Anexo 2 - Essential Led Tube 16w830 g5 I MX

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Lighting

Essential LED tubes


T5 Mains
ESSENTIAL LEDtube 1200mm 16W830 G5 I MX
The Essential LEDtube T5 is an affordable LED solution suitable for replacing T5
fluorescent lamps. Thanks to a unique design, Philips Essential LED tube T5 Mains
can be directly installed in luminaires operating on mains power connection.The
product provides a natural lighting effect for use in general lighting applications, as
well as instant energy savings – an environmentally friendly solution.

Product data

General Information Starting Time (Nom) 0.5 s

Cap-Base G5 [ G5] Warm Up Time to 60% Light (Nom) 0.5 s

Nominal Lifetime (Nom) 30000 h Power Factor (Nom) 0.92

Switching Cycle 50000X Voltage (Nom) 100-240 V

B50L70 30000 h

Temperature
Light Technical T-Ambient (Max) 45 °C

Color Code 830 [ CCT of 3000K] T-Ambient (Min) -20 °C

Luminous Flux (Nom) 2000 lm T-Storage (Max) 65 °C

Luminous Flux (Rated) (Nom) 2000 lm T-Storage (Min) -40 °C

Correlated Color Temperature (Nom) 3000 K T-Case Maximum (Nom) 70 °C

Color Consistency <6

Color Rendering Index (Nom) 80 Controls and Dimming


LLMF At End Of Nominal Lifetime (Nom) 70 % Dimmable No

Operating and Electrical Mechanical and Housing


Input Frequency 50 to 60 Hz Product Length 1200 mm

Power (Rated) (Nom) 16 W

Lamp Current (Max) 175 mA Approval and Application


Lamp Current (Min) 70 mA Energy Efficiency Label (EEL) A+

Datasheet, 2019, April 2 data subject to change


Essential LED tubes T5 Mains

Energy Saving Product Yes Order code 929001380912

Approval Marks CE marking RoHS compliance KEMA Keur Numerator - Quantity Per Pack 1

certificate Numerator - Packs per outer box 20

Material Nr. (12NC) 929001380912


Product Data Net Weight (Piece) 0.180 kg

Full product code 871869673416200

Order product name ESSENTIAL LEDtube 1200mm 16W830 G5 I MX

EAN/UPC - Product 8718696734162

Dimensional drawing

A3 Product D1 D2 A1 A2 A3

ESSENTIAL LEDtube 1200mm 15.8 mm 19 mm 1149 mm 1156.1 mm 1163.2 mm

A2 16W830 G5 I MX

A1
D1
D2

TLED 1200mm 100-240V 16-28W 3000K

Photometric data

General Uniform Lighting 100


1 x TLED 16W 3000K 240D 9290013809
Intensity (%)

1 x 2000 lm

Polaro intensityo diagramo Quantity estimation diagram UGR diagram


150 180 150 nr. of luminaires

80
16.0
100 hroom: 2.8 m hroom : 2.8 m
Reflectances: 0.70, 0.50, 0.20 Refl: 0.70 0.50 0.20
75 Maintenance factor: 1.0 m 19
120 Ceiling mounted
120o 120o Ceiling mounted
50 10
12.0 19 : viewed endwise

25 90 Y : viewed crosswise
13
750 lx
90o 90o Y : Parallel to viewing dir.

25 60
500 lx 8.0
60o 50 60o
300 lx 16
30
75
γ 10
100 4.0
0
(cd/1000lm) 0o 10 30 50 70 90 (m2) 4.0 8.0 12.0 m 16.0
X
0-180o 90-270o
Utilisation factor table Luminance Table

60
Light output ratio 0.49
Service upward 0.14 Reflectances (%) for ceiling, walls and working plane (CIE) Plane 0.0 15.0 30.0 45.0 60.0 75.0 90.0
Room Cone
Service downward 0.35 0.80 0.80 0.70 0.70 0.70 0.70 0.50 0.50 0.30 0.30 0.00
45.0 428 453 502 589 703 861 1063
Index 0.50 0.50 0.50 0.50 0.50 0.30 0.30 0.10 0.30 0.10 0.00
50.0 383 410 467 567 696 875 1122
CIE flux code 34 62 83 72 49 k 0.30 0.10 0.30 0.20 0.10 0.10 0.10 0.10 0.10 0.10 0.00
55.0 335 367 435 550 694 899 1192
60.0 285 325 406 533 695 928 1291
UGRcen (4Hx8H, 0.25H) 19 0.60 0.19 0.18 0.18 0.18 0.17 0.14 0.13 0.10 0.12 0.10 0.08
0.80 0.24 0.22 0.23 0.22 0.21 0.17 0.16 0.14 0.15 0.12 0.10 65.0 235 280 377 518 699 970 1418
1.00 0.28 0.26 0.26 0.25 0.24 0.21 0.19 0.16 0.17 0.15 0.12 70.0 180 234 350 509 712 1027 1596
1.25 0.31 0.29 0.30 0.29 0.27 0.24 0.22 0.19 0.20 0.18 0.15 75.0 121 193 328 504 733 1102 1859
1.50 0.34 0.31 0.32 0.31 0.30 0.26 0.24 0.22 0.22 0.20 0.16 80.0 65 155 308 503 761 1206 2280
2.00 0.39 0.35 0.37 0.35 0.33 0.30 0.27 0.25 0.25 0.23 0.19
85.0 18 126 296 510 802 1354 3058
2.50 0.42 0.37 0.40 0.37 0.36 0.33 0.30 0.28 0.27 0.25 0.21
3.00 0.44 0.39 0.42 0.39 0.37 0.35 0.32 0.30 0.29 0.27 0.23 90.0 4 109 291 525 865 1579 4938
2
4.00 0.48 0.41 0.45 0.42 0.39 0.37 0.34 0.32 0.31 0.30 0.25 (cd/m )
5.00 0.50 0.43 0.46 0.43 0.41 0.39 0.35 0.34 0.32 0.31 0.26

Ceiling mounted
2017-03-30

40

20

0
200 300 400 500 600 700 800
CalcuLuX Photometrics 4.5 Philips Lighting B.V. Page: 1/1
[nm]

ESSENTIAL LEDtube 16W G5 830 APR ESSENTIAL LEDtube 16W G5 830 APR

150o
o
180 150o
100
75
120o 120o
50
25
90o 90o

25

60o 50 60o
75
100
(cd/1000lm) 0o
0-180o 90-270o

ESSENTIAL LEDtube 16W G5 830 APR

Datasheet, 2019, April 2 2 data subject to change


Essential LED tubes T5 Mains

Lifetime

60000 80

Failure rate in %
70
50000
60 65
Life time (Hours)

40000 50
B10L70 40 75
30000
30
20000 85
B50L70 20
10000 10
0
0 0 10000 20000 30000 40000
55 60 65 70 75 80 85 Time (hours)
Tc(°C)

ESSENTIAL LEDtube 8-16W G5 830-865 APR ESSENTIAL LEDtube 8-16W G5 830-865 APR

100 100

Lumen in %
Failure rate in %

80 95
90
60
85
40 80
20 75
70
0 0 10000 20000 30000 40000 50000
0 10000 20000 30000 40000 50000 60000
Burning hours
Time (hours)

ESSENTIAL LEDtube 8-16W G5 830-865 APR ESSENTIAL LEDtube 8-16W G5 830-865 APR

100%

98%
Lumen (%)

96%

94%

92%
65 70 75 80 85
Tc(°C)

ESSENTIAL LEDtube 16W G5 830-865 APR

Datasheet, 2019, April 2 3 data subject to change


Essential LED tubes T5 Mains

© 2019 Signify Holding All rights reserved. Signify does not give any representation or warranty as to the accuracy or

completeness of the information included herein and shall not be liable for any action in reliance thereon. The

information presented in this document is not intended as any commercial offer and does not form part of any

quotation or contract, unless otherwise agreed by Signify. Philips and the Philips Shield Emblem are registered www.lighting.philips.com

trademarks of Koninklijke Philips N.V. 2019, April 2 - data subject to change

You might also like