Mechanical Dimensions
Supplement to leaflet
Issue 1.00
12.6.2006
Contents
1 TC12-B...........................................................................................................................................3
1.1 Front ...............................................................................................................................................3
1.2 Device dimensions .........................................................................................................................4
1.3 Fitting dimensions ..........................................................................................................................6
2 TC12-S...........................................................................................................................................7
2.1 Front ...............................................................................................................................................7
2.2 Device dimensions .........................................................................................................................8
2.3 Adapter plate................................................................................................................................10
3 TC17-B.........................................................................................................................................11
3.1 Front .............................................................................................................................................11
3.2 Device dimensions .......................................................................................................................12
3.3 Fitting dimensions ........................................................................................................................14
4 TC17-S.........................................................................................................................................15
4.1 Front .............................................................................................................................................15
4.2 Device dimensions .......................................................................................................................16
4.3 Adapter plate................................................................................................................................18
5 Nomenclature .............................................................................................................................19
Table of Figures
Fig. 1-1: TC12-B [Built-In] – Front ...........................................................................................................3
Fig. 1-2: TC12-B [Built-In] – Device dimensions .....................................................................................5
Fig. 1-3: TC12-B [Built-In] – Fitting dimensions ......................................................................................6
Fig. 2-1: TC12-S [Stand-Alone] – Front ..................................................................................................7
Fig. 2-2: TC12-S [Stand-Alone] – Device dimensions ............................................................................9
Fig. 2-3: TC12-S [Stand-Alone] – Adapter plate .................................................................................. 10
Fig. 3-1: TC17-B [Built-In] – Front ........................................................................................................ 11
Fig. 3-2: TC17-B [Built-In] – Device dimensions .................................................................................. 13
Fig. 3-3: TC17-B [Built-In] – Fitting dimensions ................................................................................... 14
Fig. 4-1: TC17-S [Stand-Alone] – Front .............................................................................................. 15
Fig. 4-2: TC17-S [Stand-Alone] – Device dimensions ......................................................................... 17
Fig. 4-3: TC17-S [Stand-Alone] – Adapter plate .................................................................................. 18
Fig. 5-1: Example for type identification ............................................................................................... 19
1 TC12-B
1.1 Front
• TC12-B
Built-In = Built-in unit
• 315 mm x 280 mm
• 12.1" display
280
• Membrane keyboard
- 4 function keys
250 x 188.5
- LED
a bc
315 • Touchscreen
280
272.5
ab
c
15.5
0
-5
0
27
77
TC12-B [Built-In]
280
272.5
248.5
143
39.5
15.5
0
31.5
283.5
157.5
0
7.5
315
307.5
General tolerances
ISO 2768 – mK
302
259
2 TC12-S
2.1 Front
• TC12-S
Stand-Alone = Add-on unit
• 315 mm x 280 mm
• 12.1" display
280
• Membrane keyboard
- 4 function keys
250 x 188.5
- LED
a bc
315 • Touchscreen
280
ab
c
0
0
85
74.3
TC12-S [Stand-Alone]
280
0
0
315
General tolerances
ISO 2768 – mK
100
115
40
100
115 Scale 1:1
Material thickness: 2.5 mm
Fig. 2-3: TC12-S [Stand-Alone] – Adapter plate
Note:
When selecting a housing coupling (an equipment flange) it is to be ensured
that the tube internal diameter is at least 40 mm.
Upon request the adapter plate is provided with holes to mount the particular
flange system.
3 TC17-B
3.1 Front
• TC17-B
Built-In = Built-in unit
• 410 mm x 370 mm
• 17.0" display
• Membrane keyboard
370
- 4 function keys
- LED
• 2 x USB under covering
341 x 273.5 • Touchscreen
a bc
410
Fig. 3-1: TC17-B [Built-In] – Front
370
362.5
ab
c
16.5
0
-5
0
34
84
TC17-B [Built-In]
370
362.5
338.5
188.5
40.5
16.5
0
205
31.5
378.5
0
7.5
410
402.5
General tolerances
ISO 2768 – mK
397
348
4 TC17-S
4.1 Front
• TC17-S
Stand-Alone = Add-on unit
• 410 mm x 370 mm
• 17.0" display
• Membrane keyboard
370
- 4 function keys
- LED
• 2 x USB under covering
341 x 273.5 • Touchscreen
a bc
410
Fig. 4-1: TC17-S [Stand-Alone] – Front
370
ab
c
0
0
95
84.3
TC17-S [Stand-Alone]
370
0
0
410
General tolerances
ISO 2768 – mK
100
115
40
100
115 Scale 1:1
Material thickness: 2.5 mm
Fig. 4-3: TC17-S [Stand-Alone] – Adapter plate
Note:
When selecting a housing coupling (an equipment flange) it is to be ensured
that the tube internal diameter is at least 40 mm.
Upon request the adapter plate is provided with holes to mount the particular
flange system.
5 Nomenclature
For example:
TC 12 -S /Win /WLAN
Option
Use
Mounting
Display version
Basic system