H

HP SONOS 2000
Imaging System

Technical Data
Obtaining diagnostic
information more efficiently

Features
Stress Echo option assures rapid
acquisition, editing, and display
of full-resolution images in quad-
screen format, based on user-
selected protocols.
Dynamic Elevation Beamform-
ing and new HP transducers
produce exceptional 2-D images
throughout the field of view.
QuickTouch user interface
allows quick, consistent, and
reliable navigation between all
imaging modes and controls for
more efficient exams.
Digital Network Interface lets
you network your SONOS studies
to EnConcert. You can quickly
and easily capture and store
original quality images as true dig-
ital data.
Extended Definition Color
Flow displays exceptional filling
and physiologic flow presentation.
Multi, dual and single-fre-
quency transducers from 2.0
MHz to 7.5 MHz cover a wide range
of cardiac/vascular applications. Superior 2-D imaging provides Vascular Improvement Pack-
versatility over a wide range of age helps you achieve optimum
Steerable PW/CW Doppler patients and pathologies, showing studies — from carotid to deep
provides excellent penetration fine textures and focused anat- venous and abdominal vascular —
and sensitivity. omy. through improved B-mode and
HP presets automatically config- color Doppler, new multi-
ure the system to the way you frequency transducers, a new
want to perform an exam. analysis package, and innovative
features that increase your
efficiency.
Features Functional Description Specifications

Special features for pediatric The HP SONOS 2000 is a high-res- M2406A Option A01
imaging include specialized trans- olution, real-time phased array SONOS 2000 Imaging System
ducers for superior image quality; ultrasound scanner with built-in
Fetal Doppler; and High Pulse applications and presets for M2407A SONOS 2000 Upgrade
Repetition Frequency (HPRF) adult and pediatric cardiac
Doppler, which accurately mea- imaging as well as vascular and Standard Applications
sures range-specific, high-velocity abdominal studies. It is designed – Cardiac (adult and pediatric)
flow. to help the user obtain diagnostic – Vascular
information in a more efficient – Abdominal
Continuous Loop Review
manner.
option allows review of 2-D and
HP Exam-Type Presets:
color images at various speeds, The SONOS 2000 performs 2-D,
Cardiac
in single-, dual-, or quad-screen M-mode, steerable pulsed- and
– Adult
format. continuous-wave Doppler, High
– Pediatric
Definition Color Flow, and con- – TEE
Digital Storage and Retrieval
ventional color flow imaging. A
option archives images on an – Plus 9 customizable presets*
variety of display formats, includ-
optical disk for high-capacity
ing the optional, fully-integrated
storage and rapid access to Vascular
quad screen Continuous Loop
studies. – Carotid
Review (CLR), provide versatility
– Vascular Transcranial Doppler
Lateral Gain Control adds an in reviewing and comparing
(TCD)
additional level of flexibility to images.
– Upper Ext. Venous
image quality control and opti- – Lower Ext. Venous
mizes detection of blood/tissue – Upper Ext. Arterial
interfaces. – Lower Ext. Arterial
Tilt-and-swivel monitor allows – Vascular TCD- TO
easy viewing in a variety of – Plus 5 customizable presets*
scanning environments.
Abdominal
Backlit control panel with – Abdominal
adjustable intensities permits – Vascular Abdominal
operation in dimly lit rooms. – Renal
– Small Parts
Extended physio option pro-
– Plus 8 customizable presets*
vides ECG, auxiliary, respiration,
heartsound, and pulse waveform
Imaging Modes
monitoring.
– 2-D
– M-mode
– Color flow
– Steerable PW/CW Doppler

Additional Standard Features


– Extended High Definition
Color Flow
– LGC
– Cardiac and vascular analysis
– HP Colorization
– 1.9 MHz non-imaging Doppler
transducer
– ECG/AUX
– S-VHS VCR (PAL)
Options Dedicated Imaging Tuning – Gain save feature integrated
– Continuous Loop Review Controls into all stage protocols
(CLR) – Gain: 0-100% continuous rotary – Archiving performed with HP
– Digital Storage and Retrieval control Digital Storage and Retrieval
(DSR) – Compress: 0-100% continu- (DSR) optical disk
– Digital Network Interface ous rotary control – Increased 128-megabyte
– Extended Physio module – Depth: 2-24 cm for cardiac Continuous Loop Review
presets**, 1-24 cm for vascular memory allows storage of
Localization Options: and abdominal presets** 249 b/w or 124 color loops
– TGC: 8 horizontal slide pots (R-waves)
Languages – LGC: 8 vertical slide pots – Stage and view data are auto-
– English, French, German, – Volume: 1 horizontal slide pot matically entered into the disk
Italian, Spanish file for each stress exam
Dedicated Hardcopy Controls – For on-line review, a stress
Video Format – Tape study and all associated files
– 60 Hz NTSC – Acquire can be accessed on the SONOS
– 50 Hz PAL – Print imaging system with full access
– Freeze to editing controls for loop
Line Voltage speed, freeze, scroll, and loop
– 100, 120, 220, 230, 240 Dedicated Trackball Controls edit and synchronization/align-
– Continuous x/y control of ment
Power Cords screen cursors – For off-line review, stored digi-
– Australia, Denmark, North – Positioning: 2-D, Zoom or tal information on optical disk
America, South Africa, color flow is compatible with leading off-
Switzerland, United Kingdom, – Sizing: 2-D, Zoom or color flow line cardiology analysis work-
Western Europe – Caliper stations
– Trace
System Mode Keys – Erase Continuous Loop Review
– Loop Display – Enter (CLR) Option
– Disk Image – Format: full-, split-, and
– VCR Play Stress Echo Option quad-screen
– Analysis Report – Four standard imaging views; – 64-frame memory for 2-D
order of acquisition is stage imaging
Dedicated System Controls dependent – 32-frame memory for
– Reset – Hard-key, touch panel, or color flow
– Test foot-switch controls for image – Up to 256 frames stored in
– Setup acquisition quad-screen mode
– Patient ID – Single-, quad-, and multi-cycle – Acquisition of real-time or
acquisition standard for all VCR images
Dedicated Imaging Controls stages – QuickReview mode for track-
– 2-D – Multi-cycle (continuous) ball scroll-through of most
– M-mode acquisition mode available recently-acquired full-screen
– Color flow during peak stage 2-D or color images
– Steerable PW/CW Doppler – Three available protocols:
2-stage; 3-stage; 4-stage

* You can use up to a total of 10


customizable presets at one time.
Digital Storage and Retrieval – Displayed on image screen – Operates in parallel with keys
(DSR) Option on control panel
– Store, retrieve, and review Recording Devices:
looped or still frame 2-D, – Super-VHS VCR, NTSC or PAL Color Monitor
M-Mode, Doppler, and color (standard) – 12’’ (30 cm) high resolution
flow images from CLR memory – Digital Storage and Retrieval shadow mask CRT
(DSR) – Minimum of 640 dots per line;
Digital Network Interface – Color Printer (large or small) 0.28 mm dot pitch
Option NTSC or PAL – Monitor swivel: ± 120 degrees
– Provides a network connec- – Black & White Printer (large or – Monitor tilt: ± 10 degrees
tion to EnConcert, making the small format) NTSC or PAL – Brightness and contrast
“digital lab” a reality – Strip Chart Recorder controls
– True digital, non-digitized echo
images Inputs/Outputs: System Dimensions:
– Store 2-D, color flow, calibra-
tion, AQ information and R,G,B, and Synch Length and Width
patient identification as well as – Output to external RGB – Overall length: 43” (109 cm)
grayscale and color images monitor or printer – Width: 24.5” (62 cm)
– Ground clearance: 3” (8 cm)
Custom Measurements and S-Video
Calculations – Output to external S-Video Height
(Analysis Functions) monitor, VCR or printer – Top of monitor: 57” (145 cm)
– Mode- and preset-driven – Front handle: 36” (92 cm)
– Measurements can be made B/W
from 2-D, M-mode, PW/CW – Output to external monitor, Wheel Base
Doppler, CLR, DSR still frame, VCR or printer – Swivel casters pivoted inward:
VCR playback, and frozen 20.5” (52 cm)
images ECG – Swivel casters pivoted
– ECG output or R-wave outward: 25.5” (65 cm)
Acoustic Output Display trigger out
– Complies with the AIUM/ Wheels
NEMA Output Display Audio L, R – 8” (20 cm) diameter
Standard – Output to external VCR or – Spring suspension on both
monitor with stereo speakers fixed axle and swivel casters
Four Power Indexes
– MI (Mechanical Index) Print Weight
– TIS (Thermal Soft Tissue – Output to control external – 478 lb (218 kg)
Index) printer Configured with VCR and large
– TIB (Thermal Bone Index) – Available only if less than 2 format color printer.
– TIC (Thermal Cranial Bone internal printers
Index) Heat Dissipation
– Values shown in 0.1 incre- Foot Switch Port – 1200 watts maximum
ments – Input for control of Tape, – 4100 BTUs/hour
Print, and Freeze

** 1 cm increments.
H

For more information, contact your local


HP sales office or nearest regional office:
United States:
Hewlett-Packard Company
Medical Products Group Headquarters
3000 Minuteman Road
Andover, MA 01810
(508) 687-1501
IMAGING SYSTEMS
Medical Customer Information
1-800-934-7372
Canada:
Hewlett-Packard (Canada) Ltd.
5150 Spectrum Way
Mississauga, Ontario L4W 5G1
(905) 206-4725
Latin America:
Hewlett-Packard Latin America
5200 Blue Lagoon Drive
9th Floor
Miami, FL 33126
(305) 267-4220
Marketing Center Europe:
Hewlett-Packard GmbH
Schickardstr. 4
71034 Boeblingen
Germany
(+49) 7031 14 5151
Asia Pacific Headquarters:
Hewlett-Packard Asia-Pacific, Ltd.
17-21/F Shell Tower, Times Square
1 Matheson Street, Causeway Bay
Hong Kong
(+852) 2599 7777
Australia:
(A.C.N. 004 394 763)
(+61 3) 9210 5448
China/Northeast Asia:
(86 10) 505 3888
India:
(+91 11) 682 6000
Japan:
(+81 3) 3335-8154
Korea:
(+82 2) 769-0114
Singapore/Southeast Asia/South Asia:
(+65) 275-3888
Taiwan:
(886 2) 712-0404

Copyright © 1997
The information contained in this docu- Caution: In the U.S. federal law Hewlett-Packard Company
ment is subject to change without notice. restricts this device to sale on the order
of a physician. Printed in U.S.A. 4/97
HP Imaging Systems Division is certi- 5965-1261E Revision B.2
fied to ISO 9001, an internationally
recognized standard for quality systems. recycled paper

You might also like