Professional Documents
Culture Documents
Circuito Tramo Diam. (M) Long. (M) 0.0279 CH A D (.0279CH D)
Circuito Tramo Diam. (M) Long. (M) 0.0279 CH A D (.0279CH D)
ECUACIÓN DE HAZEN-WILLIAMS
Δ𝑄=−
�_𝒊𝒋=𝑳_𝒊𝒋/( 〖 �.𝟐𝟕𝟗𝑪� 〗 _𝒊𝒋
CHW = 130 para acero ^(𝟐.𝟔𝟑) )^𝑵 〖� _𝑖𝑗│𝑄_𝑖𝑗│ 〗
〖� _𝒊𝒋 〗(∑26_1^𝑘▒( ^�_𝑖𝑗= �_
N= 1.851 (𝑁−1) 𝑄_𝑖𝑗 ) )/ 〖𝑄 _𝑖𝑗 〗
(𝑁∑26_1^𝑘▒( 〖� _��│�_��│ 〗 ^(�−1) )
)
Circuito Tramo Diam. (m) Long. (m) D2.63 0.0279*CH (.0279CH*D2.63)N a
I 1-2 0.200 1000 0.01451139 36.27 0.3048215578 3280.61
2-4 0.150 800 0.00680958 36.27 0.0751324699 10647.86
4-3 0.125 500 0.00421574 36.27 0.0309287998 16166.16
3-1 0.200 800 0.01451139 36.27 0.3048215578 2624.49
�_𝒊𝒋=𝑳_𝒊𝒋/( 〖
〖�.𝟐𝟕𝟗𝑪� 〗 _𝒊𝒋
〖� _𝒊𝒋 〗 ^(𝟐.𝟔𝟑) )^𝑵
Δ𝑄=−
(∑26_1^𝑘▒( 〖� _𝑖𝑗│𝑄_𝑖𝑗│ 〗 ^
(𝑁−1) 𝑄_𝑖𝑗 ) )/
(𝑁∑26_1^𝑘▒( 〖� _��│�_��│ 〗 ^(�−1) )
) �_𝑖𝑗= �_𝑖𝑗
〖𝑄 _𝑖𝑗 〗 ^𝑁
Circuito Tramo Diam. (m) Long. (m) a Q (m3/s) H (m) a*│Q│˄N-1
I 1-2 0.200 1000 3280.61 0.03 4.9786 165.9528
2-4 0.150 800 10647.86 0.021 8.3501 397.6225
4-3 0.125 500 16166.16 -0.005 -0.8900 178.0043
3-1 0.200 800 2624.49 -0.02 -1.8804 94.0201
sumatorias 10.5582 835.5997
3.8302
-2.6419
-2.7995
0.8900
-0.7212 0
MÉTODO DE HARDY CROSS PARA EL BALANCE DE PÉRDIDAS
ECUACIÓN DE HAZEN-WILLIAMS
�_𝒊𝒋=𝑳_𝒊𝒋/( 〖
〖�.𝟐𝟕𝟗𝑪� 〗 _𝒊𝒋
〖� _𝒊𝒋 〗 ^(𝟐.𝟔𝟑) )^𝑵
Δ𝑄=−
(∑26_1^𝑘▒( 〖� _𝑖𝑗│𝑄_𝑖𝑗│ 〗 ^
(𝑁−1) 𝑄_𝑖𝑗 ) )/
(𝑁∑26_1^𝑘▒( 〖� _��│�_��│ 〗 ^(�−1) )
) �_𝑖𝑗= �_𝑖𝑗
〖𝑄 _𝑖𝑗 〗 ^𝑁
Circuito Tramo Diam. (m) Long. (m) a Q (m3/s) H (m) a*│Q│˄N-1
I 1-2 0.200 1000 3280.61 0.03 1 4.9786 165.9528
2-4 0.150 800 10647.86 0.021 1 8.3501 397.6225
4-3 0.125 500 16166.16 -0.005 -1 -0.8900 178.0043
3-1 0.200 800 2624.49 -0.02 -1 -1.8804 94.0201
sumatorias 10.5582 835.5997
�_𝒊𝒋=𝑳_𝒊𝒋/( 〖
〖�.𝟐𝟕𝟗𝑪� 〗 _𝒊𝒋
〖� _𝒊𝒋 〗 ^(𝟐.𝟔𝟑) )^𝑵
Δ𝑄=−
(∑26_1^𝑘▒( 〖� _𝑖𝑗│𝑄_𝑖𝑗│ 〗 ^
(𝑁−1) 𝑄_𝑖𝑗 ) )/
(𝑁∑26_1^𝑘▒( 〖� _��│�_��│ 〗 ^(�−1) )
) �_𝑖𝑗= �_𝑖𝑗
〖𝑄 _𝑖𝑗 〗 ^𝑁
Circuito Tramo Diam. (m) Long. (m) a Q (m3/s) H (m) a*│Q│˄N-1
5-4 0.100 20 1470.29 0.007 1 0.1509 21.5566
4-6 0.100 45 3308.14 0.001 1 0.0093 9.2594
I
6-5 0.100 52 3822.74 -0.005 -1 -0.2105 42.0919
sumatorias -0.0503 72.9079
Iteración No. 10
a*Q*│Q│˄N-1 ΔQ (m) Otros Circuitos Q (m3/s) corregido
0.1297 0.0000 0.0000 0.0065
0.0261 0.0000 0.0017
-0.1558 0.0000 -0.0043
0.0000 0.0000
0.2237 0.0000 0.0173
0.0536 0.0000 0.0000 0.0040
-0.0027 0.0000 -0.0007
-0.1297 0.0000 0.0000 -0.0065
-0.1449 0.0000 -0.0147
0.0000 0.0000