947-2 440/460 V± 30 40
480/550 V± 25 30 480/550 V± 25 30
690 V± 14 18 690 V± 14 18

Rated service short-circuit breaking capacity Ics Rated service short-circuit breaking
50 50 100 100
(% Icu) capacity Ics (%Icu)

Rated short-circuit making


Rated short-circuit making capacity Icm (kA) 75.6 105 capacity Icm (at 415 V±) 75.6 105
at 415 V±

Neutral protection for 4P version (% Ith) 100 100 Neutral protection for 4P version (%Ith) 100 100
110/130 V± 18 25 110/130 V± 18 25
220/240 V± 18 25 220/240 V± 18 25
Rated short-circuit breaking 380/415 V± 9 13 Rated short-circuit breaking 380/415 V± 9 13
capacity on IT system Isu.Iit (kA) capacity on IT system Isu.Iit (kA)
IEC 60947-2 (Annexes C - H) 440/460 V± 8 10 IEC 60947-2 (Annexes C - H) 440/460 V± 8 10
480/550 V± 5 6 480/550 V± 5 6
690 V± 4 5 690 V± 4 5
220/240 V± 40 70 220/240 V± 70 100
Rated ultimate short-circuit Rated ultimate short-circuit
breaking capacity Icu (kA) 480/550 V± 4 4 breaking capacity Icu (kA) 480/500 V± 25 30
NEMA AB-1 NEMA AB-1
690 V± 4 5 690 V± 14 18
Category of use A A Category of use A A
Suitable for isolation Yes Yes Suitable for isolation Yes Yes
Thermal adjustment Ir (A) Fixed Thermal adjustment Ir (A) 0.8 ÷ 0.9 ÷ 1 x In
Magnetic adjustment Ii (A) Fixed: 10 x In Magnetic adjustment Ii (A) 5 ÷ 10 x In
mechanical 6000 6000 mechanical 6000 6000
Endurance (cycles) electrical at In 2000 2000 Endurance (cycles) electrical at In 2000 2000
electrical at 0.5 In 4000 4000 electrical at 0.5 In 4000 4000
Neutral protection for 4P version (%) 100 100 3P 140 x 260 x 105
Dimensions W x H x D (mm)
3P 140 x 260 x 105 4P 184 x 260 x 105
Dimensions W x H x D (mm)
4P 183 x 260 x 105 3P 5.20
Weight (kg)
3P 5.20 4P 6.85
Weight (kg)
4P 6.85

24
DRX 630 and DRX 630 adjustable
TM TM

tripping curves

n Curves
DRX 630 Pass-through specific energy characteristic curve
Imax = 630 A from 36 kA to 50 kA 3P - 4P DRX 630 Imax = 630 A from 36 kA to 50 kA 3P - 4P at 415 VA
104 1010

t (s) I t (A2s)
2

109
103

108
102

107

10 1
2

106

1
105

0.1
104

0.01
103

0.001 102
1 10 100
I/Ir I/In
t = time
I = rated current 10
Ir = setting current
curve 1 = characteristic with cold start
curve 2 = characteristic with hot start 1
1 10 102 103 104 105
Icc (A)
Icc = estimated short circuit symmetrical current (RMS value)
I2t (A2s) = pass-through specific energy
Cut-off peak current characteristic curve (kA)
DRX 630 Imax = 630 A from 36kA to 50 kA 3P - 4P
103

5
4
3

2
Ip (kA)

102
25
0.
5
4
3
3 0.

2
5
0.

10 7
0.
8
0.
5
4
9
3 0.

1
1 2 3 4 5 10 20 30 40 50
Icc (kA)
Icc = estimated short circuit symmetrical current (RMS value)
Ip = maximum short circuit peak current
maximum prospective short circuit peak current
corresponding at the power factor
maximum real peak short circuit current by contact limiting effect

25
DRX 630 and DRX 630 adjustable
TM TM

dimensions and mounting principle

n Dimensions
DRX 630 and DRX 630 adjustable
144 Fixing on plate
139.7 183.2 105 4 min.
43.5 43.5 43.5 43.5 43.5 17 50
43.5 43.5 43.5

220
15 max.
90.5

90.5
260

260
220

220

15 max.
104.5 104.5 M5
M5 3P: 43.5
27
4P: 87.0

n Door cut
144
105 4 min.
17
139.7 183.2

15 max.
260

260
93

93
63.5

63.5

41.5 41.5 M5
15 max.

107 107 2.5 max.

Rotary handle-direct on DRX Terminal shields


100 40 58
50
47

391
94

2.5 max.

Rotary handle-vari-depth handle on door


Mounting with flexible seal
132
18.5 105 348 max. 0.8/2
131 min.(1)

62.5

1: 75 mm without mechanical system

26
DRX 630 and DRX 630 adjustable
TM TM

connection

n Connection
Connection via busbar

MAX 32
ø 11
C
MAX 16

2 24 Nm
8

Connection via cable


With cage terminals Cat.No 0 262 50
0 262 50

1
CLAC
1 MAX ø 26

3 2
1

2 24 Nm
8

With high capacity cage terminals Cat.No 0 262 51

MAX ø 22
0 262 51

1
2
1 5

C 2 3 36 Nm
8

4 24 Nm
8

27
FOLLOW US
ALSO ON

EXB18040 - September 2018


www.legrand.com

www.youtube.com/user/legrand
www.facebook.com/Legrand
twitter.com/legrand_news
pinterest.com/legrandgroup

World Headquarters
and International Department
87045 Limoges Cedex - France
Tel. : + 33 (0) 5 55 06 87 87
Fax : + 33 (0) 5 55 06 74 55

You might also like